Search Results

Search found 21301 results on 853 pages for 'duplicate values'.

Page 235/853 | < Previous Page | 231 232 233 234 235 236 237 238 239 240 241 242  | Next Page >

  • Issuing Current Time Increments in StreamInsight (A Practical Example)

    The issuing of a Current Time Increment, Cti, in StreamInsight is very definitely one of the most important concepts to learn if you want your Streams to be responsive. A full discussion of how to issue Ctis is beyond the scope of this article but a very good explanation in addition to Books Online can be found in these three articles by a member of the StreamInsight team at Microsoft, Ciprian Gerea. Time in StreamInsight Series http://blogs.msdn.com/b/streaminsight/archive/2010/07/23/time-in-streaminsight-i.aspx http://blogs.msdn.com/b/streaminsight/archive/2010/07/30/time-in-streaminsight-ii.aspx http://blogs.msdn.com/b/streaminsight/archive/2010/08/03/time-in-streaminsight-iii.aspx A lot of the problems I see with unresponsive or stuck streams on the MSDN Forums are to do with how Ctis are enqueued or in a lot of cases not enqueued. If you enqueue events and never enqueue a Cti then StreamInsight will be perfectly happy. You, on the other hand, will never see data on the output as you have not told StreamInsight to flush the stream. This article deals with a specific implementation problem I had recently whilst working on a StreamInsight project. I look at some possible options and discuss why they would not work before showing the way I solved the problem. The stream of data I was dealing with on this project was very bursty that is to say when events were flowing they came through very quickly and in large numbers (1000 events/sec), but when the stream calmed down it could be a few seconds between each event. When enqueuing events into the StreamInsight engne it is best practice to do so with a StartTime that is given to you by the system producing the event . StreamInsight processes events and it doesn't matter whether those events are being pushed into the engine by a source system or the events are being read from something like a flat file in a directory somewhere. You can apply the same logic and temporal algebra to both situations. Reading from a file is an excellent example of where the time of the event on the source itself is very important. We could be reading that file a long time after it was written. Being able to read the StartTime from the events allows us to define windows that will hold the correct sets of events. I was able to do this with my stream but this is where my problems started. Below is a very simple script to create a SQL Server table and populate it with sample data that will show exactly the problem I had. CREATE TABLE [dbo].[t] ( [c1] [int] PRIMARY KEY, [c2] [datetime] NULL ) INSERT t VALUES (1,'20100810'),(2,'20100810'),(3,'20100810') Column c2 defines the StartTime of the event on the source and as you can see the values in all 3 rows of data is the same. If we read Ciprian’s articles we know that we can define how Ctis get injected into the stream in 3 different places The Stream Definition The Input Factory The Input Adapter I personally have always been a fan of enqueing Ctis through the factory. Below is code typical of what I would use to do this On the class itself I do some inheriting public class SimpleInputFactory : ITypedInputAdapterFactory<SimpleInputConfig>, ITypedDeclareAdvanceTimeProperties<SimpleInputConfig> And then I implement the following function public AdapterAdvanceTimeSettings DeclareAdvanceTimeProperties<TPayload>(SimpleInputConfig configInfo, EventShape eventShape) { return new AdapterAdvanceTimeSettings( new AdvanceTimeGenerationSettings(configInfo.CtiFrequency, TimeSpan.FromTicks(-1)), AdvanceTimePolicy.Adjust); } The configInfo .CtiFrequency property is a value I pass through to define after how many events I want a Cti to be injected and this in turn will flush through the stream of data. I usually pass a value of 1 for this setting. The second parameter determines the CTI timestamp in terms of a delay relative to the events. -1 ticks in the past results in 1 tick in the future, i.e., ahead of the event. The problem with this method though is that if consecutive events have the same StartTime then only one of those events will be enqueued. In this example I use the following to define how I assign the StartTime of my events currEvent.StartTime = (DateTimeOffset)dt.c2; If I go ahead and run my StreamInsight process with this configuration i can see on the output adapter that two events have been removed To see this in a little more depth I can use the StreamInsight Debugger and see what happens internally. What is happening here is that the first event arrives and a Cti is injected with a time of 1 tick after the StartTime of that event (Also the EndTime of the event). The second event arrives and it has a StartTime of before the Cti and even though we specified AdvanceTimePolicy.Adjust on the factory we know that a point event can never be adjusted like this and the event is dropped. The same happens for the third event as well (The second and third events get trumped by the Cti). For a more detailed discussion of why this happens look here http://www.sqlis.com/sqlis/post/AdvanceTimePolicy-and-Point-Event-Streams-In-StreamInsight.aspx We end up with a single event being pushed into the output adapter and our result now makes sense. The next way I tried to solve this problem by changing the value of the second parameter to TimeSpan.Zero Here is how my factory code now looks public AdapterAdvanceTimeSettings DeclareAdvanceTimeProperties<TPayload>(SimpleInputConfig configInfo, EventShape eventShape) { return new AdapterAdvanceTimeSettings( new AdvanceTimeGenerationSettings(configInfo.CtiFrequency, TimeSpan.Zero), AdvanceTimePolicy.Adjust); } What I am doing here is declaring a policy that says inject a Cti together with every event and stamp it with a StartTime that is equal to the start time of the event itself (TimeSpan.Zero). This method has plus points as well as a downside. The upside is that no events will be lost by having the same StartTime as previous events. The Downside is that because the Cti is declared with the StartTime of the event itself then it does not actually flush that particular event because in the StreamInsight algebra, a Cti commits only those events that occurred strictly before them. To flush the events we need a Cti to be enqueued with a greater StartTime than the events themselves. Here is what happened when I ran this configuration As you can see all we got through was the Cti and none of the events. The debugger output shows the stamps on the Cti and the events themselves. Because the Cti issued has the same timestamp (StartTime) as the events then none of the events get flushed. I was nearly there but not quite. Because my stream was bursty it was possible that the next event would not come along for a few seconds and this was far too long for an event to be enqueued and not be flushed to the output adapter. I needed another solution. Two possible solutions crossed my mind although only one of them made sense when I explored it some more. Where multiple events have the same StartTime I could add 1 tick to the first event, two to the second, three to third etc thereby giving them unique StartTime values. Add a timer to manually inject Ctis The problem with the first implementation is that I would be giving the events a new StartTime. This would cause me the following problems If I want to define windows over the stream then some events may not be captured in the right windows and therefore any calculations on those windows I did would be wrong What would happen if we had 10,000 events with the same StartTime? I would enqueue them with StartTime + n ticks. Along comes a genuine event with a StartTime of the very first event + 1 tick. It is now too far in the past as far as my stream is concerned and it would be dropped. Not what I would want to do at all. I decided then to look at the Timer based solution I created a timer on my input adapter that elapsed every 200ms. private Timer tmr; public SimpleInputAdapter(SimpleInputConfig configInfo) { ctx = new SimpleTimeExtractDataContext(configInfo.ConnectionString); this.configInfo = configInfo; tmr = new Timer(200); tmr.Elapsed += new ElapsedEventHandler(t_Elapsed); tmr.Enabled = true; } void t_Elapsed(object sender, ElapsedEventArgs e) { ts = DateTime.Now - dtCtiIssued; if (ts.TotalMilliseconds >= 200 && TimerIssuedCti == false) { EnqueueCtiEvent(System.DateTime.Now.AddTicks(-100)); TimerIssuedCti = true; } }   In the t_Elapsed event handler I find out the difference in time between now and when the last event was processed (dtCtiIssued). I then check to see if that is greater than or equal to 200ms and if the last issuing of a Cti was done by the timer or by a genuine event (TimerIssuedCti). If I didn’t do this check then I would enqueue a Cti every time the timer elapsed which is not something I wanted. If the difference between the two times is greater than or equal to 500ms and the last event enqueued was by a real event then I issue a Cti through the timer to flush the event Queue, otherwise I do nothing. When I enqueue the Ctis into my stream in my ProduceEvents method I also set the values of dtCtiIssued and TimerIssuedCti   currEvent = CreateInsertEvent(); currEvent.StartTime = (DateTimeOffset)dt.c2; TimerIssuedCti = false; dtCtiIssued = currEvent.StartTime; If I go ahead and run this configuration I see the following in my output. As we can see the first Cti gets enqueued as before but then another is enqueued by the timer and because this has a later timestamp it flushes the enqueued events through the engine. Conclusion Hopefully this has shown how the enqueuing of Ctis can have a dramatic effect on the responsiveness of your output in StreamInsight. Understanding the temporal nature of the product is for me one of the most important things you can learn. I have attached my solution for the demos. It is all in one project and testing each variation is a simple matter of commenting and un-commenting the parts in the code we have been dealing with here.

    Read the article

  • Disk is spinning down each minute, unable to disable it

    - by lzap
    I played with spindown and APM settings of my Samsung discs and now they spin down every minute. I want to disable it, but it seems it does not accept any of the spindown time or APM values. Nothing works, it's all the same. Please help what values should be proper for it. I do not want it to spin down at all. /dev/sda: ATA device, with non-removable media Model Number: SAMSUNG HD154UI Serial Number: S1Y6J1KZ206527 Firmware Revision: 1AG01118 Standards: Used: ATA-8-ACS revision 3b Supported: 7 6 5 4 Configuration: Logical max current cylinders 16383 16383 heads 16 16 sectors/track 63 63 -- CHS current addressable sectors: 16514064 LBA user addressable sectors: 268435455 LBA48 user addressable sectors: 2930277168 Logical/Physical Sector size: 512 bytes device size with M = 1024*1024: 1430799 MBytes device size with M = 1000*1000: 1500301 MBytes (1500 GB) cache/buffer size = unknown Capabilities: LBA, IORDY(can be disabled) Queue depth: 32 Standby timer values: spec'd by Standard, no device specific minimum R/W multiple sector transfer: Max = 16 Current = 16 Advanced power management level: 60 Recommended acoustic management value: 254, current value: 0 DMA: mdma0 mdma1 mdma2 udma0 udma1 udma2 udma3 udma4 udma5 *udma6 udma7 Cycle time: min=120ns recommended=120ns PIO: pio0 pio1 pio2 pio3 pio4 Cycle time: no flow control=120ns IORDY flow control=120ns Commands/features: Enabled Supported: * SMART feature set Security Mode feature set * Power Management feature set * Write cache * Look-ahead * Host Protected Area feature set * WRITE_BUFFER command * READ_BUFFER command * NOP cmd * DOWNLOAD_MICROCODE * Advanced Power Management feature set Power-Up In Standby feature set * SET_FEATURES required to spinup after power up SET_MAX security extension Automatic Acoustic Management feature set * 48-bit Address feature set * Device Configuration Overlay feature set * Mandatory FLUSH_CACHE * FLUSH_CACHE_EXT * SMART error logging * SMART self-test Media Card Pass-Through * General Purpose Logging feature set * 64-bit World wide name * WRITE_UNCORRECTABLE_EXT command * {READ,WRITE}_DMA_EXT_GPL commands * Segmented DOWNLOAD_MICROCODE * Gen1 signaling speed (1.5Gb/s) * Gen2 signaling speed (3.0Gb/s) * Native Command Queueing (NCQ) * Host-initiated interface power management * Phy event counters * NCQ priority information DMA Setup Auto-Activate optimization Device-initiated interface power management * Software settings preservation * SMART Command Transport (SCT) feature set * SCT Long Sector Access (AC1) * SCT LBA Segment Access (AC2) * SCT Error Recovery Control (AC3) * SCT Features Control (AC4) * SCT Data Tables (AC5) Security: Master password revision code = 65534 supported not enabled not locked frozen not expired: security count supported: enhanced erase 326min for SECURITY ERASE UNIT. 326min for ENHANCED SECURITY ERASE UNIT. Logical Unit WWN Device Identifier: 50024e900300cca3 NAA : 5 IEEE OUI : 0024e9 Unique ID : 00300cca3 Checksum: correct I have the very same disc which I did not "tuned" and it does not spin. But I do not know where to read the settings from. The hdparm only shows this: Advanced power management level: 60 Recommended acoustic management value: 254, current value: 0 Edit: It seems the issue was tuned daemon in RHEL6. It was too aggressive, I turned off disc tuning and it seems they are no longer spinning down.

    Read the article

  • SQL SERVER – Concurrency Basics – Guest Post by Vinod Kumar

    - by pinaldave
    This guest post is by Vinod Kumar. Vinod Kumar has worked with SQL Server extensively since joining the industry over a decade ago. Working on various versions from SQL Server 7.0, Oracle 7.3 and other database technologies – he now works with the Microsoft Technology Center (MTC) as a Technology Architect. Let us read the blog post in Vinod’s own voice. Learning is always fun when it comes to SQL Server and learning the basics again can be more fun. I did write about Transaction Logs and recovery over my blogs and the concept of simplifying the basics is a challenge. In the real world we always see checks and queues for a process – say railway reservation, banks, customer supports etc there is a process of line and queue to facilitate everyone. Shorter the queue higher is the efficiency of system (a.k.a higher is the concurrency). Every database does implement this using checks like locking, blocking mechanisms and they implement the standards in a way to facilitate higher concurrency. In this post, let us talk about the topic of Concurrency and what are the various aspects that one needs to know about concurrency inside SQL Server. Let us learn the concepts as one-liners: Concurrency can be defined as the ability of multiple processes to access or change shared data at the same time. The greater the number of concurrent user processes that can be active without interfering with each other, the greater the concurrency of the database system. Concurrency is reduced when a process that is changing data prevents other processes from reading that data or when a process that is reading data prevents other processes from changing that data. Concurrency is also affected when multiple processes are attempting to change the same data simultaneously. Two approaches to managing concurrent data access: Optimistic Concurrency Model Pessimistic Concurrency Model Concurrency Models Pessimistic Concurrency Default behavior: acquire locks to block access to data that another process is using. Assumes that enough data modification operations are in the system that any given read operation is likely affected by a data modification made by another user (assumes conflicts will occur). Avoids conflicts by acquiring a lock on data being read so no other processes can modify that data. Also acquires locks on data being modified so no other processes can access the data for either reading or modifying. Readers block writer, writers block readers and writers. Optimistic Concurrency Assumes that there are sufficiently few conflicting data modification operations in the system that any single transaction is unlikely to modify data that another transaction is modifying. Default behavior of optimistic concurrency is to use row versioning to allow data readers to see the state of the data before the modification occurs. Older versions of the data are saved so a process reading data can see the data as it was when the process started reading and not affected by any changes being made to that data. Processes modifying the data is unaffected by processes reading the data because the reader is accessing a saved version of the data rows. Readers do not block writers and writers do not block readers, but, writers can and will block writers. Transaction Processing A transaction is the basic unit of work in SQL Server. Transaction consists of SQL commands that read and update the database but the update is not considered final until a COMMIT command is issued (at least for an explicit transaction: marked with a BEGIN TRAN and the end is marked by a COMMIT TRAN or ROLLBACK TRAN). Transactions must exhibit all the ACID properties of a transaction. ACID Properties Transaction processing must guarantee the consistency and recoverability of SQL Server databases. Ensures all transactions are performed as a single unit of work regardless of hardware or system failure. A – Atomicity C – Consistency I – Isolation D- Durability Atomicity: Each transaction is treated as all or nothing – it either commits or aborts. Consistency: ensures that a transaction won’t allow the system to arrive at an incorrect logical state – the data must always be logically correct.  Consistency is honored even in the event of a system failure. Isolation: separates concurrent transactions from the updates of other incomplete transactions. SQL Server accomplishes isolation among transactions by locking data or creating row versions. Durability: After a transaction commits, the durability property ensures that the effects of the transaction persist even if a system failure occurs. If a system failure occurs while a transaction is in progress, the transaction is completely undone, leaving no partial effects on data. Transaction Dependencies In addition to supporting all four ACID properties, a transaction might exhibit few other behaviors (known as dependency problems or consistency problems). Lost Updates: Occur when two processes read the same data and both manipulate the data, changing its value and then both try to update the original data to the new value. The second process might overwrite the first update completely. Dirty Reads: Occurs when a process reads uncommitted data. If one process has changed data but not yet committed the change, another process reading the data will read it in an inconsistent state. Non-repeatable Reads: A read is non-repeatable if a process might get different values when reading the same data in two reads within the same transaction. This can happen when another process changes the data in between the reads that the first process is doing. Phantoms: Occurs when membership in a set changes. It occurs if two SELECT operations using the same predicate in the same transaction return a different number of rows. Isolation Levels SQL Server supports 5 isolation levels that control the behavior of read operations. Read Uncommitted All behaviors except for lost updates are possible. Implemented by allowing the read operations to not take any locks, and because of this, it won’t be blocked by conflicting locks acquired by other processes. The process can read data that another process has modified but not yet committed. When using the read uncommitted isolation level and scanning an entire table, SQL Server can decide to do an allocation order scan (in page-number order) instead of a logical order scan (following page pointers). If another process doing concurrent operations changes data and move rows to a new location in the table, the allocation order scan can end up reading the same row twice. Also can happen if you have read a row before it is updated and then an update moves the row to a higher page number than your scan encounters later. Performing an allocation order scan under Read Uncommitted can cause you to miss a row completely – can happen when a row on a high page number that hasn’t been read yet is updated and moved to a lower page number that has already been read. Read Committed Two varieties of read committed isolation: optimistic and pessimistic (default). Ensures that a read never reads data that another application hasn’t committed. If another transaction is updating data and has exclusive locks on data, your transaction will have to wait for the locks to be released. Your transaction must put share locks on data that are visited, which means that data might be unavailable for others to use. A share lock doesn’t prevent others from reading but prevents them from updating. Read committed (snapshot) ensures that an operation never reads uncommitted data, but not by forcing other processes to wait. SQL Server generates a version of the changed row with its previous committed values. Data being changed is still locked but other processes can see the previous versions of the data as it was before the update operation began. Repeatable Read This is a Pessimistic isolation level. Ensures that if a transaction revisits data or a query is reissued the data doesn’t change. That is, issuing the same query twice within a transaction cannot pickup any changes to data values made by another user’s transaction because no changes can be made by other transactions. However, this does allow phantom rows to appear. Preventing non-repeatable read is a desirable safeguard but cost is that all shared locks in a transaction must be held until the completion of the transaction. Snapshot Snapshot Isolation (SI) is an optimistic isolation level. Allows for processes to read older versions of committed data if the current version is locked. Difference between snapshot and read committed has to do with how old the older versions have to be. It’s possible to have two transactions executing simultaneously that give us a result that is not possible in any serial execution. Serializable This is the strongest of the pessimistic isolation level. Adds to repeatable read isolation level by ensuring that if a query is reissued rows were not added in the interim, i.e, phantoms do not appear. Preventing phantoms is another desirable safeguard, but cost of this extra safeguard is similar to that of repeatable read – all shared locks in a transaction must be held until the transaction completes. In addition serializable isolation level requires that you lock data that has been read but also data that doesn’t exist. Ex: if a SELECT returned no rows, you want it to return no. rows when the query is reissued. This is implemented in SQL Server by a special kind of lock called the key-range lock. Key-range locks require that there be an index on the column that defines the range of values. If there is no index on the column, serializable isolation requires a table lock. Gets its name from the fact that running multiple serializable transactions at the same time is equivalent of running them one at a time. Now that we understand the basics of what concurrency is, the subsequent blog posts will try to bring out the basics around locking, blocking, deadlocks because they are the fundamental blocks that make concurrency possible. Now if you are with me – let us continue learning for SQL Server Locking Basics. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Performance, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology Tagged: Concurrency

    Read the article

  • Additional options in MDL

    - by Jane Zhang
        The Metadata Loader(MDL) enables you to populate a new repository as well as transfer, update, or restore a backup of existing repository metadata. It consists of two utilities: metadata export and metadata import. The export utility extracts metadata objects from a repository and writes the information into a file. The import utility reads the metadata information from an exported file and inserts the metadata objects into a repository.      While the Design Client provides an intuitive UI that helps you perform the most commonly used export and import tasks, OMBPlus scripting enables you to specify some additional options, and manage a control file that allows you to perform more specialized export and import tasks. Is it possible to utilize these options in MDL from Design Client? This article will tell you how to achieve it.      A property file named mdl.properties is used to configure the additional options. It stores options in name/value pairs. This file can be created and placed under the directory <owb installation path>/owb/bin/admin/. Below we will introduce the options that can be specified in the mdl.properties file. 1. DEFAULTDIRECTORY     When we open a Metadata Export/Import dialog in Design Client, a default directory is provided for MDL file and log file. For MDL Export, the default directory is <owb installation path>/owb/bin/. As for MDL Import, the default directory is <owb installation path>/owb/mdl/. It may not be the one you would want to use as a default. You can specify the option DEFAULTDIRECTORY in the mdl.properties file to set your own default directory for MDL Export/Import, for example, DEFAULTDIRECOTRY=/tmp/     In this example, the default directory is set to /tmp/. Be sure the value ends with a file separator since it represents a directory. In Windows, the file separator is “\”. In linux, the file separator is “/”. 2. MDLTRACEFILE     Sometimes we would like to trace the whole process of MDL Export/Import, and get detailed information about operations to help developers or supports troubleshooting. To turn on MDL trace, set the option MDLTRACEFILE in the mdl.properties file. MDLTRACEFILE=/tmp/mdl.trc    The right side of the equals sign is to specify the name of the file for MDL trace information to be written. If no path is specified, the file will be placed under directory <owb installation path>/owb/bin/admin/. However, the trace file may be large if the MDL file contains a large number of metadata objects, so please use this option sparingly. 3. CONTROLFILE       We can use a control file to specify how objects are imported or exported. We can set an option called CONTROLFILE in the mdl.properties file, so the control file can also be utilized in Design Client, for example, CONTROLFILE=/tmp/mdl_control_file.ctl     The control file stores options in name/value pairs. When using control file, be sure the file exists, otherwise an exception java.lang.Exception: CNV0002-0031(ERROR): Cannot find specified file will be thrown out during MDL Export/Import.      Next we will introduce some options specified in control file. ZIPFILEFORMAT     By default, MDL exports objects into a zip format file. This zip file has an .mdl extension and contains two files. For example, you export the repository metadata into a file called projects.mdl. When you unzip this MDL file, you obtain two files. The file projects.mdx contains the repository objects. The file mdlcatalog.xml contains internal information about the MDL XML file. Another choice is to combine these two files into one unzip text format file when doing MDL exporting.    In OMBPlus command related to MDL, there is an option called FILE_FORMAT which is used to specify the file format for the exported file. Its acceptable values are ZIP or TEXT. When the value TEXT is selected, the exported file is in text format, for example, OMBEXPORT MDL_FILE '/tmp/options_file_format_test.mdl' FILE_FORMAT TEXT FROM PROJECT 'MY_PROJECT'    How to achieve this via Design Client when doing an MDL exporting? Here we have another option called ZIPFILEFORMAT which has the same function as the FILE_FORMAT. The difference is the acceptable values for ZIPFILEFORMAT are Y or N. When the value is set to N, the exported file is in text format, otherwise it is in zip file format. LOGMESSAGELEVEL     Whenever you export or import repository metadata, MDL writes diagnostic and statistical information to a log file. Their are 3 types of status messages: Informational, Warning and Error. By default, the log file includes all types of message. Sometimes, user may only care about one type of messages, for example, they would like only error messages written to the log file. In order to achieve this, we can set an option called LOGMESSAGELEVEL in control file. The acceptable values for LOGMESSAGELEVEL are ALL, WARNING and ERROR. ALL: If the option LOGMESSAGELEVEL is set to ALL, all types of messages (Informational, Warning and Error) will be written into the log file. WARNING: If the option LOGMESSAGELEVEL is set to WARNING, only warning messages will be written into log file. ERROR: If the option LOGMESSAGELEVEL is set to ERROR, only error messages will be written into log file. UPDATEPROJECTATTRIBUTES, UPDATEMODULEATTRIBUTES      These two options are used to decide whether updating the attributes of projects/modules. The options work when projects/modules being imported already exist in repository and we use update metadata mode or replace metadata mode to do the MDL import. The acceptable values for these two options are Y or N. If the value is set to Y, the attributes of projects/modules will be updated, otherwise not.      Next, let’s give an example to see how these options take effect in MDL. 1. First of all, create the property file mdl.properties under the directory <owb installation path>/owb/bin/admin/. 2. Specify the options in the mdl.properties file, see the following screenshot. 3. Create the control file mdl_control_file.ctl under the directory /tmp/. Set the following options in control file. 4. Log into the OWB Design Client. 5. Create an Oracle module named ORA_MOD_1 under the project MY_PROJECT, then export the project MY_PROJECT into file my_project.mdl. 6. Check the trace file mdl.trc under the directory /tmp/. In this file, we can see very detail information for the above export task. 7. Check the exported MDL file. The file my_project.mdl is in text format. Opening the file, you can see the content of the file directly. It concats the file my_project.mdx and mdlcatalog.xml. 8. Modify the project MY_PROJECT and Oracle module ORA_MOD_1, add descriptions for them separately. Delete the location created in step 5. 9. Import the MDL file my_project.mdl. From the Metadata Import dialog, we can see the default directory for MDL file and log file has been changed to /tmp/. Here we use update metadata mode, match by names to do the importing. 10. After importing, check the description of the project MY_PROJECT, we can see the description is still there. But the description of the Oracle module ORA_MOD_1 has gone. That because we set the option UPDATEPROJECTATTRIBUTES to N, and set the option UPDATEMODULEATTRIBUTES to Y. 11. Check the log file, the log file only contains warning messages and the log message level is set to WARNING.      For more details about the 3 types of status messages, see Oracle® Warehouse Builder Installation and Administration Guide11g Release 2.

    Read the article

  • How to find the average color of an image.

    - by Edward Boyle
    Years ago I was the lead developer of a large Scrapbook Web Site. One of the things I implemented was to allow shoppers to find Scrapbook papers and embellishments of like colors (“more like this color”). Below is the base algorithm I wrote to extract the color from an image. It worked out pretty well. I took the returned values and stored them in an associated table for the products. Yet another algorithm was used to SELECT near matches. This algorithm has turned out to be very handy for me. I have used it for borders and subtle outlined text overlays. I am sure you will find more creative uses for it. Enjoy… private Color GetColor(Bitmap bmp) { int r = 0; int g = 0; int b = 0; Color mColor = System.Drawing.Color.White; for (int i = 1; i < bmp.Width; i++) { for (int x = 1; x < bmp.Height; x++) { mColor = bmp.GetPixel(i, x); r += mColor.R; g += mColor.G; b += mColor.B; } } r = (r / (bmp.Height * bmp.Width)); g = (g / (bmp.Height * bmp.Width)); b = (b / (bmp.Height * bmp.Width)); return System.Drawing.Color.FromArgb(r, g, b); } You could also get the RGB values by passing in the RGB by ref private Color GetColor(ref int r, ref int g, ref int b, Bitmap bmp) but that is a bit much as you can simply get it from the return value: mReturnedColor.R; mReturnedColor.G; mReturnedColor.B;

    Read the article

  • SQL Spatial: Getting “nearest” calculations working properly

    - by Rob Farley
    If you’ve ever done spatial work with SQL Server, I hope you’ve come across the ‘nearest’ problem. You have five thousand stores around the world, and you want to identify the one that’s closest to a particular place. Maybe you want the store closest to the LobsterPot office in Adelaide, at -34.925806, 138.605073. Or our new US office, at 42.524929, -87.858244. Or maybe both! You know how to do this. You don’t want to use an aggregate MIN or MAX, because you want the whole row, telling you which store it is. You want to use TOP, and if you want to find the closest store for multiple locations, you use APPLY. Let’s do this (but I’m going to use addresses in AdventureWorks2012, as I don’t have a list of stores). Oh, and before I do, let’s make sure we have a spatial index in place. I’m going to use the default options. CREATE SPATIAL INDEX spin_Address ON Person.Address(SpatialLocation); And my actual query: WITH MyLocations AS (SELECT * FROM (VALUES ('LobsterPot Adelaide', geography::Point(-34.925806, 138.605073, 4326)),                        ('LobsterPot USA', geography::Point(42.524929, -87.858244, 4326))                ) t (Name, Geo)) SELECT l.Name, a.AddressLine1, a.City, s.Name AS [State], c.Name AS Country FROM MyLocations AS l CROSS APPLY (     SELECT TOP (1) *     FROM Person.Address AS ad     ORDER BY l.Geo.STDistance(ad.SpatialLocation)     ) AS a JOIN Person.StateProvince AS s     ON s.StateProvinceID = a.StateProvinceID JOIN Person.CountryRegion AS c     ON c.CountryRegionCode = s.CountryRegionCode ; Great! This is definitely working. I know both those City locations, even if the AddressLine1s don’t quite ring a bell. I’m sure I’ll be able to find them next time I’m in the area. But of course what I’m concerned about from a querying perspective is what’s happened behind the scenes – the execution plan. This isn’t pretty. It’s not using my index. It’s sucking every row out of the Address table TWICE (which sucks), and then it’s sorting them by the distance to find the smallest one. It’s not pretty, and it takes a while. Mind you, I do like the fact that it saw an indexed view it could use for the State and Country details – that’s pretty neat. But yeah – users of my nifty website aren’t going to like how long that query takes. The frustrating thing is that I know that I can use the index to find locations that are within a particular distance of my locations quite easily, and Microsoft recommends this for solving the ‘nearest’ problem, as described at http://msdn.microsoft.com/en-au/library/ff929109.aspx. Now, in the first example on this page, it says that the query there will use the spatial index. But when I run it on my machine, it does nothing of the sort. I’m not particularly impressed. But what we see here is that parallelism has kicked in. In my scenario, it’s split the data up into 4 threads, but it’s still slow, and not using my index. It’s disappointing. But I can persuade it with hints! If I tell it to FORCESEEK, or use my index, or even turn off the parallelism with MAXDOP 1, then I get the index being used, and it’s a thing of beauty! Part of the plan is here: It’s massive, and it’s ugly, and it uses a TVF… but it’s quick. The way it works is to hook into the GeodeticTessellation function, which is essentially finds where the point is, and works out through the spatial index cells that surround it. This then provides a framework to be able to see into the spatial index for the items we want. You can read more about it at http://msdn.microsoft.com/en-us/library/bb895265.aspx#tessellation – including a bunch of pretty diagrams. One of those times when we have a much more complex-looking plan, but just because of the good that’s going on. This tessellation stuff was introduced in SQL Server 2012. But my query isn’t using it. When I try to use the FORCESEEK hint on the Person.Address table, I get the friendly error: Msg 8622, Level 16, State 1, Line 1 Query processor could not produce a query plan because of the hints defined in this query. Resubmit the query without specifying any hints and without using SET FORCEPLAN. And I’m almost tempted to just give up and move back to the old method of checking increasingly large circles around my location. After all, I can even leverage multiple OUTER APPLY clauses just like I did in my recent Lookup post. WITH MyLocations AS (SELECT * FROM (VALUES ('LobsterPot Adelaide', geography::Point(-34.925806, 138.605073, 4326)),                        ('LobsterPot USA', geography::Point(42.524929, -87.858244, 4326))                ) t (Name, Geo)) SELECT     l.Name,     COALESCE(a1.AddressLine1,a2.AddressLine1,a3.AddressLine1),     COALESCE(a1.City,a2.City,a3.City),     s.Name AS [State],     c.Name AS Country FROM MyLocations AS l OUTER APPLY (     SELECT TOP (1) *     FROM Person.Address AS ad     WHERE l.Geo.STDistance(ad.SpatialLocation) < 1000     ORDER BY l.Geo.STDistance(ad.SpatialLocation)     ) AS a1 OUTER APPLY (     SELECT TOP (1) *     FROM Person.Address AS ad     WHERE l.Geo.STDistance(ad.SpatialLocation) < 5000     AND a1.AddressID IS NULL     ORDER BY l.Geo.STDistance(ad.SpatialLocation)     ) AS a2 OUTER APPLY (     SELECT TOP (1) *     FROM Person.Address AS ad     WHERE l.Geo.STDistance(ad.SpatialLocation) < 20000     AND a2.AddressID IS NULL     ORDER BY l.Geo.STDistance(ad.SpatialLocation)     ) AS a3 JOIN Person.StateProvince AS s     ON s.StateProvinceID = COALESCE(a1.StateProvinceID,a2.StateProvinceID,a3.StateProvinceID) JOIN Person.CountryRegion AS c     ON c.CountryRegionCode = s.CountryRegionCode ; But this isn’t friendly-looking at all, and I’d use the method recommended by Isaac Kunen, who uses a table of numbers for the expanding circles. It feels old-school though, when I’m dealing with SQL 2012 (and later) versions. So why isn’t my query doing what it’s supposed to? Remember the query... WITH MyLocations AS (SELECT * FROM (VALUES ('LobsterPot Adelaide', geography::Point(-34.925806, 138.605073, 4326)),                        ('LobsterPot USA', geography::Point(42.524929, -87.858244, 4326))                ) t (Name, Geo)) SELECT l.Name, a.AddressLine1, a.City, s.Name AS [State], c.Name AS Country FROM MyLocations AS l CROSS APPLY (     SELECT TOP (1) *     FROM Person.Address AS ad     ORDER BY l.Geo.STDistance(ad.SpatialLocation)     ) AS a JOIN Person.StateProvince AS s     ON s.StateProvinceID = a.StateProvinceID JOIN Person.CountryRegion AS c     ON c.CountryRegionCode = s.CountryRegionCode ; Well, I just wasn’t reading http://msdn.microsoft.com/en-us/library/ff929109.aspx properly. The following requirements must be met for a Nearest Neighbor query to use a spatial index: A spatial index must be present on one of the spatial columns and the STDistance() method must use that column in the WHERE and ORDER BY clauses. The TOP clause cannot contain a PERCENT statement. The WHERE clause must contain a STDistance() method. If there are multiple predicates in the WHERE clause then the predicate containing STDistance() method must be connected by an AND conjunction to the other predicates. The STDistance() method cannot be in an optional part of the WHERE clause. The first expression in the ORDER BY clause must use the STDistance() method. Sort order for the first STDistance() expression in the ORDER BY clause must be ASC. All the rows for which STDistance returns NULL must be filtered out. Let’s start from the top. 1. Needs a spatial index on one of the columns that’s in the STDistance call. Yup, got the index. 2. No ‘PERCENT’. Yeah, I don’t have that. 3. The WHERE clause needs to use STDistance(). Ok, but I’m not filtering, so that should be fine. 4. Yeah, I don’t have multiple predicates. 5. The first expression in the ORDER BY is my distance, that’s fine. 6. Sort order is ASC, because otherwise we’d be starting with the ones that are furthest away, and that’s tricky. 7. All the rows for which STDistance returns NULL must be filtered out. But I don’t have any NULL values, so that shouldn’t affect me either. ...but something’s wrong. I do actually need to satisfy #3. And I do need to make sure #7 is being handled properly, because there are some situations (eg, differing SRIDs) where STDistance can return NULL. It says so at http://msdn.microsoft.com/en-us/library/bb933808.aspx – “STDistance() always returns null if the spatial reference IDs (SRIDs) of the geography instances do not match.” So if I simply make sure that I’m filtering out the rows that return NULL… …then it’s blindingly fast, I get the right results, and I’ve got the complex-but-brilliant plan that I wanted. It just wasn’t overly intuitive, despite being documented. @rob_farley

    Read the article

  • Auto-cancel reason not found (6, 13906)

    - by Rajesh Sharma
    There are many errors in the application which are never invoked because of appropriate application configuration done at the time of implementation by the solution architects. So typically, as an application end user you would never stumble upon such errors. But what if the application administrator inadvertently changes the configuration/setup in the development, test, QA, or production environment? This is the time when you as an end user are introduced to a brand-new error for which you may not have a clue or understanding to what it means and neither the access/privilege to rectify it.    In this post we'll focus on one such error '6, 13906 - Auto-cancel reason not found'.   You get this error if you have not defined a Bill (Segment) Cancel Reason (Admin Menu, B, Bill Cancel Reason) code with System Default value of Turn off auto-cancel.   Consider a scenario when you are about to final bill an 'Account' for which the bill period's cut-off date you selected is falling on or after the Service Agreement's (SA) end/stop date (basically SA is Stopped with a date earlier than it was billed previously). And for the same 'Account' either: Bill segments exists that end after the SA's end date OR Non-closing bill segments exists that end on the SA's end date (OR closing bill segments that do not end on SA's end date or do not exist at all - remember closing/final bill segment is generated if the SA is in Stopped status).   CC&B detects such scenario and attempts to cancel all such violating bill segments automatically, but NOT if you are generating the bill Online. If online, the system assumes that you know what you are doing, and prompts you with error 2, 13716 - Bill segments that violate the SA (%1) End Date (%2) exist to take necessary action.   If in batch, system automatically cancels these kinds of bill segment(s).   Since this happens in the background, you have to define within the application which System Default Bill (Segment) cancellation reason code identified as Turn off auto-cancel, should be used by the process when it attempts to cancel any such violating bill segments (You already know that you cannot cancel a bill segment without giving a reason for cancellation).   So what exactly happens during batch billing?   Bill Segment generation routine at first determines billing eligibility of the service agreement being billed. One of the billing eligibility criteria is to check the SA's previous bill segments which have end dates greater than the current cut-off date/end date. Technically, the routine retrieves a count of such violating bill segments.     SELECT COUNT (*) FROM CI_BSEG WHERE SA_ID = :SA-ID AND BSEG_STAT_FLG = '50' -- Frozen AND END_DT IS NOT NULL AND (END_DT > '03-JUN-2010' -- Bill segment greater than SA's End Date OR OR (END_DT = '03-JUN-2010' AND CLOSING_BSEG_SW = 'N')) -- Non-closing bill segment ending on SA's end date   If the count is greater than zero, Bill segment generation routine executes another program to auto-cancel such bill segments. Auto-cancel program retrieves the 'Bill Cancel Reason' code which is identified as Turn off auto-cancel. Retrieved cancel reason code is then placed on the bill segments that are being cancelled automatically.   During this process if the routine fails to determine the bill cancel reason code having System Default Turn off auto-cancel because it was not been configured, you get a bill exception 6, 13906 - Auto-cancel reason not found.   Also note that duplicate or multiple System Default codes identified as Turn off auto-cancel are not allowed. CC&B would complain with an error 2, 54201.   Duplicate validation/check is also performed within Auto-cancel routine, if suppose for test purposes you executed a DML statement updating CI_BILL_CAN_RSN.BSCAN_SYS_DFLT_FLG with a value 'T'.

    Read the article

  • SQL SERVER – Introduction to PERCENTILE_CONT() – Analytic Functions Introduced in SQL Server 2012

    - by pinaldave
    SQL Server 2012 introduces new analytical function PERCENTILE_CONT(). The book online gives following definition of this function: Computes a specific percentile for sorted values in an entire rowset or within distinct partitions of a rowset in Microsoft SQL Server 2012 Release Candidate 0 (RC 0). For a given percentile value P, PERCENTILE_DISC sorts the values of the expression in the ORDER BY clause and returns the value with the smallest CUME_DIST value (with respect to the same sort specification) that is greater than or equal to P. If you are clear with understanding of the function – no need to read further. If you got lost here is the same in simple words – it is lot like finding median with percentile value. Now let’s have fun following query: USE AdventureWorks GO SELECT SalesOrderID, OrderQty, ProductID, PERCENTILE_CONT(0.5) WITHIN GROUP (ORDER BY ProductID) OVER (PARTITION BY SalesOrderID) AS MedianCont FROM Sales.SalesOrderDetail WHERE SalesOrderID IN (43670, 43669, 43667, 43663) ORDER BY SalesOrderID DESC GO The above query will give us the following result: You can see that I have used PERCENTILE_COUNT(0.5) in query, which is similar to finding median. Let me explain above diagram with little more explanation. The defination of median is as following: In case of Even Number of elements = In ordered list add the two digits from the middle and devide by 2 In case of Odd Numbers of elements = In ordered list select the digits from the middle I hope this example gives clear idea how PERCENTILE_CONT() works. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, SQL, SQL Authority, SQL Function, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • How to enable CDR on AsteriskNow 1.5

    - by Michal Niklas
    I have upgraded PBX to Asterisk 1.6.2.7 and now CDR files are not created. It looks that such logging is disabled: Connected to Asterisk 1.6.2.7 currently running on pbx2 (pid = 5824) Verbosity is at least 3 pbx2*CLI> cdr show status pbx2*CLI> Call Detail Record (CDR) settings ---------------------------------- Logging: Disabled Mode: Simple Asterisk shows that CDR modules are loaded: pbx2*CLI> module show like cd Module Description Use Count cdr_manager.so Asterisk Manager Interface CDR Backend 0 cdr_csv.so Comma Separated Values CDR Backend 0 app_cdr.so Tell Asterisk to not maintain a CDR for 0 app_forkcdr.so Fork The CDR into 2 separate entities 0 func_cdr.so Call Detail Record (CDR) dialplan functi 0 cdr_custom.so Customizable Comma Separated Values CDR 0 6 modules loaded How to enable creating CDR csv files?

    Read the article

  • After restoring a SQL Server database from another server - get login fails

    - by Renso
    Issue: After you have restored a sql server database from another server, lets say from production to a Q/A environment, you get the "Login Fails" message for your service account. Reason: User logon information is stored in the syslogins table in the master database. By changing servers, or by altering this information by rebuilding or restoring an old version of the master database, the information may be different from when the user database dump was created. If logons do not exist for the users, they will receive an error indicating "Login failed" while attempting to log on to the server. If the user logons do exist, but the SUID values (for 6.x) or SID values (for 7.0) in master..syslogins and the sysusers table in the user database differ, the users may have different permissions than expected in the user database. Solution: Links a user entry in the sys.database_principals system catalog view in the current database to a SQL Server login of the same name. If a login with the same name does not exist, one will be created. Examine the result from the Auto_Fix statement to confirm that the correct link is in fact made. Avoid using Auto_Fix in security-sensitive situations. When you use Auto_Fix, you must specify user and password if the login does not already exist, otherwise you must specify user but password will be ignored. login must be NULL. user must be a valid user in the current database. The login cannot have another user mapped to it. execute the following stored procedure, in this example the login user name is "MyUser" exec sp_change_users_login 'Auto_Fix', 'MyUser'   NOTE: sp_change_users_login cannot be used with a SQL Server login created from a Windows principal or with a user created by using CREATE USER WITHOUT LOGIN.

    Read the article

  • Passing multiple Vertex Attributes in GLSL 130

    - by Roy T.
    (note this question is closely related to this one however I didn't fully understand the accepted answer) To support videocards in laptops I have to rewrite my GLSL 330 shaders to GLSL 130. I'm trying to do this but somehow I don't get vertex attributes to work properly. My 330 shaders look like this: #version 330 layout(location = 0) in vec4 position; layout(location = 3) in vec4 color; smooth out vec4 theColor; void main() { gl_Position = position; theColor = color; } Now this explicit layout is not allowed in GLSL 130 so I referenced this page to see what the default layouts for some values would be. As you can see position should be the 0th vertex attribute and color should be the 3rd vertex attribute. Because this is a test case I had already configured my explicit layouts in the same way, which worked, so I now simply rewrote my shader to this and expected it to work: #version 130 smooth out vec4 theColor; void main() { gl_Position = gl_Vertex; theColor = gl_Color; } However this doesn't work, the value of gl_Color is always (1,1,1,1). So how should I pass multiple vertex attributes to my GLSL 130 shaders? For reference, this is how I set my vertex buffer object and attributes (I've just adapted this tutorial to JAVA+JOGL) gl.glBindBuffer(GL3.GL_ARRAY_BUFFER, vertex_buffer_id); gl.glEnableVertexAttribArray(0); gl.glEnableVertexAttribArray(3); gl.glVertexAttribPointer(0, 4 , GL3.GL_FLOAT, false, 0, 0); gl.glVertexAttribPointer(3, 4, GL3.GL_FLOAT, false, 0, 4*4*4); gl.glDrawArrays(GL3.GL_TRIANGLE_STRIP, 0, 4); gl.glDisableVertexAttribArray(0); gl.glDisableVertexAttribArray(3); EDIT I solved the problem by querying for the layout locations of position an color using glGetAttribLocation however I still don't understand why the 'hardcoded' values like gl_Color didn't work, can't I upload data in there as normal? Shouldn't they be used?

    Read the article

  • Performance Optimization &ndash; It Is Faster When You Can Measure It

    - by Alois Kraus
    Performance optimization in bigger systems is hard because the measured numbers can vary greatly depending on the measurement method of your choice. To measure execution timing of specific methods in your application you usually use Time Measurement Method Potential Pitfalls Stopwatch Most accurate method on recent processors. Internally it uses the RDTSC instruction. Since the counter is processor specific you can get greatly different values when your thread is scheduled to another core or the core goes into a power saving mode. But things do change luckily: Intel's Designer's vol3b, section 16.11.1 "16.11.1 Invariant TSC The time stamp counter in newer processors may support an enhancement, referred to as invariant TSC. Processor's support for invariant TSC is indicated by CPUID.80000007H:EDX[8]. The invariant TSC will run at a constant rate in all ACPI P-, C-. and T-states. This is the architectural behavior moving forward. On processors with invariant TSC support, the OS may use the TSC for wall clock timer services (instead of ACPI or HPET timers). TSC reads are much more efficient and do not incur the overhead associated with a ring transition or access to a platform resource." DateTime.Now Good but it has only a resolution of 16ms which can be not enough if you want more accuracy.   Reporting Method Potential Pitfalls Console.WriteLine Ok if not called too often. Debug.Print Are you really measuring performance with Debug Builds? Shame on you. Trace.WriteLine Better but you need to plug in some good output listener like a trace file. But be aware that the first time you call this method it will read your app.config and deserialize your system.diagnostics section which does also take time.   In general it is a good idea to use some tracing library which does measure the timing for you and you only need to decorate some methods with tracing so you can later verify if something has changed for the better or worse. In my previous article I did compare measuring performance with quantum mechanics. This analogy does work surprising well. When you measure a quantum system there is a lower limit how accurately you can measure something. The Heisenberg uncertainty relation does tell us that you cannot measure of a quantum system the impulse and location of a particle at the same time with infinite accuracy. For programmers the two variables are execution time and memory allocations. If you try to measure the timings of all methods in your application you will need to store them somewhere. The fastest storage space besides the CPU cache is the memory. But if your timing values do consume all available memory there is no memory left for the actual application to run. On the other hand if you try to record all memory allocations of your application you will also need to store the data somewhere. This will cost you memory and execution time. These constraints are always there and regardless how good the marketing of tool vendors for performance and memory profilers are: Any measurement will disturb the system in a non predictable way. Commercial tool vendors will tell you they do calculate this overhead and subtract it from the measured values to give you the most accurate values but in reality it is not entirely true. After falling into the trap to trust the profiler timings several times I have got into the habit to Measure with a profiler to get an idea where potential bottlenecks are. Measure again with tracing only the specific methods to check if this method is really worth optimizing. Optimize it Measure again. Be surprised that your optimization has made things worse. Think harder Implement something that really works. Measure again Finished! - Or look for the next bottleneck. Recently I have looked into issues with serialization performance. For serialization DataContractSerializer was used and I was not sure if XML is really the most optimal wire format. After looking around I have found protobuf-net which uses Googles Protocol Buffer format which is a compact binary serialization format. What is good for Google should be good for us. A small sample app to check out performance was a matter of minutes: using ProtoBuf; using System; using System.Diagnostics; using System.IO; using System.Reflection; using System.Runtime.Serialization; [DataContract, Serializable] class Data { [DataMember(Order=1)] public int IntValue { get; set; } [DataMember(Order = 2)] public string StringValue { get; set; } [DataMember(Order = 3)] public bool IsActivated { get; set; } [DataMember(Order = 4)] public BindingFlags Flags { get; set; } } class Program { static MemoryStream _Stream = new MemoryStream(); static MemoryStream Stream { get { _Stream.Position = 0; _Stream.SetLength(0); return _Stream; } } static void Main(string[] args) { DataContractSerializer ser = new DataContractSerializer(typeof(Data)); Data data = new Data { IntValue = 100, IsActivated = true, StringValue = "Hi this is a small string value to check if serialization does work as expected" }; var sw = Stopwatch.StartNew(); int Runs = 1000 * 1000; for (int i = 0; i < Runs; i++) { //ser.WriteObject(Stream, data); Serializer.Serialize<Data>(Stream, data); } sw.Stop(); Console.WriteLine("Did take {0:N0}ms for {1:N0} objects", sw.Elapsed.TotalMilliseconds, Runs); Console.ReadLine(); } } The results are indeed promising: Serializer Time in ms N objects protobuf-net   807 1000000 DataContract 4402 1000000 Nearly a factor 5 faster and a much more compact wire format. Lets use it! After switching over to protbuf-net the transfered wire data has dropped by a factor two (good) and the performance has worsened by nearly a factor two. How is that possible? We have measured it? Protobuf-net is much faster! As it turns out protobuf-net is faster but it has a cost: For the first time a type is de/serialized it does use some very smart code-gen which does not come for free. Lets try to measure this one by setting of our performance test app the Runs value not to one million but to 1. Serializer Time in ms N objects protobuf-net 85 1 DataContract 24 1 The code-gen overhead is significant and can take up to 200ms for more complex types. The break even point where the code-gen cost is amortized by its faster serialization performance is (assuming small objects) somewhere between 20.000-40.000 serialized objects. As it turned out my specific scenario involved about 100 types and 1000 serializations in total. That explains why the good old DataContractSerializer is not so easy to take out of business. The final approach I ended up was to reduce the number of types and to serialize primitive types via BinaryWriter directly which turned out to be a pretty good alternative. It sounded good until I measured again and found that my optimizations so far do not help much. After looking more deeper at the profiling data I did found that one of the 1000 calls did take 50% of the time. So how do I find out which call it was? Normal profilers do fail short at this discipline. A (totally undeserved) relatively unknown profiler is SpeedTrace which does unlike normal profilers create traces of your applications by instrumenting your IL code at runtime. This way you can look at the full call stack of the one slow serializer call to find out if this stack was something special. Unfortunately the call stack showed nothing special. But luckily I have my own tracing as well and I could see that the slow serializer call did happen during the serialization of a bool value. When you encounter after much analysis something unreasonable you cannot explain it then the chances are good that your thread was suspended by the garbage collector. If there is a problem with excessive GCs remains to be investigated but so far the serialization performance seems to be mostly ok.  When you do profile a complex system with many interconnected processes you can never be sure that the timings you just did measure are accurate at all. Some process might be hitting the disc slowing things down for all other processes for some seconds as well. There is a big difference between warm and cold startup. If you restart all processes you can basically forget the first run because of the OS disc cache, JIT and GCs make the measured timings very flexible. When you are in need of a random number generator you should measure cold startup times of a sufficiently complex system. After the first run you can try again getting different and much lower numbers. Now try again at least two times to get some feeling how stable the numbers are. Oh and try to do the same thing the next day. It might be that the bottleneck you found yesterday is gone today. Thanks to GC and other random stuff it can become pretty hard to find stuff worth optimizing if no big bottlenecks except bloatloads of code are left anymore. When I have found a spot worth optimizing I do make the code changes and do measure again to check if something has changed. If it has got slower and I am certain that my change should have made it faster I can blame the GC again. The thing is that if you optimize stuff and you allocate less objects the GC times will shift to some other location. If you are unlucky it will make your faster working code slower because you see now GCs at times where none were before. This is where the stuff does get really tricky. A safe escape hatch is to create a repro of the slow code in an isolated application so you can change things fast in a reliable manner. Then the normal profilers do also start working again. As Vance Morrison does point out it is much more complex to profile a system against the wall clock compared to optimize for CPU time. The reason is that for wall clock time analysis you need to understand how your system does work and which threads (if you have not one but perhaps 20) are causing a visible delay to the end user and which threads can wait a long time without affecting the user experience at all. Next time: Commercial profiler shootout.

    Read the article

  • Overriding GetHashCode in a mutable struct - What NOT to do?

    - by Kyle Baran
    I am using the XNA Framework to make a learning project. It has a Point struct which exposes an X and Y value; for the purpose of optimization, it breaks the rules for proper struct design, since its a mutable struct. As Marc Gravell, John Skeet, and Eric Lippert point out in their respective posts about GetHashCode() (which Point overrides), this is a rather bad thing, since if an object's values change while its contained in a hashmap (ie, LINQ queries), it can become "lost". However, I am making my own Point3D struct, following the design of Point as a guideline. Thus, it too is a mutable struct which overrides GetHashCode(). The only difference is that mine exposes and int for X, Y, and Z values, but is fundamentally the same. The signatures are below: public struct Point3D : IEquatable<Point3D> { public int X; public int Y; public int Z; public static bool operator !=(Point3D a, Point3D b) { } public static bool operator ==(Point3D a, Point3D b) { } public Point3D Zero { get; } public override int GetHashCode() { } public override bool Equals(object obj) { } public bool Equals(Point3D other) { } public override string ToString() { } } I have tried to break my struct in the way they describe, namely by storing it in a List<Point3D>, as well as changing the value via a method using ref, but I did not encounter they behavior they warn about (maybe a pointer might allow me to break it?). Am I being too cautious in my approach, or should I be okay to use it as is?

    Read the article

  • SQL SERVER – Import CSV into Database – Transferring File Content into a Database Table using CSVexpress

    - by pinaldave
    One of the most common data integration tasks I run into is a desire to move data from a file into a database table.  Generally the user is familiar with his data, the structure of the file, and the database table, but is unfamiliar with data integration tools and therefore views this task as something that is difficult.  What these users really need is a point and click approach that minimizes the learning curve for the data integration tool.  This is what CSVexpress (www.CSVexpress.com) is all about!  It is based on expressor Studio, a data integration tool I’ve been reviewing over the last several months. With CSVexpress, moving data between data sources can be as simple as providing the database connection details, describing the structure of the incoming and outgoing data and then connecting two pre-programmed operators.   There’s no need to learn the intricacies of the data integration tool or to write code.  Let’s look at an example. Suppose I have a comma separated value data file with data similar to the following, which is a listing of terminated employees that includes their hiring and termination date, department, job description, and final salary. EMP_ID,STRT_DATE,END_DATE,JOB_ID,DEPT_ID,SALARY 102,13-JAN-93,24-JUL-98 17:00,Programmer,60,"$85,000" 101,21-SEP-89,27-OCT-93 17:00,Account Representative,110,"$65,000" 103,28-OCT-93,15-MAR-97 17:00,Account Manager,110,"$75,000" 304,17-FEB-96,19-DEC-99 17:00,Marketing,20,"$45,000" 333,24-MAR-98,31-DEC-99 17:00,Data Entry Clerk,50,"$35,000" 100,17-SEP-87,17-JUN-93 17:00,Administrative Assistant,90,"$40,000" 334,24-MAR-98,31-DEC-98 17:00,Sales Representative,80,"$40,000" 400,01-JAN-99,31-DEC-99 17:00,Sales Manager,80,"$55,000" Notice the concise format used for the date values, the fact that the termination date includes both date and time information, and that the salary is clearly identified as money by the dollar sign and digit grouping.  In moving this data to a database table I want to express the dates using a format that includes the century since it’s obvious that this listing could include employees who left the company in both the 20th and 21st centuries, and I want the salary to be stored as a decimal value without the currency symbol and grouping character.  Most data integration tools would require coding within a transformation operation to effect these changes, but not expressor Studio.  Directives for these modifications are included in the description of the incoming data. Besides starting the expressor Studio tool and opening a project, the first step is to create connection artifacts, which describe to expressor where data is stored.  For this example, two connection artifacts are required: a file connection, which encapsulates the file system location of my file; and a database connection, which encapsulates the database connection information.  With expressor Studio, I use wizards to create these artifacts. First click New Connection > File Connection in the Home tab of expressor Studio’s ribbon bar, which starts the File Connection wizard.  In the first window, I enter the path to the directory that contains the input file.  Note that the file connection artifact only specifies the file system location, not the name of the file. Then I click Next and enter a meaningful name for this connection artifact; clicking Finish closes the wizard and saves the artifact. To create the Database Connection artifact, I must know the location of, or instance name, of the target database and have the credentials of an account with sufficient privileges to write to the target table.  To use expressor Studio’s features to the fullest, this account should also have the authority to create a table. I click the New Connection > Database Connection in the Home tab of expressor Studio’s ribbon bar, which starts the Database Connection wizard.  expressor Studio includes high-performance drivers for many relational database management systems, so I can simply make a selection from the “Supplied database drivers” drop down control.  If my desired RDBMS isn’t listed, I can optionally use an existing ODBC DSN by selecting the “Existing DSN” radio button. In the following window, I enter the connection details.  With Microsoft SQL Server, I may choose to use Windows Authentication rather than rather than account credentials.  After clicking Next, I enter a meaningful name for this connection artifact and clicking Finish closes the wizard and saves the artifact. Now I create a schema artifact, which describes the structure of the file data.  When expressor reads a file, all data fields are typed as strings.  In some use cases this may be exactly what is needed and there is no need to edit the schema artifact.  But in this example, editing the schema artifact will be used to specify how the data should be transformed; that is, reformat the dates to include century designations, change the employee and job ID’s to integers, and convert the salary to a decimal value. Again a wizard is used to create the schema artifact.  I click New Schema > Delimited Schema in the Home tab of expressor Studio’s ribbon bar, which starts the Database Connection wizard.  In the first window, I click Get Data from File, which then displays a listing of the file connections in the project.  When I click on the file connection I previously created, a browse window opens to this file system location; I then select the file and click Open, which imports 10 lines from the file into the wizard. I now view the file’s content and confirm that the appropriate delimiter characters are selected in the “Field Delimiter” and “Record Delimiter” drop down controls; then I click Next. Since the input file includes a header row, I can easily indicate that fields in the file should be identified through the corresponding header value by clicking “Set All Names from Selected Row. “ Alternatively, I could enter a different identifier into the Field Details > Name text box.  I click Next and enter a meaningful name for this schema artifact; clicking Finish closes the wizard and saves the artifact. Now I open the schema artifact in the schema editor.  When I first view the schema’s content, I note that the types of all attributes in the Semantic Type (the right-hand panel) are strings and that the attribute names are the same as the field names in the data file.  To change an attribute’s name and type, I highlight the attribute and click Edit in the Attributes grouping on the Schema > Edit tab of the editor’s ribbon bar.  This opens the Edit Attribute window; I can change the attribute name and select the desired type from the “Data type” drop down control.  In this example, I change the name of each attribute to the name of the corresponding database table column (EmployeeID, StartingDate, TerminationDate, JobDescription, DepartmentID, and FinalSalary).  Then for the EmployeeID and DepartmentID attributes, I select Integer as the data type, for the StartingDate and TerminationDate attributes, I select Datetime as the data type, and for the FinalSalary attribute, I select the Decimal type. But I can do much more in the schema editor.  For the datetime attributes, I can set a constraint that ensures that the data adheres to some predetermined specifications; a starting date must be later than January 1, 1980 (the date on which the company began operations) and a termination date must be earlier than 11:59 PM on December 31, 1999.  I simply select the appropriate constraint and enter the value (1980-01-01 00:00 as the starting date and 1999-12-31 11:59 as the termination date). As a last step in setting up these datetime conversions, I edit the mapping, describing the format of each datetime type in the source file. I highlight the mapping line for the StartingDate attribute and click Edit Mapping in the Mappings grouping on the Schema > Edit tab of the editor’s ribbon bar.  This opens the Edit Mapping window in which I either enter, or select, a format that describes how the datetime values are represented in the file.  Note the use of Y01 as the syntax for the year.  This syntax is the indicator to expressor Studio to derive the century by setting any year later than 01 to the 20th century and any year before 01 to the 21st century.  As each datetime value is read from the file, the year values are transformed into century and year values. For the TerminationDate attribute, my format also indicates that the datetime value includes hours and minutes. And now to the Salary attribute. I open its mapping and in the Edit Mapping window select the Currency tab and the “Use currency” check box.  This indicates that the file data will include the dollar sign (or in Europe the Pound or Euro sign), which should be removed. And on the Grouping tab, I select the “Use grouping” checkbox and enter 3 into the “Group size” text box, a comma into the “Grouping character” text box, and a decimal point into the “Decimal separator” character text box. These entries allow the string to be properly converted into a decimal value. By making these entries into the schema that describes my input file, I’ve specified how I want the data transformed prior to writing to the database table and completely removed the requirement for coding within the data integration application itself. Assembling the data integration application is simple.  Onto the canvas I drag the Read File and Write Table operators, connecting the output of the Read File operator to the input of the Write Table operator. Next, I select the Read File operator and its Properties panel opens on the right-hand side of expressor Studio.  For each property, I can select an appropriate entry from the corresponding drop down control.  Clicking on the button to the right of the “File name” text box opens the file system location specified in the file connection artifact, allowing me to select the appropriate input file.  I indicate also that the first row in the file, the header row, should be skipped, and that any record that fails one of the datetime constraints should be skipped. I then select the Write Table operator and in its Properties panel specify the database connection, normal for the “Mode,” and the “Truncate” and “Create Missing Table” options.  If my target table does not yet exist, expressor will create the table using the information encapsulated in the schema artifact assigned to the operator. The last task needed to complete the application is to create the schema artifact used by the Write Table operator.  This is extremely easy as another wizard is capable of using the schema artifact assigned to the Read Table operator to create a schema artifact for the Write Table operator.  In the Write Table Properties panel, I click the drop down control to the right of the “Schema” property and select “New Table Schema from Upstream Output…” from the drop down menu. The wizard first displays the table description and in its second screen asks me to select the database connection artifact that specifies the RDBMS in which the target table will exist.  The wizard then connects to the RDBMS and retrieves a list of database schemas from which I make a selection.  The fourth screen gives me the opportunity to fine tune the table’s description.  In this example, I set the width of the JobDescription column to a maximum of 40 characters and select money as the type of the LastSalary column.  I also provide the name for the table. This completes development of the application.  The entire application was created through the use of wizards and the required data transformations specified through simple constraints and specifications rather than through coding.  To develop this application, I only needed a basic understanding of expressor Studio, a level of expertise that can be gained by working through a few introductory tutorials.  expressor Studio is as close to a point and click data integration tool as one could want and I urge you to try this product if you have a need to move data between files or from files to database tables. Check out CSVexpress in more detail.  It offers a few basic video tutorials and a preview of expressor Studio 3.5, which will support the reading and writing of data into Salesforce.com. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, SQL, SQL Authority, SQL Documentation, SQL Download, SQL Query, SQL Server, SQL Tips and Tricks, SQLServer, T SQL, Technology

    Read the article

  • EM12c Release 4: Cloud Control to Major Tom...

    - by abulloch
    With the latest release of Enterprise Manager 12c, Release 4 (12.1.0.4) the EM development team has added new functionality to assist the EM Administrator to monitor the health of the EM infrastructure.   Taking feedback delivered from customers directly and through customer advisory boards some nice enhancements have been made to the “Manage Cloud Control” sections of the UI, commonly known in the EM community as “the MTM pages” (MTM stands for Monitor the Monitor).  This part of the EM Cloud Control UI is viewed by many as the mission control for EM Administrators. In this post we’ll highlight some of the new information that’s on display in these redesigned pages and explain how the information they present can help EM administrators identify potential bottlenecks or issues with the EM infrastructure. The first page we’ll take a look at is the newly designed Repository information page.  You can get to this from the main Setup menu, through Manage Cloud Control, then Repository.  Once this page loads you’ll see the new layout that includes 3 tabs containing more drill-down information. The Repository Tab The first tab, Repository, gives you a series of 6 panels or regions on screen that display key information that the EM Administrator needs to review from time to time to ensure that their infrastructure is in good health. Rather than go through every panel let’s call out a few and let you explore the others later yourself on your own EM site.  Firstly, we have the Repository Details panel. At a glance the EM Administrator can see the current version of the EM repository database and more critically, three important elements of information relating to availability and reliability :- Is the database in Archive Log mode ? Is the database using Flashback ? When was the last database backup taken ? In this test environment above the answers are not too worrying, however, Production environments should have at least Archivelog mode enabled, Flashback is a nice feature to enable prior to upgrades (for fast rollback) and all Production sites should have a backup.  In this case the backup information in the Control file indicates there’s been no recorded backups taken. The next region of interest to note on this page shows key information around the Repository configuration, specifically, the initialisation parameters (from the spfile). If you’re storing your EM Repository in a Cluster Database you can view the parameters on each individual instance using the Instance Name drop-down selector in the top right of the region. Additionally, you’ll note there is now a check performed on the active configuration to ensure that you’re using, at the very least, Oracle minimum recommended values.  Should the values in your EM Repository not meet these requirements it will be flagged in this table with a red X for non-compliance.  You can of-course change these values within EM by selecting the Database target and modifying the parameters in the spfile (and optionally, the run-time values if the parameter allows dynamic changes). The last region to call out on this page before moving on is the new look Repository Scheduler Job Status region. This region is an update of a similar region seen on previous releases of the MTM pages in Cloud Control but there’s some important new functionality that’s been added that customers have requested. First-up - Restarting Repository Jobs.  As you can see from the graphic, you can now optionally select a job (by selecting the row in the UI table element) and click on the Restart Job button to take care of any jobs which have stopped or stalled for any reason.  Previously this needed to be done at the command line using EMDIAG or through a PL/SQL package invocation.  You can now take care of this directly from within the UI. Next, you’ll see that a feature has been added to allow the EM administrator to customise the run-time for some of the background jobs that run in the Repository.  We heard from some customers that ensuring these jobs don’t clash with Production backups, etc is a key requirement.  This new functionality allows you to select the pencil icon to edit the schedule time for these more resource intensive background jobs and modify the schedule to avoid clashes like this. Moving onto the next tab, let’s select the Metrics tab. The Metrics Tab There’s some big changes here, this page contains new information regions that help the Administrator understand the direct impact the in-bound metric flows are having on the EM Repository.  Many customers have provided feedback that they are in the dark about the impact of adding new targets or large numbers of new hosts or new target types into EM and the impact this has on the Repository.  This page helps the EM Administrator get to grips with this.  Let’s take a quick look at two regions on this page. First-up there’s a bubble chart showing a comprehensive view of the top resource consumers of metric data, over the last 30 days, charted as the number of rows loaded against the number of collections for the metric.  The size of the bubble indicates a relative volume.  You can see from this example above that a quick glance shows that Host metrics are the largest inbound flow into the repository when measured by number of rows.  Closely following behind this though are a large number of collections for Oracle Weblogic Server and Application Deployment.  Taken together the Host Collections is around 0.7Mb of data.  The total information collection for Weblogic Server and Application Deployments is 0.38Mb and 0.37Mb respectively. If you want to get this information breakdown on the volume of data collected simply hover over the bubble in the chart and you’ll get a floating tooltip showing the information. Clicking on any bubble in the chart takes you one level deeper into a drill-down of the Metric collection. Doing this reveals the individual metric elements for these target types and again shows a representation of the relative cost - in terms of Number of Rows, Number of Collections and Storage cost of data for each Metric type. Looking at another panel on this page we can see a different view on this data. This view shows a view of the Top N metrics (the drop down allows you to select 10, 15 or 20) and sort them by volume of data.  In the case above we can see the largest metric collection (by volume) in this case (over the last 30 days) is the information about OS Registered Software on a Host target. Taken together, these two regions provide a powerful tool for the EM Administrator to understand the potential impact of any new targets that have been discovered and promoted into management by EM12c.  It’s a great tool for identifying the cause of a sudden increase in Repository storage consumption or Redo log and Archive log generation. Using the information on this page EM Administrators can take action to mitigate any load impact by deploying monitoring templates to the targets causing most load if appropriate.   The last tab we’ll look at on this page is the Schema tab. The Schema Tab Selecting this tab brings up a window onto the SYSMAN schema with a focus on Space usage in the EM Repository.  Understanding what tablespaces are growing, at what rate, is essential information for the EM Administrator to stay on top of managing space allocations for the EM Repository so that it works as efficiently as possible and performs well for the users.  Not least because ensuring storage is managed well ensures continued availability of EM for monitoring purposes. The first region to highlight here shows the trend of space usage for the tablespaces in the EM Repository over time.  You can see the upward trend here showing that storage in the EM Repository is being consumed on an upward trend over the last few days here. This is normal as this EM being used here is brand new with Agents being added daily to bring targets into monitoring.  If your Enterprise Manager configuration has reached a steady state over a period of time where the number of new inbound targets is relatively small, the metric collection settings are fairly uniform and standardised (using Templates and Template Collections) you’re likely to see a trend of space allocation that plateau’s. The table below the trend chart shows the Top 20 Tables/Indexes sorted descending by order of space consumed.  You can switch the trend view chart and corresponding detail table by choosing a different tablespace in the EM Repository using the drop-down picker on the top right of this region. The last region to highlight on this page is the region showing information about the Purge policies in effect in the EM Repository. This information is useful to illustrate to EM Administrators the default purge policies in effect for the different categories of information available in the EM Repository.  Of course, it’s also been a long requested feature to have the ability to modify these default retention periods.  You can also do this using this screen.  As there are interdependencies between some data elements you can’t modify retention policies on a feature by feature basis.  Instead, retention policies take categories of information and bundles them together in Groups.  Retention policies are modified at the Group Level.  Understanding the impact of this really deserves a blog post all on it’s own as modifying these can have a significant impact on both the EM Repository’s storage footprint and it’s performance.  For now, we’re just highlighting the features visibility on these new pages. As a user of EM12c we hope the new features you see here address some of the feedback that’s been given on these pages over the past few releases.  We’ll look out for any comments or feedback you have on these pages ! 

    Read the article

  • Problem with SLATEC routine usage with gfortran

    - by user39461
    I am trying to compute the Bessel function of the second kind (Bessel_y) using the SLATEC's Amos library available on Netlib. Here is the SLATEC code I use. Below I have pasted my test program that calls SLATEC routine CBESY. PROGRAM BESSELTEST IMPLICIT NONE REAL:: FNU INTEGER, PARAMETER :: N = 2, KODE = 1 COMPLEX,ALLOCATABLE :: CWRK (:), CY (:) COMPLEX:: Z, ci INTEGER :: NZ, IERR ALLOCATE(CWRK(N), CY(N)) ci = cmplx (0.0, 1.0) FNU = 0.0e0 Z = CMPLX(0.3e0, 0.4e0) CALL CBESY(Z, FNU, KODE, N, CY, NZ, CWRK, IERR) WRITE(*,*) 'CY: ', CY WRITE(*,*) 'IERR: ', IERR STOP END PROGRAM And here is the output of the above program: CY: ( 5.78591091E-39, 5.80327020E-39) ( 0.0000000 , 0.0000000 ) IERR: 4 Ierr = 4 meaning there is some problem with the input itself. To be precise, the IERR = 4 means the following as per the header info in CBESY.f file: ! IERR=4, CABS(Z) OR FNU+N-1 TOO LARGE - NO COMPUTA- ! TION BECAUSE OF COMPLETE LOSSES OF SIGNIFI- ! CANCE BY ARGUMENT REDUCTION Clearly, CABS(Z) (which is 0.50) or FNU + N - 1 (which is 1.0) are not too large but still the routine CBESY throws the error message number 4 as above. The CY array should have following values for the argument given in above code: CY(1) = -0.4983 + 0.6700i CY(2) = -1.0149 + 0.9485i These values are computed using Matlab. I can't figure out what's the problem when I call CBESY from SLATEC library. Any clues? Much thanks for the suggestions/help. PS: if it is of any help, I used gfortran to compile, link and then create the SLATEC library file ( the .a file ) which I keep in the same directory as my test program above. shell command to execute above code: gfortran -c BesselTest.f95 gfortran -o a *.o libslatec.a a GD.

    Read the article

  • How do I lookup a 'quantity' of items in excel?

    - by KronoS
    Let's say I have a quatity of items: 1 2 3 4 5 4 3 2 1 2 3 4 in a column of cells. What I want to be able to do is count the quantity how many unique "items" there are in this array: 1 -- 2 2 -- 3 3 -- 3 4 .. 3 And so forth. I want the table to look like this: Also, is there a way to accomplish this if I don't know all of the values of the array to begin with? I'm looking for a way to have excel search an array, find a unique value, count how many times that value is in the array, and then move onto the next values.

    Read the article

  • APC (PHP Cache) Uptime 0 minutes, not caching

    - by Jussi
    My goal is to implement APC for opcode cache for a drupal 6 production site. I have so far tested APC with several php files with and without including other php files with include_once. Also tried to tweak the apc.ini values for shm_size, apc.include_once_override and apc.stat. Restarted apache every time. Resulting in apc.php not showing any changes in any values. (except of course the changed apc.ini values are shown as they should) Every time i refresh the apc.php test page, the start time resets as the current time showing uptime 0 minutes. apc.php -testpage shows: General Cache InformationAPC Version 3.1.9 PHP Version 5.2.10 APC Host xxxx.xx.xx Server Software Apache/2.2.3 (CentOS) Shared Memory 1 Segment(s) with 128.0 MBytes (mmap memory, pthread mutex Locks locking) Start Time 2011/07/26 11:53:56 Uptime 0 minutes File Upload Support 1 Cached Files 0 ( 0.0 Bytes) Hits 1 Misses 1 Request Rate (hits, misses) 2.00 cache requests/second Hit Rate 1.00 cache requests/second Miss Rate 1.00 cache requests/second Insert Rate 0.00 cache requests/second Cache full count 0 Cached Variables 0 ( 0.0 Bytes) Hits 0 Misses 0 Request Rate (hits, misses) 0.00 cache requests/second Hit Rate 0.00 cache requests/second Miss Rate 0.00 cache requests/second Insert Rate 0.00 cache requests/second Cache full count 0 apc.cache_by_default 1 apc.canonicalize 1 apc.coredump_unmap 0 apc.enable_cli 0 apc.enabled 1 apc.file_md5 0 apc.file_update_protection 2 apc.filters apc.gc_ttl 3600 apc.include_once_override 0 apc.lazy_classes 0 apc.lazy_functions 0 apc.max_file_size 16 apc.mmap_file_mask /tmp/apcphp5.095eRm apc.num_files_hint 1024 apc.preload_path apc.report_autofilter 0 apc.rfc1867 0 apc.rfc1867_freq 0 apc.rfc1867_name APC_UPLOAD_PROGRESS apc.rfc1867_prefix upload_ apc.rfc1867_ttl 3600 apc.serializer default apc.shm_segments 1 apc.shm_size 128M apc.slam_defense 0 apc.stat 0 apc.stat_ctime 0 apc.ttl 7200 apc.use_request_time 1 apc.user_entries_hint 4096 apc.user_ttl 7200 apc.write_lock 1 Host Status Diagrams: Free: 128.0 MBytes (100.0%) Hits: 1 (50.0%) Used: 20.3 KBytes (0.0%) Misses: 1 (50.0%) Detailed Memory Usage and Fragmentation: Fragmentation: 0% phpinfo shows: Server API CGI/FastCGI APC: Version 3.1.9 APC Debugging Enabled MMAP Support Enabled MMAP File Mask /tmp/apcphp5.JkKDk7 Locking type pthread mutex Locks Serialization Support php Revision $Revision: 308812 $ Build Date Jul 21 2011 14:31:12 I followed these steps to find if suexec settings would prevent caching: http://www.litespeedtech.com/support/forum/showthread.php?t=4189 [root@host /]# ps -ef|grep lsphp root 20402 17833 0 11:21 pts/0 00:00:00 grep lsphp [root@host /]# ps -waux root 17833 0.0 0.1 5004 1484 pts/0 S 10:39 0:00 bash ..indicates that there is no lsphp running on the host also I read the following article and comments, concluding that in my case the problem is not the suexec as the user apache is the httpd process owner http://www.brandonturner.net/blog/2009/07/fastcgi_with_php_opcode_cache/ also suexec command is not recognized when logged and launced as root @ host also i'm almost confident that there is no cPanel running on the host to check if a setting there would reset the running cache process at some interval This leaves me with few clues where to head next. I tried to set (with chown and chgrp) apache as the owner of the apc.php file and some test php files resulting in 500 server error. Is there a way to check if the file permissions prevent the apc stay running? I'm tremendously grateful for any suggestions or help.

    Read the article

  • How to cross-reference many character encodings with ASCII OR UTFx?

    - by Garet Claborn
    I'm working with a binary structure, the goal of which is to index the significance of specific bits for any character encoding so that we may trigger events while doing specific checks against the profile. Each character encoding scheme has an associated system record. This record's leading value will be a C++ unsigned long long binary value and signifies the length, in bits, of encoded characters. Following the length are three values, each is a bit field of that length. offset_mask - defines the occurrence of non-printable characters within the min,max of print_mask range_mask - defines the occurrence of the most popular 50% of printable characters print_mask - defines the occurrence value of printable characters The structure of profiles has changed from the op of this question. Most likely I will try to factorize or compress these values in the long-term instead of starting out with ranges after reading more. I have to write some of the core functionality for these main reasons. It has to fit into a particular event architecture we are using, Better understanding of character encoding. I'm about to need it. Integrating into non-linear design is excluding many libraries without special hooks. I'm unsure if there is a standard, cross-encoding mechanism for communicating such data already. I'm just starting to look into how chardet might do profiling as suggested by @amon. The Unicode BOM would be easily enough (for my current project) if all encodings were Unicode. Of course ideally, one would like to support all encodings, but I'm not asking about implementation - only the general case. How can these profiles be efficiently populated, to produce a set of bitmasks which we can use to match strings with common characters in multiple languages? If you have any editing suggestions please feel free, I am a lightweight when it comes to localization, which is why I'm trying to reach out to the more experienced. Any caveats you may be able to help with will be appreciated.

    Read the article

  • MVC OnActionExecuting to Redirect

    - by Aligned
    Originally posted on: http://geekswithblogs.net/Aligned/archive/2014/08/12/mvc-onactionexecuting-to-redirect.aspxI recently had the following requirements in an MVC application: Given a new user that still has the default password When they first login Then the user must change their password and optionally provide contact information I found that I can override the OnActionExecuting method in a BaseController class.public class BaseController : Controller { [Inject] public ISessionManager SessionManager { get; set; } protected override void OnActionExecuting(ActionExecutingContext filterContext) { // call the base method first base.OnActionExecuting(filterContext); // if the user hasn't changed their password yet, force them to the welcome page if (!filterContext.RouteData.Values.ContainsValue("WelcomeNewUser")) { var currentUser = this.SessionManager.GetCurrentUser(); if (currentUser.FusionUser.IsPasswordChangeRequired) { filterContext.Result = new RedirectResult("/welcome"); } } } } Better yet, you can use an ActionFilterAttribute (and here) and apply the attribute to the Base or individual controllers./// <summary> /// Redirect the user to the WelcomePage if the FusionUser.IsPasswordChangeRequired is true; /// </summary> public class WelcomePageRedirectActionFilterAttribute : ActionFilterAttribute { [Inject] public ISessionManager SessionManager { get; set; } public override void OnActionExecuting(ActionExecutingContext actionContext) { base.OnActionExecuting(actionContext); // if the user hasn't changed their password yet, force them to the welcome page if (actionContext.RouteData.Values.ContainsValue("WelcomeNewUser")) { return; } var currentUser = this.SessionManager.GetCurrentUser(); if (currentUser.FusionUser.IsPasswordChangeRequired) { actionContext.Result = new RedirectResult("/welcome"); } } }  [WelcomePageRedirectActionFilterAttribute] public class BaseController : Controller { ... } The requirement is now met.

    Read the article

  • Office 365 Powershell - Export user, license type, and company field to csv file

    - by ASGJim
    I need to be able to export user name or email address (doesn't matter which), company (from the company field under the organization tab in a user account of the exchange admin console), and license type (e.g. exchange online e1, exchange online kiosk etc...) I am able to export both values in two statements into two separate files but that doesn't do me much good. I can export the username and license type with the following: Get-MSOLUser | % { $user=$_; $_.Licenses | Select {$user.displayname},AccountSKuid } | Export-CSV "sample.csv" -NoTypeInformation And, I can get the company values with the following: Get-User | select company | Export-CSV sample.csv Someone on another forum suggested this - $index = @{} Get-User | foreach-object {$index.Add($_.userprincipalname,$_.company)} Get-MsolUser | ForEach-Object { write-host $_.userprincipalname, $index[$_.userprincipalname], $_.licenses.AccountSku.Skupartnumber} That seems like it should work but it doesn't display any license info in my powershell, it's just blank. Also I wouldn't know how to export that to a csv file. Any help would be appreciated. Thanks.

    Read the article

  • Tuning Linux IP routing parameters -- secret_interval and tcp_mem

    - by Jeff Atwood
    We had a little failover problem with one of our HAProxy VMs today. When we dug into it, we found this: Jan 26 07:41:45 haproxy2 kernel: [226818.070059] __ratelimit: 10 callbacks suppressed Jan 26 07:41:45 haproxy2 kernel: [226818.070064] Out of socket memory Jan 26 07:41:47 haproxy2 kernel: [226819.560048] Out of socket memory Jan 26 07:41:49 haproxy2 kernel: [226822.030044] Out of socket memory Which, per this link, apparently has to do with low default settings for net.ipv4.tcp_mem. So we increased them by 4x from their defaults (this is Ubuntu Server, not sure if the Linux flavor matters): current values are: 45984 61312 91968 new values are: 183936 245248 367872 After that, we started seeing a bizarre error message: Jan 26 08:18:49 haproxy1 kernel: [ 2291.579726] Route hash chain too long! Jan 26 08:18:49 haproxy1 kernel: [ 2291.579732] Adjust your secret_interval! Shh.. it's a secret!! This apparently has to do with /proc/sys/net/ipv4/route/secret_interval which defaults to 600 and controls periodic flushing of the route cache The secret_interval instructs the kernel how often to blow away ALL route hash entries regardless of how new/old they are. In our environment this is generally bad. The CPU will be busy rebuilding thousands of entries per second every time the cache is cleared. However we set this to run once a day to keep memory leaks at bay (though we've never had one). While we are happy to reduce this, it seems odd to recommend dropping the entire route cache at regular intervals, rather than simply pushing old values out of the route cache faster. After some investigation, we found /proc/sys/net/ipv4/route/gc_elasticity which seems to be a better option for keeping the route table size in check: gc_elasticity can best be described as the average bucket depth the kernel will accept before it starts expiring route hash entries. This will help maintain the upper limit of active routes. We adjusted elasticity from 8 to 4, in the hopes of the route cache pruning itself more aggressively. The secret_interval does not feel correct to us. But there are a bunch of settings and it's unclear which are really the right way to go here. /proc/sys/net/ipv4/route/gc_elasticity (8) /proc/sys/net/ipv4/route/gc_interval (60) /proc/sys/net/ipv4/route/gc_min_interval (0) /proc/sys/net/ipv4/route/gc_timeout (300) /proc/sys/net/ipv4/route/secret_interval (600) /proc/sys/net/ipv4/route/gc_thresh (?) rhash_entries (kernel parameter, default unknown?) We don't want to make the Linux routing worse, so we're kind of afraid to mess with some of these settings. Can anyone advise which routing parameters are best to tune, for a high traffic HAProxy instance?

    Read the article

  • MaxClients, Server Limits etc

    - by Moe
    Hello, I'm having some problems with my Server. It's getting quite a bit of traffic and is very slow, and sometimes inaccessible by my users. Here are the server specs: CPU: Intel(R) Xeon(R) CPU E5620 @ 2.40GHz - 16 Processors RAM: 2GB The Values for the Apache Config are: StartServers: 5 MaxSpareServers: 10 MinSpareServers: 5 MaxClients: 150 ServerLimit: 256 MaxRequestsPerChild: 1000 KeepAlive: On KeepAliveTimeout: 5 MaxKeepAliveRequests: 100 TimeOut: 300 What would be optiminal values for a server of my configuration to support the maximum amount of users at a reasonable speed without killing the server! Thank you.

    Read the article

  • How do I pipe a list of numbers straight from the shell into a command?

    - by learnvst
    How do I pipe a list of numbers straight from the shell into a command? For exampe something like this [1,2,3,4] | sort would give 1 2 3 4 EDIT: In response to the answers kindly posted so far . . . I ask this, because I want to quickly test and debug a console application that takes many numbers as it input without having to type lots of individual values followed by carriage returns. I'd like to just type in the 'one liner' and hit the up arrow now and then to replay the command. Ideally, I'd like to do this without using a text file containing the values (which would obviously be the most simple way to do this.)

    Read the article

  • MySQL replication hung after slave goes offline and comes back online again

    - by Ed Manet
    I have a master server and several slave servers replicating a single database. I am using in MySQL 5.0 in SLES 11. During fault tolerance testing I found that when the slave's network connection is broken (cable un-plugged) and then restored, replication hangs. It shows no errors and the slave appears to be running but the Read_Master_Log_Pos and Exec_Master_Log_Pos values do not match the log postion on the master server. The Slave_IO_State is "Waiting for master to send event". The Slave_IO_Running and Slave_SQL_Running values are both are "Yes". The Master_Log_File and Relay_Master_Log_File match. If I stop and start the slave or restart the mysql daemon, replication starts working again. Any ideas on what I can do about this?

    Read the article

< Previous Page | 231 232 233 234 235 236 237 238 239 240 241 242  | Next Page >