Search Results

Search found 71 results on 3 pages for 'luns'.

Page 1/3 | 1 2 3  | Next Page >

  • Expanding iSCSI LUNs (NTFS)

    - by Fatih
    I have a 4TB iSCSI LUN that formated as NTFS in Windows 2008. I've shared this formated volume as a folder over SMB. When the capacity of this volume is not enough, I have to add more iSCSI LUNs, but the end-users must see only the folder that I've shared before. So, when I expand the NTFS volume that is currently 4TB, with more iSCSI LUNS(for example 2 more 4TB LUN), if one of the luns is failed, or missing, will all of my data in the folder be lost? I imagine that the expanding ntfs volume is like RAID 0(striped). if it is like RAID 0, then all my data will be lost when one of the luns is failed, or missing. In brief, there are two questions in here: 1- What will be happened, if one of the luns is missing in an expanded ntfs volume? 2- Is there another way to merge all of iscsi luns as only a folder, in that way the users don't see any extra folder even if I add extra iscsi luns to the file server.(I don't mention about DFS) Regards.

    Read the article

  • LUNs disappear after rebooting the ESX/ESXi host

    - by mariolos
    A single LUN among from a group disappeared. Neither the host nor the Vcenter can see it. Four virtual machines on the LUN now are unknown. The strange thing is the LUN is now available in the list when you try to ADD datastore from configuration == storage == Add Datastore But this cannot help me since i need the vms on the lun and i do not get options to add the lun without formating it to VMFS How can i get the lun back or atleast be able to copy the vms from it

    Read the article

  • Luns not taken by the windows server admin

    - by wildchild
    I have a scenario based question...Something , I haven't faced till now ,but i would be interested to know the answer. If i have assigned a luns (say, of 50 GB) and put them in storage group.However, the windows server team did not grab that lun but sent an acknowledgment saying the Luns are alingned. I would like to know what will happen to the Luns that belong to the SG ..in my opinion they will remain in the SG as unassigned Luns ..or is there a possibility that the lUns will move back to the storage.

    Read the article

  • What is better to have more LUNs or more Storages

    - by skomak
    Hi, what is better to have - more LUNs or more Storages. Actually i have 1 storage ESXi per 1 LUN so there are about 15 LUNs and 15 storages. Now there is a kind of problem because the LUNs have different space allocated so if i remove 2 LUNs f.e. 1 2 3 4 [x] 6 [x] 8 9 (like that) i can't make 1 LUN from 5 and 7 pieces of free diskspace on IBM storage array. It's a first argument to not have a lot of LUNs. If i had to make only a few LUNs (about 3) and inside some Storage from ESXi would it be a better idea? For example for expanding storage capacity? i look for good solutions. Thanks in advance.

    Read the article

  • Xen guests accessing LUNs

    - by mechcow
    We are using RHEL5.3 with a Clarion SAN attached by FC. Our situation is that we have a number of LUNs presented to Hosts and we want to dynamically present the LUNs to Xen Guests. We are not sure on what the best practice approach is to set this up. The Xen guests will form a cluster together and need the LUNs only for data partitions, i.e. when they are actively running services. So one approach would be to always present all disks to all Xen guests, and then rely up on the cluster software, and mount itself, to not mount the disk twice in two locations. This sounds kinda risky and also is not very secure (one cracked guest can see/destroy all the data). Another approach would be to dynamically add and remove the disks from the Xen guests at the dom0 level (using xm block-attach). This could work but sounds slightly complicated, I'm wondering whether Red Hat Cluster Suite supports this in some way or whether there are scripts to do this. Yet another approach would be to have the LUNs endpointed at the Xen guests themselves - I'm not sure whether this is technically possible since the multipathing has to be done at the Host level.

    Read the article

  • iSCSI: LUNs per target?

    - by badnews
    My question relates specifically to ZFS/COMSTAR but I assume is generally applicable to any iSCSI system: Should one prefer to create a target for every LUN that you want to expose? Or is it good practise to have a single target with multiple LUNs? Does either approach have a performance impact? And is there some crossover point where the other approach makes sense? The use case is for VM disks, where each disk (zvol) is a LUN. So far we have created a a separate target for each VM; but a single target that contains all the LUNs would probably greatly simplify management... but we may need hundreds of LUNs per a single target. (And then possibly tens of initiator connections to that target)

    Read the article

  • Problems connecting Clariion LUNS to Solaris 10

    - by vialde
    I've got a Clariion San and a Solaris 10 server with an emulex HBA. The Thin LUNS are visible in Solaris and I can happily format the raw devices. Unfortunately that's all I can do. All other operations result in I/O errors. I'm running current versions of PowerPath and Solaris is patched as high as it'll go. Anyone have any similar experiences?

    Read the article

  • Virtual system drive is split between separate LUNs

    - by Tigran
    My hardware VMWare guy told me that a Win2008R2 server I have has a D drive that is split between two separate LUNs. He could not tell me if that's a good thing or bad just that it's not standard practice for him. Would you please explain the benefits or drawbacks of this setup? Thanks EDIT Some additional info. What happened was I had D drive already allocated. Then I asked for more. They said there's no more space on whatever LUN my D drive is on so the option they gave me was that part of the D drive will be on one LUN and other part will be on another LUN. Hope that helps

    Read the article

  • Virtual system drive is split between separate LUNs

    - by Tigran
    My hardware VMWare guy told me that a Win2008R2 server I have has a D drive that is split between two separate LUNs. He could not tell me if that's a good thing or bad just that it's not standard practice for him. Would you please explain the benefits or drawbacks of this setup? Thanks EDIT Some additional info. What happened was I had D drive already allocated. Then I asked for more. They said there's no more space on whatever LUN my D drive is on so the option they gave me was that part of the D drive will be on one LUN and other part will be on another LUN. Hope that helps

    Read the article

  • ESX hosts lose connectivity with iSCSI SAN LUNs

    - by Themist
    I've been experiencing this issue for a couple of months now where my ESX hosts lose connectivity with my iSCSI SAN vmfs volumes. As a results the ESX hosts enter a nonresponsive mode the associated VMs disconnect and the only remedy is to reboot the host. This issue happens randomly . I have escalated this issue with VMWare but I haven't had any solution to the issue yet. I see no errors on my switches and there are no hardware issues as well. My SAN infrastucture is solid and there are 2 paths for every vmfs volume. Did anybody else experienced a similar issue? Themis

    Read the article

  • ESX hosts lose connectivity with iSCSI SAN LUNs

    - by Themist
    I've been experiencing this issue for a couple of months now where my ESX hosts lose connectivity with my iSCSI SAN vmfs volumes. As a results the ESX hosts enter a nonresponsive mode the associated VMs disconnect and the only remedy is to reboot the host. This issue happens randomly . I have escalated this issue with VMWare but I haven't had any solution to the issue yet. I see no errors on my switches and there are no hardware issues as well. My SAN infrastucture is solid and there are 2 paths for every vmfs volume. Did anybody else experienced a similar issue? edit: Here are some more details: The iSCSI SAN software is Datacore Sanmelody 2.0.4.2 running on 2 HP Proliant G5 servers. The storage attached to each of the servers is an HP MSA70 and all the iSCSI SAN Volumes that are presented to my 4 ESX hosts are mirrored. I have two iSCSI swithces HP Procurve 1800G-24 that are trunked together. My SANLELODY servers are using NC360T NICs. I team two NICs and have one cable connecting to each iSCSi switch. Each ESX server uses two NICs as well for the iSCSI Network.

    Read the article

  • LUNS access issue in ESX4 Cluster server

    - by rmustafa
    HI, I've created volumes in equallogic in PS 6000 XV(having 2 member which is in 1 pool), checked & those volumes can be easily detected my ISCSI software in windows. But the problem with ESX , not able to see the assigned disk on ESX server, I can explain what I've done: 1.Created Cluster with enabled HA & DRS 2.Added 3 ESX4 HOST 3.Added VMkernel & configured in all 3 ESX4, enabled vmotion & FT on the same adapter. 4.went to iSCSI storage adapter properties, enabled iSCSI 5.Trying to discover the available storage with the controller IP on dynamic discovery, but not able to see the assigned storage Note: the same volume is accessed to windows that means there is no issue from storage , am I right ???? Note: I wanted to mount the same volume in all 3 ESX host. Please suggest .... Thanks & Regards, Rashid Mustafa

    Read the article

  • Can I have different ESX hosts accessing the same LUN over different protocols?

    - by Kevin Kuphal
    I currently have a cluster of two ESX 3.5U2 servers connected directly via FiberChannel to a NetApp 3020 cluster. These hosts mount four VMFS LUNs for virtual machine storage. Currently these LUNs are only made available via our FiberChannel initator in the Netapp configuration If I were to add an ESXi host to the cluster for internal IT use can I: Make the same VMFS LUNs available via the iSCSI initiator on the Netapp Connect this ESXi host to those LUNs via iSCSI Do all of this while the existing two ESX hosts are connected to those LUNs via FiberChannel Does anyone have experience with this type of mixed protocol environment, specifically with Netapp?

    Read the article

  • MSA20 RAID5 recovery failure due to URE on another disk

    - by Andrey
    I have MSA20 with one disk array on 12 disks and 3 LUNs on it (each raid 5). A few days ago one disk in one of the LUNs was failed and I replaced it. But raid5 recovering failed at 13% and I see in ADU report that one of the disk has "Errors Logged = 5566" and according SCSI specifications it is URE (Sense Code=0x11, Qualifier=0x00). In serial log I also see URE error. It seems that Raid5 can't be rebuilt because of this. So I have a few questions: Is there a way to recover raid5 still? If I leave new disk that was replaced and remove disk with URE, will other LUNs be destroyed or just failed LUN? If all LUNs will fail what is the sense to make each LUN with own raid on one disk group array if 2 failed disk can destroy all? As I understand the preferred way is to create one disk array for one LUN in future and not one array with few LUNs? Thanks.

    Read the article

  • Linux Fiber Channel Host Setup Basic

    - by Jim
    I've been googling for about 4 hours now with no luck. I am trying to setup a Linux server running Oracle Server 6.3 as a Fiber Channel host. And then connect it to a Dell Compellent Fibre Channel Host contain a 500GB Volume. The Oracle server itself contains two Brocade 815 FC HBAs. I've discovered their WWN(I think) via cat /sys/class/fc_host/host1/port_name 0x100000051efc3d85 cat /sys/class/fc_host/host2/port_name 0x100000051efc3d9f The next part is where I am at a loss. I've used iSCSI before...is FC the same deal where you have an initiator and a target? If so where do I specific that in linux? I'm also new to Fiber Channel as a protocol, so i am unsure what is needed to make a transaction? WWN and port ID? Similar to IP:Port combination in the Ethernet world. I've read alot regarding using systool, multipath, fc_transport commands, however none of these is recognized as a valid command from Oracle Server 6.3 Appreciate the guidance and assistance. I installed sccsi-target-utils and can now run rescan-scsi-bus and sg_map -x. rescan-scsi-bus.sh -l -w -r Host adapter 0 (megaraid_sas) found. Host adapter 1 ((null)) found. Host adapter 2 ((null)) found. Host adapter 3 (ata_piix) found. Host adapter 4 (ata_piix) found. Scanning SCSI subsystem for new devices and remove devices that have disappeared Scanning host 0 for SCSI target IDs 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15, LUNs 0 1 2 3 4 5 6 7 Scanning for device 0 2 0 0 .... OLD: Host: scsi0 Channel: 02 Id: 00 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning for device 0 2 1 0 ... OLD: Host: scsi0 Channel: 02 Id: 01 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 1 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 1 0 3 1 ... OLD: Host: scsi1 Channel: 00 Id: 03 Lun: 01 Vendor: COMPELNT Model: Compellent Vol Rev: 0505 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 2 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning host 3 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 3 0 0 0 ... REM: Host: scsi3 Channel: 00 Id: 00 Lun: 00 DEL: Vendor: TEAC Model: DVD-ROM DV-28SW Rev: R.2A Type: CD-ROM ANSI SCSI revision: 05 Scanning host 4 channels 0 for SCSI target IDs 0, LUNs 0 1 2 3 4 5 6 7 0 new device(s) found. 1 device(s) removed. and sg_map -x /dev/sg0 0 0 32 0 13 /dev/sg1 0 2 0 0 0 /dev/sda /dev/sg2 0 2 1 0 0 /dev/sdb /dev/sg4 1 0 3 1 0 /dev/sdc I'm not sure what this all means...

    Read the article

  • Cannot increase Datastore

    - by k4w4zz
    Hello, We have an ESX 4.0 cluster with 2 hosts, EMC Clarion SAN storage with 10 LUNs. We have added 2 new 400 GB LUNs. All the LUNs are visible from both hosts. I have extended an existing 500 GB datastore with one of these 400 GB LUNs - the new datastore size is now 900 GB. I'd like to do the same operation with the second 400 GB LUN to extend another existing datastore but I'm not able to do it. The LUN is available to create a brand new datastore but is not visible to extend an existing one. I don't understand why everything was fine with the other one and why can't I do the same exact operation with this LUN. The result is the same on both hosts. The SAN admin have erased and re-created several times this LUN. I have rescan the HBA each time. In attachment you can find the result of the esxcfg-mpath -l and fdisk -l commands on both servers. Does somebody have an idea please?

    Read the article

  • How to block some disks from probes on Linux boot?

    - by Igor Velkov
    My linux host connected to SAN with FC interface. It connect with one path, and see some luns, that can't access, because they need anohter path, not available to host. On boot linux probe all lun he can see, get read error on unaccessible luns, and hangs there for a long-long time. Is there a way to disable any access to some luns at boot time, and later? I found a filters for device ignoration for LVM and MULTIPATH, but it not help during boot process. Generally, lvm still affected too despite of filter, and gives me a IO error on every operation like lvdisplay and vgdisplay, but this is another question.

    Read the article

  • Apple XRaid questions

    - by luckytaxi
    I inherited an environment with a couple of apple xraid san. 1 - I have a 14 drive setup that's split into 5 LUNs on EACH side. The SAN goes into a fibre switch along w/ the servers that are attached to it. LUN masking is enabled on the SAN and as far as I know, there aren't any zoning on the fibre switch. Question, I have a server that's assigned two LUNs, one from each side of the controller. For some reason, it only sees one LUN (from the upper controller) and it doesn't see the one from the lower controller. The controller seems to be working fine as I have other servers attached to LUNs on the lower controller. 2 - I see a little "disclaimer" saying that any changes to the xraid will result in a reboot. So, if I add/remove hosts, this thing is going to reboot?!?!?!

    Read the article

  • Splitting Multiple Files in Windows

    - by Justin Boucher
    We have a 21TB LUN full of images that are approx 600K in size in multiple sub folders on the disk. We are trying to split the 21TB LUN into 8 smaller LUNs that are about 2.6TB a piece in order to process the images more effectively. My question is how we can determine what 2.6TB is on the drive? What is the best tool to mark this data so we can copy it to the new smaller LUNs with robocopy or emcopy without overfilling the smaller LUNs? Is there a third-party tool that would be better suited for this task? Thank you in advance for your assistance.

    Read the article

  • Replication - between pools in the same system

    - by Steve Tunstall
    OK, I fully understand that's it's been a LONG time since I've blogged with any tips or tricks on the ZFSSA, and I'm way behind. Hey, I just wrote TWO BLOGS ON THE SAME DAY!!! Make sure you keep scrolling down to see the next one too, or you may have missed it. To celebrate, for the one or two of you out there who are still reading this, I got something for you. The first TWO people who make any comment below, with your real name and email so I can contact you, will get some cool Oracle SWAG that I have to give away. Don't get excited, it's not an iPad, but it pretty good stuff. Only the first two, so if you already see two below, then settle down. Now, let's talk about Replication and Migration.  I have talked before about Shadow Migration here: https://blogs.oracle.com/7000tips/entry/shadow_migrationShadow Migration lets one take a NFS or CIFS share in one pool on a system and migrate that data over to another pool in the same system. That's handy, but right now it's only for file systems like NFS and CIFS. It will not work for LUNs. LUN shadow migration is a roadmap item, however. So.... What if you have a ZFSSA cluster with multiple pools, and you have a LUN in one pool but later you decide it's best if it was in the other pool? No problem. Replication to the rescue. What's that? Replication is only for replicating data between two different systems? Who told you that? We've been able to replicate to the same system now for a few code updates back. These instructions below will also work just fine if you're setting up replication between two different systems. After replication is complete, you can easily break replication, change the new LUN into a primary LUN and then delete the source LUN. Bam. Step 1- setup a target system. In our case, the target system is ourself, but you still have to set it up like it's far away. Go to Configuration-->Services-->Remote Replication. Click the plus sign and setup the target, which is the ZFSSA you're on now. Step 2. Now you can go to the LUN you want to replicate. Take note which Pool and Project you're in. In my case, I have a LUN in Pool2 called LUNp2 that I wish to replicate to Pool1.  Step 3. In my case, I made a Project called "Luns" and it has LUNp2 inside of it. I am going to replicate the Project, which will automatically replicate all of the LUNs and/or Filesystems inside of it.  Now, you can also replicate from the Share level instead of the Project. That will only replicate the share, and not all the other shares of a project. If someone tells you that if you replicate a share, it always replicates all the other shares also in that Project, don't listen to them.Note below how I can choose not only the Target (which is myself), but I can also choose which Pool to replicate it to. So I choose Pool1.  Step 4. I did not choose a schedule or pick the "Continuous" button, which means my replication will be manual only. I can now push the Manual Replicate button on my Actions list and you will see it start. You will see both a barber pole animation and also an update in the status bar on the top of the screen that a replication event has begun. This also goes into the event log.  Step 5. The status bar will also log an event when it's done. Step 6. If you go back to Configuration-->Services-->Remote Replication, you will see your event. Step 7. Done. To see your new replica, go to the other Pool (Pool1 for me), and click the "Replica" area below the words "Filesystems | LUNs" Here, you will see any replicas that have come in from any of your sources. It's a simple matter from here to break the replication, which will change this to a "Local" LUN, and then delete the original LUN back in Pool2. Ok, that's all for now, but I promise to give out more tricks sometime in November !!! There's very exciting stuff coming down the pipe for the ZFSSA. Both new hardware and new software features that I'm just drooling over. That's all I can say, but contact your local sales SC to get a NDA roadmap talk if you want to hear more.   Happy Halloween,Steve 

    Read the article

  • Article about Sun ZFS Storage Appliances

    - by Owen Allen
    Sun ZFS Storage Appliances are versatile storage systems. Discovering and managing them in Ops Center, though, makes them even more versatile. If you discover a Sun ZFS Storage Appliance in Ops Center 12c, you can create iSCSI and Fibre Channel LUNS, and make the LUNs available to server pools and virtualization hosts as a storage library. Barbara Higgins has written an excellent article that walks you through the process of setting up a Sun ZFS Storage Appliance and discovering and managing it in Ops Center. If you're looking into ways to make a Sun ZFS Storage Appliance work for you, it's worth a look.

    Read the article

  • ESXi 4.1 host not recognising existing VMFS datastore

    - by Graeme Donaldson
    Existing setup: host1 and host2, ESX 4.0, 2 HBAs each. lun1 and lun2, 2 LUNs belonging to the same RAID set (my terminology might be sketchy here). This has been working just fine all along. I added host3, ESXi 4.1, 2 HBAs. If I view Configuration / Storage Adapters, I can see that both HBAs see both LUNs, but if I view Configuration / Storage, I only see 1 datastore. host1/2 can see both LUNs and I have VMs running on both too. I have rescanned, refreshed and even rebooted, but host3 refuses to acknowledge 1 of the datastores. Does anyone know what's going on? Update: I re-installed the host with ESX (not i) 4.0, same version as the existing hosts and it's still not recognising the vmfs. I think I'm going to SVmotion everything off that datastore then format it. Update2: I've created the LUN from scratch and the problem gets even weirder. I've presented the LUN to all 3 hosts, and I can see the LUN in the vSphere client's Configuration / Storage Adapters section on all 3 hosts. If I create a datastore on the LUN via the Configuration / Storage section on host1, it works fine and I can create an empty folder via datastore browser, but the datastore is not seen by the host2 and host3. I can use the Add Storage wizard on host2 and it will see the LUN. At this point the "VMFS Label" column has the label I gave with "(head)" appended. If I try the Add Storage wizard's "Keep the existing signature" option, it fails with an error "Cannot change the host configuration." and a dialog box that says 'Call "HostStorageSystem.ResolveMultipleUnresolvedVmfsVolumes" for object "storageSystem-17" on vCenter Server "vcenter.company.local" failed.' If I try the Add Storage wizard's "Assign a new signature" option on host2, it will complete and the VMFS label will have "snap-(hexnumber)-" prepended. At this point its also visible on host3, but not host1. I have a similar setup in a different datacenter which didn't give me all this trouble.

    Read the article

  • ESXi 4.1 host not recognising existing VMFS datastore

    - by ThatGraemeGuy
    Existing setup: host1 and host2, ESX 4.0, 2 HBAs each. lun1 and lun2, 2 LUNs belonging to the same RAID set (my terminology might be sketchy here). This has been working just fine all along. I added host3, ESXi 4.1, 2 HBAs. If I view Configuration / Storage Adapters, I can see that both HBAs see both LUNs, but if I view Configuration / Storage, I only see 1 datastore. host1/2 can see both LUNs and I have VMs running on both too. I have rescanned, refreshed and even rebooted, but host3 refuses to acknowledge 1 of the datastores. Does anyone know what's going on? Update: I re-installed the host with ESX (not i) 4.0, same version as the existing hosts and it's still not recognising the vmfs. I think I'm going to SVmotion everything off that datastore then format it. Update2: I've created the LUN from scratch and the problem gets even weirder. I've presented the LUN to all 3 hosts, and I can see the LUN in the vSphere client's Configuration / Storage Adapters section on all 3 hosts. If I create a datastore on the LUN via the Configuration / Storage section on host1, it works fine and I can create an empty folder via datastore browser, but the datastore is not seen by the host2 and host3. I can use the Add Storage wizard on host2 and it will see the LUN. At this point the "VMFS Label" column has the label I gave with "(head)" appended. If I try the Add Storage wizard's "Keep the existing signature" option, it fails with an error "Cannot change the host configuration." and a dialog box that says 'Call "HostStorageSystem.ResolveMultipleUnresolvedVmfsVolumes" for object "storageSystem-17" on vCenter Server "vcenter.company.local" failed.' If I try the Add Storage wizard's "Assign a new signature" option on host2, it will complete and the VMFS label will have "snap-(hexnumber)-" prepended. At this point its also visible on host3, but not host1. I have a similar setup in a different datacenter which didn't give me all this trouble.

    Read the article

  • many partitions on a single filegroup?¿ does it make sense?

    - by river0
    Hi, I'm designing a datawarehouse solution and I'm a newbie in disk configuration issues, let me explain you. Our storage is spread over 6 storage enlosures having each of them 5 raid-1 disk arrays, and having 2 LUNS defined per each disk array, which makes a total 48 LUNS (this is following Microsoft fast track recommendations for datawarehouse architectures). I would like to partition my data, on other projects I have worked before, we always followed a 1 partition - 1 filegroup rule. On the microsoft fast track recomendations it is advised to create a filegroup and then for that filegroup a data file per each lun... but I pretend to have a week level partitioning... if I apply that rule I think that I'll get too many files and a complex layout. I'm thinking of just creating just one filegroup (with the 48 lun data files), but still create the partitions since I want to keep soem of the benefits of partitions like partition switching... Is this scenario not recommended? What would you suggest?

    Read the article