Search Results

Search found 14122 results on 565 pages for 'cable management'.

Page 240/565 | < Previous Page | 236 237 238 239 240 241 242 243 244 245 246 247  | Next Page >

  • Proving What You are Worth

    - by Ted Henson
    Here is a challenge for everyone. Just about everyone has been asked to provide or calculate the Return on Investment (ROI), so I will assume everyone has a method they use. The problem with stopping once you have an ROI is that those in the C-Suite probably do not care about the ROI as much as Return on Equity (ROE). Shareholders are mostly concerned with their return on the money the invested. Warren Buffett looks at ROE when deciding whether to make a deal or not. This article will outline how you can add more meaning to your ROI and show how you can potentially enhance the ROE of the company.   First I want to start with a base definition I am using for ROI and ROE. Return on investment (ROI) and return on equity (ROE) are ways to measure management effectiveness, parts of a system of measures that also includes profit margins for profitability, price-to-earnings ratio for valuation, and various debt-to-equity ratios for financial strength. Without a set of evaluation metrics, a company's financial performance cannot be fully examined by investors. ROI and ROE calculate the rate of return on a specific investment and the equity capital respectively, assessing how efficient financial resources have been used. Typically, the best way to improve financial efficiency is to reduce production cost, so that will be the focus. Now that the challenge has been made and items have been defined, let’s go deeper. Most research about implementation stops short at system start-up and seldom addresses post-implementation issues. However, we know implementation is a continuous improvement effort, and continued efforts after system start-up will influence the ultimate success of a system.   Most UPK ROI’s I have seen only include the cost savings in developing the training material. Some will also include savings based on reduced Help Desk calls. Using just those values you get a good ROI. To get an ROE you need to go a little deeper. Typically, the best way to improve financial efficiency is to reduce production cost, which is the purpose of implementing/upgrading an enterprise application. Let’s assume the new system is up and running and all users have been properly trained and are comfortable using the system. You provide senior management with your ROI that justifies the original cost. What you want to do now is develop a good base value to a measure the current efficiency. Using usage tracking you can look for various patterns. For example, you may find that users that are accessing UPK assistance are processing a procedure, such as entering an order, 5 minutes faster than those that don’t.  You do some research and discover each minute saved in processing a claim saves the company one dollar. That translates to the company saving five dollars on every transaction. Assuming 100,000 transactions are performed a year, and all users improve their performance, the company will be saving $500,000 a year. That $500,000 can be re-invested, used to reduce debt or paid to the shareholders.   With continued refinement during the life cycle, you should be able to find ways to reduce cost. These are the type of numbers and productivity gains that senior management and shareholders want to see. Being able to quantify savings and increase productivity may also help when seeking a raise or promotion.

    Read the article

  • Thinking Local, Regional and Global

    - by Apeksha Singh-Oracle
    The FIFA World Cup tournament is the biggest single-sport competition: it’s watched by about 1 billion people around the world. Every four years each national team’s manager is challenged to pull together a group players who ply their trade across the globe. For example, of the 23 members of Brazil’s national team, only four actually play for Brazilian teams, and the rest play in England, France, Germany, Spain, Italy and Ukraine. Each country’s national league, each team and each coach has a unique style. Getting all these “localized” players to work together successfully as one unit is no easy feat. In addition to $35 million in prize money, much is at stake – not least national pride and global bragging rights until the next World Cup in four years time. Achieving economic integration in the ASEAN region by 2015 is a bit like trying to create the next World Cup champion by 2018. The team comprises Brunei Darussalam, Cambodia, Indonesia, Lao PDR, Malaysia, Myanmar, Philippines, Singapore, Thailand and Vietnam. All have different languages, currencies, cultures and customs, rules and regulations. But if they can pull together as one unit, the opportunity is not only great for business and the economy, but it’s also a source of regional pride. BCG expects by 2020 the number of firms headquartered in Asia with revenue exceeding $1 billion will double to more than 5,000. Their trade in the region and with the world is forecast to increase to 37% of an estimated $37 trillion of global commerce by 2020 from 30% in 2010. Banks offering transactional banking services to the emerging market place need to prepare to repond to customer needs across the spectrum – MSMEs, SMEs, corporates and multi national corporations. Customers want innovative, differentiated, value added products and services that provide: • Pan regional operational independence while enabling single source of truth at a regional level • Regional connectivity and Cash & Liquidity  optimization • Enabling Consistent experience for their customers  by offering standardized products & services across all ASEAN countries • Multi-channel & self service capabilities / access to real-time information on liquidity and cash flows • Convergence of cash management with supply chain and trade finance While enabling the above to meet customer demands, the need for a comprehensive and robust credit management solution for effective regional banking operations is a must to manage risk. According to BCG, Asia-Pacific wholesale transaction-banking revenues are expected to triple to $139 billion by 2022 from $46 billion in 2012. To take advantage of the trend, banks will have to manage and maximize their own growth opportunities, compete on a broader scale, manage the complexity within the region and increase efficiency. They’ll also have to choose the right operating model and regional IT platform to offer: • Account Services • Cash & Liquidity Management • Trade Services & Supply Chain Financing • Payments • Securities services • Credit and Lending • Treasury services The core platform should be able to balance global needs and local nuances. Certain functions need to be performed at a regional level, while others need to be performed on a country level. Financial reporting and regulatory compliance are a case in point. The ASEAN Economic Community is in the final lap of its preparations for the ultimate challenge: becoming a formidable team in the global league. Meanwhile, transaction banks are designing their own hat trick: implementing a world-class IT platform, positioning themselves to repond to customer needs and establishing a foundation for revenue generation for years to come. Anand Ramachandran Senior Director, Global Banking Solutions Practice Oracle Financial Services Global Business Unit

    Read the article

  • When should I use a Process Model versus a Use Case?

    - by Dave Burke
    This Blog entry is a follow on to https://blogs.oracle.com/oum/entry/oum_is_business_process_and and addresses a question I sometimes get asked…..i.e. “when I am gathering requirements on a Project, should I use a Process Modeling approach, or should I use a Use Case approach?” Not surprisingly, the short answer is “it depends”! Let’s take a scenario where you are working on a Sales Force Automation project. We’ll call the process that is being implemented “Lead-to-Order”. I would typically think of this type of project as being “Process Centric”. In other words, the focus will be on orchestrating a series of human and system related tasks that ultimately deliver value to the business in a cost effective way. Put in even simpler terms……implement an automated pre-sales system. For this type of (Process Centric) project, requirements would typically be gathered through a series of Workshops where the focal point will be on creating, or confirming, the Future-State (To-Be) business process. If pre-defined “best-practice” business process models exist, then of course they could and should be used during the Workshops, but even in their absence, the focus of the Workshops will be to define the optimum series of Tasks, their connections, sequence, and dependencies that will ultimately reflect a business process that meets the needs of the business. Now let’s take another scenario. Assume you are working on a Content Management project that involves automating the creation and management of content for User Manuals, Web Sites, Social Media publications etc. Would you call this type of project “Process Centric”?.......well you could, but it might also fall into the category of complex configuration, plus some custom extensions to a standard software application (COTS). For this type of project it would certainly be worth considering using a Use Case approach in order to 1) understand the requirements, and 2) to capture the functional requirements of the custom extensions. At this point you might be asking “why couldn’t I use a Process Modeling approach for my Content Management project?” Well, of course you could, but you just need to think about which approach is the most effective. Start by analyzing the types of Tasks that will eventually be automated by the system, for example: Best Suited To? Task Name Process Model Use Case Notes Manage outbound calls Ö A series of linked human and system tasks for calling and following up with prospects Manage content revision Ö Updating the content on a website Update User Preferences Ö Updating a users display preferences Assign Lead Ö Reviewing a lead, then assigning it to a sales person Convert Lead to Quote Ö Updating the status of a lead, and then converting it to a sales order As you can see, it’s not an exact science, and either approach is viable for the Tasks listed above. However, where you have a series of interconnected Tasks or Activities, than when combined, deliver value to the business, then that would be a good indicator to lead with a Process Modeling approach. On the other hand, when the Tasks or Activities in question are more isolated and/or do not cross traditional departmental boundaries, then a Use Case approach might be worth considering. Now let’s take one final scenario….. As you captured the To-Be Process flows for the Sales Force automation project, you discover a “Gap” in terms of what the client requires, and what the standard COTS application can provide. Let’s assume that the only way forward is to develop a Custom Extension. This would now be a perfect opportunity to document the functional requirements (behind the Gap) using a Use Case approach. After all, we will be developing some new software, and one of the most effective ways to begin the Software Development Lifecycle is to follow a Use Case approach. As always, your comments are most welcome.

    Read the article

  • Webcast On-Demand: Building Java EE Apps That Scale

    - by jeckels
    With some awesome work by one of our architects, Randy Stafford, we recently completed a webcast on scaling Java EE apps efficiently. Did you miss it? No problem. We have a replay available on-demand for you. Just hit the '+' sign drop-down for access.Topics include: Domain object caching Service response caching Session state caching JSR-107 HotCache and more! Further, we had several interesting questions asked by our audience, and we thought we'd share a sampling of those here for you - just in case you had the same queries yourself. Enjoy! What is the largest Coherence deployment out there? We have seen deployments with over 500 JVMs in the Coherence cluster, and deployments with over 1000 JVMs using the Coherence jar file, in one system. On the management side there is an ecosystem of monitoring tools from Oracle and third parties with dashboards graphing values from Coherence's JMX instrumentation. For lifecycle management we have seen a lot of custom scripting over the years, but we've also integrated closely with WebLogic to leverage its management ecosystem for deploying Coherence-based applications and managing process life cycles. That integration introduces a new Java EE archive type, the Grid Archive or GAR, which embeds in an EAR and can be seen by a WAR in WebLogic. That integration also doesn't require any extra WebLogic licensing if Coherence is licensed. How is Coherence different from a NoSQL Database like MongoDB? Coherence can be considered a NoSQL technology. It pre-dates the NoSQL movement, having been first released in 2001 whereas the term "NoSQL" was coined in 2009. Coherence has a key-value data model primarily but can also be used for document data models. Coherence manages data in memory currently, though disk persistence is in a future release currently in beta testing. Where the data is managed yields a few differences from the most well-known NoSQL products: access latency is faster with Coherence, though well-known NoSQL databases can manage more data. Coherence also has features that well-known NoSQL database lack, such as grid computing, eventing, and data source integration. Finally Coherence has had 15 years of maturation and hardening from usage in mission-critical systems across a variety of industries, particularly financial services. Can I use Coherence for local caching? Yes, you get additional features beyond just a java.util.Map: you get expiration capabilities, size-limitation capabilities, eventing capabilites, etc. Are there APIs available for GoldenGate HotCache? It's mostly a black box. You configure it, and it just puts objects into your caches. However you can treat it as a glass box, and use Coherence event interceptors to enhance its behavior - and there are use cases for that. Are Coherence caches updated transactionally? Coherence provides several mechanisms for concurrency control. If a project insists on full-blown JTA / XA distributed transactions, Coherence caches can participate as resources. But nobody does that because it's a performance and scalability anti-pattern. At finer granularity, Coherence guarantees strict ordering of all operations (reads and writes) against a single cache key if the operations are done using Coherence's "EntryProcessor" feature. And Coherence has a unique feature called "partition-level transactions" which guarantees atomic writes of multiple cache entries (even in different caches) without requiring JTA / XA distributed transaction semantics.

    Read the article

  • Motherboard HDDPWR1 connector

    - by Eric Leschinski
    I need help identifying the name of a connector. I have a Gateway DX4870-UB318 computer, I opened the case and wanted to attach another hard drive, but to my surprise one existing SATA hard drive was connected to the motherboard with this connector: And here is the spot on the Motherboard where the power was supplied. What is the name of this adapter and where can I get another one? Clues: This computer was bought new October 2013 from best buy, box number: DX4870-UB318. The gateway folks won't divulge the type of motherboard it has nor give specs on it. On the wire itself is an identification code: H.35090NJ01-000 Next to the connector on the motherboard it says: HDDPWR1 and the second one says HDDPWR2. This cable has two SATA power connectors and one mystery connector. The power supply has no molex power cables and no SATA power connectors! This is the most bizarre hard drive power system I've seen. I guess the motherboard folks are trying to remove the burden for desktop power supplies to provide adapters (molex, SATA, other) to CD's and hard drives. Can someone put a name on that white flat 6 pin HDD Power Connector? My Solution I can buy a "SATA Power Y Splitter Cable" to provide more spaces to power sata devices.

    Read the article

  • eMachine W5243 won't POST; fans run but optical drive will not open.

    - by NicciAdonai
    Symptoms are what is described in the title. The machine reacts to the power button being hit by spinning up the two fans: CPU and PSU. The hard drive (SATA) spins up as well. No other reaction. This one symptom is particularly weird, though: the optical drive will not open with the IDE cable attached, but if I unplug it from the mobo it will. I can turn the PC on with it attached, won't open; then unplug IDE while it is still on, WILL open; then plug IDE back in with the PC STILL ON, WON'T open. I have disconnected every peripheral unnecessary to POST. These include: mouse/keyboard, PCI modem, the IDE optical drive (power and data), and the SATA HDD (power and data). Video is onboard. The only two things connected are DB15 video and power cable. There were 2 512 MB DDR2 sticks of RAM in it. I have tried running it with just one of them, then switched the other in. Currently seated is a completely different 1 GB stick that I keep around for troubleshooting purposes, and I have tried it in both slots. I have replaced the CMOS battery with a used one I had lying around, and which worked in the computer it came out of. I have tested the PSU with a tester to confirm it was good, then tried connecting another PSU just in case--same symptoms. I have even tried a suggestion I found elsewhere on this site wherein one disconnects power from the PSU and then presses the PC's power button twice, thereby "resetting" the PSU. Currently I am trying yet another suggestion: turn it on and wait an inordinate amount of time for POST. Any help would be appreciated.

    Read the article

  • How do I find out the Mac Address Firefox submits for Geolocation?

    - by Jim McKeeth
    I moved, but have the same router and cable box. Now when I visit Google Maps it still shows my old location. I went to the SkyhookWireless update page to update my Mac Address with my new location. The process is you put in your Mac address and it shows you the current location, and then you adjust that location and submit it. When I got the Mac Address from the status page on my router Skyhook reported that location as in Pakistan, which isn't even the correct continent (as my old or new address). I tried every other Mac address I could come up with: The cable router, the Wireless router's other Mac address, my PC's Mac address, etc. and none of them reported any location on the Skyhook page. So I am guessing that there is another Mac address, or some other bit of information that is used by Firefox when it reports to Google Maps my current location. Now that you have the back story, how do I find the Mac address or whatever information it is that Firefox (or other browsers) use to determine my Geolocation? Everything I have read online is rather vague. The next option I am considering is hooking a logging proxy onto Firefox and seeing what data it sends, but I'd rather find an easier method. Related: How do I update the geo location of my house?

    Read the article

  • Cisco SG 300-28P PoE switch appears to have damaged my domain server's network IF

    - by cdonner
    I just replaced the old HP ProCurve switch with a new Cisco SG 300-28P managed switch. It has PoE on all ports. Everything works, except for my domain server that went offline and the network interface appears to be dead. Windows says the network cable is disconnected, and no lights blink on the switch. Tried different cables and different ports on the switch. The Cisco PoE ports are supposed to be auto-sensing, i.e. not to send power to a device that cannot handle it. Is this technique not 100% reliable? The server is a SHUTTLE XS35V2 with an onboard network chip, so it is probably fried. My questions: is this plausible? who's fault is it - Shuttle or Cisco (i.e. which support line should I try first)? UPDATE: I did go back and tried another switch between the server and the Cisco switch, and indeed, the connection came back to live. When everything is powered down and I start fresh, with the server connected to the Cisco switch, the port light will blink for a while and the connection status is "No Internet connection" at first until it goes off after about 20 seconds and the connection status changes to "Network cable disconnected". On the other switch it works. Clearly not a PoE issue now. I will start looking into the Cisco's onboard diagnostic functions, but so far I have not noticed anything unusual in the log.

    Read the article

  • switchless Infiniband between two servers on RHEL 6.3

    - by exfizik
    I have 2 servers running RHEL 6.3 which have 2 port Infiniband cards >lspci | grep -i infini 07:00.0 InfiniBand: QLogic Corp. IBA7322 QDR InfiniBand HCA (rev 02) I'm interested in connecting them directly to each other bypassing an Infiniband switch (which I don't have). Quick googling showed that at least in some configurations it's possible. I installed all RedHat Infiniband packages with yum groupinstall "Infiniband Support". However, ibv_devinfo shows that both ports in each card are down, which indicates that cables are not connected. But the cable is connected, although the LEDs are off on the cards (not a good sign). Another source of confusion for me is that according to this, RedHat doesn't come with OFED packages and I'm slightly hesitant to install them from source due to the lack of RedHat support for them... So where am I going with this? The questions I have are: is it possible to have a switchless/direct Infiniband connection between two servers the way I described above? If it's possible, do I have to use the OFED packages or can I configure everything with just the packages coming with RHEL. Why are the LEDs off on my servers even though the cable is connected? Any additional input/advice/pointers would be appreciated. P.S. I followed this guide for installation instructions. The Infiniband cards are clearly recognized by my OS and the rdma service is running. Update: I have opensm installed. When I run it it says: OpenSM 3.3.13 Command Line Arguments: Log File: /var/log/opensm.log ------------------------------------------------- OpenSM 3.3.13 Entering DISCOVERING state Using default GUID 0x1175000076e4c8 SM port is down and stays at that point.

    Read the article

  • Broken Creative DTT3500 Digital

    - by djechelon
    Hello, many years ago I bought a Creative DTT3500 Digital surround speakers system. It's been a while since my home theatre started behaving strange. During the past 6 months, I have noticed that the amplifier needed some time before correctly playing digital audio. Until a couple of weeks ago, it needed up to 5 minutes of very noisy "warm up" before playing an "almost" clear audio. Today, I found that even using the analog input (completely disabling digital inputs) the noise persists. Powering off and on the speakers doesn't work. Now, it's reasonable that after almost 10 years, the amplifier got broken. My problem is that I can't simply replace the speakers with another kit from another brand, since 2 speakers in my room are placed in the back wall, with coaxial cables going under the floor but not completely inside a single tube. I mean, I have coaxial extension cables starting from the DTT3500 amplifier, going into the wall, then under the floor in a plastic cable tube, then exiting the tube (still under the floor), connecting to the male coaxial connector of the original cable supplied by Creative, and continuing up to the point close to my bed where the speakers are. I could replace the speakers **only as soon as the new speakers have the same coaxial to bi-polar cables that Creative ships with DTT3500 Another option might be "repairing the amplifier", but I don't know if it's feasible, what should I or a technician look for in the amplifier, and how much would it cost (is it worth to repair or buy a new kit considering the problem above? What do you suggest me to do, basing on the above observation? Thank you.

    Read the article

  • Dual VGA monitors with Quadro FX 580?

    - by dentrasi
    I have a machine with a Quadro FX 580 card (DVI and two Displayport). Attached to it are two 19" Acer screens, which are both (annoyingly) VGA. The first one works perfectly, with a DVI-VGA adaptor. The second one doesn't work. It's got a VGA cable, which goes into a VGA-DVI converted, which then goes into a DVI-Displayport converter. Initally, I was getting 'Cable Unplugged' on the screen, and it couldn't be seen by Windows or the nVidia control panel. After swapping the VGA-DVI adaptor (which works perfectly on another machine), Windows can now see the monitor. The nVidia panel sees the model and native resolution, but I get a constant 'No Signal' error. Switching to the other Displayport makes no difference. I suspect that the card is seeing a DVI connection plugged into it (nVididaCP shows the monitor as having a DVI connection), and it only sending out a digital signal because of this. Does anyone know of a solution (other than trying to get a Displayport-VGA adaptor), or of a way to force the card to see it as VGA? Thanks, ~Dentrasi

    Read the article

  • IDE/PATA high-speed hard drive dock

    - by wfaulk
    I frequently need to access bare drives for backups and need a quick, high-speed way to deal with them. There are a multitude of SATA hard drive docks (for example), but I have a lot of IDE/PATA (hereafter "IDE") drives that I would like to be able to use similarly. There are IDE-to-SATA adapters so you can plug your IDE hard drive into a SATA port, so I don't see any reason why you couldn't use the same technology to have a native dock, yet none seems to exist. Now, I'm aware that 3.5" IDE drives do not have a specification for the layout of the connector, and therefore can't be slapped into a dock the same way a SATA drive could, but 2.5" PATA drives do. In fact, I'm not terribly interested in supporting 3.5" drives. It would be nice, but I deal with them far less frequently than 2.5" drives. Also, I'd very much like for the connection to the computer be faster than USB, preferably eSATA, I don't want to be spending time mounting a drive inside an enclosure, I don't want bare drives lying around with a cable hanging off of them, and I'd prefer a single dock rather than two. What seems like the ideal solution to me would be a regular SATA→eSATA dock and some sort of screwless adapter for IDE drives, but I'm open to any suggestions, regardless of my stated preferences, but which are, in some sort of order of preference: high-speed (faster than USB, at least) holder for drive (not just a cable) no complicated enclosure support for 3.5" IDE drives single dock Updates: Here's a 3.5" IDE to 3.5" SATA docking adapter that could be part of the solution. Weird. I figured that would be the impossible part. I was hoping to find something like this 2.5" to 3.5" SATA chassis that would take a 44-pin IDE drive internally. It looks like the Vantec EZ Swap EX comes awfully close. It has its own bay dock, but it looks like the SATA ports on the back are spaced properly, even if they're not aligned quite properly. Unfortunately, the proper position is at the very edge of the drive, which means that the docks' connectors are at the very edge of their recesses, which means there's no way to fit it in there.

    Read the article

  • Can't connect two PCs to a Network Switch at the same time (Windows 7)

    - by puk
    I have two computers connected to a network switch and every once in a while one of the computers will lose its internet connection. It's almost always the same computer every time. However, if I play around with the control panel, I can switch it, so that now the other computer is not connected. Restarting either of the computers does not help either. In Windows, the worlds-greatest-trouble-shooter tells me that a network cable is unplugged and that I should try plugging it in...Disabling and re-enabling my NIC does not fix this problem, neither does swapping cables around. When rebooting, the BIOS complains about how the Ethernet Cable is not plugged in. If it's in any way important, My set up at the office is like so: Modem - Routher - Network Switch 1 - Network Switch 2. I have tried turning off the energy saving option for my NIC, and I tried manually setting the link-speed to 100Mbps Full Duplex without any luck. Also, I have a Realtek PCIe GBE Family controller on both computers Does anyone have any idea why this is happening every 5-10 days? EDIT: I have also tried using a completely different Network Switch and the problem still persists as before.

    Read the article

  • Joining two routers together, but I have no access to the second router, although I know it's IP address and Gateway

    - by JohnnyVegas
    I have temporarily moved into a rented apartment for 4 months, which has wireless. The trouble I am having is that the access points here are wifi only and no RJ45 and I need to use RJ45 to connect some equipment that I am working with. I have purchased an RT-N66U and installed Tomato (shibby ver. 1.28) and successfully replaced the existing access point, but now I want to enable the access point that I have replaced as it links wirelessly to 3 others. Can I plug in a cable from the access point to my RT-N66U and get it to access the internet via my router? I have no access to the existing wireless access point, and don't want to reset it as it's not mine. There is another router situated in the roof somewhere which I also have no access to, but it's supplying my RT-N66U internet and I most definitely have a double-nat, which although isn't the best way of doing things I am limited with what I can do. Any suggestions on routing tables, vlans etc would be helpful, but I have no experience in these fields before - but I know the tomato firmware can cater for this. My router is set to IP 10.0.1.1 and dhcp is 10.0.1.100-200 The wireless access point address was 192.168.1.2 but this was assigned by the router in the roof which has the address 192.168.1.1. There is a cable from this router going to a wall socket which I now have my RT-N66u attached to via the WAN port. I understand it's scruffy and it isn't the way to do things but I have tried to ask for the admin details but as the wireless network is looked after by a third party and nobody knows their details I am stuck with this dilemma. I could buy three wireless access points and replace the existing but this isn't what I want to do, and although I have installed plenty of DD-WRT wireless repeater bridges they simply don't work here for some unknown reason. The phone line here is very noisy too and I don't have the rights to install ADSL in a building that isn't mine, and 3G coverage isn't good enough either. Thanks for your time

    Read the article

  • Monitor connected with WiDi just shows a black screen

    - by Pops
    I have a Dell XPS 18 and want to use an external monitor with it. The monitor has VGA and DVI-D inputs. The XPS 18 has no video output ports, but it does support Intel WiDi. I have a Netgear P2TV2000 WiDi receiver, but it only has composite and HDMI outputs. I'm connecting the receiver to the monitor with an HDMI cable and an HDMI/DVI-D adapter. So, in short, the video path is: Computer → WiDi → WiDi receiver → HDMI cable → HDMI/DVI-D adapter → Monitor After setting all this up, I can't get anything to display on the monitor. At the moment I power the monitor on, I can see my desktop for a brief fraction of a second, and then everything goes black. All of the relevant drivers have been updated to the latest versions. When I use a different WiDi-enabled computer to connect to the same monitor, everything works fine. When I use the original computer and receiver to connect to a TV, everything works fine. It's only when I connect the original computer to the monitor I want to use that the connection fails. What could be going wrong here, and how can I get the video to work consistently?

    Read the article

  • Linksys WAP54G v3.1 no access, power and link LED solid

    - by user142113
    I'm managing the Network of a small enterprise. A Linksys WAP54G v3.1 used to provide the WiFi network. I was called, because the device did not provide a WiFi network anymore. I first of all tried to ping the device via LAN, but there was no reaction. I've frequently reconnected the AP to the mains and always the POWER and the LINK LED keep solid, even if no network cable is connected. What I've done yet: Reset as documented: Pressed the RESET button for 10 seconds. After that I have tried to access the AP with a direct cable connection to my computer, that I've set to a static ip of 192.168.1.240, but i got no ping response on the default IP 192.168.1.245. Furthermore ipconfig reports "media disconnected". More complex reset method as described here http://bruceshankle.blogspot.de/2005/12/how-to-reset-linksys-wap54g.html as well had no effect. also tried to ping 192.168.1.1 without success Tried this method: http://www.daniweb.com/hardware-and-software/networking/threads/142437/linksys-wireless-access-point-problem#post680245 but there was no ping response when powering up. As well the tftp transfer timed out Finally tried to short pin 15 and 16 of the flash chip on the bottom side of the AP mainboard while booting to provoke a Checksum error. This should lead to the possibility to upload a firmware with tftp, as the AP stops booting and waits for a tftp connection on 192.168.1.1. But I've had no success. As well i've put pin 15 and 16 to ground while booting, also without an effect. After all that I still can't ping the AP, ipconfig still tells me "media disconnected". The POWER and LINK LED are solid. I would appreciate your answers

    Read the article

  • connect server to server on secondary NIC

    - by microchasm
    Hi, I have a CentOS box with multiple NIC's running Apache. I also have another box running RHEL that will be the MySQL server. I'm trying to use the secondary NIC on the Apache box to connect directly to the MySQL server, but so far no luck. I want to isolate the MySQL box as much as possible which is why I'm going for a direct connection as opposed to running through a switch. I have a crossover cable running between them. IP configs: Apache box eth0 [to lan] ip addr: 192.168.200.100 netmask: 255.255.0.0 gateway: 192.168.111.1 eth1 [to mysql] ip addr: 192.168.200.101 netmask: 255.255.0.0 gateway: [blank] MySQL box eth0 [to apache] ip addr: 192.168.200.203 netmask: 255.255.0.0 gateway: 192.168.200.201 The rest of our network is on 192.168.111.0/24 subnet. Ping only returns Destination Host Unreachable. I've tried various variations of this setup (including straight through cable), and I can't seem to get them to talk to each other. Any help appreciated.

    Read the article

  • LCD monitor flicker when connected to a laptop using VGA

    - by Björn Lindqvist
    I have a dual screen setup with two AOC e2450Sw monitors connected to a laptop. The laptop has one HDMI and one VGA output. When one of the monitors is connected using VGA, it flickers or displays static noise. The flickering is fairly subtle and only visible on darker colors. But it is there and noticable and appears like horizontal lines. The problem only appears on the monitor connected to the laptop using the VGA cable. If I swap the monitors, the one connected using VGA is displaying the flicker but not the one connected using HDMI. The simple solution would ofcourse be to connect both monitors using HDMI, but since the laptop only has one VGA and one HDMI out that isn't possible. I've tried tweaking the monitor setting using the OSD menu, but it had little or no effect. Update: After several more trouble shooting hours, it seems the problem is not related to the monitor or VGA cable as the problem persists even if I swap the display with another brand and different cables. So it may be the graphics card? Intel HD Graphics 4000. The laptop is Acer Aspire E1-571.

    Read the article

  • Dell Poweredge 1950 with Perc 5i keeps losing raid config -> "Foreign Configuration Found"

    - by nosage
    The quick and dirty: the machine is a Dell Poweredge 1950, dual xeon quad cores, 8GB of ram, 2 2TB seagate SATAs in (supposed to be raid1) using a Perc 5i raid card. They are hot-swappable with a back-plane. I can build the raid fine and after a little while an install of server 08 r2 will blue screen and restart. When it comes up the raid controller says "Foreign Configuration Found." When I go into the raid configuration panel there is no raid listed but I can import the "foreign config", and the OS will boot up fine, until it blue screens again after a little while. The issue is OS independent. I have tried swapping raid cards, swapping the RAM module on the raid card and swapping the raid battery, all to no avail. Its almost as if there is a loose connection from the raid card to the back plane and both of disks get lost and the raid card drops the config. But it sees the disks fine when it boots back up. The raid card uses a SCSI SAS cable to connect to the back-plane so I guess the next step is to replace that, but... then I might as well replace the back-plane with a SCSI SAS to sata breakout cable, but... then I need a way to power the disks. Sorry for the wall of txt but it would be great to get some thoughts from people who worked with perc raid cards or poweredge servers with this type of issue before. Ironically I want to get this system up and running so I can work on MCITP labs. Thank you for any/all help and feel free to ask questions!

    Read the article

  • What keeps you from changing your public IP address and wreak havok?

    - by Whitemage
    An interesting question was asked to me and I did not know what to answer.. So I'll ask here. Let's say I subscribed to an ISP and I'm using cable internet access. ISP gives me a public IP address of 60.61.62.63. What keeps me from changing this IP address to, let's say, 60.61.62.75 and mess with another consumer's internet access? For the sake of this argument, let's say that this other IP address is also owned by the same ISP. Also, let's assume that it's possible for me to go into the cable modem settings and manually change the IP address. Under a business contract where you are allocated static addresses, you are also assigned a default gaetway, a network address and a broadcast address. So that's 3 addresses the ISP "loses" to you. That seems very wastefull for dynamically assigned IP addresses where the majority of customers are.. Could they simply be using static arps? ACLs? Other simple mechanisms? Anyone who worked at an ISP would be willing to explain this a bit?

    Read the article

  • Why can't I route to some sites from my MacBook Pro that I can see from my iPad?

    - by Robert Atkins
    I am on M1 Cable (residential) broadband in Singapore. I have an intermittent problem routing to some sites from my MacBook Pro—often Google-related sites (arduino.googlecode.com and ajax.googleapis.com right now, but sometimes even gmail.com.) This prevents StackExchange chat from working, for instance. Funny thing is, my iPad can route to those sites and they're on the same wireless network! I can ping the sites, but not traceroute to them which I find odd. That I can get through via the iPad implies the problem is with the MBP. In any case, calling M1 support is... not helpful. I get the same behaviour when I bypass the Airport Express entirely and plug the MBP directly into the cable modem. Can anybody explain a) how this is even possible and b) how to fix it? mella:~ ratkins$ ping ajax.googleapis.com PING googleapis.l.google.com (209.85.132.95): 56 data bytes 64 bytes from 209.85.132.95: icmp_seq=0 ttl=50 time=11.488 ms 64 bytes from 209.85.132.95: icmp_seq=1 ttl=53 time=13.012 ms 64 bytes from 209.85.132.95: icmp_seq=2 ttl=53 time=13.048 ms ^C --- googleapis.l.google.com ping statistics --- 3 packets transmitted, 3 packets received, 0.0% packet loss round-trip min/avg/max/stddev = 11.488/12.516/13.048/0.727 ms mella:~ ratkins$ traceroute ajax.googleapis.com traceroute to googleapis.l.google.com (209.85.132.95), 64 hops max, 52 byte packets traceroute: sendto: No route to host 1 traceroute: wrote googleapis.l.google.com 52 chars, ret=-1 *traceroute: sendto: No route to host traceroute: wrote googleapis.l.google.com 52 chars, ret=-1 ^C mella:~ ratkins$ The traceroute from the iPad goes (and I'm copying this by hand): 10.0.1.1 119.56.34.1 172.20.8.222 172.31.253.11 202.65.245.1 202.65.245.142 209.85.243.156 72.14.233.145 209.85.132.82 From the MBP, I can't traceroute to any of the IPs from 172.20.8.222 onwards. [For extra flavour, not being able to access the above appears to stop me logging in to Server Fault via OpenID and formatting the above traceroutes correctly. Anyone with sufficient rep here to do so, I'd be much obliged.]

    Read the article

  • Copying large files from USB devices to the internal hard drive fails on Mac OS

    - by John M. P. Knox
    I have a second-generation 13" MacBook Air running Mac OS X 10.6.6 with a 2.13 GHz processor, 4 GB of RAM, and a 256 GB SSD hard disk. I often get failures when I attempt to copy a large file or large collection of files from an external USB drive (typically a "Firewire" generation Drobo) to the internal drive. The failure behaves almost exactly as if I had pulled the USB cable from the computer in mid-transfer. I get a warning that I have removed the hard disk improperly. After this event, the drive no longer appears mounted in the finder, and I have to unplug and reinsert the USB cable to mount the drive again. I have also seen a similar problem when using Aperture 3 to import a large number of photos and videos from a USB Compact Flash card reader. The import will fail and I will have to unplug the Card Reader and import the missing items. Oddly, reversing the direction of the copy seems pretty reliable. I've never had a problem copying a large file to a USB device, meaning that I have quite a few large files which are stranded on my Drobo. Model Identifier: MacBookAir3,2 Boot ROM Version: MBA31.0061.B01 I have seen a similar issue reported on Apple's website: http://discussions.apple.com/thread.jspa?threadID=2648590&tstart=0 The only suggested resolutions there seems to be switching to another form of connectivity (e.g. firewire, which does not exist on MacBook Air), or downgrading to Mac OS 10.6.4, or reverting the USB kernel extensions to the 10.6.4 versions: http://discussions.apple.com/message.jspa?messageID=12566073#12582956 I'm not too keen on the idea of downgrading kernel extensions. Does anyone know of a hardware revision without this issue that I can trade up to? Are there any other potential solutions out there?

    Read the article

  • Moving Farm to co-location hosting - network settings requirements

    - by Saariko
    I am moving my farm (2 Dell's R620) to a co-location hosting service. I am trying to figure out the secure way to have my network settings The requirements are: VM1 is the working HOST, includes: esxi 5.1, vSphere, 4 clients (w2008r2 all) VM2 has esxi 5.1 installed, and a single machine with Veeam Backup and copy 6.5 - keeping a copy of VM1 clients on the VM2 internal storage (this solution is due to a very small budget - in case of failure on Host 1 - can redirect IP's) Only 2 VM clients require network address and access from the WWAN - ISP provides IP's range for them (with Gateway and DNS) I need connection to the iDrac's from my office (option to create a VPN-SSL tunnel) Connection to the vSphere appliances I want to be able to RDP to the VM clients The current configuration is that each host has the iDrac dedicated nic connected , and another (NIC #1) connected - with a static IP on 192.168.3.x The iDrac's have a static IP from the same network range (19.168.3.x) It will look something like this: My thoughts: On NIC#2 of both hosts I will connected a crossed cable I will give each VM clients that needs internet access a 2ndry VM network with the assigned IP from the ISP open only to web - can not access from the My Question: Should I give IP's (external) to the machines who DO NOT require WWAN Access? - I can't see a way to RDP to them directly if not. Should I use the crossed cable? or just plug NIC #2 to the switch? Will this setup even work? What do I need to verify? What Virtual nic's and/or switches should I create on the Hosts?

    Read the article

  • Intel D2500HN Atom D2500 Doesn't turn on

    - by David W
    I recently bought parts from Amazon to build an embedded PC, and have assembled everything. I have: Intel D2500HN Mini-ITX Motherboard Mini-Box Pico-PSU 80 M350 Universal Min-ITX Enclosure 2GB DDR3 Memory Kinamax AD-LCD12 LCD Monitors 12V 6A 72W AC Adapter Power Supply The motherboard gets a light (on the motherboard, not on the Pico-PSU) when I plug it into the power adapter. Furthermore, I see the power switch light come on when I press the power button. However, the display doesn't turn on, and it doesn't seem that the PC is actually turned on. Since I'm seeing these lights, I know that the motherboard is getting power. Furthermore, the display VGA port is embedded into the motherboard, so that's not the issue. I'm just trying to figure out what COULD be the issue aside from a faulty motherboard. I have a diagram of the D2500HN motherboard which labels everything, and have ensured that the power LED as well as the On/Off cables are plugged into the right spots, although to be sure I've tried flipping these two cables around, and also plugging 1 cable into the other cable's spot & vice-versa. Is there anything else you folks think I may be missing, or anything else I can do to try to troubleshoot this issue before sending the motherboard back?

    Read the article

  • How to set up a serial connection to a Windows 7 computer

    - by oli_arborum
    I need to set up a "dial in" connection to a Windows 7 (Ultimate) computer via a serial null-modem cable to be able to connect from a Windows XP client to that computer and exchange data over IP. Question 1: How do I do that? I did neither find the information via Google nor in the MSDN. Seems like no one tried ever before... ;-) I already managed to install a legacy modem device called "Communications cable between two computers" and found the menu entry "New Incoming Connection..." in Network and Internet Network Connections. When I finish this wizard I get the message that the "Routing and Remote Access service" cannot be started. In the event viewer I see the following error messages: "The currently configured authentication provider failed to load and initialize successfully. The requested name is valid, but no data of the requested type was found." (Source: RemoteAccess, EventID: 20152) "The Routing and Remote Access service terminated with service-specific error The requested name is valid, but no data of the requested type was found." (Source: Service Control Manager, EventID: 7024) The Windows 7 installation is "naked", i.e. no additional software or services are installed. Question 2: Am I on the right path to set up the connection? Question 3: How can I get the Routing and Remote Access service running?

    Read the article

< Previous Page | 236 237 238 239 240 241 242 243 244 245 246 247  | Next Page >