Search Results

Search found 16056 results on 643 pages for 'visual studio 6'.

Page 253/643 | < Previous Page | 249 250 251 252 253 254 255 256 257 258 259 260  | Next Page >

  • How can I fill SQL Server table from excel only using sql query?

    - by Phsika
    How can I do that with Microsoft.ACE.OLEDB.12.0? CREATE TABLE [dbo].[Addresses_Temp] ( [FirstName] VARCHAR(20), [LastName] VARCHAR(20), [Address] VARCHAR(50), [City] VARCHAR(30), [State] VARCHAR(2), [ZIP] VARCHAR(10) ) GO INSERT INTO [dbo].[Address_Temp] ( [FirstName], [LastName], [Address], [City], [State], [ZIP] ) SELECT [FirstName], [LastName], [Address], [City], [State], [ZIP] FROM OPENROWSET('Microsoft.ACE.OLEDB.12.0', 'Excel 12.0;Database=C:\Source\Addresses.xlsx;IMEX=1', 'SELECT * FROM [Sayfa1$]') How can I do that?

    Read the article

  • Publishing my Website to my Local Disk Causes Exceptions to show Paths including my Local Disk

    - by coffeeaddict
    I've published my website many times. But didn't think about this though until I came across this issue. So I decided to publish my WAP project to a local folder on my C drive first. Then used FTP to upload it to my shared host on discountasp.net. I noticed during runtime that the stack trace was referencing that local folder still and erroring out. Anyone know what config settings are affected when publishing? Obviously something is still pointing to my local C drive and I've searched my entire solution and don't see why. Here's the runtime error I get when my code tries to run in discountasp.net's web server Cannot write into the public directory - check permissions Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: ScrewTurn.Wiki.PluginFramework.InvalidConfigurationException: Cannot write into the public directory - check permissions Source Error: An unhandled exception was generated during the execution of the current web request. Information regarding the origin and location of the exception can be identified using the exception stack trace below. Stack Trace: [InvalidConfigurationException: Cannot write into the public directory - check permissions] ScrewTurn.Wiki.SettingsStorageProvider.Init(IHostV30 host, String config) in C:\www\Wiki\Screwturn3_0_2_509\Core\SettingsStorageProvider.cs:90 ScrewTurn.Wiki.StartupTools.Startup() in C:\www\Wiki\Screwturn3_0_2_509\Core\StartupTools.cs:69 ScrewTurn.Wiki.Global.Application_BeginRequest(Object sender, EventArgs e) in C:\www\Wiki\Screwturn3_0_2_509\WebApplication\Global.asax.cs:29 System.Web.SyncEventExecutionStep.System.Web.HttpApplication.IExecutionStep.Execute() +68 System.Web.HttpApplication.ExecuteStep(IExecutionStep step, Boolean& completedSynchronously) +75 Discountasp says it's not a permission issue but obviously it is. I think /Wiki should work...but it's not. Here's my site viewed in FTP on discountasp.net's server:

    Read the article

  • SetCurrentDirectory timing out

    - by Callum
    Is it possible for the SetCurrentDirectory() to timeout if there is network slowdown preventing the directory from being accessed for some length of time? (In the order of 15-30 seconds...?) If so is the timeout configurable and where can it be set?

    Read the article

  • vsts load test datasource issues

    - by ashish.s
    Hello, I have a simple test using vsts load test that is using datasource. The connection string for the source is as follows <connectionStrings> <add name="MyExcelConn" connectionString="Driver={Microsoft Excel Driver (*.xls)};Dsn=Excel Files;dbq=loginusers.xls;defaultdir=.;driverid=790;maxbuffersize=4096;pagetimeout=20;ReadOnly=False" providerName="System.Data.Odbc" /> </connectionStrings> the datasource configuration is as follows and i am getting following error estError TestError 1,000 The unit test adapter failed to connect to the data source or to read the data. For more information on troubleshooting this error, see "Troubleshooting Data-Driven Unit Tests" (http://go.microsoft.com/fwlink/?LinkId=62412) in the MSDN Library. Error details: ERROR [42000] [Microsoft][ODBC Excel Driver] Cannot update. Database or object is read-only. ERROR [IM006] [Microsoft][ODBC Driver Manager] Driver's SQLSetConnectAttr failed ERROR [42000] [Microsoft][ODBC Excel Driver] Cannot update. Database or object is read-only. I wrote a test, just to check if i could create an odbc connection would work and that works the test is as follows [TestMethod] public void TestExcelFile() { string connString = ConfigurationManager.ConnectionStrings["MyExcelConn"].ConnectionString; using (OdbcConnection con = new OdbcConnection(connString)) { con.Open(); System.Data.Odbc.OdbcCommand objCmd = new OdbcCommand("SELECT * FROM [loginusers$]"); objCmd.Connection = con; OdbcDataAdapter adapter = new OdbcDataAdapter(objCmd); DataSet ds = new DataSet(); adapter.Fill(ds); Assert.IsTrue(ds.Tables[0].Rows.Count > 1); } } any ideas ?

    Read the article

  • Drop target - where do I register the COleDropTarget variable if the view class doesn't have OnCreat

    - by Harvey
    The MSDN site says: From your view class's function that handles the WM_CREATE message (typically OnCreate), call the new member variable's Register member function. Revoke will be called automatically for you when your view is destroyed. But I don't have an OnCreate function in the ChildView class. I do have OnCreate in the CMainFrame class. Can I register it there? What are the ramifications? PLEASE NOTE: I have it working for dropping files but I want to drop the text as a file, not at a cursor location like a text cut and paste, but rather I want the application to make a buffer to hold it, and I will treat it like a file. TIA, Harvey

    Read the article

  • Why does MSBuild fail from the command line where VS2008 succeeds?

    - by sundeep
    I have an ASP.NET solution that builds just fine from within VS2008. However , it fails when i do this : MSBUILD.exe c:\path-to-sln It fails with a CS0006 error ("Metadata file 'dll_name' could not be found"). It also fails when I try with a .csproj of a project within the solution. What is VS2008 doing that MSBuild is missing ? It is my understanding that VS knows about inter assembly dependencies that MSBuild cant. Is there any way I can inform MSBuild of these? (I need MSBuild to work from the command line because I am calling it from an MSBuild-Task from within CruiseControl.Net.) Thanks in Advance. :3) (I have looked at http://stackoverflow.com/questions/280559/how-to-get-cmd-line-build-command-for-vs-solution , but still dont get it)

    Read the article

  • VS 2008 does not understand .resource files

    - by Dmitry
    I'm trying to add globalization support to my C# application. According to MSDN, there should be one embedded resource file for neutral culture and satellite DLLs with resource files for other cultures. I've created 2 satellite DLLs without any problems and got my app to automatically load right one using ResourceManager. But I can't embed default neutral culture resource file into my executable. When I remove all satellite DLLs or set culture to some culture I don't have satellite DLL for, I get exception "Could not find any resources appropriate for the specified culture or the neutral culture." when application attempts to create ResourceManager. It looks like VS 2008 does not include my .resource file into main assembly. I've tried different ways to get resource file embedded: compiling it by resgen.exe from text file and adding it to the project; changing its name to add second .resources extension; creating .resx file with same name; etc. And I still don't see the way to get resource file embedded and used by ResourceManager - I'm having same exception. What is the right way to add default neutral culture resource file to application in VS 2008 ?

    Read the article

  • Delphi: Moving away from VSS

    - by Mohammed Nasman
    We are team of few Delphi developers who have been using VSS since years (I know it's a pity), but we don't use any of the advanced features of VCS, so it was working fine in many cases (but some times it was driving me crazy :( ). The good thing that we have with VSS that we use third-party plug-ings to integrate VSS with Delphi, which is working great, but now when our projects becomes larger, and we would like to move a way from VSS. I have looked at few other VCS (free and commercial) and found most of them seems be made for Linux guys, and you have to use command line for many admin work(I know I'm windows guy :P). What I'm looking for the new Version control that it should be easy to use and to maintain and Integrated nicely with Delphi IDE (D2007), or at least have a good UI for the Admins an developers.

    Read the article

  • VS 2010 web.config transformation

    - by Fabian Vilers
    Hi all, I need help on web.config transformation as I'm trying to do something not documented. My web.config has an empty connectionStrings element. In debug, I'd like the transformation tool to add a configSource="file.local" to the connectionStrings element. But in release, I'd like it to add a connectionString element. So, to summarize, I have <connectionStings> </connectionStings> And I need to transform it to <connectionStings configSource="file.local"> </connectionStings> And to: <connectionStings> <clear/> <add name="Abc" connectionSting="bla bla bla" provider="xxx" /> </connectionStings> Anybody has done this yet? Thanks in advance, Fabian

    Read the article

  • Should I be relying on WebTests for data validation?

    - by Alexander Kahoun
    I have a suite of web tests created for a web service. I use it for testing a particular input method that updates a SQL Database. The web service doesn't have a way to retrieve the data, that's not its purpose, only to update it. I have a validator that validates the response XML that the web service generates for each request. All that works fine. It was suggested by a teammate that I add data validation so that I check the database to see the data after the initial response validator runs and compare it with what was in the input request. We have a number of services and libraries that are separate from the web service I'm testing that I can use to get the data and compare it. The problem is that when I run the web test the data validation always fails even when the request succeeds. I've tried putting the thread to sleep between the response validation and the data validation but to no avail; It always gets the data from before the response validation. I can set a break point and visually see that the data has been updated in the DB, funny thing is when I step through it in debug with the breakpoint it does validate successfully. Before I get too much more into this issue I have to ask; Is this the purpose of web tests? Should I be able to validate data through service calls in this manner or am I asking too much of a web test and the response validation is as far as I should go?

    Read the article

  • SQL Azure and VS 2010B2 or SSMSE 2008

    - by Vulgrin
    Ok, I see that people have asked this question before, but I'm seeing some conflicting statements. Can I, or can I not, connect directly to my SQL Azure database from SSMSE 2008? I see posts from before November that the SSMS 2008 RC would be able to connect directly - so I don't understand why the newest SSMSE cannot connect. Is it just a problem with the Express version of SSMS? Where can I find the "non-Express" version, if there is one? I can connect to the database via the cancel and connect method - however, you don't get object explorer that way. I see that there are add-ons for VS.Net to allow you to explore the database but I wanted to do it with the base apps if possible. Thanks

    Read the article

  • How can i call method from class but this method implamented from any interface?

    - by Phsika
    i try to call base.Alan(); in HacimBul. But base. dont give intellisense alan method public double HacimBul() { throw new Exception(); //return base..... -- how can i see base.Alan(); } namespace interfaceClass { class Program { static void Main(string[] args) { } } interface Ikenar { double kenar { get; set; } } interface Iyukseklik { double yuksekli {get; set;} } interface IAlan { double Alan(); } interface IHacim { double Hacim(); } class Alan : Ikenar, IAlan { public double kenar { get; set; } double IAlan.Alan() { return kenar * kenar; } } class Hacim : Alan, Iyukseklik { public double kenar { get; set; } public double yuksekli { get; set; } public double HacimBul() { throw new Exception(); //return base..... -- how can i see base.Alan(); } } }

    Read the article

  • How can i call method from class but this method implemented from any interface?

    - by Phsika
    i try to call base.Alan(); in HacimBul. But base. dont give intellisense alan method public double HacimBul() { throw new Exception(); //return base..... -- how can i see base.Alan(); } namespace interfaceClass { class Program { static void Main(string[] args) { } } interface Ikenar { double kenar { get; set; } } interface Iyukseklik { double yuksekli {get; set;} } interface IAlan { double Alan(); } interface IHacim { double Hacim(); } class Alan : Ikenar, IAlan { public double kenar { get; set; } double IAlan.Alan() { return kenar * kenar; } } class Hacim : Alan, Iyukseklik { public double kenar { get; set; } public double yuksekli { get; set; } public double HacimBul() { throw new Exception(); //return base..... -- how can i see base.Alan(); } } }

    Read the article

  • Create MSI for slipstream SQL 2008 install

    - by Graham
    I am looking at creating an MSI that will check/install the prerequisites of SQL Server 2008 and after the prerequisites are installed I will start my slipstream 2008 install. I am currently trying to do this through VS 2008 Deployment Projects, but I cannot just simple add the folders of the SQL slipstream into the setup project without recreating the entire folder structure of the SQL install. So my questions are: Is this a possible to do through Deployment Projects? (if yes, please assist with links or help) Is there a better way to do this? (I would prefer not to use WISE)

    Read the article

  • Windows update breaks dlls?

    - by shoosh
    I'm compiling a project which uses multiple DLL and compiles with VS2008. After a recent windows update DLLs compiled on my computer stopped working on other computers. After some investigation it turned out that it updated the CRT redistributable library which I'm compiling with from version "9.0.21022.8" to version "9.0.30729.4148" This is evident from the Manifest file of the EXE i'm compiling. it contains the following: <dependency> <dependentAssembly> <assemblyIdentity type="win32" name="Microsoft.VC90.CRT" version="9.0.21022.8" processorArchitecture="amd64" publicKeyToken="1fc8b3b9a1e18e3b"></assemblyIdentity> </dependentAssembly> </dependency> <dependency> <dependentAssembly> <assemblyIdentity type="win32" name="Microsoft.VC90.CRT" version="9.0.30729.4148" processorArchitecture="amd64" publicKeyToken="1fc8b3b9a1e18e3b"></assemblyIdentity> </dependentAssembly> </dependency> Meaning it wants to use two different versions of the CRT at the same time. the second version is needed by the code which I'm compiling right now and the first version is needed by older dlls which were compiled a few weeks ago. In the computers where the application is deployed this becomes a problem since they get their CRT dll from a local folder called Microsoft.VC90.CRT and not from WinSXS. This folder can't contain two different versions of the dll. Is there a known solution to this issue or do I need to start compiling all of the other DLLs with the new CRT?

    Read the article

  • ASP.NET ASPX Designer question. Bug?

    - by Velika
    Check out this Screenshot. Shouldn't a hierarchy list of tags appear here? Usually it appears. Sometimes, the tag "appears" there but without text (but the tag object is there as evident when you hover over it.) Other times, like this, nothing appears. It's a usual feature to see the hierarchy or tags which gives me easily access to the tags from design view for easy altering in the properties window. I think too many developers love to do things the hard way and sludge thru tags in HTML view and hardly use this, but it frustrates me when it doesn't work all the time. Is it me? Nah....

    Read the article

  • VS2010 - RiaServices - A project with that name is already opened in the solution

    - by andrecarlucci
    Hello, The problem started after installing RiaServices Toolkit Dec 2010. If I unload the project and reload it again, I get this message, even on an empty Silverlight project (no changes made to the project file). "error : A project with that name is already opened in the solution." The solution has only 2 projects: the host (web) and the silverlight one. Any help is appreciated :) UPDATE: It only happens if I give the Silverlight project the same name as the solution.

    Read the article

  • PLKs and Web Service Software Factory

    - by Nix
    We found a bug in Web Service Software Factory a description can be found here. There has been no updates on it so we decided to download the code and fix it ourself. Very simple bug and we patched it with maybe 3 lines of code. However* we have now tried to repackage it and use it and are finding that this is seemingly an impossible process. Can someone please explain to me the process of PLKs? I have read all about them but still don't understand what is really required to distribute a VS package. I was able to get it to load and run using a PLK obtained from here, but i am assuming that you have to be a partner to get a functional PLK that will be recognized on other peoples systems? Every time i try and install this on a different computer I get a "Package Load Failure". Is the reason I am getting errors because I am not using a partner key? Is there any other way around this? For instance is there any way we can have an "internal" VS package that we can distribute? Edit Files I had to change to get it to work. First run devenv PostInstall.proj Generate your plks and replace ##Package PLK## (.resx files) --Just note that package version is not the class name but is "Web Service Software Factory: Modeling Edition" -- And you need to remove the new lines from the key ProductDefinitionRegistryFragment.wxi line 1252(update version to whatever version you used in plk) Uncomment all // [VSShell::ProvideLoadKey("Standard", Constant in .tt files.

    Read the article

  • Accessing the selected element inside a templated textblock bound to a wpf listbox

    - by black sensei
    Hello good people , i'm trying to achieve a functionality but i'm don't know how to start it. I'm using vs 2008 sp1 and i'm consuming a webservice which returns a collection (is contactInfo[]) that i bind to a ListBox with little datatemplate on it. <ListBox Margin="-146,-124,-143,-118.808" Name="contactListBox" MaxHeight="240" MaxWidth="300" MinHeight="240" MinWidth="300"> <ListBox.ItemTemplate> <DataTemplate> <TextBlock> <CheckBox Name="contactsCheck" Uid="{Binding fullName}" Checked="contacts_Checked" /><Label Content="{Binding fullName}" FontSize="15" FontWeight="Bold"/> <LineBreak/> <Label Content="{Binding mobile}" FontSize="10" FontStyle="Italic" Foreground="DimGray" /> <Label Content="{Binding email}" FontStyle="Italic" FontSize="10" Foreground="DimGray"/> </TextBlock> </DataTemplate> </ListBox.ItemTemplate> </ListBox> Every works fine so far. so When a checkbox is checked i'll like to access the information of the labels (either the) belonging to the same row or attached to it and append the information to a global variable for example (for each checkbox checked). My problem right now is that i don't know how to do that. Can any one shed some light on how to do that? if you notice Checked="contacts_Checked" that's where i planned to perform the operations. thanks for reading and helping out

    Read the article

  • What code have you written with #pragma you found useful?

    - by Xavier Ho
    I've never understood the need of #pragma once when #ifndef #define #endif always works. I've seen the usage of #pragma comment to link with other files , but setting up the compiler settings was easier with an IDE. What are some other usages of #pragma that is useful, but not widely known? Edit: I'm not just after a list of #pragma directives. Perhaps I should rephrase this question a bit more: What code have you written with #pragma you found useful?

    Read the article

  • Logging errors in SCSF

    - by WF
    I'm quite new to SCSF. So, I'm developping a SCSF Winforms in C# (using May 2007 version in VSNet 2005 Fwk2.0, I can't use new version). I've implemented a Business module. What is the best practise to log errors? I've configured the Logging Application Block. But how to use that ? Thanks for answers

    Read the article

  • Possible mem leak?

    - by LCD Fire
    I'm new to the concept so don't be hard on me. why doesn't this code produce a destructor call ? The names of the classes are self-explanatory. The SString will print a message in ~SString(). It only prints one destructor message. int main(int argc, TCHAR* argv[]) { smart_ptr<SString> smt(new SString("not lost")); new smart_ptr<SString>(new SString("but lost")); return 0; } Is this a memory leak? The impl. for smart_ptr is from here edited: //copy ctor smart_ptr(const smart_ptr<T>& ptrCopy) { m_AutoPtr = new T(ptrCopy.get()); } //overloading = operator smart_ptr<T>& operator=(smart_ptr<T>& ptrCopy) { if(m_AutoPtr) delete m_AutoPtr; m_AutoPtr = new T(*ptrCopy.get()); return *this; }

    Read the article

  • CIL and JVM Little endian to big endian in c# and java

    - by Haythem
    Hello, I am using on the client C# where I am converting double values to byte array. I am using java on the server and I am using writeDouble and readDouble to convert double values to byte arrays. The problem is the double values from java at the end are not the double values at the begin giving to c# writeDouble in Java Converts the double argument to a long using the doubleToLongBits method , and then writes that long value to the underlying output stream as an 8-byte quantity, high byte first. DoubleToLongBits Returns a representation of the specified floating-point value according to the IEEE 754 floating-point "double format" bit layout. The Program on the server is waiting of 64-102-112-0-0-0-0-0 from C# to convert it to 1700.0 but he si becoming 0000014415464 from c# after c# converted 1700.0 this is my code in c#: class User { double workingStatus; public void persist() { byte[] dataByte; using (MemoryStream ms = new MemoryStream()) { using (BinaryWriter bw = new BinaryWriter(ms)) { bw.Write(workingStatus); bw.Flush(); bw.Close(); } dataByte = ms.ToArray(); for (int j = 0; j < dataByte.Length; j++) { Console.Write(dataByte[j]); } } public double WorkingStatus { get { return workingStatus; } set { workingStatus = value; } } } class Test { static void Main() { User user = new User(); user.WorkingStatus = 1700.0; user.persist(); } thank you for the help.

    Read the article

< Previous Page | 249 250 251 252 253 254 255 256 257 258 259 260  | Next Page >