  • How to understand the LSI HBA connector specs?

    - by Sandra
    When reading the specifications for the LSi SAS 9206-16e HBA, it says Storage Connectivity; Data Transfer Rates * 16 ports; 6Gb/s SAS 2.1 compliant SAS Bandwidth * Half Duplex 2400MB/s, x4, 6Gb/s SAS lanes Port Configurations * 16 ea, x1 ports (individual drives) * 4 ea, x4 wide ports * 2ea, x8 wide ports Connectors * Four (x4) mini-SAS HD external connectors (SFF8644) So there are 4 physical connectors. Question What is the bandwidth for each of the connectors? I would be temped to say 6Gb/s * 4, but then it mentions the "Port Configurations" and 2ea, 4ea, 16ea, which I don't understand what is. Does this mean, that the 4 physical connectors are not identical?

    Read the article

  • Dell R910 with Integrated PERC H700 Adapter

    - by Alex
    I am in the process of designing an architecture based around a single Dell R910 server running Windows Server 2008 Enterprise. I would like the server to have 8 RAID1 pairs of spinning disks, so I intend to implement: Dell R910 Server Integrated PERC H700 Adapter with 1 SAS expander on each SAS connector (so 8 expanders in total) 7 RAID1 pairs of 143Gb 15K HDD, each paired on one connector using an expander 1 RAID1 pair of 600Gb 10K HDD, paired on the remaining connector using an expander My main concern is not to introduce bottlenecks in this architecture, and I have the following questions. Will the PERC H700 Adapter act as a bottleneck for disk access? Will using SAS expanders for each RAID1 pair cause a bottleneck or would this be as fast as pairing disks directly attached to the SAS connectors? Can I mix the disks, as long as the disks in each RAID1 pair are the same? I assume so. Can anyone recommend any single-to-double SAS Expanders that are known to function well with the H700? Cheers Alex

    Read the article

  • OS8- AK8- The bad news...

    - by Steve Tunstall
    Ok I told you I would give you the bad news of AK8 to go along with all the cool new stuff, so here it is. It's not that bad, really, just things you need to be aware of. First, the 2013.1 code is being called OS8, AK8 and 2013.1 by different people. I mean different people INSIDE Oracle!! It was supposed to be easy, but it never is. So for the rest of this blog entry, I'm calling it AK8. AK8 is not compatible with the 7x10 series. Ever. The 7x10 series is not supported with AK8, and if you try to upgrade one, it will fail at the healthcheck. All 7x20 series, all of them regardless of age, are supported with AK8. Drive trays. Let's talk about drive trays and SAS cards. The older drive trays for the 7x20 series were called the "Riverwalk 2" or "DS2" trays. They were technically the "J4410" series JBODs that Sun used to sell a la carte before we stopped selling JBODs. Don't get me started on that, it still makes me mad. We used these for many years, and you can still buy them right now until December 15th, 2013, when they will no longer be sold. The DS2 tray only came as a 4u, 24 drive shelf. It held 3.5" drives, and you had a choice of 2TB, 3TB, 300GB or 600GB drives. The SAS HBA in the 7x20 series was called a "Thebe" card, with a part # of 7105394. The 7420, for example, came standard with two of these "Thebe" cards for connecting to the disk trays. Two Thebe cards could handle up to 12 trays, so one would add two more cards to go to 24 trays, or have up to six Thebe cards to handle 36 trays. This card was for external SAS only. It did not connect to the internal OS drives or the Readzillas, both of which used the internal SCSI controller of the server. These Riverwalk 2 trays ARE supported with AK8. You can upgrade your older 7420 or 7320, no problem, as-is. The much older Riverwalk 1 trays or J4400 trays are NOT supported by AK8. However, they were only used by the 7x10 series, and we already said that the 7x10 series was not supported. Here's where it gets tricky. Since last January, we have been selling the new style disk trays. We call them the "DE2-24P" and the "DE2-24C" trays. The "C" tray is for capacity drives, which are 3.5" 3TB or 4TB drives. The "P" trays are for performance drives, which are 2.5" 300GB and 900GB drives. These trays are NOT Riverwalk 2 trays, even though the "C" series may kind of look like it. Different manufacturer and different firmware. They are not new. Like I said, we've been selling them with the 7x20 series since last January. They are the only disk trays we will be selling going forward. Of course, AK8 supports them. So what's the problem? The problem is going to be for people who have to mix drive trays. Remember, your older 7x20 series has Thebe SAS2 HBAs. These have 2 SAS ports per card.  The new ZS3-2 and ZS3-4 systems, however, have the new "Thebe2" SAS2 HBAs. These Thebe2 cards have 4 ports per card. This is very cool, as we can now do more SAS channels with less cards. Instead of needing 4 SAS cards to grow to 24 trays like we did with the old Thebe cards, I can now do 24 trays with only 2 Thebe2 cards. This means more IO slots for fun things like Infiniband and 10G. So far, so good, right? These Thebe2 cards work with any disk tray. You can even mix older DS2 trays with the newer DE2 trays in the same system, as long as you have Thebe2 cards. Ah, there's your problem. You don't have Thebe2 cards in your old 7420, do you? Well, I told you the bad news wasn't that bad, right? We can take out your Thebe cards and replace them with Thebe2. You can then plug your older DS2 trays right back in, and also now get newer DE2 trays going forward. However, it's important that the trays are on different SAS channels. You can mix them in the same system, but not on the same channel. Ask your local SC if you need help with the new cable layout. By the way, the new ZS3-2 and ZS3-4 systems also include a new IO card called "Erie" cards. These are for INTERNAL SAS to the OS drives and the Readzillas. So those are now SAS2 instead of SATA like the older models. Yes, the Erie card uses an IO slot, but that's OK, because the Thebe2 cards allow us to use less SAS HBAs to grow the system, right? That's it. Not too much bad news and really not that bad. AK8 does not support the 7x10 series, and you may need new Thebe2 cards in your older systems if you want to add on newer DE2 trays. I think we can all agree that there are worse things out there. Like our Congress.   Next up.... More good news and cool AK8 tricks. Such as virtual NICS. 

    Read the article

  • Using all Ten IO slots on a 7420

    - by user12620172
    So I had the opportunity recently to actually use up all ten slots in a clustered 7420 system. This actually uses 20 slots, or 22 if you count the clusteron card. I thought it was interesting enough to share here. This is at one of my clients here in southern California. You can see the picture below. We have four SAS HBAs instead of the usual two. This is becuase we wanted to split up the back-end taffic for different workloads. We have a set of disk trays coming from two SAS cards for nothing but Exadata backups. Then, we have a different set of disk trays coming off of the other two SAS cards for non-Exadata workloads, such as regular user file storage. We have 2 Infiniband cards which allow us to do a full mesh directly into the back of the nearby, production Exadata, specifically for fast backups and restores over IB. You can see a 3rd IB card here, which is going to be connected to a non-production Exadata for slower backups and restores from it.The 10Gig card is for client connectivity, allowing other, non-Exadata Oracle databases to make use of the many snapshots and clones that can now be created using the RMAN copies from the original production database coming off the Exadata. This allows for a good number of test and development Oracle databases to use these clones without effecting performance of the Exadata at all.We also have a couple FC HBAs, both for NDMP backups to an Oracle/StorageTek tape library and also for FC clients to come in and use some storage on the 7420.  Now, if you are adding more cards to your 7420, be aware of which cards you can place in which slots. See the bottom graphic just below the photo.  Note that the slots are numbered 0-4 for the first 5 cards, then the "C" slots which is the dedicated Cluster card (called the Clustron), and then another 5 slots numbered 5-9. Some rules for the slots: Slots 1 & 8 are automatically populated with the two default SAS cards. The only other slots you can add SAS cards to are 2 & 7. Slots 0 and 9 can only hold FC cards. Nothing else. So if you have four SAS cards, you are now down to only four more slots for your 10Gig and IB cards. Be sure not to waste one of these slots on a FC card, which can go into 0 or 9, instead.  If at all possible, slots should be populated in this order: 9, 0, 7, 2, 6, 3, 5, 4

    Read the article

  • how to initialize two logical drives on a HP P400i controller without reboot

    - by John
    What I am trying to do is initialize two logical drives on a HP P400i embedded controller without a reboot of the system here my current Array config: array A (SAS, Unused Space: 0 MB) logicaldrive 1 (17.9 GB, RAID 5, OK) logicaldrive 2 (17.9 GB, RAID 5, OK) logicaldrive 3 (75.9 GB, RAID 5, OK) logicaldrive 4 (25.0 GB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 72 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 5 (99 MB, RAID 0, OK) logicaldrive 6 (68.2 GB, RAID 0, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 72 GB, OK) windows 2003 machine running the HpCISs2.sys driver version 6.20.0.32 . I have the ACU and ACU CLI tools installed version 8.28.13.0, P400i firmware version 2.74 . Now what I'd like to do is removes the physical drive 1I:1:4 and delete the two logical drives in array B. then insert a new drive in to bay 4 that contains two new logical drives and have them show up in array B again. So far after I remove the drive and delete the failed logical drives, I insert the new drive and run HPacucli rescan. I get the new drive to show up as unassinged physical drive but I cant figure out now to "for lack of a better word" mount the 2 logical drives on the new unassinged disk. If I reboot the system the array controller picks up the new fourth drive and creates Array B with the drives without problem but I'd really like to not have to reboot the server. Any ideas?

    Read the article

  • LSI RAID-on-chip with RAID6 over two SAS links goes red when HDD enclosure is powered cycled; how to recover?

    - by GregC
    I have a RAID6 array managed by LSI 9286-8e card. I also have Sans Digital 24-bay NexentaSTOR JBOD enclosure with SAS extender built-in. They are connected to separate UPS devices. Normally, I'd shut down the PC, leaving RAID6 in healthy state. But today the power to JBOD enclosure was cut but PC kept running. After restarting the PC, all disks in RAID6 have lit up RED, and the only option in LSI MegaRAID manager app was to reset each disk to unassigned, thereby loosing all data on RAID6 array. Thankfully, I am only testing, but how would I recover if this were to happen in production?

    Read the article

  • How to begin writing an Application Server over Apache?

    - by Cracker
    For my college project, I want to create a simple application server in C that runs over Apache. Like .php, .asp, .jsp, the extension of my files would be .sas. I have already written a parser which reads the .sas files and generates the output. For example, consider a file index.sas with the below code: <% echo "Hello"; %> Now, if I execute: sas index.sas The result would be: Hello Now I want to use this program as an application server over Apache just as PHP, Tomcat, etc. work over Apache. I have heard of cgi-bin but I think PHP uses a different approach. I want to learn the approach which PHP uses. Please advice.

    Read the article

  • Ubuntu doesn't detect drives conected to LSI "Host Bus Adapter"

    - by dvrecmfo
    I purchased LSI SAS 9300-4i Host Bus Adapter, from card bios I can see that it detected all hard drives connected to it, but from ubuntu I can't see them. What I've tried: Installed the driver provided here http://www.lsi.com/products/host-bus-adapters/pages/lsi-sas-9300-4i.aspx#tab/tab3 (I tried both LINUX_RH_SL_OEL_CTX_MPT_GEN3_C0_Phase2.0-3.00.00.00-1 and Linux_Driver_RHEL5-6_SLES10-11_P1) lspci | grep -i lsi 07:00.0 Serial Attached SCSI controller: LSI Logic / Symbios Logic SAS3004 PCI-Express Fusion-MPT SAS-3 (rev 02)

    Read the article

  • Is it possible to shrink the size of an HP Smart Array logical drive?

    - by ewwhite
    I know extension is quite possible using the hpacucli utility, but is there an easy way to reduce the size of an existing logical drive (not array)? The controller is a P410i in a ProLiant DL360 G6 server. I'd like to reduce logicaldrive 1 from 72GB to 40GB. => ctrl all show config detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438006FD9A50 Cache Serial Number: PAAVP9VYFB8Y RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev C Firmware Version: 3.66 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Enabled Total Cache Size: 512 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 412476 MB Status: OK Logical Drive: 1 Size: 72.0 GB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 18504 Strip Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001C132E4BBDFAA6DAD13DA3 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 196 MB, / 12.0 GB, /usr 8.0 GB, /var 4.0 GB, /tmp 2.0 GB OS Status: LOCKED Logical Drive Label: AE438D6A5001438006FD9A50BE0A Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 Device Number: 250 Firmware Version: RevC WWID: 5001438006FD9A5F Vendor ID: PMCSIERA Model: SRC 8x6G

    Read the article

  • Does a 3ware "ECC-ERROR" matter on a JBOD when I have ZFS?

    - by Stefan Lasiewski
    I have a FreeBSD 8.x machine running ZFS and with a 3ware 9690SA controller. The 3ware controller shows an ECC-ERROR with one of the disks: //host> /c0 show VPort Status Unit Size Type Phy Encl-Slot Model ------------------------------------------------------------------------------ p0 OK u0 279.39 GB SAS 0 - SEAGATE ST3300657SS p1 OK u0 279.39 GB SAS 1 - SEAGATE ST3300657SS p2 OK u1 931.51 GB SAS 2 - SEAGATE ST31000640SS p3 ECC-ERROR u2 931.51 GB SAS 3 - SEAGATE ST31000640SS p4 OK u3 931.51 GB SAS 4 - SEAGATE ST31000640SS /c0 show events shows no ECC errors in it's recent history. ZFS does not currently detect any errors. zpool status says No known data errors My question: Is this ECC-ERROR something that I need to be concerned about? According to the 3ware CLI 9.5.2 Manual, an ECC-ERROR means that the 3ware controller caught a read-error for one or more sectors on this drive. This sometimes occurs when a RAID array is recovering from a failed disk. I believe that ECC-ERRORS can also be detected when the 3ware Controller verifies each disk. None of the drives have failed and thus there was no drive rebuild, so I assume that 3ware discovered a bad sector when it ran it's weekly auto-verify scan of the disks. Is this a safe assumption? According to our logs, ZFS has not detected any bad sectors on this drive. ZFS can work around read errors -- if ZFS detects a bad sector on the drive, it will simply mark that sector as bad and never use it again. From the ZFS perspective one bad sector isn't a big deal, although it might indicate that the drive is starting to go bad.

    Read the article

  • HP Proliant DL360 G5 + MSA50 RAID Setup recommendations

    - by JohnRB
    I am running a HP Proliant DL360 2 x 3GHz Xeon 16GB Ram P400 integrated RAID card with 6 x 73GB SAS HDDs running Ubuntu Server 14.04 CLI only. I recently got my hands on a MSA50 SAS Enclosure (10 x SAS HDD bays w/ SAS in/out interface) and wondering what you guys recommended as far as an addon raid controller for one of the pciex slots. I have both slots free Full and Half sizes. Any suggestions are greatly appreciated, I am an I.T. Consultant but have not used these particular units before so I was hoping to hear from someone who has. Thanks!

    Read the article

  • some questions about raid card

    - by cpps
    I have some questions about raid card. Use LSI MegaRAID® SAS 9260-8i raid card as a example. There is only two connection ports on the raid card, and they provide two cables that can connect 8 SAS/SATA storages. The document say it can connect "Maximum 32 drives per controller", I want to know how can I connect more than 8 hard disks with this card. Is that they say "Eight internal SATA+SAS ports" means they provide two cables which can connect 8 hard drives, but you can use other way to connect Maximum 32 drives? The other question. I see host bus adapter has raid integrated , so what is the difference between host bus adapter and raid card. Are they the same? I also know is SAS/SATA Expander's function only to connect more hard drives? Thanks in advance.

    Read the article

  • Why is there an extra HDD under /dev being added in my Linux Kernel?

    - by user1279156
    I have created a Linux kernel and for some reason an extra drive is always added at bootup. My hard drive is listed as /dev/sdb. /dev/sda is created too, and it is 8 MB in size. I can't find anything in the kernel config that is creating this, but if I use a different kernel it is not there. Kernel logs show it as an attached SCSI device, looks just like my hard drive but only 8 MB, and has no partition table. It also doesn't appear to be a physical device. I've tried the kernel on many different models of PCs and it is always there. Does anyone know how to remove it? /dev/disk/by-id gives me: scsi-1AMCC_U21413034D98EB000584 scsi-1AMCC_U21413034D98EB000584-part1 scsi-353333330000007d0 scsi-SATA_ST3250312AS_5VY7SH42 scsi-SATA_WDC_WD800JD-60L_WD-WMAM9Y085675 scsi-SATA_WDC_WD800JD-60L_WD-WMAM9Y085675-part1 scsi-SATA_WDC_WD800JD-60L_WD-WMAM9Y085675-part2 hdparm -i /dev/sda gives me an "invalid argument". dd if=/dev/sda of=sda.img the resulting file does not have any content sdparm results: /dev/sda: Linux scsi_debug 0004 Device identification VPD page: Addressed logical unit: designator type: T10 vendor identification, code set: ASCII vendor id: Linux vendor specific: scsi_debug 2000 designator type: NAA, code set: Binary 0x53333330000007d0 Target port: designator type: Relative target port, code set: Binary transport: Serial Attached SCSI (SAS) Relative target port: 0x1 designator type: NAA, code set: Binary transport: Serial Attached SCSI (SAS) 0x52222220000007ce designator type: Target port group, code set: Binary transport: Serial Attached SCSI (SAS) Target port group: 0x100 Target device that contains addressed lu: designator type: NAA, code set: Binary transport: Serial Attached SCSI (SAS) 0x52222220000007cd designator type: SCSI name string, code set: UTF-8 transport: Serial Attached SCSI (SAS) SCSI name string: naa.52222220000007CD

    Read the article

  • Why has there been no serious research in statistical programming languages for 25 years?

    - by Robert
    The two main statistical languages today are S (in the form of R) and SAS, which today pretty much have the form they had 25 years ago. Whatever usability problems or worker productivity problems they had then, they still have today. I'm a data language designer, and I look at, largely, four aspects: Usability (learning curve & readability - here Python scores high) Productivity (how long it takes to finish your work) Flexibility (SAS and R don't have problems here, but a macro library will) Reliability (in the QA/reproducibility sense, usually a PL does better than a GUI here) By the way, I have a language that can produce complex statistical tables much faster than SAS (like 25 lines of code instead of several hundred lines of code). And I'm going to produce a language for data cleaning that will be great for usability (it'll be my third).

    Read the article

  • mysql: can't set max_allowed_package to anything grater than 16MB

    - by sas
    I'm not sure if this is the right place to post these kind of questions, if it's not so, please (politely) let me know... :-) I need to save files greater than 16MB on a mysql database from a php site... I've already changed the c:\xampp\mysql\bin\my.cnf and set max_allowed_packet to 16 MB, and everything worked fine then I set it to 32 MB but there´s no way I can handle a file bigger than 16 MB I get the following error: 'MySQL server has gone away' (the same error I had when max_allowed_packet was set to 1MB) there must be some other setting that doesn´t allow me to handle files bigger than 16MB maybe the php client, I guess, but I don't know where to edit it this is the code I'm running when file.txt is smaller than 16.776.192 bytes long, it works fine, but if file.txt has 16.777.216 bytes i get the aforementioned error oh, and the field download.content is a longblob... $file = 'file.txt'; $file_handle = fopen( $file, 'r' ); $content = fread( $file_handle, filesize( $file ) ); fclose( $file_handle ); db_execute( 'truncate table download', true ); $sql = "insert into download( code, title, name, description, original_name, mime_type, size, content, user_insert_id, date_insert, user_update_id, date_update ) values ( 'new file', 'new file', 'sas.jpg', 'new file', '$file', 'mime', " . filesize( $file ) . ", '" . addslashes( $content ) . "', 0, " . db_char_to_sql( now_char(), 'datetime' ) . ", 0, " . db_char_to_sql( now_char(), 'datetime' ) . " )"; db_execute( $sql, true ); (the db_execute funcion just opens the connections and executes the sql stuff) running on windows XP sp2 server version: 5.0.67-community PHP Version 4.4.9 mysql client API version: 3.23.49 using: ApacheFriends XAMPP (Basispaket) version 1.6.8 that comes with + Apache 2.2.9 + MySQL 5.0.67 (Community Server) + PHP 5.2.6 + PHP 4.4.9 + PEAR + phpMyAdmin 2.11.9.2 ... this is part of the content of c:\xampp\mysql\bin\my.cnf # The MySQL server [mysqld] port= 3306 socket= "C:/xampp/mysql/mysql.sock" basedir="C:/xampp/mysql" tmpdir="C:/xampp/tmp" datadir="C:/xampp/mysql/data" skip-locking key_buffer = 16M # max_allowed_packet = 1M max_allowed_packet = 32M table_cache = 128 sort_buffer_size = 512K net_buffer_length = 8K read_buffer_size = 256K read_rnd_buffer_size = 512K myisam_sort_buffer_size = 8M

    Read the article

  • Slow disk transfer rate

    - by Nooklez
    I have problem with slow disk transfer rate. It's static files server for our website. I was making backup of data and noticed that tar is very slow. So I did hdparm -t and... hdparm -t /dev/sda3 /dev/sda3: Timing buffered disk reads: 6 MB in 4.70 seconds = 1.28 MB/sec It's low traffic hour now on our site, so huge I/O traffic is not a reason (iotop show less than 1 MB/s). It's RAID10 setup (2x2 SATA drives). Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy ------------------------------------------------------------------------------ u0 RAID-10 OK - - 64K 1396.96 W ON VPort Status Unit Size Type Phy Encl-Slot Model ------------------------------------------------------------------------------ p0 OK u0 698.63 GB SATA 0 - WDC WD7500AADS-00M2 p1 OK u0 698.63 GB SATA 1 - WDC WD7500AADS-00M2 p2 OK u0 698.63 GB SATA 2 - WDC WD7500AADS-00M2 p3 OK u0 698.63 GB SATA 3 - WDC WD7500AADS-00M2 We have recently changed almost all components of server (excluding 3ware controller + disks). And I think problems started since then. Can it be configuration problem or hardware? EDIT: I found something like that in dmesg [166843.625843] irq 16: nobody cared (try booting with the "irqpoll" option) [166843.625846] Pid: 0, comm: swapper Not tainted 3.1.5-gentoo #3 [166843.625847] Call Trace: [166843.625848] <IRQ> [<ffffffff810859d5>] __report_bad_irq+0x35/0xc1 [166843.625856] [<ffffffff81085cec>] note_interrupt+0x165/0x1e1 [166843.625859] [<ffffffff8108445f>] handle_irq_event_percpu+0x16f/0x187 [166843.625861] [<ffffffff810844a9>] handle_irq_event+0x32/0x51 [166843.625863] [<ffffffff8108640b>] handle_fasteoi_irq+0x75/0x99 [166843.625866] [<ffffffff810039d7>] handle_irq+0x83/0x8b [166843.625868] [<ffffffff810036ad>] do_IRQ+0x48/0xa0 [166843.625871] [<ffffffff8155082b>] common_interrupt+0x6b/0x6b [166843.625872] <EOI> [<ffffffff812981e8>] ? acpi_safe_halt+0x22/0x35 [166843.625877] [<ffffffff812981e2>] ? acpi_safe_halt+0x1c/0x35 [166843.625879] [<ffffffff81298216>] acpi_idle_do_entry+0x1b/0x2b [166843.625881] [<ffffffff81298276>] acpi_idle_enter_c1+0x50/0x99 [166843.625884] [<ffffffff813b792a>] cpuidle_idle_call+0xed/0x171 [166843.625886] [<ffffffff81001257>] cpu_idle+0x55/0x81 [166843.625888] [<ffffffff81532a69>] rest_init+0x6d/0x6f [166843.625891] [<ffffffff81aa1aca>] start_kernel+0x329/0x334 [166843.625893] [<ffffffff81aa12a6>] x86_64_start_reservations+0xb6/0xba [166843.625894] [<ffffffff81aa139c>] x86_64_start_kernel+0xf2/0xf9 [166843.625896] handlers: [166843.625898] [<ffffffff812dc8de>] twl_interrupt [166843.625900] Disabling IRQ #16 It's related to problem? EDIT #2: Based on feedback in comments, here is more informations. cat /proc/interrupts 16: 390813 0 0 0 IO-APIC-fasteoi 3w-sas Controller model: [ 1.095350] 3ware Storage Controller device driver for Linux v1.26.02.003. [ 1.095467] 3ware 9000 Storage Controller device driver for Linux v2.26.02.014. [ 1.095641] LSI 3ware SAS/SATA-RAID Controller device driver for Linux v3.26.02.000. [ 1.095787] 3w-sas 0000:01:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 1.095881] 3w-sas 0000:01:00.0: setting latency timer to 64 [ 1.910801] 3w-sas: scsi0: Found an LSI 3ware 9750-4i Controller at 0xfe560000, IRQ: 16. [ 2.216537] 3w-sas: scsi0: Firmware FH9X 5.08.00.008, BIOS BE9X 5.07.00.011, Phys: 8. [ 2.216836] scsi 0:0:0:0: Direct-Access LSI 9750-4i DISK 5.08 PQ: 0 ANSI: 5 And motherboard: description: Motherboard product: P8H67-M vendor: ASUSTeK Computer INC.

    Read the article

  • How to reliably map vSphere disks <-> Linux devices

    - by brianmcgee
    Task at hand After a virtual disk has been added to a Linux VM on vSphere 5, we need to identify the disks in order to automate the LVM storage provision. The virtual disks may reside on different datastores (e.g. sas or flash) and although they may be of the same size, their speed may vary. So I need a method to map the vSphere disks to Linux devices. Ideas Through the vSphere API, I am able to get the device info: Data Object Type: VirtualDiskFlatVer2BackingInfo Parent Managed Object ID: vm-230 Property Path: config.hardware.device[2000].backing Properties Name Type Value ChangeId string Unset contentId string "d58ec8c12486ea55c6f6d913642e1801" datastore ManagedObjectReference:Datastore datastore-216 (W5-CFAS012-Hybrid-CL20-004) deltaDiskFormat string "redoLogFormat" deltaGrainSize int Unset digestEnabled boolean false diskMode string "persistent" dynamicProperty DynamicProperty[] Unset dynamicType string Unset eagerlyScrub boolean Unset fileName string "[W5-CFAS012-Hybrid-CL20-004] l****9-000001.vmdk" parent VirtualDiskFlatVer2BackingInfo parent split boolean false thinProvisioned boolean false uuid string "6000C295-ab45-704e-9497-b25d2ba8dc00" writeThrough boolean false And on Linux I may read the uuid strings: [root@lx***** ~]# lsscsi -t [1:0:0:0] cd/dvd ata: /dev/sr0 [2:0:0:0] disk sas:0x5000c295ab45704e /dev/sda [3:0:0:0] disk sas:0x5000c2932dfa693f /dev/sdb [3:0:1:0] disk sas:0x5000c29dcd64314a /dev/sdc As you can see, the uuid string of disk /dev/sda looks somehow familiar to the string that is visible in the VMware API. Only the first hex digit is different (5 vs. 6) and it is only present to the third hyphen. So this looks promising... Alternative idea Select disks by controller. But is it reliable that the ascending SCSI Id also matches the next vSphere virtual disk? What happens if I add another DVD-ROM drive / USB Thumb drive? This will probably introduce new SCSI devices in between. Thats the cause why I think I will discard this idea. Questions Does someone know an easier method to map vSphere disks and Linux devices? Can someone explain the differences in the uuid strings? (I think this has something to do with SAS adressing initiator and target... WWN like...) May I reliably map devices by using those uuid strings? How about SCSI virtual disks? There is no uuid visible then... This task seems to be so obvious. Why doesn't Vmware think about this and simply add a way to query the disk mapping via Vmware Tools?

    Read the article

  • ZFS - Impact of L2ARC cache device failure (Nexenta)

    - by ewwhite
    I have an HP ProLiant DL380 G7 server running as a NexentaStor storage unit. The server has 36GB RAM, 2 LSI 9211-8i SAS controllers (no SAS expanders), 2 SAS system drives, 12 SAS data drives, a hot-spare disk, an Intel X25-M L2ARC cache and a DDRdrive PCI ZIL accelerator. This system serves NFS to multiple VMWare hosts. I also have about 90-100GB of deduplicated data on the array. I've had two incidents where performance tanked suddenly, leaving the VM guests and Nexenta SSH/Web consoles inaccessible and requiring a full reboot of the array to restore functionality. In both cases, it was the Intel X-25M L2ARC SSD that failed or was "offlined". NexentaStor failed to alert me on the cache failure, however the general ZFS FMA alert was visible on the (unresponsive) console screen. The zpool status output showed: pool: vol1 state: ONLINE scan: scrub repaired 0 in 0h57m with 0 errors on Sat May 21 05:57:27 2011 config: NAME STATE READ WRITE CKSUM vol1 ONLINE 0 0 0 mirror-0 ONLINE 0 0 0 c8t5000C50031B94409d0 ONLINE 0 0 0 c9t5000C50031BBFE25d0 ONLINE 0 0 0 mirror-1 ONLINE 0 0 0 c10t5000C50031D158FDd0 ONLINE 0 0 0 c11t5000C5002C823045d0 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 c12t5000C50031D91AD1d0 ONLINE 0 0 0 c2t5000C50031D911B9d0 ONLINE 0 0 0 mirror-3 ONLINE 0 0 0 c13t5000C50031BC293Dd0 ONLINE 0 0 0 c14t5000C50031BD208Dd0 ONLINE 0 0 0 mirror-4 ONLINE 0 0 0 c15t5000C50031BBF6F5d0 ONLINE 0 0 0 c16t5000C50031D8CFADd0 ONLINE 0 0 0 mirror-5 ONLINE 0 0 0 c17t5000C50031BC0E01d0 ONLINE 0 0 0 c18t5000C5002C7CCE41d0 ONLINE 0 0 0 logs c19t0d0 ONLINE 0 0 0 cache c6t5001517959467B45d0 FAULTED 2 542 0 too many errors spares c7t5000C50031CB43D9d0 AVAIL errors: No known data errors This did not trigger any alerts from within Nexenta. I was under the impression that an L2ARC failure would not impact the system. But in this case, it surely was the culprit. I've never seen any recommendations to RAID L2ARC. Removing the bad SSD entirely from the server got me back running, but I'm concerned about the impact of the device failure (and maybe the lack of notification from NexentaStor as well). Edit - What's the current best-choice SSD for L2ARC cache applications these days?

    Read the article

  • Finding out why Dell Controler is Degraded

    - by Kyle Brandt
    I installed open manage on a couple of my PE 2950s for snmp monitoring of the RAID. All the checks seem to come back okay except for controllerState: [root@aMachine ~]# snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m +StorageManagement-MIB controllerstate StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) Other checks seems to indicate the battery, LD, and physicals disks are all good unless I missing something. Can anyone tell if I am missing something or neglecting something import in my RAID monitoring/understanding? I get degraded for both these servers I have set up. A walk of the entire storage management tree for on of them: StorageManagement-MIB::softwareVersion.0 = STRING: "3.2.0" StorageManagement-MIB::globalStatus.0 = INTEGER: warning(2) StorageManagement-MIB::softwareManufacturer.0 = STRING: "Dell Inc." StorageManagement-MIB::softwareProduct.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::softwareDescription.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::displayName.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::description.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::agentVendor.0 = STRING: "Dell Inc." StorageManagement-MIB::agentTimeStamp.0 = INTEGER: 1273842310 StorageManagement-MIB::agentGetTimeout.0 = INTEGER: 5 StorageManagement-MIB::agentModifiers.0 = INTEGER: 0 StorageManagement-MIB::agentRefreshRate.0 = INTEGER: 300 StorageManagement-MIB::agentMibVersion.0 = STRING: "3.2" StorageManagement-MIB::agentManagementSoftwareURLName.0 = "" StorageManagement-MIB::agentGlobalSystemStatus.0 = INTEGER: nonCritical(4) StorageManagement-MIB::agentLastGlobalSystemStatus.0 = INTEGER: ok(3) StorageManagement-MIB::agentSmartThermalShutdown.0 = INTEGER: notApplicable(3) StorageManagement-MIB::controllerNumber.1 = INTEGER: 1 StorageManagement-MIB::controllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::controllerVendor.1 = STRING: "DELL" StorageManagement-MIB::controllerType.1 = INTEGER: sas(6) StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) StorageManagement-MIB::controllerRebuildRateInPercent.1 = INTEGER: 30 StorageManagement-MIB::controllerFWVersion.1 = STRING: "5.0.2-0003" StorageManagement-MIB::controllerCacheSizeInMB.1 = INTEGER: 256 StorageManagement-MIB::controllerCacheSizeInBytes.1 = INTEGER: 0 StorageManagement-MIB::controllerPhysicalDeviceCount.1 = INTEGER: 5 StorageManagement-MIB::controllerLogicalDeviceCount.1 = INTEGER: 1 StorageManagement-MIB::controllerRollUpStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerComponentStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerNexusID.1 = STRING: "\\0" StorageManagement-MIB::controllerAlarmState.1 = INTEGER: disabled(2) StorageManagement-MIB::controllerDriverVersion.1 = STRING: "00.00.03.05 " StorageManagement-MIB::controllerPCISlot.1 = STRING: "embedded" StorageManagement-MIB::controllerClusterMode.1 = INTEGER: notApplicable(99) StorageManagement-MIB::controllerMinFWVersion.1 = STRING: "5.2.1-0067" StorageManagement-MIB::controllerMinDriverVersion.1 = STRING: "00.00.03.21" StorageManagement-MIB::controllerChannelCount.1 = INTEGER: 2 StorageManagement-MIB::controllerReconstructRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadRate.1 = INTEGER: 30 StorageManagement-MIB::controllerBGIRate.1 = INTEGER: 30 StorageManagement-MIB::controllerCheckConsistencyRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadMode.1 = INTEGER: automatic(1) StorageManagement-MIB::controllerPatrolReadState.1 = INTEGER: stopped(1) StorageManagement-MIB::controllerPatrolReadIterations.1 = INTEGER: 162 StorageManagement-MIB::controllerEntry.57.1 = INTEGER: 99 StorageManagement-MIB::controllerEntry.58.1 = INTEGER: 99 StorageManagement-MIB::channelNumber.1 = INTEGER: 1 StorageManagement-MIB::channelNumber.2 = INTEGER: 2 StorageManagement-MIB::channelName.1 = STRING: "Connector 0" StorageManagement-MIB::channelName.2 = STRING: "Connector 1" StorageManagement-MIB::channelState.1 = INTEGER: ready(1) StorageManagement-MIB::channelState.2 = INTEGER: ready(1) StorageManagement-MIB::channelRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::channelNexusID.2 = STRING: "\\0\\1" StorageManagement-MIB::channelBusType.1 = INTEGER: sas(8) StorageManagement-MIB::channelBusType.2 = INTEGER: sas(8) StorageManagement-MIB::enclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::enclosureName.1 = STRING: "Backplane" StorageManagement-MIB::enclosureVendor.1 = STRING: "DELL" StorageManagement-MIB::enclosureState.1 = INTEGER: ready(1) StorageManagement-MIB::enclosureProductID.1 = STRING: "BACKPLANE " StorageManagement-MIB::enclosureType.1 = INTEGER: internal(1) StorageManagement-MIB::enclosureChannelNumber.1 = INTEGER: 0 StorageManagement-MIB::enclosureRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureNexusID.1 = STRING: "\\0\\0\\0" StorageManagement-MIB::enclosureFirmwareVersion.1 = STRING: "1.00" StorageManagement-MIB::enclosureSASAddress.1 = STRING: "50019090B4C67200" StorageManagement-MIB::arrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskVendor.1 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.2 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.3 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL " StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3) StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 " StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS " StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V " StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 " StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106" StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0" StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2 StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3 StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0" StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1" StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2" StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3" StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 " StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 " StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 " StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 " StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201" StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89" StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9" StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1" StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1) StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005" StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1 StorageManagement-MIB::batteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryVendor.1 = STRING: "DELL" StorageManagement-MIB::batteryState.1 = INTEGER: ready(1) StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2) StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21 StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16) StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0 StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168 StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda" StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1) StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784 StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3) StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5) StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99) StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10) StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536 StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1) StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2 StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1

    Read the article

  • How does Linux determine the SCSI address of a disk?

    - by Chris Sears
    Greetings, I'm working with RHEL 5.5 guest VMs under VMware ESX 4. When I configure the virtual disks in the VM hardware settings, each disk has a SCSI address in the format "N:M". For example, "1:3" would mean SCSI host number 1 and SCSI target ID 3. When I look at the disk info from the VM's BIOS or a Windows OS, the detected SCSI address info matches up with the virtual hardware settings. But under Linux, the SCSI address components don't match up, at least not completely or consistently. I've tried the three supported virtual SCSI and SAS drivers and they all seem to be "broken", but in different ways. Here's a list of the virtual hardware addresses vs what was detected under Linux with each of the drivers: Driver vHW Addr Linux Addr -------- -------- ---------- LSI SAS 0:0 0:0 LSI SAS 0:3 0:1 LSI SAS 0:6 0:2 LSI SCSI 1:1 2:1 LSI SCSI 1:4 2:4 LSI SCSI 1:7 2:7 pvSCSI 2:2 1:2 pvSCSI 2:5 1:5 pvSCSI 2:8 1:8 My main question is why does this happen under Linux? The next question is: how do I get it fixed or fix it myself? If I was going to guess, I'd say it's an issue with how the kernel is handing out the SCSI host number and how the Linux SCSI driver (included with VMware tools) is detecting the SCSI target number. Perhaps the order the drivers are loaded also has something to do with the issue. I'm guessing this would not involve udev, but I could be wrong. Any thoughts would be appreciated. Thanks! PS. My environment is VMware, but I don't need an answer for these drivers specifically. I imagine this might be a problem with any SCSI driver under Linux.

    Read the article

  • Refresh Service List of a paired Bluetooth device !

    - by sas-san
    Hi- Is there any possibility to refresh the service list of a paired device in a programm? At the moment, i have to go to the bluetooth options and select the device properties of the bluetooth device and have to refresh the service list manually. Is there any API that RIMM provides to do programmatically? thanks,

    Read the article

  • Dell Poweredge R410 replace PERC S100 with PERC 6i

    - by Robe Eleckers
    I want to replace the PERC S100 RAID Controller with a PERC6i to be able to use 4 SAS harddrives instead of only SATA drives. What exactly do I need for this, what I've got so far: PERC6i PCIe x8 card. 4 x SAS 300GB 15000rpm drives Some questions I have Do I need a different backplane to accomodate the SAS disks? If so, what kind of backplane? Do I need a special cable to hookup the PERC6i with the backplane? If so, what kind of cable? Thanks.

    Read the article

  • Dell OpenManage Causing Periodic Slowness

    - by Zorlack
    Today we diagnosed the cause of a Periodic slowness issue: see here. Dell OpenManage Server Administrator seems to have been causing hourly slowness. It would occasionally peg one of the CPUs for upwards of two minutes. Disabling it drastically improved the performance of the SQL Server. The server hardware: Dell R710 Dual Quad Core 2.9GHz Processors 96GB Memory 2 Disk RAID 1 SAS System Disk (Internal) 4 Disk RAID 10 SAS Log Disk (Internal) 14 Disk RAID 10 SAS Data Disk (External DAS MD1000) Windows 2008 Enterprise R2 x64 We installed the OS using Dell OpenManage Server Assistant, so I assume that it was correctly configured. For now we have disabled OMSA to alleviate the performance issues it was causing, but I'd like to be able to re-enable it. Has anyone had a similar experience that can shed a little light on the nature of this problem?

    Read the article

  • Zero-channel RAID for High Performance MySQL Server (IBM ServeRAID 8k) : Any Experience/Recommendati

    - by prs563
    We are getting this IBM rack mount server and it has this IBM ServeRAID8k storage controller with Zero-Channel RAID and 256MB battery backed cache. It can support RAID 10 which we need for our high performance MySQL server which will have 4 x 15000K RPM 300GB SAS HDD. This is mission-critical and we want as much bandwidth and performance. Is this a good card or should we replace with another IBM RAID card? IBM ServeRAID 8k SAS Controller option provides 256 MB of battery backed 533 MHz DDR2 standard power memory in a fixed mounting arrangement. The device attaches directly to IBM planar which can provide full RAID capability. Manufacturer IBM Manufacturer Part # 25R8064 Cost Central Item # 10025907 Product Description IBM ServeRAID 8k SAS - Storage controller (zero-channel RAID) - RAID 0, 1, 5, 6, 10, 1E Device Type Storage controller (zero-channel RAID) - plug-in module Buffer Size 256 MB Supported Devices Disk array (RAID) Max Storage Devices Qty 8 RAID Level RAID 0, RAID 1, RAID 5, RAID 6, RAID 10, RAID 1E Manufacturer Warranty 1 year warranty

    Read the article