  • Brownfield Support for OVMSS

    - by Owen Allen
    The area of virtualization saw quite a few enhancements with version 12.2. There's one particular virtualization enhancement that can make a big difference for a lot of people: support for brownfield Oracle VM Servers for SPARC. Brownfield refers to Oracle VM Servers for SPARC that were created outside of Ops Center. In older versions of Ops Center, you couldn't really do anything with them - Ops Center could only manage OVM Servers that it created. If you had OVM Servers outside of Ops Center, you'd have to recreate them if you wanted to manage them. In 12.2, though, this problem is cleared up. You can discover and manage OVM Servers for SPARC that you created outside of Ops Center, so long as the LDom Manager is running. When you discover the control domain, all of the logical domains are automatically discovered and managed and appear under the control domain in the Asset tree. If you want to use server pools and migrate the logical domains to a different Oracle VM Server for SPARC system, you'll need to move the metadata to a shared library and use shared Fibre Channel or iSCSI LUNs for the guest domain storage and add the server to a server pool. See the Oracle VM Server for SPARC chapter for more information.

    Read the article

  • Replication with AK8

    - by Steve Tunstall
    Hello folks, This came up today and I want to make sure it's clear. Remember the "deferred update" I spoke about in my "Upgrade to AK8" entry just a bit ago? It's important to understand that this deferred update changes the way replication works. It is necessary that systems with the deferred update applied only replicate with other systems that have also had this deferred update applied. So if you apply it, your system can NOT replicate with ANY other system that has NOT had it applied, even if that other system is running AK8!!! Got it??? Remember, we do have a new version of the 2011 code for the older systems that do not want to upgrade to AK8. This 2011.1.8 code ALSO HAS this same deferred update in it. So, if you upgrade your system to AK8, and then apply the deferred update, and you have another system running either 2011.1.8 or AK8, you can replicate with them again once they apply the deferred update for multiple initiator groups. Yes, even if you're not using LUNs. Here is what it looks like if you try. It will fail.

    Read the article

  • iSCSI targets don't appear after rescan

    - by asmr
    Hi everybody, I have an Equallogic 4000PS SAN box to which I have connected 2 x ESX 4.0.0 hosts sharing the LUNs. I have an older ESX 3.5 host which I want to setup to share the same LUNs. I have setup a vmkernel port with 2 NICs attached to 2 the iSCSI switch. When I perform an iSCSI software adapter rescan, it takes a long time and it doesn't find the targets. In the ESX-3.5 host's log file I find these messages: Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.394 cpu5:1039)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.394 cpu5:1039)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.394 cpu5:1039)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.397 cpu0:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.397 cpu0:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.397 cpu0:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.442 cpu1:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.442 cpu1:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.442 cpu1:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.874 cpu3:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.874 cpu3:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.874 cpu3:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.884 cpu4:1041)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.884 cpu4:1041)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.884 cpu4:1041)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.888 cpu3:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.888 cpu3:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.888 cpu3:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.042 cpu7:1039)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.042 cpu7:1039)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.042 cpu7:1039)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.044 cpu3:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.044 cpu3:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.044 cpu3:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.045 cpu4:1041)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.045 cpu4:1041)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.045 cpu4:1041)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.308 cpu3:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.309 cpu3:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.309 cpu3:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.598 cpu2:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.598 cpu2:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.598 cpu2:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.600 cpu7:1039)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.600 cpu7:1039)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.600 cpu7:1039)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Any ideas what the problem is?

    Read the article

  • 4.8M wasn't enough so we went for 5.055M tpmc with Unbreakable Enterprise Kernel r2 :-)

    - by wcoekaer
    We released a new set of benchmarks today. One is an updated tpc-c from a few months ago where we had just over 4.8M tpmc at $0.98 and we just updated it to go to 5.05M and $0.89. The other one is related to Java Middleware performance. You can find the press release here. Now, I don't want to talk about the actual relevance of the benchmark numbers, as I am not in the benchmark team. I want to talk about why these numbers and these efforts, unrelated to what they mean to your workload, matter to customers. The actual benchmark effort is a very big, long, expensive undertaking where many groups work together as a big virtual team. Having the virtual team be within a single company of course helps tremendously... We already start with a very big server setup with tons of storage, many disks, lots of ram, lots of cpu's, cores, threads, large database setups. Getting the whole setup going to start tuning, by itself, is no easy task, but then the real fun starts with tuning the system for optimal performance -and- stability. A benchmark is not just revving an engine at high rpm, it's actually hitting the circuit. The tests require long runs, require surviving availability tests, such as surviving crashes -and- recovery under load. In the TPC-C example, the x4800 system had 4TB ram, 160 threads (8 sockets, hyperthreaded, 10 cores/socket), tons of storage attached, tons of luns visible to the OS. flash storage, non flash storage... many things at high scale that all have to be perfectly synchronized. During this process, we find bugs, we fix bugs, we find performance issues, we fix performance issues, we find interesting potential features to investigate for the future, we start new development projects for future releases and all this goes back into the products. As more and more customers, for Oracle Linux, are running larger and larger, faster and faster, more mission critical, higher available databases..., these things are just absolutely critical. Unrelated to what anyone's specific opinion is about tpc-c or tpc-h or specjenterprise etc, there is a ton of effort that the customer benefits from. All this work makes Oracle Linux and/or Oracle Solaris better platforms. Whether it's faster, more stable, more scalable, more resilient. It helps. Another point that I always like to re-iterate around UEK and UEK2 : we have our kernel source git repository online. Complete changelog of the mainline kernel, and our changes, easy to pull, easy to dissect, easy to know what went in when, why and where. No need to go log into a website and manually click through pages to hopefully discover changes or patches. No need to untar 2 tar balls and run a diff.

    Read the article

  • VMWare ESX, storage over 2TB

    - by Phliplip
    Hi, First of, i'm a webdeveloper and my server experience lies in setting up FreeBSD servers for webserver. I'm working on a project for at photographer, and i'm hired to develop a new online photo ordering system - where user of course can view their photos :) They have a massive need of storage, thus we have bought a HP G6 and 8x1TB SATA HDD. Our plan is to install VMWare ESX 4.0, running multiple virtual machines; FreeBSD 8 for webserver and some windows servers. Allready done that. Then mount one big storage to the BSD, and share it through Samba to the WinServers. The raid is set up with an array of 2x 1TB to handle the VMs. And the rest is setup as 3 2x1TB to handle the photo-data. Thus 2.73TB for photo-data (the raids are 1+0). Now if we add a datastore in the ESX and add the 3 LUNs we can get a datastore of 2.74TB. But i don't se how i can add this datastore direct to the VM. Only the BSD VM needs access to this. Only way is to create a VirtualDisk, with a max of 2TB (8MB blocksize). This is because the datastore where we save the virtualdisk has a maximum filesize of 2TB. Then add it as a harddisk to the BSD VM. In the 'Add Harddisk' pane for the VM, i see an option for Raw Disk Management. I think this is to access the datastore or the raid directly. Only problem is that its greyed out! Can i access the datastorage directly from the BSD? Without creating and adding virtualdisk.

    Read the article

  • I need advice about iscsi + zfs(or ntfs) + windows 2008 clustering

    - by Fatih
    I want to setup a storage farm with iSCSI. I have 2 cluster node machine, 1 iscsi target machine that has 8TB installed as RAID 10. The capacity is now 8TB, but I'll upgrade the capacity in future. Let's say, I installed clusters as file server, and I connected these servers to iscsi target, then I shared 8TB capacity as an only folder to the windows users. Users now see only a folder whose capacity is 8TB. But if I want to add another 8TB to expand the main capacity, the users must not see the second folder for this new 8 TB. The users must see only a folder as before, but this time this folder's capacity expanded to 16TB. And so on, if I add another 8TB, the users must deal with only a folder. For this purpose, I've learnt that ZFS can expand its size without a problem. So if I use ZFS as a file system on iSCSI luns, how can the cluster machines see the ZFS. Because the cluster machines have windows 2008. Is there another way to expand the size of shared folder without a problem? Does ntfs support it?

    Read the article

  • MultiPath configuration on RHEL5 and Clariion CX-300

    - by Kamil Z
    I have problem with discovering my FC-connected CX-300 storage. Frankly speaking I'm complete novice in FibreChannel, so step by step explanation would be appreciated. My configuration consist of two IBM HS20 blades with RHEL5.4 on board and 2x Qlogic ISP2422-based 4Gb Fibre Channel HBAs on each blade. As a FC switch there are two Brocades built in BladeCenter Chassis, and finally there is EMC Clariion CX-300. CX300, and Brocade switches should be configured properly, because they were working fine with previous configuration, which main defference was RHEL3 instead RHEL5.4 Below there is my output from several usefull commands: #lspci | grep Fibre 06:01.0 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) 06:01.1 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) #lsmod | grep qla qla2xxx 1084741 0 scsi_transport_fc 37577 1 qla2xxx scsi_mod 141717 10 scsi_dh,qla2xxx,sg,scsi_transport_fc,usb_storage,libata,mptspi,mptscsih,scsi_transport_spi,sd_mod #cat /proc/scsi/scsi Attached Devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: LSILOGIC Model: 1030 IM IM Rev: 1000 Type: Direct-Access ANSI SCSI revision: 02 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 I'd followed instructions from this site (editing /etc/multipath.conf), but i failed after multipath -ll - the output was empty. Do you have any suggestions about discovering FC Connected LUNs in such configuration?

    Read the article

  • P2v options within a hyper-v environment.

    - by tony roth
    I have a server that san boots that I want to p2v. I have many options disk2vhd, scvmm etc but I was thinking about cloning the lun (flexclone, netapp) presenting it to my hyper-v r2 server. Within the hv manager do a create new disk then have it copy the cloned lun to a vhd file. Then do the bcdedit\bootsect stuff to it. Should work right? I'm also curious if anybodys booting vhd's that are on bootable luns? I've booted native vhd's just fine was just curious about the running them off a bootable lun. I think that this has quite a few advantages like instant p2v etc.. any thoughts on this? hmm dang as I was typing this I realized that I should not use the hv manager new disk copy routine, I should just disk2vhd the mounted lun. This has advantages in that it should be a lot faster!! discovered that disk2vhd may be flaky, crashed the first time I ran it! thanks

    Read the article

  • Samba 3.5 Shadow Copy for Windows 7

    - by Prashanth Sundaram
    Over the past several days I have been trying to get the shadow to work with samba but haven’t been successful. Can someone check below config and let me know if I am missing something? We are using Equallogic SAN and iSCSI LUNS to mount volumes. I can cleanly access samba shares on Windows 7 clients but just not shadow copy. I have referred the official how-to but couldn’t get it to work. I see these messages in the logs. Any help is deeply appreciated. [2012/10/31 12:20:53.549863, 0] smbd/nttrans.c:2170(call_nt_transact_ioctl) FSCTL_GET_SHADOW_COPY_DATA: connectpath /fs/test-01, failed. [2012/10/31 12:21:13.887198, 0] modules/vfs_shadow_copy2.c:734(shadow_copy2_get_shadow_copy2_data) shadow:snapdir not found for /fs/test-01 in get_shadow_copy_data [2012/10/31 12:21:13.887265, 0] smbd/nttrans.c:2170(call_nt_transact_ioctl) FSCTL_GET_SHADOW_COPY_DATA: connectpath /fs/test-01, failed. == Samba pkgs == samba-3.5.10-116.el6_2.x86_64 samba-common-3.5.10-116.el6_2.x86_64 samba-winbind-clients-3.5.10-116.el6_2.x86_64 samba-client-3.5.10-116.el6_2.x86_64 === df –h == First is the iSCSI LUN and 2 others are snapshots. /dev/mapper/eql-0-fs-test01 5.0G 2.3G 2.5G 48% /fs/test-01 /dev/mapper/eql-2-0+fs-test01 5.0G 2.3G 2.5G 48% /fs/test-01/@GMT-2012.10.26-17.32.42/fs/test-01 (SNAPSHOT-1) /dev/mapper/eql-d-0+fs-test01 5.0G 2.3G 2.5G 48% /fs/test-01/@GMT-2012.10.31-11.52.42/fs/test-01 (SNAPSHOT- 2) ===/etc/samba/smb.conf === [global] workgroup = DOMAIN server string = Samba Server Version %v security = ads realm = DOMAIN.CORP encrypt passwords = yes guest account = nobody map to guest = bad uid log file = /var/log/samba/%m.log domain master = no local master = no preferred master = no os level = 0 load printers = no show add printer wizard = no printable = no printcap name = /dev/null disable spoolss = yes follow symlinks = yes wide links = yes unix extensions = no [test] comment = Test Directories path = /fs/test-01 vfs objects = shadow_copy2 #shadow_copy2: sort = desc #shadow: localtime = yes #shadow: snapdir = /fs/test-01/test #shadow: basedir = /fs/test-01 guest ok = yes writeable = yes map archive = no force create mode = 0660 force directory mode = 2770 inherit owner = yes inherit permissions = yes All feedback is welcome. Thanks!

    Read the article

  • Booting VM Directly from iSCSI (or FC) in Hyper-V R2

    - by tony roth
    I have a server that san boots that I want to p2v. I have many options disk2vhd, scvmm etc but I was thinking about cloning the lun (flexclone, netapp) presenting it to my hyper-v r2 server. Within the hv manager do a create new disk then have it copy the cloned lun to a vhd file. Then do the bcdedit\bootsect stuff to it. Should work right? I'm also curious if anybodys booting vhd's that are on bootable luns? I've booted native vhd's just fine was just curious about the running them off a bootable lun. I think that this has quite a few advantages like instant p2v etc.. any thoughts on this? hmm dang as I was typing this I realized that I should not use the hv manager new disk copy routine, I should just disk2vhd the mounted lun. This has advantages in that it should be a lot faster!! discovered that disk2vhd may be flaky, crashed the first time I ran it! thanks

    Read the article

  • DAS vs SAN storage for serving 2 to 4 nodes

    - by Luke404
    We currently have 4 Linux nodes with local storage, arranged in two active/passive pairs with storage mirrored using DRBD, running virtual machines (actually using Xen Hypervisor) for typical hosting workloads (mail, web, a couple VPS, etc.). We're approaching the (presumed) maximum IOPS of those servers, and we're planning to migrate to an external storage solution with two active nodes, with capacity for up to four active nodes. Since we're an all-Dell shop I've done some research and found the MD3200 / MD3200i products should be the ones we're looking for. We are pretty sure we won't be attaching more than 4 hosts on a single storage and I'm wondering if there is any clear advantage for one or the other. In theory I should be able to attach 4 SAS hosts to a single MD3200 (single links on a single controller MD3200, or dual redundant SAS links from each host to a dual-controller MD3200), or 4 iSCSI hosts to a single MD3200i (directly on its 4 GigE ports without any switch, again with dual links for the dual controller option). Both setups should let us implement live VM migration since all hosts can access all the LUNs at the same time, and also some shared filesystem like GFS2 or OCFS2. Also, both setups should allow full redundancy of the whole system (assuming dual controllers in the storage). One difference I can see is that the DAS solution is actually limited to 4 hosts while the iSCSI one should be able to grow to more hosts (adding two GigE switches to the mix). One point for the iSCSI solution is that it would allow us to start out with our current nodes and upgrade them at a later time (we can't add other SAS controllers, but they already have 4 GigE ports each). With the right (iSCSI|SAS) controllers I should be able to connect diskless nodes and boot them off the external storage which I think is a good thing (get rid of any local storage). On the other hand, I would have thought the SAS one to be cheaper but it seems like an MD3200 actually costs a little less than an MD3200i (?) (please note: I've used Dell gear in my examples since that's what we're looking for but I assume the same goes with other vendors) I would like to know if my assumptions above are correct, and if I'm missing any important difference between the two setups.

    Read the article

  • Why your Netapp is so slow...

    - by Darius Zanganeh
    Have you ever wondered why your Netapp FAS box is slow and doesn't perform well at large block workloads?  In this blog entry I will give you a little bit of information that will probably help you understand why it’s so slow, why you shouldn't use it for applications that read and write in large blocks like 64k, 128k, 256k ++ etc..  Of course since I work for Oracle at this time, I will show you why the ZS3 storage boxes are excellent choices for these types of workloads. Netapp’s Fundamental Problem The fundamental problem you have running these workloads on Netapp is the backend block size of their WAFL file system.  Every application block on a Netapp FAS ends up in a 4k chunk on a disk. Reference:  Netapp TR-3001 Whitepaper Netapp has proven this lacking large block performance fact in at least two different ways. They have NEVER posted an SPC-2 Benchmark yet they have posted SPC-1 and SPECSFS, both recently. In 2011 they purchased Engenio to try and fill this GAP in their portfolio. Block Size Matters So why does block size matter anyways?  Many applications use large block chunks of data especially in the Big Data movement.  Some examples are SAS Business Analytics, Microsoft SQL, Hadoop HDFS is even 64MB! Now let me boil this down for you.  If an application such MS SQL is writing data in a 64k chunk then before Netapp actually writes it on disk it will have to split it into 16 different 4k writes and 16 different disk IOPS.  When the application later goes to read that 64k chunk the Netapp will have to again do 16 different disk IOPS.  In comparison the ZS3 Storage Appliance can write in variable block sizes ranging from 512b to 1MB.  So if you put the same MSSQL database on a ZS3 you can set the specific LUNs for this database to 64k and then when you do an application read/write it requires only a single disk IO.  That is 16x faster!  But, back to the problem with your Netapp, you will VERY quickly run out of disk IO and hit a wall.  Now all arrays will have some fancy pre fetch algorithm and some nice cache and maybe even flash based cache such as a PAM card in your Netapp but with large block workloads you will usually blow through the cache and still need significant disk IO.  Also because these datasets are usually very large and usually not dedupable they are usually not good candidates for an all flash system.  You can do some simple math in excel and very quickly you will see why it matters.  Here are a couple of READ examples using SAS and MSSQL.  Assume these are the READ IOPS the application needs even after all the fancy cache and algorithms.   Here is an example with 128k blocks.  Notice the numbers of drives on the Netapp! Here is an example with 64k blocks You can easily see that the Oracle ZS3 can do dramatically more work with dramatically less drives.  This doesn't even take into account that the ONTAP system will likely run out of CPU way before you get to these drive numbers so you be buying many more controllers.  So with all that said, lets look at the ZS3 and why you should consider it for any workload your running on Netapp today.  ZS3 World Record Price/Performance in the SPC-2 benchmark ZS3-2 is #1 in Price Performance $12.08ZS3-2 is #3 in Overall Performance 16,212 MBPS Note: The number one overall spot in the world is held by an AFA 33,477 MBPS but at a Price Performance of $29.79.  A customer could purchase 2 x ZS3-2 systems in the benchmark with relatively the same performance and walk away with $600,000 in their pocket.

    Read the article

  • ESXi with software iSCSI

    - by jharley
    Has anyone had any luck using the swiSCSI driver on ESXi? Following the instructions from VMWare.com I get to the point where I have the iSCSI HBA showing up but no LUNs/targets are showing up. The iSCSI target is running on Solaris 10 update 5 and works with other initiators fine. The ESXi initiator (from the logs) sees the targets but just logs in and out of them every 2 - 5 seconds. We're using unauthenticated discovery, and over and over in /var/log/messages I see: iSCSI: bus 0 target 0 trying to establish session 0xb203f90 to portal 0, address 10.1.100.9 port 3260 group 1 iSCSI: bus 0 target 0 establish session 0xb203f90 #4848 to port 0, address 10.1.100.9 port 3260 group 1, alias data/ESXi iSCSI: session 0xb203f90 dropping after receiving unexpected opcode 0x60 iSCSI: session 0xb203f90 to data/ESXi dropped iSCSI: session 0xb203f90 to data/ESXi waiting 2 seconds before next login attempt The only other thing that seems out of wack is that my 'Recent Tasks' pane keeps filling with 'Browse Diagnostic Manager' events and /var/log/vmware/hostd.log is filled with messages like this up to two times per second: [2008-09-19 16:05:57.901 'TaskManager' 196621 info] Task Created: haTask-ha-host-vim.DiagnosticManager.browser-776 [2008-09-19 16:05:57.094 'TaskManager' 196621 info] Task Completed: haTask-ha-host-vim.DiagnosticManager.browser-766 Any help would be appreciated.

    Read the article

  • Lock ups, crashing, transferring files using TrueCrypt with iSCSI

    - by Anthony
    I have looked into this error and it seems that it hasn't been discussed yet - or at least I can't find any information relating. I'm having issues transferring files, usually larger files over a couple of hundred MB. Here is the setup: QNAP 410 as iSCSI Target with multiple LUNs. (CRC is turned on (Data Digest and Header Digest) Server 2003 with iSCSI Initiator version 2.08 - build 3825 (I'm copying files from anothe machine to shares on Server 2003 = into TrueCrypt volume ergo onto the NAS) I have mounted the LUN and formatted it with TrueCrypt using NTFS (Full format, not a quick one). What happens is some files, mainly RAR/Compressed files, appear as if they copy but fail. I've tested this in a number of ways and can repeat the process every time. So I thought to check transfer over iSCSI without TrueCrypt in between, a plain NTFS format - no problem at all. So it would seem TrueCrypt is at least part of the problem here. I haven't tried copying directly from the server yet, I will try that. I also haven't tried it without CRC but fail to see how that would affect this. I will update with my findings later. In the meantime does anyone have any ideas as to what could be wrong? Thanks for your time. Update: I copied a set of files, the ones I was having issues with, to the server then from there I copied those into two places within the TrueCrypt volume (Mounted on the NAS). A seperate directory create in the root of the volume The same initial directory I was using in the first instance Both worked fine. So it now seems clear that this is a link between TrueCrypt, iSCSI and Windows Shares. I say this because I originally setup the whole system using TrueCrypt volume files, not iSCSI. I changed it as it didn't suit my requirements - day wasted as well. While I had this setup though I copied my entire file set to the volume files and all files copied without error - over the network, from a pc, to the server where TrueCrypt had the volume files mounted from the NAS. I didn't bother turning off CRC on the iSCSI system as I highly doubt that is the cause in light of this finding. So any ideas?

    Read the article

  • What to leave when you're leaving

    - by BuckWoody
    There's already a post on this topic - sort of. I read this entry, where the author did a good job on a few steps, but I found that a few other tips might be useful, so if you want to check that one out and then this post, you might be able to put together your own plan for when you leave your job.  I once took over the system administrator (of which the Oracle and SQL Server servers were a part) at a mid-sized firm. The outgoing administrator had about a two- week-long scheduled overlap with me, but was angry at the company and told me "hey, I know this is going to be hard on you, but I want them to know how important I was. I'm not telling you where anything is or what the passwords are. Good luck!" He then quit that day. It took me about three days to find all of the servers and crack the passwords. Yes, the company tried to take legal action against the guy and all that, but he moved back to his home country and so largely got away with it. Obviously, this isn't the way to leave a job. Many of us have changed jobs in the past, and most of us try to be very professional about the transition to a new team, regardless of the feelings about a particular company. I've been treated badly at a firm, but that is no reason to leave a mess for someone else. So here's what you should put into place at a minimum before you go. Most of this is common sense - which of course isn't very common these days - and another good rule is just to ask yourself "what would I want to know"? The article I referenced at the top of this post focuses on a lot of documentation of the systems. I think that's fine, but in actuality, I really don't need that. Even with this kind of documentation, I still perform a full audit on the systems, so in the end I create my own system documentation. There are actually only four big items I need to know to get started with the systems: 1. Where is everything/everybody?The first thing I need to know is where all of the systems are. I mean not only the street address, but the closet or room, the rack number, the IU number in the rack, the SAN luns, all that. A picture here is worth a thousand words, which is why I really like Visio. It combines nice graphics, full text and all that. But use whatever you have to tell someone the physical locations of the boxes. Also, tell them the physical location of the folks in charge of those boxes (in case you aren't) or who share that responsibility. And by "where" in this case, I mean names and phones.  2. What do they do?For both the servers and the people, tell them what they do. If it's a database server, detail what each database does and what application goes to that, and who "owns" that application. In my mind, this is one of hte most important things a Data Professional needs to know. In the case of the other administrtors or co-owners, document each person's responsibilities.   3. What are the credentials?Logging on/in and gaining access to the buildings are things that the new Data Professional will need to do to successfully complete their job. This means service accounts, certificates, all of that. The first thing they should do, of course, is change the passwords on all that, but the first thing they need is the ability to do that!  4. What is out of the ordinary?This is the most tricky, and perhaps the next most important thing to know. Did you have to use a "special" driver for that video card on server X? Is the person that co-owns an application with you mentally unstable (like me) or have special needs, like "don't talk to Buck before he's had coffee. Nothing will make any sense"? Do you have service pack requirements for a specific setup? Write all that down. Anything that took you a day or longer to make work is probably a candidate here. This is my short list - anything you care to add? Share this post: email it! | bookmark it! | digg it! | reddit! | kick it! | live it!

    Read the article

  • Windows 2008 Unknown Disks

    - by Ailbe
    I have a BL460c G7 blade server with OS Windows 2008 R2 SP1. This is a brand new C7000 enclosure, with FlexFabric interconnects. I got my FC switches setup and zoned properly to our Clariion CX4, and can see all the hosts that are assigned FCoE HBAs on both paths in both Navisphere and in HP Virtual Connect Manager. So I went ahead and created a storage group for a test server, assigned the appropriate host, assigned the LUN to the server. So far so good, log onto server and I can see 4 unknown disks.... No problem, I install MS MPIO, no luck, can't initialize the disks, and the multiple disks don't go away. Still no problem, I install PowerPath version 5.5 reboot. Now I see 3 disks. One is initialized and ready to go, but I still have 2 disks that I can't initialize, can't offline, can't delete. If I right click in storage manager and go to properties I can see that the MS MPIO tab, but I can't make a path active. I want to get rid of these phantom disks, but so far nothing is working and google searches are showing up some odd results, so obviously I'm not framing my question right. I thought I'd ask here real quick. Does anyone know a quick way to get rid of these unknown disks. Another question, do I need the MPIO feature installed if I have PowerPath installed? This is my first time installing Windows 2008 R2 in this fashion and I'm not sure if that feature is needed or not right now. So some more information to add to this. It seems I'm dealing with more of a Windows issue than anything else. I removed the LUN from the server, uninstalled PowerPath completely, removed the MPIO feature from the server, and rebooted twice. Now I am back to the original 4 Unknown Disks (plus the local Disk 0 containing the OS partition of course, which is working fine) I went to diskpart, I could see all 4 Unknown disks, I selected each disk, ran clean (just in case i'd somehow brought them online previously as GPT and didn't realize it) After a few minutes I was no longer able to see the disks when I ran list disk. However, the disks are still in Disk Management. When I try and offline the disks from Disk Management I get an error: Virtual Disk Manager - The system cannot find the file specified. Accompanied by an error in System Event Logs: Log Name: System Source: Virtual Disk Service Date: 6/25/2012 4:02:01 PM Event ID: 1 Task Category: None Level: Error Keywords: Classic User: N/A Computer: hostname.local Description: Unexpected failure. Error code: 2@02000018 Event Xml: 1 2 0 0x80000000000000 4239 System hostname.local 2@02000018 I feel sure there is a place I can go in the Registry to get rid of these, I just can't recall where and I am loathe to experiement. So to recap, there are currently no LUNS attached at all, I still have the phantom disks, and I'm getting The system cannot find the file specified from Virtual Disk Manager when I try to take them offline. Thanks!

    Read the article

  • Clustering Basics and Challenges

    - by Karoly Vegh
    For upcoming posts it seemed to be a good idea to dedicate some time for cluster basic concepts and theory. This post misses a lot of details that would explode the articlesize, should you have questions, do not hesitate to ask them in the comments.  The goal here is to get some concepts straight. I can't promise to give you an overall complete definitions of cluster, cluster agent, quorum, voting, fencing, split brain condition, so the following is more of an explanation. Here we go. -------- Cluster, HA, failover, switchover, scalability -------- An attempted definition of a Cluster: A cluster is a set (2+) server nodes dedicated to keep application services alive, communicating through the cluster software/framework with eachother, test and probe health status of servernodes/services and with quorum based decisions and with switchover/failover techniques keep the application services running on them available. That is, should a node that runs a service unexpectedly lose functionality/connection, the other ones would take over the and run the services, so that availability is guaranteed. To provide availability while strictly sticking to a consistent clusterconfiguration is the main goal of a cluster.  At this point we have to add that this defines a HA-cluster, a High-Availability cluster, where the clusternodes are planned to run the services in an active-standby, or failover fashion. An example could be a single instance database. Some applications can be run in a distributed or scalable fashion. In the latter case instances of the application run actively on separate clusternodes serving servicerequests simultaneously. An example for this version could be a webserver that forwards connection requests to many backend servers in a round-robin way. Or a database running in active-active RAC setup.  -------- Cluster arhitecture, interconnect, topologies -------- Now, what is a cluster made of? Servers, right. These servers (the clusternodes) need to communicate. This of course happens over the network, usually over dedicated network interfaces interconnecting all the clusternodes. These connection are called interconnects.How many clusternodes are in a cluster? There are different cluster topologies. The most simple one is a clustered pair topology, involving only two clusternodes:  There are several more topologies, clicking the image above will take you to the relevant documentation. Also, to answer the question Solaris Cluster allows you to run up to 16 servers in a cluster. Where shall these clusternodes be placed? A very important question. The right answer is: It depends on what you plan to achieve with the cluster. Do you plan to avoid only a server outage? Then you can place them right next to eachother in the datacenter. Do you need to avoid DataCenter outage? In that case of course you should place them at least in different fire zones. Or in two geographically distant DataCenters to avoid disasters like floods, large-scale fires or power outages. We call this a stretched- or campus cluster, the clusternodes being several kilometers away from eachother. To cover really large distances, you probably need to move to a GeoCluster, which is a different kind of animal.  What is a geocluster? A Geographic Cluster in Solaris Cluster terms is actually a metacluster between two, separate (locally-HA) clusters.  -------- Cluster resource types, agents, resources, resource groups -------- So how does the cluster manage my applications? The cluster needs to start, stop and probe your applications. If you application runs, the cluster needs to check regularly if the application state is healthy, does it respond over the network, does it have all the processes running, etc. This is called probing. If the cluster deems the application is in a faulty state, then it can try to restart it locally or decide to switch (stop on node A, start on node B) the service. Starting, stopping and probing are the three actions that a cluster agent does. There are many different kinds of agents included in Solaris Cluster, but you can build your own too. Examples are an agent that manages (mounts, moves) ZFS filesystems, or the Oracle DB HA agent that cares about the database, or an agent that moves a floating IP address between nodes. There are lots of other agents included for Apache, Tomcat, MySQL, Oracle DB, Oracle Weblogic, Zones, LDoms, NFS, DNS, etc.We also need to clarify the difference between a cluster resource and the cluster resource group.A cluster resource is something that is managed by a cluster agent. Cluster resource types are included in Solaris cluster (see above, e.g. HAStoragePlus, HA-Oracle, LogicalHost). You can group cluster resources into cluster resourcegroups, and switch these groups together from one node to another. To stick to the example above, to move an Oracle DB service from one node to another, you have to switch the group between nodes, and the agents of the cluster resources in the group will do the following:  On node A Shut down the DB Unconfigure the LogicalHost IP the DB Listener listens on unmount the filesystem   Then, on node B: mount the FS configure the IP  startup the DB -------- Voting, Quorum, Split Brain Condition, Fencing, Amnesia -------- How do the clusternodes agree upon their action? How do they decide which node runs what services? Another important question. Running a cluster is a strictly democratic thing.Every node has votes, and you need the majority of votes to have the deciding power. Now, this is usually no problem, clusternodes think very much all alike. Still, every action needs to be governed upon in a productive system, and has to be agreed upon. Agreeing is easy as long as the clusternodes all behave and talk to eachother over the interconnect. But if the interconnect is gone/down, this all gets tricky and confusing. Clusternodes think like this: "My job is to run these services. The other node does not answer my interconnect communication, it must be down. I'd better take control and run the services!". The problem is, as I have already mentioned, clusternodes very much think alike. If the interconnect is gone, they all assume the other node is down, and they all want to mount the data backend, enable the IP and run the database. Double IPs, double mounts, double DB instances - now that is trouble. Also, in a 2-node cluster they both have only 50% of the votes, that is, they themselves alone are not allowed to run a cluster.  This is where you need a quorum device. According to Wikipedia, the "requirement for a quorum is protection against totally unrepresentative action in the name of the body by an unduly small number of persons.". They need additional votes to run the cluster. For this requirement a 2-node cluster needs a quorum device or a quorum server. If the interconnect is gone, (this is what we call a split brain condition) both nodes start to race and try to reserve the quorum device to themselves. They do this, because the quorum device bears an additional vote, that could ensure majority (50% +1). The one that manages to lock the quorum device (e.g. if it's an FC LUN, it SCSI reserves it) wins the right to build/run a cluster, the other one - realizing he was late - panics/reboots to ensure the cluster config stays consistent.  Losing the interconnect isn't only endangering the availability of services, but it also endangers the cluster configuration consistence. Just imagine node A being down and during that the cluster configuration changes. Now node B goes down, and node A comes up. It isn't uptodate about the cluster configuration's changes so it will refuse to start a cluster, since that would lead to cluster amnesia, that is the cluster had some changes, but now runs with an older cluster configuration repository state, that is it's like it forgot about the changes.  Also, to ensure application data consistence, the clusternode that wins the race makes sure that a server that isn't part of or can't currently join the cluster can access the devices. This procedure is called fencing. This usually happens to storage LUNs via SCSI reservation.  Now, another important question: Where do I place the quorum disk?  Imagine having two sites, two separate datacenters, one in the north of the city and the other one in the south part of it. You run a stretched cluster in the clustered pair topology. Where do you place the quorum disk/server? If you put it into the north DC, and that gets hit by a meteor, you lose one clusternode, which isn't a problem, but you also lose your quorum, and the south clusternode can't keep the cluster running lacking the votes. This problem can't be solved with two sites and a campus cluster. You will need a third site to either place the quorum server to, or a third clusternode. Otherwise, lacking majority, if you lose the site that had your quorum, you lose the cluster. Okay, we covered the very basics. We haven't talked about virtualization support, CCR, ClusterFilesystems, DID devices, affinities, storage-replication, management tools, upgrade procedures - should those be interesting for you, let me know in the comments, along with any other questions. Given enough demand I'd be glad to write a followup post too. Now I really want to move on to the second part in the series: ClusterInstallation.  Oh, as for additional source of information, I recommend the documentation: http://docs.oracle.com/cd/E23623_01/index.html, and the OTN Oracle Solaris Cluster site: http://www.oracle.com/technetwork/server-storage/solaris-cluster/index.html

    Read the article

  • Failure connecting to Dell MD3200i from XenServer 6.2 pool

    - by Tom Sparrow
    This question also asked at Citrix Forums http://forums.citrix.com/thread.jspa?threadID=332289 I have a MD3200i that is currently working fine with my Xen5.6 pool, but I cannot get a connection to the new 6.2 pool to work. I previously had a problem with a 6.0 upgrade (which is why the old pool is still on 5.6), but rolled back rather than fix it as it wasn't urgent at the time. This install is on new machines - I tried 6.1 first (which had the same problems) then 6.2 was released the second day after installation so I switched to that. I've not installed anything from the Dell resource DVD at this point - I can't find anything saying I should, and everything I have read suggests it shouldn't be necessary. I can ping all 8 ip addresses from both servers in the pool, iscsiadm -m discovery works fine, I can login to the nodes and iscsiadm reports the sessions active correctly. I've added the required sections to multipath.conf, but multipath -ll reports DM multipath kernel driver not loaded immediately after boot. The following is a log of a test session immediately after boot. root@xen3 ~]# iscsiadm -m node --loginall=all Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.101,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.101,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.104,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.102,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.103,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.104,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.102,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.103,3260] Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.101,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.101,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.104,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.102,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.103,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.104,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.102,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.103,3260]: successful [root@xen3 ~]# iscsiadm -m session tcp: [1] 192.168.130.101:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [2] 192.168.131.101:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [3] 192.168.131.104:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [4] 192.168.131.102:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [5] 192.168.130.103:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [6] 192.168.130.104:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [7] 192.168.130.102:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [8] 192.168.131.103:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 [root@xen3 ~]# service multipathd restart ok Stopping multipathd daemon: [ OK ] Starting multipathd daemon: [ OK ] [root@xen3 ~]# multipath Jul 04 09:58:47 | DM multipath kernel driver not loaded Jul 04 09:58:47 | DM multipath kernel driver not loaded [root@xen3 ~]# multipath -ll Jul 04 09:59:03 | DM multipath kernel driver not loaded Jul 04 09:59:03 | DM multipath kernel driver not loaded [ root@xen3 ~]# modprobe dm_multipath [root@xen3 ~]# multipath Jul 04 10:19:50 | 36b8ca3a0e7024800194a0bd11891cd14: ignoring map create: 1Dell_Internal_Dual_SD_0123456789AB undef Dell,Internal Dual SD size=1.9G features='0' hwhandler='0' wp=undef `-+- policy='round-robin 0' prio=1 status=undef `- 7:0:0:0 sdb 8:16 undef ready running [root@xen3 ~]# multipath -ll 1Dell_Internal_Dual_SD_0123456789AB dm-1 Dell,Internal Dual SD size=1.9G features='0' hwhandler='0' wp=rw `-+- policy='round-robin 0' prio=1 status=enabled `- 7:0:0:0 sdb 8:16 active ready running [root@xen3 ~]# iscsiadm -m session tcp: [1] 192.168.130.101:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [2] 192.168.131.101:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [3] 192.168.131.104:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [4] 192.168.131.102:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [5] 192.168.130.103:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [6] 192.168.130.104:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [7] 192.168.130.102:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [8] 192.168.131.103:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 [root@xen3 ~]# dmesg | tail -n 50 [ 1161.881010] sd 8:0:0:0: [sdf] Unhandled error code [ 1161.881013] sd 8:0:0:0: [sdf] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1161.881017] sd 8:0:0:0: [sdf] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1161.881024] end_request: I/O error, dev sdf, sector 0 [ 1161.881031] Buffer I/O error on device sdf, logical block 0 [ 1161.881045] sd 15:0:0:0: [sdi] Unhandled error code [ 1161.881048] sd 15:0:0:0: [sdi] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1161.881052] sd 15:0:0:0: [sdi] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1161.881058] end_request: I/O error, dev sdi, sector 0 [ 1161.881065] Buffer I/O error on device sdi, logical block 0 [ 1161.881122] sd 9:0:0:0: [sdg] Unhandled error code [ 1161.881124] sd 9:0:0:0: [sdg] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1161.881126] sd 9:0:0:0: [sdg] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1161.881132] end_request: I/O error, dev sdg, sector 0 [ 1161.881140] Buffer I/O error on device sdg, logical block 0 [ 1168.220951] connection6:0: ping timeout of 15 secs expired, recv timeout 10, last rx 84060, last ping 85060, now 86560 [ 1168.220957] connection7:0: ping timeout of 15 secs expired, recv timeout 10, last rx 84060, last ping 85060, now 86560 [ 1168.220967] connection7:0: detected conn error (1011) [ 1168.220969] connection4:0: ping timeout of 15 secs expired, recv timeout 10, last rx 84060, last ping 85060, now 86560 [ 1168.220973] connection4:0: detected conn error (1011) [ 1168.220975] connection3:0: ping timeout of 15 secs expired, recv timeout 10, last rx 84060, last ping 85060, now 86560 [ 1168.220978] connection3:0: detected conn error (1011) [ 1168.220985] connection6:0: detected conn error (1011) [ 1168.480994] sd 14:0:0:0: [sde] Unhandled error code [ 1168.480998] sd 14:0:0:0: [sde] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1168.481001] sd 14:0:0:0: [sde] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1168.481009] end_request: I/O error, dev sde, sector 0 [ 1168.481015] Buffer I/O error on device sde, logical block 0 [ 1168.481076] sd 11:0:0:0: [sdc] Unhandled error code [ 1168.481078] sd 11:0:0:0: [sdc] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1168.481080] sd 11:0:0:0: [sdc] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1168.481087] end_request: I/O error, dev sdc, sector 0 [ 1168.481092] Buffer I/O error on device sdc, logical block 0 [ 1168.481144] sd 10:0:0:0: [sdd] Unhandled error code [ 1168.481147] sd 10:0:0:0: [sdd] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1168.481150] sd 10:0:0:0: [sdd] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1168.481156] end_request: I/O error, dev sdd, sector 0 [ 1168.481163] Buffer I/O error on device sdd, logical block 0 [ 1168.481168] sd 13:0:0:0: [sdj] Unhandled error code [ 1168.481170] sd 13:0:0:0: [sdj] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1168.481172] sd 13:0:0:0: [sdj] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1168.481178] end_request: I/O error, dev sdj, sector 0 [ 1168.481184] Buffer I/O error on device sdj, logical block 0 [ 1457.105996] device-mapper: multipath round-robin: version 1.0.0 loaded [ 1457.106155] device-mapper: multipath: Cannot access device path 8:0: -16 [ 1457.106164] device-mapper: table: 252:1: multipath: error getting device [ 1457.106172] device-mapper: ioctl: error adding target to table [ 1457.171292] device-mapper: multipath: Cannot access device path 8:0: -16 [ 1457.171299] device-mapper: table: 252:1: multipath: error getting device [ 1457.171304] device-mapper: ioctl: error adding target to table [root@xen3 ~]# fdisk -l Disk /dev/sda: 299.4 GB, 299439751168 bytes 255 heads, 63 sectors/track, 36404 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/sda1 1 5 40131 de Dell Utility /dev/sda2 * 6 528 4194304 83 Linux Partition 2 does not end on cylinder boundary. /dev/sda3 528 1050 4194304 83 Linux /dev/sda4 1050 36404 283986359+ 8e Linux LVM Disk /dev/sdb: 2040 MB, 2040528896 bytes 255 heads, 63 sectors/track, 248 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/sdb1 1 248 1992028+ 83 Linux Disk /dev/dm-1: 2040 MB, 2040528896 bytes 255 heads, 63 sectors/track, 248 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/dm-1p1 1 248 1992028+ 83 Linux [root@xen3 ~]# xe sr-probe type=lvmoiscsi device-config:target=192.168.130.101 device-config:targetIQN=iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 Error code: SR_BACKEND_FAILURE_107 Error parameters: , The SCSIid parameter is missing or incorrect, <?xml version="1.0" ?> <iscsi-target/> Note: the xml ends there correctly on the last line - it doesn't ever return a list of LUNs (and there is one in the group on the SAN for those servers.

    Read the article

  • NFS issue brings down entire vSphere ESX estate

    - by growse
    I experienced an odd issue this morning where an NFS issue appeared to have taken down the majority of my VMs hosted on a small vSphere 5.0 estate. The infrastructure itself is 4x IBM HS21 blades running around 20 VMs. The storage is provided by a single HP X1600 array with attached D2700 chassis running Solaris 11. There's a couple of storage pools on this which are exposed over NFS for the storage of the VM files, and some iSCSI LUNs for things like MSCS shared disks. Normally, this is pretty stable, but I appreciate the lack of resiliancy in having a single X1600 doing all the storage. This morning, in the logs of each ESX host, at around 0521 GMT I saw a lot of entries like this: 2011-11-30T05:21:54.161Z cpu2:2050)NFSLock: 608: Stop accessing fd 0x41000a4cf9a8 3 2011-11-30T05:21:54.161Z cpu2:2050)NFSLock: 608: Stop accessing fd 0x41000a4dc9e8 3 2011-11-30T05:21:54.161Z cpu2:2050)NFSLock: 608: Stop accessing fd 0x41000a4d3fa8 3 2011-11-30T05:21:54.161Z cpu2:2050)NFSLock: 608: Stop accessing fd 0x41000a4de0a8 3 [....] 2011-11-30T06:16:07.042Z cpu0:2058)WARNING: NFS: 283: Lost connection to the server 10.13.111.197 mount point /sastank/VMStorage, mounted as f0342e1c-19be66b5-0000-000000000000 ("SAStank") 2011-11-30T06:17:01.459Z cpu2:4011)NFS: 292: Restored connection to the server 10.13.111.197 mount point /sastank/VMStorage, mounted as f0342e1c-19be66b5-0000-000000000000 ("SAStank") 2011-11-30T06:25:17.887Z cpu3:2051)NFSLock: 608: Stop accessing fd 0x41000a4c2b28 3 2011-11-30T06:27:16.063Z cpu3:4011)NFSLock: 568: Start accessing fd 0x41000a4d8928 again 2011-11-30T06:35:30.827Z cpu1:2058)WARNING: NFS: 283: Lost connection to the server 10.13.111.197 mount point /tank/ISO, mounted as 5acdbb3e-410e56e3-0000-000000000000 ("ISO (1)") 2011-11-30T06:36:37.953Z cpu6:2054)NFS: 292: Restored connection to the server 10.13.111.197 mount point /tank/ISO, mounted as 5acdbb3e-410e56e3-0000-000000000000 ("ISO (1)") 2011-11-30T06:40:08.242Z cpu6:2054)NFSLock: 608: Stop accessing fd 0x41000a4c3e68 3 2011-11-30T06:40:34.647Z cpu3:2051)NFSLock: 568: Start accessing fd 0x41000a4d8928 again 2011-11-30T06:44:42.663Z cpu1:2058)WARNING: NFS: 283: Lost connection to the server 10.13.111.197 mount point /sastank/VMStorage, mounted as f0342e1c-19be66b5-0000-000000000000 ("SAStank") 2011-11-30T06:44:53.973Z cpu0:4011)NFS: 292: Restored connection to the server 10.13.111.197 mount point /sastank/VMStorage, mounted as f0342e1c-19be66b5-0000-000000000000 ("SAStank") 2011-11-30T06:51:28.296Z cpu5:2058)NFSLock: 608: Stop accessing fd 0x41000ae3c528 3 2011-11-30T06:51:44.024Z cpu4:2052)NFSLock: 568: Start accessing fd 0x41000ae3b8e8 again 2011-11-30T06:56:30.758Z cpu4:2058)WARNING: NFS: 283: Lost connection to the server 10.13.111.197 mount point /sastank/VMStorage, mounted as f0342e1c-19be66b5-0000-000000000000 ("SAStank") 2011-11-30T06:56:53.389Z cpu7:2055)NFS: 292: Restored connection to the server 10.13.111.197 mount point /sastank/VMStorage, mounted as f0342e1c-19be66b5-0000-000000000000 ("SAStank") 2011-11-30T07:01:50.350Z cpu6:2054)ScsiDeviceIO: 2316: Cmd(0x41240072bc80) 0x12, CmdSN 0x9803 to dev "naa.600508e000000000505c16815a36c50d" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x24 0x0. 2011-11-30T07:03:48.449Z cpu3:2051)NFSLock: 608: Stop accessing fd 0x41000ae46b68 3 2011-11-30T07:03:57.318Z cpu4:4009)NFSLock: 568: Start accessing fd 0x41000ae48228 again (I've put a complete dump from one of the hosts on pastebin: http://pastebin.com/Vn60wgTt) When I got in the office at 9am, I saw various failures and alarms and troubleshooted the issue. It turned out that pretty much all of the VMs were inaccessible, and that the ESX hosts either were describing each VM as 'powered off', 'powered on', or 'unavailable'. The VMs described as 'powered on' where not in any way reachable or responding to pings, so this may be lies. There's absolutely no indication on the X1600 that anything was awry, and nothing on the switches to indicate any loss of connectivity. I only managed to resolve the issue by rebooting the ESX hosts in turn. I have a number of questions: What the hell happened? If this was a temporary NFS failure, why did it put the ESX hosts into a state from which a reboot was the only recovery? In the future, when the NFS server goes a little off-piste, what would be the best approach to add some resilience? I've been looking at budgeting for next year and potentially have budget to purchase another X1600/D2700/disks, would an identical mirrored disk setup help to mitigate these sorts of failures automatically? Edit (Added requested details) To expand with some details as requested: The X1600 has 12x 1TB disks lumped together in mirrored pairs as tank, and the D2700 (connected with a mini SAS cable) has 12x 300GB 10k SAS disks lumped together in mirrored pairs as sastank zpool status pool: rpool state: ONLINE scan: none requested config: NAME STATE READ WRITE CKSUM rpool ONLINE 0 0 0 c7t0d0s0 ONLINE 0 0 0 errors: No known data errors pool: sastank state: ONLINE scan: scrub repaired 0 in 74h21m with 0 errors on Wed Nov 30 02:51:58 2011 config: NAME STATE READ WRITE CKSUM sastank ONLINE 0 0 0 mirror-0 ONLINE 0 0 0 c7t14d0 ONLINE 0 0 0 c7t15d0 ONLINE 0 0 0 mirror-1 ONLINE 0 0 0 c7t16d0 ONLINE 0 0 0 c7t17d0 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 c7t18d0 ONLINE 0 0 0 c7t19d0 ONLINE 0 0 0 mirror-3 ONLINE 0 0 0 c7t20d0 ONLINE 0 0 0 c7t21d0 ONLINE 0 0 0 mirror-4 ONLINE 0 0 0 c7t22d0 ONLINE 0 0 0 c7t23d0 ONLINE 0 0 0 mirror-5 ONLINE 0 0 0 c7t24d0 ONLINE 0 0 0 c7t25d0 ONLINE 0 0 0 errors: No known data errors pool: tank state: ONLINE scan: scrub repaired 0 in 17h28m with 0 errors on Mon Nov 28 17:58:19 2011 config: NAME STATE READ WRITE CKSUM tank ONLINE 0 0 0 mirror-0 ONLINE 0 0 0 c7t1d0 ONLINE 0 0 0 c7t2d0 ONLINE 0 0 0 mirror-1 ONLINE 0 0 0 c7t3d0 ONLINE 0 0 0 c7t4d0 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 c7t5d0 ONLINE 0 0 0 c7t6d0 ONLINE 0 0 0 mirror-3 ONLINE 0 0 0 c7t8d0 ONLINE 0 0 0 c7t9d0 ONLINE 0 0 0 mirror-4 ONLINE 0 0 0 c7t10d0 ONLINE 0 0 0 c7t11d0 ONLINE 0 0 0 mirror-5 ONLINE 0 0 0 c7t12d0 ONLINE 0 0 0 c7t13d0 ONLINE 0 0 0 errors: No known data errors The filesystem exposed over NFS for the primary datastore is sastank/VMStorage zfs list NAME USED AVAIL REFER MOUNTPOINT rpool 45.1G 13.4G 92.5K /rpool rpool/ROOT 2.28G 13.4G 31K legacy rpool/ROOT/solaris 2.28G 13.4G 2.19G / rpool/dump 15.0G 13.4G 15.0G - rpool/export 11.9G 13.4G 32K /export rpool/export/home 11.9G 13.4G 32K /export/home rpool/export/home/andrew 11.9G 13.4G 11.9G /export/home/andrew rpool/swap 15.9G 29.2G 123M - sastank 1.08T 536G 33K /sastank sastank/VMStorage 1.01T 536G 1.01T /sastank/VMStorage sastank/comstar 71.7G 536G 31K /sastank/comstar sastank/comstar/sql_tempdb 6.31G 536G 6.31G - sastank/comstar/sql_tx_data 65.4G 536G 65.4G - tank 4.79T 578G 42K /tank tank/FTP 269G 578G 269G /tank/FTP tank/ISO 28.8G 578G 25.9G /tank/ISO tank/backupstage 2.64T 578G 2.49T /tank/backupstage tank/cifs 301G 578G 297G /tank/cifs tank/comstar 1.54T 578G 31K /tank/comstar tank/comstar/msdtc 1.07G 579G 32.8M - tank/comstar/quorum 577M 578G 47.9M - tank/comstar/sqldata 1.54T 886G 304G - tank/comstar/vsphere_lun 2.09G 580G 22.2M - tank/mcs-asset-repository 7.01M 578G 6.99M /tank/mcs-asset-repository tank/mscs-quorum 55K 578G 36K /tank/mscs-quorum tank/sccm 16.1G 578G 12.8G /tank/sccm As for the networking, all connections between the X1600, the Blades and the switch are either LACP or Etherchannel bonded 2x 1Gbit links. Switch is a single Cisco 3750. Storage traffic sits on its own VLAN segregated from VM machine traffic.

    Read the article

  • ESX3.5 Cluster & MD3000i -- Both servers see iSCSI Targets, Only one server can use partition.

    - by GruffTech
    Alright. First and foremost, Warning. This is a bigger-then-normal question. I like to be thorough and try to eliminate all possible "easymode" answers, as well as give everyone a feel of what i've tried. I've included several images of our setup and the problem it is having.. TLDR Version: So I've followed the guides located here: ESX Deployment Guide V1 this is the guide Dell has sent me to setup two ESX3.5 servers mounting a Dell MD3000i. It doesn't work. Both servers can't use the same storage partition on the MD3000. Both servers see it, but only one server can actually use it. (that server being whatever server created the partition on the target.) Both ESX servers are members of the Host Group. Full Version I have 2 ESX3.5 Servers (10.0.7.102, also called EPI2, and 10.0.7.103, also called EPI3.) connected to a iSCSI SAN Device (Dell MD3000i). Both ESX servers can "scan" the SAN and see the LUNS. Part One: MD3000i Storage On the MD3000i, Both servers are in my host group. I have two partitions, VM1 and VM2, both 1.6TB (vmware doesn't like anything past 2tb.) And you can even see that the ESX servers are targetting the MD3000 just fine. Part Two: The ESX Servers Figure 1. So as you can see above, Both ESX Servers (10.0.7.102 and 10.0.7.103) are able to see and scan the MD3000i SAN. Figure 2. Above is the storage both servers see. I created the storage partition on EPI2 (102). I then Extended the partition to include the second LUN for a grand total of 3.27 TB of storage. When i "rescan" on 103 (the server not mounting the partition), I get the below log in log/messages. Mar 11 10:41:18 epi3 kernel: scsi1: remove-single-device 0 0 0 failed, device busy(4). being the only line that grabs my attentions. (EPI3 is the server name) Mar 11 10:41:04 epi3 vmkiscsid[5436]: Connected to Discovery Address 192.168.130.101 Mar 11 10:41:04 epi3 vmkiscsid[5437]: Connected to Discovery Address 192.168.130.102 Mar 11 10:41:04 epi3 vmkiscsid[5438]: Connected to Discovery Address 192.168.131.101 Mar 11 10:41:04 epi3 vmkiscsid[5439]: Connected to Discovery Address 192.168.131.102 Mar 11 10:41:17 epi3 kernel: scsi singledevice 2 0 0 0 Mar 11 10:41:17 epi3 kernel: Vendor: DELL Model: MD3000i Rev: 0735 Mar 11 10:41:17 epi3 kernel: Type: Direct-Access ANSI SCSI revision: 05 Mar 11 10:41:17 epi3 kernel: VMWARE SCSI Id: Supported VPD pages for sdb : 0x0 0x80 0x83 0x85 0x86 0x87 0xc0 0xc1 0xc2 0xc3 0xc4 0xc8 0xc9 0xca 0xd0 Mar 11 10:41:17 epi3 kernel: VMWARE SCSI Id: Device id info for sdb: 0x1 0x3 0x0 0x10 0x60 0x1 0xe4 0xf0 0x0 0x1a 0x1a 0xa2 0x0 0x0 0x15 0xe2 0x4d 0x75 0xf6 0x99 0x53 0x98 0x0 0x54 0x69 0x71 0x6e 0x2e 0x31 0x39 0x38 0x34 0x2d 0x30 0x35 0x2e 0x63 0x6f 0x6d 0x2e 0x64 0x65 0x6c 0x6c 0x3a 0x70 0x6f 0x77 0x65 0x72 0x76 0x61 0x75 0x6c 0x74 0x2e 0x36 0x30 0x30 0x31 0x65 0x34 0x66 0x30 0x30 0x30 0x31 0x61 0x31 0x61 0x61 0x32 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x34 0x37 0x39 0x30 0x36 0x32 0x32 0x65 0x2c 0x74 0x2c 0x30 0x78 0x30 0x30 0x30 0x31 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x32 0x0 0x0 0x0 0x51 0x94 0x0 0x4 0x0 0x0 0x80 0x1 0x53 0xa8 0x0 0x44 0x69 0x71 0x6e 0x2e 0x31 0x39 0x38 0x34 0x2d 0x30 0x35 0x2e 0x63 0x6f 0x6d 0x2e 0x64 0x65 0x6c 0x6c 0x3a 0x70 0x6f 0x77 0x65 0x72 0x76 0x61 0x75 0x6c 0x74 0x2e 0x36 0x30 0x30 0x31 0x65 0x34 0x66 0x30 0x30 0x30 0x31 0x61 0x31 0x61 0x61 0x32 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x34 0x37 0x39 0x30 0x36 0x32 0x32 0x65 0x0 0x0 0x0 0x0 Mar 11 10:41:17 epi3 kernel: VMWARE SCSI Id: Id for sdb 0x60 0x01 0xe4 0xf0 0x00 0x1a 0x1a 0xa2 0x00 0x00 0x15 0xe2 0x4d 0x75 0xf6 0x99 0x4d 0x44 0x33 0x30 0x30 0x30 Mar 11 10:41:17 epi3 kernel: VMWARE: Unique Device attached as scsi disk sdb at scsi2, channel 0, id 0, lun 0 Mar 11 10:41:17 epi3 kernel: Attached scsi disk sdb at scsi2, channel 0, id 0, lun 0 Mar 11 10:41:17 epi3 kernel: scan_scsis starting finish Mar 11 10:41:17 epi3 kernel: SCSI device sdb: 3509329920 512-byte hdwr sectors (1797751 MB) Mar 11 10:41:17 epi3 kernel: sdb: sdb1 Mar 11 10:41:17 epi3 kernel: scan_scsis done with finish Mar 11 10:41:17 epi3 kernel: scsi singledevice 2 0 0 1 Mar 11 10:41:17 epi3 kernel: Vendor: DELL Model: MD3000i Rev: 0735 Mar 11 10:41:17 epi3 kernel: Type: Direct-Access ANSI SCSI revision: 05 Mar 11 10:41:18 epi3 kernel: VMWARE SCSI Id: Supported VPD pages for sdc : 0x0 0x80 0x83 0x85 0x86 0x87 0xc0 0xc1 0xc2 0xc3 0xc4 0xc8 0xc9 0xca 0xd0 Mar 11 10:41:18 epi3 kernel: VMWARE SCSI Id: Device id info for sdc: 0x1 0x3 0x0 0x10 0x60 0x1 0xe4 0xf0 0x0 0x1a 0x1a 0x86 0x0 0x0 0xd 0xb7 0x4d 0x75 0xf2 0x77 0x53 0x98 0x0 0x54 0x69 0x71 0x6e 0x2e 0x31 0x39 0x38 0x34 0x2d 0x30 0x35 0x2e 0x63 0x6f 0x6d 0x2e 0x64 0x65 0x6c 0x6c 0x3a 0x70 0x6f 0x77 0x65 0x72 0x76 0x61 0x75 0x6c 0x74 0x2e 0x36 0x30 0x30 0x31 0x65 0x34 0x66 0x30 0x30 0x30 0x31 0x61 0x31 0x61 0x61 0x32 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x34 0x37 0x39 0x30 0x36 0x32 0x32 0x65 0x2c 0x74 0x2c 0x30 0x78 0x30 0x30 0x30 0x31 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x32 0x0 0x0 0x0 0x51 0x94 0x0 0x4 0x0 0x0 0x80 0x1 0x53 0xa8 0x0 0x44 0x69 0x71 0x6e 0x2e 0x31 0x39 0x38 0x34 0x2d 0x30 0x35 0x2e 0x63 0x6f 0x6d 0x2e 0x64 0x65 0x6c 0x6c 0x3a 0x70 0x6f 0x77 0x65 0x72 0x76 0x61 0x75 0x6c 0x74 0x2e 0x36 0x30 0x30 0x31 0x65 0x34 0x66 0x30 0x30 0x30 0x31 0x61 0x31 0x61 0x61 0x32 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x34 0x37 0x39 0x30 0x36 0x32 0x32 0x65 0x0 0x0 0x0 0x0 Mar 11 10:41:18 epi3 kernel: VMWARE SCSI Id: Id for sdc 0x60 0x01 0xe4 0xf0 0x00 0x1a 0x1a 0x86 0x00 0x00 0x0d 0xb7 0x4d 0x75 0xf2 0x77 0x4d 0x44 0x33 0x30 0x30 0x30 Mar 11 10:41:18 epi3 kernel: VMWARE: Unique Device attached as scsi disk sdc at scsi2, channel 0, id 0, lun 1 Mar 11 10:41:18 epi3 kernel: Attached scsi disk sdc at scsi2, channel 0, id 0, lun 1 Mar 11 10:41:18 epi3 kernel: scan_scsis starting finish Mar 11 10:41:18 epi3 kernel: SCSI device sdc: 3509329920 512-byte hdwr sectors (1797751 MB) Mar 11 10:41:18 epi3 kernel: sdc: sdc1 Mar 11 10:41:18 epi3 kernel: scan_scsis done with finish Mar 11 10:41:18 epi3 kernel: scsi1: remove-single-device 0 0 0 failed, device busy(4). Mar 11 10:41:18 epi3 kernel: scsi singledevice 1 0 0 0 Things I've Tried: Removing iSCSI targets from only 103, disabling iSCSI, rebooting, enabled iSCSI, re-adding targets, rescan. Same result. Removing partition on 102, Formatted partition on 103 instead. Same result, except flipped. 103 can use storage, 102 can not. Starting Over. Removing all iSCSI Targets on both ESX Boxes, disabling iSCSI, turning off the firewall for iSCSI, rebooting ESX. Then on the MD3000, Removed the Host Group, Removed the Host-to-Virtual Mappings, Restarted the SAN. Followed the Documentation again, same result. Both servers see the storage, but only one server can use it. Disabling and Re-enabling VMware DRS and HA. Same result. Flat-out turning off VMware DRS and HA, and doing the "start over" step to see if maybe that borked it. Same Result. I'm kinda loosing my mind here, Everything i read online says "just partition it and if the ESX boxes can see the targets, it just works".... well crap. Any ideas, any other things to try? Can anyone atleast point me in the right direction? I'm really tired of working from 1am til 4am (our maintenance hours)

    Read the article

  • Oracle Solaris: Zones on Shared Storage

    - by Jeff Victor
    Oracle Solaris 11.1 has several new features. At oracle.com you can find a detailed list. One of the significant new features, and the most significant new feature releated to Oracle Solaris Zones, is casually called "Zones on Shared Storage" or simply ZOSS (rhymes with "moss"). ZOSS offers much more flexibility because you can store Solaris Zones on shared storage (surprise!) so that you can perform quick and easy migration of a zone from one system to another. This blog entry describes and demonstrates the use of ZOSS. ZOSS provides complete support for a Solaris Zone that is stored on "shared storage." In this case, "shared storage" refers to fiber channel (FC) or iSCSI devices, although there is one lone exception that I will demonstrate soon. The primary intent is to enable you to store a zone on FC or iSCSI storage so that it can be migrated from one host computer to another much more easily and safely than in the past. With this blog entry, I wanted to make it easy for you to try this yourself. I couldn't assume that you have a SAN available - which is a good thing, because neither do I! What could I use, instead? [There he goes, foreshadowing again... -Ed.] Developing this entry reinforced the lesson that the solution to every lab problem is VirtualBox. Oracle VM VirtualBox (its formal name) helps here in a couple of important ways. It offers the ability to easily install multiple copies of Solaris as guests on top of any popular system (Microsoft Windows, MacOS, Solaris, Oracle Linux (and other Linuxes) etc.). It also offers the ability to create a separate virtual disk drive (VDI) that appears as a local hard disk to a guest. This virtual disk can be moved very easily from one guest to another. In other words, you can follow the steps below on a laptop or larger x86 system. Please note that the ability to use ZOSS to store a zone on a local disk is very useful for a lab environment, but not so useful for production. I do not suggest regularly moving disk drives among computers. In the method I describe below, that virtual hard disk will contain the zone that will be migrated among the (virtual) hosts. In production, you would use FC or iSCSI LUNs instead. The zonecfg(1M) man page details the syntax for each of the three types of devices. Why Migrate? Why is the migration of virtual servers important? Some of the most common reasons are: Moving a workload to a different computer so that the original computer can be turned off for extensive maintenance. Moving a workload to a larger system because the workload has outgrown its original system. If the workload runs in an environment (such as a Solaris Zone) that is stored on shared storage, you can restore the service of the workload on an alternate computer if the original computer has failed and will not reboot. You can simplify lifecycle management of a workload by developing it on a laptop, migrating it to a test platform when it's ready, and finally moving it to a production system. Concepts For ZOSS, the important new concept is named "rootzpool". You can read about it in the zonecfg(1M) man page, but here's the short version: it's the backing store (hard disk(s), or LUN(s)) that will be used to make a ZFS zpool - the zpool that will hold the zone. This zpool: contains the zone's Solaris content, i.e. the root file system does not contain any content not related to the zone can only be mounted by one Solaris instance at a time Method Overview Here is a brief list of the steps to create a zone on shared storage and migrate it. The next section shows the commands and output. You will need a host system with an x86 CPU (hopefully at least a couple of CPU cores), at least 2GB of RAM, and at least 25GB of free disk space. (The steps below will not actually use 25GB of disk space, but I don't want to lead you down a path that ends in a big sign that says "Your HDD is full. Good luck!") Configure the zone on both systems, specifying the rootzpool that both will use. The best way is to configure it on one system and then copy the output of "zonecfg export" to the other system to be used as input to zonecfg. This method reduces the chances of pilot error. (It is not necessary to configure the zone on both systems before creating it. You can configure this zone in multiple places, whenever you want, and migrate it to one of those places at any time - as long as those systems all have access to the shared storage.) Install the zone on one system, onto shared storage. Boot the zone. Provide system configuration information to the zone. (In the Real World(tm) you will usually automate this step.) Shutdown the zone. Detach the zone from the original system. Attach the zone to its new "home" system. Boot the zone. The zone can be used normally, and even migrated back, or to a different system. Details The rest of this shows the commands and output. The two hostnames are "sysA" and "sysB". Note that each Solaris guest might use a different device name for the VDI that they share. I used the device names shown below, but you must discover the device name(s) after booting each guest. In a production environment you would also discover the device name first and then configure the zone with that name. Fortunately, you can use the command "zpool import" or "format" to discover the device on the "new" host for the zone. The first steps create the VirtualBox guests and the shared disk drive. I describe the steps here without demonstrating them. Download VirtualBox and install it using a method normal for your host OS. You can read the complete instructions. Create two VirtualBox guests, each to run Solaris 11.1. Each will use its own VDI as its root disk. Install Solaris 11.1 in each guest.Install Solaris 11.1 in each guest. To install a Solaris 11.1 guest, you can either download a pre-built VirtualBox guest, and import it, or install Solaris 11.1 from the "text install" media. If you use the latter method, after booting you will not see a windowing system. To install the GUI and other important things, login and run "pkg install solaris-desktop" and take a break while it installs those important things. Life is usually easier if you install the VirtualBox Guest Additions because then you can copy and paste between the host and guests, etc. You can find the guest additions in the folder matching the version of VirtualBox you are using. You can also read the instructions for installing the guest additions. To create the zone's shared VDI in VirtualBox, you can open the storage configuration for one of the two guests, select the SATA controller, and click on the "Add Hard Disk" icon nearby. Choose "Create New Disk" and specify an appropriate path name for the file that will contain the VDI. The shared VDI must be at least 1.5 GB. Note that the guest must be stopped to do this. Add that VDI to the other guest - using its Storage configuration - so that each can access it while running. The steps start out the same, except that you choose "Choose Existing Disk" instead of "Create New Disk." Because the disk is configured on both of them, VirtualBox prevents you from running both guests at the same time. Identify device names of that VDI, in each of the guests. Solaris chooses the name based on existing devices. The names may be the same, or may be different from each other. This step is shown below as "Step 1." Assumptions In the example shown below, I make these assumptions. The guest that will own the zone at the beginning is named sysA. The guest that will own the zone after the first migration is named sysB. On sysA, the shared disk is named /dev/dsk/c7t2d0 On sysB, the shared disk is named /dev/dsk/c7t3d0 (Finally!) The Steps Step 1) Determine the name of the disk that will move back and forth between the systems. root@sysA:~# format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c7t0d0 /pci@0,0/pci8086,2829@d/disk@0,0 1. c7t2d0 /pci@0,0/pci8086,2829@d/disk@2,0 Specify disk (enter its number): ^D Step 2) The first thing to do is partition and label the disk. The magic needed to write an EFI label is not overly complicated. root@sysA:~# format -e c7t2d0 selecting c7t2d0 [disk formatted] FORMAT MENU: ... format fdisk No fdisk table exists. The default partition for the disk is: a 100% "SOLARIS System" partition Type "y" to accept the default partition, otherwise type "n" to edit the partition table. n SELECT ONE OF THE FOLLOWING: ... Enter Selection: 1 ... G=EFI_SYS 0=Exit? f SELECT ONE... ... 6 format label ... Specify Label type[1]: 1 Ready to label disk, continue? y format quit root@sysA:~# ls /dev/dsk/c7t2d0 /dev/dsk/c7t2d0 Step 3) Configure zone1 on sysA. root@sysA:~# zonecfg -z zone1 Use 'create' to begin configuring a new zone. zonecfg:zone1 create create: Using system default template 'SYSdefault' zonecfg:zone1 set zonename=zone1 zonecfg:zone1 set zonepath=/zones/zone1 zonecfg:zone1 add rootzpool zonecfg:zone1:rootzpool add storage dev:dsk/c7t2d0 zonecfg:zone1:rootzpool end zonecfg:zone1 exit root@sysA:~# oot@sysA:~# zonecfg -z zone1 info zonename: zone1 zonepath: /zones/zone1 brand: solaris autoboot: false bootargs: file-mac-profile: pool: limitpriv: scheduling-class: ip-type: exclusive hostid: fs-allowed: anet: ... rootzpool: storage: dev:dsk/c7t2d0 Step 4) Install the zone. This step takes the most time, but you can wander off for a snack or a few laps around the gym - or both! (Just not at the same time...) root@sysA:~# zoneadm -z zone1 install Created zone zpool: zone1_rpool Progress being logged to /var/log/zones/zoneadm.20121022T163634Z.zone1.install Image: Preparing at /zones/zone1/root. AI Manifest: /tmp/manifest.xml.RXaycg SC Profile: /usr/share/auto_install/sc_profiles/enable_sci.xml Zonename: zone1 Installation: Starting ... Creating IPS image Startup linked: 1/1 done Installing packages from: solaris origin: http://pkg.us.oracle.com/support/ DOWNLOAD PKGS FILES XFER (MB) SPEED Completed 183/183 33556/33556 222.2/222.2 2.8M/s PHASE ITEMS Installing new actions 46825/46825 Updating package state database Done Updating image state Done Creating fast lookup database Done Installation: Succeeded Note: Man pages can be obtained by installing pkg:/system/manual done. Done: Installation completed in 1696.847 seconds. Next Steps: Boot the zone, then log into the zone console (zlogin -C) to complete the configuration process. Log saved in non-global zone as /zones/zone1/root/var/log/zones/zoneadm.20121022T163634Z.zone1.install Step 5) Boot the Zone. root@sysA:~# zoneadm -z zone1 boot Step 6) Login to zone's console to complete the specification of system information. root@sysA:~# zlogin -C zone1 Answer the usual questions and wait for a login prompt. Then you can end the console session with the usual "~." incantation. Step 7) Shutdown the zone so it can be "moved." root@sysA:~# zoneadm -z zone1 shutdown Step 8) Detach the zone so that the original global zone can't use it. root@sysA:~# zoneadm list -cv ID NAME STATUS PATH BRAND IP 0 global running / solaris shared - zone1 installed /zones/zone1 solaris excl root@sysA:~# zpool list NAME SIZE ALLOC FREE CAP DEDUP HEALTH ALTROOT rpool 17.6G 11.2G 6.47G 63% 1.00x ONLINE - zone1_rpool 1.98G 484M 1.51G 23% 1.00x ONLINE - root@sysA:~# zoneadm -z zone1 detach Exported zone zpool: zone1_rpool Step 9) Review the result and shutdown sysA so that sysB can use the shared disk. root@sysA:~# zpool list NAME SIZE ALLOC FREE CAP DEDUP HEALTH ALTROOT rpool 17.6G 11.2G 6.47G 63% 1.00x ONLINE - root@sysA:~# zoneadm list -cv ID NAME STATUS PATH BRAND IP 0 global running / solaris shared - zone1 configured /zones/zone1 solaris excl root@sysA:~# init 0 Step 10) Now boot sysB and configure a zone with the parameters shown above in Step 1. (Again, the safest method is to use "zonecfg ... export" on sysA as described in section "Method Overview" above.) The one difference is the name of the rootzpool storage device, which was shown in the list of assumptions, and which you must determine by booting sysB and using the "format" or "zpool import" command. When that is done, you should see the output shown next. (I used the same zonename - "zone1" - in this example, but you can choose any valid zonename you want.) root@sysB:~# zoneadm list -cv ID NAME STATUS PATH BRAND IP 0 global running / solaris shared - zone1 configured /zones/zone1 solaris excl root@sysB:~# zonecfg -z zone1 info zonename: zone1 zonepath: /zones/zone1 brand: solaris autoboot: false bootargs: file-mac-profile: pool: limitpriv: scheduling-class: ip-type: exclusive hostid: fs-allowed: anet: linkname: net0 ... rootzpool: storage: dev:dsk/c7t3d0 Step 11) Attaching the zone automatically imports the zpool. root@sysB:~# zoneadm -z zone1 attach Imported zone zpool: zone1_rpool Progress being logged to /var/log/zones/zoneadm.20121022T184034Z.zone1.attach Installing: Using existing zone boot environment Zone BE root dataset: zone1_rpool/rpool/ROOT/solaris Cache: Using /var/pkg/publisher. Updating non-global zone: Linking to image /. Processing linked: 1/1 done Updating non-global zone: Auditing packages. No updates necessary for this image. Updating non-global zone: Zone updated. Result: Attach Succeeded. Log saved in non-global zone as /zones/zone1/root/var/log/zones/zoneadm.20121022T184034Z.zone1.attach root@sysB:~# zoneadm -z zone1 boot root@sysB:~# zlogin zone1 [Connected to zone 'zone1' pts/2] Oracle Corporation SunOS 5.11 11.1 September 2012 Step 12) Now let's migrate the zone back to sysA. Create a file in zone1 so we can verify it exists after we migrate the zone back, then begin migrating it back. root@zone1:~# ls /opt root@zone1:~# touch /opt/fileA root@zone1:~# ls -l /opt/fileA -rw-r--r-- 1 root root 0 Oct 22 14:47 /opt/fileA root@zone1:~# exit logout [Connection to zone 'zone1' pts/2 closed] root@sysB:~# zoneadm -z zone1 shutdown root@sysB:~# zoneadm -z zone1 detach Exported zone zpool: zone1_rpool root@sysB:~# init 0 Step 13) Back on sysA, check the status. Oracle Corporation SunOS 5.11 11.1 September 2012 root@sysA:~# zoneadm list -cv ID NAME STATUS PATH BRAND IP 0 global running / solaris shared - zone1 configured /zones/zone1 solaris excl root@sysA:~# zpool list NAME SIZE ALLOC FREE CAP DEDUP HEALTH ALTROOT rpool 17.6G 11.2G 6.47G 63% 1.00x ONLINE - Step 14) Re-attach the zone back to sysA. root@sysA:~# zoneadm -z zone1 attach Imported zone zpool: zone1_rpool Progress being logged to /var/log/zones/zoneadm.20121022T190441Z.zone1.attach Installing: Using existing zone boot environment Zone BE root dataset: zone1_rpool/rpool/ROOT/solaris Cache: Using /var/pkg/publisher. Updating non-global zone: Linking to image /. Processing linked: 1/1 done Updating non-global zone: Auditing packages. No updates necessary for this image. Updating non-global zone: Zone updated. Result: Attach Succeeded. Log saved in non-global zone as /zones/zone1/root/var/log/zones/zoneadm.20121022T190441Z.zone1.attach root@sysA:~# zpool list NAME SIZE ALLOC FREE CAP DEDUP HEALTH ALTROOT rpool 17.6G 11.2G 6.47G 63% 1.00x ONLINE - zone1_rpool 1.98G 491M 1.51G 24% 1.00x ONLINE - root@sysA:~# zoneadm -z zone1 boot root@sysA:~# zlogin zone1 [Connected to zone 'zone1' pts/2] Oracle Corporation SunOS 5.11 11.1 September 2012 root@zone1:~# zpool list NAME SIZE ALLOC FREE CAP DEDUP HEALTH ALTROOT rpool 1.98G 538M 1.46G 26% 1.00x ONLINE - Step 15) Check for the file created on sysB, earlier. root@zone1:~# ls -l /opt total 1 -rw-r--r-- 1 root root 0 Oct 22 14:47 fileA Next Steps Here is a brief list of some of the fun things you can try next. Add space to the zone by adding a second storage device to the rootzpool. Make sure that you add it to the configurations of both zones! Create a new zone, specifying two disks in the rootzpool when you first configure the zone. When you install that zone, or clone it from another zone, zoneadm uses those two disks to create a mirrored pool. (Three disks will result in a three-way mirror, etc.) Conclusion Hopefully you have seen the ease with which you can now move Solaris Zones from one system to another.

    Read the article