  • Battery Power when running Ubuntu 14.04 LTS in dual boot

    - by Amro A.
    This is only a general question in order for me to get a better idea of my dual boot (windows 8 & Ubuntu) systems. I noticed that every time I run Ubuntu (which is becoming more often) the battery power gets consumed really fast. I am not performing any special tasks at the moment, just getting to know the system, for example, sound settings, watching videos, surfing the net and so on. When I do the same thing in Windows 8 the battery lives a considerable amount of time longer. Is this something to do with Ubuntu or is it because of the dual boot that I have going on? In other words, if I start running Ubuntu all by itself on my laptop, will it be more power consuming than Windows 8?

    Read the article

  • SQL SERVER – Quiz and Video – Introduction to Basics of a Query Hint

    - by pinaldave
    This blog post is inspired from SQL Architecture Basics Joes 2 Pros: Core Architecture concepts – SQL Exam Prep Series 70-433 – Volume 3. [Amazon] | [Flipkart] | [Kindle] | [IndiaPlaza] This is follow up blog post of my earlier blog post on the same subject - SQL SERVER – Introduction to Basics of a Query Hint – A Primer. In the article we discussed various basics terminology of the query hints. The article further covers following important concepts of query hints. Expecting Seek and getting a Scan Creating an index for improved optimization Implementing the query hint Above three are the most important concepts related to query hint and SQL Server.  There are many more things one has to learn but without beginners fundamentals one can’t learn the advanced  concepts. Let us have small quiz and check how many of you get the fundamentals right. Quiz 1) You have the following query: DECLARE @UlaChoice TinyInt SET @Type = 1 SELECT * FROM LegalActivity WHERE UlaChoice = @UlaChoice You have a nonclustered index named IX_Legal_Ula on the UlaChoice field. The Primary key is on the ID field and called PK_Legal_ID 99% of the time the value of the @UlaChoice is set to ‘YP101′. What query will achieve the best optimization for this query? SELECT * FROM LegalActivity WHERE UlaChoice = @UlaChoice WITH(INDEX(X_Legal_Ula)) SELECT * FROM LegalActivity WHERE UlaChoice = @UlaChoice WITH(INDEX(PK_Legal_ID)) SELECT * FROM LegalActivity WHERE UlaChoice = @UlaChoice OPTION (Optimize FOR(@UlaChoice = ‘YP101′)) 2) You have the following query: SELECT * FROM CurrentProducts WHERE ShortName = ‘Yoga Trip’ You have a nonclustered index on the ShortName field and the query runs an efficient index seek. You change your query to use a variable for ShortName and now you are using a slow index scan. What query hint can you use to get the same execution time as before? WITH LOCK FAST OPTIMIZE FOR MAXDOP READONLY Now make sure that you write down all the answers on the piece of paper. Watch following video and read earlier article over here. If you want to change the answer you still have chance. Solution 1) 3 2) 4 Now compare let us check the answers and compare your answers to following answers. I am very confident you will get them correct. Available at USA: Amazon India: Flipkart | IndiaPlaza Volume: 1, 2, 3, 4, 5 Please leave your feedback in the comment area for the quiz and video. Did you know all the answers of the quiz? Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: Joes 2 Pros, PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • Power Distribution amongst connected nodes

    - by Perky
    In my game the map is represented by connected nodes, each node has a number of connected nodes. The nodes represent a system in which players can build structures and move units about. If you're familiar with Sins of a Solar Empire the game map is very similar. I want each node to be able to produce power and share it with all connected nodes. For example if A, B, C & D are all connected and produce 100 power units, then each system should have 400 power units available. If node B builds a structure that consumes 100 power units then A, B, C & D should then have 300 power units available. I've been working on this system all day and haven't been able to get it working quite the way I want. My current implementation is to first recurse through each nodes's connected node adding up the power, I keep a list of closed nodes so it doesn't loop, it's quite similar to A* actually. Pseudo code: All nodes start with the properties node.power = 0 node.basePower = 100 // could be different for each node. node.initialPower = node.basePower - function propagatePower( node, initialPower, closedNodes ) node.power += initialPower add( closedNodes, node ) connectedNodes = connected_nodes_except_from( closedNodes ) foreach node in connectedNodes do propagatePower( node, initialPower, closedNodes ) end end After this I iterate through all power consumers. foreach consumer in consumers do node = consumer.parentNode if node.power >= consumer.powerConsumption then consumer.powerConsumed += consumer.powerConsumption node.producedPower -= consumer.powerConsumption end end Then I adjust the initial power for the next propagation cycle. foreach node in nodes do node.initialPower = node.basePower - node.producedPower node.displayPower = node.power // for rendering the power. node.power = 0 end This seemed to work at first but then I came into a problem. Say two nodes A & B produce 100Pu each, it's shared so both A & B have 200Pu. I then make two structures that consume 80Pu each on A (160Pu). Then the nodes power is adjusted to basePower - producedPower (100-160 = -60). Nodes are propagated, both nodes now have 40Pu (A: -60 + B: 100 = 40). Which is correct because they started with 200Pu - 160Pu = 40Pu. However now node.power >= consumer.powerConsumption is false. Whats worse is it's false for any structure that uses more that 40Pu, so the whole system goes down. I could deduct from consumer.powerConsumption but what do I do if power is reduced elsewhere? I don't have the correct data to perform the necessary checks. It's late so I'm probably not thinking straight but I thought to ask on here to see if anyone has any other implementations, better or worse I'd be interested to know.

    Read the article

  • Low Power Speed Monitoring

    - by user555584
    I am aware of speed detection via gps, however as a background app, I am concerned about high power drain. I am looking to detect speed, say over 5mph, but it does not have to be accurate, say like a speedometer. Is there a low power way to detect if the phone is in motion, say by triangulation, or tracking tower strength and new/recently lost towers? I have an app design that is dependent on running in the background upon launch and knowing if the phone is in a car or not. Thanks!

    Read the article

  • Olympics data available for all on Windows Azure SQL Database and Power View

    - by jamiet
    Are you looking around for some decent test data for your BI demos? Well, if so, Microsoft have provided some data about all medals won at the Olympics Games (1900 to 2008) at OlympicsData workbook - Excel, SSIS, Azure sample; it provides analysis over athletes, countries, medal type, sport, discipline and various other dimensions. The data has been provided in an Excel workbook along with instructions on how to load the data into a Windows Azure SQL Database using SQL Server Integration Services (SSIS). Frankly though, the rigmarole of standing up your own Windows Azure SQL Database ok, SQL Azure database, is both costly (SQL Azure isn’t free) and time consuming (the provided instructions aren’t exactly an idiot’s guide and getting SSIS to work properly with Excel isn’t a barrel of laughs either). To ease the pain for all you BI folks out there that simply want to party on the data I have loaded it all into the SQL Azure database that I use for hosting AdventureWorks on Azure. You can read more about AdventureWorks on Azure below however I’ll summarise here by saying it is a SQL Azure database provided for the use of the SQL Server community and which is supported by voluntary donations. To view the data the credentials you need are: Server mhknbn2kdz.database.windows.net  Database AdventureWorks2012 User sqlfamily Password sqlf@m1ly Type those into SSMS and away you go, the data is provided in four tables [olympics].[Sport], [olympics].[Discipline], [olympics].[Event] & [olympics].[Medalist]: I figured this would be a good candidate for a Power View report so I fired up Excel 2013 and built such a report to slice’n’dice through the data – here are some screenshots that should give you a flavour of what is available: A view of all the available data Where do all the gymastics medals go? Which countries do top ten all-time medal winners come from? You get the idea. There is masses of information here and if you have Excel 2013 handy Power View provides a quick and easy way of surfing through it. To save you the bother of setting up the Power View report yourself you can have the one that I took these screenshots from, it is available on my SkyDrive at OlympicsAnalysis.xlsx so just hit the link and download to play to your heart’s content. Party on, people! As I said above the data is hosted on a SQL Azure database that I use for hosting “AdventureWorks on Azure” which I first announced in March 2013 at AdventureWorks2012 now available for all on SQL Azure. I’ll repeat the pertinent parts of that blog post here: I am pleased to announce that as of today … [AdventureWorks2012] now resides on SQL Azure and is available for anyone, absolutely anyone, to connect to and use for their own means. This database is free for you to use but SQL Azure is of course not free so before I give you the credentials please lend me your ears eyes for a short while longer. AdventureWorks on Azure is being provided for the SQL Server community to use and so I am hoping that that same community will rally around to support this effort by making a voluntary donation to support the upkeep which, going on current pricing, is going to be $119.88 per year. If you would like to contribute to keep AdventureWorks on Azure up and running for that full year please donate via PayPal to [email protected] Any amount, no matter how small, will help. If those 50+ people that retweeted me beforehand all contributed $2 then that would just about be enough to keep this up for a year. If the community contributes more than we need then there are a number of additional things that could be done: Host additional databases (Northwind anyone??) Host in more datacentres (this first one is in Western Europe) Make a charitable donation That last one, a charitable donation, is something I would really like to do. The SQL Community have proved before that they can make a significant contribution to charitable orgnisations through purchasing the SQL Server MVP Deep Dives book and I harbour hopes that AdventureWorks on Azure can continue in that vein. So please, if you think AdventureWorks on Azure is something that is worth supporting please make a contribution. I’d like to emphasize that last point. If my hosting this Olympics data is useful to you please support this initiative by donating. Thanks in advance. @Jamiet

    Read the article

  • Why does working processors harder use more electrical power?

    - by GazTheDestroyer
    Back in the mists of time when I started coding, at least as far as I'm aware, processors all used a fixed amount of power. There was no such thing as a processor being "idle". These days there are all sorts of technologies for reducing power usage when the processor is not very busy, mostly by dynamically reducing the clock rate. My question is why does running at a lower clock rate use less power? My mental picture of a processor is of a reference voltage (say 5V) representing a binary 1, and 0V representing 0. Therefore I tend to think of of a constant 5V being applied across the entire chip, with the various logic gates disconnecting this voltage when "off", meaning a constant amount of power is being used. The rate at which these gates are turned on and off seems to have no relation to the power used. I have no doubt this is a hopelessly naive picture, but I am no electrical engineer. Can someone explain what's really going on with frequency scaling, and how it saves power. Are there any other ways that a processor uses more or less power depending on state? eg Does it use more power if more gates are open? How are mobile / low power processors different from their desktop cousins? Are they just simpler (less transistors?), or is there some other fundamental design difference?

    Read the article

  • SQL SERVER – Discard Results After Query Execution – SSMS

    - by pinaldave
    The first thing I do any day is to turn on the computer. Today I woke up and as soon as I turned on the computer I saw a chat message from a friend. He was a bit confused and wanted me to help him. Just as usual I am keeping the relevant conversation in focus and documenting our conversation as chat. Let us call him Ajit. Ajit: Pinal, every time I run a query there is no result displayed in the SSMS but when I run the query in my application it works and returns an appropriate result. Pinal:  Have you tried with different parameters? Ajit: Same thing. However, it works from another computer when I connect to the same server with the same query parameters? Pinal: What? That is new and I believe it is something to do with SSMS and not with the server. Send me screenshot please. Ajit: I believe so, let me send you a screenshot, Pinal: (looking at the screenshot) Oh man, there is no result-tab at all. Ajit: That is what the problem is. It does not have the tab which displays the result. This works just fine from another computer. Pinal: Have you referred Nakul’s blog post – SSMS – Query result options – Discard result after query executes, that talks about setting which can discard the query results after execution. (After a while) Ajit: I think it seems like on the computer where I am running the query my SSMS seems to have the option enabled related to discarding results. I fixed it by following Nakul’s blog post. Pinal: Great! Quite often I get the question what is the importance of the feature. Let us first see how to turn on or turn off this feature in SQL Server Management Studio 2012. In SSMS 2012 go to Tools >> Options >> Query Results > SQL Server >> Results to Grid >> Discard Results After Query Execution. When enabled this option will discard results after the execution. The advantage of disabling the option is that it will improve the performance by using less memory. However the real question is why would someone enable or disable the option. What are the cases when someone wants to run the query but do not care about the result? Matter of the fact, it does not make sense at all to run query and not care about the result. The matter of the fact, I can see quite a few reasons for using this option. I often enable this option when I am doing performance tuning exercise. During performance tuning exercise when I am working with execution plans and do not need results to verify every time or when I am tuning Indexes and its effect on execution plan I do not need the results. In this kind of situations I do keep this option on and discard the results. It always helps me big time as in most of the performance tuning exercise I am dealing with huge amount of the data and dealing with this data can be expensive. Nakul’s has done the experiment here already but I am going to repeat the same again using AdventureWorks Database. Run following T-SQL Script with and without enabling the option to discard the results. USE AdventureWorks2012 GO SELECT * FROM Sales.SalesOrderDetail GO 10 After enabling Discard Results After Query Execution After disabling Discard Results After Query Execution Well, this is indeed a good option when someone is debugging the execution plan or does not want the result to be displayed. Please note that this option does not reduce IO or CPU usage for SQL Server. It just discards the results after execution and a good help for debugging on the development server. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Server Management Studio, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • Laptop power supplies, does current matter?

    - by CodeSlave
    I have two laptops (same manufacture), with the same type of power connector. However, the power supplies/transformers are slightly different. The output on the first laptop's power supply is 15.6 V at 8.0 A. The output on the second laptop's power supply is 15.6 V at 5A. Clearly the voltages are the same, but the currents are different. I assume the second laptop's power supply can not be used on the first, because it can't supply enough power to the laptop. However, can the first laptop's power supply be safely used on the second laptop?

    Read the article

  • Will final version of 12.04 use the power management changes found in kernel 3.3

    - by Luis Alvarado
    I have seen in some version of Ubuntu that instead of making a huge change to update to the latest kernel, they take some of the good stuff out of it, for the sake of stability and put it on a previous version. In this case, kernel 3.3 has seen some very good power management enhancements that are not all found in the kernel 3.2. My question then is: Will this updates in 3.3 be somehow pulled into the 3.2 kernel used for Ubuntu 12.04?

    Read the article

  • power management of USB-enclosed hard drives

    - by intuited
    With a typical USB hard drive enclosure, is the full range of drive power management functionality available? In what may be an unrelated matter: is it possible to suspend a PC without unmounting an attached USB-powered drive, and then remounting it on resume? This is the behaviour I'm currently seeing (running Ubuntu linux 10.10). Are there certain models or brands that provide more complete control over this aspect of drive operation? My Friendly Neighbourhood Computer Store carries (part of) the Vantec Nexstar product line.

    Read the article

  • Power manager keeps shutting down the display

    - by david25
    I'm probably missing something here. I'm using the default Ubuntu power manger, I set it up like this: On AC: no screen dimming when idle, never put computer to sleep, never put display to sleep. On battery: I kept the default settings. Still, Ubuntu does whatever it likes, and after 15 min it puts the display to sleep. Does anyone have the same problem and found a way to solve it? I'm using an Eee PC with Ubuntu 10.10 Desktop.

    Read the article

  • Xubuntu 14.04, Power Manager, Screensaver

    - by Bathynomus
    When my computer is inactive, I keep getting a black screen and the screen goes into locked mode asking for a password, even though in Power Manager I have "Never" set for actions and monitor and Extended "Lock Screen" is unchecked. I don't see a screensaver, but perhaps that is the issue? Is anyone else experiencing this? Is this a bug? Is there a temporary workaround? I did not see this issue in 12.xx, 13.xx.

    Read the article

  • SQL server recursive query error.The maximum recursion 100 has been exhausted before statement completion

    - by ienax_ridens
    I have a recursive query that returns an error when I run it; in other databases (with more data) I have not the problem. In my case this query returns 2 colums (ID_PARENT and ID_CHILD) doing a recursion because my tree can have more than one level, bit I wanna have only "direct" parent. NOTE: I tried to put OPTION (MAXRECURSION 0) at the end of the query, but with no luck. The following query is only a part of the entire query, I tried to put OPTION only at the end of the "big query" having a continous running query, but no errors displayed. Error have in SQL Server: "The statement terminated.The maximum recursion 100 has been exhausted before statement completion" The query is the following: WITH q AS (SELECT ID_ITEM, ID_ITEM AS ID_ITEM_ANCESTOR FROM ITEMS_TABLE i JOIN ITEMS_TYPES_TABLE itt ON itt.ID_ITEM_TYPE = i.ID_ITEM_TYPE UNION ALL SELECT i.ID_ITEM, q.ID_ITEM_ANCESTOR FROM q JOIN ITEMS_TABLE i ON i.ID_ITEM_PADRE = q.ID_ITEM JOIN ITEMS_TYPES_TABLE itt ON itt.ID_ITEM_TYPE = i.ID_ITEM_TYPE) SELECT ID_ITEM AS ID_CHILD, ID_ITEM_ANCESTOR AS ID_PARENT FROM q I need a suggestion to re-write this query to avoid the error of recursion and see the data, that are few.

    Read the article

  • How to prevent screen locking when lid is closed?

    - by Joe Casadonte
    I have Ubuntu 11.10 with Gnome 3 (no Unity), gnome-screen-saver has been removed and replaced with xscreensaver. The screensaver stuff all works fine -- no complaints there. When I close my laptop lid, even for a second, the screen locks (and the dialog box asking for my password is xscreensaver's). I'd like for this not to happen... Things I've tried/looked at already: xscreensaver settings - the "Lock Screen After" checkbox is not checked (though I've also tried it checked and set to 720 minutes) gconf-editor - apps -> gnome-screensaver -> lock_enabled is not checked System Settings - Power - "When the lid is closed" is set to "Do nothing" for both battery and A/C System Settings - Screen - Lock is "off" gconf-editor - apps -> gnome-power-manager -> buttons -> lid_ac && lid_battery are both set to "nothing" dconf-editor - apps -> org -> gnome -> desktop -> screensaver -> lock_enabled is not checked Output from: gsettings list-recursively org.gnome.settings-daemon.plugins.power: org.gnome.settings-daemon.plugins.power active true org.gnome.settings-daemon.plugins.power button-hibernate 'hibernate' org.gnome.settings-daemon.plugins.power button-power 'suspend' org.gnome.settings-daemon.plugins.power button-sleep 'suspend' org.gnome.settings-daemon.plugins.power button-suspend 'suspend' org.gnome.settings-daemon.plugins.power critical-battery-action 'hibernate' org.gnome.settings-daemon.plugins.power idle-brightness 30 org.gnome.settings-daemon.plugins.power idle-dim-ac false org.gnome.settings-daemon.plugins.power idle-dim-battery true org.gnome.settings-daemon.plugins.power idle-dim-time 10 org.gnome.settings-daemon.plugins.power lid-close-ac-action 'nothing' org.gnome.settings-daemon.plugins.power lid-close-battery-action 'nothing' org.gnome.settings-daemon.plugins.power notify-perhaps-recall true org.gnome.settings-daemon.plugins.power percentage-action 2 org.gnome.settings-daemon.plugins.power percentage-critical 3 org.gnome.settings-daemon.plugins.power percentage-low 10 org.gnome.settings-daemon.plugins.power priority 1 org.gnome.settings-daemon.plugins.power sleep-display-ac 600 org.gnome.settings-daemon.plugins.power sleep-display-battery 600 org.gnome.settings-daemon.plugins.power sleep-inactive-ac false org.gnome.settings-daemon.plugins.power sleep-inactive-ac-timeout 0 org.gnome.settings-daemon.plugins.power sleep-inactive-ac-type 'suspend' org.gnome.settings-daemon.plugins.power sleep-inactive-battery true org.gnome.settings-daemon.plugins.power sleep-inactive-battery-timeout 0 org.gnome.settings-daemon.plugins.power sleep-inactive-battery-type 'suspend' org.gnome.settings-daemon.plugins.power time-action 120 org.gnome.settings-daemon.plugins.power time-critical 300 org.gnome.settings-daemon.plugins.power time-low 1200 org.gnome.settings-daemon.plugins.power use-time-for-policy true gnome-settings-daemon is running: <~> $ ps -ef | grep gnome-settings-daemon 1000 1719 1645 0 19:37 ? 00:00:01 /usr/lib/gnome-settings-daemon/gnome-settings-daemon 1000 1726 1 0 19:37 ? 00:00:00 /usr/lib/gnome-settings-daemon/gsd-printer 1000 1774 1645 0 19:37 ? 00:00:00 /usr/lib/gnome-settings-daemon/gnome-fallback-mount-helper Anything else I can check? Thanks!

    Read the article

  • Melting Laptop Power Supply Tip

    - by AlReece45
    Several (6-7) months ago, my laptop power supply cord got a cut in it and stopped working. Having gotten cheap (and short) power supplies in the past, I decided to buy 2 brand new ones from the manufacturer (ASUS). Now, I used my laptop a little less than usual between February and March. During that time I noticed a few times that the power supply, even though plugged in, did not provide power. Often the computer would just off on me. I figured it was just that one power supply being bad. I had left the alternate at my parent's house in another state and asked them to ship it to me. Now, at work the other day I wanted to get a file off the of hard disk. So I booted it up, knowing that it had a low battery, plugged it in. During the first 2 minutes of use, I was told that the battery was low and I should plug it in. I unplugged it, inspected the end (Being plugged in, this was suspicious), and decided I shouldn't plug it back in-- the plastic on the tip was melting from the heat of the metal on the tip. The computer had simply booted up and I had the file-manager open. It had not been on for more than 10 hours. Now I know that computers tend to get pretty hot. However, the melting point of plastic is usually above 200C.. so that's much hotter than the computer should be generating. I went and bought a THIRD power supply. This time a universal one from Best Buy (it was very fast to buy and test). I tried it out on the computer and it's tip is melting as well. My older laptop that uses the universal power supply uses it perfectly (has been about a week and a part of use now). I have tried using the computer without the battery, with the same effect. Obviously, this is not a problem with the power supply. My room mate and I being trained computer techs were contemplating taking the computer apart and desoldering and resoldering on the power tip. (The computer is about 6 months out of its 2-year warranty). We're hoping that will correct the issue as I would prefer to devote my money on a Good Desktop rather than yet ANOTHER $1200+ laptop. Is there any thing I'm missing here that might cause the the tip on the power unit to melt?

    Read the article

  • Power Supply And Power Cable at Equinix Palo Alto?

    - by d123
    I will be doing a server installation at the Palo Alto Equinix Data Center soon and I'm coming in from overseas so I wondering if any of you can help me out regarding power supply can power cable issues. My server power supply is INPUT 100-240V AC ~50/60Hz MAX AC CURRENT 10A-5A Do I need a DC power supply? and the power cable plug head I'm currently using is BS 1363 plug head. What kind of head do I need?

    Read the article

  • Shaping the Future of Power

    - by caroline.yu
    In an energy marketplace that continues to evolve, gain insight into how utility executives increasingly confront the challenges of preparing their workers, regulators and customers for a period of volatility and promise. This free on-demand Web cast, sponsored and underwritten by Oracle Utilities, will provide you with an executive-level view of what it means and takes to be a utility leader. By viewing this Web cast, you will hear: NRG's CEO David Crane weighing in on next-gen nuclear, generation portfolio diversity, and what it's like to live through (and thrive in) a hostile takeover attempt EPRI's Clark Gellings, the father of demand side management, outlining the coming trends marrying technology with customer energy consumption patterns CEO Ralph Izzo discussing PSEG's low-carbon emissions strategy, commitment to solar power development, and pursuit of reliability through infrastructure investment. To view this Web cast, please follow this link.

    Read the article

  • Power management issues on an Asus N55

    - by Andrea Borga
    I noticed that with respect to Win7 on my Asus N55 Ubuntu 12.04 tend to overheat the system. After startup the fan controller takes control of the fan, I could here it slowing down, after a few second following a login the fan increases its speed again. Though there are no processor hungry process: top shows only Xorg consuming 4%. Even with the system monitor the CPUs load look ok. Is it a power management related problem? This can cause battery life troubles in general, and electronics is never happy to be overheated. Is there a better tool to root the cause of the issue?

    Read the article

  • Cutting desktop power usage

    - by steevc
    I'm on a general energy saving mission. I've finally swapped my old CRT monitor for a LCD, so the next step it to optimise the PC power usage. It's using an AMD 64 X2 4600+ CPU which I know can trottle down, but seems to be running at a constant 2.4GHz. A while back I heard about Granola. I've installed it, but when I try to run it I get granola[10568]: Error opening scaling governor file '/sys/devices/system/cpu/cpu0/cpufreq/scaling_governor' in read mode granola[10568]: Is cpufreq enabled in this kernel and do you have a CPU which supports DVFS? granola[10568]: Can't manage DVFS for any CPUs I'm happy to use other applications if Granola is not optimal or viable.

    Read the article

  • power manger keeps on shuting down the display even when i state in the power manger to never do that.

    - by david25
    i'm probably missing something here, i'm using the default ubuntu power manger, i setup it like that: on AC: no screen dimming when ideal. never put computer to sleep. never put display to sleep. on battery i kept the default setting. and still ubuntu does what ever it likes :\ , after 15 min it puts the display to sleep. any one having the same problem and found a way to bypass it? im using eee pc with ubuntu 10.10 desktop.

    Read the article

  • SQL SERVER – Faster SQL Server Databases and Applications – Power and Control with SafePeak Caching Options

    - by Pinal Dave
    Update: This blog post is written based on the SafePeak, which is available for free download. Today, I’d like to examine more closely one of my preferred technologies for accelerating SQL Server databases, SafePeak. Safepeak’s software provides a variety of advanced data caching options, techniques and tools to accelerate the performance and scalability of SQL Server databases and applications. I’d like to look more closely at some of these options, as some of these capabilities could help you address lagging database and performance on your systems. To better understand the available options, it is best to start by understanding the difference between the usual “Basic Caching” vs. SafePeak’s “Dynamic Caching”. Basic Caching Basic Caching (or the stale and static cache) is an ability to put the results from a query into cache for a certain period of time. It is based on TTL, or Time-to-live, and is designed to stay in cache no matter what happens to the data. For example, although the actual data can be modified due to DML commands (update/insert/delete), the cache will still hold the same obsolete query data. Meaning that with the Basic Caching is really static / stale cache.  As you can tell, this approach has its limitations. Dynamic Caching Dynamic Caching (or the non-stale cache) is an ability to put the results from a query into cache while maintaining the cache transaction awareness looking for possible data modifications. The modifications can come as a result of: DML commands (update/insert/delete), indirect modifications due to triggers on other tables, executions of stored procedures with internal DML commands complex cases of stored procedures with multiple levels of internal stored procedures logic. When data modification commands arrive, the caching system identifies the related cache items and evicts them from cache immediately. In the dynamic caching option the TTL setting still exists, although its importance is reduced, since the main factor for cache invalidation (or cache eviction) become the actual data updates commands. Now that we have a basic understanding of the differences between “basic” and “dynamic” caching, let’s dive in deeper. SafePeak: A comprehensive and versatile caching platform SafePeak comes with a wide range of caching options. Some of SafePeak’s caching options are automated, while others require manual configuration. Together they provide a complete solution for IT and Data managers to reach excellent performance acceleration and application scalability for  a wide range of business cases and applications. Automated caching of SQL Queries: Fully/semi-automated caching of all “read” SQL queries, containing any types of data, including Blobs, XMLs, Texts as well as all other standard data types. SafePeak automatically analyzes the incoming queries, categorizes them into SQL Patterns, identifying directly and indirectly accessed tables, views, functions and stored procedures; Automated caching of Stored Procedures: Fully or semi-automated caching of all read” stored procedures, including procedures with complex sub-procedure logic as well as procedures with complex dynamic SQL code. All procedures are analyzed in advance by SafePeak’s  Metadata-Learning process, their SQL schemas are parsed – resulting with a full understanding of the underlying code, objects dependencies (tables, views, functions, sub-procedures) enabling automated or semi-automated (manually review and activate by a mouse-click) cache activation, with full understanding of the transaction logic for cache real-time invalidation; Transaction aware cache: Automated cache awareness for SQL transactions (SQL and in-procs); Dynamic SQL Caching: Procedures with dynamic SQL are pre-parsed, enabling easy cache configuration, eliminating SQL Server load for parsing time and delivering high response time value even in most complicated use-cases; Fully Automated Caching: SQL Patterns (including SQL queries and stored procedures) that are categorized by SafePeak as “read and deterministic” are automatically activated for caching; Semi-Automated Caching: SQL Patterns categorized as “Read and Non deterministic” are patterns of SQL queries and stored procedures that contain reference to non-deterministic functions, like getdate(). Such SQL Patterns are reviewed by the SafePeak administrator and in usually most of them are activated manually for caching (point and click activation); Fully Dynamic Caching: Automated detection of all dependent tables in each SQL Pattern, with automated real-time eviction of the relevant cache items in the event of “write” commands (a DML or a stored procedure) to one of relevant tables. A default setting; Semi Dynamic Caching: A manual cache configuration option enabling reducing the sensitivity of specific SQL Patterns to “write” commands to certain tables/views. An optimization technique relevant for cases when the query data is either known to be static (like archive order details), or when the application sensitivity to fresh data is not critical and can be stale for short period of time (gaining better performance and reduced load); Scheduled Cache Eviction: A manual cache configuration option enabling scheduling SQL Pattern cache eviction based on certain time(s) during a day. A very useful optimization technique when (for example) certain SQL Patterns can be cached but are time sensitive. Example: “select customers that today is their birthday”, an SQL with getdate() function, which can and should be cached, but the data stays relevant only until 00:00 (midnight); Parsing Exceptions Management: Stored procedures that were not fully parsed by SafePeak (due to too complex dynamic SQL or unfamiliar syntax), are signed as “Dynamic Objects” with highest transaction safety settings (such as: Full global cache eviction, DDL Check = lock cache and check for schema changes, and more). The SafePeak solution points the user to the Dynamic Objects that are important for cache effectiveness, provides easy configuration interface, allowing you to improve cache hits and reduce cache global evictions. Usually this is the first configuration in a deployment; Overriding Settings of Stored Procedures: Override the settings of stored procedures (or other object types) for cache optimization. For example, in case a stored procedure SP1 has an “insert” into table T1, it will not be allowed to be cached. However, it is possible that T1 is just a “logging or instrumentation” table left by developers. By overriding the settings a user can allow caching of the problematic stored procedure; Advanced Cache Warm-Up: Creating an XML-based list of queries and stored procedure (with lists of parameters) for periodically automated pre-fetching and caching. An advanced tool allowing you to handle more rare but very performance sensitive queries pre-fetch them into cache allowing high performance for users’ data access; Configuration Driven by Deep SQL Analytics: All SQL queries are continuously logged and analyzed, providing users with deep SQL Analytics and Performance Monitoring. Reduce troubleshooting from days to minutes with database objects and SQL Patterns heat-map. The performance driven configuration helps you to focus on the most important settings that bring you the highest performance gains. Use of SafePeak SQL Analytics allows continuous performance monitoring and analysis, easy identification of bottlenecks of both real-time and historical data; Cloud Ready: Available for instant deployment on Amazon Web Services (AWS). As you can see, there are many options to configure SafePeak’s SQL Server database and application acceleration caching technology to best fit a lot of situations. If you’re not familiar with their technology, they offer free-trial software you can download that comes with a free “help session” to help get you started. You can access the free trial here. Also, SafePeak is available to use on Amazon Cloud. Reference: Pinal Dave (http://blog.sqlauthority.com)Filed under: PostADay, SQL, SQL Authority, SQL Performance, SQL Query, SQL Server, SQL Tips and Tricks, T SQL

    Read the article

  • PC power supply & normal range for voltages reported in BIOS hardware monitor?

    - by Chris W. Rea
    I'm trying to diagnose whether my computer has an ample power supply. Sometimes when I play a video-intensive game, both monitors lose the video signal, even though the computer remains on and sound playing. A theory I have is: the video card isn't getting sufficient power. I can't imagine it's overheating because the machine is well-ventilated and the video card isn't hot to touch when this happens. Anyway, in my PC's BIOS there's a Hardware Monitor page, and among other voltages reported (such as CPU, DRAM, South Bridge, etc.) I can see the following values: 3.3V 3.152V 5V 4.944V 12V 11.872V Are those the voltages used by peripherals? What voltage should I be referencing if I want to know what my video card (PCI Express) is consuming? What is the normal range of values reported for those? My values above appear to be under by approximately 4.5%, 1.1%, and 1.1% respectively. Is that cause for concern? How else should I be determining if my power supply is "right-sized" for my PC and video card, or am I perhaps barking up the wrong tree?

    Read the article

  • Desktop PC does not power up on power button

    - by hIpPy
    When I press the power button on my desktop, it does not power up completely. Before I press the power button, I see lights on the motherboard. Everything is normal. On power button press, the fans on the cpu, graphics card and motherboard start to spin a little for a second or two and then they stop. No beeps during this process. It has been doing this for a while now but it used to start up after some trials. Once it starts up, I have NO issues at all like random shutdowns so it is not an issue with OS. I'm just guessing here but it seems as if the PSU (Antec TP2-550ATX) is dying out and does not have enough power now - just a guess. It's an old desktop assembled in 2005 but I have maintained it well. Any ideas? Please help. Thanks. Below is the complete configuration. DFI LAN-Party UT NF4 Ultra-D 6/23 {6.70}, Evercool EC-VC-RE 41/47C, AMD Opteron 170 2.0GHz {1.3.2.16} 1.312V 36/41C, ThermalRight SI-120, Panaflo 120×38mm OCZ Platinum 2×1GB 200MHz 2.66V 3-3-2-7 1T XFX 7800GTX 256MB 475/1250MHz {91.31}, Zalman VF900 Cu led 41/56C WD Caviar 320GB 7200RPM 16MB SATA 3Gb/s Antec TP2-550ATX Antec P180 WinXP sp2 KB896256 Logitech MX310 Razer Mantis Speed BenQ FP91G+ 19" LCD 8ms DVI Creative Audigy2 ZS {4.42} BenQ DW1640 Logitech z-5300e 5.1 280W Legend: Driver versions: {} User settings: [] Voltage: V Wattage: W Temperature: C (Celsius) min/max

    Read the article

  • Desktop PC does not power up on power button

    - by hIpPy
    When I press the power button on my desktop, it does not power up completely. Before I press the power button, I see lights on the motherboard. Everything is normal. On power button press, the fans on the cpu, graphics card and motherboard start to spin a little for a second or two and then they stop. No beeps during this process. It has been doing this for a while now but it used to start up after some trials. Once it starts up, I have NO issues at all like random shutdowns so it is not an issue with OS. Update: I left the desktop off for a few days and it started. I'm just guessing here but it seems as if the PSU (Antec TP2-550ATX) is dying out and does not have enough power now - just a guess. It's an old desktop assembled in 2005 but I have maintained it well. Update: I always keep the desktop running and I never shut it down. During updates or manual restarts, it powers up without issues. I wonder if this sheds lights on the issue. Any idea how I can narrow down the issue? ex: if I can find if the PSU is dying etc. I'd really like to fix the issue. Please help. Thanks. Below is the complete configuration. DFI LAN-Party UT NF4 Ultra-D 6/23 {6.70}, Evercool EC-VC-RE 41/47C, AMD Opteron 170 2.0GHz {1.3.2.16} 1.312V 36/41C, ThermalRight SI-120, Panaflo 120×38mm OCZ Platinum 2×1GB 200MHz 2.66V 3-3-2-7 1T XFX 7800GTX 256MB 475/1250MHz {91.31}, Zalman VF900 Cu led 41/56C WD Caviar 320GB 7200RPM 16MB SATA 3Gb/s Antec TP2-550ATX Antec P180 WinXP sp3 Logitech MX310 Razer Mantis Speed BenQ FP91G+ 19" LCD 8ms DVI Creative Audigy2 ZS {4.42} BenQ DW1640 Logitech z-5300e 5.1 280W Legend: Driver versions: {} User settings: [] Voltage: V Wattage: W Temperature: C (Celsius) min/max

    Read the article

  • SQL SERVER – How to Ignore Columnstore Index Usage in Query

    - by pinaldave
    Earlier I wrote about SQL SERVER – Fundamentals of Columnstore Index and very first question I received in email was as following. “We are using SQL Server 2012 CTP3 and so far so good. In our data warehouse solution we have created 1 non-clustered columnstore index on our large fact table. We have very unique situation but your article did not cover it. We are running few queries on our fact table which is working very efficiently but there is one query which earlier was running very fine but after creating this non-clustered columnstore index this query is running very slow. We dropped the columnstore index and suddenly this one query is running fast but other queries which were benefited by this columnstore index it is running slow. Any workaround in this situation?” In summary the question in simple words “How can we ignore using columnstore index in selective queries?” Very interesting question – you can use I can understand there may be the cases when columnstore index is not ideal and needs to be ignored the same. You can use the query hint IGNORE_NONCLUSTERED_COLUMNSTORE_INDEX to ignore the columnstore index. SQL Server Engine will use any other index which is best after ignoring the columnstore index. Here is the quick script to prove the same. We will first create sample database and then create columnstore index on the same. Once columnstore index is created we will write simple query. This query will use columnstore index. We will then show the usage of the query hint. USE AdventureWorks GO -- Create New Table CREATE TABLE [dbo].[MySalesOrderDetail]( [SalesOrderID] [int] NOT NULL, [SalesOrderDetailID] [int] NOT NULL, [CarrierTrackingNumber] [nvarchar](25) NULL, [OrderQty] [smallint] NOT NULL, [ProductID] [int] NOT NULL, [SpecialOfferID] [int] NOT NULL, [UnitPrice] [money] NOT NULL, [UnitPriceDiscount] [money] NOT NULL, [LineTotal] [numeric](38, 6) NOT NULL, [rowguid] [uniqueidentifier] NOT NULL, [ModifiedDate] [datetime] NOT NULL ) ON [PRIMARY] GO -- Create clustered index CREATE CLUSTERED INDEX [CL_MySalesOrderDetail] ON [dbo].[MySalesOrderDetail] ( [SalesOrderDetailID]) GO -- Create Sample Data Table -- WARNING: This Query may run upto 2-10 minutes based on your systems resources INSERT INTO [dbo].[MySalesOrderDetail] SELECT S1.* FROM Sales.SalesOrderDetail S1 GO 100 -- Create ColumnStore Index CREATE NONCLUSTERED COLUMNSTORE INDEX [IX_MySalesOrderDetail_ColumnStore] ON [MySalesOrderDetail] (UnitPrice, OrderQty, ProductID) GO Now we have created columnstore index so if we run following query it will use for sure the same index. -- Select Table with regular Index SELECT ProductID, SUM(UnitPrice) SumUnitPrice, AVG(UnitPrice) AvgUnitPrice, SUM(OrderQty) SumOrderQty, AVG(OrderQty) AvgOrderQty FROM [dbo].[MySalesOrderDetail] GROUP BY ProductID ORDER BY ProductID GO We can specify Query Hint IGNORE_NONCLUSTERED_COLUMNSTORE_INDEX as described in following query and it will not use columnstore index. -- Select Table with regular Index SELECT ProductID, SUM(UnitPrice) SumUnitPrice, AVG(UnitPrice) AvgUnitPrice, SUM(OrderQty) SumOrderQty, AVG(OrderQty) AvgOrderQty FROM [dbo].[MySalesOrderDetail] GROUP BY ProductID ORDER BY ProductID OPTION (IGNORE_NONCLUSTERED_COLUMNSTORE_INDEX) GO Let us clean up the database. -- Cleanup DROP INDEX [IX_MySalesOrderDetail_ColumnStore] ON [dbo].[MySalesOrderDetail] GO TRUNCATE TABLE dbo.MySalesOrderDetail GO DROP TABLE dbo.MySalesOrderDetail GO Again, make sure that you use hint sparingly and understanding the proper implication of the same. Make sure that you test it with and without hint and select the best option after review of your administrator. Here is the question for you – have you started to use SQL Server 2012 for your validation and development (not on production)? It will be interesting to know the answer. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Index, SQL Optimization, SQL Performance, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology