  • Looking for updated BIOS for '99 Gateway in order to format/recognize >127 GB HD

    - by Jeff
    I have a '99 Gateway that's apparently too old for even Gateway to acknowledge it exists. Want to use it as a media hub and put in a 320GB HD, but it will not format above 127GB even running Win XP SP3. Read somewhere that upgrading the BIOS may do the trick, but I can't find the correct BIOS, and GW has been no help. Hoping I can just upgrade the BIOS, which is 11 years old. Any help would be much appreciated! I don't know where to look, and searches have been fruitless. System info: OS Name Microsoft Windows XP Home Edition Version 5.1.2600 Service Pack 3 Build 2600 OS Manufacturer Microsoft Corporation System Name xxxx System Manufacturer Gateway System Model TABOR_II System Type X86-based PC Processor x86 Family 6 Model 7 Stepping 3 GenuineIntel ~596 Mhz BIOS Version/Date Intel Corp. 4W4SB0X0.15A.0015.P10, 9/28/1999 SMBIOS Version 2.1 BIOS info (from a free app I located): BIOS Type: Phoenix BIOS Date: September 28th 1999 BIOS ID: 4W4SB0X0.15A.0015.P10.9909281445-None BIOS OEM: 4W4SB0X0.15A.0015.P10 Chipset: Intel 440BX/ZX rev 3 SuperIO: SMC 70x or 80x rev 0 at port 0370 Manufacturer: Gateway Motherboard: WS440BX

    Read the article

  • HP Storageworks 448 tape drive input/output error with Ubuntu

    - by Dan D
    I'm trying to set a backup to tape of a machine using flexbackup. However any attempt to write to the tape drive (via either flexbackup or just tar) results in "/dev/st0: Input/output error" The machine seems to recognise the drive (HP Storageworks Ultrium 448) and that there's a tape in it and "mt status" seems to work... "mt -f /dev/st0 rewind" or "erase" throw no errors... root@stor001:/# mt status SCSI 2 tape drive: File number=0, block number=0, partition=0. Tape block size 0 bytes. Density code 0x42 (LTO-2). Soft error count since last status=0 General status bits on (41010000): BOT ONLINE IM_REP_EN root@stor001:/# cat /proc/scsi/scsi Attached devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: HL-DT-ST Model: DVDRAM GSA-4084N Rev: KS02 Type: CD-ROM ANSI SCSI revision: 05 Host: scsi2 Channel: 00 Id: 03 Lun: 00 Vendor: HP Model: Ultrium 2-SCSI Rev: S65D Type: Sequential-Access ANSI SCSI revision: 03 "tell" does however root@stor001:/# mt -f /dev/st0 tell /dev/st0: Input/output error Based on a forum post I found, I tried: root@stor001:/# dd if=/dev/zero of=/dev/nst0 bs=1024 count=10 10+0 records in 10+0 records out 10240 bytes (10 kB) copied, 5.0815 s, 2.0 kB/s which gave the person on the forum an error but seems to work for me. If anyone has any suggestions, I'm all ears...

    Read the article

  • PXE bootable image for terminal server?

    - by HeavenCore
    We have 300 windows xp machines on cruddy old hardware across the company. With extended support for XP ending April next year we're looking into our options. Couple of options: Replace the 300 PC's with full windows 7 PC's (£100k +?) - no use of terminal server (our current model) Replace the 300 PC's with off the shelf thin clients & make use of our terminal server - Cheaper clients but Terminal Server CALS required? Keep the 300 PC's, replace windows XP with linux thin client capable of connecting to our terminal server - no hardware costs, just Terminal Server CALS required? Keep the 300 PC's - remove hard drives and make use of a PXE bootable "thin client" to connect to our terminal server If we were to choose option 4, what our the options out there? Is there any official PXE bootable thin clients for terminal server out there? If so, what are the licence requirements? Is there options we haven’t considered? There must be lots of companies out there in this situation - curious what the current trend is for this problem? Edit: Option 5 - Create a bootable Windows PE image with RDP auto start and use that as a "thin client" for our terminal server - is Windows PE licence free in such a model?

    Read the article

  • What should I do to make sure that IIS does not recycle my application?

    - by AngryHacker
    I have a WCF service app hosted in IIS. On startup, it goes and fetches a really expensive (in terms of time and cpu) resource to use as local cache. Unfortunately, IIS seems to recycle the process on a fairly regular basis. So I am trying to change the settings on the Application Pool to make sure that IIS does not recycle the application. So far, I've change the following: Limit Interval under CPU from 5 to 0. Idle Time-out under Process Model from 20 to 0. Regular Time Interval under Recycling from 1740 to 0. Will this be enough? And I have specific questions about the items I changed: What specifically does Limit Interval setting under CPU mean? Does it mean that if a certain CPU usage is exceeded, the application pool will be recycled? What exactly does "recycled" mean? Is the application completely torn down and started up again? What is the difference between "Worker Process shutdown" and "Application Pool recycling"? The documentation for the Idle Time-out under Process Model talks about shutting down the worker process. While the docs for Regular Time Interval under Recycling talk about application pool recycling. I don't quite grok the difference between the two. I thought the w3wp.exe is the worker process which runs the application pool. Can someone explain the difference to the application between the two? The reason for having IIS7 and IIS7.5 tags is because the app will run in both and hope the answers are the same between the versions. Image for reference:

    Read the article

  • Flash alternative for iBook Mac?

    - by Hunter Dolan
    I have a old Apple iBook G4 that I decided to hook up to my main TV. I like the setup because I can surf the internet on my TV now. The only thing that I can't seem to do is watch Flash videos. Apparently Flash Player 10 doesn't play nice with the iBook's graphics card's GPU, leaving all the graphics processing to the CPU which is a disaster. Others suggested downgrading to Flash Player 9, I did that, and youtube worked fine, but Hulu (The main reason I wanted to hook it up to the TV in the first place) did not. Anyone know of a Flash alternative or a Flash 10 fix for the iBook? Or even a Hulu client that doesn't require Flash. Here are my iBook's Specs Model Name: iBook G4 <br> Model Identifier: PowerBook6,5 <br> Processor Name: PowerPC G4 (1.2) <br> Processor Speed: 1.2 GHz <br> Number Of CPUs: 1 <br> L2 Cache (per CPU): 512 KB <br> Memory: 512 MB <br> Bus Speed: 133 MHz <br> Boot ROM Version: 4.8.7f1 <br> Mac OS X Version: 10.5.8 <br> PS: Don't tell me that I need to buy a new computer. I know that I would have better results with a new computer but I don't want to buy a new computer just for Hulu.

    Read the article

  • Macbook Pro Triple Boot OS X Lion, Windows 7 and Windows 8

    - by Lloyd Sparkes
    MacBook Pro (Summer 2010 Model, Basic Model) I currently have OS X Lion and Windows 7 running side by side on my MacBook Pro. However I have a need to get Windows 8 running as well in this mix (a Virtual Machine is not good enough, I need the performance). I have created a suitably sized parition (80GB) that is recognizable in Boot Camp. However every time I try to boot from the USB stick (that worked to install Windows 8 on my PC) using the latest version of rEFIt, it just boots Windows 7 and not the Windows 8 installer. I cannot start the installation within Windows 7 as it will just install over Windows 7. I'm guessing the Boot Camp emulation is doing something werid to stop the "Press any key to install Windows..." message from appearing (which should happen if the installer detects Windows is already installed (e.g. if you left your install disk in). Is there a way to get around this / force the installer to start? (Note I cannot start the Windows 7 installer either if I wanted to install a second copy of Windows 7 to upgrade to Windows 8)

    Read the article

  • cisco 2900xl - SNMP - Get mac address of device connected to an interface

    - by ankit
    Hello all, Basically what i want to do is to find out what is the mac address of a device plugged in to an interface on the switch (FastEthernet0/1 for example) reading through the switch documentaion i found out that i can configure snmp trap on it to make it notify of any new mac address the switch detects by using the command snmp-server enable traps mac-notifiction but for some reason my switch does not support this feature. the only options i see are CORE_SWITCH(config)#snmp-server enable traps ? c2900 Enable SNMP c2900 traps cluster Enable Cluster traps config Enable SNMP config traps entity Enable SNMP entity traps hsrp Enable SNMP HSRP traps snmp Enable SNMP traps vlan-membership Enable VLAN Membership traps vtp Enable SNMP VTP traps <cr> so the other way would be for me to run a cronjon on my gateway to poll the switch periodically using snmp to get new mac addresses i have looked everywhere but cant seem to find the OID that would provide me this information. any help i can get would me very much appreciated ! here's the output from "show version" on my switch Cisco Internetwork Operating System Software IOS (tm) C2900XL Software (C2900XL-C3H2S-M), Version 12.0(5.4)WC(1), MAINTENANCE INTERIM SOFTWARE Copyright (c) 1986-2001 by cisco Systems, Inc. Compiled Tue 10-Jul-01 11:52 by devgoyal Image text-base: 0x00003000, data-base: 0x00333CD8 ROM: Bootstrap program is C2900XL boot loader CORE_SWITCH uptime is 1 hour, 24 minutes System returned to ROM by power-on System image file is "flash:c2900XL-c3h2s-mz.120-5.4.WC.1.bin" cisco WS-C2912-XL (PowerPC403GA) processor (revision 0x11) with 8192K/1024K bytes of memory. Processor board ID FAB0409X1WS, with hardware revision 0x01 Last reset from power-on Processor is running Enterprise Edition Software Cluster command switch capable Cluster member switch capable 12 FastEthernet/IEEE 802.3 interface(s) 32K bytes of flash-simulated non-volatile configuration memory. Base ethernet MAC Address: 00:01:42:D0:67:00 Motherboard assembly number: 73-3397-08 Power supply part number: 34-0834-01 Motherboard serial number: FAB040843G4 Power supply serial number: DAB05030HR8 Model revision number: A0 Motherboard revision number: C0 Model number: WS-C2912-XL-EN System serial number: FAB0409X1WS Configuration register is 0xF thanks, -ankit

    Read the article

  • Memory upgrade to 8GB on unibody MacBook

    - by dlamblin
    I bought the 13" unibody MacBook one month prior to it's upgrade to become the new improved 13" unibody MacBook Pro (with unopenable battery compartment, extra 3 hours of battery life, more color gammut, SD slot, firewire 800 port, and a new 8Gb memory limit). My MacBook says it is limited to 4GB of DDR3 1066mhz memory, in 2 SO-DIMMs. But that was written back when you couldn't get 2 4GB SO-DIMMs. Now that you can get them, the very similar MacBook Pro is shipping with 4GB standard, and can be upgraded to 8GB. I've asked (Apple reps), and I'm repeatedly told that my model cannot be upgraded to 8. When I ask for the reason they alway say: "Because that's the published limit at the time your mac was built." I find this unconvincing. If they said: "Because the memory controller in the chipset is limited to 4GB, despite being seemingly identical to the memory controller in the same chipset newest MacBook model," then I'd just take their word for it. Has anyone tried it, or found any research as to whether two 4GB DDR3 1066mhz SO-DIMMs can be installed in the unibody MacBook without FireWire?

    Read the article

  • Split Tunnel VPN using incorrect Tunnel

    - by Brian Schmeltz
    Our company has a handful of field offices that have recently been setup with a regular internet connection after we removed the T1 and router that connected them directly to our network. Now, when the users are in the office, they log in to the VPN to be able to connect to the network. For the sake of them being able to print and scan from the local multi-function we have setup a split tunnel VPN. We currently have about 15-20 users using this setup around the country without any problems. Recently one of our users started having problems accessing internal programs/sites when connecting from both home and the office. There are three other users in the same office and they do not have this problem. I assumed that it was something with the computer and went ahead and replaced it with another of the same model. The computer worked fine in our home office; however, when the user received it, she had the exact same problem both at home and in the field office. Thinking it may be a NIC driver issue I sent her another computer, this time a different model, same problem occurred. If I update the host file to point to the correct paths, things will work, and if I connect via a normal VPN connection everything works, but the user cannot scan or print - which is a problem. Have tried to find ways to create another tunnel on a normal VPN and have tried to find ways to force the correct tunnel on the split tunnel VPN. It appears that there is something related to the ISP because if I connect to Comcast or Verizon it is fine but once she connects to Insite then she has problems. I have been unable to get any support from Insite as they don't feel the issue is with them. We use a Nortel VPN client. Any thoughts or ideas would be appreciated.

    Read the article

  • Split Tunnel VPN using incorrect Tunnel

    - by Brian Schmeltz
    Our company has a handful of field offices that have recently been setup with a regular internet connection after we removed the T1 and router that connected them directly to our network. Now, when the users are in the office, they log in to the VPN to be able to connect to the network. For the sake of them being able to print and scan from the local multi-function we have setup a split tunnel VPN. We currently have about 15-20 users using this setup around the country without any problems. Recently one of our users started having problems accessing internal programs/sites when connecting from both home and the office. There are three other users in the same office and they do not have this problem. I assumed that it was something with the computer and went ahead and replaced it with another of the same model. The computer worked fine in our home office; however, when the user received it, she had the exact same problem both at home and in the field office. Thinking it may be a NIC driver issue I sent her another computer, this time a different model, same problem occurred. If I update the host file to point to the correct paths, things will work, and if I connect via a normal VPN connection everything works, but the user cannot scan or print - which is a problem. Have tried to find ways to create another tunnel on a normal VPN and have tried to find ways to force the correct tunnel on the split tunnel VPN. It appears that there is something related to the ISP because if I connect to Comcast or Verizon it is fine but once she connects to Insite then she has problems. I have been unable to get any support from Insite as they don't feel the issue is with them. We use a Nortel VPN client. Any thoughts or ideas would be appreciated.

    Read the article

  • Gwibber on Ubuntu doesn't open

    - by Radian
    Gwibber Doesn't open . When I tried to Open it from Command Line I got this error ** (gwibber:3752): WARNING **: Trying to register gtype 'WnckWindowState' as enum when in fact it is of type 'GFlags' ** (gwibber:3752): WARNING **: Trying to register gtype 'WnckWindowActions' as enum when in fact it is of type 'GFlags' ** (gwibber:3752): WARNING **: Trying to register gtype 'WnckWindowMoveResizeMask' as enum when in fact it is of type 'GFlags' No dbus monitor yet Updating... ERROR:dbus.proxies:Introspect error on com.Gwibber.Service:/com/gwibber/Service: dbus.exceptions.DBusException: org.freedesktop.DBus.Error.NoReply: Message did not receive a reply (timeout by message bus) Traceback (most recent call last): File "/usr/bin/gwibber", line 67, in client.Client() File "/usr/lib/python2.6/dist-packages/gwibber/client.py", line 447, in init self.w = GwibberClient() File "/usr/lib/python2.6/dist-packages/gwibber/client.py", line 29, in init self.model = gwui.Model() File "/usr/lib/python2.6/dist-packages/gwibber/gwui.py", line 43, in init self.services = json.loads(self.daemon.GetServices()) File "/usr/lib/pymodules/python2.6/dbus/proxies.py", line 68, in call return self._proxy_method(*args, **keywords) File "/usr/lib/pymodules/python2.6/dbus/proxies.py", line 140, in call **keywords) File "/usr/lib/pymodules/python2.6/dbus/connection.py", line 620, in call_blocking message, timeout) dbus.exceptions.DBusException: org.freedesktop.DBus.Error.NoReply: Message did not receive a reply (timeout by message bus) I tried to remove it and to Install again but It has the same error It was Working probably , then suddenly it didn't

    Read the article

  • lm-sensors - always returns 32 degrees (celsius) for temperature

    - by mopoke
    On my VIA EPIA motherboard (using VIA VT8231 ISA bridge), I get strange output for the lm-sensors temperature reading. It always returns 32 degrees (celsius). I have previously had correct output for temperature (my munin graphs show temperatures typically in the range of 50 to 60 degrees. I've tried uninstalling (and purging) the lm-sensors package, have re-run sensors-detect a number of times and rebooted but nothing seems to change the output. I am running Ubuntu Karmic Koala (9.10). Anyone got any bright ideas on what I might have missed? uname -a: Linux george 2.6.31-16-386 #53-Ubuntu SMP Tue Dec 8 06:39:34 UTC 2009 i686 GNU/Linux cpuinfo: processor : 0 vendor_id : CentaurHauls cpu family : 6 model : 7 model name : VIA Samuel 2 stepping : 3 cpu MHz : 399.000 cache size : 64 KB fdiv_bug : no hlt_bug : no f00f_bug : no coma_bug : no fpu : yes fpu_exception : yes cpuid level : 1 wp : yes flags : fpu de tsc msr cx8 mtrr pge mmx 3dnow up bogomips : 800.04 clflush size : 32 power management: lspci: 00:00.0 Host bridge: VIA Technologies, Inc. VT8601 [Apollo ProMedia] (rev 05) 00:01.0 PCI bridge: VIA Technologies, Inc. VT8601 [Apollo ProMedia AGP] 00:11.0 ISA bridge: VIA Technologies, Inc. VT8231 [PCI-to-ISA Bridge] (rev 10) 00:11.1 IDE interface: VIA Technologies, Inc. VT82C586A/B/VT82C686/A/B/VT823x/A/C PIPC Bus Master IDE (rev 06) 00:11.2 USB Controller: VIA Technologies, Inc. VT82xxxxx UHCI USB 1.1 Controller (rev 1e) 00:11.3 USB Controller: VIA Technologies, Inc. VT82xxxxx UHCI USB 1.1 Controller (rev 1e) 00:11.4 Bridge: VIA Technologies, Inc. VT8235 ACPI (rev 10) 00:11.5 Multimedia audio controller: VIA Technologies, Inc. VT82C686 AC97 Audio Controller (rev 40) 00:12.0 Ethernet controller: VIA Technologies, Inc. VT6102 [Rhine-II] (rev 51) 01:00.0 VGA compatible controller: Trident Microsystems CyberBlade/i1 (rev 6a) sensors: acpitz-virtual-0 Adapter: Virtual device temp1: +32.0°C (crit = +60.0°C)

    Read the article

  • Windows Bluescreen - atikmpag.sys

    - by Mochan
    Information Name: atikmpag.sys bluescreen (BSOD or BlueScreen of Death) Error code: 0x00000116 Appears when: Playing games, watching videos Can be reproduced: Yes Cause: Graphics Card is the main assumption System Specifications Before we begin - I will inform you of my specifications. OS: Windows 7 x64 Home Edition Model: Dell Inspiron 15R Special Edition (aka Inspiron 7520) (Add 2GB of RAM to the model linked) Hard Drive: 1TB CPU: Intel Quad-Core i7 Sandy Bridge (I think) Processor at 2.10GHz (I think it can be clocked to 3GHz?) RAM: 6GB (I think 1 x 4GB and 1 x 2GB) Display: 15.6" HD (1366x768) Graphics: AMD Radeon HD 7500M 2GB Details So now that you know some basics about my computer, I'll get to the problem. Being an Ubuntu user I hardly use Windows, but occasionally I do. Like to run Skyrim and other games incompatible with Linux and WINE. The new Sims 3 Seasons patch is also now not supported. When playing these two games and other ones, theoretically. I have also heard others saying that while watching HD movies and video series it also happens. While watching the bluescreen as it happens, I see it is the 'atikmpag.sys' error. I have not installed much and nothing significant. I think I have downloaded Skyrim, Firefox and The Sims 3. I haven't done much more... since Ubuntu is definitely the best in comparison! (No hate, just a joke :P). I can reproduce it easily (just by running a game for less than a minute). It is always there each time, but it's never at a specific time or anything. So far I have found that it may be caused by lack of power to the graphics card, or it may be damaged or fried. Since I've had the computer for a mere 4 months (and have had other problems with it also). I have contacted Dell but they are useless beyond belief. Anyone with any information, solutions or details are encouraged to share your knowledge, as it would be immensely appreciated.

    Read the article

  • How can I run Gnome or KDE locally in Cygwin?

    - by John Peter Thompson Garcés
    Apparently it is possible to do this using cygwin ports, as can be seen in screenshots. I followed this how-to to get apt-cygports set up, and I used it to install gnome-session. This how-to supposedly gives the commands needed to run Gnome or KDE, but whenever I try to run Gnome, a blank X-window pops up and then quickly disappears. Here is the terminal output: $ startx /usr/bin/dbus-launch gnome-session xauth: file /home/jpthomps/.serverauth.4168 does not exist Welcome to the XWin X Server Vendor: The Cygwin/X Project Release: 1.10.3.0 OS: Windows 7 Service Pack 1 [Windows NT 6.1 build 7601] (WoW64) Package: version 1.10.3-12 built 2011-08-22 XWin was started with the following command line: /usr/bin/X :0 -auth /home/jpthomps/.serverauth.4168 (II) xorg.conf is not supported (II) See http://x.cygwin.com/docs/faq/cygwin-x-faq.html for more information LoadPreferences: /home/jpthomps/.XWinrc not found LoadPreferences: Loading /etc/X11/system.XWinrc LoadPreferences: Done parsing the configuration file... winDetectSupportedEngines - DirectDraw installed, allowing ShadowDD winDetectSupportedEngines - Windows NT, allowing PrimaryDD winDetectSupportedEngines - DirectDraw4 installed, allowing ShadowDDNL winDetectSupportedEngines - Returning, supported engines 0000001f winSetEngine - Using Shadow DirectDraw NonLocking winScreenInit - Using Windows display depth of 32 bits per pixel winFinishScreenInitFB - Masks: 00ff0000 0000ff00 000000ff Screen 0 added at virtual desktop coordinate (0,0). MIT-SHM extension disabled due to lack of kernel support XFree86-Bigfont extension local-client optimization disabled due to lack of shared memory support in the kernel (II) AIGLX: Loaded and initialized /usr/lib/dri/swrast_dri.so (II) GLX: Initialized DRISWRAST GL provider for screen 0 winPointerWarpCursor - Discarding first warp: 637 478 (--) 5 mouse buttons found (--) Setting autorepeat to delay=500, rate=31 (--) Windows keyboard layout: "00000409" (00000409) "US", type 4 (--) Found matching XKB configuration "English (USA)" (--) Model = "pc105" Layout = "us" Variant = "none" Options = "none" Rules = "base" Model = "pc105" Layout = "us" Variant = "none" Options = "none" winBlockHandler - pthread_mutex_unlock() winProcEstablishConnection - winInitClipboard returned. winClipboardProc - DISPLAY=:0.0 winClipboardProc - XOpenDisplay () returned and successfully opened the display. xinit: XFree86_VT property unexpectedly has 0 items instead of 1 xinit: connection to X server lost waiting for X server to shut down winClipboardProc - winClipboardFlushWindowsMessageQueue trapped WM_QUIT message, exiting main loop. winClipboardProc - XDestroyWindow succeeded. winClipboardProc - Clipboard disabled - Exit from server winDeinitMultiWindowWM - Noting shutdown in progress

    Read the article

  • 2008 Sever Randomly reboots.

    - by Jeff
    I'm out of ideas here. We have a 2008 Server that keeps rebooting 2-3 times a day at completely random times with an "Unexpected Shutdown" event. There are no Dumps, no events leading to it just like it loses power then comes back online. I ran a Diagnostic of the power supply and it has had continuous power for months. In addition, the temperature of the processors are maxing out at 40 degrees Celsius. Anyone have any ideas how to figure out why this is restarting all the time? This is a DMZed Web server so it doesn't do too much process wise. Here are the specs: Host Name: ~~~ OS Name: Microsoft Windows Server 2008 R2 Standard OS Version: 6.1.7600 N/A Build 7600 OS Manufacturer: Microsoft Corporation OS Configuration: Standalone Server OS Build Type: Multiprocessor Free Registered Owner: Windows User Registered Organization: Product ID: ~~~ Original Install Date: 5/27/2010, 4:25:47 PM System Boot Time: 2/14/2011, 5:35:01 PM System Manufacturer: HP System Model: ProLiant DL380 G6 System Type: x64-based PC Processor(s): 1 Processor(s) Installed. [01]: Intel64 Family 6 Model 26 Stepping 5 GenuineIntel ~1586 Mhz BIOS Version: HP P62, 8/16/2010 Windows Directory: C:\Windows System Directory: C:\Windows\system32 Boot Device: \Device\HarddiskVolume1 System Locale: en-us;English (United States) Input Locale: en-us;English (United States) Time Zone: (UTC-05:00) Eastern Time (US & Canada) Total Physical Memory: 4,086 MB Available Physical Memory: 2,775 MB Virtual Memory: Max Size: 8,170 MB Virtual Memory: Available: 6,691 MB Virtual Memory: In Use: 1,479 MB Page File Location(s): C:\pagefile.sys

    Read the article

  • Ubuntu lucid, maverick high iowait

    - by netom
    I'm using Ubuntu, and I've got the same problem with Lucid and Maverick. From time to time, especially a few minutes after boot, the iowait goes between 50-100% and the box is unusable. Everything that tries to access the disk freezes. I have the following setup: Hard disk: Model Family: Western Digital Caviar Green family Device Model: WDC WD15EADS-00P8B0 Serial Number: WD-WMAVU0391287 Firmware Version: 01.00A01 User Capacity: 1.500.301.910.016 bytes I have a quad core Intel Core2 Q6600 processor, and 4G of memory. When the high iowait occurs, usually 4 processes are active: kdmflush (two procs) jbd2/dm-0-8 jbd2/db-1-8 and a few more starving user processes of course. I know this from top and iotop. Any suggestions about why this is happening? There are a lot of q/a-s about linux and high iowait, but none of them helped so far, I even tweaked the hard disk not to park the head in every 8 seconds (Load cycle count is 50334!!!!! :o ), but nothing. Problem persists. Thank you in advance.

    Read the article

  • What are the most important aspects to consider when choosing a SAN for a small office virtualizatio

    - by Prof. Moriarty
    I am in the process of consolidating 6 physical servers running 6 different operating system flavors (don't ask) into two identical physical servers (Dell PowerEdge 2900), using the free VMware ESXi 4.0 platform. We will install an iSCSI SAN over a 1GbE network, and store all virtual machine images on the SAN. Each physical server would run 3 VMs, and in the case of a physical server failure, we would manually switch over the other 3. These are all internal servers, while important, they can tolerate some amount of downtime (say <1h) to keep cost and complexity associated with HA down. I now need to choose the SAN to be used for the setup, on a low budget. We currently have about 2TB of data, but of course I want to able to grow, do backups of VM snapshots on other drives and remove them to a different location, etc. So what I would like to know is: Which are the must have features for this setup, without which using a SAN is not worth it? We are mostly a Dell shop, so I have been looking at the EqualLogic PS4000E High Availability model. Any opinions, anecdotes, bad experiences with this model? (This is one of the few models which could accomodate our existing disks from the physical servers.) If you can recommend something that is not Dell, but it has better value, I would most definitely consider it. Caveats, things to look out for?

    Read the article

  • Xen domain migration locking problem

    - by brodie
    I am trying to live migrate a VM (domain) between two Xen servers. I have xen locking (xend-domain-lock = yes) configured with a ocfs2 shared storage between them. This locking is working fine. If I try to start up the VM on the secondary server it refuses to start (which is correct). The problem I am having is when trying to do live migration, it seems like it is trying to remove the lock twice. The first lock it removes is for "domain test", the second is for "migrating-test" which does not exist. Should their be a lock for this "migrating-test" VM? These are the relevant options in the xen config file: (xend-relocation-server yes) (xend-relocation-port 8002) (xend-relocation-address '') (xend-relocation-hosts-allow '') (xend-domain-lock yes) (xend-domain-lock-path /var/lib/xen/lock) This is the section of the log: [2010-06-10 10:45:57 14488] DEBUG (XendDomainInfo:4054) Releasing lock for domain test [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:474) SUSPEND shinfo 000c6ceb [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:474) delta 21ms, dom0 95%, target 0%, sent 57Mb/s, dirtied 173Mb/s 111 pages 4: sent 111, skipped 0, delta 6ms, dom0 100%, target 0%, sent 606Mb/s, dirtied 606Mb/s 111 pages [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:474) Total pages sent= 131295 (0.99x) [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:474) (of which 0 were fixups) [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:474) All memory is saved [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:474) Save exit rc=0 [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:123) Domain 22 suspended. [2010-06-10 10:45:57 14488] DEBUG (XendDomainInfo:2757) XendDomainInfo.destroy: domid=22 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2227) Destroying device model [2010-06-10 10:45:58 14488] INFO (image:567) migrating-test device model terminated [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2234) Releasing devices [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2247) Removing vif/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:1137) XendDomainInfo.destroyDevice: deviceClass = vif, device = vif/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2247) Removing vkbd/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:1137) XendDomainInfo.destroyDevice: deviceClass = vkbd, device = vkbd/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2247) Removing console/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:1137) XendDomainInfo.destroyDevice: deviceClass = console, device = console/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2247) Removing vbd/51712 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:1137) XendDomainInfo.destroyDevice: deviceClass = vbd, device = vbd/51712 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2247) Removing vfb/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:1137) XendDomainInfo.destroyDevice: deviceClass = vfb, device = vfb/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:4054) Releasing lock for domain migrating-test [2010-06-10 10:45:59 14488] ERROR (XendDomainInfo:4070) Failed to remove unmanaged directory /var/lib/xen/lock/b01515ae-9173-03cb-0cb7-06f3dfbede8b.

    Read the article

  • NIC are not advertising Correct Speeds

    - by Squidly
    I have an IBM x336 that is not advertising the proper LINK speeds. One interface is the other is not. I've tried to Force it to 1000/Full but then it just shows link down. I have confirmed the switch is set to auto negotiate like my switches. I have also changed out my Ethernet Cables. I'm at a loss where to look further. I have verified that it will connect at 1G on a different swtich. This also has happened on two different servers on the same switch. This is my output from mii-tool -v for each interface. eth0: negotiated 100baseTx-FD, link ok product info: vendor 00:08:18, model 24 rev 0 basic mode: autonegotiation enabled basic status: autonegotiation complete, link ok capabilities: 1000baseT-HD 1000baseT-FD 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD advertising: 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD flow-control link partner: 1000baseT-HD 1000baseT-FD 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD eth1: negotiated 1000baseT-FD flow-control, link ok product info: vendor 00:08:18, model 24 rev 0 basic mode: autonegotiation enabled basic status: autonegotiation complete, link ok capabilities: 1000baseT-HD 1000baseT-FD 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD advertising: 1000baseT-FD 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD flow-control link partner: 1000baseT-HD 1000baseT-FD 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD

    Read the article

  • PC won't PXE boot to WDS/MDT with Dell Optiplex 755

    - by Moman10
    I am trying to set up a basic MDT solution. I have set one up in the past at a previous job and it worked flawlessly, however here I'm running into a problem and am having no luck getting around it. I've installed Windows Server 2012 and MDT 2013, along with adding on the WDS role. I haven't configured much outside of the defaults for WDS, basically just set PXE response to respond to all clients (and unchecked admin approval). This machine does not run a DHCP server. I looked on the DHCP scope of our DHCP server, it shows options 66/67 checked and the server name of the WDS server is in there as well. I didn't add this but I assume it was put on during the install process (I believe I had to manually make some adjustments at my old job for this). The PC I have is a Dell Optiplex 755. I have enabled the onbard NIC w/PXE boot option in BIOS and attempted to boot. I get a "TFTP...." error but nothing offering out a DHCP address like I'm used to. In my previous job it pretty much worked right out of the box. I've verified that PortFast is enabled on the port and I've tried a couple different PCs (but both are the same model, only model I have to work with). No matter what, I get the same error. The subnet the PC is in is a different subnet than where the WDS server is sitting, but there are IP helper statements on the switch and the PCs can get regular DHCP addresses just fine from the DHCP server, just doesn't seem to get offered out a PXE boot option. I don't know if the problem is a configuration with the server or the PC itself...but after a few days of Googling I'm running out of ideas. Does anyone have a good idea of something it may be?

    Read the article

  • New build won't boot: some fans turning, no beep or video

    - by Dave
    When my new system is powered up, the case fan and power supply fans turn fine. The CPU fan twitches, but never gets going. Although I've heard that with AMDs and Gigabyte motherboards that is not necessary a problem. Hard drive is spinning. However, there is absolutely no indication that anything else is happening. The motherboard, as far as I can tell, does not have an internal speaker, but I harvested one from another machine and plugged it in and still no beeps at all. The monitor screen stays black, on both the integrated VGA and DVI. This is a brand new build, and has never successfully booted. My parts are: AMD Athlon II X2 245 Regor 2.9GHz Socket AM3 65W Dual-Core Processor Model ADX245OCGQBOX - includes CPU cooler) GIGABYTE GA-MA785GPMT-UD2H AM3 AMD 785G HDMI Micro ATX AMD Motherboard - Retail G.SKILL Ripjaws Series 4GB (2 x 2GB) 240-Pin DDR3 SDRAM DDR3 1333 (PC3 10666) Desktop Memory Model F3-10666CL8D-4GBRM - Retail CORSAIR CMPSU-400CX 400W ATX12V V2.2 80 PLUS Certified Compatible with Core i7 Power Supply - Retail SAMSUNG Spinpoint F3 HD502HJ 500GB 7200 RPM SATA 3.0Gb/s 3.5" Internal Hard Drive -Bare Drive COOLER MASTER Elite 341 RC-341C-KKN1-GP Black Steel MicroATX Mid Tower Computer Case - Retail I also have a DVD burner, but it acts the same whether that is plugged in or not. I'm using the on board video. What I've tried so far: I've switched power supplies, with no difference. I've tried different monitors (of which all are working on other machines) with no difference. I have tried putting it one memory module at a time, with no difference. I have tried the absolute minimum I can think of (power supply into motherboard, power button ONLY plugged into front panel, CPU fan plugged in), with no difference. I appreciate any ideas anyone might have. Do I need to RMA the motherboard? This is my first build, so there might be something obvious. I was very careful in assembly with static; I'm confident nothing was zapped during assembly.

    Read the article

  • Configuring ZenOSS to monitor CPU load

    - by Tom
    I'm trying test out monitoring tools for a network at work with a coworker but neither of us have ever used an sort of monitoring tools before. Currently we are experimenting with ZenOSS and having some difficulties. We want to populate our CPU load graphs because that is one of the primary feature we are looking for in our monitoring tools but we have been unable to populate the graphs with data. So far we have installed the wmipreformance, sqldatasource, wmidatasource, snmpperformance(simple) zenpacks and the machine we are trying to monitor is running Windows XP. We have tried to model the device and everything seems to run and we've tride to add data points to graphs but the only options we recieve for graphs are CPU and Memory. We are able to monitor services, ZenOSS recognizes the make and model of the processor, RAM, and Harddrive and is even giving us metrics on available storage but again, we are looking for performance metrics such as CPU load and Memory utilization. I realize I probably didn't provide a lot of information but that is because we don't have a very good idea of what we are doing and can't find instruction either on the ZenOSS homepage or forums to monitor CPU load. If someone could give us step by step instruction on how to set up CPU load monitoring that would probably be more beneficial to us than a diagnostic of our current setup, but regardless, if I left any important information out and you need it to answer the question, please let me know. Thank you.

    Read the article

  • Thecus N5200, disk has dropped out of RAID5

    - by Anders Ekdahl
    We have a Thecus 5200 NAS here at work with five WD Caviar Black 2TB disks in a RADI5 array. Yesterday, disk 4 dropped out of the array, and in the NAS web interface there's a warning about the RAID array being "degraded". When I go into Storage - Disks, disk 1 and 4 has a warning next to them. When I click on the warnings, this information about the disks are displayed: Tray Number 4 Model WD2001FASS-00W2B Power On Hours 2403 Hours Temperature Celsius 34 Reallocated Sector Count 66 Current Pending Sector 1447 Raw Read Error Rate 61 Seek Error Rate 0 Hardware ECC Recovered N/A Tray Number 1 Model WD2001FASS-00W2B Power On Hours 2403 Hours Temperature Celsius 32 Reallocated Sector Count 0 Current Pending Sector 1465 Raw Read Error Rate 0 Seek Error Rate 0 Hardware ECC Recovered N/A I'm not really an expert on either disks or RAID arrays. Does this indicate that the fourth disk is damaged, and needs to be replaced? And what about disk number one? It has a warning, but it's still in the array. Is it safe to add the fourth disk back into the array as a spare? I can't find any way to add it back as a it were before.

    Read the article

  • Asus K50I sound issues

    - by MrStatic
    I have an Asus K50IJ (Bestbuy) laptop and have issues with my sound. Speakers themselves work fine but when I plug into the headphone jack it auto mutes the front channel and no sounds comes out of either the speakers or the headphones. If I then unmute the channel I get sound from both the speakers and the headphones. alsamixer shows the Headphone channel as all grayed out. /etc/modprobe.d/alsa-base.conf I have tried snd-hda-intel model="asus-laptop" and snd-hda-intel model="asus" In Sound Preferences I have gone to output and changed the Connector to 'Analog Headphones' that results in no sound from either speakers or headphones. As one forum suggested I tried to comment out blacklist snd_pcsp in the blacklist.conf which resulted in no change. lspci -v shows: 00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) Subsystem: Santa Cruz Operation Device 1043 Flags: bus master, fast devsel, latency 0, IRQ 45 Memory at fe9f4000 (64-bit, non-prefetchable) [size=16K] Capabilities: [50] Power Management version 2 Capabilities: [60] MSI: Enable+ Count=1/1 Maskable- 64bit+ Capabilities: [70] Express Root Complex Integrated Endpoint, MSI 00 Capabilities: [100] Virtual Channel Capabilities: [130] Root Complex Link Kernel driver in use: HDA Intel Kernel modules: snd-hda-intel

    Read the article

  • VT-x not enabled on 2010 Mac Pro

    - by BlindingDawn
    To start I had a Hackintosh as per the instructions from Lifehacker.com before and moved everything to a new 2010 8 Core Mac Pro. I opted for a restore from the time machine backup rather than using the migration assistance. I believe this may have caused more problems but one in particular is the lack of VT-x support. When I checked Parallels Desktop under "Host Hardware" information, I get the following that shows that VT-x isn't enabled. <Cpu dyn_lists=""> <Number>16</Number> <Model>Intel(R) Xeon(R) CPU E5620 @ 2.40GHz</Model> <Mode>1</Mode> <Speed>2400</Speed> <VtxEnabled>0</VtxEnabled> <VtxMode>1</VtxMode> 1) Does Parallels Desktop support using VT-x? 2) Does this setting show that my VT-x isn't enabled? 3) Is there a way of fixing it so that it is enabled? 4) Is there a way of using my Time Machine backup as if I'm doing a restore using migration assistance and just restore the files and settings?

    Read the article