Search Results

Search found 11618 results on 465 pages for 'rescue mode'.

Page 26/465 | < Previous Page | 22 23 24 25 26 27 28 29 30 31 32 33  | Next Page >

  • OpenLDAP mirror mode replication failing with TLS behind a load balancer

    - by Lynn Owens
    I have two OpenLDAP servers that are both running TLS. They are: ldap1.mydomain.com ldap2.mydomain.com I also have a load balancer cluster with a dns name of it's own: ldap.mydomain.com The SSL certificate has a CN of ldap.mydomain.com, with SANs of ldap1.mydomain.com and ldap2.mydomain.com. Everything works... Except mirror mode replication. My mirror mode replication is setup like this: ldap.conf TLS_REQCERT allow cn=config.ldif olcServerID: 1 ldap://ldap1.mydomain.com olcServerID: 2 ldap://ldap2.mydomain.com On ldap1, olcDatabase{1}hdb.ldif olcMirrorMode: TRUE olcSyncrepl: {0}rid=001 provider=ldap://ldap2.mydomain.com bindmethod=simple bindmethod=simple binddn="cn=me,dc=mydomain,dc=com" credentials="REDACTED" starttls=yes searchbase="dc=mydomain,dc=com" schemachecking=on type=refreshAndPersist retry="60 +" On ldap2, olcDatabase{1}hdb.ldif olcMirrorMode: TRUE olcSyncrepl: {0}rid=001 provider=ldap://ldap1.mydomain.com bindmethod=simple bindmethod=simple binddn="cn=me,dc=mydomain,dc=com" credentials="REDACTED" starttls=yes searchbase="dc=mydomain,dc=com" schemachecking=on type=refreshAndPersist retry="60 +" Here's the errors I'm getting in syslog: Dec 1 21:05:01 ldap1 slapd[6800]: slap_client_connect: URI=ldap://ldap2.mydomain.com DN="cn=me,dc=mydomain,dc=com" ldap_sasl_bind_s failed (-1) Dec 1 21:05:01 ldap1 slapd[6800]: do_syncrepl: rid=001 rc -1 retrying Dec 1 21:05:08 ldap1 slapd[6800]: conn=1111 fd=20 ACCEPT from IP=ldap.mydomain.com:2295 (IP=ldap1.mydomain.com:636) Dec 1 21:05:08 ldap1 slapd[6800]: conn=1111 fd=20 closed (TLS negotiation failure) Any ideas? I've been working on OpenLdap for way too long now.

    Read the article

  • How to find cause of main file system going to read only mode

    - by user606521
    Ubuntu 12.04 File system goes to readonly mode frequently. First of all I have read this question file system is going into read only mode frequently already. But I have to know if it's not caused by something else than dying hard drive. This is server provided by my client and I am just runing there some node.js workers + one node.js server and I am using mongodb. From time to time (every 20-50h) system suddenly makes filesystem read only, mongodb process fails (due read-only fs) and my node workers/server (which are started by forever) are just killed. Here is the log from dmesg - I can see there some errors and messages that FS is going to read-only, and there is also some JOURNAL error but I would like to find cause of those errors.. http://speedy.sh/Ux2VV/dmesg.log.txt edit smartctl -t long /dev/sda smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.5.0-23-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net SMART support is: Unavailable - device lacks SMART capability. A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options. What I am doing wrong? Same is for sda2. Morover now when I type any command that not exists in shell I get this: Sorry, command-not-found has crashed! Please file a bug report at: https://bugs.launchpad.net/command-not-found/+filebug Please include the following information with the report:

    Read the article

  • Using 1920x1200 mode on SyncMaster T260HD in Linux

    - by dagorym
    I just got a Samsung SyncMaster T260HD monitor. It works straight out of the box with Windows but I can't seem to get it to work with Linux, which is my primary OS for day to day work. The computer boots up but when going into graphical mode on Linux the monitor gives me a "Mode not supported" error and doesn't display anything. I booted up windows and, using PowerStrip, grabbed the exact ModeLine that should be used to get the equivalent setting in Linux and added it to my xorg config file but it doesn't seem to help. the ModeLine is: ModeLine "1920x1200" 153.9 1920 1984 2016 2080 1200 1203 1209 1235 +hsync -vsync This is the modeline for the working display settings in windows but it doesn't seem to work in Linux My complete entry in the xorg.conf file for the monitor is Section "Monitor" Identifier "Monitor0" ModelName "SyncMaster" DisplaySize 518 324 HorizSync 30.0 - 81.0 VertRefresh 56.0 - 75.0 Option "dpms" ModeLine "1920x1200" 153.9 1920 1984 2016 2080 1200 1203 1209 1235 +hsync -vsync EndSection I'm running Scientific Linux 5.4 (clone of Redhat Enterprise Linux 5.4) but I've tried booting with a recent Linux Mint Distro as well as Ubuntu 9.04 and had the same problem. Any suggestions on other things I should try or might be missing? If anyone's gotten this to work I'd love to know. Thanks.

    Read the article

  • How can I debug user mode driver failures in Windows 8

    - by Tom
    I have a 32 GB SD Card. Whenever I insert this card in to my newly upgraded Windows 8 laptop the OS stops responding normally. Metro Apps won't work. The system may or may not log in. Desktop apps may or may not be able to do things. When I remove the card and restart then all is fine. As soon as I put the card back in, the system starts misbehaving again. I've run Windows Update, so I have the latest drivers from Microsoft. This does not occur with the 8 GB cards I have. Unfortunately I only have one 32 GB card, so I can't test with others. From examining the system event log I've determined this is happening due to a user mode driver failure. How can I best debug this issue from here? How can I figure out which driver this is related to? Will there be a Dr. Watson crash dump somewhere? Details - System - Provider [ Name] Microsoft-Windows-DriverFrameworks-UserMode [ Guid] {2E35AAEB-857F-4BEB-A418-2E6C0E54D988} EventID 10110 Version 1 Level 1 Task 64 Opcode 0 Keywords 0x2000000000000000 - TimeCreated [ SystemTime] 2012-10-29T00:51:57.532718300Z EventRecordID 40417 Correlation - Execution [ ProcessID] 1056 [ ThreadID] 3796 Channel System Computer thebrain - Security [ UserID] S-1-5-18 - UserData - UMDFHostProblem [ lifetime] {811E3DC4-FBC6-420B-ABCC-AD7505A36F3B} - Problem [ code] 3 [ detectedBy] 2 ExitCode 3 - Operation [ code] 259 Message 72448 Status 4294967295 Edit 1 So I tried using Debug View from SysInternals (you can get it here: http://technet.microsoft.com/en-us/sysinternals/bb896647.aspx). That gave me this information: which is not especially helpful. Then I tried connecting WinDbg to WUDFHost.exe (the process that seems to host user mode drivers) to see if it could catch the error. Get it here: http://msdn.microsoft.com/en-US/windows/hardware/hh852363 Instructions: http://msdn.microsoft.com/en-US/library/windows/hardware/ff554716(v=vs.85).aspx That didn't help much. It didn't catch any exceptions as I'd hoped (which would point me to the cause of the crash at least). Here's the stack of one of the threads:

    Read the article

  • How do I repair a Windows 7 installation damaged by Windows 8 sleep mode

    - by Mat
    I'm experimenting with a Windows 8 installation which is on a separate SSD. My actual Windows 7 installation I'm working with is on my old HDD. While Windows 8 was in sleep mode I swapped the hard disks and put in the Windows 7 HDD (I thought the computer was off). When I started the computer, Windows 8 started back up to the login screen – then it was stuck and some seconds later the computer rebooted. Now the Windows 7 Installation is damaged. When I boot, after the Windows 7 startup logo appears, a bluescreen shows up for few seconds stating: STOP: c000021a {Fatal System Error} The verification of KnownDLL failed. System process terminated unexpectedly with a status of 0xc000012f (0x00f0bb90 0x00000000). The system has been shut down. and then the computer reboots. The same happens in safe mode. 'Windows startup repair' cannot repair the issue. Any idea what could have happened exactly and/or how to repair this Windows 7 Installation?

    Read the article

  • Setting "Run WWW service in IIS 5.0 isolation mode" does not persist in IIS 6

    - by Saul Dolgin
    Our IIS server was recently patched with the latest Microsoft Security Updates and since then, I am unable to enable the "Run WWW service in IIS 5.0 isolation mode" setting. This setting was enabled prior to patching and somehow changed during the updates. I have tried both using the IIS Manager console and the adsutil.vbs approach to change it. Either way, after resetting IIS for the change to take effect, when I go to verify that the isolation mode setting is enabled (true) I find that is reverts back to being disabled (false). Now... The patches have already been rolled back, however the setting still does not persist when I enable it. While I am trying to research the patches that were applied to see if there is a known issue (or perhaps a change in this setting's behavior) I was hoping someone else might have come across the same problem. Any help towards a workaround would be greatly appreciated! >cscript adsutil.vbs set W3SVC/IIs5IsolationModeEnabled TRUE IIs5IsolationModeEnabled : (BOOLEAN) True >iisreset Attempting stop... Internet services successfully stopped Attempting start... Internet services successfully restarted >cscript adsutil.vbs get W3SVC/IIs5IsolationModeEnabled IIs5IsolationModeEnabled : (BOOLEAN) False

    Read the article

  • Windows Vista - Can Boot into Safe Mode Command Prompt, Cannot Access Flash Drive

    - by Adam
    Hey there, Got a laptop dropped into my lap. Has Vista installed. Normal boot never gets past the login screen. Safe mode will get past, but just barely. I can try and start the task manager at that point, but it never opens. Only reliable way to do anything I've got is the safe mode command prompt... Boots up and logs in fine. I can't see anything noticably wrong via regedit, but it's been a long time since I've had to fix up a Windows box... not sure that I would. Problem I'm having, is that I want to run ComboFix/etc, but have no way to get them on there... When I pop a flash drive in, it seems to mount it (flash drive flickers as normal) but it never seems to be mounted... I cannot access it through any drive letter on the command line. I managed to start the device manager (devmgmt.msc) and the flash drive was recognized and listed... Any ideas on how to get this thing going again? (Short of a reinstall.) (It has no CD drive, either, so burning files to CD would not be easy...) Thanks! Adam

    Read the article

  • Windows XP only loads in VGA mode, and crashes when raising resolution

    - by Harel
    My kid's computer (Windows XP, SP3) started to (what appears to be) crash on boot. It will only boot in Safe or VGA mode, and if I try to raise the resolution from 640x480 it just reboots itself, and a error appears in the Event Log. When it loads up not in VGA mode, the monitor shuts off just after the windows logo is shown. It seems like windows is actually running but I can't see anything on screen (monitor is off for lack of signal). Nothing was installed recently that I know of, short of the usual windows updates. Thanks, Harel Below is the event log error: Event Type: Error Event Source: System Error Event Category: (102) Event ID: 1003 Date: 15/04/2012 Time: 16:27:11 User: N/A Computer: ----- Description: Error code 1000008e, parameter1 c0000005, parameter2 f745b0bf, parameter3 ede24f98, parameter4 00000000. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 53 79 73 74 65 6d 20 45 System E 0008: 72 72 6f 72 20 20 45 72 rror Er 0010: 72 6f 72 20 63 6f 64 65 ror code 0018: 20 31 30 30 30 30 30 38 1000008 0020: 65 20 20 50 61 72 61 6d e Param 0028: 65 74 65 72 73 20 63 30 eters c0 0030: 30 30 30 30 30 35 2c 20 000005, 0038: 66 37 34 35 62 30 62 66 f745b0bf 0040: 2c 20 65 64 65 32 34 66 , ede24f 0048: 39 38 2c 20 30 30 30 30 98, 0000 0050: 30 30 30 30 0000

    Read the article

  • How to use WPA2 client mode in the Linux-based Cisco WAP4410N access point

    - by joechip
    I have a Cisco WAP4410N access point that I want to use as a client to connect to a WPA2 wireless network (for WLAN service monitoring purposes). Supposedly this access point supports a "Wireless Client/Repeater" mode that allows to do this. The Repeater function is optional (I have that box unchecked so that nobody can connect to this access point wirelessly). I have verified through SSH that the access point gets configured as a client and not as a Master. But it never associates to the SSID I ask it to. This is what iwconfig shows: ath04 IEEE 802.11ng ESSID:"myownssid" Mode:Managed Channel:0 Access Point: Not-Associated Bit Rate:0 kb/s Tx-Power:14 dBm Sensitivity=1/3 Retry:off RTS thr:off Fragment thr:off Encryption key:off Power Management:off Link Quality=0/94 Signal level=161/162 Noise level=161/161 Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:0 Invalid misc:0 Missed beacon:0 Although I've never done this from the command line, I suppose I could use wpa_supplicant or wpa_client to associate it, but I don't know how to do that without editing configuration files and the filesystem is readonly. Besides, I would have to run those commands manually after every reboot. I'd like to know how to do this the Cisco way, if possible. If not, any trick to make this work would be useful. Edit: This is with the latest firmware, 2.0.4.2. And I found that not all of the filesystem is readonly, since /var and /tmp are mounted with type ramfs.

    Read the article

  • SSH Interactive mode not working

    - by Ekin Koc
    I have a Debian based linux server running for a year or so, without any problems. A couple of days ago, ssh interactive mode stopped working for no reason. I mean, I can open an ssh connection just fine, the server greets me with shell but I just can't type anything. However, if I send commands like this: ssh [email protected] cat /var/log/messages, I get the response. I dug through several logs and found one message, which feels remotely relevant to the problem; sh kernel: [10222733.062511] ------------[ cut here ]------------ sh kernel: [10222733.062522] WARNING: at /build/buildd-linux-2.6_2.6.32-39-amd64-7yVIH2/linux-2.6-2.6.32/debian/build/source_amd64_none/drivers/char/tty_ldisc.c:738 tty_ldisc_reinit+0x46/0x7b() sh kernel: [10222733.062526] Hardware name: PowerEdge R210 II sh kernel: [10222733.062528] Modules linked in: ipt_MASQUERADE iptable_nat nf_nat nf_conntrack_ipv4 nf_conntrack nf_defrag_ipv4 ip_tables x_tables sha1_generic arc4 ecb ppp_mppe ppp_async crc_ccitt ppp_generic slhc loop snd_pcm snd_timer snd soundcore snd_page_alloc i2c_i801 i2c_core pcspkr evdev joydev dcdbas container button processor ext3 jbd mbcache sg sd_mod sr_mod crc_t10dif cdrom usb_storage usbhid hid mpt2sas ahci ehci_hcd libata scsi_transport_sas usbcore bnx2 nls_base scsi_mod fan thermal thermal_sys [last unloaded: scsi_wait_scan] sh kernel: [10222733.062568] Pid: 8662, comm: sshd Not tainted 2.6.32-5-amd64 #1 sh kernel: [10222733.062569] Call Trace: sh kernel: [10222733.062572] [<ffffffff811ff056>] ? tty_ldisc_reinit+0x46/0x7b sh kernel: [10222733.062574] [<ffffffff811ff056>] ? tty_ldisc_reinit+0x46/0x7b Is there any way to get back the sshd working in interactive mode? I tried restarting sshd but that is no help. And somehow, I can not reboot the server. Tried sending shutdown -r now and reboot but it refuses to go down. Should I go ahead and request a physical reboot?

    Read the article

  • Computer Won't Boot Properly, unless in safe mode?

    - by Mr_CryptoPrime
    I bought a computer today and booted it up, but when I did I only got a blank screen. I checked to make sure it wasn't the monitor by connecting it to my old computer...it worked. I then tried connecting my monitor to both DVI ports and found that the bottom one did work. However, now it just boots up and says "loading windows" and then when the login screen is suppose to come up the screen just goes blank and monitor says "no input, check cord" (or something like that). I tried reinstalling windows and then I was able to log on normally. I used the CD's and reinstalled all the drivers, then rebooted...now I am stuck right back where I started. I tried taking out the RAM and inserting into different slots, that didn't fix anything. I was able to boot up into windows using safe-mode. I suspected that my ATI Radeon 6950 was the issue and downloaded the drivers, but I can't install them on safe-mode. Someone said to install C++ distr. and I tried doing that to fix driver installation problem of "failed to load detection driver" but it wouldn't let me do that either. Please someone help me, I don't want to have to deal with the evil redtape of sending it back to get a replacement! My computer: -Content--text-_-"http://www.newegg.com/Product/Product.aspx?Item=N82E16883229236&nm_mc=TEMC-RMA-Approvel&cm_mmc=TEMC-RMA-Approvel--Content--text-_- Driver detection problem: http://www.hardwareheaven.com/hardwareheaven-tools-discussion/174912-failed-load-detection-driver-installation-error.html Driver download page: http://sites.amd.com/us/game/downloads/Pages/radeon_win7-64.aspx#1 I am using windows 7. Thanks again.

    Read the article

  • Computer Won't Boot Properly, unless in safe mode?

    - by Mr_CryptoPrime
    I bought a computer today and booted it up, but when I did I only got a blank screen. I checked to make sure it wasn't the monitor by connecting it to my old computer...it worked. I then tried connecting my monitor to both DVI ports and found that the bottom one did work. However, now it just boots up and says "loading windows" and then when the login screen is suppose to come up the screen just goes blank and monitor says "no input, check cord" (or something like that). I tried reinstalling windows and then I was able to log on normally. I used the CD's and reinstalled all the drivers, then rebooted...now I am stuck right back where I started. I tried taking out the RAM and inserting into different slots, that didn't fix anything. I was able to boot up into windows using safe-mode. I suspected that my ATI Radeon 6950 was the issue and downloaded the drivers, but I can't install them on safe-mode. Someone said to install C++ distr. and I tried doing that to fix driver installation problem of "failed to load detection driver" but it wouldn't let me do that either. Please someone help me, I don't want to have to deal with the evil redtape of sending it back to get a replacement! My computer: -Content--text-_-"http://www.newegg.com/Product/Product.aspx?Item=N82E16883229236&nm_mc=TEMC-RMA-Approvel&cm_mmc=TEMC-RMA-Approvel--Content--text-_- Driver detection problem: http://www.hardwareheaven.com/hardwareheaven-tools-discussion/174912-failed-load-detection-driver-installation-error.html Driver download page: http://sites.amd.com/us/game/downloads/Pages/radeon_win7-64.aspx#1 I am using windows 7. Thanks again.

    Read the article

  • Windows takes a very long time to shut down even in safe mode

    - by user1526247
    On Windows 7 the computer freezes for about 5 minutes once it gets to "Shutting down...". I can't remember when it started happening. I just lived with it for a while. The first thing I tried was a full scan using Microsoft Security Essentials. This did not solve the problem. I then went into msconfig and turned off everything I could get away with in the startup and services tabs. This did not solve the problem. I then uninstalled every program on this computer save the most basic programs. This did not solve the problem (did not uninstall drivers or catalyst). I then went through and turned off every single service and did a reboot. This did not solve the problem. I then booted into safe mode and just tried shutting it down. The problem even happens in safe mode. I have tried examining the event logs but with no success. They just say things like "blah blah has entered the stopped state" with no real clues about what program is causing me all this grief. *it may be worth noting that Ubuntu is installed on the same computer and the ubuntu boot loader is the one being used.

    Read the article

  • Ubuntu boots in read-only filesystem after upgrade!

    - by akatzbreaker
    I got a serious problem here: I recently upgraded to the Latest Version of Ubuntu. Now, I boot to my Ubuntu Partition, and I get a Low-Graphics error! I boot to a Recovery-Mode to see what the Problem is. Then, I try to Fix any Damaged Packages, to run fsck but nothing solved the Problem. Then, from the Recovery Menu, I open a Root Shell. I try to create a File and I understand that the Filesystem is Read-Only. Then, I run: mount -o remount,rw / and it Worked for that Terminal Session! When I go back to recovery, I select to resume Boot Normally but I get the Same Error! a I also tried to Boot to my Root Shell again, remount as Read-Write and Start Gnome from there. It Worked! (But the user is ROOT, and is quite Dangerous!) However, I can't do all this proccess at every boot! Any Solution? (Note that when I try to create a new File in my Ubuntu Partition from another OS, I don't get any Errors!)

    Read the article

  • Does rails do a rollback if I use begin...rescue?

    - by codeman73
    I'd like to add a begin...rescue block to one of my controllers create method, in order to log better info and construct the correct error message to return to the client. Does the rescue in any way 'interrupt' the rollback process? I'm assuming rails automatically does a rollback. When does it happen? Has it already happened by the time I get in the rescue clause? I'm using mySQL on Dreamhost and I think they use innoDB.

    Read the article

  • DataGridView live display of datatable using virtual mode

    - by Chris
    I have a DataGridView that will display records (log entries) from a database. The amount of records that can exist at a time is very large. I would like to use the virtual mode feature of the DataGridView to display a page of data, and to minimize the amount of data that has to be transferred across a network at a given time. Polling for data is out of the question. There will be several clients running at a time, all of which are on the same network and viewing the records. If they all poll for data, the network will run very slowly. The data is read-only to the user; they won't be able to edit any of it, just view it. I need to know when updates occur in the database, and I need to update the screen with those updates accordingly using virtual mode. If a page of data a user is viewing contains data that has change, he/she will see those updates on that page. If updates were made to data in the database, but not in the data the user is viewing, then not much really changes on the user screen (Maybe just the scroll bar if records were added or removed). My current approach is using SQL server change tracking with the sync framework. Each client has a local SQL Server CE instance and database file that is kept in sync with the main database server. I use the information from the synchronization event to see if any changes were made to the main database and were sync'ed to the client. I need to use the DataGridView virtual mode here because I can't have thousands of records loaded into the DataGridView at once, otherwise memory usage goes through the roof. The main challenge right now is knowing how to use virtual mode to provide a seamless experience to the user by allowing them to scroll up and down through the records, and also have records update on the fly without interfering with the user inappropriately. Has anybody dealt with this issue before, and if so, where I can see how they did it? I've gone through some of the MSDN documentation and examples on virtual mode. So far, I haven't found documentation and/or examples on their site that explains how to do what I am trying to accomplish.

    Read the article

  • How do I rescue from a `require': no such file to load in ruby?

    - by René Nyffenegger
    I am trying to rescue from a `require': no such file to load in ruby in order to hint the user at specifying the -I flag in case he has forgotten to do so. Basically the code looks like: begin require 'someFile.rb' rescue puts "someFile.rb was not found, have you" puts "forgotten to specify the -I flag?" exit end I have expected the rescue part to take over execution in case someFile.rb was not found, but my assumption was wrong.

    Read the article

  • Monitor Mode on the Intel Centrino(R) Advanced-N 6205 (WEP Penetration) On Windows

    - by WindowsEscapist
    Can anyone tell me a way to do WEP hacking (legal, of course) (on my own wireless connection, for the purposes of this question) with Wireshark or similar programs on an Intel Centrino Advanced-N 6205? (Laptop is Acer Aspire 5750-6866.) According to the programs, I cannot accomplish this (monitor mode) but seeing as it is a fairly recent wireless card (should be able to support this) are there any cracked drivers available or does anyone have the knowledge to make one? Much appreciated! Thanks.

    Read the article

  • Task Sequence boots to logon screen instead of task sequence mode

    - by Ben M.
    I'm running a task sequence, and so that users don't accidentally interfere, I have the task sequence reboot to currently installed operating system, which as I understand, is supposed to boot to a sort of single user mode and all that shows is task sequence progress. However, this does not happen, it boots up like normal and comes to the logon screen and the task sequence runs in background. How can I adjust this behavior to the desired result?

    Read the article

  • changing ext4 journal data mode with remount?

    - by Amos Shapira
    I'm tweaking ext4 file system for speed, one tweak at a time. First tweak is to change from "data=ordered" to "data=writeback". To test this, I execute "mount -n -o remount,data=ordered /" but I keep getting "mount: / not mounted already, or bad option". From lots of google'ing I found many questions about similar problems and one answer circa 2001+ext3 which says that you can't change the journal mode with remount. Is this limitation still current?

    Read the article

  • running csync2 in stand-alone server mode gives error

    - by amin
    I installed csync2 on two ubuntu node as documentation in http://oss.linbit.com/csync2/paper.pdf. when i use a one-shot command csync2 -xv every thing goes well. but when i try to run csync2 in stand-alone server mode i get error: Server error: Address already in use. i searched over net and no documentation found on this problem, even tracing code and grep in files didn't get any result of problem source. do you have any idea?

    Read the article

  • Combining two operators in Evil-mode Emacs

    - by Dyslexic Tangent
    In vim I've remapped > and < when in visual mode to >gv and <gv respectively, like so: vnoremap > >gv vnoremap < <gv Since my target for this question are folks experienced with emacs and not vim, what > and < do is indent/dedent visually selected text. What gv does is reselect the previously selected text. These maps cause > and < to indent/dedent and then reselect the previously selected text. I'm trying out emacs with evil-mode and I'd like to do the same, but I'm having some difficulty figuring out how, exactly, to accomplish the automatic reselection. It looks like I need to somehow call evil-shift-right and evil-visual-restore sequentially, but I don't know how to create a map that will do both, so I tried creating my own function which would call both sequentially and map that instead, but it didn't work, possibly due to the fact that both of them are defined, not as functions with defun but instead as operators with evil-define-operator. I tried creating my own operators: (evil-define-operator shift-left-reselect (beg end) (evil-shift-left beg end) (evil-visual-restore)) (evil-define-operator shift-right-reselect (beg end) (evil-shift-right beg end) (evil-visual-restore)) but that doesn't restore visual as expected. A stab in the dark gave me this: (evil-define-operator shift-left-reselect (beg end) (evil-shift-left beg end) ('evil-visual-restore)) (evil-define-operator shift-right-reselect (beg end) (evil-shift-right beg end) ('evil-visual-restore)) but that selects one additional line whenever it is supposed to reselect. For now I've been using the following, which only has the problem where it reselects an additional line in the < operator. (evil-define-operator shift-right-reselect (beg end) (evil-shift-right beg end) (evil-visual-make-selection beg end)) (evil-define-operator shift-left-reselect (beg end) (evil-shift-left beg end) (evil-visual-make-selection beg end)) and I've mapped them: (define-key evil-visual-state-map ">" 'shift-right-reselect) (define-key evil-visual-state-map "<" 'shift-left-reselect) any help / pointers / tips would be greatly appreciated. Thanks in advance.

    Read the article

  • Matching digits in Notepad++ extended search mode

    - by ketchup
    Notepad++'s manual is rather vague on the special character for numerical used in extended search mode. It says: \d### - Decimal value (between 000 and 255) but literally entering "\d###" doesn't match anything. What I am trying to do is to replace if VarA == 12 VarB = 1 with if VarA == 12 Var12=1 VarB=1

    Read the article

< Previous Page | 22 23 24 25 26 27 28 29 30 31 32 33  | Next Page >