  • Storage Configuration

    - by jchang
    Storage performance is not inherently complicated subject. The concepts are relatively simple. In fact, scaling storage performance is far easier compared with the difficulties encounters in scaling processor performance in NUMA systems. Storage performance is achieved by properly distributing IO over: 1) multiple independent PCI-E ports (system memory and IO bandwith is key) 2) multiple RAID controllers or host bus adapters (HBAs) 3) multiple storage IO channels (SAS or FC, complete path) most importantly,...(read more)

    Read the article

  • Working with Sub-Optimal Disk Configurations (Making the best of what you’ve got)

    - by Jonathan Kehayias
    This is the first post in a what will be a series of posts on working with a sub-optimal disk configuration to squeeze as much performance out of it as possible.  You might ask what a Sub-Optimal Disk Configuration?  In this case it is a Dell Powervault MD3000 with 15 Seagate Barracuda ES.2 SAS 1 TB 7.2K RPM disks (Model Number ST31000640SS).  This equates to just under 14TB of raw storage that can configured into a number of RAID configurations.  In this case, the disk array...(read more)

    Read the article

  • Cost Comparison Hard Disk Drive to Solid State Drive on Price per Gigabyte - dispelling a myth!

    - by tonyrogerson
    It is often said that Hard Disk Drive storage is significantly cheaper per GiByte than Solid State Devices – this is wholly inaccurate within the database space. People need to look at the cost of the complete solution and not just a single component part in isolation to what is really required to meet the business requirement. Buying a single Hitachi Ultrastar 600GB 3.5” SAS 15Krpm hard disk drive will cost approximately £239.60 (http://scan.co.uk, 22nd March 2012) compared to an OCZ 600GB Z-Drive R4 CM84 PCIe costing £2,316.54 (http://scan.co.uk, 22nd March 2012); I’ve not included FusionIO ioDrive because there is no public pricing available for it – something I never understand and personally when companies do this I immediately think what are they hiding, luckily in FusionIO’s case the product is proven though is expensive compared to OCZ enterprise offerings. On the face of it the single 15Krpm hard disk has a price per GB of £0.39, the SSD £3.86; this is what you will see in the press and this is what sales people will use in comparing the two technologies – do not be fooled by this bullshit people! What is the requirement? The requirement is the database will have a static size of 400GB kept static through archiving so growth and trim will balance the database size, the client requires resilience, there will be several hundred call centre staff querying the database where queries will read a small amount of data but there will be no hot spot in the data so the randomness will come across the entire 400GB of the database, estimates predict that the IOps required will be approximately 4,000IOps at peak times, because it’s a call centre system the IO latency is important and must remain below 5ms per IO. The balance between read and write is 70% read, 30% write. The requirement is now defined and we have three of the most important pieces of the puzzle – space required, estimated IOps and maximum latency per IO. Something to consider with regard SQL Server; write activity requires synchronous IO to the storage media specifically the transaction log; that means the write thread will wait until the IO is completed and hardened off until the thread can continue execution, the requirement has stated that 30% of the system activity will be write so we can expect a high amount of synchronous activity. The hardware solution needs to be defined; two possible solutions: hard disk or solid state based; the real question now is how many hard disks are required to achieve the IO throughput, the latency and resilience, ditto for the solid state. Hard Drive solution On a test on an HP DL380, P410i controller using IOMeter against a single 15Krpm 146GB SAS drive, the throughput given on a transfer size of 8KiB against a 40GiB file on a freshly formatted disk where the partition is the only partition on the disk thus the 40GiB file is on the outer edge of the drive so more sectors can be read before head movement is required: For 100% sequential IO at a queue depth of 16 with 8 worker threads 43,537 IOps at an average latency of 2.93ms (340 MiB/s), for 100% random IO at the same queue depth and worker threads 3,733 IOps at an average latency of 34.06ms (34 MiB/s). The same test was done on the same disk but the test file was 130GiB: For 100% sequential IO at a queue depth of 16 with 8 worker threads 43,537 IOps at an average latency of 2.93ms (340 MiB/s), for 100% random IO at the same queue depth and worker threads 528 IOps at an average latency of 217.49ms (4 MiB/s). From the result it is clear random performance gets worse as the disk fills up – I’m currently writing an article on short stroking which will cover this in detail. Given the work load is random in nature looking at the random performance of the single drive when only 40 GiB of the 146 GB is used gives near the IOps required but the latency is way out. Luckily I have tested 6 x 15Krpm 146GB SAS 15Krpm drives in a RAID 0 using the same test methodology, for the same test above on a 130 GiB for each drive added the performance boost is near linear, for each drive added throughput goes up by 5 MiB/sec, IOps by 700 IOps and latency reducing nearly 50% per drive added (172 ms, 94 ms, 65 ms, 47 ms, 37 ms, 30 ms). This is because the same 130GiB is spread out more as you add drives 130 / 1, 130 / 2, 130 / 3 etc. so implicit short stroking is occurring because there is less file on each drive so less head movement required. The best latency is still 30 ms but we have the IOps required now, but that’s on a 130GiB file and not the 400GiB we need. Some reality check here: a) the drive randomness is more likely to be 50/50 and not a full 100% but the above has highlighted the effect randomness has on the drive and the more a drive fills with data the worse the effect. For argument sake let us assume that for the given workload we need 8 disks to do the job, for resilience reasons we will need 16 because we need to RAID 1+0 them in order to get the throughput and the resilience, RAID 5 would degrade performance. Cost for hard drives: 16 x £239.60 = £3,833.60 For the hard drives we will need disk controllers and a separate external disk array because the likelihood is that the server itself won’t take the drives, a quick spec off DELL for a PowerVault MD1220 which gives the dual pathing with 16 disks 146GB 15Krpm 2.5” disks is priced at £7,438.00, note its probably more once we had two controller cards to sit in the server in, racking etc. Minimum cost taking the DELL quote as an example is therefore: {Cost of Hardware} / {Storage Required} £7,438.60 / 400 = £18.595 per GB £18.59 per GiB is a far cry from the £0.39 we had been told by the salesman and the myth. Yes, the storage array is composed of 16 x 146 disks in RAID 10 (therefore 8 usable) giving an effective usable storage availability of 1168GB but the actual storage requirement is only 400 and the extra disks have had to be purchased to get the  IOps up. Solid State Drive solution A single card significantly exceeds the IOps and latency required, for resilience two will be required. ( £2,316.54 * 2 ) / 400 = £11.58 per GB With the SSD solution only two PCIe sockets are required, no external disk units, no additional controllers, no redundant controllers etc. Conclusion I hope by showing you an example that the myth that hard disk drives are cheaper per GiB than Solid State has now been dispelled - £11.58 per GB for SSD compared to £18.59 for Hard Disk. I’ve not even touched on the running costs, compare the costs of running 18 hard disks, that’s a lot of heat and power compared to two PCIe cards!Just a quick note: I've left a fair amount of information out due to this being a blog! If in doubt, email me :)I'll also deal with the myth that SSD's wear out at a later date as well - that's just way over done still, yes, 5 years ago, but now - no.

    Read the article

  • Looking to trade a 1U HP Proliant DL360 G5 in exchange for a small linux VPS

    - by user597875
    I have a 1U HP Proliant DL360 G5 that I have no place to rack and would like to trade it for a small linux VPS. If interested let me know... Here are the specs of the server: Model: Intel Xeon CPU 5150 @ 2.66GHz, 4MB L2 Cache Processor Speed: 2.7GHz Processor Sockets: 2 Processor Cores per Socket: 2 Logical Processors: 4 8GB of memory 4x72GB 10k SAS drives Manufacturer: HP Model: Proliant DL360 G5 BIOS Version: P58

    Read the article

  • Analyzing I/O performance in Linux

    <b>cmdln.org:</b> "Monitoring and analyzing performance is an important task for any sysadmin. Disk I/O bottlenecks can bring applications to a crawl. What is an IOP? Should I use SATA, SAS, or FC? How many spindles do I need?"

    Read the article

  • How to disable the RAID in x3400 M2

    - by BanKtsu
    Hi I just wanna disable the default RAID in my server IBM System X3400 M2 Server(7837-24X),i have 3 disk drives SAS. I want to make them a JBOD "Just a Bunch Of Disks", because I want to install in the drive 0 CentOS, and the other two make them cache files for a squid server. I disable the RAID in the BIOS: System Settings/Adapters and UEFI drivers/LSI Logic Fusion MPT SAS Driver -PciRoot(0x0)/Pci(0x3,0X0)/Pci(0x0,0x0) LSI Logic MPT Setup Utility RAID Properties/Delete Array Later I boot the CentOS live CD and install the OS in the drive 0, and the others 2 mounted like this: *LVM Volume Groups vg_proxyserver 139508 lv_root 51200 / ext4 lv_home 84276 /home ext4 lv_swap 4032 Hard Drive sdb(/dev/sdb) free 140011 sdc(/dev/sdc) free 140011 sdd(/dev/sdd) sdd1 500 /boot ext4 sdd2 139512 vg_proxyserver physical volume(LVM) But when I restart the server give me the error: Boot failed Hard Disk 0 UEFI PXE PciRoot(0x0)/Pci(0x1,0X0)/Pci(0x0,0x0)/MAC(001A64B15130,0X0)) ........PXE-E18:Server response timeout. UEFI PXE PciRoot(0x0)/Pci(0x1,0X0)/Pci(0x0,0x0)/MAC(001A64B15132,0X0)) ........PXE-E18:Server response timeout. and the OS not start. The IBM force me to do a RAID?,why?

    Read the article

  • blu-ray archiving in vmware ESXi 4

    - by spacecadet77
    Hi, I need some advice about using blu-ray writer for archiving data on vmware ESXi 4. At office we have IBM System x3400 Tower server with ESXi 4 hipervisor and OpenSuse and CentOS GNU/Linux system as guests. Will blu-ray writer work in this setup, and if it will is there any particular model you can suggest. Best regards IBM System x3400 Tower server specification: 1x Intel Quad-Core Xeon E5410 2.33GHz/ 12MB/ 1333MHz (2x CPU max) Intel 5000P chipset, 2x 1GB PC2-5300 DDR2 667MHz SDRAM ECC Chipkill (32GB max) 2x4GB (2x2GB) PC2-5300 CL5 ECC DDR2 FBDIMM (x3400, x3550, x3650) SAS/SATA Hot-Swap Open Bay (0xHDD std, 4xHDD max, 8xHDD optional) ServeRAID 8K dual channel SAS/SATA controller (RAID 0,1,1E,10,5,6, 256MB, Battery Backup) Graphics ATI® RN50(ES1000) 16MB DDR, CD-RW/DVD Combo no FDD GigaEthernet, Tower with Power Supply 835W (opt Redudant) Slot 1: half-length, PCI-Express x8(x4 electrical) Slot 2: full, PCI-Express x8 Slot 3: full, PCI-Express x8 Slot 4: full, 64-bit 133MHz 3.3v PCI-X Slot 5: full, 64-bit 133MHz 3.3v PCI-X , Slot 6: half-length, 32-bit 33MHz 5.0v PCI ports: 4x USB (Vers 2.0), 2x PS/2, parallel, 2x serial (9-pin), VGA, RJ-45 (ethernet ), RJ-45 (sys mgm) HDD 4 x TB 7200rpm / Serial ATA II 3.0Gb/s / 16MB, RoHS

    Read the article

  • Dell Perc 6i with FreeBSD 8.1 errors with mfi0: COMMAND xxxxxxxx TIMEOUT AFTER xxx SECONDS

    - by jDempster
    We've recently bought two Dell PowerEdge R710 servers with Perc 6i controllers and 6x 135GB SAS Drives. We'd done some pretty extensive testing on a Dell PowerEdge R510 server with a Perc 6i and 4x 135GB SAS Drives running FreeBSD 8.1 for it's wonderful ZFS support and mfiutil. We hadn't had any problems with the R510 and had got to a point where we where happy with the performance of ZFS. Since running FreeBSD 8.1 on the R710 we've been getting errors from the RAID controller. mfi0: COMMAND 0xffffff80005d1770 TIMEOUT AFTER 6178 SECONDS This usually brings the system to a stand still. But it doesn't always happen, and performs very well up until it does happen. We've been running the disk as 3 mirrored drives striped in ZFS. So far we've noticed that running the drives with RAID10 on the RAID seems to work without errors (still testing). At first I thought hardware error as we'd been running FreeBSD on the R510 with the same controller without any issues. But both R710 have the same issue. All controllers are running the same firmware.

    Read the article

  • New Dell PE R710 - Storage Question

    - by rihatum
    Hi All, Dell PE R710, received from Dell in the following state : Windows Disk 0 1800GB ( Volume C & D ) Windows Disk 1 526 GB (Volume E ) Perc6i Integrated Raid Controller 6 x 500GB Nearline SAS 7200RPM HDDs Raid 5 Configuration with two Virtual Disks I have installed Dell open Manage and it shows the following : Virtual Disk 0 - State : Background Initialization ( 7% ) Virtual Disk 1 - State : Background Initialization ( 25% ) Now when I click on Virtual Disk 0 it shows me all 6 Disks and the same happens when I click on Virtual Disk 1 it displays all 6 disks. But when I click on Storage Perc6i Connector 0 I get 4 Physical disks with the following numbers : Physical Disk 0:0:0 Physical Disk 0:0:1 Physical Disk 0:0:2 Physical Disk 0:0:3 When I click on Storage Perc6i Connector 1 I get 2 Physical Disks Listed in the following way : Physical Disk 1:0:4 Physical Disk 1:0:5 I am a little confused in this description, does this 1:0:4 interprets to Controller1, Disk4. Does this integrated raid card have two controllers coming out of it ? Also, When I first switched on the machine, the boot partition was showing 1GB Available out of 40GB, now its showing 38GB available out of 40GB. Is this because the Virtual Disks are still Initializing ? Any recommendations or suggestions ? Also, this server have 6 x 500GB NearLine SAS Hard drives, what would be a good raid config ? We are planning to use it for Hyper-V with quite a few (7 or 8) virtual servers, your suggestions would be helpful. Also, while the virtual disks are in a initialization state, can I destroy and re-create the raid configuration ? I would have to do it at the BIOS CTRL-M ? Thanks and Regards

    Read the article

  • cPanel web servers mounting home partition to a NAS or SAN

    - by Scott
    Hello, I currently have 2 cPanel web servers that are little 1RU dual cpu quad core xeons. They have a lot of resources for processing and handling web requests, and never exceed more than 10% cpu usage. They also have plenty of RAM. The problem is though that they both have RAID 1 160Gb SAS hard disk drives in them that are 75% full, and growing by the day. I didnt think that the amount of disk usage would be so high, but due to the nature of the sites hosted, this has become an issue. The easy fix would be just to upgrade the hard drives to something bigger (probably not of the SAS variety), but I am thinking of keeping the current machines as "processing servers" and buying a central "storage server" with about 12TB of storage. The /home/ partition on each of the 1RU servers would be mounted to a NAS or SAN point on this central storage server. My questions are: - Has anyone got a cPanel setup where they mount /home/ to a NAS or SAN elsewhere? If so, can you provide details as to what you did and how it went :) - Any recommendations on networking? Is gigabit ethernet enough? Is TCP/IP going to be a noticable performance problem? Anyone used a TOE key? - Anyone benchmarked or had any performance issues with SAN over NAS? Any help greatly appreciated. Scott

    Read the article

  • Openfiler iSCSI performance

    - by Justin
    Hoping someone can point me in the right direction with some iSCSI performance issues I'm having. I'm running Openfiler 2.99 on an older ProLiant DL360 G5. Dual Xeon processor, 6GB ECC RAM, Intel Gigabit Server NIC, SAS controller with and 3 10K SAS drives in a RAID 5. When I run a simple write test from the box directly the performance is very good: [root@localhost ~]# dd if=/dev/zero of=tmpfile bs=1M count=1000 1000+0 records in 1000+0 records out 1048576000 bytes (1.0 GB) copied, 4.64468 s, 226 MB/s So I created a LUN, attached it to another box I have running ESXi 5.1 (Core i7 2600k, 16GB RAM, Intel Gigabit Server NIC) and created a new datastore. Once I created the datastore I was able to create and start a VM running CentOS with 2GB of RAM and 16GB of disk space. The OS installed fine and I'm able to use it but when I ran the same test inside the VM I get dramatically different results: [root@localhost ~]# dd if=/dev/zero of=tmpfile bs=1M count=1000 1000+0 records in 1000+0 records out 1048576000 bytes (1.0 GB) copied, 26.8786 s, 39.0 MB/s [root@localhost ~]# Both servers have brand new Intel Server NIC's and I have Jumbo Frames enabled on the switch, the openfiler box as well as the VMKernel adapter on the ESXi box. I can confirm this is set up properly by using the vmkping command from the ESXi host: ~ # vmkping 10.0.0.1 -s 9000 PING 10.0.0.1 (10.0.0.1): 9000 data bytes 9008 bytes from 10.0.0.1: icmp_seq=0 ttl=64 time=0.533 ms 9008 bytes from 10.0.0.1: icmp_seq=1 ttl=64 time=0.736 ms 9008 bytes from 10.0.0.1: icmp_seq=2 ttl=64 time=0.570 ms The only thing I haven't tried as far as networking goes is bonding two interfaces together. I'm open to trying that down the road but for now I am trying to keep things simple. I know this is a pretty modest setup and I'm not expecting top notch performance but I would like to see 90-100MB/s. Any ideas?

    Read the article

  • Dell Poweredge 1950 with Perc 5i keeps losing raid config -> "Foreign Configuration Found"

    - by nosage
    The quick and dirty: the machine is a Dell Poweredge 1950, dual xeon quad cores, 8GB of ram, 2 2TB seagate SATAs in (supposed to be raid1) using a Perc 5i raid card. They are hot-swappable with a back-plane. I can build the raid fine and after a little while an install of server 08 r2 will blue screen and restart. When it comes up the raid controller says "Foreign Configuration Found." When I go into the raid configuration panel there is no raid listed but I can import the "foreign config", and the OS will boot up fine, until it blue screens again after a little while. The issue is OS independent. I have tried swapping raid cards, swapping the RAM module on the raid card and swapping the raid battery, all to no avail. Its almost as if there is a loose connection from the raid card to the back plane and both of disks get lost and the raid card drops the config. But it sees the disks fine when it boots back up. The raid card uses a SCSI SAS cable to connect to the back-plane so I guess the next step is to replace that, but... then I might as well replace the back-plane with a SCSI SAS to sata breakout cable, but... then I need a way to power the disks. Sorry for the wall of txt but it would be great to get some thoughts from people who worked with perc raid cards or poweredge servers with this type of issue before. Ironically I want to get this system up and running so I can work on MCITP labs. Thank you for any/all help and feel free to ask questions!

    Read the article

  • cPanel web servers mounting home partition to a NAS or SAN

    - by Scott
    I currently have 2 cPanel web servers that are little 1RU dual cpu quad core xeons. They have a lot of resources for processing and handling web requests, and never exceed more than 10% cpu usage. They also have plenty of RAM. The problem is though that they both have RAID 1 160Gb SAS hard disk drives in them that are 75% full, and growing by the day. I didnt think that the amount of disk usage would be so high, but due to the nature of the sites hosted, this has become an issue. The easy fix would be just to upgrade the hard drives to something bigger (probably not of the SAS variety), but I am thinking of keeping the current machines as "processing servers" and buying a central "storage server" with about 12TB of storage. The /home/ partition on each of the 1RU servers would be mounted to a NAS or SAN point on this central storage server. My questions are: - Has anyone got a cPanel setup where they mount /home/ to a NAS or SAN elsewhere? If so, can you provide details as to what you did and how it went :) - Any recommendations on networking? Is gigabit ethernet enough? Is TCP/IP going to be a noticable performance problem? Anyone used a TOE key? - Anyone benchmarked or had any performance issues with SAN over NAS? Any help greatly appreciated. Scott

    Read the article

  • Slow parity initialization of RAID-5 array on HP Smart Array 411 controller

    - by Rob Nicholson
    On 29th October 2011, I built a RAID-5 array using 4 x 146.8GB Seagate SAS ST3146855SS drives running at 15k connected to a PowerEdge R515 with HP Smart Array P411 controller running Windows 2008 (so nothing particularly unusual). I know that parity initialisation of a RAID-5 array can take some time but it's still running after 2.5 weeks which seems a little unusual. I'd previously built another array on the same controller using 4 x 2TB SATA-2 drives and that did take a while to complete but a) I'm sure it was less than 2.5 weeks, b) that array was ~12 times bigger and c) during initialization, the percentrage slowly increased each day. At the moment, the status display for this new 2nd array simply says "Parity Initialization Status: In Progress" and it's said that since the start. It's this lack of change on the status that worries me the most - feels like it's not actually doing anything. Do you think something has gone wrong or am I being unpatient and for some reason, the status not increasing is normal? I kind of expected a much smaller array on faster drives (15k SAS versus 7.5k SATA-2) to build in a few days. This is our primary SAN running StarWind so my "have a play" options are very limited. This 2nd array is currently in use for one small virtual disk so I could shut the target machine down, move the virtual disk to another drive and try rebuilding.

    Read the article

  • What does this mean: "SATP VMW_SATP_LOCAL does not support device configuration"?

    - by Jason Tan
    Can anyone tell me what this means in ESXi 5.1?: SATP VMW_SATP_LOCAL does not support device configuration I've googled it and I get a lot of results, but as yet all the pages that contain the string are discussing other matters. The storage array is a HDS HUS-VM and the hosts are HP b460c G8 blades with flex fabric and flex fabric VCs which I am in the process of commissioning and would like to get it started on the right foot - i.e. error and warning free! naa.600508b1001c56ee3d70da65f071da23 Device Display Name: HP Serial Attached SCSI Disk (naa.600508b1001c56ee3d70da65f071da23) Storage Array Type: VMW_SATP_LOCAL Storage Array Type Device Config: SATP VMW_SATP_LOCAL does not support device configuration. Path Selection Policy: VMW_PSP_FIXED Path Selection Policy Device Config: {preferred=vmhba0:C0:T0:L1;current=vmhba0:C0:T0:L1} Path Selection Policy Device Custom Config: Working Paths: vmhba0:C0:T0:L1 Is Local SAS Device: true Is Boot USB Device: false This is the same LUN: ~ # esxcli storage core device list -d naa.60060e80132757005020275700000016 naa.60060e80132757005020275700000016 Display Name: HITACHI Fibre Channel Disk (naa.60060e80132757005020275700000016) Has Settable Display Name: true Size: 204800 Device Type: Direct-Access Multipath Plugin: NMP Devfs Path: /vmfs/devices/disks/naa.60060e80132757005020275700000016 Vendor: HITACHI Model: OPEN-V Revision: 5001 SCSI Level: 2 Is Pseudo: false Status: degraded Is RDM Capable: true Is Local: false Is Removable: false Is SSD: false Is Offline: false Is Perennially Reserved: false Queue Full Sample Size: 0 Queue Full Threshold: 0 Thin Provisioning Status: unknown Attached Filters: VAAI_FILTER VAAI Status: supported Other UIDs: vml.020001000060060e801327570050202757000000164f50454e2d56 Is Local SAS Device: false Is Boot USB Device: false ~ #

    Read the article

  • Dell R320 RAID 10 with CacheCade

    - by Geekman
    I'm looking for a higher-performance build for our 1RU Dell R320 servers, in terms of IOPS. Right now I'm fairly settled on: 4 x 600 GB 3.5" 15K RPM SAS RAID 1+0 array This should give good performance, but if possible, I want to also add an SSD Cache into the mix, but I'm not sure if there's enough room? According to the tech-specs, there's only up to 4 total 3.5" drive bays available. Is there any way to fit at least a single SSD drive along-side the 4x3.5" drives? I was hoping there's a special spot to put the cache SSD drive (though from memory, I doubt there'd be room). Or am I right in thinking that the cache drives are simply drives plugged in "normally" just as any other drive, but are nominated as CacheCade drives in the PERC controller? Are there any options for having the 4x600GB RAID 10 array, and the SSD cache drive, too? Based on the tech-specs (with up to 8x2.5" drives), maybe I need to use 2.5" SAS drives, leaving another 4 bays spare, plenty of room for the SSD cache drive. Has anyone achieved this using 3.5" drives, somehow?

    Read the article

  • HP DL185 - very slow disk read speed

    - by fistameeny
    Hi, I have a HP DL185 G6 Server (12 disk model) with the following spec: Quad Core Xeon 2.27GHz 6GB RAM HP P212 RAID controller with battery backup 2 x 128GB 15K SAS 3.5" (RAID-1 for the operating system) 4 x 750GB 7.5K SAS 3.5" (RAID-5 for the data, 2TB usable space) The operating system is Ubuntu Server 9.10. Both drives have been formatted as EXT4. We are finding that read speed of the RAID-5 array is poor. Disk test results below: sudo hdparm -tT /dev/cciss/c0d1p1 /dev/cciss/c0d1p1: Timing cached reads: 15284 MB in 2.00 seconds = 7650.18 MB/sec Timing buffered disk reads: 74 MB in 3.02 seconds = 24.53 MB/sec For info, the RAID-1 array performs as follows: sudo hdparm -tT /dev/cciss/c0d0p1 /dev/cciss/c0d0p1: Timing cached reads: 15652 MB in 2.00 seconds = 7834.26 MB/sec Timing buffered disk reads: 492 MB in 3.01 seconds = 163.46 MB/sec We thought this was because with no battery, read/write cache is disabled. We have bought and installed the battery backup and have used the HP bootable CD to change the cache settings to 50% read / 50% write and check cache is enabled on the drives and the controller. Is there something I'm missing?

    Read the article

  • Disable RAID to JBOD in server IBM x3400 M2

    - by BanKtsu
    Hi I just wanna disable the default RAID in my server IBM System X3400 M2 Server(7837-24X),i have 3 disk drives SAS. I want to make them a JBOD "Just a Bunch Of Disks", because I want to install in the drive 0 CentOS, and the other two make them cache files for a squid server. I disable the RAID in the BIOS: System Settings/Adapters and UEFI drivers/LSI Logic Fusion MPT SAS Driver -PciRoot(0x0)/Pci(0x3,0X0)/Pci(0x0,0x0) LSI Logic MPT Setup Utility RAID Properties/Delete Array Later I boot the CentOS live CD and install the OS in the drive 0, and the others 2 mounted like this: *LVM Volume Groups vg_proxyserver 139508 lv_root 51200 / ext4 lv_home 84276 /home ext4 lv_swap 4032 Hard Drive sdb(/dev/sdb) free 140011 sdc(/dev/sdc) free 140011 sdd(/dev/sdd) sdd1 500 /boot ext4 sdd2 139512 vg_proxyserver physical volume(LVM) But when I restart the server give me the error: Boot failed Hard Disk 0 UEFI PXE PciRoot(0x0)/Pci(0x1,0X0)/Pci(0x0,0x0)/MAC(001A64B15130,0X0)) ........PXE-E18:Server response timeout. UEFI PXE PciRoot(0x0)/Pci(0x1,0X0)/Pci(0x0,0x0)/MAC(001A64B15132,0X0)) ........PXE-E18:Server response timeout. and the OS not start. The IBM force me to do a RAID?,why?

    Read the article

  • Building vs buying a server for an academic lab [closed]

    - by Roy
    I'm looking for advice on the classic build vs buy question. We need a new linux server to run Matlab computation on in our lab (academic). Matlab parallel computing toolbox licence allows up to 12 local workers so we are aiming at a 12 core server with 4GB memory per core (total of 48gb). The system will have an SSD for the OS and a raid-5 (4x2tb) for data. I looked around and found a (relatively) cheap vendor, Silicon Mechanics, that offers a system to our liking (specs below) for $6732. However, buying the components from newegg cost only $4464! The difference is $2268 which is 50% of the base cost. If buying from a company can be thought of as a sort of insurance, basically my premiums are of 50% of the base cost which to me sounds like a lot. Of course any downtime is bad, but the work is not "mission critical", i.e. if it takes a few days to fix it when it breaks its no the end of the world. If it takes weeks to months then its a problem. If it breaks 2-3 times in 3 years, not too bad. If it breaks every month not good. In term of build experience, I set up a linux cluster in grad school (from existing computers) and I build my home pcs but I never built a server before. The server components I'm thinking about: 1 x SUPERMICRO SYS-7046T-6F 4U Tower Server Barebone Dual LGA 1366 Intel 5520 DDR3 1333/1066/800 ($1,050) 12 x Kingston 4GB 240-Pin DDR3 SDRAM DDR3 1333 (PC3 10600) ECC Unbuffered Server Memory ($420) 2 x Intel Xeon E5645 Westmere-EP 2.4GHz LGA 1366 80W Six-Core ($1,116) 4 x Seagate Constellation ES 2TB 7200 RPM SATA 6.0Gb/s 3.5" ($1,040) 1 x SAMSUNG Internal DVD Writer Black SATA ($20) 1 x Intel 520 Series 2.5" 180GB SATA III MLC SSD $300 1 x LSI LSI00281 PCI-Express 2.0 x8 MD2 Low profile SATA / SAS MegaRAID SAS 9260CV-4i Controller Card, $695

    Read the article

  • RAID 10 or RAID 5 for multiple VMs - what is the best choice?

    - by Lars Fastrup
    I have just ordered a new rig for my business. We do a lot of software development for Microsoft SharePoint and need the rig to run several virtual machines for development and test purposes. We will be using the free VMware ESXi for virtualization. For a start, we plan to build and start the following VMs - all with Windows Server 2008 R2 x64: Active Directory server MS SQL Server 2008 R2 Automated Build Server SharePoint 2010 Server for hosting our public Web site and our internal Intranet for a few people. The load on this server is going to be quite insignificant. 2xSharePoint 2007 development server 2xSharePoint 2010 development server Beyond that we will need to build several SharePoint farms for testing purposes. These VMs will only be started when needed. The specs of the new rig is: Dell R610 rack server 2xIntel XEON E5620 48GB RAM 6x146GB SAS drives Dell H700 RAID controller We believe the new server is going to make our VMs perform a lot better than our existing setup (2xIntel XEON, 16GB RAM, 2x500 GB SATA in RAID 1). But we are not sure about the RAID level for the new rig. Should we go for having the the 6x146GB SAS drives in a RAID 10 configuration or a RAID 5 configuration? RAID 10 seems to offer better write performance and lower risk of a RAID failure. But it comes at a cost of less drive space. Do we need RAID 10 or would RAID 5 also be a good choice for us?

    Read the article

  • Cisco ASA site-to-site vpn not initiating phase 1 (not sending udp 500 packets)

    - by Sean Steadman
    I am hoping someone here can help me with my problem. I am trying to setup an IPSEC site-to-site VPN between two cisco ASA 5520's in GNS3 (both using 8.4.2). I have been unsuccesful in getting the tunnel up and it appears neither ASA is sending packets out,in regards to phase 1 and phase 2 (tested by using wireshark and seeing NO udp 500 packets). Doing show ipsec sa and such shows nothing. CALIFORNIA(config)# show ipsec sa There are no ipsec sas FLA-ASA# show ipsec sa There are no ipsec sas I will attach both configurations in two different pastebin files as to keep this post a bit cleaner. Essentially California side has 172.20.1.0/24 and Florida side has 10.10.10.0/24. California ASA config: http://pastebin.com/v0pngYzF Florida ASA config: http://pastebin.com/E2geybta Please let me know if there is any other vital information that could help. I have gotten IPSEC tunnels to work using openSwan (linux) and cisco routers but cannot for the life of me get ASA IPSEC tunnels to work. The ASDM is out of the question I only use cli. Thanks for any useful help!

    Read the article

  • IBM BladeCenter S: Disk Configuration

    - by gravyface
    Have just the one storage bay right now (SAS 15K 600GB x 6) and have configured one storage pool in RAID 10 with 4 disks (and two global spares). For each blade, I've created a volume and mapped accordingly: Blade #1 400 GB Blade #2 200 GB Blade #3 100 GB Blade #4 100 GB When I boot up Blade 1 and enter into the UEFI Setup (F1) followed by the Adapters and UEFI Drivers LSI Logic Fusion MPT SAS Driver Utility, I see 4 disks: two are the on-board 73GB drives, the other two are 200GB each and assume I'm being presented with two logical disks from the volume I created and mapped to this blade. I was a bit surprised by this: I figured I would've been presented with one logical drive per volume, not two. I'm assuming I can just configure whatever RAID level I wish that supports two disks, but not really sure what the benefits/trade-offs here. Should I go with RAID 10 on top of RAID 10? RAID 0? Software RAID 0/1/10? Does it even matter? If this is "normal" to see two disks, then I'm going to likely just do some benchmarking and see if it makes a difference changing the RAID levels (my guess is no); if this is not normal, well, please let me know. :)

    Read the article

  • HPET missing from available clocksources on CentOS

    - by squareone
    I am having trouble using HPET on my physical machine. It is not available, even though I have enabled it in my bios, forced it in grub, and triple checked my kernel to include HPET in its compilation. Motherboard: Supermicro X9DRW Processor: 2x Intel(R) Xeon(R) CPU E5-2640 SAS Controller: LSI Logic / Symbios Logic SAS2004 PCI-Express Fusion-MPT SAS-2 [Spitfire] (rev 03) Distro: CentOS 6.3 Kernel: 3.4.21-rt32 #2 SMP PREEMPT RT x86_64 GNU/Linux Grub: hpet=force clocksource=hpet .config file: CONFIG_HPET_TIMER=y CONFIG_HPET_EMULATE_RTC=y CONFIG_HPET=y dmesg | grep hpet: Command line: ro root=/dev/mapper/vg_xxxx-lv_root rd_NO_LUKS rd_LVM_LV=vg_xxxx/lv_root KEYBOARDTYPE=pc KEYTABLE=us rd_NO_MD SYSFONT=latarcyrheb-sun16 crashkernel=auto rd_LVM_LV=vg_xxxx/lv_swap rd_NO_DM LANG=en_US.UTF-8 rhgb quiet panic=5 hpet=force clocksource=hpet Kernel command line: ro root=/dev/mapper/vg_xxxx-lv_root rd_NO_LUKS rd_LVM_LV=vg_xxxx/lv_root KEYBOARDTYPE=pc KEYTABLE=us rd_NO_MD SYSFONT=latarcyrheb-sun16 crashkernel=auto rd_LVM_LV=vg_xxxx/lv_swap rd_NO_DM LANG=en_US.UTF-8 rhgb quiet panic=5 hpet=force clocksource=hpet cat /sys/devices/system/clocksource/clocksource0/current_clocksource: tsc cat /sys/devices/system/clocksource/clocksource0/available_clocksource: tsc jiffies What is even more confusing, is that I have about a dozen other machines that utilize the same kernel .config, and can use HPET fine. I fear it is a hardware issue, but would appreciate any advice or help with getting HPET available. Thanks in advance!

    Read the article

  • Server periodically freezing - Help Stabilizing

    - by JonDog
    We run an asp.net/sql server data collection website with a hand full of clients dumping data in and running reports. We moved to a new server (specs below) and have had issues with it freezing and having to reboot it a dozen times over the pass six months. The hosting company has mentioned possible causes (listed below) but cant give a definite answer on what is going wrong. They have offered to reconfigure how ever I like. We have benefited from having a much faster system and really dont want to get rid of the ssd's unless they are the issue. Two possible setup changes that I've talked with them about are also listed below. Any suggestions on what maybe causing the freezing issue as well as suggestion on a new setup would be great. My main questions are: Do SSD generally have problems running the OS & SQL Server on the same RAID Array? and Are the new SSD's still unrefined enough to be running in a production environment? Thanks Current: Xeon Quad Core E3-1270 3.40 Ghz 16 GB DDR3-1333 ECC SDRAM First Hard Drive: 120GB Intel SSD Second Hard Drive: 120GB Intel SSD Third Hard Drive: 120GB Intel SSD Fourth Hard Drive: 120GB Intel SSD SAS 4 Port RAID Card Windows 2012 Standard Edition - 64 Bit MSSQL 2008 Web Edition Possible Causes: Running Sql Server & OS on same RAID Array OS Software Issues Using SSD's CPU Underpowered Not enough RAM Option 1 2x Xeon Quad Core E5-2603 1.80 GHz 16 GB DDR3-1333 ECC SDRAM 1 x 240GB Intel SSD - OS 3 x 1 TB SATA HDD (7200 RPM) - SQL Server SATA 4 Port RAID Card Windows 2012 Standard Edition - 64 Bit Option 2 Dell PowerEdge E3-1270v2 3.5GHz 4 Cores 16 GB DDR3-1600 UDIMM 4 x 128 GB Samsung 840 Pro SSD Add-in H200 (SAS/SATA Controller), 4 Hard Drives - RAID 10 Windows 2012 Standard Edition - 64 Bit