  • Statically Compiling Qt 4.6.2

    - by geeko
    This what I did but it results in errors: 1: In win32-msvc2008\qmake.conf I set QMAKE_CFLAGS_RELEASE = -O1 -Og -GL -MD 2: From MSVC2008 CMD I run vcvarsall.bat x86 and vcvars32.bat "C:\Program Files\Microsoft Visual Studio 9.0\VC\bin 3: From Qt 4.6.2 CMD I run the following C:\Qt\4.6.2configure -release -nomake examples -nomake demos -no-exceptions -n o-stl -no-rtti -no-qt3support -no-scripttools -no-openssl -no-opengl -no-webkit -no-phonon -no-style-motif -no-style-cde -no-style-cleanlooks -no-style-plastique -no-sql-sqlite -platform win32-msvc2008 -static -qt-libjpeg -qt-zlib -qt-libpng and then nmake However, I ended up every time with these errors: link /LIBPATH:"c:\Qt\4.6.2\lib" /LIBPATH:"c:\Qt\4.6.2\lib" /NOLOGO /INCR EMENTAL:NO /MANIFEST /MANIFESTFILE:"tmp\obj\release_static\assistant_adp.interme diate.manifest" /SUBSYSTEM:WINDOWS "/MANIFESTDEPENDENCY:type='win32' name='Micro soft.Windows.Common-Controls' version='6.0.0.0' publicKeyToken='6595b64144ccf1df ' language='' processorArchitecture=''" /OUT:......\bin\assistant_adp.exe @C :\DOCUME~1\Geeko\LOCALS~1\Temp\nm3F8.tmp fontpanel.obj : MSIL .netmodule or module compiled with /GL found; restarting li nk with /LTCG; add /LTCG to the link command line to improve linker performance main.obj : error LNK2001: unresolved external symbol "class QObject * __cdecl qt _plugin_instance_qjpeg(void)" (?qt_plugin_instance_qjpeg@@YAPAVQObject@@XZ) ......\bin\assistant_adp.exe : fatal error LNK1120: 1 unresolved externals NMAKE : fatal error U1077: '"C:\Program Files\Microsoft Visual Studio 9.0\VC\BIN \link.EXE"' : return code '0x460' Stop. NMAKE : fatal error U1077: '"C:\Program Files\Microsoft Visual Studio 9.0\VC\BIN \nmake.exe"' : return code '0x2' Stop. NMAKE : fatal error U1077: 'cd' : return code '0x2' Stop. NMAKE : fatal error U1077: 'cd' : return code '0x2' Stop. NMAKE : fatal error U1077: 'cd' : return code '0x2' Stop. Thank you in deed.

    Read the article

  • What is the difference: LoadUserProfile -vs- RegOpenCurrentUser

    - by Will5801
    These two APIs are very similar but it is unclear what the differences are and when each should be used (Except that LoadUserProfile is specified for use with CreateProcessAsUser which I am not using. I am simply impersonating for hive accesss). LoadUserProfile http://msdn.microsoft.com/en-us/library/bb762281(VS.85).aspx RegOpenCurrentUser http://msdn.microsoft.com/en-us/library/ms724894(VS.85).aspx According to the Services & the Registry article: http://msdn.microsoft.com/en-us/library/ms685145(VS.85).aspx we should use RegOpenCurrentUser when impersonating. But what does/should RegOpenCurrentUser do if the user profile is roaming - should it load it? As far as I can tell from these docs, both APIs provide a handle to the HKEY_CURRENT_USER for the user the thread is impersonating. Therefore, they both "load" the hive i.e. lock it as a database file and give a handle to it for registry APIs. It might seem that LoadUserProfile loads the user profile in the same way as the User does when he/she logs on, whereas RegOpenCurrentUser does not - is this correct? What is the fundamental difference (if any) in how these two APIs mount the hive? What are the implications and differences (if any) between what happens IF A user logs-on or logs-off while each of these impersonated handles is already in use? A user is already logged-on when each matching close function (RegCloseKey and UnloadUserProfile) is called?

    Read the article

  • Error generating Interface with svcutil.exe

    - by capdragon
    Can someone help me generate the Interface (c#) file for the following OGC schema? Schema files: Download Schema Files Link I need to create web services for the Ordering wsdl in the schema zip file above. I've been at it for days now with no luck generating the interface. I've tried: svcutil.exe thewsdl.wsdl /language:c# /out:ITheInterface.cs svcutil Order.wsdl /out:IOrder.cs svcutil Order.wsdl Order.xsd ..\ws-addressing\ws-addr.xsd /out:IOrder.cs svcutil Order.wsdl Order.xsd ws-addr.xsd /out:IOrder.cs and i get the following error: Microsoft (R) Service Model Metadata Tool [Microsoft (R) Windows (R) Communication Foundation, Version 4.0.30319.1] Copyright (c) Microsoft Corporation. All rights reserved. Error: Cannot read ws-addr.xsd. Cannot load file D:\Documents\DEV\SARPilot\Docs\eoschema\schema\OrderSchema\ws-addr.xsd as an Assembly. Check the FusionLogs f or more Information. Could not load file or assembly 'file:///D:\Documents\DEV\SARPilot\Docs\eoschema\schema\OrderSchema\ws-addr.xsd' or one of its dependencies. The module was expected to contain an assembly manifest.

    Read the article

  • Binding WPF ComboBox in XAML - Why is it Empty?

    - by mdiehl13
    I am trying to learn how to bind my simple database (.sdf) to a combobox. I created a dataset with my tables in it. I then dragged a table from the DataSource onto my control. There are no build warnings/errors, and when it runs, the ComboBox is empty. <UserControl x:Class="OurFamilyFinances.TabItems.TransactionTab" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:mc="http://schemas.openxmlformats.org/markup-compatibility/2006" xmlns:d="http://schemas.microsoft.com/expression/blend/2008" mc:Ignorable="d" d:DesignHeight="414" d:DesignWidth="578" xmlns:my="clr-namespace:OurFamilyFinances" Loaded="UserControl_Loaded_1"> <UserControl.Resources> <my:FinancesDataDataSet x:Key="financesDataDataSet" /> <CollectionViewSource x:Key="accountViewSource" Source="{Binding Path=Account, Source={StaticResource financesDataDataSet}}" /> </UserControl.Resources> <Grid> <ComboBox DisplayMemberPath="Name" Height="23" HorizontalAlignment="Left" ItemsSource="{Binding Source={StaticResource accountViewSource}}" Margin="3,141,0,0" Name="accountComboBox" SelectedValuePath="ID" VerticalAlignment="Top" Width="120"> <ComboBox.ItemsPanel> <ItemsPanelTemplate> <VirtualizingStackPanel /> </ItemsPanelTemplate> </ComboBox.ItemsPanel> </ComboBox> </Grid> The paths that is shows are correct, the selectedPath is "ID" and the displaypath is "Name". If I do this in Linq to Sql, the combo box does populate: this.accountComboBox.ItemsSource = from o in db.Account select new { o.ID, o.Name }; But I would like to learn how to do this in XAML. I have dragged datagrids from the DataSource as well, but they are not populated either. Any idea?

    Read the article

  • SQL Server 2008 Express Edition Connection Problem

    - by waqasahmed
    I have VS 2008 Professional Edition. After the installation (which included SQL Server 2008), I decided to install SQL Server 2008 Express Edition with Advanced Tools (so I could get SQL Server Management Studio on it). So I uninstalled the SQL Express that came with VS 2008, and installed the standalone SQL Server Express 2008 version with advanced tools. However, When I try to logon onto SQL Server Management Studio using: .\SQLEXPRESS as Server name and Windows Authentication as the authentication, I get the following message: TITLE: Connect to Server ------------------------------ Cannot connect to .\SQLEXPRESS. ------------------------------ ADDITIONAL INFORMATION: A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. (provider: SQL Network Interfaces, error: 26 - Error Locating Server/Instance Specified) (Microsoft SQL Server, Error: -1) For help, click: http//go.microsoft.com/fwlink?ProdName=Microsoft+SQL+Server&EvtSrc=MSSQLServer&EvtID=-1&LinkId=20476 ------------------------------ BUTTONS: OK ------------------------------ Any suggestions on how to get it to work? I have tried disabling Windows Firewall as well and still no luck. I am using WIndows Vista and SQL Server 2008 Express SP1 Patch has also been applied recently.

    Read the article

  • Guaranteed way to find the ildasm.exe and ilasm.exe files regardless of .NET version/environment?

    - by m-y
    Is there a way to programmatically get the FileInfo/Path of the ildasm.exe/ilasm.exe executables? I'm attempting to decompile and recompile a dll/exe file appropriately after making some alterations to it (I'm guessing PostSharp does something similar to alter the IL after the compilation). I found a blog post that pointed to: var pfDir = Environment.GetFolderPath(Environment.SpecialFolders.ProgramFiles)); var sdkDir = Path.Combine(pfDir, @"Microsoft SDKs\Windows\v6.0A\bin"); ... However, when I ran this code the directory did not exist (mainly because my SDK version is 7.1), so on my local machine the correct path is @"Microsoft SDKs\Windows\v7.1\bin". How do I ensure I can actually find the ildasm.exe? Similarly, I found another blog post on how to get access to ilasm.exe as: string windows = Environment.GetFolderPath(Environment.SpecialFolder.System); string fwork = Path.Combine(windows, @"..\Microsoft.NET\Framework\v2.0.50727"); ... While this works, I noticed that I have Framework and Framework64, and within Framework itself I have all of the versions up to v4.0.30319 (same with Framework64). So, how do I know which one to use? Should it be based on the .NET Framework version I'm targetting? Summary: How do I appropriately guarantee to find the correct path to ildasm.exe? How do I appropriately select the correct ilasm.exe to compile?

    Read the article

  • How to launch correct version of Msbuild

    - by Rory Becker
    When I type... Msbuild<Enter> ... At the command prompt, I get... Microsoft (R) Build Engine Version 2.0.50727.4927 [Microsoft .NET Framework, Version 2.0.50727.4927] Copyright (C) Microsoft Corporation 2005. All rights reserved. This is all very well and good except that when I run this against a vs2010 .sln file, the error message indicates: MyProject.sln(2): Solution file error MSB5014: File format version is not recognized. MSBuild can only read solution files between versions 7.0 and 9.0, inclusive. 0 Warning(s) 1 Error(s) It would appear that the version of msbuild that is being called, is not capable of understanding my solution file. I figured that I would check out my path and see where msbuild is being picked up from. However, it seems that no part of my path points at a location where msbuild is to be found. How is the command line finding the copy of msbuild that it is using and how can I change this version so that the latest version is used?

    Read the article

  • WPF - How to properly reference a class from XAML

    - by Andy T
    OK, this is a super super noob question, one that I'm almost embarrassed to ask... I want to reference a class in my XAML file. It's a DataTemplateSelector for selecting the right edit template for a DataGrid column. Anyway, I've written the class into my code behind, added the local namespace to the top of top of the XAML, but when I try to reference the class from the XAML, it tells me the class does not exist in the local namespace. I must be missing something really really simple but I just can't understand it... Here's my code. XAML: <Window xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:tk="http://schemas.microsoft.com/wpf/2008/toolkit" xmlns:local="clr-namespace:CustomFields" xmlns:col="clr-namespace:System.Collections;assembly=mscorlib" xmlns:sys="clr-namespace:System;assembly=mscorlib" x:Class="CustomFields.MainWindow" x:Name="Window" Title="Define Custom Fields" Width="425" Height="400" MinWidth="425" MinHeight="400"> <Window.Resources> <ResourceDictionary> <local:RangeValuesEditTemplateSelector> blah blah blah... </local:RangeValuesEditTemplateSelector> </ResourceDictionary> </Window.Resources> C#: namespace CustomFields { /// /// Interaction logic for MainWindow.xaml /// public partial class MainWindow : Window { public MainWindow() { this.InitializeComponent(); // Insert code required on object creation below this point. } } public class RangeValuesEditTemplateSelector : DataTemplateSelector { public RangeValuesEditTemplateSelector(){ MessageBox.Show("hello"); } } } Any ideas what I'm doing wrong? I thought this should be simple as 1-2-3... Thanks! AT

    Read the article

  • Calling unmanaged dll from C#. Take 2

    - by Charles Gargent
    I have written a c# program that calls a c++ dll that echoes the commandline args to a file When the c++ is called using the rundll32 command it displays the commandline args no problem, however when it is called from within the c# it doesnt. I asked this question to try and solve my problem, but I have modified it my test environment and I think it is worth asking a new question. Here is the c++ dll #include "stdafx.h" #include "stdlib.h" #include <stdio.h> #include <iostream> #include <fstream> using namespace std; BOOL APIENTRY DllMain( HANDLE hModule, DWORD ul_reason_for_call, LPVOID lpReserved ) { return TRUE; } extern "C" __declspec(dllexport) int WINAPI CMAKEX( HWND hwnd, HINSTANCE hinst, LPCSTR lpszCommandLine, DWORD dwReserved) { ofstream SaveFile("output.txt"); SaveFile << lpszCommandLine; SaveFile.close(); return 0; } Here is the c# app using System; using System.Collections.Generic; using System.Text; using System.Security.Cryptography; using System.Runtime.InteropServices; using System.Net; namespace nac { class Program { [DllImport("cmakca.dll", SetLastError = true, CharSet = CharSet.Unicode)] static extern bool CMAKEX(IntPtr hwnd, IntPtr hinst, string lpszCmdLine, int nCmdShow); static void Main(string[] args) { string cmdLine = @"/source_filename proxy-1.txt /backup_filename proxy.bak /DialRasEntry NULL /TunnelRasEntry DSLVPN /profile ""C:\Documents and Settings\Administrator\Application Data\Microsoft\Network\Connections\Cm\dslvpn.cmp"""; const int SW_SHOWNORMAL = 1; CMAKEX(IntPtr.Zero, IntPtr.Zero, cmdLine, SW_SHOWNORMAL).ToString(); } } } The output from the rundll32 command is rundll32 cmakex.dll,CMAKEX /source_filename proxy-1.txt /backup_filename proxy.bak /DialRasEntry NULL /TunnelRasEntry DSLVPN /profile ""C:\Documents and Settings\Administrator\Application Data\Microsoft\Network\Connections\Cm\dslvpn.cmp" /source_filename proxy-1.txt /backup_filename proxy.bak /DialRasEntry NULL /TunnelRasEntry DSLVPN /profile ""C:\Documents and Settings\Administrator\Application Data\Microsoft\Network\Connections\Cm\dslvpn.cmp" however the output when the c# app runs is /

    Read the article

  • How to call a C# DLL from InstallerClass overrides?

    - by simpleton
    I have a setup and deployment project. In it I have an Installer.cs class, created from the basic Installer Class template. In the Install override, I have this code taken from http://msdn.microsoft.com/en-us/library/d9k65z2d.aspx. public override void Install(IDictionary stateSaver) { base.Install(stateSaver); System.Diagnostics.Process.Start("http://www.microsoft.com"); } Everything works when I install the application, but the problem arises when I try to call anything from an external C# class library that I also wrote. Example: public override void Install(IDictionary stateSaver) { base.Install(stateSaver); System.Diagnostics.Process.Start("http://www.microsoft.com"); MyLibrary.SomeMethod(); } The problem is, I don't believe the library call is actually happening. I tagged the entire process line by line, with EventLog.WriteEvent()s, and each line in the Install override is seemlingly 'hit', putting entries in the event log, but I do not receive any exceptions for the library call SomeMethod(), yet the EventLog entries and other actions inside SomeMethod() are never created nor any of its actions taken. Any ideas?

    Read the article

  • How to get the sending email address from outlook 2007

    - by Naresh
    I am working on outlook add-in project using Visual studio 2008 for MS Outlook 2007 in C#. Here I am explaining my problem... I got multiple accounts (3 Accounts) with my outlook 2007. I need to get accounts form Account box in New Mail Message window. When we click New Mail Message, a new window will appear from which we can send a new mail. Here (On this window) we can see Account Dropdown (Left side) under the Send Button. If we have multiple accounts with outlook, we can see all the accounts in Account Drop Down if we click on Account Box. If we click on the particular email, a right mark will appear to that Email Account and a message can bee seen on the top of the Send button is "This message will be sent via [email protected]". So, I want to get these email accounts into a string and that particular email account (which has right mark) into another string. I got these 3 email accounts into a string. But, I am not getting the particular email account(which has the right mark when we send a new email). I am using this code.... using Outlook = Microsoft.Office.Interop.Outlook; using Office = Microsoft.Office.Core; using Microsoft.Office.Interop.Outlook; Outlook._Application myOutlookApp = new Outlook.Application(); Outlook.Accounts myAccounts = myOutlookApp.Session.Accounts; foreach (Outlook.Account account in myAccounts) { string emailAddress = account.SmtpAddress; } I am able to get all the accounts from the above code..But, I just want to get the email address which we will use for sending an email at that particular moment..

    Read the article

  • PowerShell: How to find and uninstall a MS Office Update

    - by Hank
    I've been hunting for a clean way to uninstall an MSOffice security update on a large number of workstations. I've found some awkward solutions, but nothing as clean or general like using PowerShell and get-wmiobject with Win32_QuickFixEngineering and the .Uninstall method on the resulting object. [Apparently, Win32_QuickFixEngineering only refers to Windows patches. See: http://social.technet.microsoft.com/Forums/en/winserverpowershell/thread/93cc0731-5a99-4698-b1d4-8476b3140aa3 ] Question 1: Is there no way to use get-wmiobject to find MSOffice updates? There are so many classes and namespaces, I have to wonder. This particualar Office update (KB978382) can be found in the registry here (for Office Ultimate): HKLM\Software\Microsoft\Windows\CurrentVersion\Uninstall\{91120000-002E-0000-0000-0000000FF1CE}_ULTIMATER_{6DE3DABF-0203-426B-B330-7287D1003E86} which kindly shows the uninstall command of: msiexec /package {91120000-002E-0000-0000-0000000FF1CE} /uninstall {6DE3DABF-0203-426B-B330-7287D1003E86} and the last GUID seems constant between different versions of Office. I've also found the update like this: $wu = new-object -com "Microsoft.Update.Searcher" $wu.QueryHistory(0,$wu.GetTotalHistoryCount()) | where {$_.Title -match "KB978382"} I like this search because it doesn't require any poking around in the registry, but: Question 2: If I've found it like this, what can I do with the found information to facilitate the Uninstall? Thanks

    Read the article

  • Windows update breaks dlls?

    - by shoosh
    I'm compiling a project which uses multiple DLL and compiles with VS2008. After a recent windows update DLLs compiled on my computer stopped working on other computers. After some investigation it turned out that it updated the CRT redistributable library which I'm compiling with from version "9.0.21022.8" to version "9.0.30729.4148" This is evident from the Manifest file of the EXE i'm compiling. it contains the following: <dependency> <dependentAssembly> <assemblyIdentity type="win32" name="Microsoft.VC90.CRT" version="9.0.21022.8" processorArchitecture="amd64" publicKeyToken="1fc8b3b9a1e18e3b"></assemblyIdentity> </dependentAssembly> </dependency> <dependency> <dependentAssembly> <assemblyIdentity type="win32" name="Microsoft.VC90.CRT" version="9.0.30729.4148" processorArchitecture="amd64" publicKeyToken="1fc8b3b9a1e18e3b"></assemblyIdentity> </dependentAssembly> </dependency> Meaning it wants to use two different versions of the CRT at the same time. the second version is needed by the code which I'm compiling right now and the first version is needed by older dlls which were compiled a few weeks ago. In the computers where the application is deployed this becomes a problem since they get their CRT dll from a local folder called Microsoft.VC90.CRT and not from WinSXS. This folder can't contain two different versions of the dll. Is there a known solution to this issue or do I need to start compiling all of the other DLLs with the new CRT?

    Read the article

  • Making .NET assembly COM-visible and working for VB5

    - by Cyberherbalist
    I have an assembly which I have managed to make visible to VB6 and it works, but having a problem accomplishing the same thing with VB5. For VB6, I have built the assembly, made it COM-visible, registered it as a COM object etc., and the assembly shows in VB6's References list, and allows me to use it successfully. The Object Browser also shows the method in the assy. I copied the assembly and its TLB to a virtual workstation used for VB5 development, and ran Regasm, apparently successfully: C:\>C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727 \regasm arserviceinterface.dll /tlb:arserviceinterface.tlb Microsoft (R) .NET Framework Assembly Registration Utility 2.0.50727.3053 Copyright (C) Microsoft Corporation 1998-2004. All rights reserved. Assembly exported to 'C:\Projects\AR\3rd Party\ARService\arserviceinterface.tlb' , and the type library was registered successfully Note that the virtual W/S is Win2k and does not have .NET Fx 3.5 on it, just 2.0. The assembly shows up in the References that can be selected in VB5, but the method of the assembly doesn't show up in the Object Browser, and it is generally unusable. Either there is a step to do that I haven't done, or VB5 doesn't know how to use such a COM object. Note that the VB5 setup is on a virtual workstation, not the same workstation that VB6 is installed on. Any ideas? One thing that occurred to me is that I might need to generate and use a strong name on the workstation in question, but...

    Read the article

  • COM: How to handle a specific exception?

    - by Ian Boyd
    i'm talking to a COM object (Microsoft ADO Recordset object). In a certain case the recordset will return a failed (i.e. negative) HRESULT, with the message: Item cannot be found in the collection corresponding to the requested name or ordinal i know what this error message means, know why it happened, and i how to fix it. But i know these things because i read the message, which fortunately was in a language i understand. Now i would like to handle this exception specially. The COM object threw an HRESULT of 0x800A0CC1 In an ideal world Microsoft would have documented what errors can be returned when i try to access: records.Fields.Items( index ) with an invalid index. But they do not; they most they say is that an error can occur, i.e.: If Item cannot find an object in the collection corresponding to the Index argument, an error occurs. Given that the returned error code is not documented, is it correct to handle a specific return code of `0x800A0CC1' when i'm trying to trap the exception: Item cannot be found in the collection corresponding to the requested name or ordinal ? Since Microsoft didn't document the error code, they technically change it in the future.

    Read the article

  • Why are all objects in this extension of usercontrol null at runtime?

    - by csciguy
    All, I have a simple class. public class Container : UserControl { public bool IsClickable { get; set; } } I have a class that extends this class. public class ScrollingContainer : Container { public void Draw() { } public void Update() { } } I have a custom class, that then extends ScrollingContainer. public partial class MaskContainer : ScrollingContainer { public MaskContainer() { InitializeComponent(); } } XAML <local:ScrollingContainer x:Class="Test.Types.MaskContainer" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:d="http://schemas.microsoft.com/expression/blend/2008" xmlns:mc="http://schemas.openxmlformats.org/markup-compatibility/2006" xmlns:local="clr-namespace:GameObjects;assembly=GameObjects" mc:Ignorable="d" > </local:ScrollingContainer> In my mainpage.xaml, I have the following. <types:MaskContainer x:Name="maskContainer" Canvas.ZIndex="1" Width="Auto" Height="Auto"> <Canvas x:Name="maskCanvas"> <Button x:Name="button1" Content="test button"/> </Canvas> </types:MaskContainer> Why, at runtime, are both maskCanvas and button1 null? maskContainer is not null. The inheritance should be straightforward here. Container inherits usercontrol. Scrollable container inherits container. Mask Container inherits scrollable container. Why am I losing the fucntionality of the original base class at this level? Is it incorrect to add the element (button1) to the maskcontainer inside of the main.xaml? My end goal is to create a container that is reusable, but inherits all properties/methods that I've specified throughout the chain. Any help is appreciated.

    Read the article

  • Full-text search error during full-text index population : Error Code '0x80092003'

    - by user360074
    Dear All, I have problem with Full-Text Search service in production environment. Each time I rebuild full-text catalog, there is no error in User Interface, but there is no data in Full-Text Catalog Item Count : 0 Catalog size : 0 MB OS : Windows Server 2003 R2 Standard Edition Service Pack2 SQL Server Version : Microsoft SQL Server 2005 - 9.00.1399.06 (Intel X86) Oct 14 2005 00:33:37 Copyright (c) 1988-2005 Microsoft Corporation Standard Edition on Windows NT 5.2 (Build 3790: Service Pack 2) It work on dev server (windows xp professional version 2002 service pack 3) but error on prod server (Windows Server 2003 R2 Standard Edition Service Pack2) This is error log. Scrawl Log: 2010-06-02 03:51:31.06 spid24s Informational: Full-text Full population initialized for table or indexed view '[test1].[dbo].[test]' (table or indexed view ID '37575172', database ID '9'). Population sub-tasks: 1. 2010-06-02 03:51:31.06 spid24s Error '0x80092003' occurred during full-text index population for table or indexed view '[test1].[dbo].[test]' (table or indexed view ID '37575172', database ID '9'), full-text key value 0x00000006. Attempt will be made to reindex it. 2010-06-02 03:51:31.06 spid24s The component 'MSFTE.DLL' reported error while indexing. Component path 'D:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\Binn\MSFTE.DLL'. 2010-06-02 03:51:31.06 spid24s Error '0x80092003' occurred during full-text index population for table or indexed view '[test1].[dbo].[test]' (table or indexed view ID '37575172', database ID '9'), full-text key value 0x00000005. Attempt will be made to reindex it.

    Read the article

  • How to implement properly plugins in C#?

    - by MartyIX
    I'm trying to add plugins to my game and what I'm trying to implement is this: Plugins will be either mine or 3rd party's so I would like a solution where crashing of the plugin would not mean crashing of the main application. Methods of plugins are called very often (for example because of drawing of game objects). What I've found so far: 1) http://www.codeproject.com/KB/cs/pluginsincsharp.aspx - simple concept that seems like it should work nicely. Since plugins are used in my game for every round I would suffice to add the Restart() method and if a plugin is no longer needed Unload() method + GC should take care of that. 2) http://mef.codeplex.com/Wikipage - Managed Extensibility Framework - my program should work on .NET 3.5 and I don't want to add any other framework separately I want to write my plugin system myself. Therefore this solution is out of question. 3) Microsoft provides: http://msdn.microsoft.com/en-us/library/system.addin.aspx but according to a few articles I've read it is very complex. 4) Different AppDomains for plugins. According to Marc Gravell ( http://stackoverflow.com/questions/665668/usage-of-appdomain-in-c ) different AppDomains allow isolation. Unloading of plugins would be easy. What would the performance load be? I need to call methods of plugins very often (to draw objects for example). Using Application Domains - http://msdn.microsoft.com/en-us/library/yb506139.aspx A few tutorials on java2s.com Could you please comment on my findings? New approaches are also welcomed! Thanks!

    Read the article

  • Getting DirectoryNotFoundException when trying to Connect to Device with CoreCon API

    - by ageektrapped
    I'm trying to use the CoreCon API in Visual Studio 2008 to programmatically launch device emulators. When I call device.Connect(), I inexplicably get a DirectoryNotFoundException. I get it if I try it in PowerShell or in C# Console Application. Here's the code I'm using: static void Main(string[] args) { DatastoreManager dm = new DatastoreManager(1033); Collection<Platform> platforms = dm.GetPlatforms(); foreach (var p in platforms) { Console.WriteLine("{0} {1}", p.Name, p.Id); } Platform platform = platforms[3]; Console.WriteLine("Selected {0}", platform.Name); Device device = platform.GetDevices()[0]; device.Connect(); Console.WriteLine("Device Connected"); SystemInfo info = device.GetSystemInfo(); Console.WriteLine("System OS Version:{0}.{1}.{2}", info.OSMajor, info.OSMinor, info.OSBuildNo); Console.ReadLine(); } My question: Does anyone know why I'm getting this error? I'm running this on WinXP 32-bit, plain jane Visual Studio 2008 Pro. I imagine it's some config issue since I can't do it from a Console app or PowerShell. Here's the stack trace as requested: System.IO.DirectoryNotFoundException was unhandled Message="The system cannot find the path specified.\r\n" Source="Device Connection Manager" StackTrace: at Microsoft.VisualStudio.DeviceConnectivity.Interop.ConManServerClass.ConnectDevice() at Microsoft.SmartDevice.Connectivity.Device.Connect() at ConsoleApplication1.Program.Main(String[] args) in C:\Documents and Settings\Thomas\Local Settings\Application Data\Temporary Projects\ConsoleApplication1\Program.cs:line 23 at System.AppDomain._nExecuteAssembly(Assembly assembly, String[] args) at System.AppDomain.ExecuteAssembly(String assemblyFile, Evidence assemblySecurity, String[] args) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart() InnerException:

    Read the article

  • Outlook 2010 Retrieving and restricting appointments programmatically causing recurrences to be incl

    - by Mike Dearing
    I wrote a winforms app that uses Microsoft.Office.Interop.Outlook to retrieve and restrict appointments based upon the date range entered by a user. This worked fine with Outlook 2007 installed, however now that some users have updated to Outlook 2010 the appointment retrieval is pulling back incorrect appointments along with the correct ones falling within the specified date range. The additional incorrect appointments being retrieved always appear to be recurring appointments. I was wondering if this is a known bug and if so what exactly is happening that is causing these additional recurring appointments to come in? I'd rather not have to throw in a workaround where I step through the items after they have been restricted and remove the extra ones, when this functionality works fine with 2007. Note: I've not recompiled or updated any code when experiencing this issue, just running the old program. This is the spot in my code where appointments are being restricted. This is similar to the way advised in the following msdn link: http://msdn.microsoft.com/en-us/library/bb611267.aspx Microsoft.Office.Interop.Outlook.Items outlookItems = outlookMapiFolder.Items.Restrict( "[Start] >= '" + outlookImport.startDay.ToString("g") + "' AND [Start] <= '" + outlookImport.endDay.ToString("g") + "'"); outlookItems.Sort("[Start]", Type.Missing); outlookItems.IncludeRecurrences = true;

    Read the article

  • i m trying to return list<object> from webmethod but gives error

    - by girish
    System.InvalidOperationException: There was an error generating the XML document. --- System.InvalidOperationException: The type WebService.Property.Property_Users was not expected. Use the XmlInclude or SoapInclude attribute to specify types that are not known statically. at System.Xml.Serialization.XmlSerializationWriter.WriteTypedPrimitive(String name, String ns, Object o, Boolean xsiType) at Microsoft.Xml.Serialization.GeneratedAssembly.XmlSerializationWriter1.Write1_Object(String n, String ns, Object o, Boolean isNullable, Boolean needType) at Microsoft.Xml.Serialization.GeneratedAssembly.XmlSerializationWriter1.Write8_ArrayOfAnyType(Object o) at Microsoft.Xml.Serialization.GeneratedAssembly.ListOfObjectSerializer.Serialize(Object objectToSerialize, XmlSerializationWriter writer) at System.Xml.Serialization.XmlSerializer.Serialize(XmlWriter xmlWriter, Object o, XmlSerializerNamespaces namespaces, String encodingStyle, String id) --- End of inner exception stack trace --- at System.Xml.Serialization.XmlSerializer.Serialize(XmlWriter xmlWriter, Object o, XmlSerializerNamespaces namespaces, String encodingStyle, String id) at System.Xml.Serialization.XmlSerializer.Serialize(TextWriter textWriter, Object o, XmlSerializerNamespaces namespaces) at System.Xml.Serialization.XmlSerializer.Serialize(TextWriter textWriter, Object o) at System.Web.Services.Protocols.XmlReturnWriter.Write(HttpResponse response, Stream outputStream, Object returnValue) at System.Web.Services.Protocols.HttpServerProtocol.WriteReturns(Object[] returnValues, Stream outputStream) at System.Web.Services.Protocols.WebServiceHandler.WriteReturns(Object[] returnValues) at System.Web.Services.Protocols.WebServiceHandler.Invoke() public List<object> GetDataByModuleName(string ModuleName) { List<Property_Users> obj_UserList = new List<Property_Users>(); // performing some operation that add data to obj_UserList List < Object > myList = new List<object>(); return ConvertToObjectList<Property_Users>(obj_UserList); } public List<Object> ConvertToObjectList<N>(List<N> sourceList) { List<Object> result = new List<Object>(); foreach (N item in sourceList) { result.Add(item as Object); } return result; } [WebMethod] public List<object> GetDataByModuleName(string ModuleName) { List<object> obj_list = new List<object>(); obj_list = BAL_GeneralService.GetDataByModuleName(ModuleName); return obj_list; }

    Read the article

  • Problem while executing test case in VS2008 test project

    - by sukumar
    Hi all I have the situation as follows I have develpoed one test project in visual studio 2008 to test my target project. I was getting the following exception when i ran test case in my PC System.IO.FileNotFoundException: The specified module could not be found. (Exception from HRESULT: 0x8007007E) at System.Reflection.Assembly._nLoad(AssemblyName fileName, String codeBase, Evidence assemblySecurity, Assembly locationHint, StackCrawlMark& stackMark, Boolean throwOnFileNotFound, Boolean forIntrospection) at System.Reflection.Assembly.nLoad(AssemblyName fileName, String codeBase, Evidence assemblySecurity, Assembly locationHint, StackCrawlMark& stackMark, Boolean throwOnFileNotFound, Boolean forIntrospection) at System.Reflection.Assembly.InternalLoad(AssemblyName assemblyRef, Evidence assemblySecurity, StackCrawlMark& stackMark, Boolean forIntrospection) at System.Reflection.Assembly.InternalLoadFrom(String assemblyFile, Evidence securityEvidence, Byte[] hashValue, AssemblyHashAlgorithm hashAlgorithm, Boolean forIntrospection, StackCrawlMark& stackMark) at System.Reflection.Assembly.LoadFrom(String assemblyFile) at Microsoft.VisualStudio.TestTools.TestTypes.Unit.UnitTestExecuter.GetType(UnitTestElement unitTest, String type) at Microsoft.VisualStudio.TestTools.TestTypes.Unit.UnitTestExecuter.ResolveMethods(). but the same project runs successfully in my colleague PC. as per my Understanding System.IO.FileNotFoundException will occur in case of missing out the dlls. i checked up with dependency walker to trace out the missed dll.dependency walke traced out the following dlls 1)MFC90D.dll 2)mSvcr90d.dll 3)msvcp90d.dll i copied this dlls to C:\windows\system32 from Microsoft visual studio 9.0 dir and again i ran the dependency walker.this time dependency walker is able to open the given testproject dll with 0 errors .even then the same exception comes up when i ran the test. i got fed up with this. can any one tell why it is behaving as PC dependent.is there any thing that i still missing? any suggestion can be helpfull Thakns in Advance Sukumar i

    Read the article

  • Unit Testing Error - The unit test adapter failed to connect to the data source or to read the data

    - by michael.lukatchik
    I'm using VSTS 2K8 and I've set up a Unit Test Project. In it, I have a test class with a method that does a simple assertion. I'm using an Excel 2007 spreadsheet as my data source. My test method looks like this: [DataSource("System.Data.Odbc", "Dsn=Excel Files;dbq=|DataDirectory|\\MyTestData.xlsx;defaultdir=C:\\TestData;driverid=1046;maxbuffersize=2048;pagetimeout=5", "Sheet1", DataAccessMethod.Sequential)] [DeploymentItem("MyTestData.xlsx")] [TestMethod()] public void State_Value_Is_Set() { string expected = "MD"; string actual = TestContext.DataRow["State"] as string; Assert.AreEqual(expected, actual); } As indicated in the method decoration attributes, my Excel spreadsheet is on my local C:/ Drive. In it, the sheet where all of my data is located is named "Sheet1". I've copied the Excel spreadsheet into my project and I've set its Build Action = "Content" and I've set its Copy to Output Directory = "Copy if Newer". When trying to run this simple unit test, I receive the following error: The unit test adapter failed to connect to the data source or to read the data. For more information on troubleshooting this error, see "Troubleshooting Data-Driven Unit Tests" (http://go.microsoft.com/fwlink/?LinkId=62412) in the MSDN Library. Error details: ERROR [42S02] [Microsoft][ODBC Excel Driver] The Microsoft Office Access database engine could not find the object 'Sheet1'. Make sure the object exists and that you spell its name and the path name correctly. I've verified that the sheet name is spelled correctly (i.e. Sheet1) and I've verified that my data sources are set correctly. Web searches haven't turned up much at all. And I'm totally stumped. All help or input is appreciated!!!!

    Read the article

  • How can I find out why a website looks different when I upload it to IIS ?

    - by UXdesigner
    Good day... I've been working on a website project, that requires to be on a Microsoft IIS Web Server. It is HTML, pure HTML, with really nice CSS, web-standards, etc. I open this website using in my computer, using Firefox, IE 8.0, Safari, Google Chrome and it looks fine everywhere. But as I upload it to the Microsoft IIS server, it changes a few things. for example: the main menu, which is a navigation bar that has dropdowns, seems to change it's line-height for some reason, and it is bigger. Some <h3> or <h2> Alignment seems wrong as well... And the lines that are supposed to surround the photographs in the website (like a frame - dotted line) won't appear. But all the rest of the CSS is loading perfectly fine. I don't think it's a path problem as everything is loading fine. But this is making me look bad and it is very important to have this done as soon as possible. Can someone give me good suggestions on what to look at ? The IIS permissions seem fine. I'm not a big Microsoft fan...but I have to develop the website there. Also, I uploaded the site to my apache server and it worked wonders. I wish I could change the policies in this corporation, but I can't. Thank you so much for your kind help.

    Read the article

  • Binding to XMLDataProvider in Code Behind

    - by Robert Vernunft
    Hello, i have a problem moving a XMLDataprovider Binding with XPath from Xaml to code behind. Labels.xml <?xml version="1.0" encoding="utf-8" ?> <Labels> <btnOne Label="Button1"/> <btnTwo Label="Button2"/> </Labels> MainWindow.xaml <Window xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:d="http://schemas.microsoft.com/expression/blend/2008" xmlns:mc="http://schemas.openxmlformats.org/markup-compatibility/2006" mc:Ignorable="d" x:Class="bindings.MainWindow" Title="MainWindow" Height="350" Width="525"> <Window.Resources> <XmlDataProvider x:Key="XMLLabels" Source="Labels.xml" XPath="Labels"/> </Window.Resources> <Grid> <Button Content="{Binding Source={StaticResource XMLLabels}, XPath=btnOne/@Label}" Height="23" HorizontalAlignment="Left" Margin="12,12,0,276" Name="btnOne" Width="75" /> <Button Content="Button" Height="23" HorizontalAlignment="Left" Margin="93,12,0,276" Name="btnTwo" Width="75" Loaded="btnTwo_Loaded" /> </Grid> </Window> MainWindow.xaml.cs ... private void btnTwo_Loaded(object sender, RoutedEventArgs e) { String Type = sender.GetType().Name; if (Type == "Button") { Button btn = sender as Button; Binding label = new Binding("XMLBind"); XmlDataProvider xmlLabels = (XmlDataProvider)this.FindResource("XMLLabels"); label.Source = xmlLabels; label.XPath = "btnTwo/@Header"; btn.SetBinding(Button.ContentProperty, label); } } ... The binding to content of btnOne works as aspected "Button1". But btnTwo is set to an empty string. The Output shows no errors. Thanks for any advice.

    Read the article