  • Virtual machine : is it possible to run a 32 bits guest OS on a 64 bits host OS?

    - by Cédric Girard
    I am a software developer, and I need to use old version of Borland/Embarcadero Delphi 7 for one software. The others ones are PHP software. I will have soon a 64 bits PC, running Linux, but I need a Windows 32 bits virtual machine for Delphi (because Delphi 7 is a bit old, and our clients still use Windows XP 32 bits systems). I already have a VM under virtualbox for my Delphi environment. Will it run fine, or will I have some problem?

    Read the article

  • VirtualBox OSE: Install Guest OS On Headless Host Via VNC?

    - by Eddie Parker
    I've remotely installed VirtualBox OSE on my Gentoo box at home. I have everything set up and ready for the OS. However all the documentation I've read seems to say that you can only use the PUEL version in order to get remote access during installs - does anyone know if it's possible to do similar with the OSE but using VNC? Links to documentation or tutorials would be welcome, apparently my Google-Fu is failing me, if it's out there. Thanks.

    Read the article

  • Configure IPv6 routing

    - by godlark
    I've got IPv6 addresses from SIXXS. My host is connected with SIXXS network over a AICCU tunnel ("sixxs" interface). My host address is 2001:::2, the host on the end has address 2001:::1. On my host IPv6 is fully accessible. I have problem with configuring IPv6 network on VMs. I use VirtualBox, the VM (Ubuntu) uses tap1 (on the host bridged by br0) #!/bin/sh PATH=/sbin:/usr/bin:/bin:/usr/bin:/usr/sbin # create a tap tunctl -t tap1 ip link set up dev tap1 # create the bridge brctl addbr br0 brctl addif br0 tap1 # set the IP address and routing ip link set up dev br0 ip -6 route del 2001:6a0:200:172::/64 dev sixxs ip -6 route add 2001:6a0:200:172::1 dev sixxs ip -6 addr add 2001:6a0:200:172::2/64 dev br0 ip -6 route add 2001:6a0:200:172::2/64 dev br0 Host: routing table: 2001:6a0:200:172::1 dev sixxs metric 1024 2001:6a0:200:172::/64 dev br0 proto kernel metric 256 2001:6a0:200:172::/64 dev br0 metric 1024 2000::/3 dev sixxs metric 1024 fe80::/64 dev eth0 proto kernel metric 256 fe80::/64 dev sixxs proto kernel metric 256 fe80::/64 dev br0 proto kernel metric 256 fe80::/64 dev tap1 proto kernel metric 256 default via 2001:6a0:200:172::1 dev sixxs metric 1024 Guest: interface eth1 (it is connected with tap1): auto eth1 iface eth1 inet6 static address 2001:6a0:200:172::3 netmask 64 gateway 2001:6a0:200:172::2 Guest: routing table 2001:6a0:200:172::/64 dev eth1 proto kernel metric 256 fe80::/64 dev eth0 proto kernel metric 256 fe80::/64 dev eth1 proto kernel metric 256 default via 2001:6a0:200:172::2 dev eth1 metric 1024 The guest pings to the host, the host pings to the guest, the host pings to 2001:6a0:200:172::1, but the guest doesn't ping to 2001:6a0:200:172::1. The guest tries to ping, on the host (by tcdump) I can capture its packets, but the host doesn't send them to 2001:6a0:200:172::1. What have I missed in configuration?

    Read the article

  • Hyper-V Guests Dying

    - by Jon Rauschenberger
    I just hit my THIRD instance of a Hyper-V guest machine dying with the exact same behavior. In all three instances we are hosting WS2008 guests on a WS2008 host. AFter a config change, we reboot the guest and the guest OS comes up but in a very cripled state. Specifically, we are able to log into the guest, but can't launch any apps and the guest never comes active on the network. I opened a support ticket with MS the second time this happened and they focused in on the DCOM subsystem not coming up...best explanation they could provide was that permissions on key system files got corrupted. I eventually gave up on the ticket after close to 10 hours on the phone trying different things that were going no where. What really concerns me is that we have now seen the exact same thing happen to a guest hosted on a completly differet host machine. There is zero hardware overlap between the two. Has anyone seen this before?? It's really odd behavior, but it also seems like there's a pattern here that's concerning me. Thanks, jon

    Read the article

  • Sharing disk volumes across OpenVZ guests to reduce Package Management Overhead

    - by andyortlieb
    Is it feasible to create a single "master" OpenVZ guest who would only be used for package management, and use something like mount --bind on several other OpenVZ guests sort of trick them into using the environment installed by the master guest? The point of this would be so that users can maintain their own containers, and yet stay in sync with the master development environment, so they'll always have the latest & greatest requirements without worrying too much about system administration. If they need to install their own packages, could put them in /opt, or /usr/local (or set a path to their home directory)? To rephrase, I would like several (developer's, for example) OpenVZ guests whose /bin, /usr (and so on...) actually refer to the same disk location as that of a master OpenVZ guest who can be started up to install and update common packages for the environment to be shared by all of this group of OpenVZ guests. For what it's worth, we're running Debian 6. Edit: I have tried mounting (bind, and readonly) /bin, /lib, /sbin, /usr in this fashion and it refuses to start the containers stating that files are already mounted or otherwise in use: Starting container ... vzquota : (error) Quota on syscall for id 1102: Device or resource busy vzquota : (error) Possible reasons: vzquota : (error) - Container's root is already mounted vzquota : (error) - there are opened files inside Container's private area vzquota : (error) - your current working directory is inside Container's vzquota : (error) private area vzquota : (error) Currently used file(s): /var/lib/vz/private/1102/sbin /var/lib/vz/private/1102/usr /var/lib/vz/private/1102/lib /var/lib/vz/private/1102/bin vzquota on failed [3] If I unmount these four volumes, and start the guest, and then mount them after the guest has started, the guest never sees them mounted.

    Read the article

  • windows 2003 under Hyper-V - can't send/receive ping

    - by glaucon
    I've installed Windows 2003 x64 R2 SP2 under Hyper-V (the Windows Pro 8 edition). I have a NIC configured but I can't move any traffic on it. In particular I can't send or receive Pings. Scoreboard There is a second VM running Ubuntu under the Windows 8 host which is able to send and receive pings from the host O/S . When I try to ping from Windows 2003 guest to Windows 8 host I get 'Request Timed Out'. When I try to ping from Windows 8 host to Windows 2003 guest I get 'Reply from 192.168.10.107 Destination Host Unreachable'. There's no problem pinging from the Ubuntu guest to the Windows 8 host and no problem pinging from the Windows 8 host to the Unbuntu guest. Environment Integration services are installed on Windows 2003. The windows 2003 needs a static IP address of 192.168.10.15. The Windows 2003 ipconfig output looks like this : While the host o/s ipconfig output looks like this : Event Logs The only things I can see in the event logs which is (a) looks signifcant and (b) is not related to the lack of networking is this : I'm not sure if that's significant or not. Hyper-V and NICs When the Windows 2003 guest was first booted it had no NIC; I subsequently added a 'Legacy Network Connector' which I couldn't get Windows 2003 to recognise; I subsequently removed that and added a 'Standard Network Connector' and at least on the surface this works ... only it doesn't. 'Virtual Network Type' is external. Although I've only mentioned ping there's no other evidence of network activity. 'Allow incoming echo request' is enabled on the Windows 2003 guest. HELP ? What else should I look at or do to resolve this problem ? EDIT 1: I should have said that I turned off the firewall on the W2003 server for a while and retested the pings; same result.

    Read the article

  • Slow performance on VMWare Linux server after Tomcat install

    - by Loftx
    We have a VMWare ESXi 4.1 server hosting a number of Linux and Windows guests. Recently a new Linux guest was added to this server and seemed to be performing well. Tomcat and some other applications on this server were then installed which seem to have caused the server to run really slowly without any obvious resource issues. Slow performance include: The time taken to bring up the password prompt over ssh takes a few seconds when it was previously instantaneous. The time taken to unzip a zip file which was previously a few seconds now takes around 30 seconds The time taken to compile vmware tools has increased by similar factors Both the VMWare console and monitoring commands don't report any issues with high CPU or memory usage but something is obviously slowing the server down somehow. Does anyone have any ideas what may be causing this issue and how it can be resolved? Thanks, Tom Edit As per your questions I’ve looked at some of the performance indicators on both the VM host and VM guest indicated. Firstly I tried reserving the full amount of memory (3gb) for this VM – no other machines on this server have any memory reservation. The swap in rate and swap out rate for the VM host and guest are now both zero. Balloon memory on the guest is zero and on the host is 3.5gb (total memory on the host is 12gb) The swap rate for the guest is also zero. Swap used by the host is 200mb on average. Compression and decompression rates for the host and guest are zero. Command aborts for the host are zero. Read latency is very low – maximum 10ms average 0.8ms. Write latency is higher – a few spikes to 170ms but mostly around 25ms – is this bad? Queue command latency is zero . Physical disk read latency averages 5ms but often 10ms Physical disk write latency averages 15ms but is often 20ms I hope this helps - let me know if you need any more information.

    Read the article

  • Surprising corruption and never-ending fsck after resizing a filesystem.

    - by Steve Kemp
    System in question has Debian Lenny installed, running a 2.65.27.38 kernel. System has 16Gb memory, and 8x1Tb drives running behind a 3Ware RAID card. The storage is managed via LVM. Short version: Running a KVM guest which had 1.7Tb storage allocated to it. The guest was reaching a full-disk. So we decided to resize the disk that it was running upon We're pretty familiar with LVM, and KVM, so we figured this would be a painless operation: Stop the KVM guest. Extend the size of the LVM partition: "lvextend -L+500Gb ..." Check the filesystem : "e2fsck -f /dev/mapper/..." Resize the filesystem: "resize2fs /dev/mapper/" Start the guest. The guest booted successfully, and running "df" showed the extra space, however a short time later the system decided to remount the filesystem read-only, without any explicit indication of error. Being paranoid we shut the guest down and ran the filesystem check again, given the new size of the filesystem we expected this to take a while, however it has now been running for 24 hours and there is no indication of how long it will take. Using strace I can see the fsck is "doing stuff", similarly running "vmstat 1" I can see that there are a lot of block input/output operations occurring. So now my question is threefold: Has anybody come across a similar situation? Generally we've done this kind of resize in the past with zero issues. What is the most likely cause? (3Ware card shows the RAID arrays of the backing stores as being A-OK, the host system hasn't rebooted and nothing in dmesg looks important/unusual) Ignoring brtfs + ext3 (not mature enough to trust) should we make our larger partitions in a different filesystem in the future to avoid either this corruption (whatever the cause) or reduce the fsck time? xfs seems like the obvious candidate?

    Read the article

  • Virtual box host-only adapter configuration

    - by Xoundboy
    I have VirtualBox 4 running on Win 7 with a Centos 6 guest VM set up for hosting my dev server. When I'm connected to my home network the guest can be accessed via a static IP address that I configured (192.168.56.2), but not when I'm in the office. I'm guessing that the DHCP server in the office doesn't have a gateway configured for the 192.168.56.x IP range. I read something about the VB host-only adapter that should allow me to set this guest VM up in such a way that I don't need to be on any network to be able to access the guest from the host using a static IP. I've not been able to find out exactly how to configure this though. Can anyone give me an example configuration, thanks. UPDATE: Thanks for your responses. I've now set up a single virtual network adapter in VirtualBox and set it to host-only: C:\Users\Ben>vboxmanage list hostonlyifs Name: VirtualBox Host-Only Ethernet Adapter GUID: d419ef62-3c46-4525-ad2d-be506c90459a Dhcp: Disabled IPAddress: 192.168.56.2 NetworkMask: 255.255.255.0 IPV6Address: fe80:0000:0000:0000:78e3:b200:5af3:2a57 IPV6NetworkMaskPrefixLength: 64 HardwareAddress: 08:00:27:00:94:e8 MediumType: Ethernet Status: Up VBoxNetworkName: HostInterfaceNetworking-VirtualBox Host-Only Ethernet Adapter On the guest I've set up eth0 to use the same IP address as the host-only adapter (192.168.56.2) but when I try to log in using Putty I still get "Network Error : connection refused". VirtualBox DHCP servier is enabled but I can't ping the gateway (192.168.56.1) from either host nor guest. There's no firewall running on either OS. What next?

    Read the article

  • On ESXi, guest machines hang for significant intervals compared to real machines. How can I fix this?

    - by Tarbox
    This is ESXi version 5.0.0. We plan on upgrading to 5.5 eventually. I have four code profiles, two taken on a real, unvirtualized machine, two taken on a virtual machine. Ordering the list of subroutines by time spent in each one, the two real profiles are practically identical. The two virtual profiles are different from each other and from the real profiles: a subset of subroutines are taking a lot more time on the virtual machines, and the subset is different for each run. The two virtual profiles take a similar amount of time, which is 3 times the amount of time the real profiles take. This gross "how long does it take?" result is consistent after hundreds of tests across three different virtual machines on two different host machines -- the virtual machine is just slower. I've only the code profiling on the four, however. Here's the most guilty set of lines: This is the real machine: 8µs $text = '' unless defined $text; 1.48ms foreach ( split( "\n", $text ) ) { This is the first run on the virtual machine: 20.1ms $text = '' unless defined $text; 1.49ms foreach ( split( "\n", $text ) ) { This is the second run on the virtual machine: 6µs $text = '' unless defined $text; 21.9ms foreach ( split( "\n", $text ) ) { My WAG is that the VM is swapping out the thread and then swapping it back in, destroying some level of cache in the process, but these code profiles were taken when the vm in question was the only active vm on the host, so... what? What does that mean? The guest itself is under light load, this is a latency problem for my users rather than throughput. The host is also under a light load, if I knew what resources to assign where, I could do it without worrying about the cost. I've attempted to lock memory, reserve cpu, assign a restrictive affinity, and disable hyperthread sharing. They don't help, it still takes the VM 2-4x the amount of time to do the same thing as the real machine. The host the tests were run on is 6x2.50GHz, Intel Xeon E5-26400 w/ 16gigs of ram. The guest exhibits the same performance under a wide combination of settings. The real machine is 4x2.13GHz, Xeon E5506 w/ 2 gigs of ram. Thank you for all advice.

    Read the article

  • Best Practices - which domain types should be used to run applications

    - by jsavit
    This post is one of a series of "best practices" notes for Oracle VM Server for SPARC (formerly named Logical Domains) One question that frequently comes up is "which types of domain should I use to run applications?" There used to be a simple answer in most cases: "only run applications in guest domains", but enhancements to T-series servers, Oracle VM Server for SPARC and the advent of SPARC SuperCluster have made this question more interesting and worth qualifying differently. This article reviews the relevant concepts and provides suggestions on where to deploy applications in a logical domains environment. Review: division of labor and types of domain Oracle VM Server for SPARC offloads many functions from the hypervisor to domains (also called virtual machines). This is a modern alternative to using a "thick" hypervisor that provides all virtualization functions, as in traditional VM designs, This permits a simpler hypervisor design, which enhances reliability, and security. It also reduces single points of failure by assigning responsibilities to multiple system components, which further improves reliability and security. In this architecture, management and I/O functionality are provided within domains. Oracle VM Server for SPARC does this by defining the following types of domain, each with their own roles: Control domain - management control point for the server, used to configure domains and manage resources. It is the first domain to boot on a power-up, is an I/O domain, and is usually a service domain as well. I/O domain - has been assigned physical I/O devices: a PCIe root complex, a PCI device, or a SR-IOV (single-root I/O Virtualization) function. It has native performance and functionality for the devices it owns, unmediated by any virtualization layer. Service domain - provides virtual network and disk devices to guest domains. Guest domain - a domain whose devices are all virtual rather than physical: virtual network and disk devices provided by one or more service domains. In common practice, this is where applications are run. Typical deployment A service domain is generally also an I/O domain: otherwise it wouldn't have access to physical device "backends" to offer to its clients. Similarly, an I/O domain is also typically a service domain in order to leverage the available PCI busses. Control domains must be I/O domains, because they boot up first on the server and require physical I/O. It's typical for the control domain to also be a service domain too so it doesn't "waste" the I/O resources it uses. A simple configuration consists of a control domain, which is also the one I/O and service domain, and some number of guest domains using virtual I/O. In production, customers typically use multiple domains with I/O and service roles to eliminate single points of failure: guest domains have virtual disk and virtual devices provisioned from more than one service domain, so failure of a service domain or I/O path or device doesn't result in an application outage. This is also used for "rolling upgrades" in which service domains are upgraded one at a time while their guests continue to operate without disruption. (It should be noted that resiliency to I/O device failures can also be provided by the single control domain, using multi-path I/O) In this type of deployment, control, I/O, and service domains are used for virtualization infrastructure, while applications run in guest domains. Changing application deployment patterns The above model has been widely and successfully used, but more configuration options are available now. Servers got bigger than the original T2000 class machines with 2 I/O busses, so there is more I/O capacity that can be used for applications. Increased T-series server capacity made it attractive to run more vertical applications, such as databases, with higher resource requirements than the "light" applications originally seen. This made it attractive to run applications in I/O domains so they could get bare-metal native I/O performance. This is leveraged by the SPARC SuperCluster engineered system, announced a year ago at Oracle OpenWorld. In SPARC SuperCluster, I/O domains are used for high performance applications, with native I/O performance for disk and network and optimized access to the Infiniband fabric. Another technical enhancement is the introduction of Direct I/O (DIO) and Single Root I/O Virtualization (SR-IOV), which make it possible to give domains direct connections and native I/O performance for selected I/O devices. A domain with either a DIO or SR-IOV device is an I/O domain. In summary: not all I/O domains own PCI complexes, and there are increasingly more I/O domains that are not service domains. They use their I/O connectivity for performance for their own applications. However, there are some limitations and considerations: at this time, a domain using physical I/O cannot be live-migrated to another server. There is also a need to plan for security and introducing unneeded dependencies: if an I/O domain is also a service domain providing virtual I/O go guests, it has the ability to affect the correct operation of its client guest domains. This is even more relevant for the control domain. where the ldm has to be protected from unauthorized (or even mistaken) use that would affect other domains. As a general rule, running applications in the service domain or the control domain should be avoided. To recap: Guest domains with virtual I/O still provide the greatest operational flexibility, including features like live migration. I/O domains can be used for applications with high performance requirements. This is used to great effect in SPARC SuperCluster and in general T4 deployments. Direct I/O (DIO) and Single Root I/O Virtualization (SR-IOV) make this more attractive by giving direct I/O access to more domains. Service domains should in general not be used for applications, because compromised security in the domain, or an outage, can affect other domains that depend on it. This concern can be mitigated by providing guests' their virtual I/O from more than one service domain, so an interruption of service in the service domain does not cause an application outage. The control domain should in general not be used to run applications, for the same reason. SPARC SuperCluster use the control domain for applications, but it is an exception: it's not a general purpose environment; it's an engineered system with specifically configured applications and optimization for optimal performance. These are recommended "best practices" based on conversations with a number of Oracle architects. Keep in mind that "one size does not fit all", so you should evaluate these practices in the context of your own requirements. Summary Higher capacity T-series servers have made it more attractive to use them for applications with high resource requirements. New deployment models permit native I/O performance for demanding applications by running them in I/O domains with direct access to their devices. This is leveraged in SPARC SuperCluster, and can be leveraged in T-series servers to provision high-performance applications running in domains. Carefully planned, this can be used to provide higher performance for critical applications.

    Read the article

  • Availability Best Practices on Oracle VM Server for SPARC

    - by jsavit
    This is the first of a series of blog posts on configuring Oracle VM Server for SPARC (also called Logical Domains) for availability. This series will show how to how to plan for availability, improve serviceability, avoid single points of failure, and provide resiliency against hardware and software failures. Availability is a broad topic that has filled entire books, so these posts will focus on aspects specifically related to Oracle VM Server for SPARC. The goal is to improve Reliability, Availability and Serviceability (RAS): An article defining RAS can be found here. Oracle VM Server for SPARC Principles for Availability Let's state some guiding principles for availability that apply to Oracle VM Server for SPARC: Avoid Single Points Of Failure (SPOFs). Systems should be configured so a component failure does not result in a loss of application service. The general method to avoid SPOFs is to provide redundancy so service can continue without interruption if a component fails. For a critical application there may be multiple levels of redundancy so multiple failures can be tolerated. Oracle VM Server for SPARC makes it possible to configure systems that avoid SPOFs. Configure for availability at a level of resource and effort consistent with business needs. Effort and resource should be consistent with business requirements. Production has different availability requirements than test/development, so it's worth expending resources to provide higher availability. Even within the category of production there may be different levels of criticality, outage tolerances, recovery and repair time requirements. Keep in mind that a simple design may be more understandable and effective than a complex design that attempts to "do everything". Design for availability at the appropriate tier or level of the platform stack. Availability can be provided in the application, in the database, or in the virtualization, hardware and network layers they depend on - or using a combination of all of them. It may not be necessary to engineer resilient virtualization for stateless web applications applications where availability is provided by a network load balancer, or for enterprise applications like Oracle Real Application Clusters (RAC) and WebLogic that provide their own resiliency. It's (often) the same architecture whether virtual or not: For example, providing resiliency against a lost device path or failing disk media is done for the same reasons and may use the same design whether in a domain or not. It's (often) the same technique whether using domains or not: Many configuration steps are the same. For example, configuring IPMP or creating a redundant ZFS pool is pretty much the same within the guest whether you're in a guest domain or not. There are configuration steps and choices for provisioning the guest with the virtual network and disk devices, which we will discuss. Sometimes it is different using domains: There are new resources to configure. Most notable is the use of alternate service domains, which provides resiliency in case of a domain failure, and also permits improved serviceability via "rolling upgrades". This is an important differentiator between Oracle VM Server for SPARC and traditional virtual machine environments where all virtual I/O is provided by a monolithic infrastructure that itself is a SPOF. Alternate service domains are widely used to provide resiliency in production logical domains environments. Some things are done via logical domains commands, and some are done in the guest: For example, with Oracle VM Server for SPARC we provide multiple network connections to the guest, and then configure network resiliency in the guest via IP Multi Pathing (IPMP) - essentially the same as for non-virtual systems. On the other hand, we configure virtual disk availability in the virtualization layer, and the guest sees an already-resilient disk without being aware of the details. These blogs will discuss configuration details like this. Live migration is not "high availability" in the sense of "continuous availability": If the server is down, then you don't live migrate from it! (A cluster or VM restart elsewhere would be used). However, live migration can be part of the RAS (Reliability, Availability, Serviceability) picture by improving Serviceability - you can move running domains off of a box before planned service or maintenance. The blog Best Practices - Live Migration on Oracle VM Server for SPARC discusses this. Topics Here are some of the topics that will be covered: Network availability using IP Multipathing and aggregates Disk path availability using virtual disks defined with multipath groups ("mpgroup") Disk media resiliency configuring for redundant disks that can tolerate media loss Multiple service domains - this is probably the most significant item and the one most specific to Oracle VM Server for SPARC. It is very widely deployed in production environments as the means to provide network and disk availability, but it can be confusing. Subsequent articles will describe why and how to configure multiple service domains. Note, for the sake of precision: an I/O domain is any domain that has a physical I/O resource (such as a PCIe bus root complex). A service domain is a domain providing virtual device services to other domains; it is almost always an I/O domain too (so it can have something to serve). Resources Here are some important links; we'll be drawing on their content in the next several articles: Oracle VM Server for SPARC Documentation Maximizing Application Reliability and Availability with SPARC T5 Servers whitepaper by Gary Combs Maximizing Application Reliability and Availability with the SPARC M5-32 Server whitepaper by Gary Combs Summary Oracle VM Server for SPARC offers features that can be used to provide highly-available environments. This and the following blog entries will describe how to plan and deploy them.

    Read the article

  • Is it possible to transfer a domain without a "gap" in Whois privacy protection?

    - by Guest
    I currently own several domains on which I am using a Whois privacy protection service to hide my personal details. In the near future, I would like to transfer some of these domains to a different registrar. It has been many years since I last performed domain transfers, so I am no longer knowledgeable about what it involves. However, I have read from several registrars that they ask their customers to disable Whois protection before effecting a domain transfer. Since there are several websites out there that publish archived versions of Whois information (and ask handsome money for the information to be hidden, of course), I would prefer to avoid having such a "gap" in my privacy protection. I figured that these websites would fetch Whois information mainly when a query is effected through their own website. However, I have found out that at least one of these sites had a copy of the Whois information for a new domain up on their site within hours after I registered it, so they must have some other source (of course I used a Google search to find that out, not their own site). What that tells me is that the time it takes for the domain transfers to go through would be more than enough for these rogue websites to cache my information. If my new registrar offers privacy protection for domains right from the point of registration as well, is there no way to transfer the domain between the two without reverting to my default Whois information in between?

    Read the article

  • Javascript hasOwnProperty does not work under Google Chrome

    - by WebRookie
    I am currently working with some help and it has been going well, until this incident. function runCommand(commandString) { commands = new Object(); commands.clear = function(){ $('#terminal').html('') } parameters = commandString.split(" "); command = parameters.shift(); if( commands.hasOwnProperty(command)){ commandscommand; } else { $('#terminal').append(command+' command not recognized.'+''); } } The person who was helping me made this function, so I could run the "terminal-like" browsers that I needed to work on. It works fine when using Firefox, heres an example: guest@shell:/$ sudo make me sandwich sudo command not recognized. guest@shell:/$ clear *clears* guest@shell:/$ clear But under google chrome this happen: guest@shell:/$ sudo make me sandwich sudo command not recognized. guest@shell:/$ clear clear command not recognized. I believe that it has something to do with "commands.hasOwnProperty(command)" that is preventing it from working properly. I am using JQuery the javascript library to build the website, and I need to know how to solve this problem, or an alternative.

    Read the article

  • The Design of the Namecheap Site [on hold]

    - by Guest
    I was just wondering what design Namecheap.com is using for their site. I asked their support personnel and I suppose the employees aren't generally aware. It really looks like a customized wordpress site, but I was wondering if anyone here knew any more details about their setup. Been googling for it but the problem is, since namecheap DEALS with CMS's/web design for their business, you'll get google hits regarding their business rather than describing their site itself. Just interested. If anyone's got any info on it let me know.

    Read the article

  • What's up with LDoms: Part 9 - Direct IO

    - by Stefan Hinker
    In the last article of this series, we discussed the most general of all physical IO options available for LDoms, root domains.  Now, let's have a short look at the next level of granularity: Virtualizing individual PCIe slots.  In the LDoms terminology, this feature is called "Direct IO" or DIO.  It is very similar to root domains, but instead of reassigning ownership of a complete root complex, it only moves a single PCIe slot or endpoint device to a different domain.  Let's look again at hardware available to mars in the original configuration: root@sun:~# ldm ls-io NAME TYPE BUS DOMAIN STATUS ---- ---- --- ------ ------ pci_0 BUS pci_0 primary pci_1 BUS pci_1 primary pci_2 BUS pci_2 primary pci_3 BUS pci_3 primary /SYS/MB/PCIE1 PCIE pci_0 primary EMP /SYS/MB/SASHBA0 PCIE pci_0 primary OCC /SYS/MB/NET0 PCIE pci_0 primary OCC /SYS/MB/PCIE5 PCIE pci_1 primary EMP /SYS/MB/PCIE6 PCIE pci_1 primary EMP /SYS/MB/PCIE7 PCIE pci_1 primary EMP /SYS/MB/PCIE2 PCIE pci_2 primary EMP /SYS/MB/PCIE3 PCIE pci_2 primary OCC /SYS/MB/PCIE4 PCIE pci_2 primary EMP /SYS/MB/PCIE8 PCIE pci_3 primary EMP /SYS/MB/SASHBA1 PCIE pci_3 primary OCC /SYS/MB/NET2 PCIE pci_3 primary OCC /SYS/MB/NET0/IOVNET.PF0 PF pci_0 primary /SYS/MB/NET0/IOVNET.PF1 PF pci_0 primary /SYS/MB/NET2/IOVNET.PF0 PF pci_3 primary /SYS/MB/NET2/IOVNET.PF1 PF pci_3 primary All of the "PCIE" type devices are available for SDIO, with a few limitations.  If the device is a slot, the card in that slot must support the DIO feature.  The documentation lists all such cards.  Moving a slot to a different domain works just like moving a PCI root complex.  Again, this is not a dynamic process and includes reboots of the affected domains.  The resulting configuration is nicely shown in a diagram in the Admin Guide: There are several important things to note and consider here: The domain receiving the slot/endpoint device turns into an IO domain in LDoms terminology, because it now owns some physical IO hardware. Solaris will create nodes for this hardware under /devices.  This includes entries for the virtual PCI root complex (pci_0 in the diagram) and anything between it and the actual endpoint device.  It is very important to understand that all of this PCIe infrastructure is virtual only!  Only the actual endpoint devices are true physical hardware. There is an implicit dependency between the guest owning the endpoint device and the root domain owning the real PCIe infrastructure: Only if the root domain is up and running, will the guest domain have access to the endpoint device. The root domain is still responsible for resetting and configuring the PCIe infrastructure (root complex, PCIe level configurations, error handling etc.) because it owns this part of the physical infrastructure. This also means that if the root domain needs to reset the PCIe root complex for any reason (typically a reboot of the root domain) it will reset and thus disrupt the operation of the endpoint device owned by the guest domain.  The result in the guest is not predictable.  I recommend to configure the resulting behaviour of the guest using domain dependencies as described in the Admin Guide in Chapter "Configuring Domain Dependencies". Please consult the Admin Guide in Section "Creating an I/O Domain by Assigning PCIe Endpoint Devices" for all the details! As you can see, there are several restrictions for this feature.  It was introduced in LDoms 2.0, mainly to allow the configuration of guest domains that need access to tape devices.  Today, with the higher number of PCIe root complexes and the availability of SR-IOV, the need to use this feature is declining.  I personally do not recommend to use it, mainly because of the drawbacks of the depencies on the root domain and because it can be replaced with SR-IOV (although then with similar limitations). This was a rather short entry, more for completeness.  I believe that DIO can usually be replaced by SR-IOV, which is much more flexible.  I will cover SR-IOV in the next section of this blog series.

    Read the article

  • SQL SERVER – Summary of Month – Wait Type – Day 28 of 28

    - by pinaldave
    I am glad to announce that the month of Wait Types and Queues very successful. I am glad that it was very well received and there was great amount of participation from community. I am fortunate to have some of the excellent comments throughout the series. I want to dedicate this series to all the guest blogger – Jonathan, Jacob, Glenn, and Feodor for their kindness to take a participation in this series. Here is the complete list of the blog posts in this series. I enjoyed writing the series and I plan to continue writing similar series. Please offer your opinion. SQL SERVER – Introduction to Wait Stats and Wait Types – Wait Type – Day 1 of 28 SQL SERVER – Signal Wait Time Introduction with Simple Example – Wait Type – Day 2 of 28 SQL SERVER – DMV – sys.dm_os_wait_stats Explanation – Wait Type – Day 3 of 28 SQL SERVER – DMV – sys.dm_os_waiting_tasks and sys.dm_exec_requests – Wait Type – Day 4 of 28 SQL SERVER – Capturing Wait Types and Wait Stats Information at Interval – Wait Type – Day 5 of 28 SQL SERVER – CXPACKET – Parallelism – Usual Solution – Wait Type – Day 6 of 28 SQL SERVER – CXPACKET – Parallelism – Advanced Solution – Wait Type – Day 7 of 28 SQL SERVER – SOS_SCHEDULER_YIELD – Wait Type – Day 8 of 28 SQL SERVER – PAGEIOLATCH_DT, PAGEIOLATCH_EX, PAGEIOLATCH_KP, PAGEIOLATCH_SH, PAGEIOLATCH_UP – Wait Type – Day 9 of 28 SQL SERVER – IO_COMPLETION – Wait Type – Day 10 of 28 SQL SERVER – ASYNC_IO_COMPLETION – Wait Type – Day 11 of 28 SQL SERVER – PAGELATCH_DT, PAGELATCH_EX, PAGELATCH_KP, PAGELATCH_SH, PAGELATCH_UP – Wait Type – Day 12 of 28 SQL SERVER – FT_IFTS_SCHEDULER_IDLE_WAIT – Full Text – Wait Type – Day 13 of 28 SQL SERVER – BACKUPIO, BACKUPBUFFER – Wait Type – Day 14 of 28 SQL SERVER – LCK_M_XXX – Wait Type – Day 15 of 28 SQL SERVER – Guest Post – Jonathan Kehayias – Wait Type – Day 16 of 28 SQL SERVER – WRITELOG – Wait Type – Day 17 of 28 SQL SERVER – LOGBUFFER – Wait Type – Day 18 of 28 SQL SERVER – PREEMPTIVE and Non-PREEMPTIVE – Wait Type – Day 19 of 28 SQL SERVER – MSQL_XP – Wait Type – Day 20 of 28 SQL SERVER – Guest Posts – Feodor Georgiev – The Context of Our Database Environment – Going Beyond the Internal SQL Server Waits – Wait Type – Day 21 of 28 SQL SERVER – Guest Post – Jacob Sebastian – Filestream – Wait Types – Wait Queues – Day 22 of 28 SQL SERVER – OLEDB – Link Server – Wait Type – Day 23 of 28 SQL SERVER – 2000 – DBCC SQLPERF(waitstats) – Wait Type – Day 24 of 28 SQL SERVER – 2011 – Wait Type – Day 25 of 28 SQL SERVER – Guest Post – Glenn Berry – Wait Type – Day 26 of 28 SQL SERVER – Best Reference – Wait Type – Day 27 of 28 SQL SERVER – Summary of Month – Wait Type – Day 28 of 28 Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, SQL, SQL Authority, SQL Optimization, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, SQL Wait Stats, SQL Wait Types, SQLServer, T SQL, Technology

    Read the article

  • "shutting down hyper-v virtual machine management service"

    - by icelava
    I have a Windows 2008 R2 server that is a Hyper-V host (Dell PowerEdge T300). Today for the first time I encountered an odd situation; i lost connection with one of the guest machines but logging on physically it seems the guest OS is still running but no longer contactable via the network. I tried to shut down the guest machine (Windows XP) but it would not shut down, getting stuck in a "Not responding" dialog box that cannot be dismissed. I used the Hyper-V management console to reset the machine and it could not get out of resetting state. I tried to save another Windows 2003 guest machine, and it would be progress with its Saving state (0%). The other running Windows 2003 guest was stuck in the logon dialog. My first suspicion is perhaps one of the Windows update patches this week (10 Nov 2011) may something to do with it, which was still pending a system restart. Well, since I could not do anything with Hyper-V i proceeded with the Windows Update restart, and now it is stuck half an hour at "Shutting down hyper-v virtual machine management service" Prior to restarting I did not observe any hard disk errors reported in the system event log; doubt it is a disk-related condition. Shall I force a hard reboot? UPDATE As per answer report, it eventually restarted itself.

    Read the article

  • vlan change via scvmm not working

    - by HarryMud
    Hi i have a windows 2008 R2 hyper-v server which is managed via scvmm 2008 R2. the guest os running on the hyper-v server is winxp with sp3. if i change the vlan id via scvmm the guest doesn't get an ip via dhcp i looked in the properties of the vm with the hyper-v mmc an see the vlan changed correctly but no ip connectivity either static or dhcp a reboot of the guest os didn't help if i change the vlan id via hyper-v mmc the guest gets an ip via dhcp scvmm seams to forget something after the vlan change has anyone a clue how to resolve this ? thx

    Read the article

  • Wireless AAA for a small, bandwidth-limited hotel.

    - by Anthony Hiscox
    We (the tech I work with and myself) live in a remote northern town where Internet access is somewhat of a luxury, and bandwidth is quite limited. Here, overage charges ranging from few hundreds, to few thousands of dollars a month, is not uncommon. I myself incur regular monthly charges just through my regular Internet usage at home (I am allowed 10G for $60CAD!) As part of my work, I have found myself involved with several hotels that are feeling this. I know that I can come up with something to solve this problem, but I am relatively new to system administration and I don't want my dreams to overcome reality. So, I pass these ideas on to you, those with much more experience than I, in hopes you will share some of your thoughts and concerns. This system must be cost effective, yes the charges are high here, but the trust in technology is the lowest I've ever seen. Must be capable of helping client reduce their usage (squid) Allow a limited (throughput and total usage) amount of free Internet, as this is often franchise policy. Allow a user to track their bandwidth usage Allow (optional) higher speed and/or usage for an additional charge. This fee can be obtained at the front desk on checkout and should not require the use of PayPal or Credit Card. Unfortunately some franchises have ridiculous policies that require the use of a third party remote service to authenticate guests to your network. This means WPA is out, and it also means that I do not auth before Internet usage, that will be their job. However, I do require the ABILITY to perform authentication for Internet access if a hotel does not have this policy. I will still have to track bandwidth (under a guest account by default) and provide the same limiting, however the guest often will require a complete 'unlimited' access, in terms of existence, not throughput. Provide firewalling capabilities for hotels that have nothing, Office, and Guest network segregation (some of these guys are running their office on the guest network, with no encryption, and a simple TOS to get on!) Prevent guests from connecting to other guests, however provide a means to allow this to happen. IE. Each guest connects to a page and allows the other guest, this writes a iptables rule (with python-netfilter) and allows two rooms to play a game, for instance. My thoughts on how to implement this. One decent box (we'll call it a router now) with a lot of ram, and 3 NIC's: Internet Office Guests (AP's + In Room Ethernet) Router Firewall Rules Guest can talk to router only, through which they are routed to where they need to go, including Internet services. Office can be used to bridge Office to Internet if an existing solution is not in place, otherwise, it simply works for a network accessible web (webmin+python-webmin?) interface. Router Software: OpenVZ provides virtualization for a few services I don't really trust. Squid, FreeRADIUS and Apache. The only service directly accessible to guests is Apache. Apache has mod_wsgi and django, because I can write quickly using django and my needs are low. It also potentially has the FreeRADIUS mod, but there seems to be some caveats with this. Firewall rules are handled on the router with iptables. Webmin (or a custom django app maybe) provides abstracted control over any features that the staff may need to access. Python, if you haven't guessed it's the language I feel most comfortable in, and I use it for almost everything. And finally, has this been done, is it a overly massive project not worth taking on for one guy, and/or is there some tools I'm missing that could be making my life easier? For the record, I am fairly good with Python, but not very familiar with many other languages (I can struggle through PHP, it's a cosmetic issue there). I am also an avid linux user, and comfortable with config files and command line. Thank you for your time, I look forward to reading your responses. Edit: My apologies if this is not a Q&A in the sense that some were expecting, I'm just looking for ideas and to make sure I'm not trying to do something that's been done. I'm looking at pfSense now as a possible start for what I need.

    Read the article

  • Virtualbox two networks slow

    - by Petr Marek
    I am running an Ubuntu server guest on Win 7 guest, and am running a webrick server (RoR dev). If I have just a host-only network, everything works fine and the browser response is instant. However, if I add a second network (NAT), so that the server can connect to the internet (for various updates etc.), the host-to-guest access gets really slow. I can't use the bridge connection. I am using the port 3000 (RoR Webrick server) and connecting to the guest via internet browser on this port (eg http://192.168.56.102:3000). Any idea, what could be causing this? If I ping the IP from host console, I get < 0ms. Here are the settings (relevant info is in english; Povoleno vše is Everything is allowed):

    Read the article

  • qemu-kvm virtual machine virtio network freeze under load

    - by Rick Koshi
    I'm having a problem with my virtual machines, where the network will freeze under heavy load. I'm using CentOS 6.2 as both host and guest, not using libvirt, just running qemu-kvm directly as follows: /usr/libexec/qemu-kvm \ -drive file=/data2/vm/rb-dev2-www1-vm.img,index=0,media=disk,cache=none,if=virtio \ -boot order=c \ -m 2G \ -smp cores=1,threads=2 \ -vga std \ -name rb-dev2-www1-vm \ -vnc :84,password \ -net nic,vlan=0,macaddr=52:54:20:00:00:54,model=virtio \ -net tap,vlan=0,ifname=tap84,script=/etc/qemu-ifup \ -monitor unix:/var/run/vm/rb-dev2-www1-vm.mon,server,nowait \ -rtc base=utc \ -device piix3-usb-uhci \ -device usb-tablet /etc/qemu-ifup (used by the above command) is a very simple script, containing the following: #!/bin/sh sudo /sbin/ifconfig $1 0.0.0.0 promisc up sudo /usr/sbin/brctl addif br0 $1 sleep 2 And here's the info on br0 and other interfaces: avl-host3 14# brctl show bridge name bridge id STP enabled interfaces br0 8000.180373f5521a no bond0 tap84 virbr0 8000.525400858961 yes virbr0-nic avl-host3 15# ip addr show 1: lo: <LOOPBACK,UP,LOWER_UP> mtu 16436 qdisc noqueue state UNKNOWN link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00 inet 127.0.0.1/8 scope host lo inet6 ::1/128 scope host valid_lft forever preferred_lft forever 2: em1: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master bond0 state UP qlen 1000 link/ether 18:03:73:f5:52:1a brd ff:ff:ff:ff:ff:ff 3: em2: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master bond0 state UP qlen 1000 link/ether 18:03:73:f5:52:1a brd ff:ff:ff:ff:ff:ff 4: em3: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN qlen 1000 link/ether 18:03:73:f5:52:1e brd ff:ff:ff:ff:ff:ff 5: em4: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN qlen 1000 link/ether 18:03:73:f5:52:20 brd ff:ff:ff:ff:ff:ff 6: bond0: <BROADCAST,MULTICAST,MASTER,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP link/ether 18:03:73:f5:52:1a brd ff:ff:ff:ff:ff:ff inet6 fe80::1a03:73ff:fef5:521a/64 scope link valid_lft forever preferred_lft forever 7: br0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UNKNOWN link/ether 18:03:73:f5:52:1a brd ff:ff:ff:ff:ff:ff inet 172.16.1.46/24 brd 172.16.1.255 scope global br0 inet6 fe80::1a03:73ff:fef5:521a/64 scope link valid_lft forever preferred_lft forever 8: virbr0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UNKNOWN link/ether 52:54:00:85:89:61 brd ff:ff:ff:ff:ff:ff inet 192.168.122.1/24 brd 192.168.122.255 scope global virbr0 9: virbr0-nic: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN qlen 500 link/ether 52:54:00:85:89:61 brd ff:ff:ff:ff:ff:ff 12: tap84: <BROADCAST,MULTICAST,PROMISC,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast state UNKNOWN qlen 500 link/ether ba:e8:9b:2a:ff:48 brd ff:ff:ff:ff:ff:ff inet6 fe80::b8e8:9bff:fe2a:ff48/64 scope link valid_lft forever preferred_lft forever bond0 is a bond of em1 and em2. virbr0 and virbr0-nic are vestigial interfaces left over from CentOS's default installation. They are unused (as far as I know). The guest runs perfectly until I run a large 'rsync', when the network will freeze after some seemingly-random time (usually under a minute). When it freezes, there is no network activity in or out of the guest. I can still connect to the guest's console via vnc, but it is unable to speak out its network interface. Any attempt to 'ping' from the guest gives a "Destination Host Unreachable" error for 3/4 packets and no reply for every fourth packet. Sometimes (perhaps two thirds of the time), I can bring the interface back to life by doing a "service network restart" from the guest's console. If this works (and if I do it before the rsync times out), the rsync will resume. Usually it will freeze again within a minute or two. If I repeat, the rsync will eventually finish, and I presume the machine goes back to waiting for another period of heavy load. Throughout the whole process, there are no console errors or relevant (that I can see) syslog messages on either guest or host machine. If the "service network restart" doesn't work the first time, trying again (and again and again) never seems to work. The command completes normally, with normal output, but the interface stays frozen. However, a soft reboot of the guest machine (without restarting qemu-kvm) always seems to bring it back. I am aware of the "lowest mac address" assignment problem, where the bridge takes on the mac address of the slave interface with the lowest mac address. This causes temporary network freezes, but is definitely not what's happening for me. My freezes are permanent until manual intervention, and you can see from the 'ip addr show' output above that the mac address being used by br0 is that of the physical ethernet. There are no other virtual machines running on the host. I've verified that each virtual machine on the subnet has its own unique mac address. I have rebuilt the guest machine several times, and I have tried this on three different host machines (identical hardware, built identically). Oddly, I do have one virtual host (the second of this series) which never seemed to have a problem. It never had its network freeze when it was running the same rsync during its build. It's particularly odd because it was the second build. The first, on a different host, did have the freezing problem, but the second did not. I assumed at the time that I had done something wrong with the first build, and that the problem was resolved. Unfortunately, the problem reappeared when I built the third VM. Also unfortunately, I can't do many tests with the working VM, as it's now in production use, and I'm hoping I can find the cause of this issue before that machine starts having problems. It's possible that I just got really lucky while running the rsync on the working machine, and that one time it didn't freeze. Of course it's possible that I somehow changed the build scripts without realizing it and re-broke something, but I can't find any such thing. In any case, I'm hoping someone has some idea what could cause this. Addendum: Preliminary tests suggest that I don't have the problem if I substitute e1000 for virtio in the first -net flag to qemu-kvm. I don't consider this a solution, but it is suitable for a stopgap. Has anyone else had (or better yet, solved) this problem with the virtio network driver?

    Read the article