  • Openfire on EC2 with Jingle

    - by Bjorn Roche
    I would like to run Openfire (or another XMPP server) on EC2. At the moment this is just for testing, so easy setup and configuration are important, as is low cost. At some point, however, if things go well, it will be important to scale this. Ideally, it would be nice to not have to switch software when the scaling happens, but if a switch needs to happen later it certainly can. My requirements are: basic XMPP services, including muc and pubsub. Logins controlled from an external API. Preferably, when a user attempts to connect, the XMPP server checks with the api to see if their username and password are correct, but I can also have the API keep the XMPP server up to date on new users, deleted users, pasword changes and so on. I see Openfire has a "user service" API. Not ideal, but it looks workable. Jingle, including relay and STUN. It's not at all clear to me if the Jingle Nodes plugin takes care of this. I'm a bit confused about what's required to set this up, and I'd rather know in advance than be confused along the way :). eg It seems like STUN servers require more than one IP address. Can Openfire do all this for me, including stun and media relay on a single machine? Is this hard to configure on EC2 with Openfire? What are the basic steps? Would this be easier with something else like, say Tigase? What about database? Should I use amazon's database service, or run a db on the same machine? Would the server be compatible with a service like http://www.siteuptime.com/ Thanks!

    Read the article

  • MS SQL Server 2005 Express rebuild master DB problem

    - by PaN1C_Showt1Me
    Hi ! There has been a power loss on our server and i cannot start the SQL service because the master DB is corrupted (as the log states). I found many articles recommending running the setup.exe with optional parameters: This is what I did: I've downloaded SQLEXPR32.EXE from MS page and ran it The first problem was, that it extracted all the setup files and started the default installation procedure. (which was unuseful for me as I need those params). If I canceled it, all the extracted files disappeared. That's why I decided to copy the extracted files somewhere and than cancel the default installation. Now I'm trying to run the setup.exe from the extraction: setup.exe /qb INSTANCENAME=MSSQLSERVER REINSTALL=SQL_Engine REBUILDDATABASE=1 SAPWD=xxxxx it asks me if I want to rewrite the system db, which is what I need, but then while installing I get this error: *An installation package for the product Microsoft SQL Server 2005 Express Edition cannot be found. Try the installation again using a valid copy of the installation package 'SqlRun_SQL.msi'* Then it tries to install something and it states: cannot install because the same instance name already exists. But I don't want to install a new instance .. Any idea how to solve this, please? Thank you in advance !

    Read the article

  • Real-time local backup with versioning on Windows 7/8

    - by Borda
    I'm looking for a reliable backup solution on Windows, something with a feature set similar to Yadis. I've been using CrashPlan for 2 months, but their software lost more than 1TB of my data, that's why I'm looking for alternatives. Requirements: Real-time folder-to-folder backup: I don't need online features, I want to use this to duplicate my files between my local disks. Versioning support: Should be able to choose how many versions to keep of the files. Plain backup: I'd like to be able to open the backup without special software. No proprietary file format. External disk support: Shouldn't have any problem using external disks, at least on the source side. Backup every file, even locked/system files. (Yadis fails this one) Should start automatically, and have a comfortable GUI. Should use actively maintained and/or popular software. I don't want to use discontinued products. Optional requirements: Low RAM usage I'm not really comfortable with something that eats 1GB of my RAM. Compression support Preferably ZIP, but I'm not picky about this. Any ordinary everyday format is acceptable. Freeware or Open Source Preferred, but not necessary. I can do a one-time payment within reasonable bounds. (preferably under $100) I only need Windows support, but if it works on Linux, that's a plus. I've already searched and tried lots of software, most of them failed at the plain backup, the versioning or the locked file backup requirements.

    Read the article

  • Installing VirtualBox on BackTrack 5

    - by m0skit0
    I'm getting this error when running VirtualBox's installation script: $ sudo ~/Downloads/VirtualBox-4.1.14-77440-Linux_x86.run Verifying archive integrity... All good. Uncompressing VirtualBox for Linux installation........... VirtualBox Version 4.1.14 r77440 (2012-04-12T16:20:44Z) installer Removing previous installation of VirtualBox 4.1.14 r77440 from /opt/VirtualBox Installing VirtualBox to /opt/VirtualBox tar: Record size = 8 blocks Python found: python, installing bindings... Building the VirtualBox kernel modules Error! Bad return status for module build on kernel: 3.2.6 (i686) Consult the make.log in the build directory /var/lib/dkms/vboxhost/4.1.14/build/ for more information. ERROR: binary package for vboxhost: 4.1.14 not found Here's the log: $ cat /var/lib/dkms/vboxhost/4.1.14/build/make.log DKMS make.log for vboxhost-4.1.14 for kernel 3.2.6 (i686) Sun May 13 14:32:52 CEST 2012 make: Entering directory `/usr/src/linux-headers-3.2.6' /usr/src/linux-headers-3.2.6/arch/x86/Makefile:39: /usr/src/linux-headers-3.2.6/arch/x86/Makefile_32.cpu: No such file or directory make: *** No rule to make target `/usr/src/linux-headers-3.2.6/arch/x86/Makefile_32.cpu'. Stop. make: Leaving directory `/usr/src/linux-headers-3.2.6' /usr/src/linux-headers-3.2.6/arch/x86/ directory: $ ls /usr/src/linux-headers-3.2.6/arch/x86/ Kconfig Makefile ia32 lguest mm pci tools video Kconfig.cpu boot kernel lib net platform um xen Kconfig.debug crypto kvm math-emu oprofile power vdso Makefile references on "cpu" $ cat /usr/src/linux-headers-3.2.6/arch/x86/Makefile | grep cpu include $(srctree)/arch/x86/Makefile_32.cpu # FIXME - should be integrated in Makefile.cpu (Makefile_32.cpu) Before upgrading to 3.X I didn't have this problem, the script would install VB correctly. Any ideas on what might be causing this? Thanks in advance!

    Read the article

  • Apache Consuming Resources

    - by Chris Edwards
    Our web server suddenly has been giving us load issues. After I restart Apache the load stays low for a few hours up to a day or so then its back up to around 3.0 until I restart Apache again. Any suggestions on tracking down what is causing this? Thanks! Chris Edwards top - 20:15:05 up 19 days, 10:59, 1 user, load average: 2.11, 2.17, 2.47 Tasks: 532 total, 6 running, 525 sleeping, 0 stopped, 1 zombie Cpu(s): 11.5%us, 0.4%sy, 0.0%ni, 88.1%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 32842656k total, 13185872k used, 19656784k free, 6143740k buffers Swap: 1048568k total, 0k used, 1048568k free, 3515252k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 19089 apache 20 0 1912m 1.5g 6584 R 99.6 4.9 71:01.53 /usr/sbin/httpd 21136 apache 20 0 392m 55m 5736 R 95.0 0.2 0:03.45 /usr/sbin/httpd 21139 apache 20 0 374m 38m 5808 S 40.5 0.1 0:04.91 /usr/sbin/httpd 21124 apache 20 0 389m 51m 5948 R 38.9 0.2 0:03.15 /usr/sbin/httpd 21111 apache 20 0 371m 35m 5964 S 18.8 0.1 0:01.22 /usr/sbin/httpd 21127 apache 20 0 375m 39m 5832 S 17.8 0.1 0:01.66 /usr/sbin/httpd 21128 apache 20 0 374m 38m 5792 S 16.2 0.1 0:01.56 /usr/sbin/httpd 21110 apache 20 0 374m 38m 5848 S 15.9 0.1 0:01.02 /usr/sbin/httpd 21113 apache 20 0 374m 38m 5836 S 15.9 0.1 0:02.16 /usr/sbin/httpd 21077 apache 20 0 379m 43m 6408 S 11.0 0.1 0:07.22 /usr/sbin/httpd 21101 apache 20 0 384m 49m 6988 R 5.8 0.2 0:04.47 /usr/sbin/httpd 21112 apache 20 0 374m 38m 5956 R 2.6 0.1 0:01.61 /usr/sbin/httpd

    Read the article

  • Monitor connected with WiDi just shows a black screen

    - by Pops
    I have a Dell XPS 18 and want to use an external monitor with it. The monitor has VGA and DVI-D inputs. The XPS 18 has no video output ports, but it does support Intel WiDi. I have a Netgear P2TV2000 WiDi receiver, but it only has composite and HDMI outputs. I'm connecting the receiver to the monitor with an HDMI cable and an HDMI/DVI-D adapter. So, in short, the video path is: Computer → WiDi → WiDi receiver → HDMI cable → HDMI/DVI-D adapter → Monitor After setting all this up, I can't get anything to display on the monitor. At the moment I power the monitor on, I can see my desktop for a brief fraction of a second, and then everything goes black. All of the relevant drivers have been updated to the latest versions. When I use a different WiDi-enabled computer to connect to the same monitor, everything works fine. When I use the original computer and receiver to connect to a TV, everything works fine. It's only when I connect the original computer to the monitor I want to use that the connection fails. What could be going wrong here, and how can I get the video to work consistently?

    Read the article

  • Skip all warning prompts on ACPI shutdown?

    - by N Rahl
    When I issue an ACPI shutdown command to a Windows XP guest machine from the host VM server, I want Windows to shutdown. The problem is, Windows always wants to ask some question or another, rather than just shutting down. I need shutdown to be reliable, no matter what is running or going on, so I can automate shutdowns from the host machine. But I want it to be as graceful as possible, rather than just pulling the plug. Some problems: If a user is logged in, ACPI shutdown causes a box to appear that says, "are you sure you want to shutdown while other users are logged in"? And this prevents shutdown until someone connects to the machine and clicks "yes". In this case, it should try its best to gracefully log out all users, using force if necessary, and then shutdown without promoting. Busy or non-responding programs or programs asking to save data can prevent Windows from shutting down until a user answers a prompt. This should attempt to save data, wait maybe 30 seconds for non-responding programs, but should get aggressive with stubborn programs. "nope, time's up! 3,2,1, Goodbye!" Is there a registry setting that I can change from: ACPI_Shutdown: "Shut down if Windows feels like it" to ACPI_Shutdown: "Just do it. Kill programs, bump users, try to be graceful about it, but when I come back, I expect you to be off." This should respond to the ACPI shutdown command, and not be a script on windows, unless that script is triggered by the ACPI power button. I'm hoping this can be changed with registry options.

    Read the article

  • Windows 8 auto-hibernate from sleep not working on Retina MacBook Pro

    - by frenchglen
    I have a similar question to this one. Only my context is the 15" Retina MacBook Pro - and Windows 8. I have just the original Mac OS X Mountain Lion on there, then Windows 8 via Bootcamp. no rEFIt installed. (I just press ALT every time I restart windows, actually as a security measure to stop tech-unsavvy thugs, who, if the laptop is stolen, think it's only a mac and don't discover my Windows as quickly as they would've, and by that time I remotely activate various anti-theft mac apps and nab them that way). SO: like the related question asks, why isn't it behaving like it should? The Windows 7 FAQ states: Will sleep eventually drain my laptop battery? If your laptop battery charge gets critically low while the computer is asleep, Windows automatically puts the laptop into hibernation mode. But this is just not happening - on my rMBP Windows 8. It seems EVERY time I set the laptop to sleep (when it reaches 10%), then arriving home and plugging it in and hoping to simply resume my work, it does NOT save the session to disk and I lose ALL my work. Who's fault is it? Win 8's (a bug, grr)? Or Apple's EFI system (maybe fixable via editing EFI options/do I have to install refit to make it work perhaps?) Or maybe changing windows power options can somehow fix the problem? Thanks for your help.

    Read the article

  • How to repair a damage transaction log file for Exchange 2003

    - by Markus Larsson
    Hi! Yesterday we had a power failure and the UPS did not work (it has worked perfect before). Everything seem to be ok when I started all the servers again except of the mail, when I try to mount the store I get the following message: “The database files in this store are corrupted” Server: Exchange 2003 running on a Small Business Server Latest full backup: one week old Backup program: Backup Exec 9.0 This is what I have done: 1. Copy every file in the MDBDATA folder (edb, stm, log) 2. Run Eseutil /d for priv1.edb 3. Run Eseutil /p for priv1.edb (took seven hours) 4. Run Isintig –fix –test alltests, now it breaks down. Isintig fails with the following error: Isinteg cannot initiate verification process. Please review the log file for more information. The problem is that there is no log file created. 5. Giving up on this route I decide to do a restore from the backup, it fails with the following error: Unable to read the header of logfile E00.log. Error -501, and the error: Information Store (5976) Callback function call ErrESECBRestoreComplete ended with error 0xC80001F5 The log file is damaged. My conclusion is that E00.log is damage, so how can I repair it so that I can restore the database? Or should I give up and try some other route?

    Read the article

  • Apple Service Diagnostic application on USB key?

    - by Matt 'Trouble' Esse
    I found the following in a text file, and I would like to use the Apple Service Diagnostic Application from a bootable USB key but I cannot find where to download it or set it up? Also is this free software or does it require a separate licence? It sounds like it would be a useful tool for diagnosing Mac problems. The Apple Service Diagnostic application is designed to run both EFI and Mac OS X tests from an external USB hard drive. Apple Service Diagnostic (EFI) runs low-level tests of the hardware directly and does not require Mac OS X, while Apple Service Diagnostic (OS) uses Mac OS X to run tests. Booting and Using the Apple Service Diagnostic Application - Before using Apple Service Diagnostic, disconnect any Ethernet network, USB, and audio cables. - With the USB hard drive containing ASD 3S123 plugged into a USB port, restart the computer and hold down the option key as the computer boots up into the Startup Manager. To run ASD (EFI) select the "ASD EFI 3S123" drive icon and press return or select it with a mouse click. To run ASD (OS) select the "ASD OS 3S123" drive icon and press return or select it with a mouse click. ASD (EFI) will load in 20-30 seconds; ASD (OS) will load in 2-3 minutes. - After running ASD (OS) or ASD (EFI), press the Restart button to restart the computer back into the normal startup volume, or hold down the option key to get back to the Startup Manager. ASD is no longer delivered as an image to be restored onto a DVD. ASD 3S117 and newer versions requires installation onto an external USB hard drive. For more information, please refer to the document "Installing ASD on a USB hard drive".

    Read the article

  • How do I switch java versions to an earlier version in Fedora 17?

    - by JHutson456
    I just installed Fedora 17. I'm setting up the Android Build Environment and need Java. I downloaded and installed jdk-6u32-linux-amd64.rpm I ran java -version and it spit out the correct version. Well a day or two later i tried my first compile in Fedora 17 and it complained about java and failed. I ran java -version again and low and behold it spits out $ java -version java version "1.7.0_03-icedtea" OpenJDK Runtime Environment (fedora-2.1.fc17.7-x86_64) OpenJDK 64-Bit Server VM (build 22.0-b10, mixed mode) I'm stumped. I mean, i've run the update/upgrade commands since i installed but i didn't think that updated full version revisions... So, I ran alternatives --config java and that only gave me the java 1.7 version. While digging around more I discovered that the recommended version of Java for the build environment is jdk-6u27-linux-x64-rpm.bin so I downloaded that from here: Oracle Download When I ran: sudo sh jdk-6u27-linux-x64-rpm.bin it returned: Unpacking... Checksumming... Extracting... UnZipSFX 5.50 of 17 February 2002, by Info-ZIP ([email protected]). inflating: jdk-6u27-linux-amd64.rpm inflating: sun-javadb-common-10.6.2-1.1.i386.rpm inflating: sun-javadb-core-10.6.2-1.1.i386.rpm inflating: sun-javadb-client-10.6.2-1.1.i386.rpm inflating: sun-javadb-demo-10.6.2-1.1.i386.rpm inflating: sun-javadb-docs-10.6.2-1.1.i386.rpm inflating: sun-javadb-javadoc-10.6.2-1.1.i386.rpm Preparing... ########################################### [100%] package jdk-2000:1.6.0_32-fcs.x86_64 (which is newer than jdk-2000:1.6.0_27-fcs.x86_64) is already installed Done. so now I'm confused. I ran: alternatives --config java again but it's still only returning 1.7 so I don't know what to do.I want to end up with 6u27 as the installed and functional version of the JDK. Thank you.

    Read the article

  • Software distribution from web server to client using PHP/FTP

    - by Jenolan
    I develop and maintain a number of add-ons and utilities for various widget (mainly aMember) which generally means I need to install php based codes onto other people's systems. Whilst I have a VPS and have access to rsync and all sorts of yummy tools most of the people I deal with have a basic ftp access and that's all folks. To upload from my local system is also a problem as I am satellite based (two-way) so it is fairly slow and expensive and in any case the files are already on my server. So there is no rsync, fxp, ssh and I can't really install anything as it is obviously not my system, they would be justifiably miffed if I started installing file managers or other things onto their sites. What I have been trying to find is a utility that I can run on my server from the web, preferably php based, that will be like a file manager but a bit different. Two panels. LH-Side the local server .. pretty much like a standard FM application RH-Side ability to login via FTP to the clients system Then I can fiddle as required. The closest thing I have found is net2ftp but it doesn't have the gui interface, at the moment I simply ssh into my server power up ncftp and run that way, but something easier to use would be mucho niceness. Thanks in advance! Larry

    Read the article

  • There's a stray current flowing from my monitor through the VGA cable to the PC. Is this safe?

    - by EApubs
    I have two monitors in my machine. One is an old LCS samsung monitor. Recently, I started to hear a small hum in my speakers (subwoofer) and replaced them. The new one also got the issues then I found our that its a grounding issue. I unplugged the PC's power chord. The monitor is still switched on. When I checked, there's current in the earth pin (ground pin). When I unplug the monitor, there's no current and the speaker is normal. Now, I have moved that monitor to my dad's machine and took his monitor. My question is, is it a big issues? The house's earthing system is working and its grounding the current. I won't feel it if I touch the machine like in many other cases. But still, is it good to keep that monitor attached to my machine? Can it harm the computer? What should I do?

    Read the article

  • Officially announced RAM support size doesn't apply to one of twin rigs with just one difference

    - by Deniz
    It'll take a little long to describe my situation but here goes the story : In January 2009 we bought (the OEM parts) two similar systems with just one difference. One of them had a Phenom X4 cpu and the other one (mine) a Phenom X3 cpu. At the beginning we had problems with both systems to power them on whilst having all of their ram slots being full. We decided to install the systems with just 2 slots populated and later try to install the rest of ram sticks. Both systems did succeed to support 3 sticks. We tried many different procedures to make the systems work with their fourth ram slots being populated. We waited for new bios updates and flashed the boards when they were available, we tried different ram sticks with different frequencies etc. One day while we were trying to install the fourth stick, the X4 machine did accept it. The other one did not. The most mind boggling thing was that after one of my trials the X3 system begun to not operate with the third slot populated. Our boards did have AMD 770 chipsets and we even tried to change the board of the X3 machine with another 770 chipset board. Now my questions are : Should we change the cpu ? What is causing the X3 system to not accept the fourth (or now the third) ram stick ? The manufacturers sites do claim that this boards do accept 4 ram sticks (but they only tested them with certain ram brands and models). What are the limitations for maximum ram configurations on motherboards ? Are there some "rules of thumb" except frequency, voltage, chip type considerations for which we did check our parts ? Our boards are : Gigabyte GA-MA770-DS3 Sapphire PC-AM2RX780 - PURE CrossFireX 770

    Read the article

  • Communicating via Command Mode with IBM HS22 IMM via AMM

    - by MikeyB
    On previous model blades that contained a BMC, I was able to communicate from our external management station via pass-through commands to the BMC to do things such as power blades on/off, set VPD parameters, reboot the BMC, etc. Now on the HS22, a bunch of things happen differently. For example, we can no longer use the same pass-through commands to write VPD information pages and have them persist across reboots of the IMM - it looks as though those VPD pages are populated from information contained in the IMM. How do we use the Advanced Settings Utility from an external host to communicate with HS22 IMMs? Alternatively, what TCP Command Mode commands do we need to send to the AMM to communicate with the IMM? For our purposes, we specifically cannot communicate with the IMM from the blade itself. Specific example: When I send a pass-thru IPMI command via the AMM to the blade BMC to write information (such as MTM, Serial) into VPD page 0x10, it persists on blades with a BMC (HS21 for example). I can send the same IPMI command to write data to the VPD page on the HS22, however it does not persist across reboots of the IMM. What IPMI commands do I need to send to the IMM? What IPMI commands are asu sending when it sets the MTM & Serial?

    Read the article

  • Dell Inspiron 1564 overheating but fan not switching on, how to diagnose?

    - by Smugrik
    I've got a Dell Inspiron 1564 laptop that is about one and a half years old. Since about a week, the laptop started to overheat, causing it to switch off unexpectedly... The cpu fan is working erratically, it can start to spin for a while, doing its job and cooling down the cpu before it stops, but then the temperature goes up, and the fan doesn't reacts, once the temperature reaches a critical point (over 85 celsius, checked with speedfan...), the laptop switches off... I already cleaned the vents and fan from dust, to no avail, and it was actually quite clean anyway. Drivers and bios are up-to-date, no crapware was ever installed on this machine. I don't know how to diagnose the problem, could it be the temperature sensors that sends wrong information, so the fan doesn't reacts? but then I believe the computer wouldn't detect the overheat and stop... Is there a way I can pin point the problem? Maybe some low-level diagnostic tools to check functionality of sensors and fans??? The warranty is already over so any suggestion would be welcome. Thanks!!

    Read the article

  • How can I remotely tell what brand/model internal SCSI card is installed in a machine?

    - by edmicman
    I am doing some consulting work for a previous employer upgrading and migrating old servers to new hardware. There is an existing file server (HP ProLiant DL380) that has an tape backup drive connected; it is using a SCSI interface and I'm pretty sure it's using an internal SCSI card. They are upgrading to a new server hardware (HP ProLiant DL160 G6). The old server is 2U, the new one 1U and we would want to move the tape drive to the new server, too. I'm trying to figure out if the SCSI card in the old server would be able to be installed in the new one or if we'll need to source a new card; mostly I don't know for sure the height of the card and if it's low-profile enough that it would fit in the new server. There is not much of a technical resource onsite and the old server is in-use anyway so I would like to avoid making a trip in myself or trying to have someone onsite pop open the case and tell me what card is there. It's running Windows Server 2003 - is there a way to tell from say Device Manager what make and model the SCSI card might be? Or any other system diagnostic program or something that would give me hardware info like that? Thanks for any info!

    Read the article

  • How do I troubleshoot a slow hard drive?

    - by Bruce Connor
    My computer is suffering of slow-downs and I'm not surprised (it's around 6 years old). Here's what I've verified: They are not very frequent (only a couple of times a day). When they happen a single application will hang for 10-60 seconds, while the rest don't hang but also get slow. Even as it is happening, the CPU usage stays low. It happens to applications (such as text editor, firefox, skype). It never happens to some applications (such as games) which I use for hours under heavy CPU load. Also of note: The Graphics card and PSU are new (around a year). Though I have a decent amount of software installed right now, this was happening even right after I reinstalled Windows. This HDD has been through many partinioning schemes, and a few heavy operations (such as moving around 200GB of data). Because of the above, I am already 70% sure the problem is with the hard drive. Before I replace it, however, I want to rule out other less likely possibilities (such as RAM, software, or PSU). I don't have the money to replace the entire box right now, but I can easily replace one of the components. I've read several questions (such as this one) which give general guidance on troubleshooting an unknown issue, that is not what I'm looking for here. My main question is: What tests or benchmarks can I run to verify I have a problematic hard drive? I don't need to solve this problem, I am content with just making sure it's the hard drive. I could borrow a newer hard drive from a friend and see if it gets better. A positive result would rule out all other components, but it wouldn't rule out a software issue (since this new hard drive won't have any of the software I use daily). Running on Windows/Linux.

    Read the article

  • PostgreSQL lots of large Arrays and Writes

    - by strife911
    Hi, I am running a python program that spawns 8 threads and as each thread launch its own postmaster process via psycopg2. This is to maximize the use of my CPU-cores (8). Each thread call a series of SQL Functions. Most of these functions go through many thousands of rows each associated to a large FLOAT8[] Array (250-300) values by using unnest() and multiplying each FLOAT8 by an another FLOAT8 associated to each row. This Array approach minimized the size of the Indexes and the Tables. The Function ends with an Insert into another Table of a row of the same form (pk INT4, array FLOAT8[]). Some SQL Functions called by python will Update a row of these kind of Tables (with large Arrays). Now I currently have configured PostgreSQL to use most of the memory for cache (effective_cache_size of 57 GB I think) and only a small amount of it for shared memory (1GB I think). First, I was wondering what the difference between Cache and Shared memory was in regards to PostgreSQL (and my application). What I have noticed is that only about 20-40% of my total CPU processing power is used during the most Read intensive parts of the application (Select unnest(array) etc). So secondly, I was wondering what I could do to improve this so that 100% of the CPU is used. Based on my observations, it does not seem to have anything to do with python or its GIL. Thanks

    Read the article

  • Give back full control to a user on a disk from another computer

    - by Foghorn
    I have my friend's hard drive mounted externally. After messing with the permissions with TAKEOWN so I could fix some viruses, I have full control over their drive. The problem is, now it's stuck in a "autochk not found" reboot sequence. I think the problem is that the boot sector is invisible to the drive now. So my question is, How can I use icacls to give back the full ownership, when the user I am giving it to is not on my machine? I ran the TAKEOWN command from my windows 7 laptop, their machine is a windows xp Professional with three partitions, I only altered the one that has the boot sector. Here is the permissions that icacls shows: (Where my computer is %System% my username is ME, and the drive is E:\ C:\Users\ME icacls E:\* E:\$RECYCLE.BIN %System%\ME:(OI)(CI)(F) Mandatory Label\Low Mandatory Level:(OI)(CI)(IO)(NW) E:\ALLDATAW %System%\ME:(I)(OI)(CI)(F) E:\alrt_200.data %System%\ME:(OI)(CI)(F) E:\AUTOEXEC.BAT %System%\ME:(OI)(CI)(F) E:\AZ Commercial %System%\ME:(I)(OI)(CI)(F) E:\boot.ini %System%\ME:(OI)(CI)(F) E:\Config.Msi %System%\ME:(I)(OI)(CI)(F) E:\CONFIG.SYS %System%\ME:(OI)(CI)(F) E:\Documents and Settings %System%\ME:(I)(OI)(CI)(F) E:\IO.SYS %System%\ME:(OI)(CI)(F) E:\Mitchell1 %System%\ME:(I)(OI)(CI)(F) E:\MSDOS.SYS %System%\ME:(OI)(CI)(F) E:\MSOCache %System%\ME:(I)(OI)(CI)(F) E:\NTDClient.log %System%\ME:(OI)(CI)(F) E:\NTDETECT.COM %System%\ME:(OI)(CI)(F) E:\ntldr %System%\ME:(OI)(CI)(F) E:\pagefile.sys %System%\ME:(OI)(CI)(F) E:\Program Files %System%\ME:(I)(OI)(CI)(F) E:\RECYCLER %System%\ME:(I)(OI)(CI)(F) E:\RHDSetup.log %System%\ME:(OI)(CI)(F) E:\System Volume Information %System%\ME:(I)(OI)(CI)(F) E:\WINDOWS %System%\ME:(I)(OI)(CI)(F) Successfully processed 22 files; Failed processing 0 files C:\Users\ME

    Read the article

  • Dell Poweredge 1950 with Perc 5i keeps losing raid config -> "Foreign Configuration Found"

    - by nosage
    The quick and dirty: the machine is a Dell Poweredge 1950, dual xeon quad cores, 8GB of ram, 2 2TB seagate SATAs in (supposed to be raid1) using a Perc 5i raid card. They are hot-swappable with a back-plane. I can build the raid fine and after a little while an install of server 08 r2 will blue screen and restart. When it comes up the raid controller says "Foreign Configuration Found." When I go into the raid configuration panel there is no raid listed but I can import the "foreign config", and the OS will boot up fine, until it blue screens again after a little while. The issue is OS independent. I have tried swapping raid cards, swapping the RAM module on the raid card and swapping the raid battery, all to no avail. Its almost as if there is a loose connection from the raid card to the back plane and both of disks get lost and the raid card drops the config. But it sees the disks fine when it boots back up. The raid card uses a SCSI SAS cable to connect to the back-plane so I guess the next step is to replace that, but... then I might as well replace the back-plane with a SCSI SAS to sata breakout cable, but... then I need a way to power the disks. Sorry for the wall of txt but it would be great to get some thoughts from people who worked with perc raid cards or poweredge servers with this type of issue before. Ironically I want to get this system up and running so I can work on MCITP labs. Thank you for any/all help and feel free to ask questions!

    Read the article

  • vmware vmdk disk problem

    - by dmtr
    I have a VMware ESXi 4 server and 2 storage servers (mounted via nfs). Between the storage servers (Fedora 14) is a drbd cluster (dual primary) and ocfs2 filesystem; also every server has a local partition with an ext4 filesystem, both are mounted via nfs on the esxi server. When I tried to copy a virtual machine (naturally it was powered off) from the ext4 partition to the ocfs2 partition, the vmdk total file size is different, but the md5sum is the same. On the ext4 partition: # ls -la total 28492228 -rw------- 1 root root 42949672960 Jan 14 14:46 disk-flat.vmdk # md5sum disk-flat.vmdk 0eaebe3138beb32f54ea5de6dfe5a987 On the ocfs2 partition: # ls -la total 13974660 -rw------- 1 root root 42949672960 Jan 14 16:16 disk-flat.vmdk # md5sum disk-flat.vmdk 0eaebe3138beb32f54ea5de6dfe5a987 When I power on the virtual machine from the ocfs2 partition it dosn't work. I have a windows on the virtual machine and it freez?s after the windows logo. From the ext4 partition the virtual machine workes. I tested with linux (created and installed on ext4 partition and then copied to the ocfs2) and the same problem appears. When I create a virtual machine directly from ocfs2 partition, there are no problems. I tried to copy via vSphere client, and I have the same problem. Any suggestions?

    Read the article

  • Mainboard shuts itself off after half a second or so

    - by heishe
    Here's the problem: When I start the PC, the mainboard powers up, then stays that way maybe 0.2-0.5 seconds, and then shuts off again. I say mainboard, and not PC, because I removed all the parts from the system and disconnected everything but the mainboard power supply (the broad 12 pin thingy). When I have the other parts (cpu, graphics card, ram, etc.) installed and connected, the basic behaviour stays the same, but now the mainboard runs for about 6 or 7 seconds (this is a guess) before shutting off. This all started when my monitor wouldn't receive a video signal today, without giving POSTs, so I took the graphics card and the RAM out to see if it changes anything. It didn't, except that from that point on the mainboard would start to have this behavior where it just stays on for a very short time and then shuts off again. I already tested it with a backup PSU - same behavior. What could this be? I'm thinking it can't be on a physical level (transistors burned through or something like that), since then the mainboard either shouldn't start at all or it should detect hardware failures in non-essential parts of the syste and start beeping. Sorry, I forgot to mention. It's an MSI P67A-C43. I already checked the capacitors if someone popped, but I can't find anything. I also tried resetting the cmos, but that didn't change anything.

    Read the article

  • does my machine configuration make sense?

    - by user1227914
    i couldn't think of a better place to ask this question, so here it goes. we're putting together a dedicated server for a website that will initially host the web server and the mysql database. as the website grows, we'll move the database to a different server and this machine will eventually only server the actual website. so the question is ...does my configuration look okay? it's the first time i'm building a server from scratch so i want to make sure i don't combine components that don't fit or something. things like ..do the drives i picked work for the hot swap ..etc. what do you guys think? am i good to go with this configuration? :) Chassis: Supermicro SuperServer 6016T-MTHF (6x DDR3 SDRAM - ECC DIMM 240-pin, 2x LGA1366 Socket, Power Provided: 600 Watt, 4 (free) x hot-swap - 3.5") CPU: Intel BX80614E5620 Xeon E5620 Processor - 4 Core, 2.40GHz, LGA 1366, 5.86GT/s QPI 12MB Cache, 64-Bit, 80W, HyperThreading Memory: Crucial CT51272BB1339 4GB PC10600 DDR3 Memory - 1333MHz, ECC, Registered, 1x4096MB (possibly 3 or 4 of them) Hard Drives: Western Digital WD2002FAEX Caviar Black Hard Drive - 2TB, 3.5", SATA 6Gbps, 7200 RPM, 64MB (possibly 2 or 3). thank you very much for any professional advice :)

    Read the article

  • SYS-5016T-MTFB will not POST without manual assistance (Motherboard: X8STi-F)

    - by Dan
    I have a Supermicro 5016T-MTFB 1U server which I am in the process of setting up, but it has a really strange problem. When the system is powered on it will not POST until I press the reset button a few times, followed by pressing the delete key on the keyboard to "wake it up". If I power it on and do nothing, the fans spin up but nothing else happens at all. After pressing the reset button once, the red "overheat" light comes on and blinks which is supposed to indicate a fan failure - but all the fans are working. Pressing reset again usually stops the blinking, and the system starts the normal POST routine but it will not actually get to the bios screen unless I press delete. If I don't press delete, it just continues to hang. After pressing delete it will take me into the bios setup screen, if I exit without saving changes I can boot the system normally. I was able to successfully install Linux with no trouble...but upon rebooting the same problem happened again. This board has integrated IPMI which I thought was the problem, so I disabled it via the jumper on the board. Did not help. Each time this system powers on, it goes on for a second, then turns off again for another second, then turns back on again. I don't know why it does that. Here is what I put in the system: 1 x Xeon E5630 (Nehalem) 80W TDP (it's not overheating, CPU temps stay under 40 degrees C) 2 x Kingston 2GB x 3 DDR3-1066 Memory ECC, unbuffered, unregistered (kvr1066d3e7sk3/6g) 1 x Intel X25-M 160 GB 2 x Western Digital RE3 1TB