Search Results

Search found 19658 results on 787 pages for 'multiple nics'.

Page 228/787 | < Previous Page | 224 225 226 227 228 229 230 231 232 233 234 235  | Next Page >

  • Possible / How to render to multiple back buffers, using one as a shader resource when rendering to the other, and vice versa?

    - by Raptormeat
    I'm making a game in Direct3D10. For several of my rendering passes, I need to change the behavior of the pass depending on what is already rendered on the back buffer. (For example, I'd like to do some custom blending- when the destination color is dark, do one thing; when it is light, do another). It looks like I'll need to create multiple render targets and render back and forth between them. What's the best way to do this? Create my own render textures, use them, and then copy the final result into the back buffer. Create multiple back buffers, render between them, and then present the last one that was rendered to. Create one render texture, and one back buffer, render between them, and just ensure that the back buffer is the final target rendered to I'm not sure which of these is possible, and if there are any performance issues that aren't obvious. Clearly my preference would be to have 2 rather than 3 default render targets, if possible.

    Read the article

  • If you should only have one assertion per test; how to test multiple inputs?

    - by speg
    I'm trying to build up some test cases, and have read that you should try and limit the number of assertions per test case. So my question is, what is the best way to go about testing a function w/ multiple inputs. For example, I have a function that parses a string from the user and returns the number of minutes. The string can be in the form "5w6h2d1m", where w, h, d, m correspond to the number of weeks, hours, days, and minutes. If I wanted to follow the '1 assertion per test rule' I'd have to make multiple tests for each variation of input? That seems silly so instead I just have something like: self.assertEqual(parse_date('5m'), 5) self.assertEqual(parse_date('5h'), 300) self.assertEqual(parse_date('5d') ,7200) self.assertEqual(parse_date('1d4h20m'), 1700) In the one test case. Is there a better way?

    Read the article

  • What would be topic for research in on edge of multiple processors / computers programming?

    - by Kabumbus
    I mean what is not already there? What can be developed in fiew month and give a breakthrue/ start a new leap in science of f multiple computers programming? What i see is already there MPI/ Bit torrent/Jabber protocols / APIs / servers for messaging LAN / wire and other infrastractural cabels for connecting Boost and analogs on evry OS in most languages for multithreading there are lots of CUDA like on computer frameworks for fast calculating on computers GPUs What I personally do not see out there is a crossplatform framework for multiple processes interaction. Meaning one that would allow easy creation of multyple processes running in paralell inside one hoster app on one machine. In level not harder than needed for threads creation (so no seprate server apps - just one lib doing it all) Is there ny such lib and what can you propose for research topic?

    Read the article

  • Why is it good to split a program into multiple classes?

    - by user1276078
    I'm still a student in high school (entering 10th grade), and I have yet to take an actual computer course in school. Everything I've done so far is through books. Those books have taught me concepts such as inheritance, but how does splitting a program into multiple classes help? The books never told me. I'm asking this mainly because of a recent project. It's an arcade video game, sort of like a flash game as some people have said (although I have no idea what a flash game is). The thing is, it's only one class. It works perfectly fine (a little occasional lag however) with just one class. So, I'm just asking how splitting it into multiple classes would help it. This project was in JAVA and I am the only person working on it, for the record.

    Read the article

  • Does facebook store multiple password hashes for each user?

    - by loxxy
    I noticed that Facebook allows multiple variants of my own password : My password as it is. My password with first letter capitalized. My password with all letters capitalized. It is commonly known that passwords are stored as hashes. So my question is, does facebook store multiple hashes for each user? Since the hash of each variant should be completely different... Or am I missing something, here? And there may be more combinations, besides the one I observed as well. This is obviously done to provide a better user experience & they probably have a statistical explanation of people repeating these mistakes. But I could not help but wonder, is it worth to increase so many lookups (in their database) just to help the user type a wrong password? On top of this, they warn about the caps lock (even though they don't seem to care) :

    Read the article

  • How can you deploy with juju multiple times the same application within the same environment? [closed]

    - by Pere Hospital
    Possible Duplicate: How do I deploy multiple stacks in an environment? If trying to deploy two times wordpress i.e. in the same environment you get: 2012-12-19 16:56:54,588 INFO Searching for charm cs:precise/wordpress in charm store 2012-12-19 16:56:55,472 INFO Connecting to environment... 2012-12-19 16:57:01,044 INFO Connected to environment. 2012-12-19 16:57:01,374 INFO Using cached charm version of wordpress 2012-12-19 16:57:01,857 ERROR Service name 'wordpress' is already in use This would apply for a situation where you want to deploy multiple wordpress blogs using the same env (i.e. same amazon account).

    Read the article

  • How to configure multiple iSCSI Portal Groups on a EqualLogic PS6100?

    - by kce
    I am working on a migration from a VMware vSphere environment to a Hyper-V Cluster utilizing Windows Server 2012 R2. The setup is pretty small, an EqualLogic PS6100e and two Dell PowerConnect 5424 switches and handful of R710s and R620s. The SAN was configured as a non-RFC1918 network that is not assigned to our organization and since I am working on building a new virtualization environment I figured that this would be an appropriate time to do a subnet migration. I configured a separate VLAN and subnet on the switches and the two previously unused NICs on the PS6100's controllers. At this time I only have a single Hyper-V host cabled in but I can successfully ping the PS6100 from the host. From the PS6100 I can ping each of the four NICs that currently on the storage network. I cannot connect the Microsoft iSCSI Initiator to the Target. I have successfully added the Target Portals (the IP addresses of PS6100 NICs) and the Targets are discovered but listed as inactive. If I try to Connect to them I get the following error, "Log onto Target - Connection Failed" and ISCSIPrt 1 and 70 events are recorded in the Event Log. I have verified that access control to the volume is not the problem by temporarily disabling it. I suspect the problem is with the Portal Group IP address which is still listed as Group Address of old subnet (I know, I know I might be committing the sin of the X/Y problem but everything else looks good): RFC3720 has this to say about Network Portal and Portal Groups: Network Portal: The Network Portal is a component of a Network Entity that has a TCP/IP network address and that may be used by an iSCSI Node within that Network Entity for the connection(s) within one of its iSCSI sessions. A Network Portal in an initiator is identified by its IP address. A Network Portal in a target is identified by its IP address and its listening TCP port. Portal Groups: iSCSI supports multiple connections within the same session; some implementations will have the ability to combine connections in a session across multiple Network Portals. A Portal Group defines a set of Network Portals within an iSCSI Network Entity that collectively supports the capability of coordinating a session with connections spanning these portals. Not all Network Portals within a Portal Group need participate in every session connected through that Portal Group. One or more Portal Groups may provide access to an iSCSI Node. Each Network Portal, as utilized by a given iSCSI Node, belongs to exactly one portal group within that node. The EqualLogic Group Manager documentation has this to say about the Group IP Address: You use the group IP address as the iSCSI discovery address when connecting initiators to iSCSI targets in the group. If you modify the group IP address, you might need to change your initiator configuration to use the new discovery address Changing the group IP address disconnects any iSCSI connections to the group and any administrators logged in to the group through the group IP address. Which sounds equivalent to me (I am following up with support to confirm). I think a reasonable explanation at this point is that the Initiator can't complete the connection to the Target because the Group IP Address / Network Portal is on a different subnet. I really want to avoid a cutover and would prefer to run both subnets side-by-side until I can install and configure each Hyper-V host. Question/s: Is my assessment at all reasonable? Is it possible to configure multiple Group IP Addresses on the EqualLogic PS6100? I don't want to just change it as it will disconnect the remaining ESXi hosts. Am I just Doing It Wrong(TM)?

    Read the article

  • Multiple Broadcast Messages with Less Data or Less Broadcast Messages with More Data?

    - by niko
    Hi, I am developing an application which is communicating with the server. Tha application can perform log-in and get different parameters from server. The application consists of a RESTful client (custom class for making requests), Communication Service (the service which runs in the background) and the main activity. For now I created multiple broadcast messages and multiple broadcast receivers in the main activity so when the application performs login operation a receiver (loginBroadcastReceiver) in the main activity receives a message and when another parameter is received from the server different message is broadcasted and another receiver handles the message. This way however the application performance is poor but I am not sure whether it is due to multiple broadcast receivers. Does anyone know what is the best way to exchange data between service and main activity - is it better to create a single broadcast receiver and retrieve all parameters from message or is it better to initialize multiple broadcast receivers for multiple parameters? I would appreciate if you could provide any useful resource about the topic because I'm writing the thesis and it would be good if the solution could be explained.

    Read the article

  • Why Is Vertical Resolution Monitor Resolution so Often a Multiple of 360?

    - by Jason Fitzpatrick
    Stare at a list of monitor resolutions long enough and you might notice a pattern: many of the vertical resolutions, especially those of gaming or multimedia displays, are multiples of 360 (720, 1080, 1440, etc.) But why exactly is this the case? Is it arbitrary or is there something more at work? Today’s Question & Answer session comes to us courtesy of SuperUser—a subdivision of Stack Exchange, a community-driven grouping of Q&A web sites. The Question SuperUser reader Trojandestroy recently noticed something about his display interface and needs answers: YouTube recently added 1440p functionality, and for the first time I realized that all (most?) vertical resolutions are multiples of 360. Is this just because the smallest common resolution is 480×360, and it’s convenient to use multiples? (Not doubting that multiples are convenient.) And/or was that the first viewable/conveniently sized resolution, so hardware (TVs, monitors, etc) grew with 360 in mind? Taking it further, why not have a square resolution? Or something else unusual? (Assuming it’s usual enough that it’s viewable). Is it merely a pleasing-the-eye situation? So why have the display be a multiple of 360? The Answer SuperUser contributor User26129 offers us not just an answer as to why the numerical pattern exists but a history of screen design in the process: Alright, there are a couple of questions and a lot of factors here. Resolutions are a really interesting field of psychooptics meeting marketing. First of all, why are the vertical resolutions on youtube multiples of 360. This is of course just arbitrary, there is no real reason this is the case. The reason is that resolution here is not the limiting factor for Youtube videos – bandwidth is. Youtube has to re-encode every video that is uploaded a couple of times, and tries to use as little re-encoding formats/bitrates/resolutions as possible to cover all the different use cases. For low-res mobile devices they have 360×240, for higher res mobile there’s 480p, and for the computer crowd there is 360p for 2xISDN/multiuser landlines, 720p for DSL and 1080p for higher speed internet. For a while there were some other codecs than h.264, but these are slowly being phased out with h.264 having essentially ‘won’ the format war and all computers being outfitted with hardware codecs for this. Now, there is some interesting psychooptics going on as well. As I said: resolution isn’t everything. 720p with really strong compression can and will look worse than 240p at a very high bitrate. But on the other side of the spectrum: throwing more bits at a certain resolution doesn’t magically make it better beyond some point. There is an optimum here, which of course depends on both resolution and codec. In general: the optimal bitrate is actually proportional to the resolution. So the next question is: what kind of resolution steps make sense? Apparently, people need about a 2x increase in resolution to really see (and prefer) a marked difference. Anything less than that and many people will simply not bother with the higher bitrates, they’d rather use their bandwidth for other stuff. This has been researched quite a long time ago and is the big reason why we went from 720×576 (415kpix) to 1280×720 (922kpix), and then again from 1280×720 to 1920×1080 (2MP). Stuff in between is not a viable optimization target. And again, 1440P is about 3.7MP, another ~2x increase over HD. You will see a difference there. 4K is the next step after that. Next up is that magical number of 360 vertical pixels. Actually, the magic number is 120 or 128. All resolutions are some kind of multiple of 120 pixels nowadays, back in the day they used to be multiples of 128. This is something that just grew out of LCD panel industry. LCD panels use what are called line drivers, little chips that sit on the sides of your LCD screen that control how bright each subpixel is. Because historically, for reasons I don’t really know for sure, probably memory constraints, these multiple-of-128 or multiple-of-120 resolutions already existed, the industry standard line drivers became drivers with 360 line outputs (1 per subpixel). If you would tear down your 1920×1080 screen, I would be putting money on there being 16 line drivers on the top/bottom and 9 on one of the sides. Oh hey, that’s 16:9. Guess how obvious that resolution choice was back when 16:9 was ‘invented’. Then there’s the issue of aspect ratio. This is really a completely different field of psychology, but it boils down to: historically, people have believed and measured that we have a sort of wide-screen view of the world. Naturally, people believed that the most natural representation of data on a screen would be in a wide-screen view, and this is where the great anamorphic revolution of the ’60s came from when films were shot in ever wider aspect ratios. Since then, this kind of knowledge has been refined and mostly debunked. Yes, we do have a wide-angle view, but the area where we can actually see sharply – the center of our vision – is fairly round. Slightly elliptical and squashed, but not really more than about 4:3 or 3:2. So for detailed viewing, for instance for reading text on a screen, you can utilize most of your detail vision by employing an almost-square screen, a bit like the screens up to the mid-2000s. However, again this is not how marketing took it. Computers in ye olden days were used mostly for productivity and detailed work, but as they commoditized and as the computer as media consumption device evolved, people didn’t necessarily use their computer for work most of the time. They used it to watch media content: movies, television series and photos. And for that kind of viewing, you get the most ‘immersion factor’ if the screen fills as much of your vision (including your peripheral vision) as possible. Which means widescreen. But there’s more marketing still. When detail work was still an important factor, people cared about resolution. As many pixels as possible on the screen. SGI was selling almost-4K CRTs! The most optimal way to get the maximum amount of pixels out of a glass substrate is to cut it as square as possible. 1:1 or 4:3 screens have the most pixels per diagonal inch. But with displays becoming more consumery, inch-size became more important, not amount of pixels. And this is a completely different optimization target. To get the most diagonal inches out of a substrate, you want to make the screen as wide as possible. First we got 16:10, then 16:9 and there have been moderately successful panel manufacturers making 22:9 and 2:1 screens (like Philips). Even though pixel density and absolute resolution went down for a couple of years, inch-sizes went up and that’s what sold. Why buy a 19″ 1280×1024 when you can buy a 21″ 1366×768? Eh… I think that about covers all the major aspects here. There’s more of course; bandwidth limits of HDMI, DVI, DP and of course VGA played a role, and if you go back to the pre-2000s, graphics memory, in-computer bandwdith and simply the limits of commercially available RAMDACs played an important role. But for today’s considerations, this is about all you need to know. Have something to add to the explanation? Sound off in the the comments. Want to read more answers from other tech-savvy Stack Exchange users? Check out the full discussion thread here.     

    Read the article

  • How can I render multiple windows with DirectX 9 in C++?

    - by Friso1990
    I'm trying to render multiple windows, using DirectX 9 and swap chains, but even though I create 2 windows, I only see the first one that I've created. My RendererDX9 header is this: #include <d3d9.h> #include <Windows.h> #include <vector> #include "RAT_Renderer.h" namespace RAT_ENGINE { class RAT_RendererDX9 : public RAT_Renderer { public: RAT_RendererDX9(); ~RAT_RendererDX9(); void Init(RAT_WindowManager* argWMan); void CleanUp(); void ShowWin(); private: LPDIRECT3D9 renderInterface; // Used to create the D3DDevice LPDIRECT3DDEVICE9 renderDevice; // Our rendering device LPDIRECT3DSWAPCHAIN9* swapChain; // Swapchain to make multi-window rendering possible WNDCLASSEX wc; std::vector<HWND> hwindows; void Render(int argI); }; } And my .cpp file is this: #include "RAT_RendererDX9.h" static LRESULT CALLBACK MsgProc( HWND hWnd, UINT msg, WPARAM wParam, LPARAM lParam ); namespace RAT_ENGINE { RAT_RendererDX9::RAT_RendererDX9() : renderInterface(NULL), renderDevice(NULL) { } RAT_RendererDX9::~RAT_RendererDX9() { } void RAT_RendererDX9::Init(RAT_WindowManager* argWMan) { wMan = argWMan; // Register the window class WNDCLASSEX windowClass = { sizeof( WNDCLASSEX ), CS_CLASSDC, MsgProc, 0, 0, GetModuleHandle( NULL ), NULL, NULL, NULL, NULL, "foo", NULL }; wc = windowClass; RegisterClassEx( &wc ); for (int i = 0; i< wMan->getWindows().size(); ++i) { HWND hWnd = CreateWindow( "foo", argWMan->getWindow(i)->getName().c_str(), WS_OVERLAPPEDWINDOW, argWMan->getWindow(i)->getX(), argWMan->getWindow(i)->getY(), argWMan->getWindow(i)->getWidth(), argWMan->getWindow(i)->getHeight(), NULL, NULL, wc.hInstance, NULL ); hwindows.push_back(hWnd); } // Create the D3D object, which is needed to create the D3DDevice. renderInterface = (LPDIRECT3D9)Direct3DCreate9( D3D_SDK_VERSION ); // Set up the structure used to create the D3DDevice. Most parameters are // zeroed out. We set Windowed to TRUE, since we want to do D3D in a // window, and then set the SwapEffect to "discard", which is the most // efficient method of presenting the back buffer to the display. And // we request a back buffer format that matches the current desktop display // format. D3DPRESENT_PARAMETERS deviceConfig; ZeroMemory( &deviceConfig, sizeof( deviceConfig ) ); deviceConfig.Windowed = TRUE; deviceConfig.SwapEffect = D3DSWAPEFFECT_DISCARD; deviceConfig.BackBufferFormat = D3DFMT_UNKNOWN; deviceConfig.BackBufferHeight = 1024; deviceConfig.BackBufferWidth = 768; deviceConfig.EnableAutoDepthStencil = TRUE; deviceConfig.AutoDepthStencilFormat = D3DFMT_D16; // Create the Direct3D device. Here we are using the default adapter (most // systems only have one, unless they have multiple graphics hardware cards // installed) and requesting the HAL (which is saying we want the hardware // device rather than a software one). Software vertex processing is // specified since we know it will work on all cards. On cards that support // hardware vertex processing, though, we would see a big performance gain // by specifying hardware vertex processing. renderInterface->CreateDevice( D3DADAPTER_DEFAULT, D3DDEVTYPE_HAL, hwindows[0], D3DCREATE_SOFTWARE_VERTEXPROCESSING, &deviceConfig, &renderDevice ); this->swapChain = new LPDIRECT3DSWAPCHAIN9[wMan->getWindows().size()]; this->renderDevice->GetSwapChain(0, &swapChain[0]); for (int i = 0; i < wMan->getWindows().size(); ++i) { renderDevice->CreateAdditionalSwapChain(&deviceConfig, &swapChain[i]); } renderDevice->SetRenderState(D3DRS_CULLMODE, D3DCULL_CCW); // Set cullmode to counterclockwise culling to save resources renderDevice->SetRenderState(D3DRS_AMBIENT, 0xffffffff); // Turn on ambient lighting renderDevice->SetRenderState(D3DRS_ZENABLE, TRUE); // Turn on the zbuffer } void RAT_RendererDX9::CleanUp() { renderDevice->Release(); renderInterface->Release(); } void RAT_RendererDX9::Render(int argI) { // Clear the backbuffer to a blue color renderDevice->Clear( 0, NULL, D3DCLEAR_TARGET, D3DCOLOR_XRGB( 0, 0, 255 ), 1.0f, 0 ); LPDIRECT3DSURFACE9 backBuffer = NULL; // Set draw target this->swapChain[argI]->GetBackBuffer(0, D3DBACKBUFFER_TYPE_MONO, &backBuffer); this->renderDevice->SetRenderTarget(0, backBuffer); // Begin the scene renderDevice->BeginScene(); // End the scene renderDevice->EndScene(); swapChain[argI]->Present(NULL, NULL, hwindows[argI], NULL, 0); } void RAT_RendererDX9::ShowWin() { for (int i = 0; i < wMan->getWindows().size(); ++i) { ShowWindow( hwindows[i], SW_SHOWDEFAULT ); UpdateWindow( hwindows[i] ); // Enter the message loop MSG msg; while( GetMessage( &msg, NULL, 0, 0 ) ) { if (PeekMessage( &msg, NULL, 0U, 0U, PM_REMOVE ) ) { TranslateMessage( &msg ); DispatchMessage( &msg ); } else { Render(i); } } } } } LRESULT CALLBACK MsgProc( HWND hWnd, UINT msg, WPARAM wParam, LPARAM lParam ) { switch( msg ) { case WM_DESTROY: //CleanUp(); PostQuitMessage( 0 ); return 0; case WM_PAINT: //Render(); ValidateRect( hWnd, NULL ); return 0; } return DefWindowProc( hWnd, msg, wParam, lParam ); } I've made a sample function to make multiple windows: void RunSample1() { //Create the window manager. RAT_ENGINE::RAT_WindowManager* wMan = new RAT_ENGINE::RAT_WindowManager(); //Create the render manager. RAT_ENGINE::RAT_RenderManager* rMan = new RAT_ENGINE::RAT_RenderManager(); //Create a window. //This is currently needed to initialize the render manager and create a renderer. wMan->CreateRATWindow("Sample 1 - 1", 10, 20, 640, 480); wMan->CreateRATWindow("Sample 1 - 2", 150, 100, 480, 640); //Initialize the render manager. rMan->Init(wMan); //Show the window. rMan->getRenderer()->ShowWin(); } How do I get the multiple windows to work?

    Read the article

  • How can a single script attached to multiple enemies provide separate behavior for each enemy?

    - by Syed
    I am making a TD game and now stucked at multiple enemies using same script. All is well with scripts attached with one enemy only. Problem is in running multiple enemies. Here is the overview. I have a Enemy object with which I have attached a 'RunEnemy' script. Flow of this script is: RunEnemy.cs: PathF p; p = gameObject.GetComponent<PathF>(); //PathF is a pathfinding algo which has 'search; function which returns a array of path from starting position PathList = p.search(starting position); //------------------------------- if(PathList != null) { //if a way found! if(moving forward) transform.Translate(someXvalue,0,0); //translates on every frame until next grid point else if(moving back) transform.Translate(0,someXvalue,0); ...and so on.. if(reached on next point) PathList = p.search(from this point) //call again from next grid point so that if user placed a tower enemy will run again on the returned path } Now I have attached this script and "PathF.cs" to a single enemy which works perfect. I have then made one more enemy object and attached both of these script to it as well, which is not working they both are overlapping movements. I can't understand why, I have attached these scripts on two different gameobjects but still their values change when either enemy changes its value. I don't want to go with a separate script for each enemy because there would be 30 enemies in a scene. How can I fix this problem?

    Read the article

  • How can I author objects with perspective that fit into a tile-based map but span multiple tiles?

    - by Growler
    I'm creating a tilemap city and trying to figure out the most efficient way to create unique building scenes. The trick is, I need to maintain a sort of 2D, almost-top-down perspective, which is hard to do with buildings or large objects that span multiple tiles. I've tried doing three buildings at a time, and mixing and matching the base layer and colors, like this: This creates a weird overlapping effect, and also doesn't seem that efficient from a production standpoint. But it was the best way to have shadows appear correctly on the neighboring buildings. I'm wondering if modular buildings would be the way to go? That way I can mix and match any set of buildings together as tiles: I guess I would have to risk some perspective and shadowing to get the buildings to align correctly. What sort of authoring process could I use to allow me to create a variety of buildings (or other objects) that maintain this perspective while spanning multiple tiles worth of screen space? Would you recommend creating blank buildings, and then affixing art overlays as necessary to make the buildings unique? Or should they be directly part of the building tile (for example, create a separate tileset of buildings signs and colorings)?

    Read the article

  • Given a database table where multiple rows have the same values and only the most recent record is to be returned

    - by Jim Lahman
    I have a table where there are multiple records with the same value but varying creation dates.  A sample of the database columns is shown here:   1: select lot_num, to_char(creation_dts,'DD-MON-YYYY HH24:MI:SS') as creation_date 2: from coil_setup 3: order by lot_num   LOT_NUM                        CREATION_DATE        ------------------------------ -------------------- 1435718.002                    24-NOV-2010 11:45:54 1440026.002                    17-NOV-2010 06:50:16 1440026.002                    08-NOV-2010 23:28:24 1526564.002                    01-DEC-2010 13:14:04 1526564.002                    08-NOV-2010 22:39:01 1526564.002                    01-NOV-2010 17:04:30 1605920.003                    29-DEC-2010 10:01:24 1945352.003                    14-DEC-2010 01:50:37 1945352.003                    09-DEC-2010 04:44:22 1952718.002                    25-OCT-2010 09:33:19 1953866.002                    20-OCT-2010 18:38:31 1953866.002                    18-OCT-2010 16:15:25   Notice that there are multiple instances of of the same lot number as shown in bold. To only return the most recent instance, issue this SQL statement: 1: select lot_num, to_char(creation_date,'DD-MON-YYYY HH24:MI:SS') as creation_date 2: from 3: ( 4: select rownum r, lot_num, max(creation_dts) as creation_date 5: from coil_setup group by rownum, lot_num 6: order by lot_num 7: ) 8: where r < 100  LOT_NUM                        CREATION_DATE        ------------------------------ -------------------- 2019416.002                    01-JUL-2010 00:01:24 2022336.003                    06-OCT-2010 15:25:01 2067230.002                    01-JUL-2010 00:36:48 2093114.003                    02-JUL-2010 20:10:51 2093982.002                    02-JUL-2010 14:46:11 2093984.002                    02-JUL-2010 14:43:18 2094466.003                    02-JUL-2010 20:04:48 2101074.003                    11-JUL-2010 09:02:16 2103746.002                    02-JUL-2010 15:07:48 2103758.003                    11-JUL-2010 09:02:13 2104636.002                    02-JUL-2010 15:11:25 2106688.003                    02-JUL-2010 13:55:27 2106882.003                    02-JUL-2010 13:48:47 2107258.002                    02-JUL-2010 12:59:48 2109372.003                    02-JUL-2010 20:49:12 2110182.003                    02-JUL-2010 19:59:19 2110184.003                    02-JUL-2010 20:01:03

    Read the article

  • What would be a good topic for research on "edge of multiple processors / computers programming" topic?

    - by Kabumbus
    This is a subjective discussion so we can express our dreams and hopes here. A "topic" must be like a task with point to have as end result a software poduct. A "topic" must be mainly about "Software engineering", "Algorithm and data structure concepts" and perhaps "Design patterns". I mean let us try to look what is not already there? What can be developed in fiew month and give a breakthrue / start a new leap / show somethig not realized before in science of f multiple computers programming? What i see is already there: LAN / wire and other infrastractural programms for connecting on device level MPI/ Bit torrent/Jabber protocols / APIs / servers for messaging on top Boost and analogs on evry OS in most languages for multithreading there are lots of CUDA like on computer frameworks for fast calculating on computers GPUs What I personally do not see out there is a crossplatform framework for multiple processes interaction. Meaning one that would allow easy creation of multyple processes running in paralell inside one hoster app on one machine. In level not harder than needed for threads creation (so no seprate server apps - just one lib doing it all) Is there ny such lib and what can you propose for research topic?

    Read the article

  • Routing multiple static IPs from ISP at the cable modem?

    - by Jakobud
    I'm taking over IT responsibilities for a previous IT guy. We have a 50mb cable modem connection from Comcast along with 5 static IP addresses: XXX.XXX.XXX.180 XXX.XXX.XXX.181 XXX.XXX.XXX.182 XXX.XXX.XXX.183 XXX.XXX.XXX.184 We are in the process of replacing our firewall machine. Currently the firewall box is the only thing connected to the cable modem. However the cable modem has multiple ethernet ports on it, similarly to a router. I have assembled a new firewall machine and its time to start testing and configuring it. So that means that I also need it plugged into the cable modem (remember it has multiple ethernet ports on it). So now with multiple computer plugged into the cable modem, how does the cable modem know where to route the traffic? If some request on the internet is made to XXX.XXX.XXX.181, which goes to our cable modem, how does the cable modem know which connected computer that traffic is supposed to be sent? Looking at the web interface for the cable modem, there doesn't seem to be anything special setup on it with regards to routing or NATing IP addresses. Is that because when there is only one computer connected to the modem, all traffic is sent to it by default? Now that I am going to (temporarily) have multiple computers plugged into the cable modem, do I need to specify routing or NAT rules on the modem itself? I am going to speak to Comcast about this next, but I figured I'd ask here first just so I can get a better grasp on how this type of thing generally plays out.

    Read the article

  • VMware networking - PortChannel or not?

    - by dunxd
    My ESX hosts each have 8 NICS. I have set up 2 NICs for our iSCSI SAN - each is connected to a different SAN switch. 2 NICs are set up for vMotion and Service Console - these are each connected to a different core switch (ports are trunked with VLANs dedicated to vMotion and Management) I now have four ports left over. Currently we have these set up each going into our default VLAN. Two NICs are connected to one core-switch and two are connected to the other. We decided to aggregate the connections to each switch - so they are teamed at the vswitch end, and port channelled at the physical switch end. I am now reading that port channelling these connections is not particularly useful, perhaps even over complicating things. Is there a particular problem with using port channels for VMware? What method provides the best balance between redundancy and performance?

    Read the article

  • Oracle RAC interconnect in a Dell M1000e Blade Enclosure

    - by Antitribu
    We are looking at a Dell M1000e enclosure and appropriate Blades with 4 NICs each. We are planning on running Linux/Oracle 11g RAC on two blades, storage will be handled on an iSCSI SAN for which two NICs (via passthrough) will be connected leaving us with two NICs (via blade centre switches). We would like to have an interconnect (obviously) , an external IP and an internal IP. Would best practice be to: bond the remaining two interfaces and VLAN as appropriate to provide three virtual interfaces? run the interconnect on one interface and VLAN the external/internal interfaces? purchase a blade with more NICs as the above is a terrible idea? Another option? Please feel free to point out the blindingly obvious or to relevant documentation on support.oracle. I am specifically interested in supported configurations and best practices. Thanks!

    Read the article

  • Best NIC config when virtual servers need iSCSI storage?

    - by icky2000
    I have a Windows 2008 server running Hyper-V. There are 6 NICs on the server configured like this: NIC01 & NIC02: teamed administrative interface (RDP, mgmt, etc) NIC03: connected to iSCSI VLAN #1 NIC04: connected to iSCSI VLAN #2 NIC05: dedicated to one virtual switch for VMs NIC06: dedicated to another virtual switch for VMs The iSCSI NICs are used obviously for storage to host the VMs. I put half the VMs on the host on the switch assigned to NIC05 and the other half on the switch assigned to NIC06. We have multiple production networks that the VMs could appear on so the switch ports that NIC05 & NIC06 are connected to are trunked and we then tag the NIC on the VM for the appropriate VLAN. No clustering on this host. Now I wish to assign some iSCSI storage direct to a VM. As I see it I have 2 options: Add the iSCSI VLANs to the trunked ports (NIC05 and NIC06), add two NICs to the VM that needs iSCSI storage, and tag them for the iSCSI VLANs Create two additional virtual switches on the host. Assign one to NIC03 and one to NIC04. Add two NICs to the VM that needs iSCSI storage and let them share that path to the SAN with the host. I'm wondering about how much overhead the VLAN tagging in Hyper-V has and haven't seen any discussion about that. I'm also a bit concerned that something funky on the iSCSI-connected VM could saturate the iSCSI NICs or cause some other problem that could threaten storage access for the entire host which would be bad. Any thoughts or suggestions? How do you configure your hosts when VMs connect direct to iSCSI?

    Read the article

  • WNDR3700 Router + Cisco SG200-08 + LACP + Dual Uplink

    - by kobaltz
    Background I have a storage server that has several virtual machine images stored on them. I would store them locally, but I have limited space on my desktop (using SSD storage). I would like to increase the bandwidth between the desktop and the storage server by using two NICs on each computer. My original configuration allowed about 55MBps between the desktop and storage server. This storage server also has several TBs of documents, pictures, movies, vms, and ISO/programs. The storage server has 8 1.5TB hard drives in a RAID 10 configuration with a hardware RAID controller. The benchmarks on the RAID 10 are about 300MBps. Configuration In short, I am trying to bridge my switch and router. The switch is a small 8 port Cisco smart switch that supports 802.3ad LACP. I have two computers plugged into the switch, each with 2 Intel Gigabit NICs. The first computer is a Windows 7 machine that has the Intel ANS software installed. I have LACP configured with the computer and now show 3 NICs (2 Physical + 1 TEAM Virtual @ 2Gbps). It looks like this computer is configured correctly. I trunked the two ports that this computer is plugged into with the switch's web interface. The second computer is a homebrew storage box running debian. I also have the bonding enabled on this machine and the switch configured with LACP. Without having the WNDR3700 router in the picture yet, I am able to communicate between the Windows 7 machine and the debian box since they both have static IP addresses. With LACP enabled on both machines I am getting about 106-108MBps speeds. Issue I plug in a network cable from the switch into the router and enable DHCP on the desktop. I saw no need to have a static address on the desktop. My transfer rates are still from 106MBps-108MBps. While this is still a boost, I am trying to figure out how to get about 140-180MBps. I am thinking that I need to increase the bandwidth from the router to the switch. My switch allows 4 groups for port trunking. I plugged in a second network cable from the router to the switch. My question is, what is the proper way to fix this issue. Should I port trunk the two ports that are going from the switch to the router? Keep in mind that the router is a WNDR3700 and is unsure whether or not it supports LACP. I do have OpenWRT installed on the router, but it still wasn't clear in any documentation that I found if it supported 802.3ad LACP standards. I am also wondering if there needs to be anything changed within the Cisco settings. [Edit] - Corrected some numbers, wasn't really paying attention. It looks like the speeds though at least two NICs are bonded with LACP is still reaching the max bandwidth of one port. Is there a way to configure the switch so that I can increase this bandwidth? Also, on the storage server, I had a couple of extra NICs laying around and threw them on there as well. Another EDIT and More Findings I happened to look at the traffic of each individual NIC and think that I see the problem. I tested with a simple transfer for a 4GB file. I noticed that only one of the NICs was taking the load of the traffic. I then copied the file back to the Storage Server and noticed that the other NIC was sending out the traffic. I have 802.3ad LACP enabled on the two NICs and I see that it gets enabled dynamically on the switch's interface. Should I be using Static Link Aggregation?

    Read the article

  • Multiple classes in a single .cs file - good or bad?

    - by Sergio
    Is it advisable to create multiple classes within a .cs file or should each .cs file have an individual class? For example: public class Items { public class Animal { } public class Person { } public class Object { } } Dodging the fact for a minute that this is a poor example of good architecture, is having more than a single class in a .cs file a code smell?

    Read the article

  • How can I use multiple meshes per entity without breaking one component of a single type per entity?

    - by Mathias Hölzl
    We are just switching from a hierarchy based game engine to a component based game engine. My problem is that when I load a model which has has a hierarchy of meshes and the way I understand is that a entity in a component based system can not have multiple components of the same type, but I need a "meshComponent" for each mesh in a model. So how could I solve this problem. On this side they implemented a Component based game engine: http://cowboyprogramming.com/2007/01/05/evolve-your-heirachy/

    Read the article

  • Multiple Depends/Recommends/[…] in a control file?

    - by miK
    Is it possible to have multiple lines for any type of field in a dpkg control file? This is not about line continuation, but e.g. Depends interspersed with Recommends like so: Depends: git, etckeeper, apt-file Recommends: equivs Depends: mplayer, pidgin, dlocate, pwsafe, ciso Recommends: aria2 And so on. Is this allowed, is it unspecified (and some tool is going to cough on it) or is it explicitly forbidden? (Couldn't find anything in debian-policy, either)

    Read the article

  • Can a NodeJS webserver handle multiple hostnames on the same IP?

    - by Matthew Patrick Cashatt
    I have just begun learning NodeJS and LOVE it so far. I have set up a Linux box to run it and, in learning to use the event-driven model, I am curious if I can use a common IP for multiple domain names. Could I point, for example, www.websiteA.com, www.websiteB.com, and www.websiteC.com all to the same IP (node webserver) and then route to the appropriate source files based on the request? Would this cause certain doom when it came to scaling to any reasonable size?

    Read the article

  • Should I use multiple column primary keys or add a new colum?

    - by Covar
    My current database design makes use of a multiple column primary key to use existing data (that would be unique anyway) instead of creating an additional column assigning each entry an arbitrary key. I know that this is allowed, but was wondering if this is a practice that I might want to use cautiously and possibly avoid (much like goto in C). So what are some of the disadvantages I might see in this approach or reasons I might want a single column key?

    Read the article

< Previous Page | 224 225 226 227 228 229 230 231 232 233 234 235  | Next Page >