  • Timer to find elapsed time in a function call in C

    - by Mohit Nanda
    I want to calculate time elapsed during a function call in C, to the precision of 1 nanosecond. Is there a timer function available in C to do it? If yes please provide a sample code-snippet. Pseudo code Timer.Start() foo(); Timer.Stop() Display time elapsed in execution of foo() Environment details: - using gcc 3.4 compiler on a RHEL machine

    Read the article

  • Windows service installed successfully but not responding after started.

    - by Ridhi
    I have a windows service written in C#, .Net framework 2.0. I installed it on three machines and it worked fine but on one machine (with .Net framework 2.0) the setup has installed the service successfully but the service is not responding after I start it. I check for this by checking whether a log file is created at a specific path insribed in the config file or not. This log file is created everytime the timer elapses the interval time. I'm unable to figure out the reason. Have checked all the parameters but unable to get any solution to this. The funny thing is that the same setup is running well on other machines. P.S.: I have admin access on all the servers I'm installing this service on.

    Read the article

  • Accessing an Internal Function in setInterval

    - by Phonethics
    (function($) { $.fn.myPlugin = function(options) { var _this; var timer1; var foo = function(n) { if (timer1 != null) return; // in action timer1 = setInterval("bar("+n+")", 500); }; var bar = function(n) { ... if ( ... ) clearInterval(timer1); }; return this.each(function() { _this = $(this); _this.bind("click", function(){ foo(10); }); }); } })(jQuery); This doesn't work because "bar is not defined."

    Read the article

  • game performance

    - by iQue
    I'm making a game for android, and earlier today I was trying to add some cool stuff to my game. The problem is this thing needs like 5 timers. I build my timers like this: timer += deltaTime; if(timer >= 2.0f){ doStuff; timer -= 2.0f; } // this timers gets stuff done every 2 secs Will having to many timers like this, getting checked every frame, screw up my games performance? The effect I wanted to add was a crosshair every 2 sec, then remove it after 2 sec and do a timed animation. So an array of crosshairs dependent on a bunch of timers to be exact. This caused my game to shut down when used, so thats why Im wondering if using that many timers causes my game to flip out.

    Read the article

  • Is there a way to clear all JavaScript timers at once?

    - by Jens
    Im building an automatic refreshing comment section for my website using jQuery .load. So I am using a javascript 'setTimeout' timer to check for new comments. But after doing some stuff like changing comment pages or deleting (all using ajax), a few old timers keep running, even though I used clearTimeout before loading new ajax content. Is there some way to clear ALL javascript timers when I load new ajax content?

    Read the article

  • GTK+ widgets/windows being (randomly) corrupted, with what seems to be timers.

    - by nubela
    Hi, I have recently implemented a scrolling text across an area of limited screen estate using a timers repeating every 100ms, and some simple string appending. However, after this very implementation, I have come to realise that my GUI is getting randomly bugged/corrupted after a certain while. That is to say that some widgets/windows become completely white, and eventually the entire GUI turns white and unclickable. What is weird is that there is no error debug output at all. Having said that, I am using Mono with GTK-Sharp for the application. Does anyone have an idea or a possible clue how and why this is happening? If not, how can I further debug this properly? Thanks, really appreciate it. PS: Sometimes, it takes up to 1.5 hours for the thing to start corrupting, it has random timeframes for it to start happening. This is my the code implemented that caused this issue: void ScrollSyncTo(object sender, System.Timers.ElapsedEventArgs e) { //initial check if it fits nicely alr if (sync_to_full_txt.Length <= sync_to_max_char) { sync_to_timer.Stop(); return; } //check for pause if (sync_to_pause >= 0) { sync_to_pause--; return; } //check direction int temp_psn; string temp_str; if (sync_to_direction) { temp_psn = sync_to_posn + 1; if (sync_to_full_txt.Substring(temp_psn).Length < sync_to_max_char) { sync_to_pause = sync_to_break_steps; sync_to_direction = false; sync_to_posn = sync_to_full_txt.Length - 1; System.GC.Collect(); return; } else { temp_str = sync_to_full_txt.Substring(temp_psn, sync_to_max_char); } } else { temp_psn = sync_to_posn - 1; if (temp_psn + 1 < sync_to_max_char) { sync_to_pause = sync_to_break_steps; sync_to_direction = true; sync_to_posn = 0; System.GC.Collect(); return; } else { temp_str = sync_to_full_txt.Substring(temp_psn - sync_to_max_char + 1, sync_to_max_char); } } //lets move it sync_to.Text = temp_str; sync_to_posn = temp_psn; }

    Read the article

  • How to change the jtooltip timers for 1 component.

    - by i30817
    I have a component where i want to display a custom jtooltip. That is easy, just change the getTooltip method. Similar for location and text. However i also want to change the timers. The tooltip should always be displayed if the mouse is over a cellrenderer of the component. If it leaves all of those it should be turned invisible. I know that i can use TooltipManager to control the times globally. But the best solution is probably to just shortcircut that and display the tooltip myself with a mouselistener. However when i tried to do that (unregister the component in TooltipManager and setting the tooltip visible, with text and in the correct position, in a mouse listener) the tooltip never showed at all. What am i doing wrong?

    Read the article

  • FreeBSD 8.1 unstable network connection

    - by frankcheong
    I have three FreeBSD 8.1 running on three different hardware and therefore consist of different network adapter as well (bce, bge and igb). I found that the network connection is kind of unstable which I have tried to scp some 10MB file and found that I cannot always get the files completed successfully. I have further checked with my network admin and he claim that the problem is being caused by the network driver which cannot support the load whereby he tried to ping using huge packet size (around 15k) and my server will drop packet consistently at a regular interval. I found that this statement may not be valid since the three server is using three different network drive and it would be quite impossible that the same problem is being caused by three different network adapter and thus different network driver. Since then I have tried to tune up the performance by playing around with the /etc/sysctl.conf figures with no luck. kern.ipc.somaxconn=1024 kern.ipc.shmall=3276800 kern.ipc.shmmax=1638400000 # Security net.inet.ip.redirect=0 net.inet.ip.sourceroute=0 net.inet.ip.accept_sourceroute=0 net.inet.icmp.maskrepl=0 net.inet.icmp.log_redirect=0 net.inet.icmp.drop_redirect=1 net.inet.tcp.drop_synfin=1 # Security net.inet.udp.blackhole=1 net.inet.tcp.blackhole=2 # Required by pf net.inet.ip.forwarding=1 #Network Performance Tuning kern.ipc.maxsockbuf=16777216 net.inet.tcp.rfc1323=1 net.inet.tcp.sendbuf_max=16777216 net.inet.tcp.recvbuf_max=16777216 # Setting specifically for 1 or even 10Gbps network net.local.stream.sendspace=262144 net.local.stream.recvspace=262144 net.inet.tcp.local_slowstart_flightsize=10 net.inet.tcp.nolocaltimewait=1 net.inet.tcp.mssdflt=1460 net.inet.tcp.sendbuf_auto=1 net.inet.tcp.sendbuf_inc=16384 net.inet.tcp.recvbuf_auto=1 net.inet.tcp.recvbuf_inc=524288 net.inet.tcp.sendspace=262144 net.inet.tcp.recvspace=262144 net.inet.udp.recvspace=262144 kern.ipc.maxsockbuf=16777216 kern.ipc.nmbclusters=32768 net.inet.tcp.delayed_ack=1 net.inet.tcp.delacktime=100 net.inet.tcp.slowstart_flightsize=179 net.inet.tcp.inflight.enable=1 net.inet.tcp.inflight.min=6144 # Reduce the cache size of slow start connection net.inet.tcp.hostcache.expire=1 Our network admin also claim that they see quite a lot of network up and down from their cisco switch log while I cannot find any up down message inside the dmesg. Have further checked the netstat -s but dont have concrete idea. tcp: 133695291 packets sent 39408539 data packets (3358837321 bytes) 61868 data packets (89472844 bytes) retransmitted 24 data packets unnecessarily retransmitted 0 resends initiated by MTU discovery 50756141 ack-only packets (2148 delayed) 0 URG only packets 0 window probe packets 4372385 window update packets 39781869 control packets 134898031 packets received 72339403 acks (for 3357601899 bytes) 190712 duplicate acks 0 acks for unsent data 59339201 packets (3647021974 bytes) received in-sequence 114 completely duplicate packets (135202 bytes) 27 old duplicate packets 0 packets with some dup. data (0 bytes duped) 42090 out-of-order packets (60817889 bytes) 0 packets (0 bytes) of data after window 0 window probes 3953896 window update packets 64181 packets received after close 0 discarded for bad checksums 0 discarded for bad header offset fields 0 discarded because packet too short 45192 discarded due to memory problems 19945391 connection requests 1323420 connection accepts 0 bad connection attempts 0 listen queue overflows 0 ignored RSTs in the windows 21133581 connections established (including accepts) 21268724 connections closed (including 32737 drops) 207874 connections updated cached RTT on close 207874 connections updated cached RTT variance on close 132439 connections updated cached ssthresh on close 42392 embryonic connections dropped 72339338 segments updated rtt (of 69477829 attempts) 390871 retransmit timeouts 0 connections dropped by rexmit timeout 0 persist timeouts 0 connections dropped by persist timeout 0 Connections (fin_wait_2) dropped because of timeout 13990 keepalive timeouts 2 keepalive probes sent 13988 connections dropped by keepalive 173044 correct ACK header predictions 36947371 correct data packet header predictions 1323420 syncache entries added 0 retransmitted 0 dupsyn 0 dropped 1323420 completed 0 bucket overflow 0 cache overflow 0 reset 0 stale 0 aborted 0 badack 0 unreach 0 zone failures 1323420 cookies sent 0 cookies received 1864 SACK recovery episodes 18005 segment rexmits in SACK recovery episodes 26066896 byte rexmits in SACK recovery episodes 147327 SACK options (SACK blocks) received 87473 SACK options (SACK blocks) sent 0 SACK scoreboard overflow 0 packets with ECN CE bit set 0 packets with ECN ECT(0) bit set 0 packets with ECN ECT(1) bit set 0 successful ECN handshakes 0 times ECN reduced the congestion window udp: 5141258 datagrams received 0 with incomplete header 0 with bad data length field 0 with bad checksum 1 with no checksum 0 dropped due to no socket 129616 broadcast/multicast datagrams undelivered 0 dropped due to full socket buffers 0 not for hashed pcb 5011642 delivered 5016050 datagrams output 0 times multicast source filter matched sctp: 0 input packets 0 datagrams 0 packets that had data 0 input SACK chunks 0 input DATA chunks 0 duplicate DATA chunks 0 input HB chunks 0 HB-ACK chunks 0 input ECNE chunks 0 input AUTH chunks 0 chunks missing AUTH 0 invalid HMAC ids received 0 invalid secret ids received 0 auth failed 0 fast path receives all one chunk 0 fast path multi-part data 0 output packets 0 output SACKs 0 output DATA chunks 0 retransmitted DATA chunks 0 fast retransmitted DATA chunks 0 FR's that happened more than once to same chunk 0 intput HB chunks 0 output ECNE chunks 0 output AUTH chunks 0 ip_output error counter Packet drop statistics: 0 from middle box 0 from end host 0 with data 0 non-data, non-endhost 0 non-endhost, bandwidth rep only 0 not enough for chunk header 0 not enough data to confirm 0 where process_chunk_drop said break 0 failed to find TSN 0 attempt reverse TSN lookup 0 e-host confirms zero-rwnd 0 midbox confirms no space 0 data did not match TSN 0 TSN's marked for Fast Retran Timeouts: 0 iterator timers fired 0 T3 data time outs 0 window probe (T3) timers fired 0 INIT timers fired 0 sack timers fired 0 shutdown timers fired 0 heartbeat timers fired 0 a cookie timeout fired 0 an endpoint changed its cookiesecret 0 PMTU timers fired 0 shutdown ack timers fired 0 shutdown guard timers fired 0 stream reset timers fired 0 early FR timers fired 0 an asconf timer fired 0 auto close timer fired 0 asoc free timers expired 0 inp free timers expired 0 packet shorter than header 0 checksum error 0 no endpoint for port 0 bad v-tag 0 bad SID 0 no memory 0 number of multiple FR in a RTT window 0 RFC813 allowed sending 0 RFC813 does not allow sending 0 times max burst prohibited sending 0 look ahead tells us no memory in interface 0 numbers of window probes sent 0 times an output error to clamp down on next user send 0 times sctp_senderrors were caused from a user 0 number of in data drops due to chunk limit reached 0 number of in data drops due to rwnd limit reached 0 times a ECN reduced the cwnd 0 used express lookup via vtag 0 collision in express lookup 0 times the sender ran dry of user data on primary 0 same for above 0 sacks the slow way 0 window update only sacks sent 0 sends with sinfo_flags !=0 0 unordered sends 0 sends with EOF flag set 0 sends with ABORT flag set 0 times protocol drain called 0 times we did a protocol drain 0 times recv was called with peek 0 cached chunks used 0 cached stream oq's used 0 unread messages abandonded by close 0 send burst avoidance, already max burst inflight to net 0 send cwnd full avoidance, already max burst inflight to net 0 number of map array over-runs via fwd-tsn's ip: 137814085 total packets received 0 bad header checksums 0 with size smaller than minimum 0 with data size < data length 0 with ip length > max ip packet size 0 with header length < data size 0 with data length < header length 0 with bad options 0 with incorrect version number 1200 fragments received 0 fragments dropped (dup or out of space) 0 fragments dropped after timeout 300 packets reassembled ok 137813009 packets for this host 530 packets for unknown/unsupported protocol 0 packets forwarded (0 packets fast forwarded) 61 packets not forwardable 0 packets received for unknown multicast group 0 redirects sent 137234598 packets sent from this host 0 packets sent with fabricated ip header 685307 output packets dropped due to no bufs, etc. 52 output packets discarded due to no route 300 output datagrams fragmented 1200 fragments created 0 datagrams that can't be fragmented 0 tunneling packets that can't find gif 0 datagrams with bad address in header icmp: 0 calls to icmp_error 0 errors not generated in response to an icmp message Output histogram: echo reply: 305 0 messages with bad code fields 0 messages less than the minimum length 0 messages with bad checksum 0 messages with bad length 0 multicast echo requests ignored 0 multicast timestamp requests ignored Input histogram: destination unreachable: 530 echo: 305 305 message responses generated 0 invalid return addresses 0 no return routes ICMP address mask responses are disabled igmp: 0 messages received 0 messages received with too few bytes 0 messages received with wrong TTL 0 messages received with bad checksum 0 V1/V2 membership queries received 0 V3 membership queries received 0 membership queries received with invalid field(s) 0 general queries received 0 group queries received 0 group-source queries received 0 group-source queries dropped 0 membership reports received 0 membership reports received with invalid field(s) 0 membership reports received for groups to which we belong 0 V3 reports received without Router Alert 0 membership reports sent arp: 376748 ARP requests sent 3207 ARP replies sent 245245 ARP requests received 80845 ARP replies received 326090 ARP packets received 267712 total packets dropped due to no ARP entry 108876 ARP entrys timed out 0 Duplicate IPs seen ip6: 2226633 total packets received 0 with size smaller than minimum 0 with data size < data length 0 with bad options 0 with incorrect version number 0 fragments received 0 fragments dropped (dup or out of space) 0 fragments dropped after timeout 0 fragments that exceeded limit 0 packets reassembled ok 2226633 packets for this host 0 packets forwarded 0 packets not forwardable 0 redirects sent 2226633 packets sent from this host 0 packets sent with fabricated ip header 0 output packets dropped due to no bufs, etc. 8 output packets discarded due to no route 0 output datagrams fragmented 0 fragments created 0 datagrams that can't be fragmented 0 packets that violated scope rules 0 multicast packets which we don't join Input histogram: UDP: 2226633 Mbuf statistics: 962679 one mbuf 1263954 one ext mbuf 0 two or more ext mbuf 0 packets whose headers are not continuous 0 tunneling packets that can't find gif 0 packets discarded because of too many headers 0 failures of source address selection Source addresses selection rule applied: icmp6: 0 calls to icmp6_error 0 errors not generated in response to an icmp6 message 0 errors not generated because of rate limitation 0 messages with bad code fields 0 messages < minimum length 0 bad checksums 0 messages with bad length Histogram of error messages to be generated: 0 no route 0 administratively prohibited 0 beyond scope 0 address unreachable 0 port unreachable 0 packet too big 0 time exceed transit 0 time exceed reassembly 0 erroneous header field 0 unrecognized next header 0 unrecognized option 0 redirect 0 unknown 0 message responses generated 0 messages with too many ND options 0 messages with bad ND options 0 bad neighbor solicitation messages 0 bad neighbor advertisement messages 0 bad router solicitation messages 0 bad router advertisement messages 0 bad redirect messages 0 path MTU changes rip6: 0 messages received 0 checksum calculations on inbound 0 messages with bad checksum 0 messages dropped due to no socket 0 multicast messages dropped due to no socket 0 messages dropped due to full socket buffers 0 delivered 0 datagrams output netstat -m 516/5124/5640 mbufs in use (current/cache/total) 512/1634/2146/32768 mbuf clusters in use (current/cache/total/max) 512/1536 mbuf+clusters out of packet secondary zone in use (current/cache) 0/1303/1303/12800 4k (page size) jumbo clusters in use (current/cache/total/max) 0/0/0/6400 9k jumbo clusters in use (current/cache/total/max) 0/0/0/3200 16k jumbo clusters in use (current/cache/total/max) 1153K/9761K/10914K bytes allocated to network (current/cache/total) 0/0/0 requests for mbufs denied (mbufs/clusters/mbuf+clusters) 0/0/0 requests for jumbo clusters denied (4k/9k/16k) 0/8/6656 sfbufs in use (current/peak/max) 0 requests for sfbufs denied 0 requests for sfbufs delayed 0 requests for I/O initiated by sendfile 0 calls to protocol drain routines Anyone got an idea what might be the possible cause?

    Read the article

  • Why do Asp.net timers/updatepanels leak memory and can it be fixed/worked around?

    - by KallDrexx
    I have built a suite of internal websites for our company to manage some of our processes. I have been noticing that these pages have massive memory leaks that cause the pages to be using well over 150mb of memory, which is ridiculous for a webpage that consists of a single form and a GridView that is displaying 7-10 rows of data at a time, sometimes with the data not changing for a whole day. This data does need to be refreshed on a semi-regular basis so that we always see the latest results and can act on them. After some testing it appears that the memory leak is extremely easy to reproduce, and very noticeable. I created a page with the following asp.net markup: <body> <form id="form1" runat="server"> <div> <asp:scriptmanager ID="Scriptmanager1" runat="server"></asp:scriptmanager> <asp:Timer ID="timer1" runat="server" Interval="1000" /> <asp:UpdatePanel ID="UpdatePanel1" runat="server"> <ContentTemplate> </ContentTemplate> </asp:UpdatePanel> </div> </form> </body> There is absolutely no code behind for this. This is the entirety of the page. Running this site in Chrome shows the memory usage shoot up to 25 megs in the span of 20-30 seconds. Leaving it running for a few minutes makes the memory go up to the 70 megs and such. Am I using timers and update panels wrong, or is this a pure Asp.net issue with no work around?

    Read the article

  • C# - Alternative to System.Timers.Timer, to call a function at a specific time.

    - by Fábio Antunes
    Hello everybody. I want to call a specific function on my C# application at a specific time. At first i thought about using a Timer (System.Time.Timer), but that soon became impossible to use. Why? Simple. The Timer Class requires a Interval in milliseconds, but considering that i might want the function to be executed, lets says in a week that would mean: 7 Days = 168 hours; 168 Hours = 10,080 minutes; 10,080 Minutes = 6,048,000 seconds; 6,048,000 Seconds = 6,048,000,000 milliseconds; So the Interval would be 6,048,000,000; Now lets remember that the Interval accepted data type is int, and as we know int range goes from -2,147,483,648 to 2,147,483,647. That makes Timer useless in this case once we cannot set a Interval bigger that 2,147,483,647 milliseconds. So i need a solution where i could specify when the function should be called. Something like this: solution.ExecuteAt = "30-04-2010 15:10:00"; solution.Function = "functionName"; solution.Start(); So when the System Time would reach "30-04-2010 15:10:00" the function would be executed in the application. How can this problem be solved? Thanks just by taking the time to read my question. But if you could provide me with some help i would be most grateful. Additional Info: What these functions will do? Getting climate information and based on that info: Starting / Shutting down other Applications (most of them Console Based); Sending custom Commands to those Console Applications; Power down, Rebooting, Sleep, Hibernate the computer; And if possible schedule the BIOS to Power Up the Computer; EDIT: It would seem that the Interval accepted data type is double, however if you set a value bigger that an int to the Interval, and call Start() it throws a exception [0, Int32.MaxValue]. EDIT 2: Jørn Schou-Rode suggested using Ncron to handle the scheduling tasks, and at first look this seems a good solution, but i would like to hear about some who as worked with it.

    Read the article

  • The latest version of the EJB 3.2 spec available on java.net project

    - by Marina Vatkina
    If you are not following us on the users alias, here is a quick update. Just before JavaOne, I uploaded the latest version of the EJB 3.2 Core document to the ejb-spec.java.net downloads. If you want to see the detailed changes, download it If you are interested in the high-level list, or would like to know what to look for, this is the list of changes since the previous version (found on the same download page): Specified that the SessionContext object in a the singleton session bean is thread-safe Clarified that the EJB timers distribution and failover rules apply only to persistent timers Clarified that non-persistent timers returned by getTimers and getAllTimers methods are from the same JVM as the caller Fixed section numbering (left over after moving it to its own chapter) in Ch 17 Noted that only 3.0 and 3.1 deployment descriptors are required to be supported in EJB 3.2 Lite for prior versions of the applications Fixes for EJB_SPEC-61 (Ambiguity in EJB lite local view support) and EJB_SPEC-59 (Improve references to the component-defining annotations) JMS/MDB changes: added new standard activation properties and the unique identifier, and rearranged sections for easier navigation Fixed unresolved cross-refs Updated the rule: only local asynchronous session bean invocations are supported in EJB 3.2 Lite Synchronized permissions in the Table with the permissions listed for the EJB Components in the Java EE Platform Specification Table EE.6-2 Specified that during processing of the close() method, the embeddable container cancels all pending asynchronous invocations and non-persistent timers Updated most of the referenced documents to their latest versions Happy reading!

    Read the article

  • Access $('selector').data in functions/objects

    - by John
    How do I access values set by $.data() inside a function or object $('#timers').data('firsttimer', 100); //prints 100 document.write($('#timers').data('firsttimer')); function blah(){ //Prints nothing document.write($('#timers').data('firsttimer')); } blah(); See this jsfiddle for easy access to test the code http://jsfiddle.net/JUfd8/

    Read the article

  • Multiple windows services in a single project = mystery

    - by Remoh
    I'm having a bizarre issue that I haven't seen before and I'm thinking it MUST be something simple that I'm not seeing in my code. I have a project with 2 windows services defined. One I've called DataSyncService, the other SubscriptionService. Both are added to the same project installer. Both use a timer control from System.Timers. If I start both services together, they seem to work fine. The timers elapse at the appropriate time and everything looks okay. However, if I start either service individually, leaving the other stopped, everything goes haywire. The timer elapses constantly and on the wrong service. In other words, if I start the DataSyncService, the SubscriptionService timer elapses over and over. ...which is obviously strange. The setup is similar to what I've done in the past so I'm really stumped. I even tried deleting both service and starting over but it doesn't seem to make a difference. At this point, I'm thinking I've made a simple error in the way I'm defining the services and my brain just won't let me see it. It must be creating some sort of threading issue that causes one service to race when the other is stopped. Here the code.... From Program.cs: static void Main() { ServiceBase[] ServicesToRun; ServicesToRun = new ServiceBase[] { new DataSyncService(), new SubscriptionService() }; ServiceBase.Run(ServicesToRun); } From ProjectInstaller.designer.cs: private void InitializeComponent() { this.serviceProcessInstaller1 = new System.ServiceProcess.ServiceProcessInstaller(); this.dataSyncInstaller = new System.ServiceProcess.ServiceInstaller(); this.subscriptionInstaller = new System.ServiceProcess.ServiceInstaller(); // // serviceProcessInstaller1 // this.serviceProcessInstaller1.Account = System.ServiceProcess.ServiceAccount.LocalSystem; this.serviceProcessInstaller1.Password = null; this.serviceProcessInstaller1.Username = null; // // dataSyncInstaller // this.dataSyncInstaller.DisplayName = "Data Sync Service"; this.dataSyncInstaller.ServiceName = "DataSyncService"; this.dataSyncInstaller.StartType = System.ServiceProcess.ServiceStartMode.Automatic; // // subscriptionInstaller // this.subscriptionInstaller.DisplayName = "Subscription Service"; this.subscriptionInstaller.ServiceName = "SubscriptionService"; this.subscriptionInstaller.StartType = System.ServiceProcess.ServiceStartMode.Automatic; // // ProjectInstaller // this.Installers.AddRange(new System.Configuration.Install.Installer[] { this.serviceProcessInstaller1, this.dataSyncInstaller, this.subscriptionInstaller}); } private System.ServiceProcess.ServiceProcessInstaller serviceProcessInstaller1; private System.ServiceProcess.ServiceInstaller dataSyncInstaller; private System.ServiceProcess.ServiceInstaller subscriptionInstaller; From DataSyncService.cs: public static readonly int _defaultInterval = 43200000; //log4net.ILog log; public DataSyncService() { InitializeComponent(); //log = LogFactory.Instance.GetLogger(this); } protected override void OnStart(string[] args) { timer1.Interval = _defaultInterval; //GetInterval(); timer1.Enabled = true; EventLog.WriteEntry("MyProj", "Data Sync Service Started", EventLogEntryType.Information); //log.Info("Data Sync Service Started"); } private void timer1_Elapsed(object sender, System.Timers.ElapsedEventArgs e) { EventLog.WriteEntry("MyProj", "Data Sync Timer Elapsed.", EventLogEntryType.Information); } private void InitializeComponent() { this.timer1 = new System.Timers.Timer(); ((System.ComponentModel.ISupportInitialize)(this.timer1)).BeginInit(); // // timer1 // this.timer1.Enabled = true; this.timer1.Elapsed += new System.Timers.ElapsedEventHandler(this.timer1_Elapsed); // // DataSyncService // this.ServiceName = "DataSyncService"; ((System.ComponentModel.ISupportInitialize)(this.timer1)).EndInit(); } From SubscriptionService: public static readonly int _defaultInterval = 300000; //log4net.ILog log; public SubscriptionService() { InitializeComponent(); } protected override void OnStart(string[] args) { timer1.Interval = _defaultInterval; //GetInterval(); timer1.Enabled = true; EventLog.WriteEntry("MyProj", "Subscription Service Started", EventLogEntryType.Information); //log.Info("Subscription Service Started"); } private void timer1_Elapsed(object sender, System.Timers.ElapsedEventArgs e) { EventLog.WriteEntry("MyProj", "Subscription Service Time Elapsed", EventLogEntryType.Information); } private void InitializeComponent() //in designer { this.timer1 = new System.Timers.Timer(); ((System.ComponentModel.ISupportInitialize)(this.timer1)).BeginInit(); // // timer1 // this.timer1.Enabled = true; this.timer1.Elapsed += new System.Timers.ElapsedEventHandler(this.timer1_Elapsed); // // SubscriptionService // this.ServiceName = "SubscriptionService"; ((System.ComponentModel.ISupportInitialize)(this.timer1)).EndInit(); } Again, the problem is that the timer1_elapsed handler runs constantly when only one of the services is started. And it's the handler on the OPPOSITE service. Anybody see anything?

    Read the article

  • HPET for x86 BSP (how to build it for WCE8)

    - by Werner Willemsens
    Originally posted on: http://geekswithblogs.net/WernerWillemsens/archive/2014/08/02/157895.aspx"I needed a timer". That is how we started a few blogs ago our series about APIC and ACPI. Well, here it is. HPET (High Precision Event Timer) was introduced by Intel in early 2000 to: Replace old style Intel 8253 (1981!) and 8254 timers Support more accurate timers that could be used for multimedia purposes. Hence Microsoft and Intel sometimes refers to HPET as Multimedia timers. An HPET chip consists of a 64-bit up-counter (main counter) counting at a frequency of at least 10 MHz, and a set of (at least three, up to 256) comparators. These comparators are 32- or 64-bit wide. The HPET is discoverable via ACPI. The HPET circuit in recent Intel platforms is integrated into the SouthBridge chip (e.g. 82801) All HPET timers should support one-shot interrupt programming, while optionally they can support periodic interrupts. In most Intel SouthBridges I worked with, there are three HPET timers. TIMER0 supports both one-shot and periodic mode, while TIMER1 and TIMER2 are one-shot only. Each HPET timer can generate interrupts, both in old-style PIC mode and in APIC mode. However in PIC mode, interrupts cannot freely be chosen. Typically IRQ11 is available and cannot be shared with any other interrupt! Which makes the HPET in PIC mode virtually unusable. In APIC mode however more IRQs are available and can be shared with other interrupt generating devices. (Check the datasheet of your SouthBridge) Because of this higher level of freedom, I created the APIC BSP (see previous posts). The HPET driver code that I present you here uses this APIC mode. Hpet.reg [HKEY_LOCAL_MACHINE\Drivers\BuiltIn\Hpet] "Dll"="Hpet.dll" "Prefix"="HPT" "Order"=dword:10 "IsrDll"="giisr.dll" "IsrHandler"="ISRHandler" "Priority256"=dword:50 Because HPET does not reside on the PCI bus, but can be found through ACPI as a memory mapped device, you don't need to specify the "Class", "SubClass", "ProgIF" and other PCI related registry keys that you typically find for PCI devices. If a driver needs to run its internal thread(s) at a certain priority level, by convention in Windows CE you add the "Priority256" registry key. Through this key you can easily play with the driver's thread priority for better response and timer accuracy. See later. Hpet.cpp (Hpet.dll) This cpp file contains the complete HPET driver code. The file is part of a folder that you typically integrate in your BSP (\src\drivers\Hpet). It is written as sample (example) code, you most likely want to change this code to your specific needs. There are two sets of #define's that I use to control how the driver works. _TRIGGER_EVENT or _TRIGGER_SEMAPHORE: _TRIGGER_EVENT will let your driver trigger a Windows CE Event when the timer expires, _TRIGGER_SEMAPHORE will trigger a Windows CE counting Semaphore. The latter guarantees that no events get lost in case your application cannot always process the triggers fast enough. _TIMER0 or _TIMER2: both timers will trigger an event or semaphore periodically. _TIMER0 will use a periodic HPET timer interrupt, while _TIMER2 will reprogram a one-shot HPET timer after each interrupt. The one-shot approach is interesting if the frequency you wish to generate is not an even multiple of the HPET main counter frequency. The sample code uses an algorithm to generate a more correct frequency over a longer period (by reducing rounding errors). _TIMER1 is not used in the sample source code. HPT_Init() will locate the HPET I/O memory space, setup the HPET counter (_TIMER0 or _TIMER2) and install the Interrupt Service Thread (IST). Upon timer expiration, the IST will run and on its turn will generate a Windows CE Event or Semaphore. In case of _TIMER2 a new one-shot comparator value is calculated and set for the timer. The IRQ of the HPET timers are programmed to IRQ22, but you can choose typically from 20-23. The TIMERn_INT_ROUT_CAP bits in the TIMn_CONF register will tell you what IRQs you can choose from. HPT_IOControl() can be used to set a new HPET counter frequency (actually you configure the counter timeout value in microseconds), start and stop the timer, and request the current HPET counter value. The latter is interesting because the Windows CE QueryPerformanceCounter() and QueryPerformanceFrequency() APIs implement the same functionality, albeit based on other counter implementations. HpetDrvIst() contains the IST code. DWORD WINAPI HpetDrvIst(LPVOID lpArg) { psHpetDeviceContext pHwContext = (psHpetDeviceContext)lpArg; DWORD mainCount = READDWORD(pHwContext->g_hpet_va, GenCapIDReg + 4); // Main Counter Tick period (fempto sec 10E-15) DWORD i = 0; while (1) { WaitForSingleObject(pHwContext->g_isrEvent, INFINITE); #if defined(_TRIGGER_SEMAPHORE) LONG p = 0; BOOL b = ReleaseSemaphore(pHwContext->g_triggerEvent, 1, &p); #elif defined(_TRIGGER_EVENT) BOOL b = SetEvent(pHwContext->g_triggerEvent); #else #pragma error("Unknown TRIGGER") #endif #if defined(_TIMER0) DWORD currentCount = READDWORD(pHwContext->g_hpet_va, MainCounterReg); DWORD comparator = READDWORD(pHwContext->g_hpet_va, Tim0_ComparatorReg + 0); SETBIT(pHwContext->g_hpet_va, GenIntStaReg, 0); // clear interrupt on HPET level InterruptDone(pHwContext->g_sysIntr); // clear interrupt on OS level _LOGMSG(ZONE_INTERRUPT, (L"%s: HpetDrvIst 0 %06d %08X %08X", pHwContext->g_id, i++, currentCount, comparator)); #elif defined(_TIMER2) DWORD currentCount = READDWORD(pHwContext->g_hpet_va, MainCounterReg); DWORD previousComparator = READDWORD(pHwContext->g_hpet_va, Tim2_ComparatorReg + 0); pHwContext->g_counter2.QuadPart += pHwContext->g_comparator.QuadPart; // increment virtual counter (higher accuracy) DWORD comparator = (DWORD)(pHwContext->g_counter2.QuadPart >> 8); // "round" to real value WRITEDWORD(pHwContext->g_hpet_va, Tim2_ComparatorReg + 0, comparator); SETBIT(pHwContext->g_hpet_va, GenIntStaReg, 2); // clear interrupt on HPET level InterruptDone(pHwContext->g_sysIntr); // clear interrupt on OS level _LOGMSG(ZONE_INTERRUPT, (L"%s: HpetDrvIst 2 %06d %08X %08X (%08X)", pHwContext->g_id, i++, currentCount, comparator, comparator - previousComparator)); #else #pragma error("Unknown TIMER") #endif } return 1; } The following figure shows how the HPET hardware interrupt via ISR -> IST is translated in a Windows CE Event or Semaphore by the HPET driver. The Event or Semaphore can be used to trigger a Windows CE application. HpetTest.cpp (HpetTest.exe)This cpp file contains sample source how to use the HPET driver from an application. The file is part of a separate (smart device) VS2013 solution. It contains code to measure the generated Event/Semaphore times by means of GetSystemTime() and QueryPerformanceCounter() and QueryPerformanceFrequency() APIs. HPET evaluation If you scan the internet about HPET, you'll find many remarks about buggy HPET implementations and bad performance. Unfortunately that is true. I tested the HPET driver on an Intel ICH7M SBC (release date 2008). When a HPET timer expires on the ICH7M, an interrupt indeed is generated, but right after you clear the interrupt, a few more unwanted interrupts (too soon!) occur as well. I tested and debugged it for a loooong time, but I couldn't get it to work. I concluded ICH7M's HPET is buggy Intel hardware. I tested the HPET driver successfully on a more recent NM10 SBC (release date 2013). With the NM10 chipset however, I am not fully convinced about the timer's frequency accuracy. In the long run - on average - all is fine, but occasionally I experienced upto 20 microseconds delays (which were immediately compensated on the next interrupt). Of course, this was all measured by software, but I still experienced the occasional delay when both the HPET driver IST thread as the application thread ran at CeSetThreadPriority(1). If it is not the hardware, only the kernel can cause this delay. But Windows CE is an RTOS and I have never experienced such long delays with previous versions of Windows CE. I tested and developed this on WCE8, I am not heavily experienced with it yet. Internet forum threads however mention inaccurate HPET timer implementations as well. At this moment I haven't figured out what is going on here. Useful references: http://www.intel.com/content/dam/www/public/us/en/documents/technical-specifications/software-developers-hpet-spec-1-0a.pdf http://en.wikipedia.org/wiki/High_Precision_Event_Timer http://wiki.osdev.org/HPET Windows CE BSP source file package for HPET in MyBsp Note that this source code is "As Is". It is still under development and I cannot (and never will) guarantee the correctness of the code. Use it as a guide for your own HPET integration.

    Read the article

  • Blog Posts from Prepping for Last Year's Summit

    - by RickHeiges
    Last year, I had a series of blog posts that matched up with a webcast I did targeting First Timers to the PASS Summit 2011. Here is a link to the final blog post which is a summary of those posts and links to the main points in the series. A good deal of the information in those posts are still relevant. I am in the process of updating the webcast and will be presenting the information again this year on Oct 25, 2012 at 11am ET. There is a lot of great information out there for first timers that...(read more)

    Read the article

  • PASS: Board Q&amp;A at the Summit

    - by Bill Graziano
    The last two years we’ve put the Board in front of the members and taken questions.  We’re going to do that again this year.  It will be in Room 307/308 from 12:15 to 1:30 on Friday. Yes, this time overlaps with the Birds of a Feather Lunch and the start of afternoon sessions – but only partially.  You can attend the Q&A and still get to parts of both of those.  There just isn’t a great time to do this.  Every time overlaps with something. We can’t do it after the last session on Friday.  We can’t fit it between the last session and the evening events on Wednesday or Thursday.  We had some discussion around breakfast time but I didn’t think that was realistic.  This is the least bad time we could come up with. Last year we had 60-70 people attend.  These are the items that were specific things that I could work on: The first question was whether to increase transparency around individual votes of Board members.  We approved this at the Board meeting the following day.  The only caveat was that if the Board is given confidential information as a basis for their vote then we may not be able to disclose individual votes.  Putting a Director in a position where they can’t publicly defend the reason for their vote is a difficult situation.  Thanks Kendal! Can we have a Board member discretionary fund?  As background, I took a couple of people to lunch so we could have a quiet place to talk.  I bought lunch but wasn’t able to expense it back to PASS.  We just don’t have a budget item for things like this.  I think we should.  I would guess the entire Board would like it also.  It was in an earlier version of the budget but came out as part of a cost-cutting move to balance the budget.  I’d like to see it added back in but we’ll have to see. I know there were a comments about the elections.  At this point we had created the Election Review Committee.  I’ve already written at length about this process. Where does IT work go?  PASS started to publish our internal management reports starting in December 2010.  You can find them on our Governance page.  These aren’t filtered at all and include a variety of information about IT projects.  The most recent update had roughly a page of updates related to IT.  Lots of the work was related to Summit and the Orator tool that we use to manage speaker submissions. There were numerous requests that Tina Turner not be repeated.  Done.  I don’t think we’ll do anything quite like that again.  We had a request for a payment plan for Summit.  We looked into this briefly but didn’t take any action.  We didn’t think the effort was worth the small number of people that would use it.  If you disagree, submit this on our Summit Feedback site and get some votes. There were lots of suggestions around the first-timers events – especially from first timers.  You can find all our current activities related to first-timers at the First Timers page on the Summit web site.  Plus links to 34 (!) blog posts on suggestions for first-timers.  And a big THANK YOU to Confio and Red Gate for sponsoring this. I hope you get the chance to attend.  These events are very helpful to me as a Board member.  I like being able to look around the room as comments are being made and see the audience reaction.  It helps me gauge the interest in an idea. I’d also like to direct you to the Summit Feedback site.  You can submit and vote on ideas to make the Summit a better experience.  As of right now we have the suggestions from last year still up.  We may reset these prior to the Summit though.

    Read the article

  • How can I use timer to stop another thread? [on hold]

    - by Haoda Fu
    How can we stop another thread based on a timer? I was trying to use timer to stop another thread. But I didn't got a success. To better illustrate my point and for your easy to understand the key issue. I made the following sample example. Your help is really appreciated using System; using System.Collections.Generic; using System.Text; using System.Threading; using System.Timers; namespace TestCodes { public static class Program { private static Thread nT = new Thread(PrintABC); private static System.Timers.Timer aTimer; public static void Main() { aTimer = new System.Timers.Timer(1000); aTimer.Elapsed += TimerCallback; aTimer.Interval = 1000; aTimer.Enabled = true; nT.Start(); Console.ReadLine(); } private static void TimerCallback(Object o, ElapsedEventArgs e) { nT.Join(); Console.WriteLine("Complete the PrintABC"); GC.Collect(); } private static void PrintABC() { for (int iter = 1; iter < 300; iter++) { Console.WriteLine(iter+"abc"); Console.ReadKey(); //Thread.Sleep(100); } } } }

    Read the article

  • c# multi inheritance

    - by user326839
    So ive got a base class which requires a Socket: class Sock { public Socket s; public Sock(Socket s) { this.s = s; } public virtual void Process(byte[] data) { } ... } then ive got another class. if a new socket gets accepted a new instance of this class will be created: class Game : Sock { public Random Random = new Random(); public Timerr Timers; public Test Test; public Game(Socket s) : base(s) { } public static void ReceiveNewSocket(object s) { Game Client = new Game((Socket)s); Client.Start(); } public override void Process(byte[] buf) { Timers = new Timerr(s); Test = new Test(s); Test.T(); } } in the Sock class ive got a virtual function that gets overwritten by the Game class.(Process function) in this function im calling a function from the Test Class(Test+ Timerr Class: class Test : Game { public Test(Socket s) : base(s) { } public void T() { Console.WriteLine(Random.Next(0, 10)); Timers.Start(); } } class Timerr : Game { public Timerr(Socket s) : base(s) { } public void Start() { Console.WriteLine("test"); } } ) So in the Process function im calling a function in Test. And in this function(T) i need to call a function from the Timerr Class.But the problem is its always NULL , although the constructor is called in Process. And e.g. the Random Class can be called, i guess its because its defined with the constructor.: public Random Random = new Random(); and thats why the other classes(without a constructor): public Timerr Timers; public Test Test; are always null in the inherited class Test.But its essentiel that i call other Methods of other classes in this function.How could i solve that?

    Read the article

  • How can i add to dataGridView1 a data to the last row/column?

    - by user3681442
    In top of form1 i did: private System.Timers.Timer _refreshTimer; private int _thisProcess; Then in the Form1 Load event: _thisProcess = Process.GetCurrentProcess().Id; InitializeRefreshTimer(); PopulateApplications(); Then the timer init method: void InitializeRefreshTimer() { _refreshTimer = new System.Timers.Timer(5000); _refreshTimer.SynchronizingObject = this; _refreshTimer.Elapsed += new System.Timers.ElapsedEventHandler(TimerToUpdate_Elapsed); _refreshTimer.Start(); } Then the timer elapsed event: void TimerToUpdate_Elapsed(object sender, System.Timers.ElapsedEventArgs e) { PopulateApplications(); } In the end the Populate method: void PopulateApplications() { dataGridView1.Rows.Clear(); foreach (Process p in Process.GetProcesses(".")) { if (p.Id != _thisProcess) { try { if (p.MainWindowTitle.Length > 0) { String status = p.Responding ? "Running" : "Not Responding"; dataGridView1.Rows.Add( p.MainWindowTitle, status); } } catch { } } } } The variable status show in the column2 but let's say i want that status will be display for each process/app in column5 ? How can i move it ? EDIT** Tried this: void PopulateApplications() { dataGridView1.Rows.Clear(); foreach (Process p in Process.GetProcesses(".")) { if (p.Id != _thisProcess) { try { if (p.MainWindowTitle.Length > 0) { var icon = Icon.ExtractAssociatedIcon(p.MainModule.FileName); Image ima = icon.ToBitmap(); img.Image = ima; img.HeaderText = "Image"; img.Name = "img"; String status = p.Responding ? "Running" : "Not Responding"; dataGridView1.Rows.Add(img, p.MainWindowTitle, status); } } catch { } } } } I moved the variable img to the top of the form. The problem is i see in each row this: DataGridViewImageColumn { Name=img, Index=-1 } And i don't see the icon it self. Why ?

    Read the article

  • Scheduled task with windows services and system.timer.timer

    - by nccsbim071
    Hi i want implement a windows services scheduled task. I already created windows service. In a service i have implemented a timer.The timer is initialized at class interval. The timers interval is set in the start method of service and also it is enabled in the start method of the service. After timers elapsed event is fire i have done some actions. My problem is that, i am in a dilemma. Lets say the action i have done in Elapsed event, lets say take one hour and the timers interval is set to half an hour. so there are chances that even if the previous call to elapsed event has not ended new call to elapsed event will occur. my question will there be any conflict or is it ok or shall i use threads. please give some advice

    Read the article

  • How do I let main thread wait for the Timer.timer

    - by Kelvin
    Hi I am using System.Timer.Timer I always get NULL after running my programme and it only works if I add this.sleep(6000). Suppose the reason is the main thread ends but the timer hasn't finished ... Here is the class and I call the class from my main form. Class class1 { string finalResult = ""; public string getNumber() { RunTimer(); return finalResult; } pubic void RunTimer () { timer = new System.Timers.Timer(6000); timer.Interval = 1000; timer.Elapsed += new System.Timers.ElapsedEventHandler(cal); timer.Start(); } private void cal(object sender,System.Timers.ElapsedEventArgs e) { finalResult = READFROMCOMPORT; } }

    Read the article

  • How do I let main thread suspend and wait for the System.Timer.Timer running

    - by Kelvin
    Hi I am using System.Timer.Timer I always get NULL after running my programme and it only works if I add this.sleep(6000). Suppose the reason is the main thread ends but the timer hasn't finished ... Here is the class and I call the class from my main form. Class class1 { string finalResult = ""; public string getNumber() { RunTimer(); return finalResult; } pubic void RunTimer () { timer = new System.Timers.Timer(30000); timer.Interval = 1000; timer.Elapsed += new System.Timers.ElapsedEventHandler(cal); timer.Start(); } private void cal(object sender,System.Timers.ElapsedEventArgs e) { finalResult += READFROMCOMPORT; } }

    Read the article

  • Delay command execution over sockets

    - by David
    I've been trying to fix the game loop in a real time (tick delay) MUD. I realized using Thread.Sleep would seem clunky when the user spammed commands through their choice of client (Zmud, etc) e.g. east;south;southwest would wait three move ticks and then output everything from the past couple rooms. The game loop basically calls a Flush and Fill method for each socket during each tick (50ms) private void DoLoop() { Stopwatch stopWatch = new Stopwatch(); stopWatch.Start(); while (running) { // for each socket, flush and fill ConnectionMonitor.Update(); stopWatch.Stop(); WaitIfNeeded(stopWatch.ElapsedMilliseconds); stopWatch.Reset(); } } The Fill method fires the command events, but as mentioned before, they currently block using Thread.Sleep. I tried adding a "ready" flag to the state object that attempts to execute the command along with a queue of spammed commands, but it ends up executing one command and queuing up the rest i.e. each subsequent command executes something that got queued up that should've been executed before. I must be missing something about the timer. private readonly Queue<SpammedCommand> queuedCommands = new Queue<SpammedCommand>(); private bool ready = true; private void TryExecuteCommand(string input) { var commandContext = CommandContext.Create(input); var player = Server.Current.Database.Get<Player>(Session.Player.Key); var commandInfo = Server.Current.CommandLookup .FindCommand(commandContext.CommandName, player.IsAdmin); if (commandInfo != null) { if (!ready) { // queue command queuedCommands.Enqueue(new SpammedCommand() { Context = commandContext, Info = commandInfo }); return; } if (queuedCommands.Count > 0) { // queue the incoming command queuedCommands.Enqueue(new SpammedCommand() { Context = commandContext, Info = commandInfo, }); // dequeue and execute var command = queuedCommands.Dequeue(); command.Info.Command.Execute(Session, command.Context); setTimeout(command.Info.TickLength); return; } commandInfo.Command.Execute(Session, commandContext); setTimeout(commandInfo.TickLength); } else { Session.WriteLine("Command not recognized"); } } Finally, setTimeout was supposed to set the execution delay (TickLength) for that command, and makeReady just sets the ready flag on the state object to true. private void setTimeout(TickDelay tickDelay) { ready = false; var t = new System.Timers.Timer() { Interval = (long) tickDelay, AutoReset = false, }; t.Elapsed += makeReady; t.Start(); // fire this in tickDelay ms } // MAKE READYYYYY!!!! private void makeReady(object sender, System.Timers.ElapsedEventArgs e) { ready = true; } Am I missing something about the System.Timers.Timer created in setTimeout? How can I execute (and output) spammed commands per TickLength without using Thread.Sleep?