Search Results

Search found 430 results on 18 pages for 'sas'.

Page 3/18 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • In need of a semantic thesaurus as a SAS

    - by Roy Peleg
    Hello, I'm currently building a web application. In one of it's key processes the application need to match short phrases to other similar ones available in the DB. The application needs to be able to match the phrase: Looking for a second hand car in good shape To other phrases which basically have the same meaning but use different wording, such as: 2nd hand car in great condition needed or searching for a used car in optimal quality The phrases are length limited (say 250 chars), user generated & unstructured. I'm in need of a service / company / some solution which can help / do these connections for me. Can anyone give any ideas? Thanks, Roy

    Read the article

  • Regressing panel data in SAS.

    - by John
    Hey Guys, thanks to your help I succesfully managed all my databases! I am now looking at a panel data set on which I have to regress. Since I only started my Phd this semester together with the econometrics courses I am still new to many statistic applications and regression methods. I want to do a simple regression as in Y = x1 x2 x3 etc, now I already browsed through some literature and found that for panel data it's common to do a fixed effects regression. Also, my Y variable only has positive values so I was thinking in the direction of a Tobit model? I'm doing some research concerning the coverage of analysts in the financial business. My independent variable is the coverage of analysts on a certain firm, so per observation i have 1 analyst and 1 firm, together with different characteristics(market cap and betas etc) of the firm. All this data is monthly. As coverage cannot become negative (only 0) I was thinking of a Tobit model? Do you guys have any ideas what would be a good regression method? Or have some good sources (e books, written books, through university I have access to almost anything concerning my field of work) of information (cause I do have to learn these things for future research)? Thanks!

    Read the article

  • Merging datasets based on 2 variables in SAS.

    - by John
    Hye Guys, my question is the following, i'm working with different databases, all contain information about 1000+ companies, a company is defined by its ticker code (the short version of the name( Ford as F) usually seen on stock quotation boards). Aside from the ticker code to merge on I also have to merge on the time, I used month as a count variable throughout my time series. The final purpose is to have a regression in the kind of Y(jt) = c + X(jt) +X1(jt) etc with j = company (ticker) and t = time (month). So imagine I have 2 databases, one which is the base database with variables such as Tickers, months, beta's of a company (risk measure) etc and a second database which has an extra variable (let's say market capitalisation). What I want to do then is to merge these 2 databases based on the ticker and the month. Example: Base database: Ticker __ Month __ Betas AA __ 4 __ 1.2 BB __ 8 __ 1.18 Second database: Ticker __ Month __ MCAP AA __ 4 __ 8542 BB __ 6 __ 1245 Then after merge I would like to have something like this: Ticker __ Month _ Betas ___ MCAP AA __ 4 _ 1.2 ___ 8542 So all observations that do not match BOTH date and ticker have to be dropped, I'm sure this is possible, just can't find the right type of code. Thanks! PS: I'm guessing the underscars have something to do with font layout but both the bold as italic is supposed to be normal :)

    Read the article

  • Counting variables per observation per month in Sas.

    - by John
    Hey guys, a quick question, I have data of the following sort: Ticker _ Date _ Fem Analyst (dummy 1 if true) AA _ 04/2001 _ 1 AA _ 04/2001 _ 1 AA _ 04/2001 _ 1 AA _ 05/2002 _ 1 AA _ 05/2002 _ 1 AA _ 07/2002 _ 0 AA _ 04/2003 _ 1 and so on.. What I want to receive is the following: Ticker _ Date _ Number of fem analyst AA _ 04/2001 _ 3 AA _ 05/2002 _ 2 AA _ 07/2002 _ 0 AA _ 04/2003 _ 1 So an easy counting algorithm that allows me to count for the number of analysts per company per month (the date is in 01/04/2002 format but I also have a month count variable which can be used too) Any ideas?

    Read the article

  • Can the Intel C600-series SAS controller RAID SATA drives?

    - by CyberShadow
    (Sorry if this is off-topic - technically this is a home workstation setting, but is regarding mostly-server technology.) I have a GA-X79S-UP5-WIFI motherboard and four ST3000DM001 drives, and the IRST manager isn't letting me put the drives in a RAID (it lists them, but the option to select the C600-series controller is simply grayed out). Have I done a mistake? Do I need SAS drives to RAID them on the SAS controller?

    Read the article

  • Les solutions BI de SAS arrivent sur iPad et iPhone, du fait d'un accord avec Mellmo

    Les solutions BI de SAS arrivent sur iPad et iPhone, du fait d'un accord avec Mellmo Les appareils Apple pourraient bien faire une percée en entreprise, aidés par un accord qui vient d'être signé entre SAS et Mellmo. Ce rapprochement va permettre à SAS de mobiliser ces logiciels, et donc de proposer des applications d'analytique sur iPhone et iPad, pour permettre aux professionnels d'obtenir des analyses et des rapports sur des données business en temps réel. En clair, il s'agit de favoriser l'adoption de la BI (Business Intelligence) mobile, un type de services qui n'est pas encore très utilisé. Des craintes en termes de sécurité et de confidentialité des données, mais aussi une difficulté à appréhen...

    Read the article

  • SAS instead of SATA 2 for my hard drives?

    - by jasondavis
    I am building a new system soon, I will have multiple 1-2tb hard drives for storage in it. I only have experience uasing the sataII drives but I saw somewhere that I should be using something like SAS? I read that if I were going to have 20 drives that I could use 4 SAS cables vs 20 SATA cables. Can someone help me understand this better? If it were only 4 cables then how would 20 drives hook up? Also can a regualr sata2 drive hook up to that?

    Read the article

  • SAS on OS X any way to run without working within virtual machine?

    - by user309284
    I would like to edit and submit SAS code from emacs (aquamacs) on OS X to SAS running on Vista (through Parallels). Any idea how to do this? I like to do everything through one place and it is really annoying to work within the windows emulator. I have run SAS from a linux server through aquamacs but wonder if something similar can be done locally. Any ideas?

    Read the article

  • What is a Linux device name for RAID of sas drives?

    - by flashnik
    I have a RAID1 using Promise FastTrack TX2650 consisting of 2 SAS drives. What is a Linux device name for them? Like sda is for first sata drive. I have Windows server so I can't look it directly but need this information for smartctl usage. UPDATE. I found how to access RAID: smartctl -d scsi sdb (because I also have a SATA drive). But in this case I just get an information about just raid controller though I wantto get information about drives itself. Is it possible? Promises's control panel provides information only about their healthy status (boolean) and I want more. Mostly now I need information about temperature.

    Read the article

  • Is it normal for a SAS drive to have a few bad blocks, or should I replace my drive ASAP?

    - by Nate
    I have a drive—part of a RAID 1 mirror—that has two bad blocks. Adaptec Storage Manger e-mailed me when it detected the blocks. It shows 4 medium errors for that drive, but state is still “optimal”. This is my first time using Adaptec RAID controllers. I don’t know if an occasional bad block is normal, or if I should immediately replace that drive. Update: The drive failed later the same day! The disk subsystem is: Adaptec 6405 with ZMM (2) Seagate near-line SAS drives (ST31000424SS) The other drive hasn’t reported any bad blocks yet. I am running a consistency check.

    Read the article

  • Does the Intel DX79TO motherboard support x8 devices (SAS HBAs) on PCIe x16 slots?

    - by Zac B
    Context: I have an Intel DX79TO motherboard and a Sun SAS3081E-S/LSI 1060E-S HBA card with a PCIe x8 interface. I plug the HBA into my mobo next to my graphics card, and the HBA power lights illuminate, but the BIOS and OSes (tried Linux, ESXi, Win7) don't see the HBA at all. Question: Does the DX79TO motherboard support non-x16/non-GPU devices in its PCIe x16 slots? According to this question, some consumer motherboards don't support this, but I can't figure out whether or not this motherboard/family does. The answer will affect whether I buy a new motherboard or RMA the SAS card, with money attached to each course, so I figured I'd ask here first. What I've Tried: I've read the spec/manuals for the motherboard and the HBA, and I didn't see anything regarding whether or not the x16 slots were back-compatible to lower lane widths/non graphics-card devices, or whether or not the card could run in wider slots than x8. I've tried contacting Intel, but that was over a month ago and I haven't yet heard anything back except an automated "we got your email!" message.

    Read the article

  • from Java to SAS

    - by Giovanni Rossi
    I am a seasoned python,java,...other programmer having a (fairly advanced) mathematical education (so I do understand statistics and data mining, for example) . For various reasons I am thinking to switch to SAS/BI area (I am naming SAS because it might be, for me, a possible way to enter in BI). My question, for whoever might have an experience of both: is it, in BI current state, worth it? I mean, the days of big ideas in BI for business seem to be over (there are the APIs, managers think that they know what you can do with them), and my mathematical background might turn out to be superflous. Also, the big companies now have their data organized, have their BI procedures well established, and trying to analyze it from a different standpoint might not be what they want. Another difference is: while in Java etc. development one codes and codes and codes, I don't know if this is the case for BI; in fact, from what I read on the net, a BI (or OLAP, ...etc) developer, in a big organization, is usually in a state of standby, and does in fact little coding. Any opinions, and in particular strong opinions, will be appreciated.

    Read the article

  • How do I encode Unicode strings using pyodbc to save to a SAS dataset?

    - by Chris B.
    I'm using Python to read and write SAS datasets, using pyodbc and the SAS ODBC drivers. I can load the data perfectly well, but when I save the data, using something like: cursor.execute('insert into dataset.test VALUES (?)', u'testing') ... I get a pyodbc.Error: ('HY004', '[HY004] [Microsoft][ODBC Driver Manager] SQL data type out of range (0) (SQLBindParameter)') error. The problem seems to be the fact I'm passing a unicode string; what do I need to do to handle this?

    Read the article

  • Dell External SAS 5/E HBA and Hyper-V

    - by JohnyD
    I have a Dell R710 running Win2008 R2 + Hyper-V with dual SAS 5/E HBA's. I'm building a Linux VM to install Bacula on and I need to connect it to my Dell PowerVault 124T via the SAS HBA. I've been doing some looking online and I have yet to find a straightforward answer on how to connect a SAS HBA to a VM, let alone a Linux VM. The flavor is Ubuntu 32-bit.

    Read the article

  • PostgreSQL server: 10k RPM SAS or Intel 520 Series SSD drives?

    - by Vlad
    We will be expanding the storage for a PostgreSQL server and one of the things we are considering is using SSDs (Intel 520 Series) instead of rotating discs (10k RPM). Price per GB is comparable and we expect improved performance, however we are concerned about longevity since our database usage pattern is quite write-heavy. We are also concerned about data corruption in case of power failure (due to SSDs write cache not flushing properly). We currently use RAID10 with 4 active HDDs (10k 146GB) and 1 spare configured in the controller. It's a HP DL380 G6 server with P410 Smart Array Controller and BBWC. What makes more sense: upgrading the drives to 300GB 10k RPM or using Intel 520 Series SSDs (240GB)?

    Read the article

  • Cheapest way to connect 20-24 Sata II HDDs in a budget storage server?

    - by Joe Hopfgartner
    I need to assemble a high density storage server for as cheap as possible. It's been a while for me and the last systems I integrated didn't even have Sata yet... During my Research I of course stumbled about Nexsan SATA Beast, the BackBlaze storage Pods as well as some ridiculously overpriced HP Proliant or Dell storage solutions. Finally I choose Norco cases as the way to go. My eye is set on the RPC-4020, which is a 4U 19" Rackmount case with 20 Hot Swap 3.5" SATA/SAS Hdd trays (Backplanes included) and room for two 2.5" OS drives as well as a Slim Line CD-Rom. The backplanes connect with a single SATA port for each drive, so there are 20 internal SATA ports to to be connected. They also have redundant power ports which I think is quite nice. The cheapest price I have found is 290$ + 40$ shipping. In europe the cheapest unfortunately is 370€ (500$) + 40 € shipping... A nice alternative would be the RPC-4224 which has SFF-8087 Mini SAS connectors that bundle 4 SATA trays each. But it doesn't seem to be available in Europe (where i am) anywhere. So here comes my problem: What Mainboard/Controller to choose to connect them for as cheap as possible while still having nice data rates? I have to say that the server is intended as a Storage server with 1gps connectivity and the data transfer will be distributed very evenly across all drives. I also don't require any raid functionality. This is all done at application level, I just need JBOD. So for example if I go for the RPC 4020 Model I need to connect 20 Storage + 1 OS + 1 CDROM Sata ports. I searched a bit and stumbled across this very low priced controller: http://www.intel.com/products/server/raid-controllers/SASWT4I/SASWT4I-overview.htm They sell it for 115 € here and the specs say it can control up to 122 hard discs and has 4 Mini SAS connectors. So I would use 4 Mini SAS 36pin - 4 SATA 7pin cables to connect 4 SATA drives to each port and choose a Mainboard taht has 6 SATA on board (for example this one) and hurray, I can connect my 22 SATA devices for as low as about ~ 220 EUR (cpu, ram, psu, case not counted) Question: WOULD THAT WORK? And if not, why? 2nd Question: If I go for the 4220 or 4224 Model, I have internal Mini SAS connectors. Am I right in assuming that the backplane than acts as a "SAS Expander"? And can I just plug these SAS connectors into any SAS port I can find on my controller / mainboard or are there certain requirements? I know that SATA port multipliers only work with controllers that are ready for that. But isn't this expansion already implemented in the SAS standard? I am sorry that this is a very broad question, but I really spent the last week reading up and it seems to be not so clear! Especially all the controlling hardware specifications! 3rd Question: A lot of hardware specs feature "internal channels" and "internal connectors". The connecors are the physical numbers of places where I can plug a cable in. I got that. But are the "internal channels" always the maximum numbers of physical drives that can be used in the end? Or can I enhance this further by Expanders/Fanouts? 4th and last question: What do you think about the setup so far? Do you know any good alternatives? Maby I am completely going the wrong way and some DAS would be way better? Are there any comparable chassis available in europe? Please feel free to say whatever you think is relevant to the subject!

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • How to remove raid 5 array of 5 SAS and use only use one SAS at a time without writing any thing to disc for recovery

    - by murtaza hamid
    I have HP server ML370 g5 with 8 SAS, c drive 1 72 gb raid 0, d drive 2 72 gb raid 0, f drive 5 146 gb raid 5. 2 of 5 sas drive has got bad sectors and raid 5 is showing status failed. now i want to remove all this 5 SAS and put 1 by 1 in any of the bay to make its image for data recovery purpose without writing anything to the drive. how should i proceed. i also want to keep drive c and d intact. also is it possible if i put all this 5 drives in the bay with the same sequense will it recognise the raid 5 array ( i read some where its smart controller..just curious) many thanks in advance.

    Read the article

  • How to use 3T SAS HDDs which aren't supported by Dell PERC 6i

    - by Sunry
    We bought several 3T SAS hard disks want to use with our Dell R710 server. But we found our R710 can't recognize the 3T hd, and then we dig out the raid card is PERC 6i which doesn't support it. Contacted with Dell that H700 and H800 support 3T hd, thought we can buy a H700 , but the SAS cable is not available in the market right now. And it seems very hard for us to change the raid card, also no suitable tools to tease the special screws. So I want to know if any other method to use these 3T hds instead of putting them in the warehouse? Can I low formatting it to 2TB, and plug it into Dell R710 to use? Or a SAS to USB adapter to use it as USB external disk? I just want to use them by Dell R710 even external.

    Read the article

  • LSI SAS 9240-8i on Ubuntu 12.04 Hangs on Modprobe

    - by Francois Stark
    I used the LSI 9240-8i card on a smaller Intel motherboard with no problems in Ubuntu, with ZFS. However, we rebuilt the server to allow for more disks, using the ASROCK X79 Extreme 11 motherboard. It has 7 PCIe slots, and a LSI 2008 on-board. At first I thought the LSI 9240, when plugged in to PCIe, clashed with the on-board LSI 2008. Every time I plugged in the LSI 9240, modprobe would hang. Then I completely disabled the on-board LSI 2008, and the problem persisted. Last night it booted perfectly ONCE - all LSI cards and connected disks visible... However, all subsequent reboots failed. Both LSI cards' bios scans appear and they both see the disks connected to them, but Ubuntu modprobe hangs. Some selected dmesg lines, with both LSI cards enabled: [ 190.752100] megasas: [ 0]waiting for 1 commands to complete [ 195.772071] megasas: [ 5]waiting for 1 commands to complete [ 200.792079] megasas: [10]waiting for 1 commands to complete [ 205.812078] megasas: [15]waiting for 1 commands to complete [ 210.832037] megasas: [20]waiting for 1 commands to complete [ 215.852077] megasas: [25]waiting for 1 commands to complete [ 220.872072] megasas: [30]waiting for 1 commands to complete [ 225.892078] megasas: [35]waiting for 1 commands to complete [ 230.912086] megasas: [40]waiting for 1 commands to complete [ 235.932075] megasas: [45]waiting for 1 commands to complete [ 240.306157] usb 2-1.5: USB disconnect, device number 7 [ 240.952076] megasas: [50]waiting for 1 commands to complete [ 240.960034] INFO: task modprobe:233 blocked for more than 120 seconds. [ 240.960055] "echo 0 > /proc/sys/kernel/hung_task_timeout_secs" disables this message. [ 240.960067] modprobe D ffffffff81806200 0 233 146 0x00000004 [ 240.960075] ffff880806ae3b48 0000000000000086 ffff880806ae3ae8 ffffffff8101adf3 [ 240.960083] ffff880806ae3fd8 ffff880806ae3fd8 ffff880806ae3fd8 0000000000013780 [ 240.960090] ffffffff81c0d020 ffff880806acae00 ffff880806ae3b58 ffff880808961720 [ 240.960096] Call Trace: [ 240.960107] [<ffffffff8101adf3>] ? native_sched_clock+0x13/0x80 [ 240.960116] [<ffffffff816579cf>] schedule+0x3f/0x60 [ 240.960137] [<ffffffffa00093f5>] megasas_issue_blocked_cmd+0x75/0xb0 [megaraid_sas] [ 240.960144] [<ffffffff8108aa50>] ? add_wait_queue+0x60/0x60 [ 240.960154] [<ffffffffa000a6c9>] megasas_get_seq_num+0xd9/0x260 [megaraid_sas] [ 240.960164] [<ffffffffa000ab31>] megasas_start_aen+0x31/0x60 [megaraid_sas] [ 240.960174] [<ffffffffa00136f1>] megasas_probe_one+0x69a/0x81c [megaraid_sas] [ 240.960182] [<ffffffff813345bc>] local_pci_probe+0x5c/0xd0 [ 240.960189] [<ffffffff81335e89>] __pci_device_probe+0xf9/0x100 [ 240.960197] [<ffffffff8130ce6a>] ? kobject_get+0x1a/0x30 [ 240.960205] [<ffffffff81335eca>] pci_device_probe+0x3a/0x60 [ 240.960212] [<ffffffff813f5278>] really_probe+0x68/0x190 [ 240.960217] [<ffffffff813f5505>] driver_probe_device+0x45/0x70 [ 240.960223] [<ffffffff813f55db>] __driver_attach+0xab/0xb0 [ 240.960227] [<ffffffff813f5530>] ? driver_probe_device+0x70/0x70 [ 240.960233] [<ffffffff813f5530>] ? driver_probe_device+0x70/0x70 [ 240.960237] [<ffffffff813f436c>] bus_for_each_dev+0x5c/0x90 [ 240.960243] [<ffffffff813f503e>] driver_attach+0x1e/0x20 [ 240.960248] [<ffffffff813f4c90>] bus_add_driver+0x1a0/0x270 [ 240.960255] [<ffffffffa001e000>] ? 0xffffffffa001dfff [ 240.960260] [<ffffffff813f5b46>] driver_register+0x76/0x140 [ 240.960266] [<ffffffffa001e000>] ? 0xffffffffa001dfff [ 240.960271] [<ffffffff81335b66>] __pci_register_driver+0x56/0xd0 [ 240.960277] [<ffffffffa001e000>] ? 0xffffffffa001dfff [ 240.960286] [<ffffffffa001e09e>] megasas_init+0x9e/0x1000 [megaraid_sas] [ 240.960294] [<ffffffff81002040>] do_one_initcall+0x40/0x180 [ 240.960301] [<ffffffff810a82fe>] sys_init_module+0xbe/0x230 [ 240.960307] [<ffffffff81661ec2>] system_call_fastpath+0x16/0x1b [ 240.960314] INFO: task scsi_scan_7:349 blocked for more than 120 seconds.

    Read the article