  • What could be wrong with my VLAN?

    - by Matt
    I've got a VLAN 10 setup as a management VLAN. The management VLAN comes off port 48 and links to another set of switches that do not support VLAN's so it was I believe set up as an untagged access port. In the past this was a different brand of switch and this worked fine. However, since changing to the HP V1910-48G series I can't seem to get this working. I must point out that as far as I'm aware it is wired up properly (I can't check this physically as I'm working remote and have asked the tech who's got access to double check for me). Now I don't have a huge amount of experience with VLAN environments but AFAIK this is right. I've set the port 48 (linked to the management switches) as an untagged port with PVID 10 and access link type. Is this all I'd need to do from a configuration perspective to ensure all devices connected to port 48 would end up being on VLAN 10 and not needing to tag their frames. i.e. the tag would be added by the switch before being forwarded.

    Read the article

  • Stack Managed Switches over a distance

    - by Joel Coel
    We have several buildings with stacked switches, where the distance between the stacked units is considerable... separate floors, or at opposite ends of a hallway. They are 3Com switches that stack using cat6 cabling. These switches are coming up on 12 years old now, and as I look around at replacements it seems no one supports this scenario any more. Stacking switches want to use fiber links (it more for me to run and terminate the fiber stacking cables than to purchase the switch) or other custom cables that seem only intended to jump up to the next unit in a rack. What have others done to support stacking over a distance? I'm considering breaking up the stacked switches into separate managed entities and just bridging from the root switch in the buildings, but I'd really like to avoid that for what I hope are obvious reason. The closest thing I've found are from netgear that use hdmi cables for the stacking connection... I could try to support that by running an additional cat6 line and re-terminating both links into a single hdmi port, but I have concerns over that approach as well.

    Read the article

  • Network switches for LAN party

    - by guywhoneedsahand
    I am working on setting up the network for a small LAN party (less than 16 people). Most of them do not have wireless cards in their rigs, so I need to set up some way for everyone to a) play LAN games and b) access the internet. The LAN party will probably take place in my basement, where I have enough space. However, the basement is not wired up with the router which is actually on the floor above. I make a cantenna a while back that can boost the wireless performance of my computer significantly. How can I use this to provide internet and LAN to guests? My hope was that I could use a switch like this http://www.newegg.com/Product/Product.aspx?Item=N82E16833181166 for the LAN - but how can I give people access to the internet? Is there such thing as a network extender / 16-port switch? Obviously, the internet performance doesn't need to be super stellar, because the games will be using LAN - so I am looking to provide some usable internet for web browsing, and very high speed LAN for games. Thanks!

    Read the article

  • What differences are there between "home" switches and "professional" switches?

    - by pjreddie
    Our radio station uses a PtP wireless system to stream our radio and TV signals from our studio up a hill to our transmitter. We have been having problems with warbly sound and drop outs that come from some point in this system. An engineer that occasionally visits the station thinks it could be the switches we use on each side of the PtP wireless system to connect the PtP devices to the encoders and decoders and wants us to get two of these switches: http://www.amazon.com/Netgear-JGS516-ProSafe-16-Port-Ethernet/dp/B0002CWPOK/ref=dp_return_1 The encoder/decoder setup only streams 8Mbps total so it seems like the switches we have should not be stressed out, unless they are causing sufficient latency to degrade the performance of the encoder/decoder. At each end of the connection we only have 4 connections, is there any reason we couldn't get a cheaper, "home" quality switch like this: http://www.amazon.com/D-Link-DGS-1005G-5-Port-Gigabit-Desktop/dp/tech-data/B003X7TRWE/ref=de_a_smtd Is there a significant difference that we would notice in terms of latency between these two switches? How much does the quality of the switch actually matter in this scenario? Any help is appreciated, feel free to ask questions if anything needs clarification. Thanks

    Read the article

  • Seeing traffic destined for other people's servers in wireshark

    - by user350325
    I rent a dedicated server from a hosting provider. I ran wireshark on my server so that I could see incoming HTTP traffic that was destined to my server. Once I ran wireshark and filtered for HTTP I noticed a load of traffic, but most of it was not for stuff that was hosted on my server and had a destination IP address that was not mine, there were various source IP addresses. My immediate reaction was to think that somebody was tunnelling their HTTP traffic through my server somehow. However when I looked closer I noticed that all of this traffic was going to hosts on the same subnet and all of these IP addresses belonged to the same hosting provider that I was using. So it appears that wireshark was intercepting traffic destined for other customers who's servers are attached to the same part of the network as mine. Now I always assumed that on a switch based network that this should not happen as the switch will only send data to the required host and not to every box attached. I assume in this case that other customers would also be able to see data going to my server. As well as potential privacy concerns, this would surely make ARP poising easy and allow others to steal IP addresses (and therefor domains and websites)? It would seem odd that a network provider would configure the network in such a way. Is there a more rational explanation here?

    Read the article

  • Uninstalled server 2008 now router won't handle DHCP

    - by john
    My set up is this. server behind router, router has a server and switch connected to it with multiple computers. router used to serve DHCP and DNS, a couple of days ago installed AD, DNS and DHCP on the server, and the server gave out IP's. For various reasons we had to uninstall the domain on our server. I removed AD, DHCP and DNS from the roles and set the router back to serving DHCP and DNS. Now I can't get computers on the network. I reset my router back to factory defaults, and if I plug a computer directly into the router I can get a IP address, but all the computers behind the switch can't get an IP address and can't see the router. All my computers say unidentified network, and if I ping the router it says host is unreachable. On the other hand, my wireless devices are just fine and connect no problem. But for desktops, ipconfig /release doesn't release anything and /renew can't find a server to renew on. My router log shows several FIN scans but they are from innocuous websites (google, netgear) and it shows a couple of smurf attacks but they are all from my external IP. Any ideas? the server isn't even connected to the route right now, and all the computers are set for dynamic IP addresses.. I don't know what else to try? Any help?

    Read the article

  • Issues connecting to HP ProCurve switches

    - by BriGuy
    We are having a very strange issue trying to connect to our infrastructure switches via SSH. When you first try connecting to them, the switches will prompt for the password - and then just sit there after it is entered. If you create a second SSH session to the switch (while letting the first one remain open and just sitting there) it will let you log right in. The switches are doing the same thing with RADIUS and local authentication. The other strange part to all of this, is that about 10 switches started doing it all at the same time. As far as actual configuration of the switches, nothing has changed. Occasionally, one switch will start working like normal, but then stop again. These are all HP ProCurve managed switches, but all different models/firmware. Some switches that are not working are using the same firmware as others that are working. UPDATE: 20130312 I am also seeing this same behavior when trying to use telnet. The first telnet session just hangs there, and the second telnet session will let me log in. Rebooting the switches seems to get them working, but I still have 5 production switches that cannot easily be rebooted because of their production roles. Is anyone aware of anything else that can be switched on/off that may reset the logon for remote management or something like that?

    Read the article

  • Network using only switches

    - by mschultz
    So I'm not a network guy - but here's what I want to do - I have an existing network using wifi, which I like, and which is used to connect several computers to the internet. It is headed up by a router, which is in another part of the building. Three of those computers are in my office. All three have gigabit wired ethernet. I have a gigabit switch. Here's what I want to do: Build a 2nd network, out of just that switch, which allows all 3 computers to connect to each other (just to each other is fine, for this purpose, they need no internet). I have a distributed computing task (rendering high-quality fractal artwork, as it were), that requires the best connection speed to all 3 computers. I want them to be able to "talk to each other" as quickly as possible, with the fewest dropped packets (the dataflow over this network will be quite high). So how do I do this. I'm not a networking guy at all - I tried connecting them all, and nobody got an IP address (which I assume is because nobody is running a DNS server?). What all do I need to do to make this work? PS - two are running windows, one is running ubuntu.

    Read the article

  • WPF TreeViewItem Context Menu Unhighlights Item

    - by Snea
    I have been having problems with this for some time now, and have come up with some less-than-desirable solutions. The problem is that when a TreeViewItem's context menu is opened, the TreeViewItem is greyed out. Is it possible for a TreeViewItem to stay highlighted while its ContextMenu is open? The problem with the TreeViewItem greying out, is that it gives no relation to the context menu and the TreeViewItem, and it looks ugly. Generally, the code I use for setting a context menu is this. Sometimes the context menu will be generated by the code with a PreviewRightMouseButtonDown EventSetter, but it doesn't make a difference. <TreeView> <TreeView.Resources> <Style TargetType="{x:Type TreeViewItem}"> <Setter Property="ContextMenu"> <Setter.Value> <ContextMenu> <MenuItem Header="Menu Item 1" /> <MenuItem Header="Menu Item 2" /> </ContextMenu> </Setter.Value> </Setter> </Style> </TreeView.Resources> <TreeViewItem Header="Item 1"> <TreeViewItem Header="Sub-Item 1"/> </TreeViewItem> <TreeViewItem Header="Item 2"></TreeViewItem> </TreeView> So far the only solution I have found is to override the "grey" unfocused color with the focused color, but then the TreeView never seems unfocused, such as when another control is clicked on. I have had problems with ListViews as well.

    Read the article

  • How to pass a Context when using acts_as_taggable_on for assigning tags

    - by kbjerring
    I am using acts_as_taggable_on for assigning 'fixed' categories as well as free' tags to a Company model. My question is how I can pass the correct tag Context for the two different kinds of tags in the form view. For instance, I would like the user to click all the "sector" categories that apply to a company, and then be freely allowed to add additional tags. At this point, the only way I have gotten this to work is through the company model (inspired by this question): # models/company.rb class Company ... acts_as_taggable_on :sectors, :tags has_many :sector_tags, :through => :taggings, :source => :tag, has_many :taggings, :as => :taggable, :include => :tag, :class_name => "ActsAsTaggableOn::Tagging", :conditions => { :taggable_type => "Company", :context => "sectors" } ... end in the form (using the simple_form gem) I have... # views/companies/_form.html.haml = simple_form_for @company do |f| = f.input :name = f.association :sector_tags, :as => :check_boxes, :hint => "Please click all that apply" = f.input :tag_list But this obviously causes the two tag types ("sectors" and "tags") to be of the same "sectors" context which is not what I want. Can anyone hint at how I can pass the relevant Context ("sectors") in the form where the user assigns the sector tags? Or maybe I can pass it in the "has_many :sector_tags ..." line in the Company model? A related question is if this is a good way to do it at all? Would I be better off just using a Category model for assigning sector tags through a joint model? Thanks!

    Read the article

  • Issues Deploying ROOT Context in Tomcat6

    - by Josh K
    I'm working on getting an application deployed to the ROOT ("/") context in my Tomcat 6 instance. Here's what has been done: Defined another virtual host (domain.com) Created the respective folder (/etc/tomcat6/Catalina/domain.com) Set it to auto deploy WAR's Set appBase to CATALINA_BASE/domainapps and created respective folder Copied manager.xml from localhost to domain.com. Now I'm trying to deploy into the ROOT context by uploading a ROOT.war to CATALINA_BASE/domainapps. This isn't working. I don't get any exceptions thrown, but the stock ROOT page ("It works !") stays up. I have successfully deployed it into another context (by uploading domainapp.war and viewing at /domainapp), but not ROOT. Re-reading the Virtual Host setup it makes reference to CATALINA_HOME and CATALINA_BASE. My CATALINA_HOME is at /usr/share/tomcat6/domainapp while CATALINA_BASE is /var/lib/tomcat6. Which should I be using for what? Currently haven't touched CATALINA_HOME but will try messing with a few things there. A better question might be what is the generally accepted flow taken to setup a new Tomcat instance and deploy an application to the root context.

    Read the article

  • How to get mouseposition when context menu appears?

    - by ikky
    Hi. I have a panel which holds many pictureboxes. Each picturebox has registered "contextRightMenu" as their context menu. What i want when the context menu pops up is to get the current mouseposition. I have tried getting the mouseposition by using mouseDown and click, but these events happens after one of the items of the context menu is clicked, and that is too late. the popup event of the context menu does not deliver mouse event args, so i don't know how to get the mouseposition. If i can get mouse event args it is easy. Then i just can: this.contextRightClick.Popup += new System.EventHandler(this.contextRightClick_Popup); // If EventArgs include mouseposition within the sender private void contextRightClick_Popup)(object sender, EventArgs e) { int iLocationX = sender.Location.X; int iLocationY = sender.Location.Y; Point pPosition = new Point(iLocationX + e.X, iLocationY + e.Y); // Location + position within the sender = current mouseposition } Can anyone help me either get some mouse event args, or suggest a event that will run before the contextmenu pop ups? Thanks in advance

    Read the article

  • How to bind a servlet to a context?

    - by simpatico
    I got javax.servlet.ServletException: Error instantiating servlet class servlets.MemoServlet javax.naming.NameNotFoundException: Name servlets.MemoServlet is not bound in this Context when using <form action="MemoServlet"> I know I could use managedbeans, but I've to use servlets. I suspect the problem has to do with JSF. context.xml: <?xml version="1.0" encoding="UTF-8"?> <Context antiJARLocking="true" path="/MemoWeb/faces"/> web.xml: <servlet-mapping> <servlet-name>MemoServlet</servlet-name> <url-pattern>/faces/MemoServlet</url-pattern> </servlet-mapping> <servlet> <servlet-name>MemoServlet</servlet-name> <servlet-class>servlets.MemoServlet</servlet-class> </servlet> I seem to have this problem all over the place: com.sun.faces.mgbean.ManagedBeanCreationException: An error occurred performing resource injection on managed bean userManager .... Caused by: javax.naming.NameNotFoundException: Name user.UserManager is not bound in this Context

    Read the article

  • Context path routing in Tomcat ( service swapping )

    - by jojovilco
    Here is what I would like to achieve: I have a web service A which I want to be able to deploy side by side with other web services of type A - different version(s). For now I assume 2 instances side by side. I need it because the service has a warm up stage, which takes some time to build up stuff from DB and only after it is ready it can start serving requests ... I was thinking to deploy to Tomcat context paths like: "/ServiceA-1.0", "/ServiceA-2.0" and then have a "virtual" context like "/ServiceA" which will point to the desired physical service e.g. "/ServiceA-1.0". So external world will know about ServiceA, but internally, my ServiceA related stack would know about versioned ServiceA url ( there are more components involved but only ServiceA is serving outer world ). When new service is ready, I would just reconfigure the "virtual" context to point to a new service. So far, I was not able to find out how to do this with Tomcat and starting to tkink it is not possible. I found suggestions to place Apache Server in front of Tomcat and do the routing there, but I do not want to enroll another piece of software unless necessary. My questions are: - is this kind of a "virtual" context and routing possible to do with Tomcat? - any other options, wisdom and lessons learned how to achieve this kind of service swapping scenario? Best, Jozef

    Read the article

  • error: 'void Base::output()' is protected within this context

    - by Bill
    I'm confused about the errors generated by the following code. In Derived::doStuff, I can access Base::output directly by calling it. Why can't I create a pointer to output() in the same context that I can call output()? (I thought protected / private governed whether you could use a name in a specific context, but apparently that is incomplete?) Is my fix of writing callback(this, &Derived::output); instead of callback(this, Base::output) the correct solution? #include <iostream> using std::cout; using std::endl; template <typename T, typename U> void callback(T obj, U func) { ((obj)->*(func))(); } class Base { protected: void output() { cout << "Base::output" << endl; } }; class Derived : public Base { public: void doStuff() { // call it directly: output(); Base::output(); // create a pointer to it: // void (Base::*basePointer)() = &Base::output; // error: 'void Base::output()' is protected within this context void (Derived::*derivedPointer)() = &Derived::output; // call a function passing the pointer: // callback(this, &Base::output); // error: 'void Base::output()' is protected within this context callback(this, &Derived::output); } }; int main() { Derived d; d.doStuff(); }

    Read the article

  • Router and Switch VLAN Configuration for Isolated Network

    - by Ben
    I haven't worked with VLANs much in the past and I was hoping if I could get a good explanation of what I need to setup for this to work. I have a Netgear WNR2000v2 router and a Netgear GS108T smart switch currently in my network. The fourth port on the router connects to port one on the switch. I would like to be able to isolated port 8 on the switch for use as a "guest port" when I bring home malware infested PCs for repair. I figured the VLAN capabilities of the GS108T would be able to do this for me, but I think I have a misunderstanding of how the VLAN actually works. Port 8 needs internet access but should not be able to communicate with the rest of the PCs on the home network. The subnet for the home network is 192.168.1.0/24 and I would like the guest PC to have A) 192.168.1.64 or B) 192.168.2.2. I am reading a lot of stuff about port trunking and VLAN membership, but I am confused as to which setup needs to be in place to make this work. Any help is greatly appreciated! Let me know if there is more information I need to provide. Definitely looking to learn something from this project. Thanks!

    Read the article

  • Sonicwall NSA 240, Configured for LAN and DMZ, X0 and X2 on same switch - ping issues

    - by Klaptrap
    Our Sonicwall vendor supplied and networked the NSA240 when we required a DMZ in our infrastructure. This was configured and appeared correct although VPN users periodically dropped DNS and Terminal Services. The vendor could not resolve and so the call was escalated to Sonicwall. The Sonicwall support engineer took a look and concluded that the X0 (LAN) and X2 (DMZ) intefaces were cabled to the same switch and so this is the issue. What he observed is a ping request to the LAN Domain Controller, from a connected VPN user, is forwarded (x0) from the VPN client IP to the DC IP but the ping response from the DC IP to the VPN client IP is on X2, a copy of the log is detailed below:- 02/02/2011 10:47:49.272 X1*(hc) X0 192.168.1.245 192.168.1.8 IP ICMP -- FORWARDED 02/02/2011 10:47:49.272 -- X0* 192.168.1.245 192.168.1.8 IP ICMP -- FORWARDED 02/02/2011 10:47:49.272 X2*(i) -- 192.168.1.8 192.168.1.245 IP ICMP -- Received X0 - LAN X1 - WAN X2 - DMZ The Sonicwall engineer concluded that we either need a seperate switch for X2 or we use a VLAN switch for both. I am the companies software engineer and we have yet to have heard back from the vendor, so I am lost at sea at the moment. Do we need to buy this additional equipment or is there another configuration on the NSA240 we can use?

    Read the article

  • A switch and router between the printer and PC that want to print but cannot

    - by Robert Memo
    IP 192.168.1.5 has a wireless connection to a Linksys router (192.168.1.1) which then is connected to a switch. The switch is connected to a server (192.168.0.2). My printer has IP address of 192.168.0.8. Internet connection is fine on 192.168.1.5. Problem 1: IP 192.168.1.5 can not print using printer 192.168.0.8. Problem 2: IP 192.168.1.2 can not access a shared folder on the the server. The reason for connecting this way is that, the server does not release wireless signal. In order to get wireless signal the Router is connected to the switch. The server is a computer server that only has one outgoing LAN port. Plus, due to inconvinience physical locations, I do not have option to change the physical locations and the way it is connected already. I just want the labtops that only have wireless connection to communicate with the printer and the server. I have tried to change the router IP address to 192.168.0.x like the server and printer. It caused problem for the laptop. The router no longer release internet signals. The router does have IP address from the server 192.168.0.5.

    Read the article

  • xl2tpd[845]: parse_config: line 13: data 'ipsec sared=yes' occurs with no context

    - by mmc18
    When I executed xl2tpd I amhaving following error. # xl2tpd -D xl2tpd[845]: parse_config: line 13: data 'ipsec sared=yes' occurs with no context xl2tpd[845]: init: Unable to load config file When I remove the "line 13" I having same error with "Line 14" thefore I do not think that the problem is about "ipsec sared" Here is my configuration file xl2tpd.conf. LINUX Ubuntu 12.0.4 ;Openswan IPsec 2.6.37; xl2tpd version: xl2tpd-1.3.1 ; [global] ipsec sared=yes listen-addr=47.168.137.27 ; [lns default] ip range = 192.168.1.10-192.168.1.20 local ip = 192.168.1.1 require chap = yes refuse pap = yes require authentication = yes ppp debug = yes pppoptfile = /etc/ppp/options.xl2tpd length bit = yes name=LinuxIPSECVPN ANSWER:(since have not enough reputation I am writting it over here.) removing the ";" character at the beginning of [global] and [lns default] have solved the issue. At fist I tought that [global] and[lns default] were just a comment.

    Read the article

  • IOGEAR GCS632U KVM casues Windows 7 Screensaver to not work

    - by ahsteele
    When my Windows 7 laptop is in its dock and connected to the IOGEAR GCS632U KVM switch the screensaver will not start. If connected directly to the mouse and keyboard while in the dock the screensaver starts normally. The screensaver also works when out of the dock. I need the screensaver to work when connected to the KVM. What's causing the screensaver not to start? Suggestions on how to remedy the problem?

    Read the article

  • HP ProCurve Port Mode Configuration Question

    - by SvrGuy
    We have a ProCurve Switch 2810-48G (J9022A). We need to disable auto negotiation on two ports and manually configure them to be full duplex gige ports. From the web GUI, Configuration Tab, Port Configuration sub tab, I am only presented with the option to configure the port as Auto - 1000. I take this to mean, auto negotiate duplex, manually configure the speed to be gige. How do I manually configure the port such that it is manually configured to use full duplex, 1000 mbs?

    Read the article

  • Daisy-chaining network switches with multiple cables

    - by user72153
    This might just be the dumbest question you'll ever read, but I digress. Say I have two 100Mbps Ethernet switches with 2 computers on each, connected together by a single cable. This way, the two PCs on each switch share the 100Mbps bandwidth with the others. If I added another cable between the 2 switches, would there be 200Mbps throughput available between the switches? Or am I completely off my rocker? Thanks for the help.

    Read the article

  • Why does a wired network slow down with user increase?

    - by Ed Briscoe
    If you had a wired network, 20 PCs hooked up to a 100 Mbit/sec switch (same onboard ethernet port speed) and you were just sending some test data round. What is the technical explanation as to why 20 machines sending test data around this network to each other is slower than one to one? I mean I know a busy network means it's slower but I'm really trying to understand some more technical details. Thanks for any help

    Read the article

  • Spanning-tree setup with incompatible switches

    - by wfaulk
    I have a set of eight HP ProCurve 2910al-48G Ethernet switches at my datacenter that are set up in a star topology with no physical loops. I want to partially mesh the switches for redundancy and manage the loops with a spanning-tree protocol. However, our connection to the datacenter is provided by two uplinks, each to a Cisco 3750. The datacenter's switches are handling the redundant connection using PVST spanning-tree, which is a Cisco-proprietary spanning-tree implementation that my HP switches do not support. It appears that my switches are not participating in the datacenter's spanning-tree domain, but are blindly passing the BPDUs between the two switchports on my side, which enables the datacenter's switches to recognize the loop and put one of the uplinks into the Blocking state. This is somewhat supposition, but I can confirm that, while my switches say that both of the uplink ports are forwarding, only one is passing any real quantity of data. (I am assuming that I cannot get the datacenter to move away from PVST. I don't know that I'd want them to make that significant of a change anyway.) The datacenter has also sent me this output from their switches (which I have expurgated of any identifiable info): 3750G-1#sh spanning-tree vlan nnn VLAN0nnn Spanning tree enabled protocol ieee Root ID Priority 10 Address 00d0.0114.xxxx Cost 4 Port 5 (GigabitEthernet1/0/5) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32mmm (priority 32768 sys-id-ext nnn) Address 0018.73d3.yyyy Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Aging Time 300 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Gi1/0/5 Root FWD 4 128.5 P2p Gi1/0/6 Altn BLK 4 128.6 P2p Gi1/0/8 Altn BLK 4 128.8 P2p and: 3750G-2#sh spanning-tree vlan nnn VLAN0nnn Spanning tree enabled protocol ieee Root ID Priority 10 Address 00d0.0114.xxxx Cost 4 Port 6 (GigabitEthernet1/0/6) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32mmm (priority 32768 sys-id-ext nnn) Address 000f.f71e.zzzz Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Aging Time 300 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Gi1/0/1 Desg FWD 4 128.1 P2p Gi1/0/5 Altn BLK 4 128.5 P2p Gi1/0/6 Root FWD 4 128.6 P2p Gi1/0/8 Desg FWD 4 128.8 P2p The uplinks to my switches are on Gi1/0/8 on both of their switches. The uplink ports are configured with a single tagged VLAN. I am also using a number of other tagged VLANs in my switch infrastructure. And, to be clear, I am passing the tagged VLAN I'm receiving from the datacenter to other ports on other switches in my infrastructure. My question is: how do I configure my switches so that I can use a spanning tree protocol inside my switch infrastructure without breaking the datacenter's spanning tree that I cannot participate in?

    Read the article

  • Unable to create context rendering error when run OpenGL application

    - by Rodnower
    Hello, I try to run Mesa gears example and I get following error: freeglut (./gears): Unable to create direct context rendering for window 'Gears' This may hurt performance. though the application runs successfully, but I guess that in future I will have much problems with productivity. I run Linux CentOS 5 on WMvare 7. Mesa's version is 6.5 Relevant output of lspci -v gives: 00:0f.0 VGA compatible controller: VMware SVGA II Adapter (prog-if 00 [VGA controller]) Subsystem: VMware SVGA II Adapter Flags: bus master, medium devsel, latency 64, IRQ 9 I/O ports at 10d0 [size=16] Memory at d0000000 (32-bit, non-prefetchable) [size=128M] Memory at d8000000 (32-bit, non-prefetchable) [size=8M] [virtual] Expansion ROM at 30000000 [disabled] [size=32K] Capabilities: [40] Vendor Specific Information Any one have idea? There is driver of vmvare for CentOS? Thank you for ahead.

    Read the article