  • Online File Sharing that acts just like LAN shared drives, etc.

    - by Dayton Brown
    Hi All, Have a small business client that wants to move their current file share to the web. Specs are as follows, 20 to 30 GB of space, file sizes are normal (nothing more than 50 to 100 mb) 3 users ideal solution would be exact same functionality as windows explorer. CHEAP!!! But not super cheap. I would like to keep it around $20 per user per month. I've explored a bunch of solutions, but they are all a bit on the complicated side. Thanks in advance for the recommendations.

    Read the article

  • Viruses on removable drives - how may they get into the system?

    - by osgx
    Hello When I inserting flash drive of my friend, how can I check that it is safe from infecting me with a viruses? Autorun.inf. This can be disabled with Shift while inserting or in registry anything other way of how can trojan get into my comp? folder.htt - seems to be disabled in modern XP Considering the default Windows XP SP2-SP3, flash is opened with Explorer.

    Read the article

  • Terrible Performance with SATA Drives on Dell PowerEdge, steps to troubleshoot?

    - by Tom
    I had asked this question earlier and the question went missing so here it is again. Bought a DELL Poweredge 2950 to use as in-house QA Server. Disk performance is beyond terrible, 1000-4000 ms response time on the drive with our SQL Server database .mdf. Sql Server disk queue upwards of 300 at times. I'm a software guy, can anyone help me with steps to determine the issue? I don't know what RAID controller it has, how can I determine that? I'm speculating it could be BIOS issue. Perhaps the server used to have another kind of drive in it and when I added SATA the ??? buffer size is wrong??? Perhaps I chose wrong options (chose defaults) when setting up the RAID 1 arrays? I thought RAID 1 was a performance array?

    Read the article

  • Proper way to connect SATA and IDE Hard drives together?

    - by Bartek
    I have an old IDE hard drive that has a broken Windows install on it. It just won't boot up, and I've tried a variety of solutions. That's fine, I really just need a few files on the hard drive. I have a computer that uses a SATA connected hard drive. It's a working PC. I would like to connect the old IDE hard drive to that compute and basically browse through the file system, grab the files, and copy them to my existing computer. My problem is with my few attempts to connect the IDE drive I would get Boot Disk Failures and so forth. I guess it's trying to boot from the IDE but I'm not really sure. Any help would be appreciated, Thanks!

    Read the article

  • Are there any USB flash drives or SD cards which use RAID or redundant storage for additional reliability?

    - by Luke Dennis
    I'm looking to get a fault-tolerant USB flash drive, which saves data to multiple independent locations, whether using RAID or some other means to back up data. Has a product like this ever been created, or are my only options to hack something together? (By the way: I'm aware that RAID doesn't prevent data corruption from software or the file system. I'm just looking for something that can handle one of the memory sticks going dead.)

    Read the article

  • pdflush hanging on Amazon EBS drives when using multi-GB files - any workaround?

    - by rhh
    Hello, When I run gunzip on a 1.7GB file (which generates an 8GB file) on an EBS volume, pdflush freezes after gunzip runs and the CPU hangs indefinitely at 100% IO Wait. Here's the output from 'ps aux | grep pdflush'. Note the D status root 87 0.0 0.0 0 0 ? D 06:18 0:00 pdflush root 88 0.0 0.0 0 0 ? D 06:18 0:00 pdflush The only solution is to kill the pdflush processes. The processes don't die immediately either. This problem is repeatable and happens with new instances. I'm running 2xlarge instances and I have way more RAM free than is being used (i.e. /proc/meminfo shows 20+GB MemFree) Has anyone found a workaround to this problem in the past? Thanks for any thoughts. Robert

    Read the article

  • Why do firewire drives on Mac OS cause processes to go into uninterruptible wait?

    - by akraut
    I have a Western Digital My Passport Studio external hard drive. It works with either Firewire 800 or USB 2.0. I've noticed that when I have it connected to Firewire, after a few hours, processes on my Mac start to go into an uninterruptible wait state. Eventually the system becomes so hard locked that I can't even shut it down. I have Spotlight indexing of the drive disabled, and the mds process seems to be the one that triggers this eventual system collapse.

    Read the article

  • Would SSD drives benefit from a non-default allocation unit size?

    - by davebug
    The default allocation unit size recommended when formatting a drive in our current set-up is 4096 bytes. I understand the basics of the pros and cons of larger and smaller sizes (performance boost vs. space preservation) but it seems the benefits of a solid state drive (seek times massively lower than hard disks) may create a situation where a much smaller allocation size is not detrimental. Were this the case it would at least partially help to overcome the disadvantage of SSD (massively higher prices per GB). Is there a way to determine the 'cost' of smaller allocation sizes specifically related to seek times? Or are there any studies or articles recommending a change from the default based on this newer tech? (Assume the most average scattering of sizes program files, OS files, data, mp3s, text files, etc.)

    Read the article

  • How to ignore hard drives size with Windows Server Backup (Win-2008) restore?

    - by Jason
    I used Windows Server Backup to backup my 640GB boot drive. Only about 30GB is used, and the backup was very fast. Now I am trying to restore the image to a 500GB hard drive but it is saying that the drive is too small... even though I only had 30GB on the original backup. How do I overide this and have the restore ignore that I only have a 500GB drive? If I can't, then I can't restore the hard drive with anything except one that is equal to or bigger than the original hard drive - which would be a real bummer.

    Read the article

  • ubuntu not detecting CDdrives

    - by Mirage
    Ihave insatlled ubuntu 10.4 on my compuer with 6 cd drives. Now initiallyi had window server 2008 and i had to install marvel raid sata controller and then my window detected all 6 drives. Now ubuntu is detecting only 3 drives and i have not found marvell drivers for ubuntu bt i have drives for window 2008. Now my question is if i have vrtual machine inside ubuntu using vmware workstation and i install that driver. then can VM dtect thse 6 drives or host has to detect those drives first to make VMs use that Ubuntu shows this thing from terminal *-cdrom:0 description: DVD-RAM writer product: DVDRAM GSA-H10N vendor: HL-DT-ST physical id: 0.0.0 bus info: scsi@0:0.0.0 logical name: /dev/cdrom2 logical name: /dev/cdrw2 logical name: /dev/dvd2 logical name: /dev/dvdrw2 logical name: /dev/scd0 logical name: /dev/sr0 version: JL10 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 status=nodisc *-cdrom:1 description: DVD writer product: DVDRRW GWA-4164B vendor: HL-DT-ST physical id: 0.1.0 bus info: scsi@0:0.1.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/scd1 logical name: /dev/sr1 version: 1.01 serial: [HL-DT-STDVDRRW GWA-4164B1.0105/05/12 capabilities: removable audio cd-r cd-rw dvd dvd-r configuration: ansiversion=5 status=nodisc Is t detecting all drives or thise local names just same

    Read the article

  • Dell R320 RAID 10 with CacheCade

    - by Geekman
    I'm looking for a higher-performance build for our 1RU Dell R320 servers, in terms of IOPS. Right now I'm fairly settled on: 4 x 600 GB 3.5" 15K RPM SAS RAID 1+0 array This should give good performance, but if possible, I want to also add an SSD Cache into the mix, but I'm not sure if there's enough room? According to the tech-specs, there's only up to 4 total 3.5" drive bays available. Is there any way to fit at least a single SSD drive along-side the 4x3.5" drives? I was hoping there's a special spot to put the cache SSD drive (though from memory, I doubt there'd be room). Or am I right in thinking that the cache drives are simply drives plugged in "normally" just as any other drive, but are nominated as CacheCade drives in the PERC controller? Are there any options for having the 4x600GB RAID 10 array, and the SSD cache drive, too? Based on the tech-specs (with up to 8x2.5" drives), maybe I need to use 2.5" SAS drives, leaving another 4 bays spare, plenty of room for the SSD cache drive. Has anyone achieved this using 3.5" drives, somehow?

    Read the article

  • How to set up RAID-0 first time on new PC?

    - by jasondavis
    I have built basic PC's in the past but have never used a RAID array at all. SO now I am buying parts to build my new PC, it will be an intel i7 processor. My motherboard will have RAID support which I will use instead of an aftermarket raid controller for now. Also I plan to use 2 SSD drives in RAID-0 for my windows 7 OS. (Please note that I am aware of the issues with doing this, including lack of TRIM support when using RAID with SSD drives. I am OK with it not working as I can just re[place the drives in a year or so or wheneer they become more sluggish). SO here is my question part. If I assemble the motherboard, PSU, processor, RAM, vidm card, etc and then go to turn the PC on, it will have the 2 SSD drives hooked up. so I assume I will then soon the BIOS screen before I install windows? How to I go about making the 2 drives work in RAID-0 at this point? I do the raid part before installing my OS right? Please help with the steps involved from assembling the parts of the PC and then turning it on, to the part of getting the RAID-0 set up between the 2 drives and then installing my windows 7 OS from a Optical drive? Please help, all advice, instructions, tips appreciated as long as on topic. I do not need to be told that this is a bad idea as far as if 1 drive fails I losse it all, I plan on having a disk IMAGE to be able to restore my OS and software to a new set of drives at anytime needed in the event of drive failure. Same goes for lack of TRIM support. Thanks for reading and help =)

    Read the article

  • ubuntu VM not detecting CDdrives

    - by Mirage
    Ihave insatlled ubuntu 10.4 on my compuer with 6 cd drives. Now initiallyi had window server 2008 and i had to install marvel raid sata controller and then my window detected all 6 drives. Now ubuntu is detecting only 3 drives and i have not found marvell drivers for ubuntu bt i have drives for window 2008. Now my question is if i have vrtual machine inside ubuntu using vmware workstation and i install that driver. then can VM dtect thse 6 drives or host has to detect those drives first to make VMs use that Ubuntu shows this thing from terminal *-cdrom:0 description: DVD-RAM writer product: DVDRAM GSA-H10N vendor: HL-DT-ST physical id: 0.0.0 bus info: scsi@0:0.0.0 logical name: /dev/cdrom2 logical name: /dev/cdrw2 logical name: /dev/dvd2 logical name: /dev/dvdrw2 logical name: /dev/scd0 logical name: /dev/sr0 version: JL10 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 status=nodisc *-cdrom:1 description: DVD writer product: DVDRRW GWA-4164B vendor: HL-DT-ST physical id: 0.1.0 bus info: scsi@0:0.1.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/scd1 logical name: /dev/sr1 version: 1.01 serial: [HL-DT-STDVDRRW GWA-4164B1.0105/05/12 capabilities: removable audio cd-r cd-rw dvd dvd-r configuration: ansiversion=5 status=nodisc Is t detecting all drives or thise local names just same

    Read the article

  • Monitor your Hard Drive’s Health with Acronis Drive Monitor

    - by Matthew Guay
    Are you worried that your computer’s hard drive could die without any warning?  Here’s how you can keep tabs on it and get the first warning signs of potential problems before you actually lose your critical data. Hard drive failures are one of the most common ways people lose important data from their computers.  As more of our memories and important documents are stored digitally, a hard drive failure can mean the loss of years of work.  Acronis Drive Monitor helps you avert these disasters by warning you at the first signs your hard drive may be having trouble.  It monitors many indicators, including heat, read/write errors, total lifespan, and more. It then notifies you via a taskbar popup or email that problems have been detected.  This early warning lets you know ahead of time that you may need to purchase a new hard drive and migrate your data before it’s too late. Getting Started Head over to the Acronis site to download Drive Monitor (link below).  You’ll need to enter your name and email, and then you can download this free tool. Also, note that the download page may ask if you want to include a trial of their for-pay backup program.  If you wish to simply install the Drive Monitor utility, click Continue without adding. Run the installer when the download is finished.  Follow the prompts and install as normal. Once it’s installed, you can quickly get an overview of your hard drives’ health.  Note that it shows 3 categories: Disk problems, Acronis backup, and Critical Events.  On our computer, we had Seagate DiskWizard, an image backup utility based on Acronis Backup, installed, and Acronis detected it. Drive Monitor stays running in your tray even when the application window is closed.  It will keep monitoring your hard drives, and will alert you if there’s a problem. Find Detailed Information About Your Hard Drives Acronis’ simple interface lets you quickly see an overview of how the drives on your computer are performing.  If you’d like more information, click the link under the description.  Here we see that one of our drives have overheated, so click Show disks to get more information. Now you can select each of your drives and see more information about them.  From the Disk overview tab that opens by default, we see that our drive is being monitored, has been running for a total of 368 days, and that it’s health is good.  However, it is running at 113F, which is over the recommended max of 107F.   The S.M.A.R.T. parameters tab gives us more detailed information about our drive.  Most users wouldn’t know what an accepted value would be, so it also shows the status.  If the value is within the accepted parameters, it will report OK; otherwise, it will show that has a problem in this area. One very interesting piece of information we can see is the total number of Power-On Hours, Start/Stop Count, and Power Cycle Count.  These could be useful indicators to check if you’re considering purchasing a second hand computer.  Simply load this program, and you’ll get a better view of how long it’s been in use. Finally, the Events tab shows each time the program gave a warning.  We can see that our drive, which had been acting flaky already, is routinely overheating even when our other hard drive was running in normal temperature ranges. Monitor Acronis Backups And Critical Errors In addition to monitoring critical stats of your hard drives, Acronis Drive Monitor also keeps up with the status of your backup software and critical events reported by Windows.  You can access these from the front page, or via the links on the left hand sidebar.  If you have any edition of any Acronis Backup product installed, it will show that it was detected.  Note that it can only monitor the backup status of the newest versions of Acronis Backup and True Image. If no Acronis backup software was installed, it will show a warning that the drive may be unprotected and will give you a link to download Acronis backup software.   If you have another backup utility installed that you wish to monitor yourself, click Configure backup monitoring, and then disable monitoring on the drives you’re monitoring yourself. Finally, you can view any detected Critical events from the Critical events tab on the left. Get Emailed When There’s a Problem One of Drive Monitor’s best features is the ability to send you an email whenever there’s a problem.  Since this program can run on any version of Windows, including the Server and Home Server editions, you can use this feature to stay on top of your hard drives’ health even when you’re not nearby.  To set this up, click Options in the top left corner. Select Alerts on the left, and then click the Change settings link to setup your email account. Enter the email address which you wish to receive alerts, and a name for the program.  Then, enter the outgoing mail server settings for your email.  If you have a Gmail account, enter the following information: Outgoing mail server (SMTP): smtp.gmail.com Port: 587 Username and Password: Your gmail address and password Check the Use encryption box, and then select TLS from the encryption options.   It will now send a test message to your email account, so check and make sure it sent ok. Now you can choose to have the program automatically email you when warnings and critical alerts appear, and also to have it send regular disk status reports.   Conclusion Whether you’ve got a brand new hard drive or one that’s seen better days, knowing the real health of your it is one of the best ways to be prepared before disaster strikes.  It’s no substitute for regular backups, but can help you avert problems.  Acronis Drive Monitor is a nice tool for this, and although we wish it wasn’t so centered around their backup offerings, we still found it a nice tool. Link Download Acronis Drive Monitor (registration required) Similar Articles Productive Geek Tips Quick Tip: Change Monitor Timeout From Command LineAnalyze and Manage Hard Drive Space with WinDirStatMonitor CPU, Memory, and Disk IO In Windows 7 with Taskbar MetersDefrag Multiple Hard Drives At Once In WindowsFind Your Missing USB Drive on Windows XP TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips HippoRemote Pro 2.2 Xobni Plus for Outlook All My Movies 5.9 CloudBerry Online Backup 1.5 for Windows Home Server Windows 7’s WordPad is Actually Good Greate Image Viewing and Management with Zoner Photo Studio Free Windows Media Player Plus! – Cool WMP Enhancer Get Your Team’s World Cup Schedule In Google Calendar Backup Drivers With Driver Magician TubeSort: YouTube Playlist Organizer

    Read the article

  • How do I programmatically create a bootable CD?

    - by Nicholas Flynt
    I'm using a barebones tutorial as the basis for an OS I'm working on, and it seems to be an older tutorial: it has be compiling the kernel down to a floppy image, and then loading it with GRUB. Basically, I still want to use GRUB, but I'd like to have my OS run from a CD instead. The main reason is that I don't actually have a real floppy drive available (I'm testing in VirtualBox currently) and I thus have no way to test my OS on real hardware. I've been poking around on the net, and I can find lots of utilities that create a bootable CD from a floppy image, but these all seem to require an actual floppy drive, plus it's not really what I'm looking for. I'd like to be able to end up with a bootable CD during my make step ideally, without needing to first place the image on a floppy, which seems rather pointless. I guess the easy way to answer this: How do I set up GRUB to read my kernel image from a CD? Will I need a special utility to do this from Windows? (The kernel can't compile itself yet, that's not for a looong while) Thanks!

    Read the article

  • Help in building an 16 bit os

    - by Barshan Das
    I am trying to build an old 16 bit dos like os. My bootloader code: ; This is not my code. May be of Fritzos. I forgot the source. ORG 7c00h jmp Start drive db 0 msg db " Loader Initialization",0 msg2 db "ACos Loaded",0 print: lodsb cmp al, 0 je end mov ah, 0Eh int 10h jmp print end: ret Start: mov [ drive ], dl ; Get the floppy OS booted from ; Update the segment registers xor ax, ax ; XOR ax mov ds, ax ; Mov AX into DS mov si,msg call print ; Load Kernel. ResetFloppy: mov ax, 0x00 ; Select Floppy Reset BIOS Function mov dl, [ drive ] ; Select the floppy ADos booted from int 13h ; Reset the floppy drive jc ResetFloppy ; If there was a error, try again. ReadFloppy: mov bx, 0x9000 ; Load kernel at 9000h. mov ah, 0x02 ; Load disk data to ES:BX mov al, 17 ; Load two floppy head full's worth of data. mov ch, 0 ; First Cylinder mov cl, 2 ; Start at the 2nd Sector to load the Kernel mov dh, 0 ; Use first floppy head mov dl, [ drive ] ; Load from the drive kernel booted from. int 13h ; Read the floppy disk. jc ReadFloppy ; Error, try again. ; Clear text mode screen mov ax, 3 int 10h ;print starting message mov si,msg2 call print mov ax, 0x0 mov ss, ax mov sp, 0xFFFF jmp 9000h ; This part makes sure the bootsector is 512 bytes. times 510-($-$$) db 0 ;bootable sector signature dw 0xAA55 My example kernel code: asm(".code16\n"); void putchar(char); int main() { putchar('A'); return 0; } void putchar(char val) { asm("movb %0, %%al\n" "movb $0x0E, %%ah\n" "int $0x10\n" : :"r"(val) ) ; } This is how I compile it : nasm -f bin -o ./bin/boot.bin ./source/boot.asm gcc -nostdinc -fno-builtin -I./include -c -o ./bin/kernel.o ./source/kernel.c ld -Ttext=0x9000 -o ./bin/kernel.bin ./bin/kernel.o -e 0x0 dd if=/dev/zero of=./bin/empty.bin bs=1440K count=1 cat ./bin/boot.bin ./bin/kernel.bin ./bin/empty.bin|head -c 1440K > ./bin/os rm ./bin/empty.bin and I run it in virtual machine. When I make the putchar function ( in kernel code ) for constant value ....i.e like this: void putchar() { char val = 'A'; asm("movb %0, %%al\n" "movb $0x0E, %%ah\n" "int $0x10\n" : :"r"(val) ) ; } then it works fine. But when I pass argument to it ( That is in the previous code ) , then it prints a space for any character. What should I do?

    Read the article

  • how to mount partitions from USB drives in Windows using Delphi?

    - by user569556
    Hi. I'm a Delphi programmer. I want to mount all partitions from USB drives in Windows (XP). The OS is doing this automatically but there are situations when such a program is useful. I know how to find if a drive is on USB or not. My code so far is: type STORAGE_QUERY_TYPE = (PropertyStandardQuery = 0, PropertyExistsQuery, PropertyMaskQuery, PropertyQueryMaxDefined); TStorageQueryType = STORAGE_QUERY_TYPE; STORAGE_PROPERTY_ID = (StorageDeviceProperty = 0, StorageAdapterProperty); TStoragePropertyID = STORAGE_PROPERTY_ID; STORAGE_PROPERTY_QUERY = packed record PropertyId: STORAGE_PROPERTY_ID; QueryType: STORAGE_QUERY_TYPE; AdditionalParameters: array[0..9] of AnsiChar; end; TStoragePropertyQuery = STORAGE_PROPERTY_QUERY; STORAGE_BUS_TYPE = (BusTypeUnknown = 0, BusTypeScsi, BusTypeAtapi, BusTypeAta, BusType1394, BusTypeSsa, BusTypeFibre, BusTypeUsb, BusTypeRAID, BusTypeiScsi, BusTypeSas, BusTypeSata, BusTypeMaxReserved = $7F); TStorageBusType = STORAGE_BUS_TYPE; STORAGE_DEVICE_DESCRIPTOR = packed record Version: DWORD; Size: DWORD; DeviceType: Byte; DeviceTypeModifier: Byte; RemovableMedia: Boolean; CommandQueueing: Boolean; VendorIdOffset: DWORD; ProductIdOffset: DWORD; ProductRevisionOffset: DWORD; SerialNumberOffset: DWORD; BusType: STORAGE_BUS_TYPE; RawPropertiesLength: DWORD; RawDeviceProperties: array[0..0] of AnsiChar; end; TStorageDeviceDescriptor = STORAGE_DEVICE_DESCRIPTOR; const IOCTL_STORAGE_QUERY_PROPERTY = $002D1400; var i: Integer; H: THandle; USBDrives: array of Byte; Query: TStoragePropertyQuery; dwBytesReturned: DWORD; Buffer: array[0..1023] of Byte; sdd: TStorageDeviceDescriptor absolute Buffer; begin SetLength(UsbDrives, 0); SetErrorMode(SEM_FAILCRITICALERRORS); for i := 0 to 99 do begin H := CreateFile(PChar('\\.\PhysicalDrive' + IntToStr(i)), 0, FILE_SHARE_READ or FILE_SHARE_WRITE, nil, OPEN_EXISTING, 0, 0); if H <> INVALID_HANDLE_VALUE then begin try dwBytesReturned := 0; FillChar(Query, SizeOf(Query), 0); FillChar(Buffer, SizeOf(Buffer), 0); sdd.Size := SizeOf(Buffer); Query.PropertyId := StorageDeviceProperty; Query.QueryType := PropertyStandardQuery; if DeviceIoControl(H, IOCTL_STORAGE_QUERY_PROPERTY, @Query, SizeOf(Query), @Buffer, SizeOf(Buffer), dwBytesReturned, nil) then if sdd.BusType = BusTypeUsb then begin SetLength(USBDrives, Length(USBDrives) + 1); UsbDrives[High(USBDrives)] := Byte(i); end; finally CloseHandle(H); end; end; end; for i := 0 to High(USBDrives) do begin // end; end. But I don't know how to access partitions on each drive and mounts them. Can you please help me? I searched before I asked and I couldn't find a working code. But if I did not properly then I'm sorry and please show me that topic. Best regards, John

    Read the article

  • Why is my machine unable to mount my SMB drives ("CIFS VFS: Error connecting to socket. Aborting operation", return code -115)?

    - by downbeat
    I have a machine running Precise (12.04 x64), and I cannot mount my SMB drives (I have 3, we'll call them public, private and download). It used to work (a week or two ago) and I didn't touch fstab! The machine hosting the shares is a commercial NAS, and I'm not seeing anything that would indicate it's an issue with the NAS. I have an older machine which I updated to Precise at the same time (both fresh installed, not dist-upgrade), so should have a very similar configuration. It is not having any problems. I am not having problems on windows machines/partitions either, only one of my Precise machines. The two machines are using identical entries in fstab and identical /etc/samba/smb.conf files. I don't think I've ever changed smb.conf (has never mattered before). My fstab entries all basically look like this: //10.1.1.111/public /media/public cifs credentials=/home/downbeat/.credentials,iocharset=utf8,uid=downbeat,gid=downbeat,file_mode=0644,dir_mode=0755 0 0 Here's the dmesg output on boot: [ 51.162198] CIFS VFS: Error connecting to socket. Aborting operation [ 51.162369] CIFS VFS: cifs_mount failed w/return code = -115 [ 51.194106] CIFS VFS: Error connecting to socket. Aborting operation [ 51.194250] CIFS VFS: cifs_mount failed w/return code = -115 [ 51.198120] CIFS VFS: Error connecting to socket. Aborting operation [ 51.198243] CIFS VFS: cifs_mount failed w/return code = -115 There are no other errors I see in the dmesg output. Originally when I ran 'testparm -s', the output contained these lines ERROR: lock directory /var/run/samba does not exist ERROR: pid directory /var/run/samba does not exist Here's the samba related programs I have installed: $ dpkg --list|grep -i samba ii libpam-winbind 2:3.6.3-2ubuntu2.3 Samba nameservice and authentication integration plugins ii libwbclient0 2:3.6.3-2ubuntu2.3 Samba winbind client library ii nautilus-share 0.7.3-1ubuntu2 Nautilus extension to share folder using Samba ii python-smbc 1.0.13-0ubuntu1 Python bindings for Samba clients (libsmbclient) ii samba-common 2:3.6.3-2ubuntu2.3 common files used by both the Samba server and client ii samba-common-bin 2:3.6.3-2ubuntu2.3 common files used by both the Samba server and client ii winbind 2:3.6.3-2ubuntu2.3 Samba nameservice integration server $ dpkg --list|grep -i smb ii dmidecode 2.11-4 SMBIOS/DMI table decoder ii libsmbclient 2:3.6.3-2ubuntu2.3 shared library for communication with SMB/CIFS servers ii python-smbc 1.0.13-0ubuntu1 Python bindings for Samba clients (libsmbclient) ii smbclient 2:3.6.3-2ubuntu2.3 command-line SMB/CIFS clients for Unix ii smbfs 2:5.1-1ubuntu1 Common Internet File System utilities - compatibility package $ dpkg --list|grep -i cifs ii cifs-utils 2:5.1-1ubuntu1 Common Internet File System utilities ii libsmbclient 2:3.6.3-2ubuntu2.3 shared library for communication with SMB/CIFS servers ii smbclient 2:3.6.3-2ubuntu2.3 command-line SMB/CIFS clients for Unix I originally noticed that my other machine had "libpam-winbind" and "nautilus-share" installed and the machine with the issue did not. Installing those two packages solved my errors with 'testparm -s', but did not fix my issue. Finally, I tried to purge and reinstall these packages smbclient smbfs cifs-utils samba-common samba-common-bin Still no luck. Again, it used to work; now it doesn't. Very similarly configured machine works (but some packages are out of date on the working machine). The NAS has only one interface/IP address, nmblookup works to find it's IP from it's hostname (from the machine with the issue) and it responds to a ping. Please any help would be great. I've been searching on AskUbuntu, SuperUser, ubuntuforums and plain old search engines for a week now and it's driving me crazy!

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\