Search Results

Search found 95133 results on 3806 pages for 'switch user'.

Page 28/3806 | < Previous Page | 24 25 26 27 28 29 30 31 32 33 34 35  | Next Page >

  • ProCurve 1800 switch issue

    - by user98651
    I recently deployed ProCurve 1800-24G switches in place of some older ProCurve 2424M switches in my network. However, I'm having a serious problem with the switch connected to the router. It seems, every night when our Windows 2008 R2 server (off site) runs a backup to a iSCSI target (on site) [facilitated through a PPTP tunnel] the LAN loses connectivity with the router. To clarify, there is only one router which is connected to the switch affected by this problem. The only way to resolve the issue is to either reboot the router or pull the ethernet cable that goes to the router and plug it back in. During the outage, clients cannot receive DHCP requests, DNS requests, ping, or do anything else with the router in this state. Now, neither the switch or router are configured extensively and the issue only seems to have surfaced with the new switch in place. I have tried a number of things including replacing cables, rebooting and checking the switch configuration (it is literally as basic as you can get at this point-- flat LAN, no trunking). Interestingly, the router shows (accessed externally) no changes in configuration or status during this state but similarly cannot ping or access other hosts on the network. This issue occurs in different stages of backup (ie, different amounts transferred). I've also dumped packets from the switch into WireShark but cannot seem to find any anomaly yet (I'm looking at packets around the time the issue appeared and at the time when I reset the NIC). Any suggestions for what to look for? Ideas on what could be causing this? I'm seeing some transmit/receive errors on the NIC from both the router and switch side but nothing serious when compared to the total packet counts. I'm seriously doubting hardware at this point, as I have tried another switch, different cables, and a different NIC on the router.

    Read the article

  • Problems in user - registration module in DRUPAL

    - by Nitz
    Hello Guys, I have some problem in drupal registration page. I want to change whole user registration page. in registration module i want to add new field type. Bcz i want that user can choose the date from date-time picker. I have ready date-time picker which i have implement, but i don't know where to put that code. I want to add validation on new added text fields. Means i have added one text field for Phone no, so now i want to check if user had only entered the numbers.....in new user registration page. Thanks in advance Nitish

    Read the article

  • User authentication using CodeIgniter

    - by marcin_koss
    I have a problem creating authentication part for my application. Below is the simplified version of my controllers. The idea is that the MY_controller checks if session with user data exists. If it doesn’t, then redirects to the index page where you have to log in. MY_controller.php class MY_Controller extends Controller { function __construct() { parent::__construct(); $this->load->helper('url'); $this->load->library('session'); if($this->session->userdata('user') == FALSE) { redirect('index'); } else { redirect('search'); } } } order.php - main controller class Orders extends MY_Controller { function __construct() { parent::__construct(); $this->load->helper('url'); $this->load->library('session'); } function index() { // Here would be the code that validates information input by user. // If validation is successful, it creates user session. $this->load->view('header.html', $data); // load header $this->load->view('index_view', $data); // load body $this->load->view('footer.html', $data); // load footer } function search() { //different page } what is happening is that the browser is telling me that “The page isn’t redirecting properly. Firefox has detected that the server is redirecting the request for this address in a way that will never complete.” It seems like the redirect() is being looped. I looked at a few other examples of user auth and they were build using similar technique.

    Read the article

  • Adding to the browser user agent string?

    - by stwissel
    I have a plug-in that handles its own url schema (something like mystuf:// ). If a user clicks on such a link when the plug-in isn't installed (s)he gets an ugly error. So I extended my installer to write into the Registry (for Internet Explorer) and the user.js (for Firefox) to ADD a custom string to the user agent string. These additions survive a browser upgrade nicely (Microsoft uses this technique to indicate the presence of the dotNet Framework). Now I need to extend this to Apple Safari and Google Chrome on all supported platforms. To be clear: I'm not looking how to REPLACE the user agent string, but how to amend it with additional information. Any hint?

    Read the article

  • Best way to save user settings on client-side (javascript,jquery)

    - by Johua
    I have a settings page that a user can enter some text and save directly to a combobox. Next time when page loads, combobox is filled in with the previous entered text. Also i have a modify button, so the user can delete or edit a value from the combobox. My question is, what's the best way to save to user settings on the client with javascirpt/jquery? I can only think of using an array and then (push/pop).,,Anyone got some bad experience with arrrays? thx

    Read the article

  • Drupal 7: cancel user registration if a wrong field value has been submitted.

    - by Alexander Farber
    Hello, I have a Drupal 7 with 1 field added to registration form - a List with possible values Robot / Male / Female: # select * from field_data_field_gender; entity_type | bundle | deleted | entity_id | revision_id | language | delta | field_gender_value -------------+--------+---------+-----------+-------------+----------+-------+-------------------- user | user | 0 | 6 | 6 | und | 0 | Male user | user | 0 | 5 | 5 | und | 0 | Male user | user | 0 | 7 | 7 | und | 0 | Female user | user | 0 | 1 | 1 | und | 0 | Male The first value Robot is a default value - to prevent SPAM robots from registering at my site. Is there a way to cancel user registration, when a new user submits the registration web form with the default Robot value? (i.e. only Male and Female values are allowed). I've looked at the core Trigger module, but don't see anything suitable there. I've looked at the hook_user_presave and hook_user_insert API docs, but don't see a way there to cancel an ongoing user registration. (I was expecting to do that by returning a special value from those methods...) Thank you! Alex

    Read the article

  • Assign Multiple Custom User Roles to a Custom Post Type

    - by OUHSD Webmaster
    Okay here's the situation.... I'm working on a my business website. There will be a work/portfolio area. "Work" is a custom post type. "Designer" is a custom user role. "Client" is a custom user role. In creating a new "Work" post I would like to be able to select both a "designer" and "Client" to assign to the piece of work, as I would assign an author to a regular ol' post. I tried the method from this answer but it did not work for me. ) I placed it in my functions.php file. ` add_filter('wp_dropdown_users', 'test'); function test($output) { global $post; //Doing it only for the custom post type if($post->post_type == 'work') { $users = get_users(array('role'=>'designer')); //We're forming a new select with our values, you can add an option //with value 1, and text as 'admin' if you want the admin to be listed as well, //optionally you can use a simple string replace trick to insert your options, //if you don't want to override the defaults $output .= "<select id='post_author_override' name='post_author_override' class=''>"; foreach($users as $user) { $output .= "<option value='".$user->id."'>".$user->user_login."</option>"; } $output .= "</select>"; } return $output; } ` Any help would be extremely appreciated!

    Read the article

  • does a switch idiom make sense in this case?

    - by the ungoverned
    I'm writing a parser/handler for a network protocol; the protocol is predefined and I am writing an adapter, in python. In the process of decoding the incoming messages, I've been considering using the idiom I've seen suggested elsewhere for "switch" in python: use a hash table whose keys are the field you want to match on (a string in this case) and whose values are callable expressions: self.switchTab = { 'N': self.handleN, 'M': self.handleM, ... } Where self.handleN, etc., are methods on the current class. The actual switch looks like this: self.switchTab[selector]() According to some profiling I've done with cProfile (and Python 2.5.2) this is actually a little bit faster than a chain of if..elif... statements. My question is, do folks think this is a reasonable choice? I can't imagine that re-framing this in terms of objects and polymorphism would be as fast, and I think the code looks reasonably clear to a reader.

    Read the article

  • Trigger user control post back from client side

    - by Narmatha Balasundaram
    Can a post back to the user control be triggered from javascript (on the client side) without updatepanels? What I am trying to achieve is this Initially the page and the user control are loaded with default values The parent pages makes a PageMethod request When the data is available (from the PageMethod request), the user control has to be reloaded to update with the new values

    Read the article

  • Managing User Profiles with PHP/MySQL for Beginners

    - by serhio
    I am beginner in PHP/MySql and would develop a simple site that has user management. I like the idea of using OpenId's (like stackoverflow uses). I wonder from where to start? What should I read? I have not much time so probably will net enter in all details of PHP user session management, this because I search something like User profiles management in PHP for dummies 8D Environment: Linux OS Apache 2.2.15 MySQL 5.1.41 PHP 5.2.13 cPanel 11.25.0

    Read the article

  • Link Button on asp.net user control not firing

    - by andyriome
    Hi I have a user control, which is added to another user control. The nested user control is built up of a gridview, an image button and a link button. The nested user control is added to the outer control as a collection object based upon the results bound to the gridview. The problem that I have is that my link button doesn't work. I click on it and the event doesn't fire. Even adding a break point was not reached. As the nested user control is added a number of times, I have set image button to have unique ids and also the link button. Whilst image button works correctly with its java script. The link button needs to fire an event in the code behind, but despite all my efforts, I can't make it work. I am adding the link button to the control dynamically. Below is the relevant code that I am using: public partial class ucCustomerDetails : System.Web.UI.UserControl { protected override void CreateChildControls( ) { base.CreateChildControls( ); string strUniqueID = lnkShowAllCust.UniqueID; strUniqueID = strUniqueID.Replace('$','_'); this.lnkShowAllCust.ID = strUniqueID; this.lnkShowAllCust.Click += new EventHandler(this.lnkShowAllCust_Click); this.Controls.Add(lnkShowAllCust); } protected override void OnInit (EventArgs e) { CreateChildControls( ); base.OnInit(e); } protected override void OnLoad(EventArgs e) { base.EnsureChildControls( ); } protected void Page_Load(object sender, EventArgs e) { if (IsPostBack) { CreateChildControls( ); } } protected void lnkShowAllCust_Click(object sender, EventArgs e) { this.OnCustShowAllClicked(new EventArgs ( )); } protected virtual void OnCustShowAllClicked(EventArgs args) { if (this.ViewAllClicked != null) { this.ViewAllClicked(this, args); } } public event EventHandler ViewAllClicked; } I have been stuggling with this problem for the last 3 days and have had no success with it, and I really do need some help. Can anyone please help me?

    Read the article

  • Validation on user registration form ?

    - by Nitz
    Hey Guys, i have made module in which i am trying to add validation like if the user had entered the characters in "Phone No" text filed and same on "Mobile No". This will run when user had open the user registration form. I have made this.... <?php function form_intro_form_alter(&$form,&$form_state,$form_id){ if($form_id == 'user_register' || $form_id == 'user_edit'){ $form['Personal Information']['profile_pno']['#validate'] = array('form_intro_pno_validate' => array()); //profile_pno is for Phone No. $form['Personal Information']['profile_mno']['#validate'] = array('form_intro_mno_validate' => array()); //profile_mno is for Mobile No. } } function form_intro_pno_validate($element){ if(!is_numeric($element['#value'])){ form_set_error('profile_state' , t('Please Enter Only Number in Phone no')); } } function form_intro_mno_validate($element){ if(!is_numeric($element['#value'])){ form_set_error('profile_state' , t('Please Enter Only Number in Mobile no')); } } ?> the module name is form_intro..... plz check it and send me replay... this isn't working...it not giving any error when user had entered the characters.

    Read the article

  • Multiple user database design

    - by dieguitoweb
    I have to develop a basic social network for an academic purpose; but I need some tips for the users management.. The users are subdivided into 3 groups with different privilege: admins,analysts and standards users. For every user should be stored into the database the following information: name,lastname,e-mail,age,password. I'm not quite sure how I should design the database between theese two solutions: 1)one table called 'users' with the 'role' attribute that explain what a user can do and what can't do, and the permissions are managed via php 2)every application user is a database user created with the query 'CREATE ROLE' (It's a postgres database) and he has permissions on some tables granted with the 'GRANT' statement You should take into account that the project is for a database exam.. thanks

    Read the article

  • Can my thread help the OS decide when to context switch it out?

    - by WilliamKF
    I am working on a threaded application on Linux in C++ which attempts to be real time, doing an action on a heartbeat, or as close to it as possible. In practice, I find the OS is swapping out my thread and causing delays of up to a tenth of a second while it is switched out, causing the heartbeat to be irregular. Is there a way my thread can hint to the OS that now is a good time to context switch it out? I could make this call right after doing a heartbeat, and thus minimize the delay due to an ill timed context switch.

    Read the article

  • drupal multiple interest of user

    - by Arun
    hi i want to refresh user page with different data but with same template (user-profile.tpl.php) by simply clicking tabs. Can any one suggest the best way to do that ?. for ex: tab1:sports , tab2: music tab3: literature by clicking tabs the template is same but the data is going to refreshed. Note: Look like profile categories but not the same. all details are from user table

    Read the article

  • Configuring VLAN's on two HP procurve switches

    - by pan
    Trying to route a new ISP (Microwave link) from one of my out buildings to my computer room and hence my firewall. Old ISP came direct into firewall. In the outbuilding the Microwave modem connects with cat5 to HP Procurve 2524 switch. Because this ISP is coming through my internal network, I plan on using a new vlan called "airspeed" only for this ISP traffic. Up until now I've just been using the Default_vlan on both HP switches (4108 + 2524). So far I've been unable to ping from my laptop to the ISP modem both of which are on the new vlan 2 ("Airspeed"). No traffic needs to cross from vlan 2 to vlan 1 so I've left the ports as untagged. I've used the subnet provide from my ISP as the new vlan 2 subnet. Can anybody see what I'm doing wrong here? I've added the configuration of both switch below. Rough diagram: Microwave modem (Gateway IP 77.75.00.49) | HP 2524 switch (port 24) | HP 2524 switch fibre link | HP 4108GL switch fibre link | HP 4108GL switch (port D1) | Laptop configured with IP 77.75.00.50 (for testing but will be connected to firewall) And my 4108GL config: ; J4865A Configuration Editor; Created on release #G.07.21 hostname "HP ProCurve Switch 4108GL" cdp run module 1 type J4864A module 2 type J4862B module 3 type J4862B module 4 type J4862B ip default-gateway 128.1.146.50 snmp-server community "public" Unrestricted snmp-server host 128.1.146.51 "public" Not-INFO snmp-server host 128.1.146.38 "public" vlan 1 name "DEFAULT_VLAN" untagged A1-A3,B1-B24,C1-C24,D2-D24 ip address 128.1.146.203 255.255.0.0 no untagged D1 exit vlan 2 name "Airspeed" untagged D1 ip address 77.75.00.51 255.255.255.248 exit Finally my 2524 config: ; J4813A Configuration Editor; Created on release #F.04.08 hostname "HP ProCurve Switch 2524" cdp run ip default-gateway 0.0.0.0 snmp-server community "public" Unrestricted snmp-server host 128.1.146.51 "public" Not-INFO snmp-server host 128.1.146.51 "public" snmp-server host 128.1.146.38 "public" vlan 1 name "DEFAULT_VLAN" untagged 1-23,25-26 no untagged 24 ip address 128.1.146.204 255.255.0.0 exit vlan 2 name "Airspeed" untagged 24 ip address 77.75.00.51 255.255.255.248 exit no aaa port-access authenticator active

    Read the article

  • Enable Multi-Column Google Searches with a User Script

    - by Asian Angel
    Are you wanting to improve the search results view at Google and make better use of the webpage space? With a little user script magic you can make those search results look and fit better in your favorite browser. Note: This user script may conflict with the AutoPager extension if you have it installed in your favorite browser. Before Here is the standard single column view of search results at Google. Not too bad but the available space could certainly be better utilized. Note: For the purposes of our example we are using Google Chrome but this user script can be easily added to other browsers. After If you have never installed a user script in Chrome before it is just as simple as the regular extensions at the official Google website. Here you can see the details for the user script we are installing. Notice that you can view the source code if desired. To add the user script to Chrome click on “Install”. Once you start the install process you will see an intermediary message asking if you wish to continue in the lower left corner of your browser. Click “Continue” to move to the next step in the install process. From this point on the install process is practically identical to the official extensions. You can see the final confirmation window here…click “Install” to finish adding the user script to Chrome. As with regular extensions you will see a post-install message in the upper right corner. So, what does a user script look like in the “Extensions Page”? You can see the user script entry here…outside of an icon it looks rather identical to a normal extension. After refreshing the search page shown above we now have two columns of search results (default setting). This looks much much better than a single column view and there is little to no page scrolling required now. To switch to a three column view simply use the keyboard shortcut “Alt + 3”. To return to a single column view use “Alt + 1” and for the default two column view use “Alt + 2”. Three keyboard shortcuts for three different views…definitely a good thing. Note: On our test system we needed to use the number keys at the top of our keyboard to switch views…this is most likely the result of unique settings on our test system. Conclusion If you are wanting a better viewing experience when conducting searches at Google then this user script will make a very nice addition to your favorite browser. For those using Firefox you can add user scripts with the Greasemonkey & Stylish extensions. Using Opera Browser? See our how-to for adding user scripts to Opera here. Links Install the Multi-Column View of Google Search Results User Script Similar Articles Productive Geek Tips Hide Flash Animations in Google ChromeEnable Google Search From Shortcut Key in KDE on (k)UbuntuSet Gmail as Default Mail Client in UbuntuSet Up User Scripts in Opera BrowserHow To Enable Favicons for Google Reader Subscriptions TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Yes, it’s Patch Tuesday Generate Stunning Tag Clouds With Tagxedo Install, Remove and HIDE Fonts in Windows 7 Need Help with Your Home Network? Awesome Lyrics Finder for Winamp & Windows Media Player Download Videos from Hulu

    Read the article

  • OCS 2007 R2 User Properties Error Message

    - by BWCA
    When I attempted to configure one of our user’s Meeting settings using the Microsoft Office Communications Server 2007 R2 Administration Tool   I received an Validation failed – Validation failed with HRESULT = 0XC3EC7E02 dialog box error message. I received the same error message when I tried to configure the user’s Telephony and Other settings. Using ADSI Edit, I compared the settings of an user that I had no problems configuring and the user that I had problems configuring.  For the user I had problems configuring, I noticed a trailing space after the last phone number digit for the user’s msRTCSIP-Line attribute. After I removed the trailing space for the attribute and waited for Active Directory replication to complete, I was able to configure the user’s Meeting settings (and Telephony/Other settings) without any problems. If you get the error message, check your user’s msRTCSIP-xxxxx attributes in Active Directory using ADSI Edit for any trailing spaces, typos, or any other mistakes.

    Read the article

  • Joining Samba to Active Directory with local user authentication

    - by Ansel Pol
    I apologise that this is somewhat incoherent, but hopefully someone will be able to make enough sense of this to understand what I'm trying to achieve and provide pointers. I have a machine with two network interfaces connected to two different networks (one of which it's providing several other services for, such as DNS), running two separate instances of Samba, one bound to each interface. One of the instances is just a workgroup-style setup using share-level authentication, which is all working fine. The problem is that I'm looking to join the other instance to an MS Active Directory domain (provided by MS Windows Small Business Server 2003) to enable a subset of the domain users to access the shares from Windows machines on the other network. The users who need access from the domain environment have accounts (whose names are all-lowercase versions of their domain usernames) on the machine running Samba, but I'm not sure about how to map the UIDs and everything I've read concerns authenticating accounts on that machine against either AD or another LDAP server. To clarify: I only want the credentials for AD users accessing the non-workgroup Samba instance to be authenticated against AD, not the accounts on the machine running Samba. I hope this is sufficiently clear. EDIT: In addition to being able to access the Samba shares from AD, I do also need to be able to access a share on the domain from the machine running Samba but would still like everything non-Samba-related to authenticate locally.

    Read the article

  • tomcat6 on ubuntu fails when user set to root

    - by J G
    I'm well aware that running tomcat6 is really bad from a security point of view - and opens the box it is running on to all kinds of security risks and attack vectors. That said: When I change the entry in the /etc/init.d/tomcat6 to TOMCAT6_USER=root and then run sudo /etc/init.d/tomcat6 start I get [fail] and nothing is written to the logs under /var/log/tomcat6 and no entry for tomcat6 is created under /var/run How do I diagnose what is going wrong?

    Read the article

  • SBUG --> UK Connected Systems User Group

    - by Michael Stephenson
    Following a recent user group meeting we have decided that the UK SOA/BPM User Group will be renamed to the UK Connected Systems User Group.  The reasons for this are as follows: 1. Other user groups who cover the same topics as us are all called something similar 2. We feel the name change will help to increase user group membership The focus and topics of the user group will remain the same.

    Read the article

< Previous Page | 24 25 26 27 28 29 30 31 32 33 34 35  | Next Page >