Search Results

Search found 9235 results on 370 pages for 'disk cloning'.

Page 254/370 | < Previous Page | 250 251 252 253 254 255 256 257 258 259 260 261  | Next Page >

  • How to partition and format multiple disks using a batch script?

    - by chandu
    I am trying to format 'n' number of disks using a batch script. My script goes like this. diskpart /s "abc.txt" where abc.txt is: sel disk 1 create part primary format FS=NTFS label=label2 quick compress My Problem here is I want to 'loop' the commands in abc.txt for the number of disks that exists. But I cannot send an argument like %1 to abc.txt file as it is a .txt file. and my diskpart /s can only take a .txt file as an argument. how to overcome this... could anybody please help?

    Read the article

  • How to choose my own filename format for subscribed podcast files?

    - by meomaxy
    I subscribe to several podcasts where the filenames of the downloaded mp3 files have no particular pattern to them. When I copy the directory of accumulated mp3 files into my mp3 player, the files play in alphabetical order. What I really want is to play the files chronologically by release date. I currently use iTunes on Windows XP to download the files. What I do now is manually rename the files, adding the date in YYYYMMDD format to the start of each filename so that an alphabetical listing of files will correspond to their chronological order when I listen to them later in PocketTunes on my Palm Centro. Is there some way to get the release date into the filename automatically? If so, I could automate or possibly skip the file renaming step. I would switch from iTunes to something else if that would solve my problem. The file creation time on my local disk isn't a reliable indicator because sometimes I download a few days worth of content at one time, and the files don't necessarily get downloaded in chronological order.

    Read the article

  • Dell Dimension running Fedora12 does a "Sleeping Beauty" and I am not a "handsome prince"!

    - by Jim Dobbs
    Dell Dimension 2350 with a Pentium IV processor and integrated video and network chips running Fedora12 does a "Sleeping Beauty" and I, apparently, am not am not a "handsome prince"! The system puts video and network to sleep and it will not wakeup. I have heard of this problem on laptops, but this is a tower. Any ideas or help is appreciated. I tried to ping the network card from another system and ping fails. The logs indicate that the system continues to be active. Pressing keyboard short-cut keys makes the disk light blink but neither the video or network card comes alive. Failing all else, are there any Linux commands that I could schedule in cron to pulse video and network adapters hourly that will keep them awake? Or, should I wait on Fedora13? Before this machine, I built a Dimension 2400 with Pentium IV and it had the same problem. Fedora9 on the same hardware is fine.

    Read the article

  • Laptop harddisk produces clicking sound

    - by Alfred James
    This happens when I am booting up into windows, shutdown or things in which I access the harddrive excessively. It doesn't happen all the time. I have checked it with "Crystal disk Info" and it displays no problem, and shows HDD to perfectly fine. Should I be worried about my HDD? I have Hitachi HDD in laptop. Some times my harddrive temps reach upto 43C while watching movies or playing games. What are the normal temps, which are safe for HDD to operate and increase the lifetime of HDD. Thanks

    Read the article

  • Improving TCP performance over a gigabit network lots of connections and high traffic for storage and streaming services

    - by Linux Guy
    I have two servers, Both servers hardware Specification are Processor : Dual Processor RAM : over 128 G.B Hard disk : SSD Hard disk Outging Traffic bandwidth : 3 Gbps network cards speed : 10 Gbps Server A : for Encoding videos Server B : for storage videos andstream videos over web interface like youtube The inbound bandwidth between two servers is 10Gbps , the outbound bandwidth internet bandwidth is 500Mpbs Both servers using public ip addresses in public and private network Both servers transfer and connection on nginx port , and the server B used for streaming media , like youtube stream videos Both servers in same network , when i do ping from Server A to Server B i got high time latency above 1.0ms , the time range time=52.7 ms to time=215.7 ms - This is the output of iftop utility 353Mb 707Mb 1.04Gb 1.38Gb 1.73Gb mqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqq server.example.com => ip.address 6.36Mb 4.31Mb 1.66Mb <= 158Kb 94.8Kb 35.1Kb server.example.com => ip.address 1.23Mb 4.28Mb 1.12Mb <= 17.1Kb 83.5Kb 21.9Kb server.example.com => ip.address 395Kb 3.89Mb 1.07Mb <= 6.09Kb 109Kb 28.6Kb server.example.com => ip.address 4.55Mb 3.83Mb 1.04Mb <= 55.6Kb 45.4Kb 13.0Kb server.example.com => ip.address 649Kb 3.38Mb 1.47Mb <= 9.00Kb 38.7Kb 16.7Kb server.example.com => ip.address 5.00Mb 3.32Mb 1.80Mb <= 65.7Kb 55.1Kb 29.4Kb server.example.com => ip.address 387Kb 3.13Mb 1.06Mb <= 18.4Kb 39.9Kb 15.0Kb server.example.com => ip.address 3.27Mb 3.11Mb 1.01Mb <= 81.2Kb 64.5Kb 20.9Kb server.example.com => ip.address 1.75Mb 3.08Mb 2.72Mb <= 16.6Kb 35.6Kb 32.5Kb server.example.com => ip.address 1.75Mb 2.90Mb 2.79Mb <= 22.4Kb 32.6Kb 35.6Kb server.example.com => ip.address 3.03Mb 2.78Mb 1.82Mb <= 26.6Kb 27.4Kb 20.2Kb server.example.com => ip.address 2.26Mb 2.66Mb 1.36Mb <= 51.7Kb 49.1Kb 24.4Kb server.example.com => ip.address 586Kb 2.50Mb 1.03Mb <= 4.17Kb 26.1Kb 10.7Kb server.example.com => ip.address 2.42Mb 2.49Mb 2.44Mb <= 31.6Kb 29.7Kb 29.9Kb server.example.com => ip.address 2.41Mb 2.46Mb 2.41Mb <= 26.4Kb 24.5Kb 23.8Kb server.example.com => ip.address 2.37Mb 2.39Mb 2.40Mb <= 28.9Kb 27.0Kb 28.5Kb server.example.com => ip.address 525Kb 2.20Mb 1.05Mb <= 7.03Kb 26.0Kb 12.8Kb qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq TX: cum: 102GB peak: 1.65Gb rates: 1.46Gb 1.44Gb 1.48Gb RX: 1.31GB 24.3Mb 19.5Mb 18.9Mb 20.0Mb TOTAL: 103GB 1.67Gb 1.48Gb 1.46Gb 1.50Gb I check the transfer speed using iperf utility From Server A to Server B # iperf -c 0.0.0.2 -p 8777 ------------------------------------------------------------ Client connecting to 0.0.0.2, TCP port 8777 TCP window size: 85.3 KByte (default) ------------------------------------------------------------ [ 3] local 0.0.0.1 port 38895 connected with 0.0.0.2 port 8777 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.8 sec 528 KBytes 399 Kbits/sec My Current Connections in Server B # netstat -an|grep ":8777"|awk '/tcp/ {print $6}'|sort -nr| uniq -c 2072 TIME_WAIT 28 SYN_RECV 1 LISTEN 189 LAST_ACK 139 FIN_WAIT2 373 FIN_WAIT1 3381 ESTABLISHED 34 CLOSING Server A Network Card Information Settings for eth0: Supported ports: [ TP ] Supported link modes: 100baseT/Full 1000baseT/Full 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: Yes Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: Yes Speed: 10000Mb/s Duplex: Full Port: Twisted Pair PHYAD: 0 Transceiver: external Auto-negotiation: on MDI-X: Unknown Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes Server B Network Card Information Settings for eth2: Supported ports: [ FIBRE ] Supported link modes: 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: No Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: No Speed: 10000Mb/s Duplex: Full Port: Direct Attach Copper PHYAD: 0 Transceiver: external Auto-negotiation: off Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes ifconfig server A eth0 Link encap:Ethernet HWaddr 00:25:90:ED:9E:AA inet addr:0.0.0.1 Bcast:0.0.0.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1202795665 errors:0 dropped:64334 overruns:0 frame:0 TX packets:2313161968 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:893413096188 (832.0 GiB) TX bytes:3360949570454 (3.0 TiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:2207544 errors:0 dropped:0 overruns:0 frame:0 TX packets:2207544 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:247769175 (236.2 MiB) TX bytes:247769175 (236.2 MiB) ifconfig Server B eth2 Link encap:Ethernet HWaddr 00:25:90:82:C4:FE inet addr:0.0.0.2 Bcast:0.0.0.2 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:39973046980 errors:0 dropped:1828387600 overruns:0 frame:0 TX packets:69618752480 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3013976063688 (2.7 TiB) TX bytes:102250230803933 (92.9 TiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:1049495 errors:0 dropped:0 overruns:0 frame:0 TX packets:1049495 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:129012422 (123.0 MiB) TX bytes:129012422 (123.0 MiB) Netstat -i on Server B # netstat -i Kernel Interface table Iface MTU Met RX-OK RX-ERR RX-DRP RX-OVR TX-OK TX-ERR TX-DRP TX-OVR Flg eth2 9000 0 42098629968 0 2131223717 0 73698797854 0 0 0 BMRU lo 65536 0 1077908 0 0 0 1077908 0 0 0 LRU I Turn up send/receive buffers on the network card to 2048 and problem still persist I increase the MTU for server A and problem still persist and i increase the MTU for server B for better connectivity and transfer speed but it couldn't transfer at all The problem is : as you can see from iperf utility, the transfer speed from server A to server B slow when i restart network service in server B the transfer in server A at full speed, after 2 minutes , it's getting slow How could i troubleshoot slow speed issue and fix it in server B ? Notice : if there any other commands i should execute in servers for more information, so it might help resolve the problem , let me know in comments

    Read the article

  • SCSI vs SATA? Is SCSI "actually" better?

    - by earlz
    Well, I was talking with a guy about servers the other day. I was a bit shocked whenever I asked him if there was any significant difference between SCSI and SATA and why he always uses SCSI. (note, I'm not sure if by SCSI he meant SAS) He told me that SCSI is always faster and that the drives are always more reliable.. I mean, this seems like a bold statement. He told me something about how SCSI will always be faster than SATA because the OS sends the SCSI (controller?) a request to get a file and it will build the file inside of the SCSI controller, instead of searching all over the disk.. which I do not understand how that would work, so I figure it is BS. SAS and SATA currently have equivalent data rate speeds.. Is there any true backing for his reasoning that SCSI is always faster and more reliable than SATA?

    Read the article

  • What parameters to mdadm, to re-create md device with payload starting at 0x22000 position on backing storage?

    - by Adam Ryczkowski
    I try to recover from mdadm raid disaster, which happened when moving from ubuntu server 10.04 to 12.04. I know the correct order of devices from dmesg log, but given this information, I still cannot access the data. The superblocks look messy; the mdadm --examine for each disk is on this question on askubuntu By inspecting the raw contents of backing storage, I found the beginning of my data (the LUKS container in my case) at position 0x22000 relative to the beginning of the first partition in the raid. Question: What is the combination of options issued to "mdadm --create" to re-create mdadm that starts with the given offset? Bitmap size? PS. The relevant information from syslog when the system was healthy are pasted here.

    Read the article

  • Monitoring over Time with Nagios: How?

    - by David
    Nagios in its standard usage monitors with point-in-time checks: either something is - or is not - true. Other tools like SGI's PCP, HP's MeasureWare, and SEC provide monitoring over time - monitoring things like average disk access time over the last five minutes, or other similar items. Is there anything like this for Nagios? I'm already running NDOUtils, which seems like a natural source for such data. I'd like to have something that would monitor and fire off alarms based on a time-based check using historical data. Is there anything like this for Nagios?

    Read the article

  • Dell Dimension 2350 with a Pentium IV processor and integrated video and network chips running Fedor

    - by Jim Dobbs
    Dell Dimension 2350 with a Pentium IV processor and integrated video and network chips running Fedora12 does a "Sleeping Beauty" and I, apparently, am not am not a "handsome prince"! The system puts video and network to sleep and it will not wakeup. I have heard of this problem on laptops, but this is a tower. Any ideas or help is appreciated. I tried to ping the network card from another system and ping fails. The logs indicate that the system continues to be active. Pressing keyboard short-cut keys makes the disk light blink but neither the video or network card comes alive. Failing all else, are there any Linux commands that I could schedule in cron to pulse video and network adapters hourly that will keep them awake? Or, should I wait on Fedora13? Before this machine, I built a Dimension 2400 with Pentium IV and it had the same problem. Fedora9 on the same hardware is fine.

    Read the article

  • Scheduled service/script/batch file to move files on condition of other files with similar filenames in same directory on windows

    - by ilasno
    On Windows Server (Data Center? 2008?), i'm trying to set up a scheduled task that will: Within a particular directory For every file in it If there exists (in the same directory) 2 files with similar names (actually the same name with extra extensions tagged on, ie. 'file1.mov' would need both 'file1.mov.flv' AND 'file1.mov.mpg' to exist), then move the file to another directory on a different disk. Following is what i have so far for a batch file, but i'm struggling. I'm also open to another technique/mechanism. @setlocal enableextensions enabledelayedexpansion @echo off SET MoveToDirectory=M:\_SourceVideosFromProduction ECHO MoveToDirectory=%MoveToDirectory% pause for /r %%i in (*) do ( REM ECHO %%i REM ECHO %%~nxi REM ECHO %%~ni REM ECHO filename=%filename% REM SET CurrentFilename=%%~ni REM ECHO CurrentFilename=%CurrentFilename% IF NOT %%~ni==__MoveSourceFiles ( IF NOT x%%%~ni:\.=%==x%%%~ni% DO ( REM SET HasDot=0 REM FOR /F %%g IN %filename% do ( REM IF %%g==. ( ECHO %filename% REM ) ) ) ) pause

    Read the article

  • VMWare guest OS is not using full hard drive space

    - by syuusuke
    Hey everyone, I'm wondering if you can give me some insight on how to figure this out. I've recently virtualized a w2k3 server that had 10GB C:\ drive size. Once I finished virtualizing it, I expanded the disk to 20GB for C:\ and within guest OS (W2K3) computer management settings, you can see it recognizes as 20GB partition C:. But for some reason, if I opened windows explorer and see the properties of C:\, it will only show total size of 10GB. Does anyone know how to solve this or even had this problem before?

    Read the article

  • Google App Engine says "Must authenticate first." while trying to deploy any app

    - by Oleksandr Bolotov
    Google App Engine says "Must authenticate first." while trying to deploy any app: me@myhost /opt/google_appengine $ python appcfg.py update ~/sda2/workspace/lyapapam/ Application: lyapapam; version: 1. Server: appengine.google.com. Scanning files on local disk. Scanned 500 files. Scanned 1000 files. Initiating update. Email: <my_email_was_here>@gmail.com Password for <my_email_was_here>@gmail.com: Error 401: --- begin server output --- Must authenticate first. --- end server output --- We are getting this message with any appliation and under any developer account avialable to us That's what we have installed: App Engine SDK - 1.3.2 PIL - 1.1.7 Python - 2.5.5 pip - 0.6.3 ssl - 1.15 wsgiref - 0.1.2 So, what can it be? Is it well known problem?

    Read the article

  • Windows Server 2003 not automatically assigning drive letter to external drives

    - by Chris
    My newly rebuilt Windows Server 2003 doesn't automatically assign drive letters to external usb devices. I have to manually open the Disk Management Console and assign it a drive letter every time. It does this with two different drives in all USB ports. I have been doing some reading and I don't have any network drives, I have also already tried USBDLM and it doesn't seem to have made any difference. Specs: ProLiant ML150 G5 with Windows 2003 Enterprise and all updates installed. Any ideas on what I can try to resolve this problem would be greatly appreciated. Chris

    Read the article

  • Splitting a drive which has layout as mirrored and type as dynamic

    - by shiva
    I have a C drive/volume in my server with layout = mirror and type =dynamic and status as healthy(boot,pagefile,crashdump). I have some questions regarding this configuration: I think it is a raid configuration.Please correct me if I am wrong. I read that, mirroring is nothing but raid-1 configuration. All my software and OS is in this drive. I want my software to be in a separate drive, but I am not sure if I can create a separate drive from the above mentioned c drive. I want to know: a. If I can do it and how ?(using disk management) b. If this is a right approach ?

    Read the article

  • How to perform diagnostics (stress test) on HP Smartarray Controller

    - by pepoluan
    At my office, we have a server that we suspect its RAID controller (HP Smartarray) is failing. A cold boot, however, does not indicate anything. Can anyone recommend me a method to stress-test the controller? Symptoms that makes me suspect a failing controller: Disk access getting slower, queue getting longer Running dmesg on the XenServer console I see many messages similar to this one: end_request: I/O error, dev tda, sector 253655584 (the sector number is never the same) When we move the VM to another physical host, we no longer see the above message Running idle (without any running VM), the dmesg no longer emit the above message A search on Google indicated that the above message is most commonly associated with a failing SmartArray controller. How can I be sure that the SmartArray controller is failing?

    Read the article

  • My computer resets when i try to install Windows 7 (USB/DVD)

    - by Ranhiru
    I had a troublesome software starting up when Windows 7 was starting and i had no way to remove it because i couldn't log in to Windows. Not even safe mode. But i used Hiren's Boot CD to edit the registry to stop that software from starting up... But my efforts were not useful as Windows kept on going to an ultimate freeze just before the login screen should have been shown. And just freezes and I cannot do anything. So i decided heck with it and i now want to format the disk and reinstall a fresh copy of Windows 7. But now regardless of USB or DVD i use to boot the setup, it loads fine till you see the animating Windows and it just resets the laptop! Just plain resets! Hiren's Boot CD and Mini XP, strange enough but still works :( Any ideas what might be causing the laptop to reset in Windows 7 setup?

    Read the article

  • Freebsd 7.2: View firmware version for disks?

    - by Stefan Lasiewski
    I'm running FreeBSD 7.2, with Seagate Cheetah (Model ST####) drives. We are having some problems with the SCSI drives on these machines. Our vendor says that updating the firmware on the drives may fix the problems, and a firmware update did seem to fix some SCSI problems on another FreeBSD host. How can I view the firmware version of these drives? I tried some tips from nixCraft, but nothing has worked so far. In dmesg, I see the Make and Model, but In Linux, this information is often in /var/log/dmesg (Although /var/log/dmesg is sometimes out of date), or I often find this information with something like sudo lshw -class disk, lshal or dmidecode.

    Read the article

  • Restoring Box Sync (box.com) using physical media after OS reinstall

    - by sjrm
    I have my Box Folder on a different drive ( D: ) than my Operating System Drive ( C: ) I follow these instructions to set the local folder on the second drive. https://support.box.com/hc/en-us/articles/200852947-How-Can-I-Change-the-Default-Folder-Location-for-Box-Sync- I had to format and reinstall Windows 7, leaving the other drive (D: ) untouched. now i reinstalled Box Sync, and directed it to the same location where i already have all my files. However, Box Sync renamed the folder to (Box ([email protected]) ) as a bckup, and is downloading everything again. As i have like 30Gb of files, and it takes many hour to download them, i just want to use the files that i already have in my local disk. i tried copying all files again to the new local Box Folder, but files started to get duplicated. Is there any way to avoid downloading everything again each time i reinstall my OS ? Thanks

    Read the article

  • Windows 7 can't make back up

    - by J. Pablo Fernández
    I've been trying to get Windows 7 to make a backup for a week or so. I'm backing up to a local NAS and I'm getting this error: Windows Backup: Troubleshooting Options Check your backup Windows Backup could not create a zip file. This could be because the drive that Windows is installed on does not have enough space or it could be a temporary error. Make sure you have at least 400 MB of free space and try again. Backup time: 2009-09-07 14:48 Backup location: \VANGELIS\Shared\Backup\lennon\ Error code: 0x81000015 My local hard disk has 290GB free and my NAS has 200GB free. Any ideas what might be wrong?

    Read the article

  • Can a 32-bit RHEL4 userland work with a 64-bit kernel?

    - by James
    Is there a way to change an i386 RHEL4 machine to run an amd64 kernel, but ensure that it still builds software into same i386 binaries? On Debian this seems quite straightforward: just install an amd64 kernel (worst case, build one like this guy: http://www.debian-administration.org/users/jonesy/weblog/1) and prefix everything with "linux32". Then everything that considers uname -m will be unchanged, I just need to handle the few cases that consider uname -r. What is the Red Hat equivalent? Is the only way a full 64-bit installation on another disk and then chrooting back to the 32-bit system before anyone builds anything? (Even the best examples of that seem to be Debian-based.) Background: We make a large system that runs on (a variant of) i386 RHEL4. However, some of the larger RHEL build machines now have enough RAM that they might benefit from going 64-bit (for the kernel and maybe some of the bigger build steps). Our build system doesn't support cross-compilation.

    Read the article

  • Can't run Ubuntu from disc

    - by alex
    When I place the boot CD in my CD drive and boot from it, I get the Ubuntu menu. I have these options Try Ubuntu without any change to your computer Install Ubuntu Check disc for defects Test memory Boot from first hard disk I can use the cursor keys to select them, and I can push F1 for help etc. However, I can not select an option. I've highlighted the first and tried enter, space bar etc. I do have a KVM, so I plugged in a 2nd USB keyboard and tried it but no go either. I can push escape and then got to the prompt. Am I doing something wrong?

    Read the article

  • Setting up NIS/NFS on Mac OS 10.6

    - by evan
    We have an Ubuntu NIS/NFS server at work and we recently got a few new iMacs. Is there a way to set them up so they can use the linux user accounts and mount the shared nfs files? Are there any guides on how to do this? I've been googling with no success. I tried getting NFS to work by connecting to the server via the Disk Utility but after I run 'sudo automount' from the command line and ls the directory I tried to mount it to (Volumes/nfs) it gives a permissions error. If there isn't a way to do this, anyone know of any not to complicated ways to share user accounts and files between mac and linux computers (and even hypothetically a windows computer one day?) I know its kind a of huge question, but I'll greatly appreciate any advice on the topic. Thanks!

    Read the article

  • Authorization error when testing FTP to UNC

    - by user64204
    We have a Windows Server 2008 R2 with Active Directory (hereafter called DC) running as a domain controller on which we have IIS and an FTP site installed. We have a second Server 2008 (hereafter called SHARE) which is joined to that domain and has a disk shared as a network share (\\share\Office). That network share is used as the ftp's physical path on DC. We've tested the FTP from the IIS FTP configuration panel, by clicking on Basic Settings... then Test Settings.... When setting Administrator as a username with the Connect as... option, everything is fine: When no user is provided we can the below error: Q1: Could someone explain in more understandable terms what is written in the Details text area?

    Read the article

  • Slow Web Performance on two Windows 2008 R2 Terminal Servers

    - by Frank Owen
    We have two Windows 2008 R2 servers that we use for agents to log into to access our customers systems. Saturday morning we received complaints that on both servers the web is running horribly slow. This happens on all websites and the majority of the time the web site times out trying to load. Other users located at the same site but using their desktop machine do not see any issue. We have rebooted the boxes and checked settings and cannot find the cause. The CPU/Memory/Network/Disk Space use on the server is very low. I thought it might have been a MS update causing the issue but it appears the last update was applied in January. We have rebooted both boxes and I am in process of trying a different browser. Any ideas what could be causing this?

    Read the article

  • WSUS setup on ADS Domain Controller VM

    - by NickC
    How should I setup sharing/directory permissions to allow the following to work: VMHost - Hyper-V partition (not part of domain) ADServer - Active Directory Domain Controller running as guest VM on VMHost \VMHost\Updates disk share for WSUS to put the updates and other local files Problem is what permissions do I need to give to \VMHost\Updates to allow WSUS to work with this directory to avoid "The WSUS content directory is not accessible" error which I am currently seeing. As far as I can tell WSUS runs as "domain/Network Service" account. Question is without adding VMHost to the domain how do I give that user appropriate permissions to this directory? Is there a way that VMHost can be told to trust ADServer and then be able to use users accounts from there? Sort of relates to my other post here: Win 2012 Domain controller VM, should the Hyper-V host be part of the domain? Thanks, Nick

    Read the article

< Previous Page | 250 251 252 253 254 255 256 257 258 259 260 261  | Next Page >