Search Results

Search found 3312 results on 133 pages for 'freebsd ports'.

Page 30/133 | < Previous Page | 26 27 28 29 30 31 32 33 34 35 36 37  | Next Page >

  • How to understand the LSI HBA connector specs?

    - by Sandra
    When reading the specifications for the LSi SAS 9206-16e HBA, it says Storage Connectivity; Data Transfer Rates * 16 ports; 6Gb/s SAS 2.1 compliant SAS Bandwidth * Half Duplex 2400MB/s, x4, 6Gb/s SAS lanes Port Configurations * 16 ea, x1 ports (individual drives) * 4 ea, x4 wide ports * 2ea, x8 wide ports Connectors * Four (x4) mini-SAS HD external connectors (SFF8644) So there are 4 physical connectors. Question What is the bandwidth for each of the connectors? I would be temped to say 6Gb/s * 4, but then it mentions the "Port Configurations" and 2ea, 4ea, 16ea, which I don't understand what is. Does this mean, that the 4 physical connectors are not identical?

    Read the article

  • SQL Server 2008 Remote Access

    - by Timothy Strimple
    I'm having problems connecting to my SQL Server 2008 database from my computer. I have enabled remote connections as described in this answer (http://serverfault.com/questions/7798/how-to-enable-remote-connections-for-sql-server-2008). And I have added the ports listed on the microsoft support page to our Cisco Asa firewall and I'm still unable to connect. The error I'm getting from the SQL Management Studio is: A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. (provider: TCP Provider, error: 0 - A connection attempt failed because the connected party did not properly respond after a period of time, or established connection failed because connected host has failed to respond.) (Microsoft SQL Server, Error: 10060) Once again, I have double and triple checked that remote connections are enabled under the database properties and that TCP is enabled on the configuration page. I've added tcp ports 135, 1433, 1434, 2382, 2383, and 4022 as well as udp 1434 to the firewall. I've also checked to make sure that 1433 is the static port that is set in the tcp section of the database server configuration. The ports should be configured correctly in the firewall since http/https and rdp are all working and the sql server ports are setup the same way. What am I missing here? Any help you could offer would be greatly appreciated. Edit: I can connect to the server via TCP on the internal network. The servers are colocated in a datacenter and I can connect from my production box to my development box and vice versa. To me that indicates a firewall issue, but I've no idea what else to open. I've even tried allowing all tcp ports to that server without success.

    Read the article

  • Determining the health of a Cisco switch port?

    - by ewwhite
    I've been chasing a packet-loss and network stability issue for a handful of end-users on an internal network for the past few days... These issues surfaced recently, however, the location was struck by lightning six weeks ago. I was seeing 5-10% packet loss between a stack of four Cisco 2960's and several PC's and phones on the other side of a 77-meter run. The PC's were run inline with the phones over a trunked link. We were seeing dropped calls and interruptions in client-server applications and Microsoft Exchange connectivity. I tried the usual troubleshooting steps remotely, having a local technician do the following during breaks in user and production activity: change cables between the wall jack and device. change patch cables between the patch panel and switch port(s). try different switch ports within the 2960 stack. change end-user devices with known-good equipment (new phones, different PC's). clear switch port interface counters and monitor incrementing errors closely. (Pastebin output of sh int) Pored over the device logs and Observium RRD graphs. No link up/down issues from the switch side. change power strips on the end-user side. test cable runs from the Cisco 2960 using test cable-diagnostics tdr int Gi4/0/9 (clean)* test cable runs with a Tripp-Lite cable tester. (clean) run diagnostics on the switch stack members. (clean) In the end, it took three changes of switch ports to find a stable solution. The only logical conclusion is that a few Cisco 2960 switch ports are bad or flaky... Not dead, but not consistent in behavior either. I'm not used to seeing individual ports die in this manner. What else can I test or check to determine if these devices are bad? Is it common for single ports to have problems, rather than a contiguous bank of ports? BTW - show cable-diagnostics tdr int Gi4/0/14 is very cool... Interface Speed Local pair Pair length Remote pair Pair status --------- ----- ---------- ------------------ ----------- -------------------- Gi4/0/14 1000M Pair A 79 +/- 0 meters Pair B Normal Pair B 75 +/- 0 meters Pair A Normal Pair C 77 +/- 0 meters Pair D Normal Pair D 79 +/- 0 meters Pair C Normal

    Read the article

  • Port forwarding no longer works

    - by Auryn
    Prior to testing an OpenVPN installation, I setup a basic VPN server using the software already built into Windows 7. Port forwarding on the Linksys router worked as normal and I was able to connect remotely. After doing an install of OpenVPN Access Server on a spare box running Ubuntu, and adding new ports to be forwarded I was unable to access the VPN from an external source as the required ports all indicated that they were closed. (During testing XRDP and VNCSERVER were also installed to facilitate access to the box) Checking back on the Windows 7 VPN resulted in no access to that vpn setup either. All ports are now reporting a being closed despite being previously open even ports that were being used for other services. Adding and removing port forwarding rules seem to have no effect. At this point, in order to troubleshoot, both the firewall and anti-virus software have been disabled on the Windows 7 machine. Could this be just a router issue? Is there any way out of this without having to reset and reconfigure the router?

    Read the article

  • cannot send emails to other Web servers

    - by developer
    I'm trying to limit my server's open ports in CSF. The IPv4 port settings include: # Allow incoming TCP ports TCP_IN = "22,25,53,80,110,143,443,587,3654,53343” # Allow outgoing TCP ports TCP_OUT = "22,53,80,113,443,465,995,3654" # Allow incoming UDP ports UDP_IN = "53" # Allow outgoing UDP ports # To allow outgoing traceroute add 33434:33523 to this list UDP_OUT = "53,113,123" As you see, I have port 25 open in TCP_IN but have removed it from TCP_OUT. The reason is I wanted to have my mails transmitted over smtps, so I have port 465 opened instead in TCP_OUT. Since I am using Rouncube in Directpanel, I have also set the following in Rouncube's config.inc.php: $config['default_host'] = 'ssl://mail.mydomain.com'; $config['smtp_server'] = 'ssl://mail.mydomain.com'; $config['smtp_port'] = 465; However, when I remove port 25 from TCP_OUT, I no longer can send mails, say, to gmail, though I can send mails to own. But I can receive all mails. Please let me know if I need to make any further changes. Do I need to disable port 25 at all, to have my mails sent via ssl. Thanks

    Read the article

  • Windows Server 2008 - unable to bind any TCP port

    - by Kalphiter
    OS: Win Server 2008 RC2 Windows firewall on (no effect when off) I have suddenly been plagued by an issue in which I cannot find any similar ones with a search. I am running about 20 game servers that bind to a UDP port, then bind to a TCP port 1 above the UDP port. Suddenly, a day ago, new TCP binds stopped functioning. Now, I have confirmed that other applications cannot listen on most ports. For example, I have a java program that I made a copy of, and tried the following ports: 33001, 23789, 89... completely random ports. As far as the applications already that have TCP bindings, such as HTTP and MySQL, only port 8080 was one port I discovered could work, and only for Apache. If applications would leave their default port they could not bind, however they returned to normal when the port was default. I've checked for listening applications through netstat and curports, also checked for any connections on these ports, and they're completely free.

    Read the article

  • Can't transfer images from a camera connected to usb2 port on a pcmcia adapter

    - by agnul
    I have an old laptop (HP OmniBook vt6200, WinXp pro, sp2) that only has usb1 ports. Transferring pictures from a digital camera is too slow, so I thought of trying one of those pccards carrying usb2 ports (D-Link Dub C2 in my case). Connecting the camera to one of the ports on the pccard, Picasa seems to freeze trying to read the camera contents, until I either disconnect the camera or the pccard. Any idea on what's wrong?

    Read the article

  • please demystify the 10Gb ethernet interfaces, cables

    - by maruti
    this really is a Dell question but tempted to ask the experts @ serverfault. choosen a Dell powerconnect 8024 10GbE switch. per the spec sheet this has 10GbaseT ports. "24x 10GBASE-T (10Gb/1Gb/100Mb) with 4x Combo Ports of SFP+ (10Gb/1Gb) or 10GBASE-T" the HBA on my storage server has 10G CX4 copper ports Dell does not sell any cables and this adds to my confusion. from the picture Dell 8024 seems to have RJ-45 type ports on the front panel? my question: is it a RJ-45 + CX4 cable or CX4 + CX4 cable?

    Read the article

  • Is my Cisco switch port bad?

    - by ewwhite
    I've been chasing a packet-loss and network stability issue for a handful of end-users on an internal network for the past few days... These issues surfaced last week, however the location was struck by lightning six weeks ago. I was seeing 5-10% packet loss between a stack of four Cisco 2960's and several PC's and phones on the other side of a 77-meter run. The PC's were run inline with the phones over a trunked link (switchport configuration pastebin). We were seeing dropped calls and interruptions in client-server applications and Microsoft Exchange connectivity. I tried the usual troubleshooting steps remotely, having a local technician do the following during breaks in user and production activity: change cables between the wall jack and device. change patch cables between the patch panel and switch port(s). try different switch ports within the 2960 stack. change end-user devices with known-good equipment (new phones, different PC's). clear switch port interface counters and monitor incrementing errors closely. (Pastebin output of sh int) Pored over the device logs and Observium RRD graphs. No link up/down issues from the switch side. change power strips on the end-user side. test cable runs from the Cisco 2960 using test cable-diagnostics tdr int Gi4/0/9 (clean)* test cable runs with a Tripp-Lite cable tester. (clean) run diagnostics on the switch stack members. (clean) In the end, it took three changes of switch ports to find a stable solution. The only logical conclusion is that a few Cisco 2960 switch ports are bad or flaky... Not dead, but not consistent in behavior either. I'm not used to seeing individual ports die in this manner. What else can I test or check to determine if these devices are bad? Is it common for single ports to have problems, rather than a contiguous bank of ports? BTW - show cable-diagnostics tdr int Gi4/0/14 is very cool... Interface Speed Local pair Pair length Remote pair Pair status --------- ----- ---------- ------------------ ----------- -------------------- Gi4/0/14 1000M Pair A 79 +/- 0 meters Pair B Normal Pair B 75 +/- 0 meters Pair A Normal Pair C 77 +/- 0 meters Pair D Normal Pair D 79 +/- 0 meters Pair C Normal

    Read the article

  • iptables - quick safety eval & limit max conns over time

    - by Peter Hanneman
    Working on locking down a *nix server box with some fancy iptable(v1.4.4) rules. I'm approaching the matter with a "paranoid, everyone's out to get me" style, not necessarily because I expect the box to be a hacker magnet but rather just for the sake of learning iptables and *nix security more throughly. Everything is well commented - so if anyone sees something I missed please let me know! The *nat table's "--to-ports" point to the only ports with actively listening services. (aside from pings) Layer 2 apps listen exclusively on chmod'ed sockets bridged by one of the layer 1 daemons. Layers 3+ inherit from layer 2 in a similar fashion. The two lines giving me grief are commented out at the very bottom of the *filter rules. The first line runs fine but it's all or nothing. :) Many thanks, Peter H. *nat #Flush previous rules, chains and counters for the 'nat' table -F -X -Z #Redirect traffic to alternate internal ports -I PREROUTING --src 0/0 -p tcp --dport 80 -j REDIRECT --to-ports 8080 -I PREROUTING --src 0/0 -p tcp --dport 443 -j REDIRECT --to-ports 8443 -I PREROUTING --src 0/0 -p udp --dport 53 -j REDIRECT --to-ports 8053 -I PREROUTING --src 0/0 -p tcp --dport 9022 -j REDIRECT --to-ports 8022 COMMIT *filter #Flush previous settings, chains and counters for the 'filter' table -F -X -Z #Set default behavior for all connections and protocols -P INPUT DROP -P OUTPUT DROP -A FORWARD -j DROP #Only accept loopback traffic originating from the local NIC -A INPUT -i lo -j ACCEPT -A INPUT ! -i lo -d 127.0.0.0/8 -j DROP #Accept all outgoing non-fragmented traffic having a valid state -A OUTPUT ! -f -m state --state NEW,RELATED,ESTABLISHED -j ACCEPT #Drop fragmented incoming packets (Not always malicious - acceptable for use now) -A INPUT -f -j DROP #Allow ping requests rate limited to one per second (burst ensures reliable results for high latency connections) -A INPUT -p icmp --icmp-type 8 -m limit --limit 1/sec --limit-burst 2 -j ACCEPT #Declaration of custom chains -N INSPECT_TCP_FLAGS -N INSPECT_STATE -N INSPECT #Drop incoming tcp connections with invalid tcp-flags -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ALL ALL -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ALL NONE -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ACK,FIN FIN -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ACK,PSH PSH -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ACK,URG URG -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags SYN,FIN SYN,FIN -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ALL FIN,PSH,URG -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags FIN,RST FIN,RST -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags SYN,RST SYN,RST -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ALL SYN,FIN,PSH,URG -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ALL SYN,RST,ACK,FIN,URG -j DROP #Accept incoming traffic having either an established or related state -A INSPECT_STATE -m state --state ESTABLISHED,RELATED -j ACCEPT #Drop new incoming tcp connections if they aren't SYN packets -A INSPECT_STATE -m state --state NEW -p tcp ! --syn -j DROP #Drop incoming traffic with invalid states -A INSPECT_STATE -m state --state INVALID -j DROP #INSPECT chain definition -A INSPECT -p tcp -j INSPECT_TCP_FLAGS -A INSPECT -j INSPECT_STATE #Route incoming traffic through the INSPECT chain -A INPUT -j INSPECT #Accept redirected HTTP traffic via HA reverse proxy -A INPUT -p tcp --dport 8080 -j ACCEPT #Accept redirected HTTPS traffic via STUNNEL SSH gateway (As well as tunneled HTTPS traffic destine for other services) -A INPUT -p tcp --dport 8443 -j ACCEPT #Accept redirected DNS traffic for NSD authoritative nameserver -A INPUT -p udp --dport 8053 -j ACCEPT #Accept redirected SSH traffic for OpenSSH server #Temp solution: -A INPUT -p tcp --dport 8022 -j ACCEPT #Ideal solution: #Limit new ssh connections to max 10 per 10 minutes while allowing an "unlimited" (or better reasonably limited?) number of established connections. #-A INPUT -p tcp --dport 8022 --state NEW,ESTABLISHED -m recent --set -j ACCEPT #-A INPUT -p tcp --dport 8022 --state NEW -m recent --update --seconds 600 --hitcount 11 -j DROP COMMIT *mangle #Flush previous rules, chains and counters in the 'mangle' table -F -X -Z COMMIT

    Read the article

  • EMC VNX iSCSI setup - unsure about SP/port assignment

    - by pauska
    We have a new VNX5300 waiting to get configured, and I need to plan out the network infrastructure before the EMC tech arrives. It has 4x1gbit iSCSI per SP (8 ports in total), and I'd like to get the most out of the performance until we jump over to 10gig iSCSI. From what I can read from the docs - the recommendation is to use only two ports per SP, with 1 active and 1 passive. Why is this? It seems kind of pointless to have quad-port i/o-modules and then recommend to not use more than two of them? Also - I'm a bit unsure about the zoning. The best practices guide state that you should separate each port on each SP from each other on different logical networks. Does this mean that I have to create 4 logical networks to be able to use all 8 ports? It also gives the following example: Does this mean that A0 and B0 should sit on the same physical switch aswell? Won't this make all traffic go on one switch (if both A1 and B1 are passive)? Edit: Another brainpuzzle I don't get it - each host (as in server) should not have more iSCSI bandwidth available than the storage processor. What on earth does this matter? If serverA have 1gbit and serverB have 100mbit, then the resulting bandwith between them is 100mbit. How can this result in some kind of oversubscription? Edit4: Wait, what. Active and passive ports? The VNX runs in a ALUA configuration with asymmetrical active/active.. there shouldn't be any passive ports, only preferred ones..

    Read the article

  • "Can't find root filesystem / error mounting /dev/root" when booting to new kernel

    - by salparadise
    I am trying to upgrade my kernel from 2.6.18-274 to 2.6.39 for some wireless card drivers. When I boot into the new kernel I get the "Can't find root filesystem / error mounting /dev/root" googling led me to this page http://fedoraproject.org/wiki/Common_kernel_problems#Can.27t_find_root_filesystem_.2F_error_mounting_.2Fdev.2Froot From what I am reading seems to be an issue with a driver for my SATA controller or HD, but I can't find what option I need to add to the kernel. Doing a diff from the old initrd to the new one gives me the following: root-> diff /tmp/kafter /tmp/kbefore 6a7,8 > lib/dm-message.ko > lib/dm-region_hash.ko 8a11 > lib/dm-raid45.ko 13d15 < lib/dm-region-hash.ko 16a19 > lib/dm-mem-cache.ko Do I need any of those? not sure if I would need dm-raid45.ko as I am not running a raid. I have the same SATA and IDE options configured for both kernels so not sure what else to look for, any help is appreciated. Additionally here is the HW info: 00:1f.2 IDE interface: Intel Corporation 82801FB/FW (ICH6/ICH6W) SATA Controller (rev 03) (prog-if 8f [Master SecP SecO PriP PriO]) Subsystem: Hewlett-Packard Company Unknown device 3006 Flags: bus master, 66MHz, medium devsel, latency 0, IRQ 233 I/O ports at 1818 [size=8] I/O ports at 1830 [size=4] I/O ports at 1820 [size=8] I/O ports at 1834 [size=4] I/O ports at 14f0 [size=16] Capabilities: [70] Power Management version 2 root-> smartctl -a /dev/sda ... === START OF INFORMATION SECTION === Device Model: WDC WD5000AADS-00S9B0

    Read the article

  • How to solve virtual host issue

    - by Webnet
    I have multiple sites all setup the same as below except "bk" has something else in it's place... NameVirtualHost *:80 <VirtualHost bk:80> ServerName bk DocumentRoot /var/www/bk.com/ </VirtualHost> and I get these errors when restarting apache: [Mon Jan 17 10:28:56 2011] [error] VirtualHost bk:80 -- mixing * ports and non-* ports with a NameVirtualHost address is not supported, proceeding with undefined results [Mon Jan 17 10:28:56 2011] [warn] NameVirtualHost bk:80 has no VirtualHosts I don't get it... the other 2 sites I have virtual host configurations for this exact same way don't throw any errors update One error message fixed - here's where I'm at now.. <VirtualHost bk:80> ServerName bk DocumentRoot /var/www/bk.com/ </VirtualHost> [Mon Jan 17 10:28:56 2011] [error] VirtualHost bk:80 -- mixing * ports and non-* ports with a NameVirtualHost address is not supported, proceeding with undefined results

    Read the article

  • Short, intermittent USB port timeouts

    - by jacobsee
    I have a data acquisition application controlled by a Windows PC. I am using an Intel Desktop Board DH67CL motherboard. This has 6 USB2 ports along with 2 of the new blue USB3 ports. The DAQ instrument connects via USB to the computer. Roughly once every day or two there is a short communication glitch with the USB that causes the instrument to disconnect briefly and then reconnect. This is logged so I know whenever it happens. Occasionally it will cause the data acquisition to stop. I've verified that the glitches will go away if I use the USB3 ports, or if I use a PCI add-on card with USB ports. So it seems that there is something going on with these built-in USB2 ports on this motherboard. I haven't yet had a chance to test with other motherboards. My question: what could be causing these glitches and how to get rid of them for this board, or is there a better motherboard to use? We have standardized on the DH67CL because it's inexpensive, has 3 PCI slots that we need, and is readily available. We don't need the power of higher-end server boards but reliability is important. Thanks. Update: This problem has been reproduced many times on different hardware, though we always use the same model of motherboard (DH67CL) and power supply (Antec EA-430D). I don't think the power requirements are very high but will check on that.

    Read the article

  • When can an FTP server close its passive connections?

    - by Don Kirkby
    Does the FTP protocol allow the server to close any of its passive connections while the client is still connected? Can it tell when the client is finished receiving and then close the connection? I'm including an FTP server in my application using the pyftpdlib Python project. I've got it to work in active and passive mode, but I'm a bit concerned about when it closes its passive connections. I've tried connecting to it with both FileZilla and the default ftp command in Ubuntu, and in both cases, I get a new passive port for every request. That is, if I sit in the root folder and type ls 10 times, I use up 10 ports. This means that I have to allocate a big block of passive ports for the FTP server to use so it won't run out. As soon as the client disconnects, the server releases all the passive connections associated with that client and those ports can be reused. However, a long-running connection could use up a lot of ports.

    Read the article

  • Port mirroring on multiple switches

    - by Matt
    So here is the deal, I have a server on switch A where port 3 is monitoring traffic for most of the ports on switch A. However I have other users on switch B that needs to have port 3 on switch A monitor as well. Is this possible? I have been reading about rspan but doesnt seem to work. Switch A: monitor session 1 source interface fast0/1 - 2 monitor session 1 source interface fast0/4 - 46 monitor session 1 destination interface fast0/3 (this works great for switch A, I need a solution to get switch B to also have some ports sent to port 3 on switch A for monitoring.) Onxx, All the traffic on switch A is fine, there will be about 10-15 ports on switch B that I need to send to fa0/3 on switch A as the destination. I have the switches connected with a ethernet cable with a trunk port on both switches on port 48 on switch B and A and port 47 on A connects to our sonicwall. So I am assuming they are daisy chained? What if I did the following: Switch A monitor session 1 source interface fast0/1 - 2 monitor session 1 source interface fast0/4 - 46 monitor session 1 destination interface fast0/3 Put all of the ports on vlan 10 because I made an rspan vlan 10 On switch B monitor the ports I need will say 1-10 monitor session 1 source interface fast0/1 - 10 monitor session 1 destination remote vlan 10 as a prerequisite I would have created vlan 10 as a rspan vlan on switch B. Switch A Monitor session 1 destination remote vlan 10 Would this work? By the way I am working with cisco catalyst 3560 switches.

    Read the article

  • switch OFF syn cookies

    - by Nick
    We have several servers they have public IP's, but work together (one is with Load Balancer, orther with Apache Web server, other with MySQL and so on. Most of the ports are fire-walled, so only "local" servers can be connect there. However ALL servers have some ports that must be publicly open. We have SYN Cookies enabled and from time to time we got: possible SYN flooding on port 8080. Sending cookies. Port 8080 is not public. How we can switch OFF SYN Cookies for some ports (e.g. 8080, 3306 etc) or from some sources (e.g. our servers), but in same time SYN Cookies to be switched ON for all other ports, e.g. port 80. We found this similar problem, except our servers are with public IP's: SYN cookies on internal machines

    Read the article

  • Why do people tell me not to use VLANs for security?

    - by jtnire
    Hi Everyone, As per title, why do people tell me not to use VLANs for security purposes? I have a network, where a have a couple of VLANS. There is a firewall between the 2 VLANs. I am using HP Procurve switches and have made sure that switch-to-switch links accept tagged frames only and that host ports don't accept tagged frames (They are not "VLAN Aware"). I've also made sure that the native VLAN (PVID) of the trunk links are not the same as either of the 2 host VLANs. I've also enabled "Ingress Filtering". Furthermore, I've made sure that host ports are only members of a single VLAN, which is the same as the PVID of the respective port. The only ports which are members of multiple VLANs are the trunk ports. Can someone please explain to me why the above isn't secure? I believe I've addressed the double tagging issue.. Thanks

    Read the article

  • Printer demands specific USB port

    - by snitzr
    My HP laptop has 3 USB ports. When I add my printer driver by plugging into one of those ports, the driver installs fine. Problem: I have to install 3 identical drivers. One for each USB port. Depending on what USB port I have the printer plugged into, I have to pick the driver for that port. Question: How do I print to any of the three ports automatically based on what port the printer is in? Further into: In Devices and Printers Printer Properties Ports... I cannot select more than one port for a printer driver to print to.

    Read the article

  • Proxy within a proxy, tunneling?

    - by joeblogger
    At work there is a proxy that (understandably) blocks all ports except web ones. However, during lunch hours you are allowed to play online games. But as ports are blocked, multiplayer games are out of the question. So I was wondering, could I set up a tunnel on a web port, that would then allow me to access those blocked ports, through the port 80 tunnel whilst still being behind the work proxy? This is in a Windows environment.

    Read the article

  • USB 3.0 port with USB 3.0 device in Ubuntu 12.10

    - by fernando garcía
    When I try to connect a USB 3.0 device in Ubuntu 12.10 (ASUS K55VD, kernel 3.5.0-19-generic #30-Ubuntu SMP), the system says [ 74.747832] hub 3-0:1.0: unable to enumerate USB device on port 1 [ 74.931957] usb 4-1: new SuperSpeed USB device number 2 using xhci_hcd [ 74.949390] usb 4-1: New USB device found, idVendor=05e3, idProduct=0731 [ 74.949396] usb 4-1: New USB device strings: Mfr=0, Product=1, SerialNumber=2 [ 74.949400] usb 4-1: Product: USB Storage [ 74.949403] usb 4-1: SerialNumber: 0000000000000033 [ 75.033327] usbcore: registered new interface driver uas [ 75.038548] Initializing USB Mass Storage driver... [ 75.038651] scsi7 : usb-storage 4-1:1.0 [ 75.038700] usbcore: registered new interface driver usb-storage [ 75.038701] USB Mass Storage support registered. but it does not recognize the device, and the disks applications (gparted, nautilus) act as if nothing had been connected. I have checked other questions, but either they have no answers or they told about previous Ubuntu version with 3.0.x kernels. A USB 2.0 device will work in the USB 3.0 ports. A USB 3.0 device will work (at USB 2.0 speeds) in the USB 2.0 ports. The problem, as I wrote, is between USB 3.0 devices and USB 3.0 ports. I have my USB 3.0 ports configured without legacy support via the BIOS (the way they should be, I suppose). But I also have tried to configure them with XHCI Preboot mode disabled. Have any one solved a similar problem? Thanks in advance.

    Read the article

  • M-Audio Delta 1010LT on 12.04

    - by user74039
    I have 12.04 64bit installed, my soundcard is a Delta 1010LT, it seems to be partially detected, I've been following steps here: https://help.ubuntu.com/community/SoundTroubleshooting/ lspci -v | grep -A7 -i "audio" shows this: 04:07.0 Multimedia audio controller: VIA Technologies Inc. ICE1712 [Envy24] PCI Multi-Channel I/O Controller (rev 02) Subsystem: VIA Technologies Inc. M-Audio Delta 1010LT Flags: bus master, medium devsel, latency 64, IRQ 22 I/O ports at ec00 [size=32] I/O ports at e880 [size=16] I/O ports at e800 [size=16] I/O ports at e480 [size=64] Capabilities: <access denied> Kernel driver in use: snd_ice1712 aplay shows this: **** List of PLAYBACK Hardware Devices **** card 0: M1010LT [M Audio Delta 1010LT], device 0: ICE1712 multi [ICE1712 multi] Subdevices: 1/1 Subdevice #0: subdevice #0 In the sound settings on the desktop all I see is the ICE1712 S/PDIF, which I don't use, I want to use the individual outputs on the card, I'm not so bothered about inputs, I just want the playback for now. If I open alsamixer in the console, I see all of the output and input channels, i've raised the volume on them but I don't get anything in the sound settings on the desktop and when I play any sound, I hear nothing. Can someone help?

    Read the article

  • VNIC - New feature of AK8 - Working with VNICs

    - by Steve Tunstall
    One of the important new features of the AK8 code is the ability to use multiple IP addresses on the same physical network port. This feature is called VNICs, or Virtual NICs. This allows us to no longer "burn" a whole port in a cluster when one cluster peer owns a network port. Traditionally, we have had to leave Net0 empty on controller 2, because it was used for managing controller 1. Vise-versa for Net1 on Controller 1. Then, if you have data going over 10GigE ports, you probably only had half of your ports running at any given time, and the partner 10GigE port on the other controller just sat there, doing nothing, unless the first controller went down. What a waste. Those days are over.  I want to thank and give a big shout-out to our good partner, OnX Enterprise Solutions, for allowing me to come into their lab and play around with their 7320 to do this demo. They let me make a big mess of their lab for the day as I played around with VNICs. If you're looking for a partner who knows Oracle well and can also piece together a solution from multiple vendors to get you what you need, OnX is a good choice. If you would like to talk to your local OnX rep, you can contact Scott Gill at [email protected] and he can point you in the right direction for your area.  Here we go: Here is what your Datalinks window looks like BEFORE you upgrade to AK8. Here's what the same screen looks like after you upgrade. See the new box? So here is my current network setup. I have my 4 physical interfaces setup each with an IP address. If I ping them, no problems.  So I can ping 180, 181, 251, and 252. However, if I try to ping 240, it does not work, as the 240 address is not being used by any of these interfaces, right?Let's change that. Here, I'm going to make a new Datalink by clicking the Datalink "Plus sign" button. I will check the VNIC box and tell it to use igb2, even though another interface is already using it. Now, I will create a new Interface, and choose "v_dl2" for it's datalink. My new network screen looks like this. A few things to take note of here. First, when I click the "igb2" device, it only highlights dl2 and int2. It does not highlight v_dl2 or v_int2.I think it should, but OK, it looks like VNICs don't highlight when you click the device. Second, note how the underscore character in v_dl2 and v_int2 do not seem to show on this screen. You can see it plainly if you go in and edit them, but from here it looks like a space instead of an underscore. Just a cosmetic bug, but something to be aware of. Now, if I click the VNIC datalink "v_dl2", on the other hand, it DOES highlight the device it belongs to, as it should. Seen here: Note that it did not, however, highlight int2 with it, even though int2 is connected to igb2. That's because we clicked v_dl2, which int2 has nothing to do with. So I'm OK with that. So let's try pinging 240 now. Of course, it works great.  So I now make another VNIC, and call it v_dl3 using igb3, and v_int3 with an address of 241. I then setup three shares, using ports 251, 240, and 241.Remember that IP 251 and 240 both are using the same physical port of igb2, and IP 241 is using port igb3. Next, I copy a folder full of stuff over to all three shares at the same time. I have analytics going so I can see the traffic. My top chart is showing the logical interfaces, and the bottom chart is showing the physical ports.Sure enough, look at the igb2 and vnic1 interfaces. They equal the traffic going over the igb2 physical port on the second chart. VNIC2, on the other hand, gets igb3 all to itself. This would work the same way with 10Gig or Infiniband ports. You can now have multiple IP addresses and even completely different subnets sharing the same physical ports. You may need to make route table entries for that. This allows us to use all of the ports you paid for with no more waste.  Very, very cool.  One small "bug" I found when doing this. It's really not a bug, it was designed to do this when VNICs were not around. But now that we have NVIC capability, they should probably change this. I've alerted the engineering team about this and they're looking into it, so perhaps it will be fixed in a later code. Here it is. Remember when we made the new VNIC datalink, I specifically said to click on the "Plus Sign" button to create it? I don't always do that. I really like to use the drag-and-drop method to create my datalinks in the network screen.HOWEVER, if you were to do that for building a VNIC, it will mess you up a little. Watch this. Here, I'm dragging igb3 over to make a new datalink. igb3 is already being used by dl3, but I'm going to make this a VNIC, so who cares, right? Well, the ZFSSA does not KNOW you are going to make it a VNIC, now does it? So... it works as designed and REMOVES the igb3 device from the current dl3 datalink in the background. See how it's now missing? At the same time, the dl3 datalink choice is missing from my list of possible VNICs for me to choose from!!!! Hey!!! I wanted to pick dl3. Why isn't it on the list??? Well, it can't be on this list because dl3 no longer has a device associated with it. Bummer for you. When you click cancel, the device is still missing from dl3. The fix is easy. Just edit dl3 by clicking the pencil button, do absolutely nothing, and click "Apply". The device will magically come back. Now, make the VNIC datalink by clicking the "Plus Sign" button. Sure enough, once you check the VNIC box, dl3 is a valid choice. No problem.  That's it for now. Have fun with VNICs.

    Read the article

  • Problem mounting USB Mobile Broadband dongle in Ubuntu 13.04

    - by Still A Learner
    I have been using Ubuntu 13.04 since last two months and I have problem mounting my USB dongle. I have Lenovo G-580 series laptop. It has 3 USB ports which are 3.0. When I attach dongle to one of the three USB ports the device gets mounted immediately but in the other two ports I have to reboot the OS while the dongle is attached to the laptop in order to mount it and connect to the internet. My dongle is of ZTE. I don't get what is going wrong.

    Read the article

< Previous Page | 26 27 28 29 30 31 32 33 34 35 36 37  | Next Page >