Search Results

Search found 6875 results on 275 pages for 'crash reports'.

Page 252/275 | < Previous Page | 248 249 250 251 252 253 254 255 256 257 258 259  | Next Page >

  • Profiling Startup Of VS2012 &ndash; SpeedTrace Profiler

    - by Alois Kraus
    SpeedTrace is a relatively unknown profiler made a company called Ipcas. A single professional license does cost 449€+VAT. For the test I did use SpeedTrace 4.5 which is currently Beta. Although it is cheaper than dotTrace it has by far the most options to influence how profiling does work. First you need to create a tracing project which does configure tracing for one process type. You can start the application directly from the profiler or (much more interesting) it does attach to a specific process when it is started. For this you need to check “Trace the specified …” radio button and enter the process name in the “Process Name of the Trace” edit box. You can even selectively enable tracing for processes with a specific command line. Then you need to activate the trace project by pressing the Activate Project button and you are ready to start VS as usual. If you want to profile the next 10 VS instances that you start you can set the Number of Processes counter to e.g. 10. This is immensely helpful if you are trying to profile only the next 5 started processes. As you can see there are many more tabs which do allow to influence tracing in a much more sophisticated way. SpeedTrace is the only profiler which does not rely entirely on the profiling Api of .NET. Instead it does modify the IL code (instrumentation on the fly) to write tracing information to disc which can later be analyzed. This approach is not only very fast but it does give you unprecedented analysis capabilities. Once the traces are collected they do show up in your workspace where you can open the trace viewer. I do skip the other windows because this view is by far the most useful one. You can sort the methods not only by Wall Clock time but also by CPU consumption and wait time which none of the other products support in their views at the same time. If you want to optimize for CPU consumption sort by CPU time. If you want to find out where most time is spent you need Clock Total time and Clock Waiting. There you can directly see if the method did take long because it did wait on something or it did really execute stuff that did take so long. Once you have found a method you want to drill deeper you can double click on a method to get to the Caller/Callee view which is similar to the JetBrains Method Grid view. But this time you do see much more. In the middle is the clicked method. Above are the methods that call you and below are the methods that you do directly call. Normally you would then start digging deeper to find the end of the chain where the slow method worth optimizing is located. But there is a shortcut. You can press the magic   button to calculate the aggregation of all called methods. This is displayed in the lower left window where you can see each method call and how long it did take. There you can also sort to see if this call stack does only contain methods (e.g. WCF connect calls which you cannot make faster) not worth optimizing. YourKit has a similar feature where it is called Callees List. In the Functions tab you have in the context menu also many other useful analysis options One really outstanding feature is the View Call History Drilldown. When you select this one you get not a sum of all method invocations but a list with the duration of each method call. This is not surprising since SpeedTrace does use tracing to get its timings. There you can get many useful graphs how this method did behave over time. Did it become slower at some point in time or was only the first call slow? The diagrams and the list will tell you that. That is all fine but what should I do when one method call was slow? I want to see from where it was coming from. No problem select the method in the list hit F10 and you get the call stack. This is a life saver if you e.g. search for serialization problems. Today Serializers are used everywhere. You want to find out from where the 5s XmlSerializer.Deserialize call did come from? Hit F10 and you get the call stack which did invoke the 5s Deserialize call. The CPU timeline tab is also useful to find out where long pauses or excessive CPU consumption did happen. Click in the graph to get the Thread Stacks window where you can get a quick overview what all threads were doing at this time. This does look like the Stack Traces feature in YourKit. Only this time you get the last called method first which helps to quickly see what all threads were executing at this moment. YourKit does generate a rather long list which can be hard to go through when you have many threads. The thread list in the middle does not give you call stacks or anything like that but you see which methods were found most often executing code by the profiler which is a good indication for methods consuming most CPU time. This does sound too good to be true? I have not told you the best part yet. The best thing about this profiler is the staff behind it. When I do see a crash or some other odd behavior I send a mail to Ipcas and I do get usually the next day a mail that the problem has been fixed and a download link to the new version. The guys at Ipcas are even so helpful to log in to your machine via a Citrix Client to help you to get started profiling your actual application you want to profile. After a 2h telco I was converted from a hater to a believer of this tool. The fast response time might also have something to do with the fact that they are actively working on 4.5 to get out of the door. But still the support is by far the best I have encountered so far. The only downside is that you should instrument your assemblies including the .NET Framework to get most accurate numbers. You can profile without doing it but then you will see very high JIT times in your process which can severely affect the correctness of the measured timings. If you do not care about exact numbers you can also enable in the main UI in the Data Trace tab logging of method arguments of primitive types. If you need to know what files at which times were opened by your application you can find it out without a debugger. Since SpeedTrace does read huge trace files in its reader you should perhaps use a 64 bit machine to be able to analyze bigger traces as well. The memory consumption of the trace reader is too high for my taste. But they did promise for the next version to come up with something much improved.

    Read the article

  • PASS: Board Q&amp;A at the Summit

    - by Bill Graziano
    The last two years we’ve put the Board in front of the members and taken questions.  We’re going to do that again this year.  It will be in Room 307/308 from 12:15 to 1:30 on Friday. Yes, this time overlaps with the Birds of a Feather Lunch and the start of afternoon sessions – but only partially.  You can attend the Q&A and still get to parts of both of those.  There just isn’t a great time to do this.  Every time overlaps with something. We can’t do it after the last session on Friday.  We can’t fit it between the last session and the evening events on Wednesday or Thursday.  We had some discussion around breakfast time but I didn’t think that was realistic.  This is the least bad time we could come up with. Last year we had 60-70 people attend.  These are the items that were specific things that I could work on: The first question was whether to increase transparency around individual votes of Board members.  We approved this at the Board meeting the following day.  The only caveat was that if the Board is given confidential information as a basis for their vote then we may not be able to disclose individual votes.  Putting a Director in a position where they can’t publicly defend the reason for their vote is a difficult situation.  Thanks Kendal! Can we have a Board member discretionary fund?  As background, I took a couple of people to lunch so we could have a quiet place to talk.  I bought lunch but wasn’t able to expense it back to PASS.  We just don’t have a budget item for things like this.  I think we should.  I would guess the entire Board would like it also.  It was in an earlier version of the budget but came out as part of a cost-cutting move to balance the budget.  I’d like to see it added back in but we’ll have to see. I know there were a comments about the elections.  At this point we had created the Election Review Committee.  I’ve already written at length about this process. Where does IT work go?  PASS started to publish our internal management reports starting in December 2010.  You can find them on our Governance page.  These aren’t filtered at all and include a variety of information about IT projects.  The most recent update had roughly a page of updates related to IT.  Lots of the work was related to Summit and the Orator tool that we use to manage speaker submissions. There were numerous requests that Tina Turner not be repeated.  Done.  I don’t think we’ll do anything quite like that again.  We had a request for a payment plan for Summit.  We looked into this briefly but didn’t take any action.  We didn’t think the effort was worth the small number of people that would use it.  If you disagree, submit this on our Summit Feedback site and get some votes. There were lots of suggestions around the first-timers events – especially from first timers.  You can find all our current activities related to first-timers at the First Timers page on the Summit web site.  Plus links to 34 (!) blog posts on suggestions for first-timers.  And a big THANK YOU to Confio and Red Gate for sponsoring this. I hope you get the chance to attend.  These events are very helpful to me as a Board member.  I like being able to look around the room as comments are being made and see the audience reaction.  It helps me gauge the interest in an idea. I’d also like to direct you to the Summit Feedback site.  You can submit and vote on ideas to make the Summit a better experience.  As of right now we have the suggestions from last year still up.  We may reset these prior to the Summit though.

    Read the article

  • Process Centric Banking: Loan Origination Solution

    - by Manish Palaparthy
    There is an old proverb that goes, "The difference between theory and practice is greater in practice than in theory". So, we keep doing numerous "Proof of Concepts" with our own products on various business cases to analyze them deeply, understand and explain to our customers. We then present our learnings as they happened. The awareness of each PoC should help readers increase the trustworthiness of the results coming out of these PoCs. I present one such PoC where we invested a lot of time&effort.  Process Centric Banking : Loan Origination Solution Loan Origination is a process by which a borrower applies for a new loan and the lender processes that application. Loan origination includes the series of steps taken by the bank from the point the customer shows interest in a loan product all the way to disbursal of funds. The Loan Origination process is relevant for many kind of lenders in Financial services: Banks, Credit Unions, NBFCs(Non Banking Financial Companies) and so on. For simplicity sake, I will use "Bank" as the lending institution in the rest of my article.  Loan Origination is one of the core processes for Banks as it is the process by which the it creates assets against which the Institution earns most of its profits from. A well tuned loan origination process can affect the Bank in many positive ways. Banks have always shown great interest in automating the loan origination process for the above reason. However, due the constant changes in customer environment, market dynamics, prevailing economic conditions, cost pressures & regulatory environment they run into lot of challenges. Let me categorize some of these challenges for you Customer Environment Multiple Channels: Customer can use any of the available channels (Internet Banking, Email, Fax, Branch, Phone Banking, ATM, Broker, Mobile, Snail Mail) to perform all or some of the activities related to her Visibility into the origination process: Expect immediate update on the status of loan processing & alert messages Reduced Turn Around Time: Expect loans to be processed with least turn around time Reduced loan processing fees: Partly due to market dynamics the customer expects the loan processing fee to be negligible Market Dynamics Competitive environment:  The competition keeps creating many variants of loan products to attract customers, the bank needs to create similar product variants with better offers to attract customers or keep existing ones Ability to migrate loans from one vendor to another: It has become really easy for retail customers to move from one bank to the other given the low fee of loan processing and highly attractive offers. How does the bank protect it's customer base while actively engaging with potential customers banking with competitor banks Flexibility to react to market developments: Market development greatly influence loan processing, underwriting, asset valuation, risk mitigation rules. Can the bank modify rules and policies, the idea is not just to react to market developments but to pro-actively manage new developments Economic conditions Constant change in various rates and their implications on the rates and rules applied when on-boarding a loan: How quickly can the bank apply changes to rates offered to customers when the central bank changes various rates Requirements of Audit by the central banker: Tough economic conditions have demanded much more stringent audit rules and tests. The banks needs to produce ready reports(historic & operational) for audit compliance Risk Mitigation: While risk mitigation has always been a key concern for the bank, this is the area where the bank's underwriters & risk analysts spend the maximum time when processing a loan application. In order to reduce TAT the bank cannot compromise on its risk mitigation strategies Cost pressures Reduce Cost of processing per application: To deliver a reduced loan processing fee to the customer, the bank needs to keep its cost per processing loan application low. Meet customer TAT expectations while reducing the queues and the systems being used to process the loan application: The loan application could potentially be spending a lot of time waiting in the queue for further processing. Different volumes & patterns of applications demand different queuing algorithms. The bank needs to have real-time visibility into these queues and have the flexibility to change queuing algorithms at runtime  Increase the use of electronic communication and reduce the branch channel usage: Lesser automation leads not only leads to Increased turn around time, it also impacts more costs to reach out to customers The objective of our PoC was to implement a Loan Origination Solution whose ownership lies with the bank and effectively meet the challenges listed above. We built a simple story board for the solution We then went about implementing our storyboard using Oracle BPM Suite, Webcenter Content : Imaging. The web UI has been built on ADF technolgies, while the integration with core-services has been implemented using the underlying SOA infrastructure. The BPM process model is quite exhaustive can meet all the challenges listed above to reasonable degree. A bank intending to implement an end-to-end Loan Origination Solution has multiple options at it's disposal. It can Develop a customer Loan Origination Application from scratch: Gives maximum opportunity to build what you want but inflexible to upgrade and maintain. Higher TCO in long term Buy a Packaged application & customize it: Customizing a generic loan application can be tedious and prove as difficult as above. Build it using many disparate & un-integrated tools: Initially seems easier than developing from scratch. But, without integrated tool sets this is not a viable approach either or A solution based on a Framework: Independent Services and Business Process Modeling provide decoupled architecture that is flexible. We built this framework end-to-end with processes the core process of loan origination & several sub-processes such as Analyse and define customer needs, customer credit verification, identity check processes, legal review process, New customer registration & risk assessment.

    Read the article

  • Turning on collision crashes game

    - by MomentumGaming
    I am getting a null pointer excecption to both my sprite and level. I am working on my mob class, and when I try to move him and the move function is called, the game crashes after checking collision with a null pointer excecption. Taking out the one line that actually checks if the tile located in front of it fixes the problem. Also, if i keep collision ON but don't move the position of the mob (the spider) the game works fine. I will have collision, and the spider appears on the screen, only problem is, getting it to move causes this nasty error that i just can't fix. true Exception in thread "Display" java.lang.NullPointerException at com.apcompsci.game.entity.mob.Mob.collision(Mob.java:67) at com.apcompsci.game.entity.mob.Mob.move(Mob.java:38) at com.apcompsci.game.entity.mob.spider.update(spider.java:58) at com.apcompsci.game.level.Level.update(Level.java:55) at com.apcompsci.game.Game.update(Game.java:128) at com.apcompsci.game.Game.run(Game.java:106) at java.lang.Thread.run(Unknown Source) Here is my renderMob mehtod: public void renderMob(int xp,int yp,Sprite sprite,int flip) { xp -= xOffset; yp-=yOffset; for(int y = 0; y<32; y++) { int ya = y + yp; int ys = y; if(flip == 2||flip == 3)ys = 31-y; for(int x = 0; x<32; x++) { int xa = x + xp; int xs = x; if(flip == 1||flip == 3)xs = 31-x; if(xa < -32 || xa >=width || ya<0||ya>=height) break; if(xa<0) xa =0; int col = sprite.pixels[xs+ys*32]; if(col!= 0x000000) pixels[xa+ya*width] = col; } } } My spider class which determines the sprite and where I control movement, also rendering the spider onto the screen, when I increment ya to move the sprite, I get the crash, but without ya++, it runs flawlessly with a spider sprite on screen: package com.apcompsci.game.entity.mob; import com.apcompsci.game.entity.mob.Mob.Direction; import com.apcompsci.game.graphics.Screen; import com.apcompsci.game.graphics.Sprite; import com.apcompsci.game.level.Level; public class spider extends Mob{ Direction dir; private Sprite sprite; private boolean walking; public spider(int x, int y) { this.x = x <<4; this.y = y <<4; sprite = sprite.spider_forward; } public void update() { int xa = 0, ya = 0; ya++; if(ya<0) { sprite = sprite.spider_forward; dir = Direction.UP; } if(ya>0) { sprite = sprite.spider_back; dir = Direction.DOWN; } if(xa<0) { sprite = sprite.spider_side; dir = Direction.LEFT; } if(xa>0) { sprite = sprite.spider_side; dir = Direction.LEFT; } if(xa!= 0 || ya!= 0) { System.out.println("true"); move(xa,ya); walking = true; } else{ walking = false; } } public void render(Screen screen) { screen.renderMob(x, y, sprite, 0); } } This is th mob class that contains the move() method that is called in the spider class above. This move method calls the collision method. tile and sprite comes up null in the debugger: package com.apcompsci.game.entity.mob; import java.util.ArrayList; import java.util.List; import com.apcompsci.game.entity.Entity; import com.apcompsci.game.entity.projectile.DemiGodProjectile; import com.apcompsci.game.entity.projectile.Projectile; import com.apcompsci.game.graphics.Sprite; public class Mob extends Entity{ protected Sprite sprite; protected boolean moving = false; protected enum Direction { UP,DOWN,LEFT,RIGHT } protected Direction dir; public void move(int xa,int ya) { if(xa != 0 && ya != 0) { move(xa,0); move(0,ya); return; } if(xa>0) dir = Direction.RIGHT; if(xa<0) dir = Direction.LEFT; if(ya>0)dir = Direction.DOWN; if(ya<0)dir = Direction.UP; if(!collision(xa,ya)){ x+= xa; y+=ya; } } public void update() { } public void shoot(int x, int y, double dir) { //dir = Math.toDegrees(dir); Projectile p = new DemiGodProjectile(x, y,dir); level.addProjectile(p); } public boolean collision(int xa,int ya) { boolean solid = false; for(int c = 0; c<4; c++) { int xt = ((x+xa) + c % 2 * 14 - 8 )/16; int yt = ((y+ya) + c / 2 * 12 +3 )/16; if(level.getTile(xt, yt).solid()) solid = true; } return solid; } public void render() { } } Finally, here is the method in which i call the add() method for the spider to add it to the level: protected void loadLevel(String path) { try{ BufferedImage image = ImageIO.read(SpawnLevel.class.getResource(path)); int w = width =image.getWidth(); int h = height = image.getHeight(); tiles = new int[w*h]; image.getRGB(0, 0, w,h, tiles,0, w); } catch(IOException e){ e.printStackTrace(); System.out.println("Exception! Could not load level file!"); } add(new spider(20,45)); } I don't think i need to include the level class but just in case, I have provided a gistHub link for better context. It contains all of the full classes listed above , plus my entity class and maybe another. Thanks for the help if you decide to do so, much appreciated! Also, please tell me if i'm in the wrong section of stackeoverflow, i figured that since this is the gamign section that it belonged but debugging code normally goes into the general section.

    Read the article

  • Benchmarking MySQL Replication with Multi-Threaded Slaves

    - by Mat Keep
    0 0 1 1145 6530 Homework 54 15 7660 14.0 Normal 0 false false false EN-US JA X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:12.0pt; font-family:Cambria; mso-ascii-font-family:Cambria; mso-ascii-theme-font:minor-latin; mso-hansi-font-family:Cambria; mso-hansi-theme-font:minor-latin; mso-ansi-language:EN-US;} The objective of this benchmark is to measure the performance improvement achieved when enabling the Multi-Threaded Slave enhancement delivered as a part MySQL 5.6. As the results demonstrate, Multi-Threaded Slaves delivers 5x higher replication performance based on a configuration with 10 databases/schemas. For real-world deployments, higher replication performance directly translates to: · Improved consistency of reads from slaves (i.e. reduced risk of reading "stale" data) · Reduced risk of data loss should the master fail before replicating all events in its binary log (binlog) The multi-threaded slave splits processing between worker threads based on schema, allowing updates to be applied in parallel, rather than sequentially. This delivers benefits to those workloads that isolate application data using databases - e.g. multi-tenant systems deployed in cloud environments. Multi-Threaded Slaves are just one of many enhancements to replication previewed as part of the MySQL 5.6 Development Release, which include: · Global Transaction Identifiers coupled with MySQL utilities for automatic failover / switchover and slave promotion · Crash Safe Slaves and Binlog · Optimized Row Based Replication · Replication Event Checksums · Time Delayed Replication These and many more are discussed in the “MySQL 5.6 Replication: Enabling the Next Generation of Web & Cloud Services” Developer Zone article  Back to the benchmark - details are as follows. Environment The test environment consisted of two Linux servers: · one running the replication master · one running the replication slave. Only the slave was involved in the actual measurements, and was based on the following configuration: - Hardware: Oracle Sun Fire X4170 M2 Server - CPU: 2 sockets, 6 cores with hyper-threading, 2930 MHz. - OS: 64-bit Oracle Enterprise Linux 6.1 - Memory: 48 GB Test Procedure Initial Setup: Two MySQL servers were started on two different hosts, configured as replication master and slave. 10 sysbench schemas were created, each with a single table: CREATE TABLE `sbtest` (    `id` int(10) unsigned NOT NULL AUTO_INCREMENT,    `k` int(10) unsigned NOT NULL DEFAULT '0',    `c` char(120) NOT NULL DEFAULT '',    `pad` char(60) NOT NULL DEFAULT '',    PRIMARY KEY (`id`),    KEY `k` (`k`) ) ENGINE=InnoDB DEFAULT CHARSET=latin1 10,000 rows were inserted in each of the 10 tables, for a total of 100,000 rows. When the inserts had replicated to the slave, the slave threads were stopped. The slave data directory was copied to a backup location and the slave threads position in the master binlog noted. 10 sysbench clients, each configured with 10 threads, were spawned at the same time to generate a random schema load against each of the 10 schemas on the master. Each sysbench client executed 10,000 "update key" statements: UPDATE sbtest set k=k+1 WHERE id = <random row> In total, this generated 100,000 update statements to later replicate during the test itself. Test Methodology: The number of slave workers to test with was configured using: SET GLOBAL slave_parallel_workers=<workers> Then the slave IO thread was started and the test waited for all the update queries to be copied over to the relay log on the slave. The benchmark clock was started and then the slave SQL thread was started. The test waited for the slave SQL thread to finish executing the 100k update queries, doing "select master_pos_wait()". When master_pos_wait() returned, the benchmark clock was stopped and the duration calculated. The calculated duration from the benchmark clock should be close to the time it took for the SQL thread to execute the 100,000 update queries. The 100k queries divided by this duration gave the benchmark metric, reported as Queries Per Second (QPS). Test Reset: The test-reset cycle was implemented as follows: · the slave was stopped · the slave data directory replaced with the previous backup · the slave restarted with the slave threads replication pointer repositioned to the point before the update queries in the binlog. The test could then be repeated with identical set of queries but a different number of slave worker threads, enabling a fair comparison. The Test-Reset cycle was repeated 3 times for 0-24 number of workers and the QPS metric calculated and averaged for each worker count. MySQL Configuration The relevant configuration settings used for MySQL are as follows: binlog-format=STATEMENT relay-log-info-repository=TABLE master-info-repository=TABLE As described in the test procedure, the slave_parallel_workers setting was modified as part of the test logic. The consequence of changing this setting is: 0 worker threads:    - current (i.e. single threaded) sequential mode    - 1 x IO thread and 1 x SQL thread    - SQL thread both reads and executes the events 1 worker thread:    - sequential mode    - 1 x IO thread, 1 x Coordinator SQL thread and 1 x Worker thread    - coordinator reads the event and hands it to the worker who executes 2+ worker threads:    - parallel execution    - 1 x IO thread, 1 x Coordinator SQL thread and 2+ Worker threads    - coordinator reads events and hands them to the workers who execute them Results Figure 1 below shows that Multi-Threaded Slaves deliver ~5x higher replication performance when configured with 10 worker threads, with the load evenly distributed across our 10 x schemas. This result is compared to the current replication implementation which is based on a single SQL thread only (i.e. zero worker threads). Figure 1: 5x Higher Performance with Multi-Threaded Slaves The following figure shows more detailed results, with QPS sampled and reported as the worker threads are incremented. The raw numbers behind this graph are reported in the Appendix section of this post. Figure 2: Detailed Results As the results above show, the configuration does not scale noticably from 5 to 9 worker threads. When configured with 10 worker threads however, scalability increases significantly. The conclusion therefore is that it is desirable to configure the same number of worker threads as schemas. Other conclusions from the results: · Running with 1 worker compared to zero workers just introduces overhead without the benefit of parallel execution. · As expected, having more workers than schemas adds no visible benefit. Aside from what is shown in the results above, testing also demonstrated that the following settings had a very positive effect on slave performance: relay-log-info-repository=TABLE master-info-repository=TABLE For 5+ workers, it was up to 2.3 times as fast to run with TABLE compared to FILE. Conclusion As the results demonstrate, Multi-Threaded Slaves deliver significant performance increases to MySQL replication when handling multiple schemas. This, and the other replication enhancements introduced in MySQL 5.6 are fully available for you to download and evaluate now from the MySQL Developer site (select Development Release tab). You can learn more about MySQL 5.6 from the documentation  Please don’t hesitate to comment on this or other replication blogs with feedback and questions. Appendix – Detailed Results

    Read the article

  • How to Identify Which Hardware Component is Failing in Your Computer

    - by Chris Hoffman
    Concluding that your computer has a hardware problem is just the first step. If you’re dealing with a hardware issue and not a software issue, the next step is determining what hardware problem you’re actually dealing with. If you purchased a laptop or pre-built desktop PC and it’s still under warranty, you don’t need to care about this. Have the manufacturer fix the PC for you — figuring it out is their problem. If you’ve built your own PC or you want to fix a computer that’s out of warranty, this is something you’ll need to do on your own. Blue Screen 101: Search for the Error Message This may seem like obvious advice, but searching for information about a blue screen’s error message can help immensely. Most blue screens of death you’ll encounter on modern versions of Windows will likely be caused by hardware failures. The blue screen of death often displays information about the driver that crashed or the type of error it encountered. For example, let’s say you encounter a blue screen that identified “NV4_disp.dll” as the driver that caused the blue screen. A quick Google search will reveal that this is the driver for NVIDIA graphics cards, so you now have somewhere to start. It’s possible that your graphics card is failing if you encounter such an error message. Check Hard Drive SMART Status Hard drives have a built in S.M.A.R.T. (Self-Monitoring, Analysis, and Reporting Technology) feature. The idea is that the hard drive monitors itself and will notice if it starts to fail, providing you with some advance notice before the drive fails completely. This isn’t perfect, so your hard drive may fail even if SMART says everything is okay. If you see any sort of “SMART error” message, your hard drive is failing. You can use SMART analysis tools to view the SMART health status information your hard drives are reporting. Test Your RAM RAM failure can result in a variety of problems. If the computer writes data to RAM and the RAM returns different data because it’s malfunctioning, you may see application crashes, blue screens, and file system corruption. To test your memory and see if it’s working properly, use Windows’ built-in Memory Diagnostic tool. The Memory Diagnostic tool will write data to every sector of your RAM and read it back afterwards, ensuring that all your RAM is working properly. Check Heat Levels How hot is is inside your computer? Overheating can rsult in blue screens, crashes, and abrupt shut downs. Your computer may be overheating because you’re in a very hot location, it’s ventilated poorly, a fan has stopped inside your computer, or it’s full of dust. Your computer monitors its own internal temperatures and you can access this information. It’s generally available in your computer’s BIOS, but you can also view it with system information utilities such as SpeedFan or Speccy. Check your computer’s recommended temperature level and ensure it’s within the appropriate range. If your computer is overheating, you may see problems only when you’re doing something demanding, such as playing a game that stresses your CPU and graphics card. Be sure to keep an eye on how hot your computer gets when it performs these demanding tasks, not only when it’s idle. Stress Test Your CPU You can use a utility like Prime95 to stress test your CPU. Such a utility will fore your computer’s CPU to perform calculations without allowing it to rest, working it hard and generating heat. If your CPU is becoming too hot, you’ll start to see errors or system crashes. Overclockers use Prime95 to stress test their overclock settings — if Prime95 experiences errors, they throttle back on their overclocks to ensure the CPU runs cooler and more stable. It’s a good way to check if your CPU is stable under load. Stress Test Your Graphics Card Your graphics card can also be stress tested. For example, if your graphics driver crashes while playing games, the games themselves crash, or you see odd graphical corruption, you can run a graphics benchmark utility like 3DMark. The benchmark will stress your graphics card and, if it’s overheating or failing under load, you’ll see graphical problems, crashes, or blue screens while running the benchmark. If the benchmark seems to work fine but you have issues playing a certain game, it may just be a problem with that game. Swap it Out Not every hardware problem is easy to diagnose. If you have a bad motherboard or power supply, their problems may only manifest through occasional odd issues with other components. It’s hard to tell if these components are causing problems unless you replace them completely. Ultimately, the best way to determine whether a component is faulty is to swap it out. For example, if you think your graphics card may be causing your computer to blue screen, pull the graphics card out of your computer and swap in a new graphics card. If everything is working well, it’s likely that your previous graphics card was bad. This isn’t easy for people who don’t have boxes of components sitting around, but it’s the ideal way to troubleshoot. Troubleshooting is all about trial and error, and swapping components out allows you to pin down which component is actually causing the problem through a process of elimination. This isn’t a complete guide to everything that could likely go wrong and how to identify it — someone could write a full textbook on identifying failing components and still not cover everything. But the tips above should give you some places to start dealing with the more common problems. Image Credit: Justin Marty on Flickr     

    Read the article

  • Updating a database connection password using a script

    - by Tim Dexter
    An interesting customer requirement that I thought was worthy of sharing today. Thanks to James for the requirement and Bryan for the proposed solution and me for testing the solution and proving it works :0) A customers implementation of Sarbanes Oxley requires them to change all database account passwords every 90 days. This is scripted leveraging shell scripts today for most of their environments. But how can they manage the BI Publisher connections? Now, the customer is running 11g and therefore using weblogic on the middle tier, which is the first clue to Bryans proposed solution. To paraphrase and embellish Bryan's solution a little; why not use a JNDI connection from BIP to the database. Then employ the web logic scripting engine to make updates to the JNDI as needed? BIP is completely uninvolved and with a little 'timing' users will be completely unaware of the password updates i.e. change the password when reports are not being executed. Perfect! James immediately tracked down the WLST script that could be used here, http://middlewaremagic.com/weblogic/?p=4261 (thanks Ravish) Now it was just a case of testing the theory. Some steps: Create the JNDI connection in WLS Create the JNDI connection in BI Publisher pointing to the WLS connection Build new data models using or re-point data sources to use the JNDI connection. Create the WLST script to update the WLS JNDI password as needed. Test! Some details. Creating the JNDI connection in web logic is pretty straightforward. Log into hte console and look for Data Sources under the Services section of the home page and click it Click New >> Generic Datasource Give the connection a name. For the JNDI name, prefix it with 'jdbc/' so I have 'jdbc/localdb' - this name is important you'll need it on the BIP side. Select your db type - this will influence the drivers and information needed on the next page. Being a company man, Im using an Oracle db. Click Next Select the driver of choice, theres lots I know, you can read about them I just chose 'Oracle's Driver (Thin) for Instance connections; Versions 9.0.1 and later' Click Next >> Next Fill out the db name (SID), server, port, username to connect and password >> Next Test the config to ensure you can connect. >> Next Now you need to deploy the connection to your BI server, select it and click Next. You're done with the JNDI config. Creating the JNDI connection on the Publisher side is covered here. Just remember to the connection name you created in WLS e.g. 'jdbc/localdb' Not gonna tell you how to do this, go read the user guide :0) Suffice to say, it works. This requires a little reading around the subject to understand the scripting engine and how to execute scripts. Nicely covered here. However a bit of googlin' and I found an even easier way of running the script. ${ServerHome}/common/bin/wlst.sh updatepwd.py Where updatepwd.py is my script file, it can be in another directory. As part of the wlst.sh script your environment is set up for you so its very simple to execute. The nitty gritty: Need to take Ravish's script above and create a file with a .py extension. Its going to need some modification, as he explains on the web page, to make it work in your environment. I played around with it for a while but kept running into errors. The script as is, tries to loop through all of your connections and modify the user and passwords for each. Not quite what we are looking for. Remember our requirement is to just update the password for a given connection. I also found another issue with the script. WLS 10.x does not allow updates to passwords using clear type ie un-encrypted text while the server is in production mode. Its a bit much to set it back to developer mode bounce it, change the passwords and then bounce and then change back to production and bounce again. After lots of messing about I finally came up with the following: ############################################################################# # # Update password for JNDI connections # ############################################################################# print("*** Trying to Connect.... *****") connect('weblogic','welcome1','t3://localhost:7001') print("*** Connected *****") edit() startEdit() print ("*** Encrypt the password ***") en = encrypt('hr') print "Encrypted pwd: ", en print ("*** Changing pwd for LocalDB ***") dsName = 'LocalDB' print 'Changing Password for DataSource ', dsName cd('/JDBCSystemResources/'+dsName+'/JDBCResource/'+dsName+'/JDBCDriverParams/'+dsName) set('PasswordEncrypted',en) save() activate() Its pretty simple and you can expand on it to loop through the data sources and change each as needed. I have hardcoded the password into the file but you can pass it as a parameter as needed using the properties file method. Im not going to get into the detail of that here but its covered with an example here. Couple of points to note: 1. The change to the password requires a server bounce to get the changes picked up. You can add that to the shell script you will use to call the script above. 2. The script above needs to be run from the MW_HOME\user_projects\domains\bifoundation_domain directory to get the encryption libraries set correctly. My command to run the whole script was: d:\oracle\bi_mw\wlserver_10.3\common\bin\wlst.cmd updatepwd.py - where wlst.cmd is the scripting command line and updatepwd.py was my update password script above. I have not quite spoon fed everything you need to make it a robust script but at least you know you can do it and you can work out the rest I think :0)

    Read the article

  • Source-control 'wet-work'?

    - by Phil Factor
    When a design or creative work is flawed beyond remedy, it is often best to destroy it and start again. The other day, I lost the code to a long and intricate SQL batch I was working on. I’d thought it was impossible, but it happened. With all the technology around that is designed to prevent this occurring, this sort of accident has become a rare event.  If it weren’t for a deranged laptop, and my distraction, the code wouldn’t have been lost this time.  As always, I sighed, had a soothing cup of tea, and typed it all in again.  The new code I hastily tapped in  was much better: I’d held in my head the essence of how the code should work rather than the details: I now knew for certain  the start point, the end, and how it should be achieved. Instantly the detritus of half-baked thoughts fell away and I was able to write logical code that performed better.  Because I could work so quickly, I was able to hold the details of all the columns and variables in my head, and the dynamics of the flow of data. It was, in fact, easier and quicker to start from scratch rather than tidy up and refactor the existing code with its inevitable fumbling and half-baked ideas. What a shame that technology is now so good that developers rarely experience the cleansing shock of losing one’s code and having to rewrite it from scratch.  If you’ve never accidentally lost  your code, then it is worth doing it deliberately once for the experience. Creative people have, until Technology mistakenly prevented it, torn up their drafts or sketches, threw them in the bin, and started again from scratch.  Leonardo’s obsessive reworking of the Mona Lisa was renowned because it was so unusual:  Most artists have been utterly ruthless in destroying work that didn’t quite make it. Authors are particularly keen on writing afresh, and the results are generally positive. Lawrence of Arabia actually lost the entire 250,000 word manuscript of ‘The Seven Pillars of Wisdom’ by accidentally leaving it on a train at Reading station, before rewriting a much better version.  Now, any writer or artist is seduced by technology into altering or refining their work rather than casting it dramatically in the bin or setting a light to it on a bonfire, and rewriting it from the blank page.  It is easy to pick away at a flawed work, but the real creative process is far more brutal. Once, many years ago whilst running a software house that supplied commercial software to local businesses, I’d been supervising an accounting system for a farming cooperative. No packaged system met their needs, and it was all hand-cut code.  For us, it represented a breakthrough as it was for a government organisation, and success would guarantee more contracts. As you’ve probably guessed, the code got mangled in a disk crash just a week before the deadline for delivery, and the many backups all proved to be entirely corrupted by a faulty tape drive.  There were some fragments left on individual machines, but they were all of different versions.  The developers were in despair.  Strangely, I managed to re-write the bulk of a three-month project in a manic and caffeine-soaked weekend.  Sure, that elegant universally-applicable input-form routine was‘nt quite so elegant, but it didn’t really need to be as we knew what forms it needed to support.  Yes, the code lacked architectural elegance and reusability. By dawn on Monday, the application passed its integration tests. The developers rose to the occasion after I’d collapsed, and tidied up what I’d done, though they were reproachful that some of the style and elegance had gone out of the application. By the delivery date, we were able to install it. It was a smaller, faster application than the beta they’d seen and the user-interface had a new, rather Spartan, appearance that we swore was done to conform to the latest in user-interface guidelines. (we switched to Helvetica font to look more ‘Bauhaus’ ). The client was so delighted that he forgave the new bugs that had crept in. I still have the disk that crashed, up in the attic. In IT, we have had mixed experiences from complete re-writes. Lotus 123 never really recovered from a complete rewrite from assembler into C, Borland made the mistake with Arago and Quattro Pro  and Netscape’s complete rewrite of their Navigator 4 browser was a white-knuckle ride. In all cases, the decision to rewrite was a result of extreme circumstances where no other course of action seemed possible.   The rewrite didn’t come out of the blue. I prefer to remember the rewrite of Minix by young Linus Torvalds, or the rewrite of Bitkeeper by a slightly older Linus.  The rewrite of CP/M didn’t do too badly either, did it? Come to think of it, the guy who decided to rewrite the windowing system of the Xerox Star never regretted the decision. I’ll agree that one should often resist calls for a rewrite. One of the worst habits of the more inexperienced programmer is to denigrate whatever code he or she inherits, and then call loudly for a complete rewrite. They are buoyed up by the mistaken belief that they can do better. This, however, is a different psychological phenomenon, more related to the idea of some motorcyclists that they are operating on infinite lives, or the occasional squaddies that if they charge the machine-guns determinedly enough all will be well. Grim experience brings out the humility in any experienced programmer.  I’m referring to quite different circumstances here. Where a team knows the requirements perfectly, are of one mind on methodology and coding standards, and they already have a solution, then what is wrong with considering  a complete rewrite? Rewrites are so painful in the early stages, until that point where one realises the payoff, that even I quail at the thought. One needs a natural disaster to push one over the edge. The trouble is that source-control systems, and disaster recovery systems, are just too good nowadays.   If I were to lose this draft of this very blog post, I know I’d rewrite it much better. However, if you read this, you’ll know I didn’t have the nerve to delete it and start again.  There was a time that one prayed that unreliable hardware would deliver you from an unmaintainable mess of a codebase, but now technology has made us almost entirely immune to such a merciful act of God. An old friend of mine with long experience in the software industry has long had the idea of the ‘source-control wet-work’,  where one hires a malicious hacker in some wild eastern country to hack into one’s own  source control system to destroy all trace of the source to an application. Alas, backup systems are just too good to make this any more than a pipedream. Somehow, it would be difficult to promote the idea. As an alternative, could one construct a source control system that, on doing all the code-quality metrics, would systematically destroy all trace of source code that failed the quality test? Alas, I can’t see many managers buying into the idea. In reading the full story of the near-loss of Toy Story 2, it set me thinking. It turned out that the lucky restoration of the code wasn’t the happy ending one first imagined it to be, because they eventually came to the conclusion that the plot was fundamentally flawed and it all had to be rewritten anyway.  Was this an early  case of the ‘source-control wet-job’?’ It is very hard nowadays to do a rapid U-turn in a development project because we are far too prone to cling to our existing source-code.

    Read the article

  • Siemens AG, Sector Healthcare, Increases Transparency and Improves Customer Loyalty with Web Portal Solution

    - by Kellsey Ruppel
    Siemens AG, Sector Healthcare, Increases Transparency and Improves Customer Loyalty with Web Portal Solution CUSTOMER AND PARTNER INFORMATION Customer Name – Siemens AG, Sector Healthcare Customer Revenue – 73,515 Billion Euro (2011, Siemens AG total) Customer Quote – “The realization of our complex requirements within a very short amount of time was enabled through the competent implementation partner Sapient, who fully used the  very broad scope of standard functionality provided in the Oracle WebCenter Portal, and the management of customer services, who continuously supported the project setup. ” – Joerg Modlmayr, Project Manager, Healthcare Customer Service Portal, Siemens AG The Siemens Healthcare Sector is one of the world's largest suppliers to the healthcare industry and a trendsetter in medical imaging, laboratory diagnostics, medical information technology and hearing aids. Siemens offers its customers products and solutions for the entire range of patient care from a single source – from prevention and early detection to diagnosis, and on to treatment and aftercare. By optimizing clinical workflows for the most common diseases, Siemens also makes healthcare faster, better and more cost-effective. To ensure greater transparency, increased efficiency, higher user acceptance, and additional services, Siemens AG, Sector Healthcare, replaced several existing legacy portal solutions that could not meet the company’s future needs with Oracle WebCenter Portal. Various existing portal solutions that cannot meet future demands will be successively replaced by the new central service portal, which will also allow for the efficient and intuitive implementation of new service concepts.  With Oracle, doctors and hospitals using Siemens medical solutions now have access to a central information portal that provides important information and services at just the push of a button.  Customer Name – Siemens AG, Sector Healthcare Customer URL – www.siemens.com Customer Headquarters – Erlangen, Germany Industry – Industrial Manufacturing Employees – 360,000  Challenges – Replace disparate medical service portals to meet future demands and eliminate an  unnecessarily high level of administrative work caused by heterogeneous installations Ensure portals meet current user demands to improve user-acceptance rates and increase number of total users Enable changes and expansion through standard functionality to eliminate the need for reliance on IT and reduce administrative efforts and associated high costs Ensure efficient and intuitive implementation of new service concepts for all devices and systems Ensure hospitals and clinics to transparently monitor and measure services rendered for the various medical devices and systems  Increase electronic interaction and expand services to achieve a higher level of customer loyalty Solution –  Deployed Oracle WebCenter Portal to ensure greater transparency, and as a result, a higher level of customer loyalty  Provided a centralized platform for doctors and hospitals using Siemens’ medical technology solutions that provides important information and services at the push of a button Reduced significantly the administrative workload by centralizing the solution in the new customer service portal Secured positive feedback from customers involved in the pilot program developed by design experts from Oracle partner Sapient. The interfaces were created with customer needs in mind. The first survey taken shortly after implementation came back with 2.4 points on a scale of 0-3 in the category “customer service portal intuitiveness level” Met all requirements including alignment with the Siemens Style Guide without extensive programming Implemented additional services via the portal such as benchmarking options to ensure the optimal use of the Customer Device Park Provided option for documentation of all services rendered in conjunction with the medical technology systems to ensure that the value of the services are transparent for the decision makers in the hospitals  Saved and stored all machine data from approximately 100,000 remote systems in the central service and information platform Provided the option to register errors online and follow the call status in real-time on the portal Made  available at the push of a button all information on the medical technology devices used in hospitals or clinics—from security checks and maintenance activities to current device statuses Provided PDF format Service Performance Reports that summarize information from periods of time ranging from previous weeks up to one year, meeting medical product law requirements  Why Oracle – Siemens AG favored Oracle for many reasons, however, the company ultimately decided to go with Oracle due to the enormous range of functionality the solutions offered for the healthcare sector.“We are not programmers; we are service providers in the medical technology segment and focus on the contents of the portal. All the functionality necessary for internet-based customer interaction is already standard in Oracle WebCenter Portal, which is a huge plus for us. Having Oracle as our technology partner ensures that the product will continually evolve, providing a strong technology platform for our customer service portal well into the future,” said Joerg Modlmayr project manager, Healthcare Customer Service Portal, Siemens AG. Partner Involvement – Siemens AG selected Oracle Partner Sapient because the company offered a service portfolio that perfectly met Siemens’ requirements and had a wealth of experience implementing Oracle WebCenter Portal. Additionally, Sapient had designers with a very high level of expertise in usability—an aspect that Siemens considered to be of vast importance for the project.  “The Sapient team completely met all our expectations. Our tightly timed project was completed on schedule, and the positive feedback from our users proves that we set the right measures in terms of usability—all thanks to the folks at Sapient,” Modlmayr said.  Partner Name – Sapient GmbH Deutschland Partner URL – www.sapient.com

    Read the article

  • SQL SERVER – ?Finding Out What Changed in a Deleted Database – Notes from the Field #041

    - by Pinal Dave
    [Note from Pinal]: This is a 41th episode of Notes from the Field series. The real world is full of challenges. When we are reading theory or book, we sometimes do not realize how real world reacts works and that is why we have the series notes from the field, which is extremely popular with developers and DBA. Let us talk about interesting problem of how to figure out what has changed in the DELETED database. Well, you think I am just throwing the words but in reality this kind of problems are making our DBA’s life interesting and in this blog post we have amazing story from Brian Kelley about the same subject. In this episode of the Notes from the Field series database expert Brian Kelley explains a how to find out what has changed in deleted database. Read the experience of Brian in his own words. Sometimes, one of the hardest questions to answer is, “What changed?” A similar question is, “Did anything change other than what we expected to change?” The First Place to Check – Schema Changes History Report: Pinal has recently written on the Schema Changes History report and its requirement for the Default Trace to be enabled. This is always the first place I look when I am trying to answer these questions. There are a couple of obvious limitations with the Schema Changes History report. First, while it reports what changed, when it changed, and who changed it, other than the base DDL operation (CREATE, ALTER, DELETE), it does not present what the changes actually were. This is not something covered by the default trace. Second, the default trace has a fixed size. When it hits that size, the changes begin to overwrite. As a result, if you wait too long, especially on a busy database server, you may find your changes rolled off. But the Database Has Been Deleted! Pinal cited another issue, and that’s the inability to run the Schema Changes History report if the database has been dropped. Thankfully, all is not lost. One thing to remember is that the Schema Changes History report is ultimately driven by the Default Trace. As you may have guess, it’s a trace, like any other database trace. And the Default Trace does write to disk. The trace files are written to the defined LOG directory for that SQL Server instance and have a prefix of log_: Therefore, you can read the trace files like any other. Tip: Copy the files to a working directory. Otherwise, you may occasionally receive a file in use error. With the Default Trace files, if you ask the question early enough, you can see the information for a deleted database just the same as any other database. Testing with a Deleted Database: Here’s a short script that will create a database, create a schema, create an object, and then drop the database. Without the database, you can’t do a standard Schema Changes History report. CREATE DATABASE DeleteMe; GO USE DeleteMe; GO CREATE SCHEMA Test AUTHORIZATION dbo; GO CREATE TABLE Test.Foo (FooID INT); GO USE MASTER; GO DROP DATABASE DeleteMe; GO This sets up the perfect situation where we can’t retrieve the information using the Schema Changes History report but where it’s still available. Finding the Information: I’ve sorted the columns so I can see the Event Subclass, the Start Time, the Database Name, the Object Name, and the Object Type at the front, but otherwise, I’m just looking at the trace files using SQL Profiler. As you can see, the information is definitely there: Therefore, even in the case of a dropped/deleted database, you can still determine who did what and when. You can even determine who dropped the database (loginame is captured). The key is to get the default trace files in a timely manner in order to extract the information. If you want to get started with performance tuning and database security with the help of experts, read more over at Fix Your SQL Server. Reference: Pinal Dave (http://blog.sqlauthority.com)Filed under: Notes from the Field, PostADay, SQL, SQL Authority, SQL Query, SQL Security, SQL Server, SQL Tips and Tricks, T SQL

    Read the article

  • Developing Schema Compare for Oracle (Part 5): Query Snapshots

    - by Simon Cooper
    If you've emailed us about a bug you've encountered with the EAP or beta versions of Schema Compare for Oracle, we probably asked you to send us a query snapshot of your databases. Here, I explain what a query snapshot is, and how it helps us fix your bug. Problem 1: Debugging users' bug reports When we started the Schema Compare project, we knew we were going to get problems with users' databases - configurations we hadn't considered, features that weren't installed, unicode issues, wierd dependencies... With SQL Compare, users are generally happy to send us a database backup that we can restore using a single RESTORE DATABASE command on our test servers and immediately reproduce the problem. Oracle, on the other hand, would be a lot more tricky. As Oracle generally has a 1-to-1 mapping between instances and databases, any databases users sent would have to be restored to their own instance. Furthermore, the number of steps required to get a properly working database, and the size of most oracle databases, made it infeasible to ask every customer who came across a bug during our beta program to send us their databases. We also knew that there would be lots of issues with data security that would make it hard to get backups. So we needed an easier way to be able to debug customers issues and sort out what strange schema data Oracle was returning. Problem 2: Test execution time Another issue we knew we would have to solve was the execution time of the tests we would produce for the Schema Compare engine. Our initial prototype showed that querying the data dictionary for schema information was going to be slow (at least 15 seconds per database), and this is generally proportional to the size of the database. If you're running thousands of tests on the same databases, each one registering separate schemas, not only would the tests would take hours and hours to run, but the test servers would be hammered senseless. The solution To solve these, we needed to be able to populate the schema of a database without actually connecting to it. Well, the IDataReader interface is the primary way we read data from an Oracle server. The data dictionary queries we use return their data in terms of simple strings and numbers, which we then process and reconstruct into an object model, and the results of these queries are identical for identical schemas. So, we can record the raw results of the queries once, and then replay these results to construct the same object model as many times as required without needing to actually connect to the original database. This is what query snapshots do. They are binary files containing the raw unprocessed data we get back from the oracle server for all the queries we run on the data dictionary to get schema information. The core of the query snapshot generation takes the results of the IDataReader we get from running queries on Oracle, and passes the row data to a BinaryWriter that writes it straight to a file. The query snapshot can then be replayed to create the same object model; when the results of a specific query is needed by the population code, we can simply read the binary data stored in the file on disk and present it through an IDataReader wrapper. This is far faster than querying the server over the network, and allows us to run tests in a reasonable time. They also allow us to easily debug a customers problem; using a simple snapshot generation program, users can generate a query snapshot that could be sent along with a bug report that we can immediately replay on our machines to let us debug the issue, rather than having to obtain database backups and restore databases to test systems. There are also far fewer problems with data security; query snapshots only contain schema information, which is generally less sensitive than table data. Query snapshots implementation However, actually implementing such a feature did have a couple of 'gotchas' to it. My second blog post detailed the development of the dependencies algorithm we use to ensure we get all the dependencies in the database, and that algorithm uses data from both databases to find all the needed objects - what database you're comparing to affects what objects get populated from both databases. We get information on these additional objects using an appropriate WHERE clause on all the population queries. So, in order to accurately replay the results of querying the live database, the query snapshot needs to be a snapshot of a comparison of two databases, not just populating a single database. Furthermore, although the code population queries (eg querying all_tab_cols to get column information) can simply be passed straight from the IDataReader to the BinaryWriter, we need to hook into and run the live dependencies algorithm while we're creating the snapshot to ensure we get the same WHERE clauses, and the same query results, as if we were populating straight from a live system. We also need to store the results of the dependencies queries themselves, as the resulting dependency graph is stored within the OracleDatabase object that is produced, and is later used to help order actions in synchronization scripts. This is significantly helped by the dependencies algorithm being a deterministic algorithm - given the same input, it will always return the same output. Therefore, when we're replaying a query snapshot, and processing dependency information, we simply have to return the results of the queries in the order we got them from the live database, rather than trying to calculate the contents of all_dependencies on the fly. Query snapshots are a significant feature in Schema Compare that really helps us to debug problems with the tool, as well as making our testers happier. Although not really user-visible, they are very useful to the development team to help us fix bugs in the product much faster than we otherwise would be able to.

    Read the article

  • 24 Hours of PASS – first reflections

    - by Rob Farley
    A few days after the end of 24HOP, I find myself reflecting on it. I’m still waiting on most of the information. I want to be able to discover things like where the countries represented on each of the sessions, and things like that. So far, I have the feedback scores and the numbers of attendees. The data was provided in a PDF, so while I wait for it to appear in a more flexible format, I’ve pushed the 24 attendee numbers into Excel. This chart shows the numbers by time. Remember that we started at midnight GMT, which was 10:30am in my part of the world and 8pm in New York. It’s probably no surprise that numbers drooped a bit at the start, stayed comparatively low, and then grew as the larger populations of the English-speaking world woke up. I remember last time 24HOP ran for 24 hours straight, there were quite a few sessions with less than 100 attendees. None this time though. We got close, but even when it was 4am in New York, 8am in London and 7pm in Sydney (which would have to be the worst slot for attracting people), we still had over 100 people tuning in. As expected numbers grew as the UK woke up, and even more so as the US did, with numbers peaking at 755 for the “3pm in New York” session on SQL Server Data Tools. Kendra Little almost reached those numbers too, and certainly contributed the biggest ‘spike’ on the chart with her session five hours earlier. Of all the sessions, Kendra had the highest proportion of ‘Excellent’s for the “Overall Evaluation of the session” question, and those of you who saw her probably won’t be surprised by that. Kendra had one of the best ranked sessions from the 24HOP event this time last year (narrowly missing out on being top 3), and she has produced a lot of good video content since then. The reports indicate that there were nearly 8.5 thousand attendees across the 24 sessions, averaging over 350 at each one. I’m looking forward to seeing how many different people that was, although I do know that Wil Sisney managed to attend every single one (if you did too, please let me know). Wil even moderated one of the sessions, which made his feat even greater. Thanks Wil. I also want to send massive thanks to Dave Dustin. Dave probably would have attended all of the sessions, if it weren’t for a power outage that forced him to take a break. He was also a moderator, and it was during this session that he earned special praise. Part way into the session he was moderating, the speaker lost connectivity and couldn’t get back for about fifteen minutes. That’s an incredibly long time when you’re in a live presentation. There were over 200 people tuned in at the time, and I’m sure Dave was as stressed as I was to have a speaker disappear. I started chasing down a phone number for the speaker, while Dave spoke to the audience. And he did brilliantly. He started answering questions, and kept doing that until the speaker came back. Bear in mind that Dave hadn’t expected to give a presentation on that topic (or any other), and was simply drawing on his SQL expertise to get him through. Also consider that this was between midnight at 1am in Dave’s part of the world (Auckland, NZ). I would’ve been expecting just to welcome people, monitor questions, probably read some out, and in general, help make things run smoothly. He went far beyond the call of duty, and if I had a medal to give him, he’d definitely be getting one. On the whole, I think this 24HOP was a success. We tried a different platform, and I think for the most part it was a popular move. We didn’t ask the question “Was this better than LiveMeeting?”, but we did get a number of people telling us that they thought the platform was very good. Some people have told me I get a chance to put my feet up now that this is over. As I’m also co-ordinating a tour of SQLSaturday events across the Australia/New Zealand region, I don’t quite get to take that much of a break (plus, there’s the little thing of squeezing in seven SQL 2012 exams over the next 2.5 weeks). But I am pleased to be reflecting on this event rather than anticipating it. There were a number of factors that could have gone badly, but on the whole I’m pleased about how it went. A massive thanks to everyone involved. If you’re reading this and thinking you wish you could’ve tuned in more, don’t worry – they were all recorded and you’ll be able to watch them on demand very soon. But as well as that, PASS has a stream of content produced by the Virtual Chapters, so you can keep learning from the comfort of your desk all year round. More info on them at sqlpass.org, of course.

    Read the article

  • Real Time BI in the Real World

    - by tobin.gilman(at)oracle.com
    Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman","serif";} Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman","serif"; mso-fareast-font-family:"Times New Roman";} One of my favorite BI offerings from Oracle is a solution called Oracle Real Time Decisions.  Whenever I mention this product in customer meetings, eyes light up.  There are some fascinating examples of customers using it to up-sell, cross-sell, increase customer retention, and reduce risk in real time, with off the charts return on investment. I plan to share some of those stories in a future blog.  In this post however, I want to share some far more common real time analytics use case scenarios that are being addressed with widely deployed Oracle BI and data integration technologies Not all real time BI applications require continuous learning, predictive modeling, and data mining.  Many simply require the ability to integrate, aggregate, and access information that is current (typically within in few minutes or a few seconds).  The use cases are infinite.  A few I've seen: ·         Purchasing agents need to match demand against available inventory ·         Manufacturing planners need to monitor current parts and material against scheduled build plans ·         Airline agents need to match ticket demand against flight schedules, ·         Human resources managers need to track the status of global hiring requisitions against current headcount authorizations...you get the idea. One way of doing this is to run reports or federated queries directly against transactional systems.  That approach can be viable if you only need to access simple data sets on rare occasions.  High volume and complex queries can quickly bog down performance of mission critical transactional systems.  There is an architecturally simple way of solving the problem, and it's being applied by real companies around the world to solve real needs in real time.    Cbeyond is an Atlanta, GA based  provider of voice, data and mobile business applications delivers.  They deliver real time information to its call center agents  as they are interacting with their customers. The data they need resides in production CRM and other transactional systems, but  instead or reporting directly off the those systems, data is first moved to an operational data store (ODS).  Rather than running data intensive, time consuming, and performance degrading batch ETL routines to populate the ODS, Cbeyond uses Oracle Golden Gate software to incrementally capture and move only the changed records from log files of the transactional systems every few minutes.  There is no impact on transactional system performance, and the information needed by call center representatives is up to date.  Oracle Business Intelligence software presents the information to services reps in a rich, visual, and highly interactive format. Avea is similar to Cbeyond.  They are a telecommunications company who integrates billing and customer information in an ODS that is accessed by their call center agents in real time using Oracle Golden Gate and Oracle Business Intelligence.  They've taken it a step further by using the ODS to feed a data warehouse.  The operational data store provides the current information needed by call center agents during "in flight" customer interactions.  The data warehouse is used for more sophisticated analysis of historical data.  For maximum performance, both the ODS and data warehouse run on the Oracle Exadata Database Machine. These are practical illustrations of companies addressing real time reporting and analysis needs using established business intelligence/data warehousing methodologies and tools common to many IT departments.  If real time BI could benefit your organization, you may be already be closer than you thought to having the pieces in place to solving the problem.    Give us a shout if you are interested in learning more or if you have an interesting use or approach to real-time BI.

    Read the article

  • Taking a Flying Leap

    - by Lance Shaw
    Yesterday, I went skydiving with three of my children.  It was thrilling, scary, invigorating and exciting. While there is obvious risk involved, the reward and feeling of success was well worth it. You might already be wondering what skydiving would have to with WebCenter, so let me explain. Implementing a skydiving program and becoming an instructor does not happen overnight.  It does not happen with the purchase of the needed technology. Not one of us would go out, buy a parachute, the harnesses, helmet and all the gear and be able to convince anyone that we are now ready to be a skydiving instructor. The fact is that obtaining the technology is merely a small piece of the overall process and so is the case with managing content in your company. You don't just buy the right software (Oracle WebCenter Content) and go to your boss and declare information management success. There is planning, research and effort that goes into deploying software of any kind and especially when it is as mission-critical to the success of your business as Enterprise Content Management. To become a certified skydiving instructor takes at least 3 years of commitment and often longer. In the United States, candidates must complete over 500 solo jumps of their own over a minimum of 36 months and then must complete additional rigorous training under observation.  When you consider the amount of time and effort involved, it's not unlike getting a college degree and anyone that has trusted their lives to one of these instructors will no doubt appreciate their dedication to the curriculum.  Implementing an ECM system won't take that long, but it certainly requires commitment, analysis and consideration. But guess what?  Humans are involved and that means that mistakes can happen and that rules change.  This struck me while reading an excellent post on darkreading.com by Glenn S. Phillips entitled "Mission Impossible: 4 Reasons Compliance is Impossible".  His over-arching point was that with information management and security, environments change and people are involved meaning the work is never done.  He stated that you can never claim your compliance efforts are complete because of the following reasons. People are involved.  And lets face it, some are more trustworthy than others. Change is Constant. There is always some new technology coming along that is disruptive. Consumer grade cloud file sharing and sync tools come to mind here. Compliance is interpreted, not defined.  Laws and the judges that read them are always on the move. Technology is a tool, not a complete solution. There is no magic pill. The skydiving analogy holds true here as well.  Ultimately, a single person packs your parachute.  For obvious reasons, you prefer that this person be trustworthy but there are no absolute guarantees of a 100% error-free scenario.  Weather and wind conditions are never a constant and the best-laid plans for a great day of skydiving are easily disrupted by forces outside of your control.  Rules and regulations vary by location and may be updated at any time and as I mentioned early on, even the best technology on its own will only get you started. The good news is that, like skydiving, with the right technology, the right planning, the right team and a proper understanding of the rules and regulations that govern your industry, your ECM deployment can be a great success.  Failure to plan for any of the 4 factors that Glenn outlined in his article will certainly put your deployment and maybe even your company at risk, so consider them carefully. As a final aside, for those of you who consider skydiving an incredibly dangerous and risky pastime, consider this comparative statistic.  In 2012, the U.S. Parachute Association recorded 19 fatal skydiving accidents in the U.S. out of roughly 3.1 million jumps.  That’s 0.006 fatalities per 1,000 jumps. By comparison, the U.S. National Highway Traffic Safety Administration reports that there were 34,080 deaths due to car accidents in 2012.  Based on the percentages, one could argue that it is safer to jump out of a plane than to drive to the airport where the skydiving will take place. While the way you manage, secure, classify, control, retain and dispose of company files may not carry as much risk as driving or skydiving, it certainly carries risk for the organization when not planned and deployed appropriately.  Consider all the factors involved in your organization as you make your content management plans.  For additional areas of consideration, be sure to download our free whitepaper on the topic entitled "The Top 10 Criteria for Choosing an ECM System" which is available for download here.

    Read the article

  • Part 8: How to name EBS Customizations

    - by volker.eckardt(at)oracle.com
    You might wonder why I am discussing this here. The reason is simple: nearly every project has a bit different naming conventions, which makes a the life always a bit complicated (for developers, but also setup responsible, and also for consultants).  Although we always create a document to describe the technical object naming conventions, I have rarely seen a dedicated document  with functional naming conventions. To be precisely, from my stand point, there should always be one global naming definition for an implementation! Let me discuss some related questions: What is the best convention for the customization reference? How to name database objects (tables, packages etc.)? How to name functional objects like Value Sets, Concurrent Programs, etc. How to separate customizations from standard objects best? What is the best convention for the customization reference? The customization reference is the key you use to reference your customization from other lists, from the project plan etc. Usually it is something like XXHU_CONV_22 (HU=customer abbreviation, CONV=Conversion object #22) or XXFA_DEPRN_RPT_02 (FA=Fixed Assets, DEPRN=Short object group, here depreciation, RPT=Report, 02=2nd report in this area) As this is just a reference (not an object name yet), I would prefer the second option. XX=Customization, FA=Main EBS Module linked (you may have sometimes more, but FA is the main) DEPRN_RPT=Short name to specify the customization 02=a unique number Important here is that the HU isn’t used, because XX is enough to mark a custom object, and the 3rd+4th char can be used by the EBS module short name. How to name database objects (tables, packages etc.)? I was leading different developer teams, and I know that one common way is it to take the Customization reference and add more chars behind to classify the object (like _V for view and _T1 for triggers etc.). The only concern I have with this approach is the reusability. If you name your view XXFA_DEPRN_RPT_02_V, no one will by choice reuse this nice view, as it seams to be specific for this CEMLI. My suggestion is rather to name the view XXFA_DEPRN_PERIODS_V and allow herewith reusability for other CEMLIs (although the view will be deployed primarily with CEMLI package XXFA_DEPRN_RPT_02). (check also one of the following Blogs where I will talk about deployment.) How to name Value Sets, Concurrent Programs, etc. For Value Sets I would go with the same convention as for database objects, starting with XX<Module> …. For Concurrent Programs the situation is a bit different. This “object” is seen and used by a lot of users, and they will search for. In many projects it is common to start again with the company short name, or with XX. My proposal would differ. If you have created your own report and you name it “XX: Invoice Report”, the user has to remember that this report does not start with “I”, it starts with X. Would you like typing an X if you are looking for an Invoice report? No, you wouldn’t! So my advise would be to name it:   “Invoice Report (XXAP)”. Still we know it is custom (because of the XXAP), but the end user will type the key “i” to get it (and will see similar reports starting also with “i”). I hope that the general schema behind has now become obvious. How to separate customizations from standard objects best? I would not have this section here if the naming would not play an important role. Unfortunately, we can not always link a custom application to our own object, therefore the naming is really important. In the file system structure we use our $XXyy_TOP, in JAVA_TOP it is perhaps also “xx” in front. But in the database itself? Although there are different concepts in place, still many implementations are using the standard “apps” approach, means custom objects are stored in the apps schema (which should not cause any trouble). Final advise: review the naming conventions regularly, once a month. You may have to add more! And, publish them! To summarize: Technical and functional customized objects should always follow a naming convention. This naming convention should be project wide, and only one place shall be used to maintain (like in a Wiki). If the name is for the end user, rather put a customization identifier at the end; if it is an internal name, start with XX…

    Read the article

  • NDepend Evaluation: Part 3

    - by Anthony Trudeau
    NDepend is a Visual Studio add-in designed for intense code analysis with the goal of high code quality. NDepend uses a number of metrics and aggregates the data in pleasing static and active visual reports. My evaluation of NDepend will be broken up into several different parts. In the first part of the evaluation I looked at installing the add-in.  And in the last part I went over my first impressions including an overview of the features.  In this installment I provide a little more detail on a few of the features that I really like. Dependency Matrix The dependency matrix is one of the rich visual components provided with NDepend.  At a glance it lets you know where you have coupling problems including cycles.  It does this with number indicating the weight of the dependency and a color-coding that indicates the nature of the dependency. Green and blue cells are direct dependencies (with the difference being whether the relationship is from row-to-column or column-to-row).  Black cells are the ones that you really want to know about.  These indicate that you have a cycle.  That is, type A refers to type B and type B also refers to Type A. But, that’s not the end of the story.  A handy pop-up appears when you hover over the cell in question.  It explains the color, the dependency, and provides several interesting links that will teach you more than you want to know about the dependency. You can double-click the problem cells to explode the dependency.  That will show the dependencies on a method-by-method basis allowing you to more easily target and fix the problem.  When you’re done you can click the back button on the toolbar. Dependency Graph The dependency graph is another component provided.  It’s complementary to the dependency matrix, but it isn’t as easy to identify dependency issues using the window. On a positive note, it does provide more information than the matrix. My biggest issue with the dependency graph is determining what is shown.  This was not readily obvious.  I ended up using the navigation buttons to get an acceptable view.  I would have liked to choose what I see. Once you see the types you want you can get a decent idea of coupling strength based on the width of the dependency lines.  Double-arrowed lines are problematic and are shown in red.  The size of the boxes will be related to the metric being displayed.  This is controlled using the Box Size drop-down in the toolbar.  Personally, I don’t find the size of the box to be helpful, so I change it to Constant Font. One nice thing about the display is that you can see the entire path of dependencies when you hover over a type.  This is done by color-coding the dependencies and dependants.  It would be nice if selecting the box for the type would lock the highlighting in place. I did find a perhaps unintended work-around to the color-coding.  You can lock the color-coding in by hovering over the type, right-clicking, and then clicking on the canvas area to clear the pop-up menu.  You can then do whatever with it including saving it to an image file with the color-coding. CQL NDepend uses a code query language (CQL) to work with your code just like it was a database.  CQL cannot be confused with the robustness of T-SQL or even LINQ, but it represents an impressive attempt at providing an expressive way to enumerate and interrogate your code. There are two main windows you’ll use when working with CQL.  The CQL Query Explorer allows you to define what queries (rules) are run as part of a report – I immediately unselected rules that I don’t want in my results.  The CQL Query Edit window is where you can view or author your own rules.  The explorer window is pretty self-explanatory, so I won’t mention it further other than to say that any queries you author will appear in the custom group. Authoring your own queries is really hard to screw-up.  The Intellisense-like pop-ups tell you what you can do while making composition easy.  I was able to create a query within two minutes of playing with the editor.  My query warns if any types that are interfaces don’t start with an “I”. WARN IF Count > 0 IN SELECT TYPES WHERE IsInterface AND !NameLike “I” The results from the CQL Query Edit window are immediate. That fact makes it useful for ad hoc querying.  It’s worth mentioning two things that could make the experience smoother.  First, out of habit from using Visual Studio I expect to be able to scroll and press Tab to select an item in the list (like Intellisense).  You have to press Enter when you scroll to the item you want.  Second, the commands are case-sensitive.  I don’t see a really good reason to enforce that. CQL has a lot of potential not just in enforcing code quality, but also enforcing architectural constraints that your enterprise has defined. Up Next My next update will be the final part of the evaluation.  I will summarize my experience and provide my conclusions on the NDepend add-in. ** View Part 1 of the Evaluation ** ** View Part 2 of the Evaluation ** Disclaimer: Patrick Smacchia contacted me about reviewing NDepend. I received a free license in return for sharing my experiences and talking about the capabilities of the add-in on this site. There is no expectation of a positive review elicited from the author of NDepend.

    Read the article

  • BYOD-The Tablet Difference

    - by Samantha.Y. Ma
    By Allison Kutz, Lindsay Richardson, and Jennifer Rossbach, Sales Consultants Normal 0 false false false EN-US ZH-TW X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Calibri","sans-serif"; mso-bidi-font-family:"Times New Roman";} Less than three years ago, Apple introduced a new concept to the world: The Tablet. It’s hard to believe that in only 32 months, the iPad induced an entire new way to do business. Because of their mobility and ease-of-use, tablets have grown in popularity to keep up with the increasing “on the go” lifestyle, and their popularity isn’t expected to decrease any time soon. In fact, global tablet sales are expected to increase drastically within the next five years, from 56 million tablets to 375 million by 2016. Tablets have been utilized for every function imaginable in today’s world. With over 730,000 active applications available for the iPad, these tablets are educational devices, portable book collections, gateways into social media, entertainment for children when Mom and Dad need a minute on their own, and so much more. It’s no wonder that 74% of those who own a tablet use it daily, 60% use it several times a day, and an average of 13.9 hours per week are spent tapping away. Tablets have become a critical part of a user’s personal life; but why stop there? Businesses today are taking major strides in implementing these devices, with the hopes of benefiting from efficiency and productivity gains. Limo and taxi drivers use tablets as payment devices instead of traditional cash transactions. Retail outlets use tablets to find the exact merchandise customers are looking for. Professors use tablets to teach their classes, and business professionals demonstrate solutions and review reports from tablets. Since an overwhelming majority of tablet users have started to use their personal iPads, PlayBooks, Galaxys, etc. in the workforce, organizations have had to make a change. In many cases, companies are willing to make that change. In fact, 79% of companies are making new investments in mobility this year. Gartner reported that 90% of organizations are expected to support corporate applications on personal devices by 2014. It’s not just companies that are changing. Business professionals have become accustomed to tablets making their personal lives easier, and want that same effect in the workplace. Professionals no longer want to waste time manually entering data in their computer, or worse yet in a notebook, especially when the data has to be later transcribed to an online system. The response: the Bring Your Own Device phenomenon. According to Gartner, BOYD is “an alternative strategy allowing employees, business partners and other users to utilize a personally selected and purchased client device to execute enterprise applications and access data.” Employees whose companies embrace this trend are more efficient because they get to use devices they are already accustomed to. Tablets change the game when it comes to how sales professionals perform their jobs. Sales reps can easily store and access customer information and analytics using tablet applications, such as Oracle Fusion Tap. This method is much more enticing for sales reps than spending time logging interactions on their (what seem to be outdated) computers. Forrester & IDC reported that on average sales reps spend 65% of their time on activities other than selling, so having a tablet application to use on the go is extremely powerful. In February, Information Week released a list of “9 Powerful Business Uses for Tablet Computers,” ranging from “enhancing the customer experience” to “improving data accuracy” to “eco-friendly motivations”. Tablets compliment the lifestyle of professionals who strive to be effective and efficient, both in the office and on the road. Three Things Businesses Need to do to Embrace BYOD Make customer-facing websites tablet-friendly for consistent user experiences Develop tablet applications to continue to enhance the customer experience Embrace and use the technology that comes with tablets Almost 55 million people in the U.S. own tablets because they are convenient, easy, and powerful. These are qualities that companies strive to achieve with any piece of technology. The inherent power of the devices coupled with the growing number of business applications ensures that tablets will transform the way that companies and employees perform.

    Read the article

  • Soft lockup after upgrade - cannot install from live CD

    - by nbm
    I dual-boot MacIntel Core 2 duo. nVidia graphics. Ran upgrade from ubuntu 13.10 to 14.04 (64 bit). On restart ran into {numbers} Bug: soft lockup - CPU#0 stuck for 22s! [swapper/0:1] Tried loading earlier kernel: same problem Tried re-installing ubuntu from a liveCD that has worked in the past: version 13.04. Same problem. Tried re-partitioning hard drive using Mac OS X disk utility and then installing ubuntu 14.04LTS from liveCD. Same problem. Not possible to verify liveCD disk (creates same "soft lockup" bug.) Tried installing from the liveCD with version 13.04 that I know works (that's how I got Ubuntu on this machine in the first place.) Same problem. I know this is not a hardware problem as OS X works just fine, I am using it right now on the same machine. I have been using various versions of Ubuntu for 2 years. Things I cannot do: Open a terminal Verify CD image Start ubuntu from CD (same soft lockup problem) This problem is similar to some other questions, none of which have been satisfactorily answered: Ubuntu 14.04 soft lockup on Vostro 3500 Cannot do fresh install of Ubuntu 13.04 while booting from DVD: "soft lockup" bug Live CD stalls when installing Ubuntu 13.10 UPDATE 6/11/14: Following some much-appreciated advice from bain (see below) I burned a 12.04LTS disk and started with kernel parameters: noapic, no1apic, acpi=off, nomodeset, elevator=deadline, and clocksource=jiffies. With all of these parameters I was able to load the 12.04LTS CD ("Try without installing"). It worked fine. However, as soon as I tried to install Ubuntu from the CD, my wired ethernet (eth0) connection would hang. There are already various askubuntu questions and bug reports about this problem, none of which had answers for me. (E.g., dhclient eth0 does nothing, none of the various reset commands does anything, manually setting IP &etc does nothing. I could reliably kill the ethernet connection by clicking "install ubuntu" every single time.) I could go ahead and install 12.04 without an internet connection, but the install would freeze after mostly completing (I tried several times.) There were some relevant error messages in the details of the install output script that, IIRC, had to do with searching for missing files and not being able to access eth0 (internet) to get them. To be honest I gave up at that point and I'm not sure I wrote those down. If I find some notes I will post them. At this point I no longer have Ubuntu on my system. I wiped the partitions and am using exclusively OS X. I am leaving this question in case it helps anyone else with similar problems. I love open source and I love Linux, and the next machine I get I will probably just build from Arch. At the moment I miss repositories and a lot of other things about Ubuntu, but the OS X terminal is 'nix, I can pretty much use all the open source apps I like, and while I am not a fan of the Apple software it gets the job done for me. Unlike Ubuntu, which can't even install. I realize this isn't necessarily a place for a soapbox speech, but when I first installed 12.04 several years ago there were already people in the community complaining that Canonical was going too "commercial". But I loved it. Several years later and all I've seen is Canonical adding more not-so-useful bells and whistles to Ubuntu while continually failing to fix basic problems on upgrades. With a dual-boot (and sometimes triple-boot) system it always took me some tweaking to get an upgrade to work, and to some extent that is okay. But at this point I feel like Canonical ought to just put a price tag on Ubuntu. All I see is more commercialism and advertising and product tie-ins, and ongoing problems do not get fixed. I am a big fan of open-source, not-for profit enterprise. I am also a big fan of for-profit enterprise, which certainly has its place and usefulness. I am not a fan of companies who pretend to be in favor of open source but really are just out to make a buck, and IMNSHO that is what Canonical has become. This is a great community and I wish you all the best, but my next install of Linux will not be Ubuntu.

    Read the article

  • My own personal use of Oracle Linux

    - by wcoekaer
    It always is easier to explain something with examples... Many people still don't seem to understand some of the convenient things around using Oracle Linux and since I personally (surprise!) use it at home, let me give you an idea. I have quite a few servers at home and I also have 2 hosted servers with a hosted provider. The servers at home I use mostly to play with random Linux related things, or with Oracle VM or just try out various new Oracle products to learn more. I like the technology, it's like a hobby really. To be able to have a good installation experience and use an officially certified Linux distribution and not waste time trying to find the right libraries, I, of course, use Oracle Linux. Now, at least I can get a copy of Oracle Linux for free (even if I was not working for Oracle) and I can/could use that on as many servers at home (or at my company if I worked elsewhere) for testing, development and production. I just go to http://edelivery.oracle.com/linux and download the version(s) I want and off I go. Now, I also have the right (and not because I am an employee) to take those images and put them on my own server and give them to someone else, I in fact, just recently set up my own mirror on my own hosted server. I don't have to remove oracle-logos, I don't have to rebuild the ISO images, I don't have to recompile anything, I can just put the whole binary distribution on my own server without contract. Perfectly free to do so. Of course the source code of all of this is there, I have a copy of the UEK code at home, just cloned from https://oss.oracle.com/git/?p=linux-2.6-unbreakable.git. And as you can see, the entire changelog, checkins, merges from Linus's tree, complete overview of everything that got changed from kernel to kernel, from patch to patch, errata to errata. No obfuscating, no tar balls and spending time with diff, or go read bug reports to find out what changed (seems silly to me). Some of my servers are on the external network and I need to be current with security errata, but guess what, no problem, my servers are hooked up to http://public-yum.oracle.com which is open, free, and completely up to date, in a consistent, reliable way with any errata, security or bugfix. So I have nothing to worry about. Also, not because I am an employee. Anyone can. And, with this, I also can, and have, set up my own mirror site that hosts these RPMs. both binary and source rpms. Because I am free to get them and distribute them. I am quite capable of supporting my servers on my own, so I don't need to rely on the support organization so I don't need to have a support subscription :-). So I don't need to pay. Neither would you, at least not with Oracle Linux. Another cool thing. The hosted servers came (unfortunately) with Centos installed. While Centos works just fine as is, I tend to prefer to be current with my security errata(reliably) and I prefer to just maintain one yum repository instead of 2, I converted them over to Oracle Linux as well (in place) so they happily receive and use the exact same RPMs. Since Oracle Linux is exactly the same from a user/application point of view as RHEL, including files like /etc/redhat-release and no changes from .el. to .centos. I know I have nothing to worry about installing one of the RHEL applications. So, OL everywhere makes my life a lot easier and why not... Next! Since I run Oracle VM and I have -tons- of VM's on my machines, in some cases on my big WOPR box I have 15-20 VMs running. Well, no problem, OL is free and I don't have to worry about counting the number of VMs, whether it's 1, or 4, or more than 10 ... like some other alternatives started doing... and finally :) I like to try out new stuff, not 3 year old stuff. So with UEK2 as part of OL6 (and 6.3 in particular) I can play with a 3.0.x based kernel and it just installs and runs perfectly clean with OL6, so quite current stuff in an environment that I know works, no need to toy around with an unsupported pre-alpha upstream distribution with libraries and versions that are not compatible with production software (I have nothing against ubuntu or fedora or opensuse... just not what I can rely on or use for what I need, and I don't need a desktop). pretty compelling. I say... and again, it doesn't matter that I work for Oracle, if I was working elsewhere, or not at all, all of the above would still apply. Student, teacher, developer, whatever. contrast this with $349 for 2 sockets and oneguest and selfsupport per year to even just get the software bits.

    Read the article

  • Battery life starts at 2:30 hrs (99%), but less than 1 minute later is only 1:30 hrs (99%)

    - by zondu
    After searching this and other forums, I haven't seen this same issue listed anywhere for Ubuntu 12. Prior to installing Ubuntu 12.10, my Netbook (Acer AspireOne D250, SATA HDD) was consistently getting 2:30-3 hrs battery life under Windows XP Home, SP3. However, immediately after installing Ubuntu 12.10, the battery life starts out at 2:30 hrs (99%), but less than 1 minute later suddenly drops to 1:30 hrs (99%), which seems very odd. It could be a complete coincidence that the battery is suddenly flaky at the exact same moment that Ubuntu 12.10 was installed, but that doesn't seem likely. I'm a newbie to Ubuntu, so I don't have much experience tweaking/trouble-shooting yet. Here's what I've tried so far: enabled laptop mode (sudo su, then echo 5 /proc/sys/vm/laptop_mode) and checked that it is running when the A/C adapter is unplugged, but it doesn't seem to have made any noticeable difference in battery life, installed Jupiter, but it didn't work and messed up the system, so I had to uninstall it, disabled bluetooth (wifi is still on b/c it is necessary), set the screen to lowest brightness, etc., run through at least 1 full power cycle (running until the netbook shut itself off due to critical battery) and have been using it normally (sometimes plugged in, often unplugged until the battery gets very low) for a week since installing Ubuntu 12.10. installed powertop, but have no idea how to interpret its results. Here are the results of acpi -b: w/ A/C adapter: Battery 0: Full, 100% immediately after unplugging: Battery 0: Discharging, 99%, 02:30:20 remaining 1 minute after unplugging: Battery 0: Discharging, 99%, 01:37:49 remaining 2-3 minutes after unplugging: Battery 0: Discharging, 95%, 01:33:01 remaining 10 minutes after unplugging: Battery 0: Discharging, 85%, 01:13:38 remaining Results of cat /sys/class/power_supply/BAT0/uevent: w/ A/C adapter: POWER_SUPPLY_NAME=BAT0 POWER_SUPPLY_STATUS=Full POWER_SUPPLY_PRESENT=1 POWER_SUPPLY_TECHNOLOGY=Li-ion POWER_SUPPLY_CYCLE_COUNT=0 POWER_SUPPLY_VOLTAGE_MIN_DESIGN=10800000 POWER_SUPPLY_VOLTAGE_NOW=12136000 POWER_SUPPLY_CURRENT_NOW=773000 POWER_SUPPLY_CHARGE_FULL_DESIGN=4500000 POWER_SUPPLY_CHARGE_FULL=1956000 POWER_SUPPLY_CHARGE_NOW=1956000 POWER_SUPPLY_MODEL_NAME=UM08B32 POWER_SUPPLY_MANUFACTURER=SANYO POWER_SUPPLY_SERIAL_NUMBER= immediately after unplugging: POWER_SUPPLY_NAME=BAT0 POWER_SUPPLY_STATUS=Discharging POWER_SUPPLY_PRESENT=1 POWER_SUPPLY_TECHNOLOGY=Li-ion POWER_SUPPLY_CYCLE_COUNT=0 POWER_SUPPLY_VOLTAGE_MIN_DESIGN=10800000 POWER_SUPPLY_VOLTAGE_NOW=11886000 POWER_SUPPLY_CURRENT_NOW=773000 POWER_SUPPLY_CHARGE_FULL_DESIGN=4500000 POWER_SUPPLY_CHARGE_FULL=1956000 POWER_SUPPLY_CHARGE_NOW=1937000 POWER_SUPPLY_MODEL_NAME=UM08B32 POWER_SUPPLY_MANUFACTURER=SANYO POWER_SUPPLY_SERIAL_NUMBER= 1 minute later: POWER_SUPPLY_NAME=BAT0 POWER_SUPPLY_STATUS=Discharging POWER_SUPPLY_PRESENT=1 POWER_SUPPLY_TECHNOLOGY=Li-ion POWER_SUPPLY_CYCLE_COUNT=0 POWER_SUPPLY_VOLTAGE_MIN_DESIGN=10800000 POWER_SUPPLY_VOLTAGE_NOW=11728000 POWER_SUPPLY_CURRENT_NOW=1174000 POWER_SUPPLY_CHARGE_FULL_DESIGN=4500000 POWER_SUPPLY_CHARGE_FULL=1956000 POWER_SUPPLY_CHARGE_NOW=1937000 POWER_SUPPLY_MODEL_NAME=UM08B32 POWER_SUPPLY_MANUFACTURER=SANYO POWER_SUPPLY_SERIAL_NUMBER= 2-3 minutes later: POWER_SUPPLY_NAME=BAT0 POWER_SUPPLY_STATUS=Discharging POWER_SUPPLY_PRESENT=1 POWER_SUPPLY_TECHNOLOGY=Li-ion POWER_SUPPLY_CYCLE_COUNT=0 POWER_SUPPLY_VOLTAGE_MIN_DESIGN=10800000 POWER_SUPPLY_VOLTAGE_NOW=11583000 POWER_SUPPLY_CURRENT_NOW=1209000 POWER_SUPPLY_CHARGE_FULL_DESIGN=4500000 POWER_SUPPLY_CHARGE_FULL=1956000 POWER_SUPPLY_CHARGE_NOW=1878000 POWER_SUPPLY_MODEL_NAME=UM08B32 POWER_SUPPLY_MANUFACTURER=SANYO POWER_SUPPLY_SERIAL_NUMBER= 10 minutes later: POWER_SUPPLY_NAME=BAT0 POWER_SUPPLY_STATUS=Discharging POWER_SUPPLY_PRESENT=1 POWER_SUPPLY_TECHNOLOGY=Li-ion POWER_SUPPLY_CYCLE_COUNT=0 POWER_SUPPLY_VOLTAGE_MIN_DESIGN=10800000 POWER_SUPPLY_VOLTAGE_NOW=11230000 POWER_SUPPLY_CURRENT_NOW=1239000 POWER_SUPPLY_CHARGE_FULL_DESIGN=4500000 POWER_SUPPLY_CHARGE_FULL=1956000 POWER_SUPPLY_CHARGE_NOW=1644000 POWER_SUPPLY_MODEL_NAME=UM08B32 POWER_SUPPLY_MANUFACTURER=SANYO POWER_SUPPLY_SERIAL_NUMBER= Results of upower -i /org/freedesktop/UPower/devices/battery_BAT0: w/ A/C adapter: native-path: /sys/devices/LNXSYSTM:00/device:00/PNP0A08:00/device:02/PNP0C0A:00/power_supply/BAT0 vendor: SANYO model: UM08B32 power supply: yes updated: Tue Nov 27 15:24:58 2012 (823 seconds ago) has history: yes has statistics: yes battery present: yes rechargeable: yes state: fully-charged energy: 21.1248 Wh energy-empty: 0 Wh energy-full: 21.1248 Wh energy-full-design: 48.6 Wh energy-rate: 8.3484 W voltage: 12.173 V percentage: 100% capacity: 43.4667% technology: lithium-ion immediately after unplugging: native-path: /sys/devices/LNXSYSTM:00/device:00/PNP0A08:00/device:02/PNP0C0A:00/power_supply/BAT0 vendor: SANYO model: UM08B32 power supply: yes updated: Tue Nov 27 15:41:25 2012 (1 seconds ago) has history: yes has statistics: yes battery present: yes rechargeable: yes state: discharging energy: 20.9196 Wh energy-empty: 0 Wh energy-full: 21.1248 Wh energy-full-design: 48.6 Wh energy-rate: 8.3484 W voltage: 11.86 V time to empty: 2.5 hours percentage: 99.0286% capacity: 43.4667% technology: lithium-ion History (charge): 1354023683 99.029 discharging 1 minute later: native-path: /sys/devices/LNXSYSTM:00/device:00/PNP0A08:00/device:02/PNP0C0A:00/power_supply/BAT0 vendor: SANYO model: UM08B32 power supply: yes updated: Tue Nov 27 15:42:31 2012 (17 seconds ago) has history: yes has statistics: yes battery present: yes rechargeable: yes state: discharging energy: 20.9196 Wh energy-empty: 0 Wh energy-full: 21.1248 Wh energy-full-design: 48.6 Wh energy-rate: 13.5432 W voltage: 11.753 V time to empty: 1.5 hours percentage: 99.0286% capacity: 43.4667% technology: lithium-ion History (charge): 1354023683 99.029 discharging History (rate): 1354023751 13.543 discharging 2-3 minutes later: native-path: /sys/devices/LNXSYSTM:00/device:00/PNP0A08:00/device:02/PNP0C0A:00/power_supply/BAT0 vendor: SANYO model: UM08B32 power supply: yes updated: Tue Nov 27 15:45:06 2012 (20 seconds ago) has history: yes has statistics: yes battery present: yes rechargeable: yes state: discharging energy: 20.2824 Wh energy-empty: 0 Wh energy-full: 21.1248 Wh energy-full-design: 48.6 Wh energy-rate: 13.7484 W voltage: 11.545 V time to empty: 1.5 hours percentage: 96.0123% capacity: 43.4667% technology: lithium-ion History (charge): 1354023906 96.012 discharging 1354023844 97.035 discharging History (rate): 1354023906 13.748 discharging 1354023875 12.992 discharging 1354023844 13.284 discharging 10 minutes later: native-path: /sys/devices/LNXSYSTM:00/device:00/PNP0A08:00/device:02/PNP0C0A:00/power_supply/BAT0 vendor: SANYO model: UM08B32 power supply: yes updated: Tue Nov 27 15:54:24 2012 (28 seconds ago) has history: yes has statistics: yes battery present: yes rechargeable: yes state: discharging energy: 18.1764 Wh energy-empty: 0 Wh energy-full: 21.1248 Wh energy-full-design: 48.6 Wh energy-rate: 13.2948 W voltage: 11.268 V time to empty: 1.4 hours percentage: 86.0429% capacity: 43.4667% technology: lithium-ion History (charge): 1354024433 86.043 discharging History (rate): 1354024464 13.295 discharging 1354024433 13.662 discharging 1354024402 13.781 discharging I noticed that between #2 and #3 (0 and 1 minutes after unplugging), while the battery still reports 99% charge and drops from 2:30 hr to 1:30 hr, the energy usage goes from 8.34 W to 13.54 W and the current_now increases, but shouldn't it be using less energy in battery mode since the screen is much dimmer and it's in power saving mode? (or is that normal behavior?) It also seems to drain more quickly than what it predicts, especially with the 1-1.25 hour drop in the first minute of being unplugged, which seems odd. What really concerns me is that Ubuntu 12.10 may not be properly managing the battery (with the sudden change in charge/life from 2:30 to 1:30 or 1:15 within a minute of unplugging), and that a new battery may quickly die under Ubuntu 12.10. I'd greatly appreciate any advice/suggestions on what to do, and especially whether there's a way to get back the 1-1.5 hrs of battery life that were suddenly lost when changing from WinXp to Ubuntu 12.10. Thanks :)

    Read the article

  • IE9, LightSwitch Beta 2 and Zune HD: A Study in Risk Management?

    - by andrewbrust
    Photo by parl, 'Risk.’ Under Creative Commons Attribution-NonCommercial-NoDerivs License This has been a busy week for Microsoft, and for me as well.  On Monday, Microsoft launched Internet Explorer 9 at South by Southwest (SXSW) in Austin, TX.  That evening I flew from New York to Seattle.  On Tuesday morning, Microsoft launched Visual Studio LightSwitch, Beta 2 with a Go-Live license, in Redmond, and I had the privilege of speaking at the keynote presentation where the announcement was made.  Readers of this blog know I‘m a fan of LightSwitch, so I was happy to tell the app dev tools partners in the audience that I thought the LightSwitch extensions ecosystem represented a big opportunity – comparable to the opportunity when Visual Basic 1.0 was entering its final beta roughly 20 years ago.  On Tuesday evening, I flew back to New York (and wrote most of this post in-flight). Two busy, productive days.  But there was a caveat that impacts the accomplishments, because Monday was also the day reports surfaced from credible news agencies that Microsoft was discontinuing its dedicated Zune hardware efforts.  While the Zune brand, technology and service will continue to be a component of Windows Phone and a piece of the Xbox puzzle as well, speculation is that Microsoft will no longer be going toe-to-toe with iPod touch in the portable music player market. If we take all three of these developments together (even if one of them is based on speculation), two interesting conclusions can reasonably be drawn, one good and one less so. Microsoft is doubling down on technologies it finds strategic and de-emphasizing those that it does not.  HTML 5 and the Web are strategic, so here comes IE9, and it’s a very good browser.  Try it and see.  Silverlight is strategic too, as is SQL Server, Windows Azure and SQL Azure, so here comes Visual Studio LightSwitch Beta 2 and a license to deploy its apps to production.  Downloads of that product have exceeded Microsoft’s projections by more than 50%, and the company is even citing analyst firms’ figures covering the number of power-user developers that might use it. (I happen to think the product will be used by full-fledged developers as well, but that’s a separate discussion.) Windows Phone is strategic too…I wasn’t 100% positive of that before, but the Nokia agreement has made me confident.  Xbox as an entertainment appliance is also strategic.  Standalone music players are not strategic – and even if they were, selling them has been a losing battle for Microsoft.  So if Microsoft has consolidated the Zune content story and the ZunePass subscription into Xbox and Windows Phone, it would make sense, and would be a smart allocation of resources.  Essentially, it would be for the greater good. But it’s not all good.  In this scenario, Zune player customers would lose out.  Unless they wanted to switch to Windows Phone, and then use their phone’s battery for the portable media needs, they’re going to need a new platform.  They’re going to feel abandoned.  Even if Zune lives, there have been other such cul de sacs for customers.  Remember SPOT watches?  Live Spaces?  The original Live Mesh?  Microsoft discontinued each of these products.  The company is to be commended for cutting its losses, as admitting a loss isn’t easy.  But Redmond won’t be well-regarded by the victims of those decisions.  Instead, it gets black marks. What’s the answer?  I think it’s a bit like the 1980’s New York City “don’t block the box” gridlock rules: don’t enter an intersection unless you see a clear path through it.  If the light turns red and you’re blocking the perpendicular traffic, that’s your fault in judgment.  You get fined and get points on your license and you don’t get to shrug it off as beyond your control.  Accountability is key.  The same goes for Microsoft.  If it decides to enter a market, it should see a reasonable path through success in that market. Switching analogies, Microsoft shouldn’t make investments haphazardly, and it certainly shouldn’t ask investors to buy into a high-risk fund that is sold as safe and which offers only moderate returns.  People won’t continue to invest with a fund manager with a track record of over-zealous, imprudent, sub-prime investments.  The same is true on the product side for Microsoft, and not just with music players and geeky wrist watches.  It’s true of Web browsers, and line-of-business app dev tools, and smartphones, and cloud platforms and operating systems too.  When Microsoft is casual about its own risk, it raises risk for its customers, and weakens its reputation, market share and credibility.  That doesn’t mean all risk is bad, but it does mean no product team’s risk should be taken lightly. For mutual fund companies, it’s the CEO’s job to give his fund managers autonomy, but to make sure they’re conforming to a standard of rational risk management.  Because all those funds carry the same brand, and many of them serve the same investors. The same goes for Microsoft, its product portfolio, its executive ranks and its product managers.

    Read the article

  • What are some concise and comprehensive introductory guide to unit testing for a self-taught programmer [closed]

    - by Superbest
    I don't have much formal training in programming and I have learned most things by looking up solutions on the internet to practical problems I have. There are some areas which I think would be valuable to learn, but which ended up both being difficult to learn and easy to avoid learning for a self-taught programmer. Unit testing is one of them. Specifically, I am interested in tests in and for C#/.NET applications using Microsoft.VisualStudio.TestTools in Visual Studio 2010 and/or 2012, but I really want a good introduction to the principles so language and IDE shouldn't matter much. At this time I'm interested in relatively trivial tests for small or medium sized programs (development time of weeks or months and mostly just myself developing). I don't necessarily intend to do test-driven development (I am aware that some say unit testing alone is supposed to be for developing features in TDD, and not an assurance that there are no bugs in the software, but unit testing is often the only kind of testing for which I have resources). I have found this tutorial which I feel gave me a decent idea of what unit tests and TDD looks like, but in trying to apply these ideas to my own projects, I often get confused by questions I can't answer and don't know how to answer, such as: What parts of my application and what sorts of things aren't necessarily worth testing? How fine grained should my tests be? Should they test every method and property separately, or work with a larger scope? What is a good naming convention for test methods? (since apparently the name of the method is the only way I will be able to tell from a glance at the test results table what works in my program and what doesn't) Is it bad to have many asserts in one test method? Since apparently VS2012 reports only that "an Assert.IsTrue failed within method MyTestMethod", and if MyTestMethod has 10 Assert.IsTrue statements, it will be irritating to figure out why a test is failing. If a lot of the functionality deals with writing and reading data to/from the disk in a not-exactly trivial fashion, how do I test that? If I provide a bunch of files as input by placing them in the program's directory, do I have to copy those files to the test project's bin/Debug folder now? If my program works with a large body of data and execution takes minutes or more, should my tests have it do the whole use all of the real data, a subset of it, or simulated data? If latter, how do I decide on the subset or how to simulate? Closely related to the previous point, if a class is such that its main operation happens in a state that is arrived to by the program after some involved operations (say, a class makes calculations on data derived from a few thousands of lines of code analyzing some raw data) how do I test just that class without inevitably ending up testing that class and all the other code that brings it to that state along with it? In general, what kind of approach should I use for test initialization? (hopefully that is the correct term, I mean preparing classes for testing by filling them in with appropriate data) How do I deal with private members? Do I just suck it up and assume that "not public = shouldn't be tested"? I have seen people suggest using private accessors and reflection, but these feel like clumsy and unsuited for regular use. Are these even good ideas? Is there anything like design patterns concerning testing specifically? I guess the main themes in what I'd like to learn more about are, (1) what are the overarching principles that should be followed (or at least considered) in every testing effort and (2) what are popular rules of thumb for writing tests. For example, at one point I recall hearing from someone that if a method is longer than 200 lines, it should be refactored - not a universally correct rule, but it has been quite helpful since I'd otherwise happily put hundreds of lines in single methods and then wonder why my code is so hard to read. Similarly I've found ReSharpers suggestions on member naming style and other things to be quite helpful in keeping my codebases sane. I see many resources both online and in print that talk about testing in the context of large applications (years of work, 10s of people or more). However, because I've never worked on such large projects, this context is very unfamiliar to me and makes the material difficult to follow and relate to my real world problems. Speaking of software development in general, advice given with the assumptions of large projects isn't always straightforward to apply to my own, smaller endeavors. Summary So my question is: What are some resources to learn about unit testing, for a hobbyist, self-taught programmer without much formal training? Ideally, I'm looking for a short and simple "bible of unit testing" which I can commit to memory, and then apply systematically by repeatedly asking myself "is this test following the bible of testing closely enough?" and then amending discrepancies if it doesn't.

    Read the article

  • Linux fsck.ext3 says "Device or resource busy" although I did not mount the disk.

    - by matnagel
    I am running an ubuntu 8.04 server instance with a 8GB virtual disk on vmware 1.0.9. For disk maintenance I made a copy of the virtual disk (by making a copy of the 2 vmdk files of sda on the stopped vm on the host) and added it to the original vm. Now this vm has it's original virtual disk sda plus a 1:1 copy (sdd). There are 2 additional disk sdb and sdc which I ignore.) I would expect sdb not to be mounted when I start the vm. So I try tp do a ext2 fsck on sdd from the running vm, but it reports fsck reported that sdb was mounted. $ sudo fsck.ext3 -b 8193 /dev/sdd e2fsck 1.40.8 (13-Mar-2008) fsck.ext3: Device or resource busy while trying to open /dev/sdd Filesystem mounted or opened exclusively by another program? The "mount" command does not tell me sdd is mounted: $ sudo mount /dev/sda1 on / type ext3 (rw,relatime,errors=remount-ro) proc on /proc type proc (rw,noexec,nosuid,nodev) /sys on /sys type sysfs (rw,noexec,nosuid,nodev) varrun on /var/run type tmpfs (rw,noexec,nosuid,nodev,mode=0755) varlock on /var/lock type tmpfs (rw,noexec,nosuid,nodev,mode=1777) udev on /dev type tmpfs (rw,mode=0755) devshm on /dev/shm type tmpfs (rw) devpts on /dev/pts type devpts (rw,gid=5,mode=620) /dev/sdc1 on /mnt/r1 type ext3 (rw,relatime,errors=remount-ro) /dev/sdb1 on /mnt/k1 type ext3 (rw,relatime,errors=remount-ro) securityfs on /sys/kernel/security type securityfs (rw) When I ignore the warning and continue the fsck, it reported many errors. How do I get this under control? Is there a better way to figure out if sdd is mounted? Or how is it "busy? How to unmount it then? How to prevent ubuntu from automatically mounting. Or is there something else I am missing? Also from /var/log/syslog I cannot see it is mounted, this is the last part of the startup sequence: kernel: [ 14.229494] ACPI: Power Button (FF) [PWRF] kernel: [ 14.230326] ACPI: AC Adapter [ACAD] (on-line) kernel: [ 14.460136] input: PC Speaker as /devices/platform/pcspkr/input/input3 kernel: [ 14.639366] udev: renamed network interface eth0 to eth1 kernel: [ 14.670187] eth1: link up kernel: [ 16.329607] input: ImPS/2 Generic Wheel Mouse as /devices/platform/i8042/serio1/ kernel: [ 16.367540] parport_pc 00:08: reported by Plug and Play ACPI kernel: [ 16.367670] parport0: PC-style at 0x378, irq 7 [PCSPP,TRISTATE] kernel: [ 19.425637] NET: Registered protocol family 10 kernel: [ 19.437550] lo: Disabled Privacy Extensions kernel: [ 24.328857] loop: module loaded kernel: [ 24.449293] lp0: using parport0 (interrupt-driven). kernel: [ 26.075499] EXT3 FS on sda1, internal journal kernel: [ 28.380299] kjournald starting. Commit interval 5 seconds kernel: [ 28.381706] EXT3 FS on sdc1, internal journal kernel: [ 28.381747] EXT3-fs: mounted filesystem with ordered data mode. kernel: [ 28.444867] kjournald starting. Commit interval 5 seconds kernel: [ 28.445436] EXT3 FS on sdb1, internal journal kernel: [ 28.445444] EXT3-fs: mounted filesystem with ordered data mode. kernel: [ 31.309766] eth1: no IPv6 routers present kernel: [ 35.054268] ip_tables: (C) 2000-2006 Netfilter Core Team mysqld_safe[4367]: started mysqld[4370]: 100124 14:40:21 InnoDB: Started; log sequence number 0 10130914 mysqld[4370]: 100124 14:40:21 [Note] /usr/sbin/mysqld: ready for connections. mysqld[4370]: Version: '5.0.51a-3ubuntu5.4' socket: '/var/run/mysqld/mysqld.sock' port: 3 /etc/mysql/debian-start[4417]: Upgrading MySQL tables if necessary. /etc/mysql/debian-start[4422]: Looking for 'mysql' in: /usr/bin/mysql /etc/mysql/debian-start[4422]: Looking for 'mysqlcheck' in: /usr/bin/mysqlcheck /etc/mysql/debian-start[4422]: This installation of MySQL is already upgraded to 5.0.51a, u /etc/mysql/debian-start[4436]: Checking for insecure root accounts. /etc/mysql/debian-start[4444]: Checking for crashed MySQL tables.

    Read the article

  • MySQL InnoDB Corruption after power outage, possible to recover?

    - by Tim Hackett
    Hey Guys, I recently started trying to get Redmine up and running after a power outage that seems to have corrupted our InnoDB database in MySQL. Redmine had an extensive set of documentation that I would like to get even if redmine isn't able to run. The service fails on startup. I have tried inserting innodb_force_recovery = 4 per the documentation from the url in the error log. (also tried 1 thru 6 as I have backed up all directories after the corruption) I have verified through "mysqld-nt --print-defaults" that it is starting with the recovery option in the params. The machine is running Windows Server 2003 SP2, Xeon E5335 with 2GB RAM, MySQL is not mirrored to another machine, nor is the machine a mirror. I do not have any backups because the previous person did not set them up. Here is the error log: InnoDB: The log sequence number in ibdata files does not match InnoDB: the log sequence number in the ib_logfiles! 100308 14:50:01 InnoDB: Database was not shut down normally! InnoDB: Starting crash recovery. InnoDB: Reading tablespace information from the .ibd files... InnoDB: Restoring possible half-written data pages from the doublewrite InnoDB: buffer... 100308 14:50:02 InnoDB: Error: page 7 log sequence number 0 935521175 InnoDB: is in the future! Current system log sequence number 0 933419020. InnoDB: Your database may be corrupt or you may have copied the InnoDB InnoDB: tablespace but not the InnoDB log files. See InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: for more information. 100308 14:50:02 InnoDB: Error: page 2 log sequence number 0 935517607 InnoDB: is in the future! Current system log sequence number 0 933419020. InnoDB: Your database may be corrupt or you may have copied the InnoDB InnoDB: tablespace but not the InnoDB log files. See InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: for more information. 100308 14:50:02 InnoDB: Error: page 11 log sequence number 0 935517607 InnoDB: is in the future! Current system log sequence number 0 933419020. InnoDB: Your database may be corrupt or you may have copied the InnoDB InnoDB: tablespace but not the InnoDB log files. See InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: for more information. 100308 14:50:02 InnoDB: Error: page 5 log sequence number 0 972973045 InnoDB: is in the future! Current system log sequence number 0 933419020. InnoDB: Your database may be corrupt or you may have copied the InnoDB InnoDB: tablespace but not the InnoDB log files. See InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: for more information. 100308 14:50:02 InnoDB: Error: page 6 log sequence number 0 972984051 InnoDB: is in the future! Current system log sequence number 0 933419020. InnoDB: Your database may be corrupt or you may have copied the InnoDB InnoDB: tablespace but not the InnoDB log files. See InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: for more information. 100308 14:50:02 InnoDB: Error: page 1577 log sequence number 0 972737368 InnoDB: is in the future! Current system log sequence number 0 933419020. InnoDB: Your database may be corrupt or you may have copied the InnoDB InnoDB: tablespace but not the InnoDB log files. See InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: for more information. InnoDB: Error: trying to access page number 4294965119 in space 0, InnoDB: space name .\ibdata1, InnoDB: which is outside the tablespace bounds. InnoDB: Byte offset 0, len 16384, i/o type 10. InnoDB: If you get this error at mysqld startup, please check that InnoDB: your my.cnf matches the ibdata files that you have in the InnoDB: MySQL server. 100308 14:50:02InnoDB: Assertion failure in thread 960 in file .\fil\fil0fil.c line 3959 InnoDB: We intentionally generate a memory trap. InnoDB: Submit a detailed bug report to http://bugs.mysql.com. InnoDB: If you get repeated assertion failures or crashes, even InnoDB: immediately after the mysqld startup, there may be InnoDB: corruption in the InnoDB tablespace. Please refer to InnoDB: http://dev.mysql.com/doc/refman/5.0/en/forcing-recovery.html InnoDB: about forcing recovery. 100308 14:50:02 [ERROR] mysqld-nt: Got signal 11. Aborting! 100308 14:50:02 [ERROR] Aborting 100308 14:50:02 [Note] mysqld-nt: Shutdown complete

    Read the article

  • cf3 Can't stat ... in files.copyfrom promise

    - by Xerxes
    On the client: # cf-agent -KIv ... cf3 -> Handling file existence constraints on /etc/cfengine3 cf3 -> Copy file /etc/cfengine3 from /srv/cfengine/sysconf/server/inputs check cf3 No existing connection to 172.31.69.83 is established... cf3 Set cfengine port number to 5308 = 5308 cf3 -> Connect to 172.31.69.83 = 172.31.69.83 on port 5308 cf3 LastSaw host 172.31.69.83 now cf3 Loaded /var/lib/cfengine3/ppkeys/root-172.31.69.83.pub cf3 .....................[.h.a.i.l.]................................. cf3 Strong authentication of server=172.31.69.83 connection confirmed cf3 Server returned error: Unspecified server refusal (see verbose server output) cf3 Can't stat /srv/cfengine/sysconf/server/inputs in files.copyfrom promise cf3 ?> defining promise result class Cfengine_Inputs_Updated_Failed .... cf3 ......................................................... cf3 Promise handle: cf3 Promise made by: [cf-agent.cf ] FAILED 172.31.69.83:///srv/cfengine/sysconf/server/inputs -> localhost:///etc/cfengine3 However, on the server (172.31.69.83), there's no reason why it can't stat the directory: cyrus:/srv/cfengine/sysconf/server# ls -l /srv/cfengine/sysconf/server/inputs total 52 -rw-r--r-- 1 root root 2142 Sep 6 21:54 cf-agent.cf -rw-r--r-- 1 root root 831 Sep 6 18:31 cf-execd.cf -rw-r--r-- 1 root root 4517 Sep 6 21:44 cf-serverd.cf -rw-r--r-- 1 root root 3082 Sep 6 21:44 dns.cf -rw-r--r-- 1 root root 2028 Sep 6 15:12 failsafe.cf -rw-r--r-- 1 root root 5966 Sep 6 21:44 ldap-masters.cf -rw-r--r-- 1 root root 4380 Sep 6 18:31 ldap-security.cf -rw-r--r-- 1 root root 2735 Sep 6 08:21 lib-core.cf -rw-r--r-- 1 root root 1506 Sep 6 21:45 lib-utils.cf -rw-r--r-- 1 root root 2635 Sep 6 20:27 lib-vars.cf -rw-r--r-- 1 root root 2057 Sep 3 17:46 nss.cf -rw-r--r-- 1 root root 1472 Sep 6 18:31 packages.cf -rw-r--r-- 1 root root 1257 Sep 6 18:01 pam-security.cf -rw-r--r-- 1 root root 4019 Sep 6 19:32 promises.cf -rw-r--r-- 1 root root 2808 Sep 3 17:22 site.cf -rw-r--r-- 1 root root 1670 Sep 6 18:31 sudo-security.cf -rw-r--r-- 1 root root 831 Sep 6 18:31 sys-security.cf -rw-r--r-- 1 root root 890 Sep 6 18:31 sys-users.cf cyrus:/srv/cfengine/sysconf/server# I don't see anything interesting server side either when running: /usr/sbin/cf-serverd -d4 --verbose --no-fork And the following does not have any complaints: /usr/sbin/cf-promises -v Any ideas? I'm running cfengine3 on debian, v3.0.5+dfsg-1 - and the cf-agent.cf file is as follows: bundle agent Update { files: linux:: "${cf3.path[inputs]}" action => immediate, move_obstructions => "true", depth_search => Recursive, copy_from => MirrorFrom( "${cf3.host[server]}", "${cf3.path[scm-inputs]}", "true", "0400" ), classes => DefineSoftClass("Cfengine_Inputs_Updated") ; "${cf3.path[sbin]}" comment => "Setting cf3 client sbin scripts: ${cf3.path[sbin]}/", action => immediate, depth_search => Recursive, copy_from => MirrorFrom( "${cf3.host[server]}", "${cf3.path[scm-cnt-scripts]}", "false", "0555" ) ; reports: Cfengine_Inputs_Updated:: "[cf-agent.cf ] Services:CFAgent:Inputs:Updated"; Cfengine_Inputs_Updated_Failed:: "[cf-agent.cf ] FAILED ${cf3.host[server]}://${cf3.path[scm-inputs]} -> localhost://${cf3.path[inputs]}"; } I lie, there is something interesting with a little more debugging... AccessControl(/srv/cfengine/sysconf/server/inputs) AccessControl, match(/srv/cfengine/sysconf/server/inputs,client.com.au) encrypt request=1 Examining rule in access list (/srv/cfengine/sysconf/server/inputs,/home/cfengine)? cf3 Host client.com.au denied access to /srv/cfengine/sysconf/server/inputs Unappending Host client.com.au denied access to /srv/cfengine/sysconf/server/inputs cf3 Access control in sync Unappending Access control in sync Transaction Send[t 59][Packed text] Attempting to send 67 bytes SendSocketStream, sent 67 cf3 From (host=client.com.au,user=root,ip=172.31.69.3) Unappending From (host=client.com.au,user=root,ip=172.31.69.3) cf3 REFUSAL of request from connecting host: (SYNCH 1283777156 STAT /srv/cfengine/sysconf/server/inputs) Unappending REFUSAL of request from connecting host: (SYNCH 1283777156 STAT /srv/cfengine/sysconf/server/inputs) RecvSocketStream(8) cf3 -> Accepting a connection I'll keep looking.

    Read the article

< Previous Page | 248 249 250 251 252 253 254 255 256 257 258 259  | Next Page >