Search Results

Search found 22756 results on 911 pages for 'power query'.

Page 5/911 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Enforcing a query in MySql to use a specific index

    - by Hossein
    Hi, I have large table. consisting of only 3 columns (id(INT),bookmarkID(INT),tagID(INT)).I have two BTREE indexes one for each bookmarkID and tagID columns.This table has about 21 Million records. I am trying to run this query: SELECT bookmarkID,COUNT(bookmarkID) AS count FROM bookmark_tag_map GROUP BY tagID,bookmarkID HAVING tagID IN (-----"tagIDList"-----) AND count >= N which takes ages to return the results.I read somewhere that if make an index in which it has tagID,bookmarkID together, i will get a much faster result. I created the index after some time. Tried the query again, but it seems that this query is not using the new index that I have made.I ran EXPLAIN and saw that it is actually true. My question now is that how I can enforce a query to use a specific index? also comments on other ways to make the query faster are welcome. Thanks

    Read the article

  • How To Delete Built-in Windows 7 Power Plans (and Why You Probably Shouldn’t)

    - by The Geek
    Do you actually use the Windows 7 power management features? If so, have you ever wanted to just delete one of the built-in power plans? Here’s how you can do so, and why you probably should leave it alone. Just in case you’re new to the party, we’re talking about the power plans that you see when you click on the battery/plug icon in the system tray. The problem is that one of the built-in plans always shows up there, even if you only use custom plans. When you go to “More power options” on the menu there, you’ll be taken to a list of them, but you’ll be unable to get rid of any of the built-in ones, even if you have your own. You can actually delete the power plans, but it will probably cause problems, so we highly recommend against it. If you still want to proceed, keep reading. Delete Built-in Power Plans in Windows 7 Open up an Administrator mod command prompt by right-clicking on the command prompt and choosing “Run as Administrator”, then type in the following command, which will show you a whole list of the plans. powercfg list Do you see that really long GUID code in the middle of each listing? That’s what we’re going to need for the next step. To make it easier, we’ll provide the codes here, just in case you don’t know how to copy to the clipboard from the command prompt. Power Scheme GUID: 381b4222-f694-41f0-9685-ff5bb260df2e  (Balanced) Power Scheme GUID: 8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c  (High performance)Power Scheme GUID: a1841308-3541-4fab-bc81-f71556f20b4a  (Power saver) Before you do any deleting, what you’re going to want to do is export the plan to a file using the –export parameter. For some unknown reason, I used the .xml extension when I did this, though the file isn’t in XML format. Moving on… here’s the syntax of the command: powercfg –export balanced.xml 381b4222-f694-41f0-9685-ff5bb260df2e This will export the Balanced plan to the file balanced.xml. And now, we can delete the plan by using the –delete parameter, and the same GUID.  powercfg –delete 381b4222-f694-41f0-9685-ff5bb260df2e If you want to import the plan again, you can use the -import parameter, though it has one weirdness—you have to specify the full path to the file, like this: powercfg –import c:\balanced.xml Using what you’ve learned, you can export each of the plans to a file, and then delete the ones you want to delete. Why Shouldn’t You Do This? Very simple. Stuff will break. On my test machine, for example, I removed all of the built-in plans, and then imported them all back in, but I’m still getting this error anytime I try to access the panel to choose what the power buttons do: There’s a lot more error messages, but I’m not going to waste your time with all of them. So if you want to delete the plans, do so at your own peril. At least you’ve been warned! Similar Articles Productive Geek Tips Learning Windows 7: Manage Power SettingsCreate a Shortcut or Hotkey to Switch Power PlansDisable Power Management on Windows 7 or VistaChange the Windows 7 or Vista Power Buttons to Shut Down/Sleep/HibernateDisable Windows Vista’s Built-in CD/DVD Burning Features TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Gadfly is a cool Twitter/Silverlight app Enable DreamScene in Windows 7 Microsoft’s “How Do I ?” Videos Home Networks – How do they look like & the problems they cause Check Your IMAP Mail Offline In Thunderbird Follow Finder Finds You Twitter Users To Follow

    Read the article

  • Computer can't boot

    - by zETO
    I have a 1 year old PC and the last weeks, when I press the ON button the PC doesn't power on ( Like I didn't press the ON button ). I have to plug and unplug a few times the power cord in order to make it work. At the start this happened once in 10 boots. Now it happens much more frequently to the point that when I press the power on button it never even opens if I don't do the cord switch thingy. Very rarely also, the PC shut downs for no reason and no warning, even when idle. The important fact to note here is, the green light on the motherboard is always on, even when the PC doesn't power on. What should I do? Is it a Power Supply failure or a motherboard? My power supply is a high end corsair model, AX850 and my motherboard a high end ASUS.

    Read the article

  • Laptop accessories for mobile warrior (light power adapter & case/bag)

    - by wonsungi
    Lugging my X301 between work and home, I realized my laptop's accessories weigh more than the laptop itself! I'm ordering a 2nd AC power adapter so I don't even have to carry one at all, but I may as well get the lightest one possible. My X301 came with a pretty svelt 65W power adapter, but can anyone suggest a lighter power adapter or confirm the weights I've found below? mass vol dimensions W Model ---- ------- ----------- --- ------------------- 210g 149cm^3 108x46x30mm 65W Coolermaster [NA 65] 244g 189cm^3 140x75x18mm 65W ThermalTake [ADP65W0001] 260g 130cm^3 104x43x29mm 65W Lenovo (came with X301) 326g 198cm^3 145x76x18mm 95W Coolermaster [SNA 95] 330g 180cm^3 150x60x20mm 90W Kensington USB [K38030US] Apple's 60W power adapter seems much smaller/lighter than the PC products listed above, so I think a better PC power adapter could exist. There are much smaller 45W "netbook" adapters, but are these too weak for my X301? I would not mind if it just meant the battery couldn't charge while the laptop was on, but I am afraid there will be worse consequences. Also, I have decided to swap my Logitech Kinetik briefcase for a Tom Bihn Ristretto. Less protection, but much lighter, less bulky, and easier to carry. Any suggestions for better laptop cases/bags?

    Read the article

  • How to power a serial port under linux?

    - by Lex
    I got a serial to ethernet device connected to a Serial (COM) port on a Linux machine (debian etch), I connected it correctly but it did not power up, I suppose I need to power the device port, anyone knows how to power it under linux? Thankyou in advance.

    Read the article

  • Docking station power adapter is not recognized by my Dell notebook

    - by Soner Gönül
    At this morning, my laptop (Dell Latitude e6410) gave me this error. I didn't do anything, I didn't change anything. And I got this docking station just 2 month ago. I made a little research on the internet but I couldn't find read solution for this situation. Now my docking station is not charging to my laptop. I'm using Windows 7. What should I do in this situation ? Your docking station power adapter is not recognized by your Dell notebook. As a result, your power adapter may not provide sufficient power to run the system, your battery will not charge, your system will run slowly. Please insert a 65 watt Dell approved power adapter.

    Read the article

  • Laptop Power down.

    - by BENBUN
    This question relates to my ACER laptop running Windows VISTA. Currently when I close the lid of my laptop the laptop does not power down, however when I open the lid it does. When looking at the power settings it is set to power down when closing the lid. The trigger to this seems to be the lid being opened not being closed. I seem to recall this behaviour changing when I installed Windows Media centre. Any ideas on how I can get the power down to work on the lid closing. thanks

    Read the article

  • Too much power for 1-2 power outlets in my room?

    - by jasondavis
    I live in the USA, I am curious about plugging in too many computer items into 1 to 2 power plugin outlets. Most power outlets have 2 plugins, some have 4 and more though. Many people will plug in a power strib/bar into 1 of these outlets so that they can plugin even more items. So if I have 2 plugins near my computer, would it be bad to plugin... - My PC - 3-4 monitors - Stereo amp for PC sound - Lamp - External drives - other similar items

    Read the article

  • Too much power for 1-2 power outlets in my room?

    - by jasondavis
    I live in the USA, I am curious about plugging in too many computer items into 1 to 2 power plugin outlets. Most power outlets have 2 plugins, some have 4 and more though. Many people will plug in a power strib/bar into 1 of these outlets so that they can plugin even more items. So if I have 2 plugins near my computer, would it be bad to plugin... - My PC - 3-4 monitors - Stereo amp for PC sound - Lamp - External drives - other similar items

    Read the article

  • Laptop Power down.

    - by BENBUN Coder
    This question relates to my ACER laptop running Windows VISTA. Currently when I close the lid of my laptop the laptop does not power down, however when I open the lid it does. When looking at the power settings it is set to power down when closing the lid. The trigger to this seems to be the lid being opened not being closed. I seem to recall this behaviour changing when I installed Windows Media centre. Any ideas on how I can get the power down to work on the lid closing. thanks

    Read the article

  • Does lighter wallpaper consumes lesser power than a Darker one

    - by Lamb
    My VAIO advised me to switch to a White Background, to reduce power consumption. But it seems contradictory to common logic. Its like saying a brighter Torch consuming less than a dimmer one. Common Logic says that, Screen is BLACK when not using any POWER, so displaying black color should not consume any power (because without powering any pixel it gives black color) Also a white screen gives me more light than a darker one, so it should use more Energy. White Wallpaper = More Light Output = More Electrical Energy Consumed Black Wallpaper = Less Light = Less Electricity Consumed My question is - Is there anything wrong with the above argument ? A Lighter Wallpaper consumes less power than a Darker one. Is it true ? If yes, Why ?

    Read the article

  • Power Supply Not Working?

    - by Mr.Glass
    So I recently made some purchases for a new computer including: Motherboard: Gigabyte GA-EP45-UD3R CPU : Intel Core2Quad 2.66Ghz Power Supply: Antec Basiq 500w UPDATE: I got the Power Supply working, the motherboard's lights come on, the video card fan spins, BUT the CPU fan does NOT spin and there is no video. Whats the possibility of lacking power? In the mobo guide it says the use of a power supply providing a 2x4 12V connector is recommended (I do not have this connector) by the CPU manufacturer when using an Intel Extreme Edition (I'm using Core2Quad) UPDATE: Got it working, intstalling windows 7 now. THANKS GUYS!!

    Read the article

  • power equation for RAM

    - by kashyapa
    How is the dynamic power consumption of memory determined . Can anybody give a canonical equation for power consumption of the RAM. What are the parameters involved in determing the dynamic power consumption of RAM ? Thanks in advance

    Read the article

  • windows 7 monitor instantly resumes from power off

    - by user167328
    It seems that some service or program is preventing my monitor from going into power save mode but I cannot find a way to dig down the cause. Does anybody know a way to find out which event may be causing the problem? Background information: If I leave/lock my computer I want to immediately power off the monitor. Stupid windows has no program for this so I use a third party utility. I use Display.exe from Noel Danjou since 2005 and have had no problem with it on XP, my Notebook with w7 x64 pro and at the office with w7 x64 enterprise. With my new home pc with w7 x64 pro the monitor goes off but instantly comes back on after a second. So I tested using a power plan with the shortest timeout of 1 minute but with that the display never goes off at all. (Setting a power plan timeout is no useful option because then I cannot read a document or watch a movie without the monitor going off) I could try trial and error methods but this is cumbersome and not what I regard as a professional solution. So I would prefer a way to analyze the windows events to find out the reason for the display staying active. Add On: In the meantime I tried safe mode and also exited from all tray programs but the problem is still there. I also checked the BIOS for special power settings but still no solution (P.S. Mobo is H87-G41 PC Mate with latest BIOS rev.)

    Read the article

  • DISK BOOT FAILURE after upgrading power supply

    - by Phenom
    After upgrading my power supply, I get the following error message when trying to boot into Windows 7. DISK BOOT FAILURE, INSERT SYSTEM DISK AND PRESS ENTER My Windows 7 installation is on a SATA hard drive. I'm able to fix this problem if I hook up my IDE hard drive, then it boots the SATA hard drive fine. I don't like this solution though because then that means my IDE hard drive is drawing power even though it isn't being used. Why would a newer power supply need the IDE hard drive hooked up just to boot into the SATA hard drive? There are no boot files on the IDE hard drive; it is completely empty. My old power supply did not need it hooked up in order to boot the SATA hard drive.

    Read the article

  • Hp pavilion dv7 power button

    - by Danny B
    My power button is non responsive I am getting LED for charging. I've taken it apart before to change the dc jack and it was fine and a few months later it just powered off. I try to power back on and is goes to start up then shuts off. I just took it apart and came to find the ribbon cable connecting the power button/speakers cover is barely hanging on do I have to replace the whole thing or is there a way to replace the ribbon cable?

    Read the article

  • I modified my registry and now my laptop doesn't report its battery or power settings

    - by Crouch
    I saved a backup of my registry and then made a change to it. After the change, the Windows 7 battery meter no longer reported how much battery power was left. I also was no longer able to change between Power Profiles in the Control Panel. I tried to restore the original registry but it didn't restore the lost power features. Now I have to keep my laptop plugged in all day because I never know how much power I have left. Anyone know what to do here?

    Read the article

  • Workaround for Dell "Power Supply Not Recognised" issue

    - by Haedrian
    So, I have a Dell Inspirion and the power supply port appears to be damaged. Basically when I plug it in I get a nice popup telling me that it couldn't detect that its a Dell power supply so it won't charge the battery and underclocks the system. It still works for other purposes (that is, giving power) I thought it was the actual power supply cable so I bought a new one, that worked for a while, provided I inserted it at JUST THE RIGHT angle. But now that's not working anymore, so I assume its the part which connects to the computer. The battery charging I can live without, the underclocking I can't. I'd like a way around this issue. Things I've tried: Updating the BIOS Replacing the power supply cable Inserting it at different angles Turning it off and on again Swearing at it Twisting it while inserting it So, is there a workaround somehow? I'd like to avoid taking out my soldering kit and risking permanently damaging expensive equipment if that's allright. I'm hoping for a software solution. Added: The exact model is a Del Inspirion N5010

    Read the article

  • ATX power: 20 or 24 pins?

    - by djechelon
    What is the difference between 20-pins ATX power cables and 24-pins ATX power cables for motherboard? I see that Cooler Master Silent Pro PSU has an extensible plug, showing 20 pins + 4 pluggable pins. Since I'm having troubles with my motherboard, which has 24 pins, I tried to connect only the first 20 and the system booted up fine. I'm curious: can any ATX motherboard run with 20-pins power? Will I simply experience lower performance?

    Read the article

  • MERGE Bug with Filtered Indexes

    - by Paul White
    A MERGE statement can fail, and incorrectly report a unique key violation when: The target table uses a unique filtered index; and No key column of the filtered index is updated; and A column from the filtering condition is updated; and Transient key violations are possible Example Tables Say we have two tables, one that is the target of a MERGE statement, and another that contains updates to be applied to the target.  The target table contains three columns, an integer primary key, a single character alternate key, and a status code column.  A filtered unique index exists on the alternate key, but is only enforced where the status code is ‘a’: CREATE TABLE #Target ( pk integer NOT NULL, ak character(1) NOT NULL, status_code character(1) NOT NULL,   PRIMARY KEY (pk) );   CREATE UNIQUE INDEX uq1 ON #Target (ak) INCLUDE (status_code) WHERE status_code = 'a'; The changes table contains just an integer primary key (to identify the target row to change) and the new status code: CREATE TABLE #Changes ( pk integer NOT NULL, status_code character(1) NOT NULL,   PRIMARY KEY (pk) ); Sample Data The sample data for the example is: INSERT #Target (pk, ak, status_code) VALUES (1, 'A', 'a'), (2, 'B', 'a'), (3, 'C', 'a'), (4, 'A', 'd');   INSERT #Changes (pk, status_code) VALUES (1, 'd'), (4, 'a');          Target                     Changes +-----------------------+    +------------------+ ¦ pk ¦ ak ¦ status_code ¦    ¦ pk ¦ status_code ¦ ¦----+----+-------------¦    ¦----+-------------¦ ¦  1 ¦ A  ¦ a           ¦    ¦  1 ¦ d           ¦ ¦  2 ¦ B  ¦ a           ¦    ¦  4 ¦ a           ¦ ¦  3 ¦ C  ¦ a           ¦    +------------------+ ¦  4 ¦ A  ¦ d           ¦ +-----------------------+ The target table’s alternate key (ak) column is unique, for rows where status_code = ‘a’.  Applying the changes to the target will change row 1 from status ‘a’ to status ‘d’, and row 4 from status ‘d’ to status ‘a’.  The result of applying all the changes will still satisfy the filtered unique index, because the ‘A’ in row 1 will be deleted from the index and the ‘A’ in row 4 will be added. Merge Test One Let’s now execute a MERGE statement to apply the changes: MERGE #Target AS t USING #Changes AS c ON c.pk = t.pk WHEN MATCHED AND c.status_code <> t.status_code THEN UPDATE SET status_code = c.status_code; The MERGE changes the two target rows as expected.  The updated target table now contains: +-----------------------+ ¦ pk ¦ ak ¦ status_code ¦ ¦----+----+-------------¦ ¦  1 ¦ A  ¦ d           ¦ <—changed from ‘a’ ¦  2 ¦ B  ¦ a           ¦ ¦  3 ¦ C  ¦ a           ¦ ¦  4 ¦ A  ¦ a           ¦ <—changed from ‘d’ +-----------------------+ Merge Test Two Now let’s repopulate the changes table to reverse the updates we just performed: TRUNCATE TABLE #Changes;   INSERT #Changes (pk, status_code) VALUES (1, 'a'), (4, 'd'); This will change row 1 back to status ‘a’ and row 4 back to status ‘d’.  As a reminder, the current state of the tables is:          Target                        Changes +-----------------------+    +------------------+ ¦ pk ¦ ak ¦ status_code ¦    ¦ pk ¦ status_code ¦ ¦----+----+-------------¦    ¦----+-------------¦ ¦  1 ¦ A  ¦ d           ¦    ¦  1 ¦ a           ¦ ¦  2 ¦ B  ¦ a           ¦    ¦  4 ¦ d           ¦ ¦  3 ¦ C  ¦ a           ¦    +------------------+ ¦  4 ¦ A  ¦ a           ¦ +-----------------------+ We execute the same MERGE statement: MERGE #Target AS t USING #Changes AS c ON c.pk = t.pk WHEN MATCHED AND c.status_code <> t.status_code THEN UPDATE SET status_code = c.status_code; However this time we receive the following message: Msg 2601, Level 14, State 1, Line 1 Cannot insert duplicate key row in object 'dbo.#Target' with unique index 'uq1'. The duplicate key value is (A). The statement has been terminated. Applying the changes using UPDATE Let’s now rewrite the MERGE to use UPDATE instead: UPDATE t SET status_code = c.status_code FROM #Target AS t JOIN #Changes AS c ON t.pk = c.pk WHERE c.status_code <> t.status_code; This query succeeds where the MERGE failed.  The two rows are updated as expected: +-----------------------+ ¦ pk ¦ ak ¦ status_code ¦ ¦----+----+-------------¦ ¦  1 ¦ A  ¦ a           ¦ <—changed back to ‘a’ ¦  2 ¦ B  ¦ a           ¦ ¦  3 ¦ C  ¦ a           ¦ ¦  4 ¦ A  ¦ d           ¦ <—changed back to ‘d’ +-----------------------+ What went wrong with the MERGE? In this test, the MERGE query execution happens to apply the changes in the order of the ‘pk’ column. In test one, this was not a problem: row 1 is removed from the unique filtered index by changing status_code from ‘a’ to ‘d’ before row 4 is added.  At no point does the table contain two rows where ak = ‘A’ and status_code = ‘a’. In test two, however, the first change was to change row 1 from status ‘d’ to status ‘a’.  This change means there would be two rows in the filtered unique index where ak = ‘A’ (both row 1 and row 4 meet the index filtering criteria ‘status_code = a’). The storage engine does not allow the query processor to violate a unique key (unless IGNORE_DUP_KEY is ON, but that is a different story, and doesn’t apply to MERGE in any case).  This strict rule applies regardless of the fact that if all changes were applied, there would be no unique key violation (row 4 would eventually be changed from ‘a’ to ‘d’, removing it from the filtered unique index, and resolving the key violation). Why it went wrong The query optimizer usually detects when this sort of temporary uniqueness violation could occur, and builds a plan that avoids the issue.  I wrote about this a couple of years ago in my post Beware Sneaky Reads with Unique Indexes (you can read more about the details on pages 495-497 of Microsoft SQL Server 2008 Internals or in Craig Freedman’s blog post on maintaining unique indexes).  To summarize though, the optimizer introduces Split, Filter, Sort, and Collapse operators into the query plan to: Split each row update into delete followed by an inserts Filter out rows that would not change the index (due to the filter on the index, or a non-updating update) Sort the resulting stream by index key, with deletes before inserts Collapse delete/insert pairs on the same index key back into an update The effect of all this is that only net changes are applied to an index (as one or more insert, update, and/or delete operations).  In this case, the net effect is a single update of the filtered unique index: changing the row for ak = ‘A’ from pk = 4 to pk = 1.  In case that is less than 100% clear, let’s look at the operation in test two again:          Target                     Changes                   Result +-----------------------+    +------------------+    +-----------------------+ ¦ pk ¦ ak ¦ status_code ¦    ¦ pk ¦ status_code ¦    ¦ pk ¦ ak ¦ status_code ¦ ¦----+----+-------------¦    ¦----+-------------¦    ¦----+----+-------------¦ ¦  1 ¦ A  ¦ d           ¦    ¦  1 ¦ d           ¦    ¦  1 ¦ A  ¦ a           ¦ ¦  2 ¦ B  ¦ a           ¦    ¦  4 ¦ a           ¦    ¦  2 ¦ B  ¦ a           ¦ ¦  3 ¦ C  ¦ a           ¦    +------------------+    ¦  3 ¦ C  ¦ a           ¦ ¦  4 ¦ A  ¦ a           ¦                            ¦  4 ¦ A  ¦ d           ¦ +-----------------------+                            +-----------------------+ From the filtered index’s point of view (filtered for status_code = ‘a’ and shown in nonclustered index key order) the overall effect of the query is:   Before           After +---------+    +---------+ ¦ pk ¦ ak ¦    ¦ pk ¦ ak ¦ ¦----+----¦    ¦----+----¦ ¦  4 ¦ A  ¦    ¦  1 ¦ A  ¦ ¦  2 ¦ B  ¦    ¦  2 ¦ B  ¦ ¦  3 ¦ C  ¦    ¦  3 ¦ C  ¦ +---------+    +---------+ The single net change there is a change of pk from 4 to 1 for the nonclustered index entry ak = ‘A’.  This is the magic performed by the split, sort, and collapse.  Notice in particular how the original changes to the index key (on the ‘ak’ column) have been transformed into an update of a non-key column (pk is included in the nonclustered index).  By not updating any nonclustered index keys, we are guaranteed to avoid transient key violations. The Execution Plans The estimated MERGE execution plan that produces the incorrect key-violation error looks like this (click to enlarge in a new window): The successful UPDATE execution plan is (click to enlarge in a new window): The MERGE execution plan is a narrow (per-row) update.  The single Clustered Index Merge operator maintains both the clustered index and the filtered nonclustered index.  The UPDATE plan is a wide (per-index) update.  The clustered index is maintained first, then the Split, Filter, Sort, Collapse sequence is applied before the nonclustered index is separately maintained. There is always a wide update plan for any query that modifies the database. The narrow form is a performance optimization where the number of rows is expected to be relatively small, and is not available for all operations.  One of the operations that should disallow a narrow plan is maintaining a unique index where intermediate key violations could occur. Workarounds The MERGE can be made to work (producing a wide update plan with split, sort, and collapse) by: Adding all columns referenced in the filtered index’s WHERE clause to the index key (INCLUDE is not sufficient); or Executing the query with trace flag 8790 set e.g. OPTION (QUERYTRACEON 8790). Undocumented trace flag 8790 forces a wide update plan for any data-changing query (remember that a wide update plan is always possible).  Either change will produce a successfully-executing wide update plan for the MERGE that failed previously. Conclusion The optimizer fails to spot the possibility of transient unique key violations with MERGE under the conditions listed at the start of this post.  It incorrectly chooses a narrow plan for the MERGE, which cannot provide the protection of a split/sort/collapse sequence for the nonclustered index maintenance. The MERGE plan may fail at execution time depending on the order in which rows are processed, and the distribution of data in the database.  Worse, a previously solid MERGE query may suddenly start to fail unpredictably if a filtered unique index is added to the merge target table at any point. Connect bug filed here Tests performed on SQL Server 2012 SP1 CUI (build 11.0.3321) x64 Developer Edition © 2012 Paul White – All Rights Reserved Twitter: @SQL_Kiwi Email: [email protected]

    Read the article

  • DNS Query.log - Multiple query’s for ripe.net

    - by Christopher Wilson
    Currently I run a DNS server (bind9) that handles queries from clients over the internet lately I have noticed hundreds of queries from all different address's that look like this (Server IP removed) client 216.59.33.210#53: query: ripe.net IN ANY +ED (0.0.0.0) client 216.59.33.204#53: query: ripe.net IN ANY +ED (0.0.0.0) client 208.64.127.5#53: query: ripe.net IN ANY +ED (0.0.0.0) client 184.107.255.202#53: query: ripe.net IN ANY +ED (0.0.0.0) client 208.64.127.5#53: query: ripe.net IN ANY +ED (0.0.0.0) client 208.64.127.5#53: query: ripe.net IN ANY +ED (0.0.0.0) client 205.204.65.83#53: query: ripe.net IN ANY +ED (0.0.0.0) client 69.162.110.106#53: query: ripe.net IN ANY +ED (0.0.0.0) client 216.59.33.210#53: query: ripe.net IN ANY +ED (0.0.0.0) client 69.162.110.106#53: query: ripe.net IN ANY +ED (0.0.0.0) client 216.59.33.204#53: query: ripe.net IN ANY +ED (0.0.0.0) client 208.64.127.5#53: query: ripe.net IN ANY +ED (0.0.0.0) Can someone please explain why there are so many clients querying for ripe.net ?

    Read the article

  • SQLAuthority News – Download Whitepaper – Understanding and Controlling Parallel Query Processing in SQL Server

    - by pinaldave
    My recently article SQL SERVER – Reducing CXPACKET Wait Stats for High Transactional Database has received many good comments regarding MAXDOP 1 and MAXDOP 0. I really enjoyed reading the comments as the comments are received from industry leaders and gurus. I was further researching on the subject and I end up on following white paper written by Microsoft. Understanding and Controlling Parallel Query Processing in SQL Server Data warehousing and general reporting applications tend to be CPU intensive because they need to read and process a large number of rows. To facilitate quick data processing for queries that touch a large amount of data, Microsoft SQL Server exploits the power of multiple logical processors to provide parallel query processing operations such as parallel scans. Through extensive testing, we have learned that, for most large queries that are executed in a parallel fashion, SQL Server can deliver linear or nearly linear response time speedup as the number of logical processors increases. However, some queries in high parallelism scenarios perform suboptimally. There are also some parallelism issues that can occur in a multi-user parallel query workload. This white paper describes parallel performance problems you might encounter when you run such queries and workloads, and it explains why these issues occur. In addition, it presents how data warehouse developers can detect these issues, and how they can work around them or mitigate them. To review the document, please download the Understanding and Controlling Parallel Query Processing in SQL Server Word document. Note: Above abstract has been taken from here. The real question is what does the parallel queries has made life of DBA much simpler or is it looked at with potential issue related to degradation of the performance? Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, SQL White Papers, SQLAuthority News, T SQL, Technology

    Read the article

  • SQL SERVER – Quiz and Video – Introduction to Hierarchical Query using a Recursive CTE

    - by pinaldave
    This blog post is inspired from SQL Queries Joes 2 Pros: SQL Query Techniques For Microsoft SQL Server 2008 – SQL Exam Prep Series 70-433 – Volume 2.[Amazon] | [Flipkart] | [Kindle] | [IndiaPlaza] This is follow up blog post of my earlier blog post on the same subject - SQL SERVER – Introduction to Hierarchical Query using a Recursive CTE – A Primer. In the article we discussed various basics terminology of the CTE. The article further covers following important concepts of common table expression. What is a Common Table Expression (CTE) Building a Recursive CTE Identify the Anchor and Recursive Query Add the Anchor and Recursive query to a CTE Add an expression to track hierarchical level Add a self-referencing INNER JOIN statement Above six are the most important concepts related to CTE and SQL Server.  There are many more things one has to learn but without beginners fundamentals one can’t learn the advanced  concepts. Let us have small quiz and check how many of you get the fundamentals right. Quiz 1) You have an employee table with the following data. EmpID FirstName LastName MgrID 1 David Kennson 11 2 Eric Bender 11 3 Lisa Kendall 4 4 David Lonning 11 5 John Marshbank 4 6 James Newton 3 7 Sally Smith NULL You need to write a recursive CTE that shows the EmpID, FirstName, LastName, MgrID, and employee level. The CEO should be listed at Level 1. All people who work for the CEO will be listed at Level 2. All of the people who work for those people will be listed at Level 3. Which CTE code will achieve this result? WITH EmpList AS (SELECT Boss.EmpID, Boss.FName, Boss.LName, Boss.MgrID, 1 AS Lvl FROM Employee AS Boss WHERE Boss.MgrID IS NULL UNION ALL SELECT E.EmpID, E.FirstName, E.LastName, E.MgrID, EmpList.Lvl + 1 FROM Employee AS E INNER JOIN EmpList ON E.MgrID = EmpList.EmpID) SELECT * FROM EmpList WITH EmpListAS (SELECT EmpID, FirstName, LastName, MgrID, 1 as Lvl FROM Employee WHERE MgrID IS NULL UNION ALL SELECT EmpID, FirstName, LastName, MgrID, 2 as Lvl ) SELECT * FROM BossList WITH EmpList AS (SELECT EmpID, FirstName, LastName, MgrID, 1 as Lvl FROM Employee WHERE MgrID is NOT NULL UNION SELECT EmpID, FirstName, LastName, MgrID, BossList.Lvl + 1 FROM Employee INNER JOIN EmpList BossList ON Employee.MgrID = BossList.EmpID) SELECT * FROM EmpList 2) You have a table named Employee. The EmployeeID of each employee’s manager is in the ManagerID column. You need to write a recursive query that produces a list of employees and their manager. The query must also include the employee’s level in the hierarchy. You write the following code segment: WITH EmployeeList (EmployeeID, FullName, ManagerName, Level) AS ( –PICK ANSWER CODE HERE ) SELECT EmployeeID, FullName, ” AS [ManagerID], 1 AS [Level] FROM Employee WHERE ManagerID IS NULL UNION ALL SELECT emp.EmployeeID, emp.FullName mgr.FullName, 1 + 1 AS [Level] FROM Employee emp JOIN Employee mgr ON emp.ManagerID = mgr.EmployeeId SELECT EmployeeID, FullName, ” AS [ManagerID], 1 AS [Level] FROM Employee WHERE ManagerID IS NULL UNION ALL SELECT emp.EmployeeID, emp.FullName, mgr.FullName, mgr.Level + 1 FROM EmployeeList mgr JOIN Employee emp ON emp.ManagerID = mgr.EmployeeId Now make sure that you write down all the answers on the piece of paper. Watch following video and read earlier article over here. If you want to change the answer you still have chance. Solution 1) 1 2) 2 Now compare let us check the answers and compare your answers to following answers. I am very confident you will get them correct. Available at USA: Amazon India: Flipkart | IndiaPlaza Volume: 1, 2, 3, 4, 5 Please leave your feedback in the comment area for the quiz and video. Did you know all the answers of the quiz? Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: Joes 2 Pros, PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >