Search Results

Search found 24919 results on 997 pages for 'patch update'.

Page 29/997 | < Previous Page | 25 26 27 28 29 30 31 32 33 34 35 36  | Next Page >

  • Why are my Windows 7 updates continuously failing?

    - by Chris C.
    I'm an advanced level user here with an odd issue. I have two Windows Updates that are failing to install, every single time. I'm getting a mysterious "Code 1" error on both updates, an error for which I'm having difficulty finding a solution. The updates in question are: Security Update for Microsoft Visual C++ 2008 Service Pack 1 Redistributable Package (KB2538243) System Update Readiness Tool for Windows 7 for x64-based Systems (KB947821) [May 2011] Because these updates are failing, the Shut Down button in my start menu always has the shield icon next to it, indicating that "new" updates will be installed on shut down. But, of course, they'll fail and when the PC is restarted, the shield icon is still there. When checking the update history and viewing the details of the failed updates, I get the following: Security Update for Microsoft Visual C++ 2008 Service Pack 1 Redistributable Package (KB2538243) Installation date: ?6/?29/?2011 3:00 AM Installation status: Failed Error details: Code 1 Update type: Important A security issue has been identified leading to MFC application vulnerability in DLL planting due to MFC not specifying the full path to system/localization DLLs. You can protect your computer by installing this update from Microsoft. After you install this item, you may have to restart your computer. More information: http://go.microsoft.com/fwlink/?LinkId=216803 System Update Readiness Tool for Windows 7 for x64-based Systems (KB947821) [May 2011] Installation date: ?6/?28/?2011 3:00 AM Installation status: Failed Error details: Code 1 Update type: Important This tool is being offered because an inconsistency was found in the Windows servicing store which may prevent the successful installation of future updates, service packs, and software. This tool checks your computer for such inconsistencies and tries to resolve issues if found. More information: http://support.microsoft.com/kb/947821 About My System I'm running Windows 7 Home Premium x64 Edition. This is a custom PC build and the OS was installed fresh, not an upgrade from a previous version. I've been running this system for about 4 months. Windows Updates aside, the system is usually quite stable. Thanks in advance for your help!

    Read the article

  • Entity Framework Update Entity along with child entities (add/update as necessary)

    - by Jorin
    I have a many-to-many relationship between Issues and Scopes in my EF Context. In ASP.NET MVC, I bring up an Edit form that allows the user to edit a particular Issue. At the bottom of the form, is a list of checkboxes that allow them to select which scopes apply to this issue. When editing an issue, it likely will always have some Scopes associated with it already--these boxes will be checked already. However, the user has the opportunity to check more scopes or remove some of the currently checked scopes. My code looked something like this to save just the Issue: using (var edmx = new MayflyEntities()) { Issue issue = new Issue { IssueID = id, TSColumn = formIssue.TSColumn }; edmx.Issues.Attach(issue); UpdateModel(issue); if (ModelState.IsValid) { //if (edmx.SaveChanges() != 1) throw new Exception("Unknown error. Please try again."); edmx.SaveChanges(); TempData["message"] = string.Format("Issue #{0} successfully modified.", id); } } So, when I try to add in the logic to save the associated scopes, I tried several things, but ultimately, this is what made the most sense to me: using (var edmx = new MayflyEntities()) { Issue issue = new Issue { IssueID = id, TSColumn = formIssue.TSColumn }; edmx.Issues.Attach(issue); UpdateModel(issue); foreach (int scopeID in formIssue.ScopeIDs) { var thisScope = new Scope { ID = scopeID }; edmx.Scopes.Attach(thisScope); thisScope.ProjectID = formIssue.ProjectID; if (issue.Scopes.Contains(thisScope)) { issue.Scopes.Attach(thisScope); //the scope already exists } else { issue.Scopes.Add(thisScope); // the scope needs to be added } } if (ModelState.IsValid) { //if (edmx.SaveChanges() != 1) throw new Exception("Unknown error. Please try again."); edmx.SaveChanges(); TempData["message"] = string.Format("Issue #{0} successfully modified.", id); } } But, unfortunately, that just throws the following exception: An object with the same key already exists in the ObjectStateManager. The ObjectStateManager cannot track multiple objects with the same key. What am I doing wrong?

    Read the article

  • Recent DDE / file open issue with Office 2007 affecting only a few machines, is a Windows Update to blame?

    - by kafka
    All our workstations run Windows 7 Professional 64 bit. It started with one, then another, then another couple of machines having a problem accessing Word files locally and on the network. This doesn't happen on my machine though. Affected users get the error message 'There was a problem sending the command to the program'. I've Googled for solutions, but none of the answers worked. They suggested deleting certain registry keys; unregistering and reregistering the program for DDE; resetting the way that the shell opens .docx programs etc. each to no avail. As it affects local and network shares I believe the problem lies with the clients, and not the server, and I'm starting to suspect that there could have been a recent Windows Update which has caused this. I've tried comparing the updates on my working machine with an affected machine, but I can't immediately see any major differences. Has anyone else recently encountered this problem? What are the best steps to take to further isolate what could be causing this?

    Read the article

  • Why are my Windows 7 updates continuously failing?

    - by Chris C.
    I'm an advanced level user here with an odd issue. I have two Windows Updates that are failing to install, every single time. I'm getting a mysterious "Code 1" error on both updates, an error for which I'm having difficulty finding a solution. The updates in question are: Security Update for Microsoft Visual C++ 2008 Service Pack 1 Redistributable Package (KB2538243) System Update Readiness Tool for Windows 7 for x64-based Systems (KB947821) [May 2011] Because these updates are failing, the Shut Down button in my start menu always has the shield icon next to it, indicating that "new" updates will be installed on shut down. But, of course, they'll fail and when the PC is restarted, the shield icon is still there. When checking the update history and viewing the details of the failed updates, I get the following: Security Update for Microsoft Visual C++ 2008 Service Pack 1 Redistributable Package (KB2538243) Installation date: ?6/?29/?2011 3:00 AM Installation status: Failed Error details: Code 1 Update type: Important A security issue has been identified leading to MFC application vulnerability in DLL planting due to MFC not specifying the full path to system/localization DLLs. You can protect your computer by installing this update from Microsoft. After you install this item, you may have to restart your computer. More information: http://go.microsoft.com/fwlink/?LinkId=216803 and: System Update Readiness Tool for Windows 7 for x64-based Systems (KB947821) [May 2011] Installation date: ?6/?28/?2011 3:00 AM Installation status: Failed Error details: Code 1 Update type: Important This tool is being offered because an inconsistency was found in the Windows servicing store which may prevent the successful installation of future updates, service packs, and software. This tool checks your computer for such inconsistencies and tries to resolve issues if found. More information: http://support.microsoft.com/kb/947821 About My System I'm running Windows 7 Home Premium 64-bit. This is a custom PC build and the OS was installed fresh, not an upgrade from a previous version. I've been running this system for about four months. Windows Updates aside, the system is usually quite stable.

    Read the article

  • Do I need to update some of my Debian Squeeze software?

    - by stan31337
    I have installed Debian 6, and LAMP stack from squeeze repository (default). After upgrading Apache 2.2.16 from unstable repository to 2.2.22, thanks to this post - how to upgrade already installed apache2 on debian (lenny) I'm thinking to upgrade all other software packages that I've previously installd from squeeze repository. Should I upgrade them to the ones from unstable repository? Should I upgrade all of them or just selected ones? Here's the list: * arno-iptables-firewall 1.9.2.k-4 >> 2.0.1.c-1 * bind9 1:9.7.3.dfsg-1~squeeze6 >> 1:9.8.1.dfsg.P1-4.2 * php-apc 3.1.3p1-2 >> 3.1.13-1 * fail2ban 0.8.4-3+squeeze1 >> 0.8.6-3 * exim4 4.72-6+squeeze2 >> 4.80-4 * altermime 0.3.10-4 >> 0.3.10-7 * rrdtool 1.4.3-1 >> 1.4.7-2 * vsftpd 2.3.2-3+squeeze2 >> 3.0.0-4 Also I would like to ask how to upgrade 5.3.3 5.3.16, unstable repository has 5.4.x versions only, I don't think I'm ready to move from 5.3 to 5.4 yet. Actually I'm a newbie in Linux, and after Windows experience I have a paranoidal idea to update software to the latest release. I'd be glad for any suggestions and recommendations! Thank you very much!

    Read the article

  • How to update many databases when we update any tablw

    - by Lalit Kandpal
    I am creating a C# window application which is based on a medical inventory.In this application I have mainly three forms as PurchaseDetail,SalesDetail,and StockDetail. Now I want a functionality in which if i insert or modify the records in PurchaseDetail,or SalesDetail the Data in the StockDetail should also be modified.(for example if i insert some quantity of medicines in PurchaseDetail then Quantity In StockDetail should also modified and same as for SalesDetail ) Columns in PurchaseDetail: Id(Primary Key and auto increment int),BatchNumber,MedicineName,ManufacturingDate,ExpiryDate,Rate,MRP,Tax,Discount,Quantity Columns in SalesDetail: Id(PrimaryKey and auto increment int),BillNumber,CustomerName,BatchNumber,Quantity,Rate,SalesDate Columns in StockDetail: Id(Primary Key and auto increment int),ProductId,ProductName,OpeningStock,ClosingStock,PurchaseQty,DispenseQty,PurchaseReturn,DispenseReturn Please Help me.

    Read the article

  • EMERGENCY! Update Statement for critical mysql production database now running for 18 hours, need help.

    - by Tim
    We have a table with 500 million rows. Unfortunately, one of the columns was int(11), which is a signed int, and it was an incrementing value that just rolled over the 2.1 billion magic number. This immediately caused downtime for about 10.000 users. We discussed many solutions, and decided that we could just roll back this value safely, by say, a billion. But we had to roll it back for every row. Here is what we did: update Table1 Set MessageId = case when MessageId < 1073741824 then 0 else MessageId - 1073741824 end; I tested this on a table with 10 million rows and it took 11 minutes. So I assumed the larger table would take 550 minutes, or 9 hours. This was going to be our biggest downtime in 3 years. (We're a startup). It's now going on 18 hours. What should we do? Please don't say what we should have done. I think we should have updated a few million rows at a time. Is there a way we can see progress? Could Mysql have hung? Using mysql 5.0.22. Thanks!

    Read the article

  • Are VMWare ESXi 5 patches cumulative?

    - by ewwhite
    It seems basic, but there's confusion about the patching strategy needed to manually update standalone VMWare ESXi hosts. The VMWare vSphere blog attempts to explain this, but it's still not clear. From the blog: Say Patch01 includes updates for the following VIBs: "esxi-base", "driver10" and "driver 44". And then later Patch02 comes out with updates to "esxi-base", "driver20" and "driver 44". P2 is cumulative in that the "esxi-base" and "driver44" VIBs will include the updates in Patch01. However, it's important to note that Patch02 not include the "driver 10" VIB as that module was not updated. Many of my ESXi installations are standalone and do not make use of Update Manager. It is possible to update an individual host using the patches make available through the VMWare patch download portal. The process is quite simple, and that part makes sense. The bigger issue is determining what to actually download and install. In my case, I have a good number of HP-specific ESXi builds that incorporate sensors and management for HP ProLiant hardware. Let's say that those servers start at ESXi build #474610 from 9/2011. Looking at the patch portal screenshot below, there is a patch for ESXi update01, build #623860. There are also patches for builds #653509 and #702118. Coming from the old version of ESXi, what is the proper approach to bring the system fully up-to-date? Which patches are cumulative and which need to be applied sequentially? Perhaps the download size is the confusing factor, but is installing the newest build the right approach, or do I need to step back and patch incrementally?

    Read the article

  • How to schedule time-of-day upgrades

    - by Richard
    Hello, I'm responsible for about 30 Ubuntu computers at a private K-8 school. We have only a 3Mbps internet connection serving the entire campus, and I would like to ensure that updates are done in the middle of the night - so that daytime tasks are not slowed down. I'm using Ubuntu 10.04, and have set all computers to download and install security updates via the update manager. I have also installed cron-apt, and modified the config file to stagger the start times of the upgrades from about 10pm to 4am local time. HOWEVER - this morning I arrived at the school at 7:30am and all the computers were busy downloading a large security based update. Needless to say, all internet activity was slowed to a crawl (for the next 2 hours), and the computer users were very very upset. This was the event I'm trying so hard to prevent. It seems that my scheme to ensure middle of the night downloads failed, and I'm not sure why. I've also tried some schemes using unattended-upgrades & crontab, but there always seemed to be something scheduling upgrades to occur in addition to the ones I try to force at middle of the night. Is there a sure fire way to absolutely positively guarantee that updates will occur only at one specific time? It would be nice if the update manager just had a drop down menu to specify a designated time. Thanks in advance for any help you can give me.

    Read the article

  • Distribution upgrade (12.04 -> 14.04 LTS) halted while unpacking/installing packages

    - by Bob Sully
    As the title states...it just stopped unpacking/installing. "Preparing to unpack .../lirc_0.9.0-0ubuntu5_amd64.deb ..." then stopped in its tracks. Everything else is still running. The update manager process is still alive; if I hit ctrl-c, it gives me the warning message about leaving the system in a broken state. Also, if I run top, there is a process called "trusty" which is still running. I have NOT killed either process. lsb_release -a gives: LSB Version: core-2.0-amd64:core-2.0-noarch:core-3.0-amd64:core-3.0-noarch:core-3.1-amd64:core-3.1-noarch:core-3.2-amd64:core-3.2-noarch:core-4.0-amd64:core-4.0-noarch Distributor ID: Ubuntu Description: Ubuntu 14.04.1 LTS Release: 14.04 Codename: trusty I assume that if I try to restart update-manager, I won't be offered the option to upgrade again. Anyone have a way I can get the update-manager/dist-upgrade process to simply finish the upgrade? Thanks!

    Read the article

  • Part 7: EBS Modifications and Flagged Files in R12

    - by volker.eckardt(at)oracle.com
    Let me, based on my previous blog, explain the procedure of flagged files a bit better and facilitate the same with screenshots. Flagged files is a concept within the Oracle eBusiness Suite (EBS) release 12, where you flag a standard deployment file, let’s say a Forms file, a Package or a Java class file. When you run the patch analyse, the list of flagged files will be checked and in case one of these files gets patched, the analyse report will tell you. Note: This functionality is also available in release 11, here it is implemented and known as “applcust.txt”. You can flag as many files as you want, in whatever relationship they are with your customizations. In addition to the flag itself you can add a comment. You should use this comment to point to your customization reference (here XXAR_RPT_066 or XXAP_CUST_030). Consider the following two cases: You have created your own report, based on a standard report. In this case you will flag the report file itself, and the key views used. When a patch updates one of these files, you will be informed and can initiate a proper review and testing. (ex.: first line for ARXCTA.rdf) You have created an extensive personalization and because it is business critical you like to be informed if the page definition gets updated. In this case you register the PG.xml file as flagged file. (ex.: second line below for CreateExtBankAcctPG.xml) The menu path to register flagged files is the following: (R) System Administrator > (M) Oracle Applications Manager > Site Map > Maintenance > Register Flagged Files     Your DBA should now run the Patch Analyse every time he is going to apply a new patch. (R) System Administrator > (M) Oracle Applications Manager > Patch Wizard > Task “Recommend/Analyze Patches” The screenshot above shows the impact summary. For this blog entry the number “2” titled “Flagged Files Changed“ is in our focus. When you click the “2” you will get a similar screen like the first in this blog, showing you exactly the files which will get patched if you continue and apply this patch in this environment right now. Note: It is also shown that just 20% of all patch files will get applied. This situation might be different in case your environments are on a different patch level. For sure also the customization impact might then be different. The flagging step can be done directly in the Oracle Applications Manager.  Our developers are responsible for. To transport such a flag+comment we use a FNDLOAD script. It is suggested to put the flagged files data file directly into your CEMLI patch. Herewith the flagged files registration will be executed right at the same time when the patch gets applied. Process Steps: Developer: Builds CEMLI Reviews code and identifies key standard objects referenced Determines standard object files and flags them Creates FNDLOAD file and adds the same to the CEMLI patch DBA: Executes for every new Oracle standard patch the patch analyse in a representative environment Checks and retrieves the flagged files and comments Sends flagged file list back to development team for analyse / retest Developer: Analyses / Updates / Retests effected CEMLIs Prerequisite: The patch analyse has to be executed in an environment where flagged files have been registered. (If you run the patch analyse in a vanilla or outdated environment (compared to your PROD), the analyse will not be so helpful!) When to start with Flagged files? Start right now utilizing this feature. It is an invest to improve the production stability and fulfil your SLA!   Summary Flagged Files is a very helpful EBS R12 technique when analysing patches. Implement a procedure within your development process to maintain such flags. Let the DBA run the patch analyse in an environment with a similar patch and customization level as your current production.   Related Links: EBS Patching Procedures - Chapter 2-13 - Registered Flagged Files

    Read the article

  • Cumulative Update 8 for SQL Server 2008 R2 is available

    - by AaronBertrand
    Today the SQL Server Release Services team has published Cumulative Update #8 for SQL Server 2008 R2. http://support.microsoft.com/kb/2534352 The build number is 10.50.1797, there are 14 fixes showing on the KB article, and this update includes the security update from last week's Patch Tuesday . Important No, this patch is not for SQL Server 2008, and no, it is not applicable if you've already installed the CTP of Service Pack 1 for SQL Server 2008 R2 (10.50.2418 or 10.50.2425). Please check @@VERSION...(read more)

    Read the article

  • NSIS patching (multiple patches in one file)

    - by Owen
    I'm able to generate patch files from one version to another using NSIS' Vpatch. Let's say I have mydll.dll version 1, and I have a patch to update it to version 2. Then I have a new version again, thus I generate another patch to update it to version 3. What bothers me though is, what if user cancels updating to version 2 and so forth. Then my latest version let's say is version 20. User decides to update to version 20. Is there a way to generate a patch that's like accumulative in nature? whereas user can jump from version any old version to the newest version (i.e ver 3 to ver 20) without passing through the versions in between? I've read this line in vpatch's documentation --- "if you want to be able to upgrade version 1 and 2 to version 3, you can put a 1 3 and 2 3 patch in one file." But how do I that? What if I alread have like 30 versions. Does that mean I have to create a patch whose arguments are old files(versions 1-29) and new file(version20)? Any help would be appreciated. Thanks...

    Read the article

  • How to set the delay between update queries in Mysql so that every query get executed succesfully?

    - by OM The Eternity
    Hi All I have to the Update query mulitple times for different parameters using for loop in my PHP Script, now the problem Is Whenever I do it, only my last query get executed, all the previous queries seems to be skipped. the loop goes like this: foreach($cntrlflagset as $cntrlordoc => $cntrlorflag){ for($t=0;$t<count($cntrlorflag);$t++){ $userlvl = "controller"; $docflag = 1; $postfix = "created"; $createdoc->updatedocseeflags($cntrlorflag[$t],$docflag,$cntrlordoc,$postfix,$userlvl); $docflag = 2; $postfix = "midlvl"; $createdoc->updatedocseeflags($cntrlorflag[$t],$docflag,$cntrlordoc,$postfix,$userlvl); } } Here, the called function $createdoc-updatedocseeflags($cntrlorflag[$t],$docflag,$cntrlordoc,$postfix,$userlvl); Contains the Update query: $query = "UPDATE tbl_docuserstatus SET"; //if($flag != ""){ $query .= " docseeflag_".$postfix." = '".$flag."'"; //} $query .= " WHERE doc_id = '".$doc_id."' AND user_id = '".$user_id."'"; if($userlvl == "midlvl"){ $query .= " AND doc_midlvluser = '1'"; }elseif($userlvl == "finallvl"){ $query .= " AND doc_finallvluser = '1'"; }elseif($userlvl == "creator"){ $query .= " AND doc_creator = '1'"; }elseif($userlvl == "controller"){ $query .= " AND doc_controller = '1'"; }elseif($docarchive == 1){ $query .= " AND doc_controller = '1'"; } So could some one tell me, How to set the delay between update queries in Mysql so that every query get executed succesfully? Thanks In Advance

    Read the article

  • Getting a list of patches in an HPSA patch policy

    - by asm
    I'm trying to get a list of patches contained in a Patch Policy in HPSA -- I can get what I need via the Twister web interface (under PatchPolicy.getPatches(), give it an ID, and it happily returns a list of patches contained.) -- I'm having a hard time getting this to work via the Pytwist interface, though... I haven't used the Pytwist interface for much besides some very basic Device manipulation, and Python is.. not my forte. I create the TwistServer object, then a PatchPolicy object from that (which I think is working..), but can't figure out how/where to call the getPatches() method from in Python-land. If there's a way to dig this out of the database itself, that would work, too, but I can't seem to find much in there along these lines besides the vendor-recommended patching stuff, and we use custom policies.

    Read the article

  • Patch msp into msi package

    - by Kvad
    The latest update of Windows Live Messenger is an msp added to the package. I want to patch a msp into an msi. Reference download http://wl.dlservice.microsoft.com/download/8/3/D/83D75746-DF04-45E9-8374-BD31B9419128/en/wlsetup-all.exe I extract all msi and msps from this. (To get the msp and msi's I did the following Use resource hacker to open up wlsetup-all.exe In the left hand tree browse to PACKAGE Right click PACKAGE, save PACKAGE resources Save to a new temp folder Eg. D:\temp\package.rc This will output a whole lot of .bin files These are just cab files so we need to do a mass rename “ren *.bin *.cab” Once done select all cab files and extract to a new sub folder \extracted In \extracted you will see all the msi, msp and 7z files you need) I try to apply the msp directly with no result msiexec /p messenger.msp /a messenger.msi I also try doing a admin install with nothing being extracted.

    Read the article

  • Safe use of Update-FormatData?

    - by Steve B
    In a custom PowerShell module, I have at the top of my module definition this code: Update-FormatData -AppendPath (Join-Path $psscriptroot "*.ps1xml") This is working fine as all .ps1xml files are loaded. However, the module is sometimes loaded using Import-Module MyModule -Force (actually, this is in the install script of the module). In this case, the call to Update-FormatData fails with this error : Update-FormatData : There were errors in loading the format data file: Microsoft.PowerShell, c:\pathto\myfile.Types.ext.ps1xml : File skipped because it was already present from "Microsoft.PowerShell". At line:1 char:18 + Update-FormatData <<<< -AppendPath "c:\pathto\myfile.Types.ext.ps1xml" + CategoryInfo : InvalidOperation: (:) [Update-FormatData], RuntimeException + FullyQualifiedErrorId : FormatXmlUpateException,Microsoft.PowerShell.Commands.UpdateFormatDataCommand Is there a way to safely call this command? I know I can call Update-FormatData with no parameters, and it will update any known .ps1xml file, but this would work only if the file has already been loaded. Can I list somewhere the loaded format data files? Here is a bit of background: I'm building a custom module that is installed using a script. The install script looks like : [CmdletBinding(SupportsShouldProcess=$true,ConfirmImpact="High")] param() process { $target = Join-Path $PSHOME "Modules\MyModule" if ($pscmdlet.ShouldProcess("$target","Deploying MyModule module")) { if(!(Test-Path $target)) { new-Item -ItemType Directory -Path $target | Out-Null } get-ChildItem -Path (Split-Path ((Get-Variable MyInvocation -Scope 0).Value).MyCommand.Path) | copy-Item -Destination $target -Force Write-Host -ForegroundColorWhite @" The module has been installed. You can import it using : Import-Module MyModule Or you can add it in your profile ($profile) "@ Write-Warning "To refresh any open PowerShell session, you should run ""Import-Module MyModule -Force"" to reload the module" Import-Module MyModule -Force Write-Warning "This session has been refreshed." } } MyModule defines, as first statement, this line : Update-FormatData -AppendPath (Join-Path $psscriptroot "*.ps1xml") As I updated my $profile to always load this module, the Update-Path command has been called when I run the install script. In the install script, I force import the module, which be fire again the module, and then, the Update-Path call

    Read the article

  • TortoiseSVN : Good 'patch file' viewer ?

    - by mishal153
    Hi, The default patch file viewer is messy (ie. no side by side diff view etc). I tried setting the path of beyondCompare exe in "Settings-Unified Diff Viewer-custom", but beyond compare also behaves same as default diff tool. Is there a way to atleast allow side by side diff in patch files ? If so, what is the method ? My aim is to allow emailing of changes so that they can be reviewed before I commit them :) Mishal

    Read the article

  • GIT <> SVN interchangeable patch-files

    - by pagid
    Hi, I maintain a subproject which is running on the project's SVN server. I personally prefer to work with Git - the problem is that the entire community uses SVN, expects RFCs with a SVN compatible patch-file and people are familiar with SVN and send bugfixes agains that SVN repository too. Therefore my only problem is to create patch files which are compatible with Git and SVN at the same time. Is there some kind of smart shell-script or even a buildin feature I'm not aware of? Cheers

    Read the article

  • Applying a patch from java.net

    - by user354414
    I have a problem with Jaxb enumerations that is related to this bug https://jaxb.dev.java.net/issues/show_bug.cgi?id=708 A patch has been supplied to the issue that can resolve the problem. How can I apply this patch to resolve my problem

    Read the article

  • How to trouble 9-patch image in android

    - by michael
    Hi, I have an ImageView in my layout xml file. I set the width to wrap_content and height to fill_parent. In hierarchy viewer, the width is 2 px and height is 120 px. But when i see it on device, my 9-patch image for the image view does not stretch to 120 px. Can you please tell me how can I trouble shoot this 9 patch image does not stretch error? Thank you.

    Read the article

  • What is the problem with the logic in my UPDATE statement?

    - by Stefan Åstrand
    Hello, I would appreciate some help with an UPDATE statement. I want to update tblOrderHead with the content from tblCustomer where the intDocumentNo corresponds to the parameter @intDocumentNo. But when I run the my statement, the order table is only updated with the content from the first row of the customer table. What is the problem with my logic? I use Microsoft SQL Server. Thanks, Stefan UPDATE dbo.tblOrderHead SET dbo.tblOrderHead.intCustomerNo = @intCustomerNo , dbo.tblOrderHead.intPaymentCode = dbo.tblCustomer.intPaymentCode, dbo.tblOrderHead.txtDeliveryCode = dbo.tblCustomer.txtDeliveryCode, dbo.tblOrderHead.txtRegionCode = dbo.tblCustomer.txtRegionCode, dbo.tblOrderHead.txtCurrencyCode = dbo.tblCustomer.txtCurrencyCode, dbo.tblOrderHead.txtLanguageCode = dbo.tblCustomer.txtLanguageCode FROM dbo.tblOrderHead INNER JOIN dbo.tblCustomer ON dbo.tblOrderHead.intOrderNo = @intDocumentNo

    Read the article

  • Is there a way to optimize this update query?

    - by SchlaWiener
    I have a master table called "parent" and a related table called "childs" Now I run a query against the master table to update some values with the sum from the child table like this. UPDATE master m SET quantity1 = (SELECT SUM(quantity1) FROM childs c WHERE c.master_id = m.id), quantity2 = (SELECT SUM(quantity2) FROM childs c WHERE c.master_id = m.id), count = (SELECT COUNT(*) FROM childs c WHERE c.master_id = m.id) WHERE master_id = 666; Which works as expected but is not a good style because I basically make multiple SELECT querys on the same result. Is there a way to optimize that? (Making a query first and storing the values is not an option. I tried this: UPDATE master m SET (quantity1, quantity2, count) = ( SELECT SUM(quantity1), SUM(quantity2), COUNT(*) FROM childs c WHERE c.master_id = m.id ) WHERE master_id = 666; but that doesn't work.

    Read the article

< Previous Page | 25 26 27 28 29 30 31 32 33 34 35 36  | Next Page >