Search Results

Search found 2299 results on 92 pages for 'alec smart'.

Page 22/92 | < Previous Page | 18 19 20 21 22 23 24 25 26 27 28 29  | Next Page >

  • Configure autocomplete in intellij with hamcrest and mockito dsl

    - by sgargan
    I'm wondering if its possible to configure Intellij's smart insert to suggest hamcrest and mockito dsl idioms when in test classes. Really I'm looking for something like eclipse's 'static favorites', so that when I hit ctrl + space or ctrl +shift +space the idioms are present. In general is it possible to configure autocomplete/smart insert or the suggestions balloon for that matter. I've looked through the settings without much luck but could easily have overlooked something.

    Read the article

  • Multiple data centers and HTTP traffic: DNS Round Robin is the ONLY way to assure instant fail-over?

    - by vmiazzo
    Hi, Multiple A records pointing to the same domain seem to be used almost exclusively to implement DNS Round Robin as a cheap load balancing technique. The usual warning against DNS RR is that it is not good for high availability. When 1 IP goes down clients will continue to use it for minutes. A load balancer is often suggested as a better choice. Both claims are not completely true: When the traffic is HTTP then, most of the HTML browsers are able to automatically try the next A record if the previous is down, without a new DNS look-up. Read here chapter 3.1 and here. When multiple data centers are involved then, DNS RR is the only option to distribute traffic across them. So, is it true that, with multiple data centers and HTTP traffic, the use of DNS RR is the ONLY way to assure instant fail-over when one data center goes down? Thanks, Valentino Edit: Off course each data center has a local Load Balancer with hot spare. It's OK to sacrifice session affinity for an instant fail-over. AFAIK the only way for a DNS to suggest a data center instead of another is to reply with just the IP (or IPs) associated to that data center. If the data center becomes unreachable then all those IP are also unreachables. This means that, even if smart HTML browsers are able to instantly try another A record , all the attempts will fail until the local cache entry expires and a new DNS lookup is done, fetching the new working IPs (I assume DNS automatically suggests to a new data center when one fail). So, "smart DNS" cannot assure instant fail-over. Conversely a DNS round-robin permits it. When one data center fail, the smart HTML browsers (most of them) instantly try the other cached A records jumping to another (working) data center. So, DNS round-robin doesn't assure session affinity or the lowest RTT but seems to be the only way to assure instant fail-over when the clients are "smart" HTML browsers. Edit 2: Some people suggest TCP Anycast as a definitive solution. In this paper (chapter 6) is explained that Anycast fail-over is related to BGP convergence. For this reason Anycast can employ from 15 minutes to 20 seconds to complete. 20 seconds are possible on networks where the topology was optimized for this. Probably just CDN operators can grant such fast fail-overs. Edit 3:* I did some DNS look-ups and traceroutes (maybe some expert can double check) and: The only CDN using TCP Anycast seems to be CacheFly, other operators like CDN networks and BitGravity use CacheFly. Seems that their edges cannot be used as reverse proxies. Therefore, they cannot be used to grant instant failover. Akamai and LimeLight seems to use geo-aware DNS. But! They return multiple A records. From traceroutes seems that the returned IPs are on the same data center. So, I'm puzzled on how they can offer a 100% SLA when one data center goes down.

    Read the article

  • Bye Bye Year of the Dragon, Hello BPM

    - by Ajay Khanna
    Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} As 2012 fades and we usher in a New Year, let’s look back at some of the hottest BPM trends and those we’ll be seeing more of in the coming months. BPM is as much about people as it is about technology. As people adopt new ways of engagement, new channels of communications and new devices to interact , the changes are reflected in BPM practices. As Social and Mobile have become an integral part of our personal and professional lives, we’ll see tighter integration of social and mobile with BPM, and more use cases emerging for smarter process management in 2013. And with products and services becoming less differentiated, organizations will strive to differentiate on Customer Experience. Concepts like Pace Layered Architecture and Dynamic Case Management will provide more flexibility and agility to IT groups and knowledge workers. Take a look at some of these capabilities we showcased (see video) at Oracle OpenWorld 2012. Some of these trends that will continue to gain momentum in 2013: Social networks and social media have provided a new way for businesses to engage with customers. A prospect is likely to reach out to their social network before making any purchase. Companies are increasingly engaging with customers in social networks to influence their purchasing decisions, as well as listening to customers via tools like sentiment analysis to see what customers think about a particular product or process. These insights are valuable as companies look to improve their processes. Inside organizations, workers are using social tools to engage with each other to design new products and processes. Social collaboration tools are being used to resolve issues where an employee needs consultation to reach a decision. Oracle BPM Suite includes social interaction as an integral part of its process design and work management to empower today’s business users. Ubiquitous smart mobile devices are trending as a tool of choice for many workers. Many companies are adopting the policy of “Bring Your Own Device,” and the device of choice is a tablet. Devices like smart phones and tablets not only provide mobility to workers and customers, but they also provide additional important information – the context. By integrating the mobile context (location, photos, and preferences) into your processes, organizations can make much more informed decisions, as well as offer more personalized service to customers. Using Oracle ADF Mobile, you can easily create user interfaces for mobile devices and also capture location data for process execution. Customer experience was at the forefront of trending topics in 2012. Organizations are trying to understand their customers better and offer them more personalized and differentiated services. Customer experience is paramount when companies design sales and support processes. Companies are looking to BPM to consistently and efficiently orchestrate customer facing processes across disparate systems, departments and channels of communication. Oracle BPM Suite provides just the right capabilities for organizations to design and deliver an excellent customer experience. Pace Layered Architecture strategy is gaining traction as a way to maximize agility and minimize disruption in organizations. It provides a framework to manage the evolution of your information system when different pieces of it are changing at different rates and need to be updated independent of one another. Oracle Fusion Middleware and Oracle BPM Suite are designed with this in mind. The database layer, integration layer, application layer, and process layer should not be required to change at the same time. Most of the business changes to policy or process can be done at the process layer without disrupting the whole infrastructure. By understanding the type of change needed at a particular level, organizations can become much more agile and efficient. Adaptive Case Management proposes more flexibility to manage processes or cases that do not follow a structured process flow. In such situations, the knowledge worker managing the case needs to evaluate what step should occur next because the sequence of steps can’t be predetermined. Another characteristic is that it requires much more collaboration than straight-through process. As simple processes become automated, and customers adopt more and more self-service, cases that reach the case workers are much more complex and need more investigation. Oracle BPM suite includes comprehensive adaptive case management capability to manage such unstructured and complex processes. Smart BPM or making your BPM intelligent has been the holy grail for BPM practitioners who imagined that one day BPM would become one with Business Intelligence, Business Activity Monitoring and Complex Event Processing, making it much more responsive and helpful in organizational decision making. In 2013, organizations will begin to deploy these intelligent BPM solutions. Oracle offers an integrated solution that brings together the powerful functionality of BI, BAM, event processing, and Real Time Decisions to help organizations create smart process based solutions. In order to help customers reach their BPM goals faster and remove risks associated with BPM initiatives, Oracle has introduced Oracle Process Accelerators, pre-built best practices applications built on Oracle BPM Suite that are fully production grade and ready to deploy. These are exiting times for BPM practitioners and there is so much to look forward to in 2013. We wish you a very happy and prosperous New Year 2013. Happy BPMing!

    Read the article

  • CodePlex Daily Summary for Monday, September 03, 2012

    CodePlex Daily Summary for Monday, September 03, 2012Popular ReleasesMetodología General Ajustada - MGA: 03.01.03: Cambios Aury: Ajuste del margen del reporte. Visualización de la columna de Supuestos en la parte del módulo de Decisión. Cambios John: Integración de código con cambios enviados por Aury Niño. Generación de instaladores. Soporte técnico por correo electrónico y telefónico.Iveely Search Engine: Iveely Search Engine (0.2.0): ????ISE?0.1.0??,?????,ISE?0.2.0?????????,???????,????????20???follow?ISE,????,??ISE??????????,??????????,?????????,?????????0.2.0??????,??????????。 Iveely Search Engine ?0.2.0?????????“??????????”,??????,?????????,???????,???????????????????,????、????????????。???0.1.0????????????: 1. ??“????” ??。??????????,?????????,???????????????????。??:????????,????????????,??????????????????。??????。 2. ??“????”??。?0.1.0??????,???????,???????????????,?????????????,????????,?0.2.0?,???????...Thisismyusername's codeplex page.: HTML5 Mulititouch Fruit Ninja Proof of Concept: This is an example of how you could create a game such as Fruit Ninja using HTML5's multitouch capabilities. Sorry this example doesn't have great graphics. If I had my own webpage, I could store some graphics and upload the game there and it might look halfway decent, but since I'm only using a Codeplex page and most mobile devices can't open .zip files, the fruits are just circles. I hope you enjoy reading the source code anyway.GmailDefaultMaker: GmailDefaultMaker 3.0.0.2: Add QQ Mail BugfixSmart Data Access layer: Smart Data access Layer Ver 3: In this version support executing inline query is added. Check Documentation section for detail.TSQL Code Smells Finder: POC 1.01: Proof of concept 1.01 TSQLDomTest.ps1 and Errors.Txt are requiredConfuser: Confuser build 76542: This is a build of changeset 76542.Reactive State Machine: ReactiveStateMachine-beta: TouchStateMachine now supports Microsoft Surface 2.0 SDK. The TouchStateMachine is an extension to the Reactive State Machine. Reactive State Machine uses NuGet for dependency managementSharePoint Column & View Permission: SharePoint Column and View Permission v1.2: Version 1.2 of this project. If you will find any bugs please let me know at enti@zoznam.sk or post your findings in Issue TrackerMihmojsos OS: Mihmojsos OS 3 (Smart Rabbit): !Mihmojsos OS 3 Smart Rabbit Mihmojsos Smart Rabbit is now availableDotNetNuke Translator: 01.00.00 Beta: First release of the project.YNA: YNA 0.2 alpha: Wath's new since 0.1 alpha ? A lot of changes but there are the most interresting : StateManager is now better and faster Mouse events for all YnObjects (Sprites, Images, texts) A really big improvement for YnGroup Gamepad support And the news : Tiled Map support (need refactoring) Isometric tiled map support (need refactoring) Transition effect like "FadeIn" and "FadeOut" (YnTransition) Timers (YnTimer) Path management (YnPath, need more refactoring) Downloads All downloads...Audio Pitch & Shift: Audio Pitch And Shift 5.1.0.2: fixed several issues with streaming modeUrlPager: UrlPager 1.2: Fixed bug in which url parameters will lost after paging; ????????url???bug;Sofire Suite: Sofire v1.5.0.0: Sofire v1.5.0.0 ?? ???????? ?????: 1、?? 2、????EntLib.com????????: EntLib.com???????? v3.0: EntLib eCommerce Solution ???Microsoft .Net Framework?????????????????????。Coevery - Free CRM: Coevery 1.0.0.24: Add a sample database, and installation instructions.Math.NET Numerics: Math.NET Numerics v2.2.1: Major linear algebra rework since v2.1, now available on Codeplex as well (previous versions were only available via NuGet). Since v2.2.0: Student-T density more robust for very large degrees of freedom Sparse Kronecker product much more efficient (now leverages sparsity) Direct access to raw matrix storage implementations for advanced extensibility Now also separate package for signed core library with a strong name (we dropped strong names in v2.2.0) Also available as NuGet packages...Microsoft SQL Server Product Samples: Database: AdventureWorks Databases – 2012, 2008R2 and 2008: About this release This release consolidates AdventureWorks databases for SQL Server 2012, 2008R2 and 2008 versions to one page. Each zip file contains an mdf database file and ldf log file. This should make it easier to find and download AdventureWorks databases since all OLTP versions are on one page. There are no database schema changes. For each release of the product, there is a light-weight and full version of the AdventureWorks sample database. The light-weight version is denoted by ...Christoc's DotNetNuke Module Development Template: DotNetNuke Project Templates V1.1 for VS2012: This release is specifically for Visual Studio 2012 Support, distributed through the Visual Studio Extensions gallery at http://visualstudiogallery.msdn.microsoft.com/ After you build in Release mode the installable packages (source/install) can be found in the INSTALL folder now, within your module's folder, not the packages folder anymore Check out the blog post for all of the details about this release. http://www.dotnetnuke.com/Resources/Blogs/EntryId/3471/New-Visual-Studio-2012-Projec...New ProjectsBPVote4PPT: BPVote For PowerPointCosmo OS: La semplicità in un OSFinancial Analytic Tools: C#.Net Financial Analytic ToolsGeminiMVC: An Open Source CMS written in ASP.net MVC 4 with speed, extensibility, and ease-of-us in mind.JQuery SharePoint Autocomplete People Picker: This JQUery bundle provides an autocomplete people picker based on SharePoint profiles. It can be hosted on the SharePoint itself or on remote applications.Kerbal Space Program PartModule Library: This project is designed to add various functionalities to custom parts for the space program simulation game Kerbal Space Program.KeyboardRemapper: This tool to remaps keys in the keyboard. If you have more than one keyboard or an additional keypad, you can remap the keys of the each keyboard independentlyKHStudent: ??????Localized DataAnnotations with T4 templates: Simplified DataAnnotations localization using T4 templates.MfcLightToolkit: Supports development for small and simple MFC application. Provides asynchronous programming model like .NET, file download, easy control resizing, and so on.Müslüm ÖZTÜRK Code Lib: Test amaçli olusturulan projemdirPolska: Testproject in how a polish grammerprogram can look like.QueueLessApp: Here is the codeRusIS.CMS: aaaSGPS: Projeto de controle de produtos e serviçosStemmersNet: Stemmers pack for .Net FrameworkTrabajo Final de Ingenieria - Javier Vallejos: Tesis Final de la carrera de Ingenieria - Universidad Abierta Interamericana.TSQL Code Smells Finder: TSQL 'smells' findersXNA and Data Driven Design: This project includes links for XNA and Data Driven DesignXNA and System Testing: This project includes code for XNA and System TestingYUGI-AR Project: an open source project for yugioh based augmented reality???????? ? ?????????????: ???? ??????? ??????? ?????????????? ??????????? ?????????? ??? ? ????? ?????? ? ? ??? ??? ????? ? ??? ?????????? ????????????.

    Read the article

  • Is Microsoft&rsquo;s Cloud Bet Placed on the Ground?

    - by andrewbrust
    Today at the Unversity of Washington, Steve Ballmer gave a speech on Microsoft’s cloud strategy.  Significantly, Azure was only briefly mentioned and was not shown.  Instead, Ballmer spoke about what he called the five “dimensions” of the cloud, and used that as the basis for an almost philosophical discussion.  Ballmer opined on how the cloud should be distinguished from the Internet.as well as what the cloud will and should enable.  Ballmer worked hard to portray the cloud not as a challenger to Windows and PCs (as Google would certainly suggest it is) but  really as just the latest peripheral that adds value to PCs and devices. At one point during his speech, Ballmer said “We start with Windows at Microsoft.  It’s the most popular smart device on the planet.  And our design center for the future of Windows is to make it one of those smarter devices that the cloud really wants.”  I’m not sure I agree with Ballmer’s ambition here, but I must admit he’s taken the “software + services” concept and expanded on it in more consumer-friendly fashion. There were demos too.  For example, Blaise Aguera y Arcas reprised his Bing Maps demo from the TED conference held last month.  And Simon Atwell showed how Microsoft has teamed with Sky TV in the UK to turn Xbox into something that looks uncannily like Windows Media Center.  Specifically, an Xbox console app called Sky Player provides full access to Sky’s on-demand programming but also live TV access to an array of networks carried on its home TV service, complete with an on-screen programming guide.  Windows Phone 7 Series was shown quickly and Ballmer told us that while Windows Mobile/Phone 6.5 and earlier were designed for voice and legacy functionality, Windows Phone 7 Series is designed for the cloud. Over and over during Ballmer’s talk (and those of his guest demo presenters), the message was clear: Microsoft believes that client (“smart”) devices, and not mere HTML terminals, are the technologies to best deliver on the promise of the cloud.  The message was that PCs running Windows, game consoles and smart phones  whose native interfaces are Internet-connected offer the most effective way to utilize cloud capabilities.  Even the Bing Maps demo conveyed this message, because the advanced technology shown in the demo uses Silverlight (and thus the PCs computing power), and not AJAX (which relies only upon the browser’s native scripting and rendering capabilities) to produce the impressive interface shown to the audience. Microsoft’s new slogan, with respect to the cloud, is “we’re all in.”  Just as a Texas Hold ‘em player bets his entire stash of chips when he goes all in, so too is Microsoft “betting the company” on the cloud.  But it would seem that Microsoft’s bet isn’t on the cloud in a pure sense, and is instead on the power of the cloud to fuel new growth in PCs and other client devices, Microsoft’s traditional comfort zone.  Is that a bet or a hedge?  If the latter, is Microsoft truly all in?  I don’t really know.  I think many people would say this is a sucker’s bet.  But others would say it’s suckers who bet against Microsoft.  No matter what, the burden is on Microsoft to prove this contrarian view of the cloud is a sensible one.  To do that, they’ll need to deliver on cloud-connected device innovation.  And to do that, the whole company will need to feel that victory is crucial.  Time will tell.  And I expect to present progress reports in future posts.

    Read the article

  • At the Java DEMOgrounds - Oracle Java ME Embedded Enables the “Internet of Things”

    - by Janice J. Heiss
    I caught up with Oracle’s Robert Barnes, Senior Director, Java Product Management, who was demonstrating a new product from Oracle’s Java Platform, Micro Edition (Java ME) product portfolio, Oracle Java ME Embedded 3.2, a complete client Java runtime optimized for microcontrollers and other resource-constrained devices. Oracle’s Java ME Embedded 3.2 is a Java ME runtime based on CLDC 1.1 (JSR-139) and IMP-NG (JSR-228).“What we are showing here is the Java ME Embedded 3.2 that we announced last week,” explained Barnes. “It’s the start of the 'Internet of Things,’ in which you have very very small devices that are on the edge of the network where the sensors sit. You often have a middle area called a gateway or a concentrator which is fairly middle to higher performance. On the back end you have a very high performance server. What this is showing is Java spanning all the way from the server side right down towards the type of chip that you will get at the sensor side as the network.” Barnes explained that he had two different demos running.The first, called the Solar Panel System Demo, measures the brightness of the light.  “This,” said Barnes, “is a light source demo with a Cortex M3 controlling the motor, on the end of which is a sensor which is measuring the brightness of the lamp. This is recording the data of the brightness of the lamp and as we move the lamp out of the way, we should be able using the server to turn the sensor towards the lamp so the brightness reading will go higher. This sends the message back to the server and we can look at the web server sitting on the PC underneath the desk. We can actually see the data being passed back effectively through a back office type of function within a utility environment.” The second demo, the Smart Grid Response Demo, Barnes explained, “has the same board and processor and is still using Java ME embedded with a different app on top. This is a demand response demo. What we are seeing within the managing environment is that people want to track the pricing signals of the electricity. If it’s particularly expensive at any point in time, they may turn something off. This demo sets the price of the electricity as though this is coming from the back of the server sending pricing signals to my home.” The demo had a lamp and a fan and it was tracking the price of electricity. “If I set the price of the electricity to go over 5 cents, then the device will turn off,” explained Barnes. “I can go into my settings and, in this case, change the price to 50 cents and we can wait a minus and the lamp will go off. When I change the pricing signal so that it is lower, the lamp will come back on. The key point is that the Java software we have running is the same across all the different devices; it’s a way to build applications across multiple devices using the same software. This is important because it fixes peak loading on the network and can stops blackouts.” This demo brought me back to a prior decade when Sun Microsystems first promoted  Jini technology, a version of Java that would put everything on the network and give us the smart home. Your home would be automated to tell you when you were out of milk, when to change your light bulbs, etc. You would have access to the web and the network throughout your home.It’s interesting to see how technology moves over time – from the smart home to the Internet of Things.

    Read the article

  • UPOS RFIDScanner data format

    - by Robert Snyder
    A lot of work that I do currently is based in the OPOS/UPOS world. My company has a device that can read 13.56Mhz tags (RFID), Smart Cards, and Mag Stripe cards. Up until somewhat recently I have only been working with RFID for a very specific scenario. That was to read UltraLight C and Desfire cards. These cards were all setup very specifically so that I could take the data read from those cards and force it into a MSR track2 format. The past couple of weeks, however, I have been working on reading RFID credit cards (since I have a Visa card I've been using mine), and Smart Card credit cards. (The visa card I have has both) In learning how to communicate with SmartCard and reading ISO7816 and EMVCO documents I became a little more familiar with how info is stored. But now I have a question regarding UPOS. The RFID data on my Visa is stored (and read) very similar to how the data is stored and read from the Smart Card on my Visa. Cool. Well in the UPOS spec for SmartCardRW the ReadData method returns a byte array. That's cool, I can just return all that data and then parse it as my heart desires. The RFID though has a LinkedList of Tags. Well this makes sense in terms of my Visa card (reminds me of a question I have in regards to SmartCard, but that is for another question) but what about ULC and Desfire, or for that matter any Mifare card. Pages, Files, Purses don't exactly fit the Tag profile. For instance lets just say I read pages 4-12 on my ULC card. Each page I read is 4 bytes long. Does this mean I have 9 tags in my LinkedList? Is my Tag id the page number? Or then how does that translate to Desfire? I open application 123456 and read file 1 and file 2, Do I have 2 tags? and if so what is my tag id? At least with my Visa I think that I have to use the Tag id (ex 5F24 for my expiration date) and value of {0x15, 0x10, 0x31} Part of me says yes..that makes sense. Another part of me says, "well if that is the case then why doesn't SmartCardRW have Tags?" So that is my question. How do I format my data from those different types of media? or is that the job of my Control Object (the application)? Is so how does it know? The only protocols I have are: // Summary: // Enumerates the available predefined RFID tag protocols the device supports. [Flags] public enum RFIDProtocols { EpcClass0 = 1, RFIDSdt0Plus = 2, EpcClass1 = 4, EpcClass1Gen2 = 8, EpcClass2 = 16, Iso14443A = 4096, Iso14443B = 8192, Iso15693 = 12288, Iso180006B = 16384, Other = 16777216, All = 1073741824, } If I use that well all of my cards that I have are all Iso14443A. I use the ATQA and the SAK to know what type of card I really have. There is no RFID property that lets me specify that. So I'm lost.

    Read the article

  • WebCenter Customer Spotlight: Hyundai Motor Company

    - by me
    Author: Peter Reiser - Social Business Evangelist, Oracle WebCenter  Solution SummaryHyundai Motor Company is one of the world’s fastest-growing car manufacturers, ranked as the fifth-largest in 2011. The company also operates the world’s largest integrated automobile manufacturing facility in Ulsan, Republic of Korea, which can produce 1.6 million units per year. They  undertook a project to improve business efficiency and reinforce data security by centralizing the company’s sales, financial, and car manufacturing documents into a single repository. Hyundai Motor Company chose Oracle Exalogic, Oracle Exadata, Oracle WebLogic Sever, and Oracle WebCenter Content 11g, as they provided better performance, stability, storage, and scalability than their competitors.  Hyundai Motor Company cut the overall time spent each day on document-related work by around 85%, saved more than US$1 million in paper and printing costs, laid the foundation for a smart work environment, and supported their future growth in the competitive car industry. Company OverviewHyundai Motor Company is one of the world’s fastest-growing car manufacturers, ranked as the fifth-largest in 2011. The company also operates the world’s largest integrated automobile manufacturing facility in Ulsan, Republic of Korea, which can produce 1.6 million units per year. The company strives to enhance its brand image and market recognition by continuously improving the quality and design of its cars. Business Challenges To maximize the company’s growth potential, Hyundai Motor Company undertook a project to improve business efficiency and reinforce data security by centralizing the company’s sales, financial, and car manufacturing documents into a single repository. Specifically, they wanted to: Introduce a smart work environment to improve staff productivity and efficiency, and take advantage of rapid company growth due to new, enhanced car designs Replace a legacy document system managed by individual staff to improve collaboration, the visibility of corporate documents, and sharing of work-related files between employees Improve the security and storage of documents containing corporate intellectual property, and prevent intellectual property loss when staff leaves the company Eliminate delays when downloading files from the central server to a PC Build a large, single document repository to more efficiently manage and share data between 30,000 staff at the company’s headquarters Establish a scalable system that can be extended to Hyundai offices around the world Solution DeployedAfter conducting a large-scale benchmark test, Hyundai Motor Company chose Oracle Exalogic, Oracle Exadata, Oracle WebLogic Sever, and Oracle WebCenter Content 11g, as they provided better performance, stability, storage, and scalability than their competitors. Business Results Lowered the overall time spent each day on all document-related work by approximately 85%—from 4.5 hours to around 42 minutes on an average day Saved more than US$1 million per year in printer, paper, and toner costs, and laid the foundation for a completely paperless environment Reduced staff’s time spent requesting and receiving documents about car sales or designs from supervisors by 50%, by storing and managing all documents across the corporation in a single repository Cut the time required to draft new-car manufacturing, sales, and design documents by 20%, by allowing employees to reference high-quality data, such as marketing strategy and product planning documents already in the system Enhanced staff productivity at company headquarters by 9% by reducing the document-related tasks of 30,000 administrative and research and development staff Ensured the system could scale to hold 3 petabytes of car sales, manufacturing, and design data by 2013 and be deployed at branches worldwide We chose Oracle Exalogic, Oracle Exadata, and Oracle WebCenter Content to support our new document-centralization system over their competitors as Oracle offers stable storage for petabytes of data and high processing speeds. We have cut the overall time spent each day on document-related work by around 85%, saved more than US$1 million in paper and printing costs, laid the foundation for a smart work environment, and supported our future growth in the competitive car industry. Kang Tae-jin, Manager, General Affairs Team, Hyundai Motor Company Additional Information Hyundai Motor Company Customer Snapshot Oracle WebCenter Content

    Read the article

  • X509 Certificates, DigitalSignature vs NonRepudiation (C#)

    - by Eyvind
    We have been handed a set of test sertificates on smart cards for developing a solution that requires XML messages to be signed using PKI. Each (physical) smart card seems to have two certificates stored on it. I import them into the Windows certificate store using software supplied by the smart card provider, and then use code resembling the following to iterate over the installed certificates: foreach (X509Certificate2 x509 in CertStore.Certificates) { foreach (X509Extension extension in x509.Extensions) { if (extension.Oid.Value == "one we are interested in") { X509KeyUsageExtension ext = (X509KeyUsageExtension)extension; if ((ext.KeyUsages & X509KeyUsageFlags.DigitalSignature) != X509KeyUsageFlags.None) { // process certs here We have been told to use the certificates that have the NonRepudiation key usage flag set to sign the XMLs. However, the certificate that has the NonRepudiation flag has this flag only, and not for instance the DigitalSignature flag which I check for above. Does this strike anyone but me as slightly odd? I am in other words told to sign with a certificate that does not (appear to) have the DigitalSignature usage flag set. Is this normal procedure? Any comments? Thanks.

    Read the article

  • useer degined Copy ctor, and copy-ctors further down the chain - compiler bug ? programers brainbug

    - by J.Colmsee
    Hi. i have a little problem, and I am not sure if it's a compiler bug, or stupidity on my side. I have this struct : struct BulletFXData { int time_next_fx_counter; int next_fx_steps; Particle particles[2];//this is the interesting one ParticleManager::ParticleId particle_id[2]; }; The member "Particle particles[2]" has a self-made kind of smart-ptr in it (resource-counted texture-class). this smart-pointer has a default constructor, that initializes to the ptr to 0 (but that is not important) I also have another struct, containing the BulletFXData struct : struct BulletFX { BulletFXData data; BulletFXRenderFunPtr render_fun_ptr; BulletFXUpdateFunPtr update_fun_ptr; BulletFXExplosionFunPtr explode_fun_ptr; BulletFXLifetimeOverFunPtr lifetime_over_fun_ptr; BulletFX( BulletFXData data, BulletFXRenderFunPtr render_fun_ptr, BulletFXUpdateFunPtr update_fun_ptr, BulletFXExplosionFunPtr explode_fun_ptr, BulletFXLifetimeOverFunPtr lifetime_over_fun_ptr) :data(data), render_fun_ptr(render_fun_ptr), update_fun_ptr(update_fun_ptr), explode_fun_ptr(explode_fun_ptr), lifetime_over_fun_ptr(lifetime_over_fun_ptr) { } /* //USER DEFINED copy-ctor. if it's defined things go crazy BulletFX(const BulletFX& rhs) :data(data),//this line of code seems to do a plain memory-copy without calling the right ctors render_fun_ptr(render_fun_ptr), update_fun_ptr(update_fun_ptr), explode_fun_ptr(explode_fun_ptr), lifetime_over_fun_ptr(lifetime_over_fun_ptr) { } */ }; If i use the user-defined copy-ctor my smart-pointer class goes crazy, and it seems that calling the CopyCtor / assignment operator aren't called as they should. So - does this all make sense ? it seems as if my own copy-ctor of struct BulletFX should do exactly what the compiler-generated would, but it seems to forget to call the right constructors down the chain. compiler bug ? me being stupid ? Sorry about the big code, some small example could have illustrated too. but often you guys ask for the real code, so well - here it is :D

    Read the article

  • Recommendation for PHP-FPM pm.max_children, PHP-FPM pm.start_servers and others

    - by jaypabs
    I have the following server: Intel® Xeon® E3-1270 v2 Single Processor - Quad Core Dedicated Server CPU Speed: 4 x 3.5 Ghz w/ 8MB Smart Cache Motherboard: SuperMicro X9SCM-F Total Cores: 4 Cores + 8 Threads RAM: 32 GB DDR3 1333 ECC Hard Drive: 120GB Smart Cache: 8MB I am using ubuntu 12.04 - nginx, php, mysql with ISPConfig 3. Under ISPConfig 3 website settings: I have this default value: PHP-FPM pm.max_children = 10 PHP-FPM pm.start_servers = 2 PHP-FPM pm.min_spare_servers = 1 PHP-FPM pm.max_spare_servers = 5 PHP-FPM pm.max_requests = 0 My question is what is the recommended settings for the above variable? Because I found some using a different settings.

    Read the article

  • Two SATA HDDs connected using a Black Duet HDD Docking Station via eSATA to my Laptop, second drive

    - by leeand00
    Hi I am using a BlacX Duet HDD Docking Station to connect a 1TB WD Caviar Black SATA HDD (WD10000LSRTL) and a HITACHI SATA DESKSTAR (0S00163) to my G51VX (BestBuy) laptop via the eSATA port. When I plug in both HDDs in to the Docking Station, connect the docking station to my laptop and start Windows 7 (64-bit Ultimate), only the HDD in the first drive in the port actually shows up in My Computer and Disk Management. If I swap the drives positions I can get them both to work, but never at the same time. I also checked in the bios settings on the laptop, under Advanced-IDE Configuration-SATA Operation Mode, and it displays: SATA Operation Mode: [Enhanced] AHCI Port0 [Hard Disk] Device: Hard Disk Vendor: ST9320421AS LBA Mode: Supported S.M.A.R.T.: Supported AHCI Port5 [Hard Disk] Device: Hard Disk Vendor: Hitachi HDS721010CLA332 Size: 100.00 GB LBA Mode: Supported S.M.A.R.T.: Supported There should be a third drive, but I'm not certain why it is not being picked up. Additionally, before I played around with the settings in the IDE configuration, it used to display the DVD as well.

    Read the article

  • OCZ Vertex 2 not recognized by Ubuntu installer

    - by Zsub
    As I boot into the Ubuntu 10.10 (or 11.04, doesn't matter) live environment or installer, it just refuses to recognise my Vertex 2. It reports the disk as ATA and not supporting smart, shows no serial number, and doesn't list the size correctly. All fdisk tells me is Unable to read /dev/sda (it's the only storage in the PC). I'm now running a temporary install of Windows 7 off of it, which worked like a charm, so where am I going wrong with Ubuntu... Specs: Asus M4N68T-M LE V2 (BIOS 0702, most recent) OCZ Vertex 2 SSD 60 GB Amd Athlon II X4 640 Patriot PSD34G13332 4GB DDR3 ram (two banks) EDIT I installed a second drive, installed Ubuntu on that and booted, it recognised the SSD just fine. I'm now trying to apt-get upgrade the live-environment. I wonder if there is any way to sort of install Ubuntu from Ubuntu (I boot into the working install on the other drive, install it on the SSD and then boot from the SSD). EDIT2 Ok, so that doesn't work. The install detects the SSD, however, it cannot format it. EDIT3 After a fresh boot I can read out SMART-data and even perform a read-benchmark, but if I try to format it, or do a write-bench, it'll crap out and after that it says SMART is not supported. So basically it seems I can't write to the disk, as it will stop working when I do, I will try to run repeated read-benchmarks to see if that has any effect. EDIT4 I'm running several read benchmarks on the drive right now, they give results that are to be expected from an SSD. If the read-benches don't fail, I can use fdisk on the disk, but it is now stuck trying to re-read the partition table after issueing the 'w' command. EDIT5 Parted Magic did recognize the drive and with hdparm -I even could tell me the drive was in a frozen state. I powercycled it (just pull out the plug from the SSD and plug it back in) and it wasn't frozen anymore. After that I could upgrade the firmware on the drive (still using Parted Magic) and format it to Ext4. After I rebooted into the Ubuntu installer, it wouldn't get recognized and hdparm didn't want to talk to it saying HDIO_DRIVE_CMD(identify) failed: Invalid exchange. EDIT6 For some reason if I enable one of the RAID controllers (the one the SSD is connected to, obviously) Ubuntu will let me format it, mount it and write to it. The installer also recognizes it. However if the raid controller is enabled but no array is defined the motherboard can't boot from it :(

    Read the article

  • Adaptec 5805 after reboot don't starting

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not included. It only works if the computer is shut down and turn off. Late i update firmware "Adaptec RAID 5805 Firmware Build 18948" How to fix the problem? add Log Configuration summary Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priorityHigh Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1 List item

    Read the article

  • One server, Two APC UPS on redundant power supplies : How to trigger shutdown ?

    - by Falken
    I have a server racked and its redundant power supplies plugged in two APC Smart-UPS 3000 XLM. Each UPS is connected to two different mains power sources. Two instances of apcupsd are running, each one connected to its own UPS. They can both detect when an UPS is on Battery, and each UPS can then trigger a shutdown on the server. Question is : How NOT to shutdown if ONLY ONE UPS runs out of battery ? Note : Smart-UPS 3000 XLM has a "Power Sync" Function that is able to connect to its peer and detect its status. But when I pulled the plug out of one of them, the Shutdown order was sent anyway. I'm thinking about modifying the shutdown scripts to check with "apcaccess" if the other ups is down. Any experience on this would be appreciated !

    Read the article

  • When running a shell script, how can you protect it from overwriting or truncating files?

    - by Joseph Garvin
    If while an application is running one of the shared libraries it uses is written to or truncated, then the application will crash. Moving the file or removing it wholesale with 'rm' will not cause a crash, because the OS (Solaris in this case but I assume this is true on Linux and other *nix as well) is smart enough to not delete the inode associated with the file while any process has it open. I have a shell script that performs installation of shared libraries. Sometimes, it may be used to reinstall versions of shared libraries that were already installed, without an uninstall first. Because applications may be using the already installed shared libraries, it's important the the script is smart enough to rm the files or move them out of the way (e.g. to a 'deleted' folder that cron could empty at a time when we know no applications will be running) before installing the new ones so that they're not overwritten or truncated. Unfortunately, recently an application crashed just after an install. Coincidence? It's difficult to tell. The real solution here is to switch over to a more robust installation method than an old gigantic shell script, but it'd be nice to have some extra protection until the switch is made. Is there any way to wrap a shell script to protect it from overwriting or truncating files (and ideally failing loudly), but still allowing them to be moved or rm'd? Standard UNIX file permissions won't do the trick because you can't distinguish moving/removing from overwriting/truncating. Aliases could work but I'm not sure what entirety of commands need to be aliased. I imagine something like truss/strace except before each action it checks against a filter whether to actually do it. I don't need a perfect solution that would work even against an intentionally malicious script. Ideas I have so far: Alias cp to GNU cp (not the default since I'm on Solaris) and use the --remove-destination option. Alias install to GNU install and use the --backup option. It might be smart enough to move the existing file to the backup file name rather than making a copy, thus preserving the inode. "set noclobber" in ~/.bashrc so that I/O redirection won't overwrite files

    Read the article

  • Suppress log messages about 3ware disk temperature changes on CentOS?

    - by Stefan Lasiewski
    I have a number of CentOS 5 servers which use 3ware RAID controllers. These servers are bugging my team with messages about minor temperature changes, like this: Jun 8 12:32:39 HOST smartd[1231]: Device: /dev/twa0 [3ware_disk_01], SMART Usage Attribute: 194 Temperature_Celsius changed from 119 to 118 Jun 8 12:32:39 HOST smartd[1231]: Device: /dev/twa0 [3ware_disk_03], SMART Usage Attribute: 194 Temperature_Celsius changed from 122 to 121 How can I suppress these messages? According to man smartd.conf : To disable any of the 3 reports, set the corresponding limit to 0. Trailing zero arguments may be omitted. By default, all temperature reports are disabled (´-W 0´). On my systems, smartd is reporting about temperature changes by default. I tried a manual approach. In /etc/smartd.conf, I have the following: /dev/twa0 -d 3ware,1 -a -W 0 /dev/twa0 -d 3ware,3 -a -W 0 But this still does not suppress the messages. Since these messages show up in /var/log/messages, LogWatch is sending unnecessary emails every night.

    Read the article

  • Battery backed write cache behavior upon disk change

    - by Halfgaar
    We use 3ware Inc 9650SE SATA-II RAID PCIe RAID controllers with battery backed write cache. Our spare hardware has the same controller. I was wondering; are these controllers smart enough not to sync the cache when the disks have been changed? For example, if I deploy one of those spare machines by putting in the disks of another machine and that spare machine still has pending writes, will it be smart enough not to perform those writes on the replaced array? Edit: my scenario is not really made clear, so let me give an example: server1 goes down because of power supply failure. I put the disks in server2 and start. I repair server1 I put the disks back from server2 in server1 (it's not relevant right now that in reality I would probably keep server2 running). If server1 doesn't have safeguards, it will write to the array, thinking it's simply powering up again, corrupting it.

    Read the article

  • Sporadic disk clicking sound

    - by Abdó
    Hi, I'm having some unusual and sporadic hard disk clicking issues. Here is a cronological description of the facts. I'm using an ASUS P6T-SE with Intel Core i7, 6Gb RAM 600W Power supply and ATI4670 graphics, running Ubuntu 10.10. About one month ago my hard disk (SATA II Seagate Barracuda 1Tb 7200 rpm) started making a clicking sound: a sort of loud tic-tac, every second or so, when involved in disk activity. The system was clearly slower than before at disk access, but it was functional and I could not find any signal of trouble on the linux logs. I disconnected the disk and tried an older SATA drive I had around: no problem with it. Then I reconnected the Seagate disk, and the problem was mysteriously gone. Ubuntu booted normally, usual speed, no clicking. A couple of weeks later, the problem reappeared. I tried disconnecting reconnecting (as it somehow solved the problem before) without luck. So, despite it was a rather new drive, I assumed it was a hardware issue, made backups and bought a new drive. The new drive is a SATA II Seagate Barracuda 1.5 Tb 7200 rpm. I installed both drives at the same time, with the intention of transferring my files from on to the other. To my surprise, when I booted the computer with both drives, both started making the clicking sound !! Even worse, I removed the old drive, leaving the unformated new drive connected, and booted from a LiveCD. It kept clicking ! Puzzled by this, I tried both drives on my laptop with a SATA to USB cable. At the moment I connected any of them, they made one or two unusual clicks and immediately stopped doing that and worked normally. The old drive I thought almost dead, was working like a charm as if nothing happened. Then I thought: "ok, it must be the motherboard. Let's try again". So, I reconnected the old drive to the ASUS P6T motherboard (the same cables and SATA port as before), and it worked as if nothing happened ! The problem was gone again. The new 1.5 Tb drive was also working ok: No clicking nor slowdown. So I left the old 1Tb disk connected and kept using the computer daily during 3 weeks, until today it happened again. Now I don't really know what to do or check. I'm not even sure if it is a hardware issue any more ! This is rather annoying as it seems it happens with a period of 2 or 3 weeks and I have no means of forcing it to happen. Does anyone have a clue of what can causes this behaviour or have any suggestions of things I should check when it happens again ? What I did today is checking some SMART parameters Error log: smartctl -l error /dev/sda. No errors Short selftest: smartctl -t short /dev/sda. No errors Disk Health check: smartctl -H /dev/sda. passed And here are the vendor specific parameters (smartctl -A /dev/sda) Which I'm not quite sure how to interpret. === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 120 099 006 Pre-fail Always - 235962588 3 Spin_Up_Time 0x0003 095 095 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 187 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 072 060 030 Pre-fail Always - 16348045 9 Power_On_Hours 0x0032 096 096 000 Old_age Always - 3590 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 94 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 097 000 Old_age Always - 4295164029 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 070 057 045 Old_age Always - 30 (Lifetime Min/Max 19/31) 194 Temperature_Celsius 0x0022 030 043 000 Old_age Always - 30 (0 18 0 0) 195 Hardware_ECC_Recovered 0x001a 037 026 000 Old_age Always - 235962588 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 73950746906346 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 1832967731 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 3294986902 Any clue to this mystery will be really welcome. Thank you very much !!

    Read the article

  • Adaptec 5805 not recognized after reboot

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not recognized. It only works if the computer is shut down and turned off. I have recently updated the firmware to "Adaptec RAID 5805 Firmware Build 18948". How do I fix the problem? Configuration summary --------------------------- 1. Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priority High Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1

    Read the article

  • HDD bad sectors with OS

    - by Michael Z
    I wonder is that possible for OS to make bad sectors on Hard Drive? Preface: I have bought new HDD on 1Tb WB Caviar Black. I have installed new OS on ext4 partition Ubuntu 12.04.1 LTS. After few days S.M.A.R.T. of the Ubuntu's Disk Utility show that my hard has bad sectors! I have checked on S.M.A.R.T. immediately after installing OS - all was OK. During new OS working I have noticed some strange with HDD - all OS was freezed from 20 sec to 1 min and I have heard like HDD's engine restarting. At the dmes I have found something like this: [40085.407947] ata1.00: device reported invalid CHS sector 0

    Read the article

  • Sync Banshee library data.

    - by Dom
    I use Banshee to organise my music, I particularly like its scoring system and I have smart playlists based on it. However, I have two versions of my music library, one on each of my computers. As one of the computers is small I only have a favourite set of songs on that computer rather than my whole collection. The computers are not on a local network, but I do use Ubuntu One for file sharing between them. Is there any way I can synchronise song data (play count, score, skip count ...) and playlist data (including smart playlists that include songs based on this data) between the two computers? This would only be relevant of course for the songs that exist on both computers, the songs that exist on only one would need to be ignored. I did consider putting the library data file (I think it is .xml but I'm not sure) into the shared file and creating a symbolic link to it, but then I wouldn't be able to have a different set of songs on each computer. Thank you.

    Read the article

  • Recover strategy single bad sector in moricon

    - by Damon
    This week, my harddisk made me an early christmas present in the form of a single defect sector. To make up for the puny size of the present, it chose a sector inside moricons.dll for that. This means that now the system takes about 5 minutes to boot before Windows gives up and moves on, and there's 2 dozen scary "critical failure" entries in the system log after every boot, which is annoying. OK, admittedly, I shouldn't complain, it could be worse, the bad sector could be in ntldr... SMART info more or less indicates (for what SMART can indicate anyway) that the drive is mostly OK. Soft Read Error Rate has a score of 96, and Current Pending Sector Count has a raw value of 8, which translates to a score of 100. Acronis DriveMonitor makes this an issue (lowering the overall rating to 75%), HDD Health calls it "excellent", giving an overall rating of 95% (which is what this harddisk from day one). No single score is below 95 (power on hours and spin up count), and most are 100 anyway. Well, whatever, I've seen drives with perfect SMART values fail from one second to the other, and drives with moderate values work for years. So, I'm inclined not to put too much weight into that overall. TL;DR Now... to the problem: I don't feel like trashing the disk just yet (that's planned with a new OS install upgrading to Win7 early next year, independently of this issue), but in the mean time, I would still like to have a smoothly running system again. Therefore, I feel tempted to tamper with it, but before I render my system entirely unusable (since I've never done this before), I'd like to verify that my planned procedere is likely to suceed in having a working system again: Copy moricons.dl_ from the Windows install disk, rename it to moricons.zip, and unzip it. This gives an intact 5.1.2600.2180 version (the broken one is 5.1.2600.5512 - but I guess this makes not much of a difference, since it's an icon-only DLL, and an outdated copy should work better than one that can't be read) Run chkdsk /r /f` which will "repair" the file (i.e. delete the file without asking, tell the drive to remap the sector, and toss some unreadable junk into a file with a hexadecimal number) Hopefully Windows still boots after this (is that a reasonable expectation, or do I need to have something like BartPE ready? -- but then again, what's that good for in case chkdsk has nuked the entire file system...) Delete the junk file generated by chkdsk, copy the new DLL to %windir%\system32 Reboot. Pray. Maybe I just shouldn't touch anything, since it still kind of works... if annoying, but it works. Unsure... But, is there anything fundamentally wrong with the planned approach? Is this a sensible approach at all?

    Read the article

  • Multiple WAPs: Bandwidth, Frequency Considerations

    - by Pete Cresswell
    The router in my LAN closet does 2 and 5 GHz. In the kitchen, I have a single-band 2 GHz WAP, and in the garden shed I have another single-band 2 GHz WAP. All are set to Bandwidth = 40 MHz, Wireless Network Mode = N-Only. The kitchen WAP and the LAN closet router both come up with multiple bars on my smart phone from almost anywhere in the house. The garden shed WAP will register one bar... but only sometimes. The Questions: Are these things in danger of butting heads? Should I re-set them to Bandwidth = 20 MHz? Bandwidth = Auto? Are there any tools that I could use on an Android smart phone, iPod, or WiFi-enabled laptop to make my own analysis?

    Read the article

< Previous Page | 18 19 20 21 22 23 24 25 26 27 28 29  | Next Page >