Search Results

Search found 16940 results on 678 pages for 'disk drive'.

Page 243/678 | < Previous Page | 239 240 241 242 243 244 245 246 247 248 249 250  | Next Page >

  • xen-create-image does not create inird or initramfs image and domU does not starts with system image

    - by user219372
    I have Fedora 19 as Dom0. To create image I run # xen-create-image --hostname=debian-wheezy --memory=512Mb --dhcp --size=20Gb --swap=512Mb --dir=/xen --arch=amd64 --dist=wheezy After generation finished I start vm and see: # xl create /etc/xen/debian-wheezy.cfg Parsing config from /etc/xen/debian-wheezy.cfg libxl: error: libxl_dom.c:409:libxl__build_pv: xc_dom_ramdisk_file failed: No such file or directory libxl: error: libxl_create.c:919:domcreate_rebuild_done: cannot (re-)build domain: -3 In the /etc/xen/debian-wheezy.cfg i have # # Kernel + memory size # kernel = '/boot/vmlinuz-3.11.2-201.fc19.x86_64' ramdisk = '/boot/initrd.img-3.11.2-201.fc19.x86_64' and ls -1 /boot/*201* shows /boot/config-3.11.2-201.fc19.x86_64 /boot/initramfs-3.11.2-201.fc19.x86_64.img /boot/System.map-3.11.2-201.fc19.x86_64 /boot/vmlinuz-3.11.2-201.fc19.x86_64 Then if I fix ramdisk directive in .cfg file to /boot/initramfs-3.11.2-201.fc19.x86_64.img vm will start but os inside will not boot. In a tail of xl console I get [ OK ] Reached target Basic System. dracut-initqueue[130]: Warning: Could not boot. dracut-initqueue[130]: Warning: /dev/disk/by-uuid/085883ad-73ca-45cc-8bc5-e6249f869b26 does not exist dracut-initqueue[130]: Warning: /dev/fedora/root does not exist dracut-initqueue[130]: Warning: /dev/fedora/swap does not exist dracut-initqueue[130]: Warning: /dev/mapper/fedora-root does not exist dracut-initqueue[130]: Warning: /dev/mapper/fedora-swap does not exist dracut-initqueue[130]: Warning: /dev/xvda2 does not exist Starting Dracut Emergency Shell... Warning: /dev/disk/by-uuid/085883ad-73ca-45cc-8bc5-e6249f869b26 does not exist Warning: /dev/fedora/root does not exist Warning: /dev/fedora/swap does not exist Warning: /dev/mapper/fedora-root does not exist Warning: /dev/mapper/fedora-swap does not exist Warning: /dev/xvda2 does not exist Generating "/run/initramfs/sosreport.txt" Entering emergency mode. Exit the shell to continue. Type "journalctl" to view system logs. You might want to save "/run/initramfs/sosreport.txt" to a USB stick or /boot after mounting them and attach it to a bug report. dracut:/# .img files in /xen/domains/debian-wheezy exists and listed in disk section of debian-wheezy.cfg So what should i do? Update: I've found that xl does not mount images. In debian-wheezy.cfg I have that: root = '/dev/xvda2 ro' disk = [ 'file:/xen/domains/debian-wheezy/disk.img,xvda2,w', 'file:/xen/domains/debian-wheeze/swap.img,xvda1,w', ] And there is no /dev/xvda* or /dev/sda* or /dev/hda* files in VM.

    Read the article

  • Easy Install Resets Hardware Settings

    - by bob5972
    I think there's a problem with the Easy Install setup. I selected "Installer disc image," and it came up and said that it would use "Easy Install," I think I hit next, and then I went back changed my mind, and selected "I will install the operating system later." After finishing the wizard, I think it still went and ran Easy Install, because it auto-installed VMware tools and I never got to select anything for my windows setup. Then, when it was finished, all the hardware changes I had made were lost. The RAM was changed from 2 GB back to the default of 1 GB, my CD ROM drive was set back to "Use a Physical Drive" and "Connect at Power On", and the Floppy Drive was also set to "Connect at Power On", after I disabled them. I was trying to install Windows 7, and I wasn't sure if I could change the RAM settings after installation without needing to reactivate it, so I deleted the VM and tried to start over. This time, the "Installer disc image" had my Win7 image pre-selected, so I clicked "I will install it myself later," set my hardware again, and tried to boot off my CD. Again,it did an Easy Install, and reset my RAM and my drive settings. So I deleted it again and the third time it still had the Win7 image pre-selected, but this time I unplugged all the drives and let it try to boot off the empty harddrive and fail, and made sure it kept all my hardware settings. Then, I powered it off, put my Win7 image in the guest CD ROM, and powered it on. This time it finally let me run the installer and pick my language, and type a user name. This time when I powered it off it kept my hardware settings. I can duplicate the error by doing exactly the steps above. Creating a new VM, selecting my "Installer Image," hitting next, going back, selecting "I will Install it myself," and then finish the wizard, and customizing my hardware right before the end, setting the CD Rom drive to the same installer media, and setting "Connect on Power On." (If I start it without the CD ROM in the first time, it doesn't do it). When I power on, I'm not prompted for any install information (like language and user name), and when it runs the first timemy hardware choices are reset (like the RAM back to 1 GB). If it helps, I'm running VMware Workstation 7.0.1 build-227600 on Gentoo Linux

    Read the article

  • Easy Install Resets Hardware Settings

    - by bob5972
    I think there's a problem with the Easy Install setup. I selected "Installer disc image," and it came up and said that it would use "Easy Install," I think I hit next, and then I went back changed my mind, and selected "I will install the operating system later." After finishing the wizard, I think it still went and ran Easy Install, because it auto-installed VMware tools and I never got to select anything for my windows setup. Then, when it was finished, all the hardware changes I had made were lost. The RAM was changed from 2 GB back to the default of 1 GB, my CD ROM drive was set back to "Use a Physical Drive" and "Connect at Power On", and the Floppy Drive was also set to "Connect at Power On", after I disabled them. I was trying to install Windows 7, and I wasn't sure if I could change the RAM settings after installation without needing to reactivate it, so I deleted the VM and tried to start over. This time, the "Installer disc image" had my Win7 image pre-selected, so I clicked "I will install it myself later," set my hardware again, and tried to boot off my CD. Again,it did an Easy Install, and reset my RAM and my drive settings. So I deleted it again and the third time it still had the Win7 image pre-selected, but this time I unplugged all the drives and let it try to boot off the empty harddrive and fail, and made sure it kept all my hardware settings. Then, I powered it off, put my Win7 image in the guest CD ROM, and powered it on. This time it finally let me run the installer and pick my language, and type a user name. This time when I powered it off it kept my hardware settings. I can duplicate the error by doing exactly the steps above. Creating a new VM, selecting my "Installer Image," hitting next, going back, selecting "I will Install it myself," and then finish the wizard, and customizing my hardware right before the end, setting the CD Rom drive to the same installer media, and setting "Connect on Power On." (If I start it without the CD ROM in the first time, it doesn't do it). When I power on, I'm not prompted for any install information (like language and user name), and when it runs the first timemy hardware choices are reset (like the RAM back to 1 GB). If it helps, I'm running VMware Workstation 7.0.1 build-227600 on Gentoo Linux

    Read the article

  • Trouble with Wubi and dual boot install

    - by noam
    Is there a difference between wubi install and doing an install of Ubuntu alongside windows7? I ask because I used wubi, but I'm having trouble with certain things like being unable to change my brightness settings and I'm wondering if installing from a usb drive would change anything. Also, I've tried to do a usb drive install, but it doesn't give me the option to install alongside, it only shows the "Replace Windows 7" and "something else" options. Is this because I already did a wubi install?

    Read the article

  • Oracle Customer Experience Summit @ OpenWorld

    - by Christie Flanagan
    This first-ever Oracle Customer Experience Summit @ OpenWorld kicked off yesterday, bringing together established thought leaders and practitioners in customer experience. The first day saw noted marketing and customer experience thought leader, Seth Godin, take the stage to discuss how rapidly accelerating change and adoption are driving new behaviors and higher expectations in a massively disruptive transformation in which the customer now holds the power. His presentation gave us in-depth insight into this always-connected, always-sharing experience revolution we are witnessing.If you haven’t yet made it over to the Oracle Customer Experience Summit at The Westin St. Francis and the recently made over Oracle Square (aka Union Square), there’s still time today and tomorrow to network with industry peers and hear best practices from those who have steered their ventures through the disruptive trends of customer experience and have proven, successful strategies to share for driving strategic customer-centric initiatives. If you’re interested in learning how Oracle WebCenter helps businesses meet the demands of the customer experience revolution, be sure to check out these sessions at the Oracle Customer Experience Summit later today:Using the Online Customer Experience to Drive Engagement and Marketing Success Thursday, Oct 4, 4:15 PM - 5:15 PM - St. Francis - GeorgianMariam Tariq - Senior Director Product Management, Oracle Stephen Schleifer - Senior Principal Product Manager, Oracle Richard Backx - Business IT Architect/Consultant, KPN NL Netco CE Channels Online The online channel is a critical means of reaching and engaging customers. Online marketing efforts today must be targeted, interactive, and consistent to provide customers with a seamless experience. These efforts must include integrated management of Web, mobile, and social channels—supported by cross-channel customer data and campaigns—and integration with commerce to drive an engaging and differentiated online customer experience. Attend this session to learn how you can use the online channel to increase customer loyalty and drive the success of your marketing initiatives.Empowering Your Frontline Employees: Sales and Service Enterprise Collaboration Thursday, Oct 4, 5:30 PM - 6:30 PM - St. Francis - Elizabethan ABStephen Fioretti - VP, Product Management, Oracle Peter Doolan - Group Vice President, Sales Engineering, Oracle Andrew Kershaw - Sr Director Business Development, Oracle Marty Marcinczyk - VP Customer Experience Engineering, Comcast A focus on the employee experience is critical, because it can make or break your customers’ experiences, directly or indirectly. Engaged and empowered frontline employees become your best advocates and inspire your brand champions. This session explores proven approaches and tools, including social collaboration tools, that can help you empower and enable your frontline teams to improve customer and employee experiences.And before you go, you'll also want to explore the Innovation Tents in Oracle Square which feature leading-edge customer experience demonstrations; attend our customer journey mapping workshop; and learn at sessions focused on innovating differentiated experiences that drive cross-functional alignment.

    Read the article

  • unable to save files from Code Blocks ONLY

    - by ths
    i have an NTFS drive mounted in a folder /Tejas i have created a new project using it in a folder in this drive but i am unable to save the changes, i get the following error message Couldn't save project /Tejas/Project/codeblock/ciphers/ciphers.cbp (Maybe the file is write-protected?) i get similar message even when i try to save the c source file i am able to edit and save files using gedit editor... why am i getting this problem?

    Read the article

  • 12.04.1 Error After Upgrade

    - by rambo15
    Just update my dell Inspiron to 12.04.1. Upon reboot I get the following error: The disk drive for / is not ready yet or not present. I press "S" to skip mount and then I get the folllowing error: the disk drive for /tmp is not ready yet or not present. I have already tried the following from the maintanance shell prompt: dpkg --configure -a No luck same error. Any help would be greatly appreciated.

    Read the article

  • Order of partitions for root, home and swap with respect to Windows partitions

    - by Tim
    I am installing Ubuntu on the same hard drive as Windows 7. The partitions of Windows 7 have already occupied the left part of the hard drive. I was wondering how to arrange the order of partitions of root, home and swap, i.e. which is on the left just besides one Windows partition, which is in the middle and which is on the far right? Is there some consideration regarding about this arrangement? Thanks and regards!

    Read the article

  • ubiquity "hangs" on first step

    - by bumbling fool
    Trying to install 11.04 daily for the last couple days but, no matter what I try (wifi connected, wifi not connected, disk blank, disk prepartitioned...), if just "hangs" at the first window (pick your language) with a non-stop hourglass after hitting next. I ran into a different issue when trying to use the alternate installer image. This is on a Stinkpad T42. Should ubiquity at least tell me whats going on?!? I tried to find a log but /var/log/installer* isn't present.

    Read the article

  • Managing Data Growth in SQL Server

    'Help, my database ate my disk drives!'. Many DBAs spend most of their time dealing with variations of the problem of database processes consuming too much disk space. This happens because of errors such as incorrect configurations for recovery models, data growth for large objects and queries that overtax TempDB resources. Rodney describes, with some feeling, the errors that can lead to this sort of crisis for the working DBA, and their solution.

    Read the article

  • unable to mount hard drives

    - by mixtyplix
    I am currently trying to backup data from my computer's hard drive to an external one while live-booting to Ubuntu from a USB, and I've encountered a bit of a problem. You see, I cannot mount my hard drives. Whenever I try, I always get one of two errors: fuse: failed to access mountpoint [file I'm trying to mount to]: No such file or directory or Error mounting: mount exited with exit code 21: mount: according to mtab, [drive] is already mounted on [file I'm trying to mount to] How can I fix this?

    Read the article

  • Adaptec 5805 not recognized after reboot

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not recognized. It only works if the computer is shut down and turned off. I have recently updated the firmware to "Adaptec RAID 5805 Firmware Build 18948". How do I fix the problem? Configuration summary --------------------------- 1. Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priority High Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1

    Read the article

  • Should I install ubuntu on USB instead of HDD dual-boot?

    - by user2147243
    I had Ubuntu 12.04 installed as dual-boot OS on top of Vista on my laptop. Hacked the grub settings to default to Vista (instead of the default Ubuntu -- pain) on startup, and all was OK for occasional Ubuntu use for past 6 months. Then last week I got a strange message about 'lack of disk space' (~50MB free) when installing pxyplot, even though there was still about 6GB free disk space when I checked later. Then today the Ubuntu wouldn't load at all, and checking the HDD partitions in Vista it looked like the 15GB Ubuntu partition was now three smaller partitions! So, I got rid of those partitions and expanded the Vista partition to use the reclaimed space. Now can't restart ('grub rescue' appears and doesn't 'rescue' anything), so I'll have to do a boot recovery using a Vista installation CD. (Not a particularly user-friendly failure mode of the dual-boot installation!) I now have to decide to either a) try installing ubuntu on the HDD again, but don't want to stuff up my Vista ever again, as that is my most used OS, or b) install Ubuntu on a 16GB USB 3.0 stick. Apparently performance from USB won't be as good as from HDD, and running OS from USB stick does lots of r/w so the stick may fail after a few years! Perhaps installing Ubuntu on live USB and setup to then run in RAM would alleviate the performance/USB lifespan problems? If I create a live-USB for Ubuntu OS, will it boot off that when I restart the laptop with it plugged in? Or will I have to change the laptop setting for boot-order whenever I want to boot Ubuntu instead of Vista (that would be even more painful than the grub default boot order putting Ubuntu ahead of the existing Vista OS!) -- update: I recovered my Vista setup using Iolo SystemMechanic Disaster Recovery Tool, and created a bootable USB of Ubuntu 13.10 on an 8GB USB3.0 pendrive, with 4GB of 'persistence' to allow saving of settings, install some packages etc. It worked OK for a couple of test boots, but once I changed the time and desktop wallpaper, the next Ubuntu reboot crashed and I then couldn't get it to boot successfully. So I decided to install Ubuntu 12.04 LTS as a dual-boot again, but this time instead of partitioning the HDD and installing from an ISO DVD I used the wubi.exe tool to install Ubuntu as a dual-boot. Worked very well, although one oddity was that, despite asking how big the make the partition (20GB), the installed Ubuntu appears to be happily installed somewhere within the Vista NTFS file system (no partition shows up in Windows disk manager, and in Ubuntu disk management tool the entire 133 GB of HDD is showing, with ~40GB free space). A nice feature of installing the dual-boot using wubi is that the laptop now uses Windows boot manager on startup, with Vista as the default OS and Ubuntu happily listed as second on the list. So far so good.

    Read the article

  • Oracle Certification and virtualization Solutions.

    - by scoter
    As stated in official MOS ( My Oracle Support ) document 249212.1 support for Oracle products on non-Oracle VM platforms follow exactly the same stance as support for VMware and, so, the only x86 virtualization software solution certified for any Oracle product is "Oracle VM". Based on the fact that: Oracle VM is totally free ( you have the option to buy Oracle-Support ) Certified is pretty different from supported ( OracleVM is certified, others could be supported ) With Oracle VM you may not require to reproduce your issue(s) on physical server Oracle VM is the only x86 software solution that allows hard-partitioning *** *** see details to these Oracle public links: http://www.oracle.com/technetwork/server-storage/vm/ovm-hardpart-168217.pdf http://www.oracle.com/us/corporate/pricing/partitioning-070609.pdf people started asking to migrate from third party virtualization software (ex. RH KVM, VMWare) to Oracle VM. Migrating RH KVM guest to Oracle VM. OracleVM has a built-in P2V utility ( Official Documentation ) but in some cases we can't use it, due to : network inaccessibility between hypervisors ( KVM and OVM ) network slowness between hypervisors (KVM and OVM) size of the guest virtual-disks Here you'll find a step-by-step guide to "manually" migrate a guest machine from KVM to OVM. 1. Verify source guest characteristics. Using KVM web console you can verify characteristics of the guest you need to migrate, such as: CPU Cores details Defined Memory ( RAM ) Name of your guest Guest operating system Disks details ( number and size ) Network details ( number of NICs and network configuration ) 2. Export your guest in OVF / OVA format.  The export from Redhat KVM ( kernel virtual machine ) will create a structured export of your guest: [root@ovmserver1 mnt]# lltotal 12drwxrwx--- 5 36 36 4096 Oct 19 2012 b8296fca-13c4-4841-a50f-773b5139fcee b8296fca-13c4-4841-a50f-773b5139fcee is the ID of the guest exported from RH-KVM [root@ovmserver1 mnt]# cd b8296fca-13c4-4841-a50f-773b5139fcee/[root@ovmserver1 b8296fca-13c4-4841-a50f-773b5139fcee]# ls -ltrtotal 12drwxr-x--- 4 36 36 4096 Oct 19  2012 masterdrwxrwx--- 2 36 36 4096 Oct 29  2012 dom_mddrwxrwx--- 4 36 36 4096 Oct 31  2012 images images contains your virtual-disks exported [root@ovmserver1 b8296fca-13c4-4841-a50f-773b5139fcee]# cd images/[root@ovmserver1 images]# ls -ltratotal 16drwxrwx--- 5 36 36 4096 Oct 19  2012 ..drwxrwx--- 2 36 36 4096 Oct 31  2012 d4ef928d-6dc6-4743-b20d-568b424728a5drwxrwx--- 2 36 36 4096 Oct 31  2012 4b241ea0-43aa-4f3b-ab7d-2fc633b491a1drwxrwx--- 4 36 36 4096 Oct 31  2012 .[root@ovmserver1 images]# cd d4ef928d-6dc6-4743-b20d-568b424728a5/[root@ovmserver1 d4ef928d-6dc6-4743-b20d-568b424728a5]# ls -ltotal 5169092-rwxr----- 1 36 36 187904819200 Oct 31  2012 4c03b1cf-67cc-4af0-ad1e-529fd665dac1-rw-rw---- 1 36 36          341 Oct 31  2012 4c03b1cf-67cc-4af0-ad1e-529fd665dac1.meta[root@ovmserver1 d4ef928d-6dc6-4743-b20d-568b424728a5]# file 4c03b1cf-67cc-4af0-ad1e-529fd665dac14c03b1cf-67cc-4af0-ad1e-529fd665dac1: LVM2 (Linux Logical Volume Manager) , UUID: sZL1Ttpy0vNqykaPahEo3hK3lGhwspv 4c03b1cf-67cc-4af0-ad1e-529fd665dac1 is the first exported disk ( physical volume ) [root@ovmserver1 d4ef928d-6dc6-4743-b20d-568b424728a5]# cd ../4b241ea0-43aa-4f3b-ab7d-2fc633b491a1/[root@ovmserver1 4b241ea0-43aa-4f3b-ab7d-2fc633b491a1]# ls -ltotal 5568076-rwxr----- 1 36 36 107374182400 Oct 31  2012 9020f2e1-7b8a-4641-8f80-749768cc237a-rw-rw---- 1 36 36          341 Oct 31  2012 9020f2e1-7b8a-4641-8f80-749768cc237a.meta[root@ovmserver1 4b241ea0-43aa-4f3b-ab7d-2fc633b491a1]# file 9020f2e1-7b8a-4641-8f80-749768cc237a9020f2e1-7b8a-4641-8f80-749768cc237a: x86 boot sector; partition 1: ID=0x83, active, starthead 1, startsector 63, 401562 sectors; partition 2: ID=0x82, starthead 0, startsector 401625, 65529135 sectors; startsector 63, 401562 sectors; partition 2: ID=0x82, starthead 0, startsector 401625, 65529135 sectors; partition 3: ID=0x83, starthead 254, startsector 65930760, 8385930 sectors; partition 4: ID=0x5, starthead 254, startsector 74316690, 135395820 sectors, code offset 0x48 9020f2e1-7b8a-4641-8f80-749768cc237a is the second exported disk, with partition 1 bootable 3. Prepare the new guest on Oracle VM. By Ovm-Manager we can prepare the guest where we will move the exported virtual-disks; under the Tab "Servers and VMs": click on  and create your guest with parameters collected before (point 1): - add NICs on different networks: - add virtual-disks; in this case we add two disks of 1.0 GB each one; we will extend the virtual disk copying the source KVM virtual-disk ( see next steps ) - verify virtual-disks created ( under Repositories tab ) 4. Verify OVM virtual-disks names. [root@ovmserver1 VirtualMachines]# grep -r hyptest_rdbms * 0004fb0000060000a906b423f44da98e/vm.cfg:OVM_simple_name = 'hyptest_rdbms' [root@ovmserver1 VirtualMachines]# cd 0004fb0000060000a906b423f44da98e [root@ovmserver1 0004fb0000060000a906b423f44da98e]# more vm.cfgvif = ['mac=00:21:f6:0f:3f:85,bridge=0004fb001089128', 'mac=00:21:f6:0f:3f:8e,bridge=0004fb00101971d'] OVM_simple_name = 'hyptest_rdbms' vnclisten = '127.0.0.1' disk = ['file:/OVS/Repositories/0004fb00000300004f17b7368139eb41/ VirtualDisks/0004fb000012000097c1bfea9834b17d.img,xvda,w', 'file:/OVS/Repositories/0004fb00000300004f17b7368139eb41/VirtualDisks/ 0004fb0000120000cde6a11c3cb1d0be.img,xvdb,w'] vncunused = '1' uuid = '0004fb00-0006-0000-a906-b423f44da98e' on_reboot = 'restart' cpu_weight = 27500 memory = 32768 cpu_cap = 0 maxvcpus = 8 OVM_high_availability = True maxmem = 32768 vnc = '1' OVM_description = '' on_poweroff = 'destroy' on_crash = 'restart' name = '0004fb0000060000a906b423f44da98e' guest_os_type = 'linux' builder = 'hvm' vcpus = 8 keymap = 'en-us' OVM_os_type = 'Oracle Linux 5' OVM_cpu_compat_group = '' OVM_domain_type = 'xen_hvm' disk2 ovm ==> /OVS/Repositories/0004fb00000300004f17b7368139eb41/VirtualDisks/ 0004fb0000120000cde6a11c3cb1d0be.img disk1 ovm ==> /OVS/Repositories/0004fb00000300004f17b7368139eb41/VirtualDisks/ 0004fb000012000097c1bfea9834b17d.img Summarizing disk1 --source ==> /mnt/b8296fca-13c4-4841-a50f-773b5139fcee/images/4b241ea0-43aa-4f3b-ab7d-2fc633b491a1/9020f2e1-7b8a-4641-8f80-749768cc237a disk1 --dest ==> /OVS/Repositories/0004fb00000300004f17b7368139eb41/VirtualDisks/ 0004fb000012000097c1bfea9834b17d.img disk2 --source ==> /mnt/b8296fca-13c4-4841-a50f-773b5139fcee/images/d4ef928d-6dc6-4743-b20d-568b424728a5/4c03b1cf-67cc-4af0-ad1e-529fd665dac1 disk2 --dest ==> /OVS/Repositories/0004fb00000300004f17b7368139eb41/VirtualDisks/ 0004fb0000120000cde6a11c3cb1d0be.img 5. Copy KVM exported virtual-disks to OVM virtual-disks. Keeping your Oracle VM guest stopped you can copy KVM exported virtual-disks to OVM virtual-disks; what I did is only to locally mount the filesystem containing the exported virtual-disk ( by an usb device ) on my OVS; the copy automatically resize OVM virtual-disks ( previously created with a size of 1GB ) . nohup cp /mnt/b8296fca-13c4-4841-a50f-773b5139fcee/images/4b241ea0-43aa-4f3b-ab7d-2fc633b491a1/9020f2e1-7b8a-4641-8f80-749768cc237a /OVS/Repositories/0004fb00000300004f17b7368139eb41/VirtualDisks/0004fb000012000097c1bfea9834b17d.img & nohup cp /mnt/b8296fca-13c4-4841-a50f-773b5139fcee/images/d4ef928d-6dc6-4743-b20d-568b424728a5/4c03b1cf-67cc-4af0-ad1e-529fd665dac1 /OVS/Repositories/0004fb00000300004f17b7368139eb41/VirtualDisks/0004fb0000120000cde6a11c3cb1d0be.img & 7. When copy completed refresh repository to aknowledge the new-disks size. 7. After "refresh repository" is completed, start guest machine by Oracle VM manager. After the first start of your guest: - verify that you can see all disks and partitions - verify that your guest is network reachable ( MAC Address of your NICs changed ) Eventually you can also evaluate to convert your guest to PVM ( Paravirtualized virtual Machine ) following official Oracle documentation. Ciao Simon COTER ps: next-time I'd like to post an article reporting how to manually migrate Virtual-Iron guests to OracleVM.  Comments and corrections are welcome. 

    Read the article

  • Suggestions for splitting server roles amongst Hyper-V virtual servers / RAID6 or RAID10? / AppAssure

    - by Anon
    We have 2 Hyper-V hosts at present running 1 virtual server that was converted from a physical box running all roles. My plan is to split the roles over various virtual machines, upgrading to the latest software versions as I go, and use the backup server as a standby in case the main server fails. AppAssure backup software has a feature called Virtual Standby, so the VHD's can be ready to be fired up on the backup server if necessary. Off-site backups will be done via external USB drive for now. I'm just seeking some input/suggestions into how I'm planning to split the roles out amongst various virtual servers. Also, I'm curious how to setup the storage on the servers. We do not have any NAS's, SAN'S or any budget for this. What would the best RAID level be to use? I'm thinking either RAID6 (which is currently used) however I'm concerned about the write speeds, or RAID10 but again I'm worried that I can only lose 1 drive (from the same mirror) as opposed to any 2 with RAID6. I realise I have a hot swap for this, but what if a further drive fails during a rebuild? Is the write penalty of RAID6 worth the extra reliability over RAID10? Or will it be too slow with all the roles I am planning, therefore RAID10 is my only real option? The reason for the needed redundancy is I am the only technician and I'm not always on-site. Options I've considered: 1) 5 drives in RAID6 set, 200gb for host OS, rest for VM storage. 1 drive for hot swap - this is how it is currently setup 2) 4 drives in RAID10 set, 200gb for host OS, rest for VM storage. 2 drives for hot swap 3) 4 drives in RAID10 set for VM storage, 2 drives in RAID1 set for host OS. No drives for hot swap - While this is probably the best option with the amount of drives I have, I don't like the idea of having no hot swap 4) 3 drives in RAID6 set for VM storage, 2 drives in RAID1 set for host OS. 1 drive for hot swap All options give us enough storage capacity for our files, etc. We don't have any budget for extra drives or extra hot swap HD chassis for the servers. We have about 70 clients and about 150 users. MAIN SERVER Intel Xeon 5520 @ 2.27 GHz (2 processors) 16GB RAM 6 x 1TB Seagate Barracuda ES.2 Enterprise SATA drives Intel SRCSATAWB RAID controller Virtual machine workload using Hyper-V on Windows Server 2008 R2: DC01 - Active Directory Domain Controller / DNS server / Global catalog - 1GB RAM DC02 - Active Directory Domain Controller / DNS server / Global catalog - 1GB RAM Member Server - DHCP server, File server, Print server - 1GB RAM SCCM Member Server - 4GB RAM Third Party Software Member Server - A/V server, Ticketing software, etc - 4GB RAM Exchange 2007 - 4GB RAM - however we are probably migrating to a hosted solution, therefore freeing up resources BACKUP SERVER Intel Xeon E5410 @ 2.33GHz (2 processors) 16GB RAM 6 x 2TB WD RE4 SATA drives Intel SRCSASRB RAID controller Virtual machine workload using Hyper-V on Windows Server 2008 R2: AppAssure backup software - 8GB RAM

    Read the article

  • Tips For Finding a Professional SEO Consultant

    There are some basic tips to finding a professional SEO consultant to drive traffic to your website, and implementing those tips means you're less likely to suffer financially. Whether you have an established online business, blog, or website you need to make sure you consider search engine optimization to drive a continual stream of new, targeted traffic to your site while getting the best possible results in the search engine results pages.

    Read the article

  • Can You Get Recovered Data From Wet Hard Drives?

    Most of us are aware of the fact that it is not recommended to have water and your hard drive connect with each other. The protective hard casing of your hard drive is not designed to withstand conta... [Author: Michiel Van Kets - Computers and Internet - May 08, 2010]

    Read the article

  • Raid1 with active and spare partition

    - by Daniel Baron
    I am having the following problem with a RAID1 software raid partition on my Ubuntu system (10.04 LTS, 2.6.32-24-server in case it matters). One of my disks (sdb5) reported I/O errors and was therefore marked faulty in the array. The array was then degraded with one active device. Hence, I replaced the harddisk, cloned the partition table and added all new partitions to my raid arrays. After syncing all partitions ended up fine, having 2 active devices - except one of them. The partition which reported the faulty disk before, however, did not include the new partition as an active device but as a spare disk: md3 : active raid1 sdb5[2] sda5[1] 4881344 blocks [2/1] [_U] A detailed look reveals: root@server:~# mdadm --detail /dev/md3 [...] Number Major Minor RaidDevice State 2 8 21 0 spare rebuilding /dev/sdb5 1 8 5 1 active sync /dev/sda5 So here is the question: How do I tell my raid to turn the spare disk into an active one? And why has it been added as a spare device? Recreating or reassembling the array is not an option, because it is my root partition. And I can not find any hints to that subject in the Software Raid HOWTO. Any help would be appreciated. Current Solution I found a solution to my problem, but I am not sure that this is the actual way to do it. Having a closer look at my raid I found that sdb5 was always listed as a spare device: mdadm --examine /dev/sdb5 [...] Number Major Minor RaidDevice State this 2 8 21 2 spare /dev/sdb5 0 0 0 0 0 removed 1 1 8 5 1 active sync /dev/sda5 2 2 8 21 2 spare /dev/sdb5 so readding the device sdb5 to the array md3 always ended up in adding the device as a spare. Finally I just recreated the array mdadm --create /dev/md3 --level=1 -n2 -x0 /dev/sda5 /dev/sdb5 which worked. But the question remains open for me: Is there a better way to manipulate the summaries in the superblock and to tell the array to turn sdb5 from a spare disk to an active disk? I am still curious for an answer.

    Read the article

  • Organization &amp; Architecture UNISA Studies &ndash; Chap 4

    - by MarkPearl
    Learning Outcomes Explain the characteristics of memory systems Describe the memory hierarchy Discuss cache memory principles Discuss issues relevant to cache design Describe the cache organization of the Pentium Computer Memory Systems There are key characteristics of memory… Location – internal or external Capacity – expressed in terms of bytes Unit of Transfer – the number of bits read out of or written into memory at a time Access Method – sequential, direct, random or associative From a users perspective the two most important characteristics of memory are… Capacity Performance – access time, memory cycle time, transfer rate The trade off for memory happens along three axis… Faster access time, greater cost per bit Greater capacity, smaller cost per bit Greater capacity, slower access time This leads to people using a tiered approach in their use of memory   As one goes down the hierarchy, the following occurs… Decreasing cost per bit Increasing capacity Increasing access time Decreasing frequency of access of the memory by the processor The use of two levels of memory to reduce average access time works in principle, but only if conditions 1 to 4 apply. A variety of technologies exist that allow us to accomplish this. Thus it is possible to organize data across the hierarchy such that the percentage of accesses to each successively lower level is substantially less than that of the level above. A portion of main memory can be used as a buffer to hold data temporarily that is to be read out to disk. This is sometimes referred to as a disk cache and improves performance in two ways… Disk writes are clustered. Instead of many small transfers of data, we have a few large transfers of data. This improves disk performance and minimizes processor involvement. Some data designed for write-out may be referenced by a program before the next dump to disk. In that case the data is retrieved rapidly from the software cache rather than slowly from disk. Cache Memory Principles Cache memory is substantially faster than main memory. A caching system works as follows.. When a processor attempts to read a word of memory, a check is made to see if this in in cache memory… If it is, the data is supplied, If it is not in the cache, a block of main memory, consisting of a fixed number of words is loaded to the cache. Because of the phenomenon of locality of references, when a block of data is fetched into the cache, it is likely that there will be future references to that same memory location or to other words in the block. Elements of Cache Design While there are a large number of cache implementations, there are a few basic design elements that serve to classify and differentiate cache architectures… Cache Addresses Cache Size Mapping Function Replacement Algorithm Write Policy Line Size Number of Caches Cache Addresses Almost all non-embedded processors support virtual memory. Virtual memory in essence allows a program to address memory from a logical point of view without needing to worry about the amount of physical memory available. When virtual addresses are used the designer may choose to place the cache between the MMU (memory management unit) and the processor or between the MMU and main memory. The disadvantage of virtual memory is that most virtual memory systems supply each application with the same virtual memory address space (each application sees virtual memory starting at memory address 0), which means the cache memory must be completely flushed with each application context switch or extra bits must be added to each line of the cache to identify which virtual address space the address refers to. Cache Size We would like the size of the cache to be small enough so that the overall average cost per bit is close to that of main memory alone and large enough so that the overall average access time is close to that of the cache alone. Also, larger caches are slightly slower than smaller ones. Mapping Function Because there are fewer cache lines than main memory blocks, an algorithm is needed for mapping main memory blocks into cache lines. The choice of mapping function dictates how the cache is organized. Three techniques can be used… Direct – simplest technique, maps each block of main memory into only one possible cache line Associative – Each main memory block to be loaded into any line of the cache Set Associative – exhibits the strengths of both the direct and associative approaches while reducing their disadvantages For detailed explanations of each approach – read the text book (page 148 – 154) Replacement Algorithm For associative and set associating mapping a replacement algorithm is needed to determine which of the existing blocks in the cache must be replaced by a new block. There are four common approaches… LRU (Least recently used) FIFO (First in first out) LFU (Least frequently used) Random selection Write Policy When a block resident in the cache is to be replaced, there are two cases to consider If no writes to that block have happened in the cache – discard it If a write has occurred, a process needs to be initiated where the changes in the cache are propagated back to the main memory. There are several approaches to achieve this including… Write Through – all writes to the cache are done to the main memory as well at the point of the change Write Back – when a block is replaced, all dirty bits are written back to main memory The problem is complicated when we have multiple caches, there are techniques to accommodate for this but I have not summarized them. Line Size When a block of data is retrieved and placed in the cache, not only the desired word but also some number of adjacent words are retrieved. As the block size increases from very small to larger sizes, the hit ratio will at first increase because of the principle of locality, which states that the data in the vicinity of a referenced word are likely to be referenced in the near future. As the block size increases, more useful data are brought into cache. The hit ratio will begin to decrease as the block becomes even bigger and the probability of using the newly fetched information becomes less than the probability of using the newly fetched information that has to be replaced. Two specific effects come into play… Larger blocks reduce the number of blocks that fit into a cache. Because each block fetch overwrites older cache contents, a small number of blocks results in data being overwritten shortly after they are fetched. As a block becomes larger, each additional word is farther from the requested word and therefore less likely to be needed in the near future. The relationship between block size and hit ratio is complex, and no set approach is judged to be the best in all circumstances.   Pentium 4 and ARM cache organizations The processor core consists of four major components: Fetch/decode unit – fetches program instruction in order from the L2 cache, decodes these into a series of micro-operations, and stores the results in the L2 instruction cache Out-of-order execution logic – Schedules execution of the micro-operations subject to data dependencies and resource availability – thus micro-operations may be scheduled for execution in a different order than they were fetched from the instruction stream. As time permits, this unit schedules speculative execution of micro-operations that may be required in the future Execution units – These units execute micro-operations, fetching the required data from the L1 data cache and temporarily storing results in registers Memory subsystem – This unit includes the L2 and L3 caches and the system bus, which is used to access main memory when the L1 and L2 caches have a cache miss and to access the system I/O resources

    Read the article

  • Fail to start windows after Ubuntu 11.10 install

    - by user49995
    Computer: HP Pavilion dv7-6140eo OS: Originally Win7 I recently decided to try out Ubuntu, and I decided to dual-boot it with Windows 7. First I googled some how-to's, then I downloaded Ubuntu onto a memory stick and made a second partition (I originally only had one partition that I shrunk and used the unallocated space to install onto during the Ubuntu install). During the install I set format type to xt4 (or something, it was the default option), chose the "in the beginning" option and set the last option as "\". The install was successful. Although, when I restarted my computer I weren't able to choose which operating system to start; it went right into windows. After showing the windows logo for half a second before rebooting, I get a blue screen (see bottom of the page). Trying to fix it, I deleted the newly made partition I had just installed Ubuntu onto (seeing it wasn't working either). This made no difference. I proceeded with installing Ubuntu again, so I would at least have a functioning computer, and now Ubuntu works fine (on it now). The only difference on start-up is that I get a Grub window asking me to between several options including Linux and Windows 7 (loader). Now, if I choose Windows 7, I get the message "Windows was unable to start. A recent software or hardware change might be the cause". It recommends me to choose the first option of the two it provides; to start start-up repair tool. The second option being starting windows normally. If I start windows normally, the same thing happens as earlier. My computer does not have a windows installation CD. Although, it has (at least it used to, if I haven't screwed that too up) a 17gb recovery partition. In addition I made an image of the computer onto a external hard drive when I first got it. Though, I have no idea how to use either. If anyone has any idea how I can make windows work again or reinstall it (already backed up my files) it would be greatly appreciated. I still prefer to dual boot between the two functioning operating systems, but I will settle for a functioning windows 7. Thanks a lot for any replies. Blue screen: A problem has been detected and Windows has been shut down to prevent damage to your computer. If this is the first time you've seen this Stop error screen, restart your computer. If this screen appears again, follow these steps: Check for viruses on your computer. Remove and newly installed hard drives or hard drive controllers. Check your hard drive to make sure it is properly configures and terminated. Run CMKDSK /F to check for hard drive corruption, and then restart your computer. Technical information: **STOP: 0x0000007B (0xFFFFF880009A97E8,0xFFFFFFFFC0000034, 0x0000000000000000,0x0000000000000000

    Read the article

  • Windows Server 2008 Software Raid 5 - Data integrity issues

    - by Fopedush
    I've got a server running Windows Server 2008 R2, with a (windows native) software raid-5 array. The array consists of 7x 1TB Western Digital RE3 and RE4 drives. I have offline backups of this array. The problem is this: I noticed a few days ago after copying a large file to the disk that there was an integrity issue with that file - it was a ~12GB file that I had downloaded via uTorrent. After moving it to the raid array, I used uTorrent to relocate the download location, and performed a re-check so I could seed it from that location. The recheck found that only 6308/6310 chunks of the copied file were intact. My next step was to write a quick powershell script that would copy files to the array, while performing a SHA1 hash of the original and resultant files and comparing them. Smaller files (100-1000MB) copied over just fine. When I started copying larger data (~15GB), I found that the hash check failed about 2/3rds of the time. The corrupt files had very, very small inconsistencies - less than .01%. I further eliminated the possibility of networking or client issues by placing this large file on the C:\ of the server, and copying it repeatedly from there to the array, seeing similar results. Copying the data via explorer, powershell, or the standard windows command prompt yield the same results. None of the copies fail or report any problems. The raid array itself is listed as healthy in disk management. After a few experiments, I shut down the server and ran memtest overnight. No errors were detected. A basic run of chkdsk found no problems, but I did not use the /R flag, as I was unsure how that might affect a software raid-5 volume. I next ran Crystal Disk Info to check the smart data on the drives - but found that CDI only detected 5 out of 7 of the disks in the array. I have no idea why. Nevertheless, CDI shows the following "caution" flags on a single one of the drives: 05 199 199 140 000000000001 Reallocated Sectors Count C5 200 200 __0 000000000001 Current Pending Sector Count Which is a little bit alarming, but I don't really know what to do with the information. I hardly feel like one reallocated sector could be causing this. At this point, I'm looking for some guidance on what to do next. I need to determine the cause of this issue, but I'm hesitant to run chkdsk /R or any bootable disk health checkers because I'm afraid they might break the array. I've considered triggering a re-sync of the array, but I'm not actually sure how to do that without doing something silly like manually dropping a disk and then restoring it. Any advice that could help me ferret out the precise cause of this issue would be greatly appreciated.

    Read the article

< Previous Page | 239 240 241 242 243 244 245 246 247 248 249 250  | Next Page >