Search Results

Search found 2436 results on 98 pages for 'verify'.

Page 24/98 | < Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >

  • Enable Automatic Code First Migrations On SQL Database in Azure Web Sites

    - by Steve Michelotti
    Now that Azure supports .NET Framework 4.5, you can use all the latest and greatest available features. A common scenario is to be able to use Entity Framework Code First Migrations with a SQL Database in Azure. Prior to Code First Migrations, Entity Framework provided database initializers. While convenient for demos and prototypes, database initializers weren’t useful for much beyond that because, if you delete and re-create your entire database when the schema changes, you lose all of your operational data. This is the void that Migrations are meant to fill. For example, if you add a column to your model, Migrations will alter the database to add the column rather than blowing away the entire database and re-creating it from scratch. Azure is becoming increasingly easier to use – especially with features like Azure Web Sites. Being able to use Entity Framework Migrations in Azure makes deployment easier than ever. In this blog post, I’ll walk through enabling Automatic Code First Migrations on Azure. I’ll use the Simple Membership provider for my example. First, we’ll create a new Azure Web site called “migrationstest” including creating a new SQL Database along with it:   Next we’ll go to the web site and download the publish profile:   In the meantime, we’ve created a new MVC 4 website in Visual Studio 2012 using the “Internet Application” template. This template is automatically configured to use the Simple Membership provider. We’ll do our initial Publish to Azure by right-clicking our project and selecting “Publish…”. From the “Publish Web” dialog, we’ll import the publish profile that we downloaded in the previous step:   Once the site is published, we’ll just click the “Register” link from the default site. Since the AccountController is decorated with the [InitializeSimpleMembership] attribute, the initializer will be called and the initial database is created.   We can verify this by connecting to our SQL Database on Azure with SQL Management Studio (after making sure that our local IP address is added to the list of Allowed IP Addresses in Azure): One interesting note is that these tables got created with the default Entity Framework initializer – which is to create the database if it doesn’t already exist. However, our database did already exist! This is because there is a new feature of Entity Framework 5 where Code First will add tables to an existing database as long as the target database doesn’t contain any of the tables from the model. At this point, it’s time to enable Migrations. We’ll open the Package Manger Console and execute the command: PM> Enable-Migrations -EnableAutomaticMigrations This will enable automatic migrations for our project. Because we used the "-EnableAutomaticMigrations” switch, it will create our Configuration class with a constructor that sets the AutomaticMigrationsEnabled property set to true: 1: public Configuration() 2: { 3: AutomaticMigrationsEnabled = true; 4: } We’ll now add our initial migration: PM> Add-Migration Initial This will create a migration class call “Initial” that contains the entire model. But we need to remove all of this code because our database already exists so we are just left with empty Up() and Down() methods. 1: public partial class Initial : DbMigration 2: { 3: public override void Up() 4: { 5: } 6: 7: public override void Down() 8: { 9: } 10: } If we don’t remove this code, we’ll get an exception the first time we attempt to run migrations that tells us: “There is already an object named 'UserProfile' in the database”. This blog post by Julie Lerman fully describes this scenario (i.e., enabling migrations on an existing database). Our next step is to add the Entity Framework initializer that will automatically use Migrations to update the database to the latest version. We will add these 2 lines of code to the Application_Start of the Global.asax: 1: Database.SetInitializer(new MigrateDatabaseToLatestVersion<UsersContext, Configuration>()); 2: new UsersContext().Database.Initialize(false); Note the Initialize() call will force the initializer to run if it has not been run before. At this point, we can publish again to make sure everything is still working as we are expecting. This time we’re going to specify in our publish profile that Code First Migrations should be executed:   Once we have re-published we can once again navigate to the Register page. At this point the database has not been changed but Migrations is now enabled on our SQL Database in Azure. We can now customize our model. Let’s add 2 new properties to the UserProfile class – Email and DateOfBirth: 1: [Table("UserProfile")] 2: public class UserProfile 3: { 4: [Key] 5: [DatabaseGeneratedAttribute(DatabaseGeneratedOption.Identity)] 6: public int UserId { get; set; } 7: public string UserName { get; set; } 8: public string Email { get; set; } 9: public DateTime DateOfBirth { get; set; } 10: } At this point all we need to do is simply re-publish. We’ll once again navigate to the Registration page and, because we had Automatic Migrations enabled, the database has been altered (*not* recreated) to add our 2 new columns. We can verify this by once again looking at SQL Management Studio:   Automatic Migrations provide a quick and easy way to keep your database in sync with your model without the worry of having to re-create your entire database and lose data. With Azure Web Sites you can set up automatic deployment with Git or TFS and automate the entire process to make it dead simple.

    Read the article

  • JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue

    - by John-Brown.Evans
    JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue ol{margin:0;padding:0} .c11_4{vertical-align:top;width:129.8pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c9_4{vertical-align:top;width:207pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt}.c14{vertical-align:top;width:207pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c17_4{vertical-align:top;width:129.8pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c7_4{vertical-align:top;width:130pt;border-style:solid;border-color:#000000;border-width:1pt;padding:0pt 5pt 0pt 5pt} .c19_4{vertical-align:top;width:468pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c22_4{background-color:#ffffff} .c20_4{list-style-type:disc;margin:0;padding:0} .c6_4{font-size:8pt;font-family:"Courier New"} .c24_4{color:inherit;text-decoration:inherit} .c23_4{color:#1155cc;text-decoration:underline} .c0_4{height:11pt;direction:ltr} .c10_4{font-size:10pt;font-family:"Courier New"} .c3_4{padding-left:0pt;margin-left:36pt} .c18_4{font-size:8pt} .c8_4{text-align:center} .c12_4{background-color:#ffff00} .c2_4{font-weight:bold} .c21_4{background-color:#00ff00} .c4_4{line-height:1.0} .c1_4{direction:ltr} .c15_4{background-color:#f3f3f3} .c13_4{font-family:"Courier New"} .c5_4{font-style:italic} .c16_4{border-collapse:collapse} .title{padding-top:24pt;line-height:1.15;text-align:left;color:#000000;font-size:36pt;font-family:"Arial";font-weight:bold;padding-bottom:6pt} .subtitle{padding-top:18pt;line-height:1.15;text-align:left;color:#666666;font-style:italic;font-size:24pt;font-family:"Georgia";padding-bottom:4pt} li{color:#000000;font-size:10pt;font-family:"Arial"} p{color:#000000;font-size:10pt;margin:0;font-family:"Arial"} h1{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h2{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:bold;padding-bottom:0pt} h3{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:14pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h4{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-style:italic;font-size:11pt;font-family:"Arial";padding-bottom:0pt} h5{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:10pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h6{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-style:italic;font-size:10pt;font-family:"Arial";padding-bottom:0pt} This post continues the series of JMS articles which demonstrate how to use JMS queues in a SOA context. The previous posts were: JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g JMS Step 2 - Using the QueueSend.java Sample Program to Send a Message to a JMS Queue JMS Step 3 - Using the QueueReceive.java Sample Program to Read a Message from a JMS Queue In this example we will create a BPEL process which will write (enqueue) a message to a JMS queue using a JMS adapter. The JMS adapter will enqueue the full XML payload to the queue. This sample will use the following WebLogic Server objects. The first two, the Connection Factory and JMS Queue, were created as part of the first blog post in this series, JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g. If you haven't created those objects yet, please see that post for details on how to do so. The Connection Pool will be created as part of this example. Object Name Type JNDI Name TestConnectionFactory Connection Factory jms/TestConnectionFactory TestJMSQueue JMS Queue jms/TestJMSQueue eis/wls/TestQueue Connection Pool eis/wls/TestQueue 1. Verify Connection Factory and JMS Queue As mentioned above, this example uses a WLS Connection Factory called TestConnectionFactory and a JMS queue TestJMSQueue. As these are prerequisites for this example, let us verify they exist. Log in to the WebLogic Server Administration Console. Select Services > JMS Modules > TestJMSModule You should see the following objects: If not, or if the TestJMSModule is missing, please see the abovementioned article and create these objects before continuing. 2. Create a JMS Adapter Connection Pool in WebLogic Server The BPEL process we are about to create uses a JMS adapter to write to the JMS queue. The JMS adapter is deployed to the WebLogic server and needs to be configured to include a connection pool which references the connection factory associated with the JMS queue. In the WebLogic Server Console Go to Deployments > Next and select (click on) the JmsAdapter Select Configuration > Outbound Connection Pools and expand oracle.tip.adapter.jms.IJmsConnectionFactory. This will display the list of connections configured for this adapter. For example, eis/aqjms/Queue, eis/aqjms/Topic etc. These JNDI names are actually quite confusing. We are expecting to configure a connection pool here, but the names refer to queues and topics. One would expect these to be called *ConnectionPool or *_CF or similar, but to conform to this nomenclature, we will call our entry eis/wls/TestQueue . This JNDI name is also the name we will use later, when creating a BPEL process to access this JMS queue! Select New, check the oracle.tip.adapter.jms.IJmsConnectionFactory check box and Next. Enter JNDI Name: eis/wls/TestQueue for the connection instance, then press Finish. Expand oracle.tip.adapter.jms.IJmsConnectionFactory again and select (click on) eis/wls/TestQueue The ConnectionFactoryLocation must point to the JNDI name of the connection factory associated with the JMS queue you will be writing to. In our example, this is the connection factory called TestConnectionFactory, with the JNDI name jms/TestConnectionFactory.( As a reminder, this connection factory is contained in the JMS Module called TestJMSModule, under Services > Messaging > JMS Modules > TestJMSModule which we verified at the beginning of this document. )Enter jms/TestConnectionFactory  into the Property Value field for Connection Factory Location. After entering it, you must press Return/Enter then Save for the value to be accepted. If your WebLogic server is running in Development mode, you should see the message that the changes have been activated and the deployment plan successfully updated. If not, then you will manually need to activate the changes in the WebLogic server console. Although the changes have been activated, the JmsAdapter needs to be redeployed in order for the changes to become effective. This should be confirmed by the message Remember to update your deployment to reflect the new plan when you are finished with your changes as can be seen in the following screen shot: The next step is to redeploy the JmsAdapter.Navigate back to the Deployments screen, either by selecting it in the left-hand navigation tree or by selecting the “Summary of Deployments” link in the breadcrumbs list at the top of the screen. Then select the checkbox next to JmsAdapter and press the Update button On the Update Application Assistant page, select “Redeploy this application using the following deployment files” and press Finish. After a few seconds you should get the message that the selected deployments were updated. The JMS adapter configuration is complete and it can now be used to access the JMS queue. To summarize: we have created a JMS adapter connection pool connector with the JNDI name jms/TestConnectionFactory. This is the JNDI name to be accessed by a process such as a BPEL process, when using the JMS adapter to access the previously created JMS queue with the JNDI name jms/TestJMSQueue. In the following step, we will set up a BPEL process to use this JMS adapter to write to the JMS queue. 3. Create a BPEL Composite with a JMS Adapter Partner Link This step requires that you have a valid Application Server Connection defined in JDeveloper, pointing to the application server on which you created the JMS Queue and Connection Factory. You can create this connection in JDeveloper under the Application Server Navigator. Give it any name and be sure to test the connection before completing it. This sample will use the connection name jbevans-lx-PS5, as that is the name of the connection pointing to my SOA PS5 installation. When using a JMS adapter from within a BPEL process, there are various configuration options, such as the operation type (consume message, produce message etc.), delivery mode and message type. One of these options is the choice of the format of the JMS message payload. This can be structured around an existing XSD, in which case the full XML element and tags are passed, or it can be opaque, meaning that the payload is sent as-is to the JMS adapter. In the case of an XSD-based message, the payload can simply be copied to the input variable of the JMS adapter. In the case of an opaque message, the JMS adapter’s input variable is of type base64binary. So the payload needs to be converted to base64 binary first. I will go into this in more detail in a later blog entry. This sample will pass a simple message to the adapter, based on the following simple XSD file, which consists of a single string element: stringPayload.xsd <?xml version="1.0" encoding="windows-1252" ?> <xsd:schema xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns="http://www.example.org" targetNamespace="http://www.example.org" elementFormDefault="qualified" <xsd:element name="exampleElement" type="xsd:string"> </xsd:element> </xsd:schema> The following steps are all executed in JDeveloper. The SOA project will be created inside a JDeveloper Application. If you do not already have an application to contain the project, you can create a new one via File > New > General > Generic Application. Give the application any name, for example JMSTests and, when prompted for a project name and type, call the project JmsAdapterWriteWithXsd and select SOA as the project technology type. If you already have an application, continue below. Create a SOA Project Create a new project and choose SOA Tier > SOA Project as its type. Name it JmsAdapterWriteSchema. When prompted for the composite type, choose Composite With BPEL Process. When prompted for the BPEL Process, name it JmsAdapterWriteSchema too and choose Synchronous BPEL Process as the template. This will create a composite with a BPEL process and an exposed SOAP service. Double-click the BPEL process to open and begin editing it. You should see a simple BPEL process with a Receive and Reply activity. As we created a default process without an XML schema, the input and output variables are simple strings. Create an XSD File An XSD file is required later to define the message format to be passed to the JMS adapter. In this step, we create a simple XSD file, containing a string variable and add it to the project. First select the xsd item in the left-hand navigation tree to ensure that the XSD file is created under that item. Select File > New > General > XML and choose XML Schema. Call it stringPayload.xsd and when the editor opens, select the Source view. then replace the contents with the contents of the stringPayload.xsd example above and save the file. You should see it under the xsd item in the navigation tree. Create a JMS Adapter Partner Link We will create the JMS adapter as a service at the composite level. If it is not already open, double-click the composite.xml file in the navigator to open it. From the Component Palette, drag a JMS adapter over onto the right-hand swim lane, under External References. This will start the JMS Adapter Configuration Wizard. Use the following entries: Service Name: JmsAdapterWrite Oracle Enterprise Messaging Service (OEMS): Oracle Weblogic JMS AppServer Connection: Use an existing application server connection pointing to the WebLogic server on which the above JMS queue and connection factory were created. You can use the “+” button to create a connection directly from the wizard, if you do not already have one. This example uses a connection called jbevans-lx-PS5. Adapter Interface > Interface: Define from operation and schema (specified later) Operation Type: Produce Message Operation Name: Produce_message Destination Name: Press the Browse button, select Destination Type: Queues, then press Search. Wait for the list to populate, then select the entry for TestJMSQueue , which is the queue created earlier. JNDI Name: The JNDI name to use for the JMS connection. This is probably the most important step in this exercise and the most common source of error. This is the JNDI name of the JMS adapter’s connection pool created in the WebLogic Server and which points to the connection factory. JDeveloper does not verify the value entered here. If you enter a wrong value, the JMS adapter won’t find the queue and you will get an error message at runtime, which is very difficult to trace. In our example, this is the value eis/wls/TestQueue . (See the earlier step on how to create a JMS Adapter Connection Pool in WebLogic Server for details.) MessagesURL: We will use the XSD file we created earlier, stringPayload.xsd to define the message format for the JMS adapter. Press the magnifying glass icon to search for schema files. Expand Project Schema Files > stringPayload.xsd and select exampleElement: string. Press Next and Finish, which will complete the JMS Adapter configuration. Wire the BPEL Component to the JMS Adapter In this step, we link the BPEL process/component to the JMS adapter. From the composite.xml editor, drag the right-arrow icon from the BPEL process to the JMS adapter’s in-arrow. This completes the steps at the composite level. 4. Complete the BPEL Process Design Invoke the JMS Adapter Open the BPEL component by double-clicking it in the design view of the composite.xml, or open it from the project navigator by selecting the JmsAdapterWriteSchema.bpel file. This will display the BPEL process in the design view. You should see the JmsAdapterWrite partner link under one of the two swim lanes. We want it in the right-hand swim lane. If JDeveloper displays it in the left-hand lane, right-click it and choose Display > Move To Opposite Swim Lane. An Invoke activity is required in order to invoke the JMS adapter. Drag an Invoke activity between the Receive and Reply activities. Drag the right-hand arrow from the Invoke activity to the JMS adapter partner link. This will open the Invoke editor. The correct default values are entered automatically and are fine for our purposes. We only need to define the input variable to use for the JMS adapter. By pressing the green “+” symbol, a variable of the correct type can be auto-generated, for example with the name Invoke1_Produce_Message_InputVariable. Press OK after creating the variable. ( For some reason, while I was testing this, the JMS Adapter moved back to the left-hand swim lane again after this step. There is no harm in leaving it there, but I find it easier to follow if it is in the right-hand lane, because I kind-of think of the message coming in on the left and being routed through the right. But you can follow your personal preference here.) Assign Variables Drag an Assign activity between the Receive and Invoke activities. We will simply copy the input variable to the JMS adapter and, for completion, so the process has an output to print, again to the process’s output variable. Double-click the Assign activity and create two Copy rules: for the first, drag Variables > inputVariable > payload > client:process > client:input_string to Invoke1_Produce_Message_InputVariable > body > ns2:exampleElement for the second, drag the same input variable to outputVariable > payload > client:processResponse > client:result This will create two copy rules, similar to the following: Press OK. This completes the BPEL and Composite design. 5. Compile and Deploy the Composite We won’t go into too much detail on how to compile and deploy. In JDeveloper, compile the process by pressing the Make or Rebuild icons or by right-clicking the project name in the navigator and selecting Make... or Rebuild... If the compilation is successful, deploy it to the SOA server connection defined earlier. (Right-click the project name in the navigator, select Deploy to Application Server, choose the application server connection, choose the partition on the server (usually default) and press Finish. You should see the message ---- Deployment finished. ---- in the Deployment frame, if the deployment was successful. 6. Test the Composite This is the exciting part. Open two tabs in your browser and log in to the WebLogic Administration Console in one tab and the Enterprise Manager 11g Fusion Middleware Control (EM) for your SOA installation in the other. We will use the Console to monitor the messages being written to the queue and the EM to execute the composite. In the Console, go to Services > Messaging > JMS Modules > TestJMSModule > TestJMSQueue > Monitoring. Note the number of messages under Messages Current. In the EM, go to SOA > soa-infra (soa_server1) > default (or wherever you deployed your composite to) and click on JmsAdapterWriteSchema [1.0], then press the Test button. Under Input Arguments, enter any string into the text input field for the payload, for example Test Message then press Test Web Service. If the instance is successful you should see the same text in the Response message, “Test Message”. In the Console, refresh the Monitoring screen to confirm a new message has been written to the queue. Check the checkbox and press Show Messages. Click on the newest message and view its contents. They should include the full XML of the entered payload. 7. Troubleshooting If you get an exception similar to the following at runtime ... BINDING.JCA-12510 JCA Resource Adapter location error. Unable to locate the JCA Resource Adapter via .jca binding file element The JCA Binding Component is unable to startup the Resource Adapter specified in the element: location='eis/wls/QueueTest'. The reason for this is most likely that either 1) the Resource Adapters RAR file has not been deployed successfully to the WebLogic Application server or 2) the '' element in weblogic-ra.xml has not been set to eis/wls/QueueTest. In the last case you will have to add a new WebLogic JCA connection factory (deploy a RAR). Please correct this and then restart the Application Server at oracle.integration.platform.blocks.adapter.fw.AdapterBindingException. createJndiLookupException(AdapterBindingException.java:130) at oracle.integration.platform.blocks.adapter.fw.jca.cci. JCAConnectionManager$JCAConnectionPool.createJCAConnectionFactory (JCAConnectionManager.java:1387) at oracle.integration.platform.blocks.adapter.fw.jca.cci. JCAConnectionManager$JCAConnectionPool.newPoolObject (JCAConnectionManager.java:1285) ... then this is very likely due to an incorrect JNDI name entered for the JMS Connection in the JMS Adapter Wizard. Recheck those steps. The error message prints the name of the JNDI name used. In this example, it was incorrectly entered as eis/wls/QueueTest instead of eis/wls/TestQueue. This concludes this example. Best regards John-Brown Evans Oracle Technology Proactive Support Delivery

    Read the article

  • Google Apps Email for new Primary Youtube Email

    - by MLM
    I have a YouTube account that I want to change the primary email for but every time I try to add a alternate address it says it is already associated with another google account. The email is a google apps user because I want to manage my domains email through gmail. I have already tried deleting the account and re-creating it to make sure it is not associated with anything. The only way I can add it is if I delete the google apps account but then I can not verify since I need to access the verification email.

    Read the article

  • What should be tested in Javascript?

    - by Nathan Hoad
    At work, we've just started on a heavily Javascript based application (actually using Coffeescript, but still), of which I've been implementing an automated test system using JsTestDriver and fabric. We've never written something with this much Javascript, so up until now we've never done any Javascript testing. I'm unsure what exactly we should be testing in our unit tests. We've written JQuery plugins for various things, so it's quite obvious that they should be verified for correctness as much as possible with JsTestDriver, but everyone else in my team seems to think that we should be testing the page level Javascript as well. I don't think we should be testing page level Javascript as unit tests, but instead using a system like Selenium to verify everything works as expected. My main reasoning for this is that at the moment, page level Javascript tests are guaranteed to fail through JsTestDriver, because they're trying to access elements on the DOM that can't possibly exist. So, what should be unit tested in Javascript?

    Read the article

  • How to fix “The requested service, ‘net.pipe://localhost/SecurityTokenServiceApplication/appsts.svc’ could not be activated.”

    - by ybbest
    Problem: When I try to publish a SharePoint2013 workflow, I received the error: The requested service, ‘net.pipe://localhost/SecurityTokenServiceApplication/appsts.svc’ could not be activated. After that, my workflow stopped working and every time I start a work I receive the following error message: System.ApplicationException: PreconditionFailed ---> System.ApplicationException: Error in the application. --- End of inner exception stack trace --- at System.Activities.Statements.Throw.Execute(CodeActivityContext context) at System.Activities.CodeActivity.InternalExecute(ActivityInstance instance, ActivityExecutor executor, BookmarkManager bookmarkManager) at System.Activities.Runtime.ActivityExecutor.ExecuteActivityWorkItem.ExecuteBody(ActivityExecutor executor, BookmarkManager bookmarkManager, Location resultLocation) Analysis: After analysis, I found the error by visiting the http://localhost:32843/SecurityTokenServiceApplication/securitytoken.svc and the error I got on the message is                                                                                                                                              Solution: The solution is basically getting more memory to the server. For development environment, you can restart your noderunner.exe or some other services to release some memories. To verify you have enough memory    you can browse to http://localhost:32843/SecurityTokenServiceApplication/securitytoken.svc , it should return the information below. Then you can republish your workflow and it will work like a charm.

    Read the article

  • "Virtual Machine Manager" and "Virtual Machine Server" setup manual

    - by urtihu
    Is there a manual available that covers the proper setup of a "Virtual Machine Server" with no GUI with an Ubuntu Workstation with a GUI and "Virtual Machine Manager" installed? Both are 12.04 version. I get the following error message: unable to connect to libvirt Verify that -The libvirt-bin package is installed -The libvirt daemon has been started -you are a member of the libvirtd group the package is installed for some reason starting the daemon seems to crash libvirtd start info: libvirt version 0.9.8 error: virExecWithHook:328 : cannot find 'pm-is-supported' in path: No such file or directory also qemucapsInit:856: Failed to get host power management capabilities So I guess I did not set the server up correctly. All manuals I found do not mention "Virtual Machine Manager". I only chose the packages to connect with SSH remotely and the "Virtual Machine Server" for the server installation. So I would like to find a manual that covers this combo or then covered only GUI machines that have both on the same machine, which will not really help with system performance as a hypervisor.

    Read the article

  • Juniper Strategy, LLC is hiring SharePoint Developers&hellip;

    - by Mark Rackley
    Isn’t everybody these days? It seems as though there are definitely more jobs than qualified devs these days, but yes, we are looking for a few good devs to help round out our burgeoning SharePoint team. Juniper Strategy is located in the DC area, however we will consider remote devs for the right fit. This is your chance to get in on the ground floor of a bright company that truly “gets it” when it comes to SharePoint, Project Management, and Information Assurance. We need like-minded people who “get it”, enjoy it, and who are looking for more than just a job. We have government and commercial opportunities as well as our own internal product that has a bright future of its own. Our immediate needs are for SharePoint .NET developers, but feel free to submit your resume for us to keep on file as it looks as though we’ll need several people in the coming months. Please email us your resume and salary requirements to [email protected] Below are our official job postings. Thanks for stopping by, we look forward to  hearing from you. Senior SharePoint .NET Developer Senior developer will focus on design and coding of custom, end-to-end business process solutions within the SharePoint framework. Senior developer with the ability to serve as a senior developer/mentor and manage day-to-day development tasks. Work with business consultants and clients to gather requirements to prepare business functional specifications. Analyze and recommend technical/development alternative paths based on business functional specifications. For selected development path, prepare technical specification and build the solution. Assist project manager with defining development task schedule and level-of-effort. Lead technical solution deployment. Job Requirements Minimum of 7 years experience in agile development, with at least 3 years of SharePoint-related development experience (SPS, SharePoint 2007/2010, WSS2-4). Thorough understanding of and demonstrated experience in development under the SharePoint Object Model, with focus on the WSS 3.0 foundation (MOSS 2007 Standard/Enterprise, Project Server 2007). Experience with using multiple data sources/repositories for database CRUD activities, including relational databases, SAP, Oracle e-Business. Experience with designing and deploying performance-based solutions in SharePoint for business processes that involve a very large number of records. Experience designing dynamic dashboards and mashups with data from multiple sources (internal to SharePoint as well as from external sources). Experience designing custom forms to facilitate user data entry, both with and without leveraging Forms Services. Experience building custom web part solutions. Experience with designing custom solutions for processing underlying business logic requirements including, but not limited to, SQL stored procedures, C#/ASP.Net workflows/event handlers (including timer jobs) to support multi-tiered decision trees and associated computations. Ability to create complex solution packages for deployment (e.g., feature-stapled site definitions). Must have impeccable communication skills, both written and verbal. Seeking a "tinkerer"; proactive with a thirst for knowledge (and a sense of humor). A US Citizen is required, and need to be able to pass NAC/E-Verify. An active Secret clearance is preferred. Applicants must pass a skills assessment test. MCP/MCTS or comparable certification preferred. Salary & Travel Negotiable SharePoint Project Lead Define project task schedule, work breakdown structure and level-of-effort. Serve as principal liaison to the customer to manage deliverables and expectations. Day-to-day project and team management, including preparation and maintenance of project plans, budgets, and status reports. Prepare technical briefings and presentation decks, provide briefs to C-level stakeholders. Work with business consultants and clients to gather requirements to prepare business functional specifications. Analyze and recommend technical/development alternative paths based on business functional specifications. The SharePoint Project Lead will be working with SharePoint architects and system owners to perform requirements/gap analysis and develop the underlying functional specifications. Once we have functional specifications as close to "final" as possible, the Project Lead will be responsible for preparation of the associated technical specification/development blueprint, along with assistance in preparing IV&V/test plan materials with support from other team members. This person will also be responsible for day-to-day management of "developers", but is also expected to engage in development directly as needed.  Job Requirements Minimum 8 years of technology project management across the software development life-cycle, with a minimum of 3 years of project management relating specifically to SharePoint (SPS 2003, SharePoint2007/2010) and/or Project Server. Thorough understanding of and demonstrated experience in development under the SharePoint Object Model, with focus on the WSS 3.0 foundation (MOSS 2007 Standard/Enterprise, Project Server 2007). Ability to interact and collaborate effectively with team members and stakeholders of different skill sets, personalities and needs. General "development" skill set required is a fundamental understanding of MOSS 2007 Enterprise, SP1/SP2, from the top-level of skinning to the core of the SharePoint object model. Impeccable communication skills, both written and verbal, and a sense of humor are required. The projects will require being at a client site at least 50% of the time in Washington DC (NW DC) and Maryland (near Suitland). A US Citizen is required, and need to be able to pass NAC/E-Verify. An active Secret clearance is preferred. PMP certification, PgMP preferred. Salary & Travel Negotiable

    Read the article

  • Get Your PhD in Googling [Slideshow]

    - by Asian Angel
    Think you know how to search Google with the best of them? Then put your knowledge to the test with this awesome slideshow where you can verify what you know and perhaps learn something new along the way. Note: The slideshow contains a total of 22 slides. Go Directly to the Slideshow Your PhD in Googling – Blog Post [via Geeks are Sexy] HTG Explains: What Is Two-Factor Authentication and Should I Be Using It? HTG Explains: What Is Windows RT and What Does It Mean To Me? HTG Explains: How Windows 8′s Secure Boot Feature Works & What It Means for Linux

    Read the article

  • Hiding an item conditionally through SPEL in OAF ( VO Extension + Personalization )

    - by Manoj Madhusoodanan
    In this blog I will explain how to conditionally set property of an item through personalization.Let me discuss using a business scenario. My customer wants to make Hold from Payment/ All Invoices column readonly when the Operating Unit is UK ( Configured in a lookup XXCUST_EXCLUDED_ORGS ). Analysis First thing is we have to find out the page and business components. Page: /oracle/apps/pos/supplier/webui/QuickUpdatePGView Object: oracle.apps.pos.supplier.server.SitesVO Solution Download oracle.apps.pos.supplier.server.SitesVO from $JAVA_TOP to JDEV_USER_HOME/myprojects.Make sure the transfer mode of the file (See below table). Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} File Type Transfer Mode .xml ASCII .class Binary .tar Binary .java ASCII  Since there is no VO attribute available to determine the Site Org against the lookup Org we have to add the logic inside a custom VO attribute. So VO extension is required in this scenario. Add an attribute "isPymtReadOnlyStr" in the existing query.This column returns 'Y' if there is a match in the lookup otherwise 'N'. Create a transient attribute "isPymtReadOnly" of type BOOLEAN.This will return TRUE if "isPymtReadOnlyStr" is "Y" otherwise FALSE. The reason behind adding the "isPymtReadOnly" is we are setting the item property as readonly through SPEL.It will recognize only BOOLEAN.But SQL query doesn't support BOOLEAN.So we are building a BOOLEAN attribute from the SQL which will use in the personalization layer to set the item property. Steps 1) Create a new VO xxcust.oracle.apps.pos.supplier.server.XXCUSTSitesVO which extends from oracle.apps.pos.supplier.server.SitesVO. Make sure the binding style should be same as SitesVO. Create the XXCUSTSitesVO which same query of SitesVO.Later we will add the new attribute to XXCUSTSitesVO. At this point of time all the existing VO attributes are of Updatable property as "Always". Press Finish without creating XXCUSTSitesVORowImpl.java 2) Select the XXCUSTSitesVO from JDeveloper Application Navigator. Modify the query and add the extra column. 3) Create a new transient attribute as follows. 4) Once you modify the query all the existing attributes Updatable property will change to Never.So revert that property back to orginal. 5) Create XXCUSTSitesVORowImpl.java by checking the following check box. 6) Add the following code snippet in XXCUSTSitesVORowImpl.java 7) Create the substitution for SitesVO as follows. Following entry will get created in current jpx file.    <Substitutes>      <Substitute OldName ="oracle.apps.pos.supplier.server.SitesVO" NewName ="xxcust.oracle.apps.pos.supplier.server.XXCUSTSitesVO" />   </Substitutes> 8) Migrate XXCUSTSitesVOImpl.java,XXCUSTSitesVORowImpl.java and XXCUSTSitesVO.xml from desktop to actual instance. 9) Migrate the substitution using jpximporter. 10) Restart the server and verify the substitution has done perfectly. 11) Go to /oracle/apps/pos/supplier/webui/QuickUpdatePG and personalize the page.Set the item read only property to ${oa.SitesVO.IsPymtReadOnly} 12) Click on Apply and in next page click on Return to Application. Verify your output.  Note: You can remove the substitution using following script.Please click here.

    Read the article

  • EPM 11.1.2 - In WebLogic Server, Enable Native IO Performance Pack

    - by Ahmed Awan
    Performance can be improved by enabling native IO in production mode. WebLogic Server benchmarks show major performance improvements when native performance packs are used on machines that host Oracle WebLogic Server instances. Important Note:  Always enable native I/O, if available, and check for errors at startup to make sure it is being initialed properly. Tip: The use of NATIVE performance packs are enabled by default in the configuration shipped with your distribution. You can use the Administration Console to verify that performance packs are enabled by clicking on each managed server and click on Tuning tab.

    Read the article

  • Passing the CAML thru the EY of the NEEDL

    - by PointsToShare
    © 2011 By: Dov Trietsch. All rights reserved Passing the CAML thru the EY of the NEEDL Definitions: CAML (Collaborative Application Markup Language) is an XML based markup language used in Microsoft SharePoint technologies  Anonymous: A camel is a horse designed by committee  Dov Trietsch: A CAML is a HORS designed by Microsoft  I was advised against putting any Camel and Sphinx rhymes in here. Look it up in Google!  _____ Now that we have dispensed with the dromedary jokes (BTW, I have many more, but they are not fit to print!), here is an interesting problem and its solution.  We have built a list where the title must be kept unique so I needed to verify the existence (or absence) of a list item with a particular title. Two methods came to mind:  1: Span the list until the title is found (result = found) or until the list ends (result = not found). This is an algorithm of complexity O(N) and for long lists it is a performance sucker. 2: Use a CAML query instead. Here, for short list we’ll encounter some overhead, but because the query results in an SQL query on the content database, it is of complexity O(LogN), which is significantly better and scales perfectly. Obviously I decided to go with the latter and this is where the CAML s--t hit the fan.   A CAML query returns a SPListItemCollection and I simply checked its Count. If it was 0, the item did not already exist and it was safe to add a new item with the given title. Otherwise I cancelled the operation and warned the user. The trouble was that I always got a positive. Most of the time a false positive. The count was greater than 0 regardles of the title I checked (except when the list was empty, which happens only once). This was very disturbing indeed. To solve my immediate problem which was speedy delivery, I reverted to the “Span the list” approach, but the problem bugged me, so I wrote a little console app by which I tested and tweaked and tested, time and again, until I found the solution. Yes, one can pass the proverbial CAML thru the ey of the needle (e’s missing on purpose).  So here are my conclusions:  CAML that does not work:  Note: QT is my quote:  char QT = Convert.ToChar((int)34); string titleQuery = "<Query>><Where><Eq>"; titleQuery += "<FieldRef Name=" + QT + "Title" + QT + "/>"; titleQuery += "<Value Type=" + QT + "Text" + QT + ">" + uniqueID + "</Value></Eq></Where></Query>"; titleQuery += "<ViewFields><FieldRef Name=" + QT + "Title" + QT + "/></ViewFields>";  Why? Even though U2U generates it, the <Query> and </Query> tags do not belong in the query that you pass. Start your query with the <Where> clause.  Also the <ViewFiels> clause does not belong. I used this clause to limit the returned collection to a single column, and I still wish to do it. I’ll show how this is done a bit later.   When you use the <Query> </Query> tags in you query, it’s as if you did not specify the query at all. What you get is the all inclusive default query for the list. It returns evey column and every item. It is expensive for both server and network because it does all the extra processing and eats plenty of bandwidth.   Now, here is the CAML that works  string titleQuery = "<Where><Eq>"; titleQuery += "<FieldRef Name=" + QT + "Title" + QT + "/>"; titleQuery += "<Value Type=" + QT + "Text" + QT + ">" + uniqueID + "</Value></Eq></Where>";  You’ll also notice that inside the unusable <ViewFields> clause above, we have a <FieldRef> clause. This is what we pass to the SPQuery object. Here is how:  SPQuery query = new SPQuery(); query.Query = titleQuery; query.ViewFields = "<FieldRef Name=" + QT + "Title" + QT + "/>"; query.RowLimit = 1; SPListItemCollection col = masterList.GetItems(query);  Two thing to note: we enter the view fields into the SPQuery object and we also limited the number of rows that the query returns. The latter is not always done, but in an existence test, there is no point in returning hundreds of rows. The query will now return one item or none, which is all we need in order to verify the existence (or non-existence) of items. Limiting the number of columns and the number of rows is a great performance enhancer. That’s all folks!!

    Read the article

  • Trash Destination Adapter

    The Trash Destination and this article came from early experiences of using SSIS and community feedback at the time. When developing a package it is very useful to have a destination adapter that does nothing but consume rows with no setup requirement. You often want run a package part way through development, or just add a path so you can set a Data Viewer. There are stock tasks that can be used, but with the Trash Destination all columns are treated as selected automatically (usage type of read-only), so the pipeline knows they are required. It is also obvious that this is for development or diagnostic purposes, and is clearly not a part of the functional design of the package. It is also ideal for just playing around and exploring concepts in SSIS, and is often used in conjunction with the Data Generator Source. Using these two components it is easy to setup a test of an expression in the Derived Column Transformation for example. The Data Generator Source provides some dummy data, and the Trash Destination allows you to anchor the output path and set a Data Viewer to examine the results. It can also be used when performance tuning packages. It is a consistent and known quantity that has no external influences, so it is ideal as a destination when breaking the data flow into sections to isolate a bottleneck. The adapter is really simple to use and requires no setup. Simply drop it onto the pipeline designer and use it to terminate your data flow path. Installation The component is provided as an MSI file which you can download and run to install it. This simply places the files on disk in the correct locations and also installs the assemblies in the Global Assembly Cache as per Microsoft’s recommendations. You may need to restart the SQL Server Integration Services service, as this caches information about what components are installed, as well as restarting any open instances of Business Intelligence Development Studio (BIDS) / Visual Studio that you may be using to build your SSIS packages. Finally, for 2005/2008, you will have to add the transformation to the Visual Studio toolbox manually. Right-click the toolbox, and select Choose Items.... Select the SSIS Data Flow Items tab, and then check the Trash Destination transformation in the Choose Toolbox Items window. This process has been described in detail in the related FAQ entry for How do I install a task or transform component? We recommend you follow best practice and apply the current Microsoft SQL Server Service pack to your SQL Server servers and workstations. Downloads The Trash Destination is available for SQL Server 2005, SQL Server 2008 (includes R2) and SQL Server 2012. Please choose the version to match your SQL Server version, or you can install multiple versions and use them side by side if you have more than one version of SQL Server installed. Trash Destination for SQL Server 2005 Trash Destination for SQL Server 2008 Trash Destination for SQL Server 2012 Version History SQL Server 2012 Version 3.0.0.34 - SQL Server 2012 release. Includes upgrade support for both 2005 and 2008 packages to 2012. (5 Jun 2012) SQL Server 2008 Version 2.0.0.33 - SQL Server 2008 release. Includes support for upgrade of 2005 packages. RTM compatible, previously February 2008 CTP. (4 Mar 2008) Version 2.0.0.31 - SQL Server 2008 November 2007 CTP. (14 Feb 2008) SQL Server 2005 Version 1.0.2.18 - SQL Server 2005 RTM Refresh. SP1 Compatibility Testing. (12 Jun 2006) Version 1.0.1.1 - SQL Server 2005 IDW 15 June CTP. Minor enhancements over v1.0.1.0. (11 Jun 2005) Version 1.0.1.0 - SQL Server 2005 IDW 14 April CTP. First Public Release. (30 May 2005) Troubleshooting Make sure you have downloaded the version that matches your version of SQL Server. We offer separate downloads for SQL Server 2005, SQL Server 2008 and SQL Server 2012. If you an error when you try and use the component along the lines of The component could not be added to the Data Flow task. Please verify that this component is properly installed.  ... The data flow object "Konesans ..." is not installed correctly on this computer, this usually indicates that the internal cache of SSIS components needs to be updated. This is held by the SSIS service, so you need restart the the SQL Server Integration Services service. You can do this from the Services applet in Control Panel or Administrative Tools in Windows. You can also restart the computer if you prefer. You may also need to restart any current instances of Business Intelligence Development Studio (BIDS) / Visual Studio that you may be using to build your SSIS packages. The full error message is shown below for reference: TITLE: Microsoft Visual Studio ------------------------------ The component could not be added to the Data Flow task. Please verify that this component is properly installed. ------------------------------ ADDITIONAL INFORMATION: The data flow object "Konesans.Dts.Pipeline.TrashDestination.Trash, Konesans.Dts.Pipeline.TrashDestination, Version=1.0.1.0, Culture=neutral, PublicKeyToken=b8351fe7752642cc" is not installed correctly on this computer. (Microsoft.DataTransformationServices.Design) For 2005/2008, once installation is complete you need to manually add the task to the toolbox before you will see it and to be able add it to packages - How do I install a task or transform component? This is not necessary for SQL Server 2012 as the new SSIS toolbox automatically detects components. If you are still having issues then contact us, but please provide as much detail as possible about error, as well as which version of the the task you are using and details of the SSIS tools installed.

    Read the article

  • Internal microphone not working in Google talk

    - by Tim
    My laptop is Lenovo T400, which has an internal microphone. My OS is Ubuntu 10.10. My browser is Firefox 11.0. The internal microphone works fine, because I can use it to record my voice using Audaciy. However, in Google talk, I have choose "Internal Audio Analog Stereo" in "Settings - Voice and video chat - Microphone:". But when I click "Verify your settings", it doesn't work. Neither can I speak to others using Google Talk. I wonder why? Thanks and regards!

    Read the article

  • Salt and hash a password in .NET

    - by Jon Canning
    I endeavoured to follow the CrackStation rules: Salted Password Hashing - Doing it Right    public class SaltedHash     {         public string Hash { get; private set; }         public string Salt { get; private set; }         public SaltedHash(string password)         {             var saltBytes = new byte[32];             new RNGCryptoServiceProvider().GetNonZeroBytes(saltBytes);             Salt = ConvertToBase64String(saltBytes);             var passwordAndSaltBytes = Concat(password, saltBytes);             Hash = ComputeHash(passwordAndSaltBytes);         }         static string ConvertToBase64String(byte[] bytes)         {             return Convert.ToBase64String(bytes);         }         static string ComputeHash(byte[] bytes)         {             return ConvertToBase64String(SHA256.Create().ComputeHash(bytes));         }         static byte[] Concat(string password, byte[] saltBytes)         {             var passwordBytes = Encoding.UTF8.GetBytes(password);             return passwordBytes.Concat(saltBytes).ToArray();         }         public static bool Verify(string salt, string hash, string password)         {             var saltBytes = Convert.FromBase64String(salt);             var passwordAndSaltBytes = Concat(password, saltBytes);             var hashAttempt = ComputeHash(passwordAndSaltBytes);             return hash == hashAttempt;         }     }

    Read the article

  • Writing the tests for FluentPath

    Writing the tests for FluentPath is a challenge. The library is a wrapper around a legacy API (System.IO) that wasnt designed to be easily testable. If it were more testable, the sensible testing methodology would be to tell System.IO to act against a mock file system, which would enable me to verify that my code is doing the expected file system operations without having to manipulate the actual, physical file system: what we are testing here is FluentPath, not System.IO. Unfortunately, that...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • BizTalk 2009 - Installing BizTalk Server 2009 on XP for Development

    - by StuartBrierley
    At my previous employer, when developing for BizTalk Server 2004 using Visual Studio 2003, we made use of separate development and deployment environments; developing in Visual Studio on our client PCs and then deploying to a seperate shared BizTalk 2004 Server from there.  This server was part of a multi-server Standard BizTalk environment comprising of separate BizTalk Server 2004 and SQL Server 2000 servers.  This environment was implemented a number of years ago by an outside consulting company, and while it worked it did occasionally cause contention issues with three developers deploying to the same server to carry out unit testing! Now that I am making the design and implementation decisions about the environment that BizTalk will be developed in and deployed to, I have chosen to create a single "server" installation on my development PC, installling SQL Server 2008, Visual Studio 2008 and BizTalk Server 2009 on a single system.  The client PC in use is actually a MacBook Pro running Windows XP; not the most powerful of systems for high volume processing but it should be powerful enough to allow development and initial unit testing to take place. I did not need to, and so chose not to, install all of the components detailed in the Microsoft guide for installing BizTalk 2009 on Windows XP but I did follow the basics of the procedures detailed within.  Outlined below are the highlights of this process and any details of what choices I made.   Install IIS I had previsouly installed Windows XP, including all current service packs and critical updates.  At the time of installation this included Service Pack 3, the .Net Framework 3.5 and MS Windows Installer 3.1.  Having a running XP system, my first step was to install IIS - this is quite straightforward and posed no difficulties. Install Visual Studio 2008 The next step for me was to install Visual Studio 2008.  Making sure to select a custom installation is crucial at this point, as you need to make sure that you deselect SQL Server 2005 Express Edition as it can cause the BizTalk installation to fail.  The installation guide suggests that you only select Visual C# when selecting features to install, but  I decided that due to some legacy systems I have code for that I would also select the VB and ASP options. Visual Studio 2008 Service Pack 1 Following the completion of the installation of Visual Studio itself you should then install the Visual Studio 2008 Service Pack 1. SQL Server 2008 Standard Edition The next step before intalling BizTalk Server 2009 itself is to install SQL Server 2008 Standard Edition. On the feature selection screen make sure that you select the follwoing options: Database Engine Services SQL Server Replication Full-Text Search Analysis Services Reporting Services Business Intelligence Development Studio Client Tools Connectivity Integration Services Management Tools Basic and Complete Use the default instance and the same accounts for all SQL server instances - in my case I used the Network Service and Local Service accounts for the two sets of accounts. On the database engine configuration screen I selected windows authentication and added the current user, adding the same user again on the Analysis services Configuration screen.  All other screens were left on the default settings. The SQL Server 2008 installation also included the installation of hotfix for XP KB942288-v3, the Windows Installer 4.5 Redistributable. System Configuration At this stage I took a moment to disable the SQL Server shared memory protocol and enable the Named Pipes and TCP/IP protocols.  These can be found in the SQL Server Configuration Manager > SQL Server Network Configuration > Protocols for MSSQLServer.  I also made sure that the DTC settings were configured correctley.   BizTalk Server 2009 The penultimate step is to install BizTalk Server 2009 Standard Edition. I had previsouly downloaded the redistributable prerequisites as a CAB file so was able to make use of this when carrying out the installation. When selecting which components to install I selected: Server Runtime BizTalk EDI/AS2 Runtime WCF Adapter Runtime Portal Components Administrative Tools WFC Administartion Tools Developer Tools and SDK, Enterprise SSO Administration Module Enterprise SSO Master Secret Server Business Rules Components BAM Alert Provider BAM Client BAM Eventing Once installation has completed clear the launch BizTalk Server Configuration check box and select finish. Verify the Installation Before configuring BizTalk Server it is a good idea to check that BizTalk Server 2009 is installed and that SQL Server 2008 has started correctly.  The easiest way to verify the BizTalk installation is check the Programs and Features in Control panel.  Check that SQL is started by looking in the SQL Server Configuration Manager. Configure BizTalk Server 2009 Finally we are ready to configure BizTalk Server 2009.  To start this I opted for a custom configuration that allowed me to choose in more detail the settings to be used. For all databases I selected the local server and default database names. For all Accounts I used a local account that had been created specifically for the BizTalk Services. For all windows groups I allowed the configuration wizard to create the default local groups. The configuration wizard then ran:   Upon completion you will be presented with a screen detailing the success or failure of the configuration.  If your configuration failed you will need to sort out the issues and try again (it is possible to save the configuration settings for later use if you want too - except passwords of course!).  If you see lots of nice green ticks - congratulations BizTalk Server 2009 on XP is now installed and configured ready for development.

    Read the article

  • GlassFish Clustering with DCOM on Windows

    - by ByronNevins
    DCOM - Distributed COM, a Microsoft protocol for communicating with Windows machines. Why use DCOM? In GlassFish 3.1 SSH is used as the standard way to run commands on remote nodes for clustering.  It is very difficult for users to get SSH configured properly on Windows.  SSH does not come with Windows so we have to depend on third party tools.  And then the user is forced to install and configure these tools -- which can be tricky. DCOM is available on all supported platforms.  It is built-in to Windows. The idea is to use DCOM to communicate with remote Windows nodes.  This has the huge advantage that the user has to do minimal, if any, configuration on the Windows nodes. Implementation HighlightsTwo open Source Libraries have been added to GlassFish: Jcifs – a SAMBA implementation in Java J-interop – A Java implementation for making DCOM calls to remote Windows computers.   Note that any supported platform can use DCOM to work with Windows nodes -- not just Windows.E.g. you can have a Linux DAS work with Windows remote instances.All existing SSH commands now have a corresponding DCOM command – except for setup-ssh which isn’t needed for DCOM.  validate-dcom is an all new command. New DCOM Commands create-node-dcom delete-node-dcom install-node-dcom list-nodes-dcom ping-node-dcom uninstall-node-dcom update-node-dcom validate-dcom setup-local-dcom (This is only available via Update Center for GlassFish 3.1.2) These commands are in-place in the trunk (4.0).  And in the branch (3.1.2) Windows Configuration Challenges There are an infinite number of possible configurations of Windows if you look at it as a combination of main release, service-pack, special drivers, software, configuration etc.  Later versions of Windows err on the side of tightening security be default.  This means that the Windows host may need to have configuration changes made.These configuration changes mostly need to be made by the user.  setup-local-dcom will assist you in making required changes to the Windows Registry.  See the reference blogs for details. The validate-dcom Command validate-dcom is a crucial command.  It should be run before any other commands.  If it does not run successfully then there is no point in running other commands.The validate-dcom command must be used from a DAS machine to test a different Windows machine.  If  validate-dcom runs successfully you can be confident that all the DCOM commands will work.  Conversely, the opposite is also true:  If validate-dcom fails, then no DCOM commands will work. What validate-dcom does Verify that the remote host is not the local machine. Resolves the remote host name Checks that the remote DCOM port is being listened on (135, 139) Checks that the remote host’s File Sharing is enabled (port 445) It copies a file (a script) to the remote host to verify that SAMBA is working and authorization is correct It runs a script that it copied on-the-fly to the remote host. Tips and Tricks The bread and butter commands that use DCOM are existing commands like create-instance, start-instance etc.   All of the commands that have dcom in their name are for dealing with the actual nodes. The way the software works is to call asadmin.bat on the remote machine and run a command.  This means that you can track these commands easily on the remote machine with the usual tools.  E.g. using AS_LOGFILE, looking at log files, etc.  It’s easy to attach a debugger to the remote asadmin process, “just in time”, if necessary. How to debug the remote commands:Edit the asadmin.bat file that is in the glassfish/bin folder.  Use glassfish/lib/nadmin.bat in GlassFish 4.0+Add these options to the java call:-Xdebug -Xrunjdwp:transport=dt_socket,server=y,suspend=y,address=1234  Now if you run, say start-instance on DAS, you can attach your debugger, at your leisure, to the remote machines port 1234.  It will be running start-local-instance and patiently waiting for you to attach.

    Read the article

  • DNS question and Google PageRank from domains

    - by Beck
    I'm not so good at dns at all :) Just basics. A while ago i have noticed, that my blog have different Page Ranks, PR 3 for domain www.example.com and PR 1 for domain example.com. In dns records i have this setup: A - IP - www.example.com A - same IP - example.com Should i replace this record "A - same IP - example.com" with row with CNAME instead of A? Like that: CNAME - same IP - example.com - alias www.example.com Will this combine Page Rank value of both domains? Or i can just create 302 redirection inside .htaccess file, verify example.com(without www) inside Google Webmaster Tools as my domain and inside www.example.com options set as main domain? Thanks ;)

    Read the article

  • Is it true that the Google Spider gives the most relevance of a search result to the first 68 characters of the <title>?

    - by leeand00
    I am reading documentation about my CMS and it states that an HTML page <title> tag is really important in SEO. It states that the Google Spider gives the most relevance to the first 68 characters of a site title. (68 characters being the number of characters that Google will display in it's search engine result pages,) Can anyone verify this is still true? I read in The Information Diet that content farms were getting too good at gaming Google's algorithm for collecting and posting SERPs and so google had to change the search algorithm.

    Read the article

  • Theoretically bug-free programs

    - by user2443423
    I have read lot of articles which state that code can't be bug-free, and they are talking about these theorems: Halting problem Gödel's incompleteness theorem Rice's theorem Actually Rice's theorem looks like an implication of the halting problem and the halting problem is in close relationship with Gödel's incompleteness theorem. Does this imply that every program will have at least one unintended behavior? Or does it mean that it's not possible to write code to verify it? What about recursive checking? Let's assume that I have two programs. Both of them have bugs, but they don't share the same bug. What will happen if I run them concurrently? And of course most of discussions talked about Turing machines. What about linear-bounded automation (real computers)?

    Read the article

  • How do I enable Flash 11.2 in Chrome?

    - by austen
    I'm trying to force Chrome to use Flash 11.2 rather than the packaged Pepper version because it doesn't support DRM and I want to be able to use Amazon Instant Video/HBO GO. I followed Adobe's instructions to a tee but when I restart Chrome and view the plugins, the Pepper flash version is still the only one available. I have expanded the details and am certain I have not just missed the other version. I checked the directories where the files were being copied to verify that it worked and it appears that they successfully copied without issue. Unfortunately, since I didn't run into any problems until finding that it just didn't work, I don't have many other details that might help shed some light on this. I'm crossing my fingers though and hoping that someone else might have had some experience with this. Thanks in advance. Version Info Ubuntu - 14.04 Chrome - 35.0.1916.114 Flash I'm trying to install - 11.2.202.359 Flash packaged with Chrome (Pepper) - 13.0.0.214

    Read the article

  • Correct DB details produce “Database server was not found” (Prestashop Installation)

    - by Steve
    At stage 3 of the Prestashop Installation, I enter the DB details which I know to be correct, and I receive the error: Database server was not found. Please verify the login, password, and database server name fields. The server is localhost, and I have verified the database name and username. Why can Prestashop not find the server? This occurs when choosing InnoDB and MyIsam. If I change the server from localhost to the public hostname I receive the same error.

    Read the article

  • lock screen before hibernating [12.04]

    - by Emanuel Ey
    So when i hibernate my laptop the screen doesn't lock automatically. To solve this if changed /etc/acpi/powerbtn.sh to contain: su - myUsername -c "gnome-screensaver-command -l" sudo pm-hibernate exit 0 When running this file from a command line it works as intended (ie, lock the screen and then hibernate). Unfortunately, when pressing the power button, it still just hibernates without locking the screen -what am I missing? EDIT: I've added the line whoami>>~/Desktop/test.txt to verify which user is executing the /etc/acpi/powerbtn.shscript. When pressing the power button, the file test.txt is created, but is empty. From this i conclude that the script is in fact being called when pressing the power button. What i do not understand is how the output of whoami can be empty...

    Read the article

  • How should programmers handle email-username identity theft?

    - by Craige
    Background I recently signed up for an iTunes account, and found that somebody had fraudulently used MY email to register their iTunes account. Why Apple did not validate the email address, I will never know. Now I am told that I cannot use my email address to register a new iTunes account, as this email address is linked to an existing account. This got be thinking... Question How should we as developers handle email/identity theft? Obviously, we should verify that an email address belongs to the person it is said to belong to. Why Apple did not do this in my case, I have no idea. But lets pretend we use email address for login/account identification, and something slipped though the cracks (be it our end, or the users). How should we handle reports of fraudulent accounts?

    Read the article

  • Ubuntu 11.10 doesn't detect Intel integrated graphics (i7-2670QM CPU)

    - by Telmo Marques
    The laptop I'm using is an MSI GT683DX-847PT that comes with an NVIDIA GeForce GTX570M discrete GPU, and an Intel Core i7-2670QM CPU. According to Intel's description of the Core i7-2670QM CPU, it has an HD Graphics 3000 integrated GPU. The problem is that the Intel integrated graphics GPU doesn't come up in lspci nor in lshw, only the NVIDIA GPU shows up. Here is the output of both commands: sudo lspci: http://pastebin.com/raw.php?i=9AZg8bJy sudo lshw: http://pastebin.com/raw.php?i=6cAMFQsY I was counting on having two GPU's to run CUDA programs on the discrete NVIDIA GPU, while X was handled by the integrated Intel GPU, to prevent kernel execution timeout. Why doesn't the Intel HD Graphics 3000 GPU show up? Any tests I could make to verify the presence of an integrated GPU?

    Read the article

< Previous Page | 20 21 22 23 24 25 26 27 28 29 30 31  | Next Page >