Search Results

Search found 8166 results on 327 pages for 'seven year liberal arts degree'.

Page 314/327 | < Previous Page | 310 311 312 313 314 315 316 317 318 319 320 321  | Next Page >

  • php functions within functions.

    - by Adamski
    Hi all, ihave created a simple project to help me get to grips with php and mysql, but have run into a minor issue, i have a working solution but would like to understand why i cannot run this code successfully this way, ill explain: i have a function, function fetch_all_movies(){ global $connection; $query = 'select distinct * FROM `'.TABLE_MOVIE.'` ORDER BY movieName ASC'; $stmt = mysqli_prepare($connection,$query); mysqli_execute($stmt); mysqli_stmt_bind_result($stmt,$id,$name,$genre,$date,$year); while(mysqli_stmt_fetch($stmt)){ $editUrl = "index.php?a=editMovie&movieId=".$id.""; $delUrl = "index.php?a=delMovie&movieId=".$id.""; echo "<tr><td>".$id."</td><td>".$name."</td><td>".$date."</td><td>".get_actors($id)."</td><td><a href=\"".$editUrl."\">Edit</a> | <a href=\"".$delUrl."\">Delete</a></td></tr>"; } } this fetches all the movies in my db, then i wish to get the count of actors for each film, so i pass in the get_actors($id) function which gets the movie id and then gives me the count of how many actors are realted to a film. here is the function for that: function get_actors($movieId){ global $connection; $query = 'SELECT DISTINCT COUNT(*) FROM `'.TABLE_ACTORS.'` WHERE movieId = "'.$movieId.'"'; $result = mysqli_query($connection,$query); $row = mysqli_fetch_array($result); return $row[0]; } the functions both work perfect when called separately, i just would like to understand when i pass the function inside a function i get this warning: Warning: mysqli_fetch_array() expects parameter 1 to be mysqli_result, boolean given in /Applications/MAMP/htdocs/movie_db/includes/functions.inc.php on line 287 could anyone help me understand why? many thanks.

    Read the article

  • C++ vector of strings, pointers to functions, and the resulting frustration.

    - by Kyle
    So I am a first year computer science student, for on of my final projects, I need to write a program that takes a vector of strings, and applies various functions to these. Unfortunately, I am really confused on how to use pointer to pass the vector from function to function. Below is some sample code to give an idea of what I am talking about. I also get an error message when I try to deference any pointer. thanks. #include <iostream> #include <cstdlib> #include <vector> #include <string> using namespace std; vector<string>::pointer function_1(vector<string>::pointer ptr); void function_2(vector<string>::pointer ptr); int main() { vector<string>::pointer ptr; vector<string> svector; ptr = &svector[0]; function_1(ptr); function_2(ptr); } vector<string>::pointer function_1(vector<string>::pointer ptr) { string line; for(int i = 0; i < 10; i++) { cout << "enter some input ! \n"; // i need to be able to pass a reference of the vector getline(cin, line); // through various functions, and have the results *ptr.pushback(line); // reflectedin main(). But I cannot use member functions } // of vector with a deferenced pointer. return(ptr); } void function_2(vector<string>::pointer ptr) { for(int i = 0; i < 10; i++) { cout << *ptr[i] << endl; } }

    Read the article

  • Suggest an alternative way to organize/build a database solution.

    - by Hamish Grubijan
    We are using Visual Studio 2010, but this was first conceived with VS2003. I will forward the best suggestions to my team. The current setup almost makes me vomit. It is a C# solution with most projects containing .sql files. Because we support Microsoft, Oracle, and Sybase, and so home-brewed a pre-processor, much like C preprocessor, except that substitutions are performed by a home-brewed C# program without using yacc and tools like that. #ifdefs are used for conditional macro definitions, and yeah - macros are the way this is done. A macro can expand to another macro or two, but this should eventually terminate. Only macros have #ifdef in them - the rest of the SQL-like code just uses these macros. Now, the various configurations: Debug, MNDebug, MNRelease, Release, SQL_APPLY_ALL, SQL_APPLY_MSFT, SQL_APPLY_ORACLE, SQL_APPLY_SYBASE, SQL_BUILD_OUTPUT_ALL, SQL_COMPILE, as well as 2 more. Also: Any CPU, Mixed Platforms, Win32. What drives me nuts is having to configure it correctly as well as choosing the right one out of 12 x 3 = 36 configurations as well as having to substitute database name depending on the type of database: config, main, or gateway. I am thinking that configuration should be reduced to just Debug, Release, and SQL_APPLY. Also, using 0, 1, and 2 seems so 80s ... Finally, I think my intention to build or not to build 3 types of databases for 3 types of vendors should be configured with just a tic tac toe board like: XOX OOX XXX In this case it would mean build MSFT+CONFIG, all SYBASE, and all GATEWAY. Still, the overall thing which uses a text file and a pre-processor and many configurations seems incredibly clunky. It is year 2010 now and someone out there is bound to have a very clean and/or creative tool/solution. The only pro would be that the existing collection of macros has been well tested. Have you ever had to write SQL that would work for several vendors? How did you do it? SqlVars.txt (Every one of 30 users makes a copy of a template and modifies this to suit their needs): // This is the default parameters file and should not be changed. // You can overwrite any of these parameters by copying the appropriate // section to override into SqlVars.txt and providing your own information. //Build types are 0-Config, 1-Main, 2-Gateway BUILD_TYPE=1 REMOVE_COMMENTS=1 // Login information used when applying to a Microsoft SQL server database SQL_APPLY_MSFT_version=SQL2005 SQL_APPLY_MSFT_database=msftdb SQL_APPLY_MSFT_server=ABC SQL_APPLY_MSFT_user=msftusr SQL_APPLY_MSFT_password=msftpwd // Login information used when applying to an Oracle database SQL_APPLY_ORACLE_version=ORACLE10g SQL_APPLY_ORACLE_server=oradb SQL_APPLY_ORACLE_user=orausr SQL_APPLY_ORACLE_password=orapwd // Login information used when applying to a Sybase database SQL_APPLY_SYBASE_version=SYBASE125 SQL_APPLY_SYBASE_database=sybdb SQL_APPLY_SYBASE_server=sybdb SQL_APPLY_SYBASE_user=sybusr SQL_APPLY_SYBASE_password=sybpwd ... (THIS GOES ON)

    Read the article

  • Finding open contiguous blocks of time for every day of a month, fast

    - by Chris
    I am working on a booking availability system for a group of several venues, and am having a hard time generating the availability of time blocks for days in a given month. This is happening server-side in PHP, but the concept itself is language agnostic -- I could be doing this in JS or anything else. Given a venue_id, month, and year (6/2012 for example), I have a list of all events occurring in that range at that venue, represented as unix timestamps start and end. This data comes from the database. I need to establish what, if any, contiguous block of time of a minimum length (different per venue) exist on each day. For example, on 6/1 I have an event between 2:00pm and 7:00pm. The minimum time is 5 hours, so there's a block open there from 9am - 2pm and another between 7pm and 12pm. This would continue for the 2nd, 3rd, etc... every day of June. Some (most) of the days have nothing happening at all, some have 1 - 3 events. The solution I came up with works, but it also takes waaaay too long to generate the data. Basically, I loop every day of the month and create an array of timestamps for each 15 minutes of that day. Then, I loop the time spans of events from that day by 15 minutes, marking any "taken" timeslot as false. Remaining, I have an array that contains timestamp of free time vs. taken time: //one day's array after processing through loops (not real timestamps) array( 12345678=>12345678, // <--- avail 12345878=>12345878, 12346078=>12346078, 12346278=>false, // <--- not avail 12346478=>false, 12346678=>false, 12346878=>false, 12347078=>12347078, // <--- avail 12347278=>12347278 ) Now I would need to loop THIS array to find continuous time blocks, then check to see if they are long enough (each venue has a minimum), and if so then establish the descriptive text for their start and end (i.e. 9am - 2pm). WHEW! By the time all this looping is done, the user has grown bored and wandered off to Youtube to watch videos of puppies; it takes ages to so examine 30 or so days. Is there a faster way to solve this issue? To summarize the problem, given time ranges t1 and t2 on day d, how can I determine the remaining time left in d that is longer than the minimum time block m. This data is assembled on demand via AJAX as the user moves between calendar months. Results are cached per-page-load, so if the user goes to July a second time, the data that was generated the first time would be reused. Any other details that would help, let me know. Edit Per request, the database structure (or the part that is relevant here) *events* id (bigint) title (varchar) *event_times* id (bigint) event_id (bigint) venue_id (bigint) start (bigint) end (bigint) *venues* id (bigint) name (varchar) min_block (int) min_start (varchar) max_start (varchar)

    Read the article

  • How to reference a particular JSON in a function call.

    - by Jane Wilkie
    Hi guys! I have two javascript routines.. the first one declares some JSON and it contains a function that takes two arguments, the first argument being the json object that needs traversing and the second argument is the tab that the rendering is done in. The second routine merely passes the name of the JSON that needs traversing and tab to render in. The code is below.... <script language="JavaScript1.2" type="text/javascript"> var arr = [ {"id":"10", "class":"child-of-9", "useless":"donotneed"}, {"id":"11", "class":"child-of-10", "useless":"donotneed"}]; var arrtwo = [ {"id":"12", "class":"child-of-12", "useless":"donotneed"}, {"id":"13", "class":"child-of-13", "useless":"donotneed"}]; function render_help(json,tab){ var html=''; for(var i=0;i<json.length;i++){ var obj = json[i]; for(var key in obj){ var attrName = key; var attrValue = obj[key]; if (attrName == "id"){ html = html +'<B>'+attrValue+'</B>'+'<BR><BR>'; }else if (attrName == "class"){ html = html + attrValue + '<BR><BR>'; } } } document.getElementById(tab).innerHTML=(html); } </script> <script language="JavaScript1.2" type="text/javascript"> render_help(arr,"helptab"); </script> Various testing and strategically placed alert boxes indicate that the tab parameter is being passed and interpreted correctly. I know this because when I change .... document.getElementById(tab).innerHTML=(html); to document.getElementById(tab).innerHTML=("Howdy"); and it renders "Howdy" just fine. Putting an alert box (alert(json)) in to check the value of json yields.... [object.Object],[object.Object] The JSON object remains elusive. For the purposes of this scripting I need the JSON "arr" to be iterated over. I feel like the answer is fairly obvious so far no luck. Admittedly I am new with Javascript and I am apparently missing something. Does anyone have a clue as to what I'm overlooking here? Happy New Year to you all! Janie

    Read the article

  • Drag and drop game - why isn't it working now I've moved it to another domain?

    - by vward
    Earlier this year I did some work on a drag and drop game. It was the first thing I'd coded other than basic html. I got it working but then had to put it to one side for a while. I've now come back to work on it. The game I had created was put on the ftp of a domain I no longer have. I took the html and image files and put them on another domain expecting them to work. However now nothing drags! I don't know what could be different. I can barely remember how I coded this in the first place. Is there an additional file that should be on the ftp or something like that? Can anyone shed any light? Thanks Vic Game: http://www.vic-taylor.com/dolls/doll6.html Code: <!doctype html> <html lang="en"> <head> <script src="http://code.jquery.com/jquery.min.js"></script> <script src="http://code.jquery.com/ui/1.8.17/jquery-ui.min.js"></script> <script> $(function() { $( "#draggable" ).draggable() }); </script> <script> $(function() { $( "#draggable2" ).draggable(); }); </script> <script> $(function() { $( "#draggable3" ).draggable(); }); </script> <script> $(function() { $( "#draggable4" ).draggable(); }); </script> <script> $(function() { $( "#draggable5" ).draggable(); }); </script> </head> </body> <div id="bodies/palepd.gif"> <img src="bodies/palepd.gif" class="ui-widget-content" id="draggable"> <img src="bodies/trousers.gif" class="ui-widget-content" id="draggable2"> <img src="bodies/top.gif" class="ui-widget-content" id="draggable3"> <img src="bodies/dress.gif" class="ui-widget-content" id="draggable4"> <img src="bodies/coat.gif" class="ui-widget-content" id="draggable5"> </div> </body>

    Read the article

  • Which MS technologies would be suited for a data intensive application?

    - by steve.tse
    I'm a junior VB.net developer with little application design knowledge. I've been reading a lot of material online regarding different design patterns, frameworks, and methodologies. It's become a bit confusing for me. Right now I'm trying to decide on what language would be best suited to convert an existing VB6 application (with SQL server backend.) I need to update the UI and add more user functionality and reporting capabilities. Initially I was thinking of using WPF and attempting the MVVM model for this big project. Reports would be generated from SSRS. A peer suggested using ASP.net and I don't have enough experience to determine what would be better. The senior programmers here are stuck on using VB6 and don't have any input on what to use. They are encouraging me to use the latest technologies. This application would be for ~20 users in a central location. Ideally I would stick to a Microsoft .net language. Current interface is similar to a datagrid table where the user would click in to see the detail of each record. They would need to have multiple records open at any given time. I look forward to all the advice I can get. EDIT 2010/04/22 2:47 PM EST What is your audience? Internal clients within an intranet How complex are the interactions you expect to implement? not very... displaying data from SQL server to UI. Allow user updates to said data. Typically just one user modifying a record. Do you require near real-time data updates? no How often do you expect to update the application after the first release? twice/year Do you expect a well-defined set of client platforms? Yes, windows xp environment, potentially upgrading to Win7. Currently in IE.6 moving to IE7 or 8 within a couple of months. Do users need access from anywhere? No, just from their PC.

    Read the article

  • Adding a clustered index to a SQL table: what dangers exist for a live production system?

    - by MoSlo
    Right, keep in mind i need to describe this by abstracting all possible confidential info: I've been put in charge of a 10-year old transactional system of which the majority business logic is implemented at database level (triggers, stored procedures etc). Win2000 server, MSSQL 2000 Enterprise. No immediate plans for replacing/updating the system are being considered :( The core process is a program that executes transactions - specifically, it executes a stored procedure with various parameters, lets call it sp_ProcessTrans. The program executes the stored procedure at asynchronous intervals. By itself, things work fine. But there are 30 instances of this program on remotely located workstations, all of them asynchronously executing sp_ProcessTrans and then retrieving data from the SQL server (execution is pretty regular - ranging 0 to 60 times a minute, depending on what items the program instance is responsible for) . Performance of the system has dropped considerably with 10 yrs of data growth: the reason is the deadlocks and specifically deadlock wait times. The deadlock is on the Employee table. I have discovered: In sp_ProcessTrans' execution, it selects from an Employee table 7 times (dont ask) The select is done on a field that is NOT the primary key No index exists on this field. Thus a table scan is performed. 7 times. per transaction So the reason for deadlocks is clear. I created a non-unique ordered clustered index on the field (field looks good, almost unique, NUM(7), very rarely changes). Immediate improvement in the test environment. The problem is that i cannot simulate the deadlocks in a test environment (I'd need 30 workstations; i'd need to simulate 'realistic' activity on those stations, so visualization is out). I need to know if i must schedule downtime. Creating an index shouldn't be a risky operation for MSSQL, but is there any danger (data corruption in transactions/select statements/extra wait time etc) to create this field index on the production database while the transactions are still taking place? (although i can select a time when transactions are fairly quiet through the 30 stations) Are there any hidden dangers i'm not seeing (not looking forward to needing to restore the DB if something goes wrong, restoring would take a lot of time with 10yrs of data).

    Read the article

  • Sorting a list of numbers with modified cost

    - by David
    First, this was one of the four problems we had to solve in a project last year and I couldn’t find a suitable algorithm so we handle in a brute force solution. Problem: The numbers are in a list that is not sorted and supports only one type of operation. The operation is defined as follows: Given a position i and a position j the operation moves the number at position i to position j without altering the relative order of the other numbers. If i j, the positions of the numbers between positions j and i - 1 increment by 1, otherwise if i < j the positions of the numbers between positions i+1 and j decreases by 1. This operation requires i steps to find a number to move and j steps to locate the position to which you want to move it. Then the number of steps required to move a number of position i to position j is i+j. We need to design an algorithm that given a list of numbers, determine the optimal (in terms of cost) sequence of moves to rearrange the sequence. Attempts: Part of our investigation was around NP-Completeness, we make it a decision problem and try to find a suitable transformation to any of the problems listed in Garey and Johnson’s book: Computers and Intractability with no results. There is also no direct reference (from our point of view) to this kind of variation in Donald E. Knuth’s book: The art of Computer Programing Vol. 3 Sorting and Searching. We also analyzed algorithms to sort linked lists but none of them gives a good idea to find de optimal sequence of movements. Note that the idea is not to find an algorithm that orders the sequence, but one to tell me the optimal sequence of movements in terms of cost that organizes the sequence, you can make a copy and sort it to analyze the final position of the elements if you want, in fact we may assume that the list contains the numbers from 1 to n, so we know where we want to put each number, we are just concerned with minimizing the total cost of the steps. We tested several greedy approaches but all of them failed, divide and conquer sorting algorithms can’t be used because they swap with no cost portions of the list and our dynamic programing approaches had to consider many cases. The brute force recursive algorithm takes all the possible combinations of movements from i to j and then again all the possible moments of the rest of the element’s, at the end it returns the sequence with less total cost that sorted the list, as you can imagine the cost of this algorithm is brutal and makes it impracticable for more than 8 elements. Our observations: n movements is not necessarily cheaper than n+1 movements (unlike swaps in arrays that are O(1)). There are basically two ways of moving one element from position i to j: one is to move it directly and the other is to move other elements around i in a way that it reaches the position j. At most you make n-1 movements (the untouched element reaches its position alone). If it is the optimal sequence of movements then you didn’t move the same element twice.

    Read the article

  • A versioning workflow for multiple similar (but not identical) deployments

    - by rs77
    I'm currently employed at a small non-tech organisation and have been given the role of coding the organisations' website. While I have enjoyed the task and have learnt much with web dev I've encountered a few issues that I'm hoping someone will be able to help with me or at least point me in the right direction on. A little background: The site I work on has subdomains that each have their own separate WordPress installation on - as this has been the easiest "backend" admin panel for the type of user who will be responsible for updating content (etc). Within the organisation I work under the Marketing Manager (MM) and I code according to his style guide and wire frames. While we have been working with only one subdomain since the beginning of the year the project has been relatively simple and straightforward. However, lately the workflow is becoming a little more complicated as our original subdomain has been copied over to the other subdomains. Each of the new subdomains receives minor edits to their stylesheets (eg. different pictures for background, slightly different colours here and there, etc). The issue: At the moment managing all the different subdomains has been "bearable", but the straw that's braking the camel's back at the moment has been the slight reversions the MM has required now that the CEO has seen the final product. The problem I'm having with reversions in stylesheets is that the CEO will one week state that he likes change "X" and then as the MM and I continue to modify the site (to now "Z"), will another week state that he wants us to change "X" to "W" but keeping most of the changes made in "Y". What I'm looking for is something that allows for: tracking file changes reverting changes made (or reverting back to 'a' from 'e' but including changes 'b' & 'c') easily upload necessary files to their respective WP-theme installation Does anything out there come close to addressing these issues? If so, what? Thanks for any help! PS - I'm learning Git at the moment and it seems to do the "tracking file changes" quite nicely. Haven't learnt about the reverting changes bit yet, though. Maybe for my final point I'm thinking of creating a shell script to automatically upload the files to their folders. Does Git do this too though? Addendum (alexbbrown) I had a similar problem: I ran a custom version of mediawiki where I installed various extensions in the versioned core (with svn). Each of the extensions required an section in the confit file, but the confit file also needed local configuration for each of several deployments. I could have implemented it using includes, but they would not be versioned; and rebasing branches each time is a chore. +50 experience points for a good answer in git.

    Read the article

  • Form Search Onkeyup event

    - by Aryan
    I Have a Form In which the form should automatically search when i complete entering the 10th character in the text field but the below code is searching for each n every character i enter in the text field . . . I just want the result after completing the 10th character not for each n every character . . i have used onkeyup event and i set that value to 10 but still it is searching for each n every character... please do help me <body OnKeyPress="return disableKeyPress(event)"> <section id="content" class="container_12 clearfix" data-sort=true> <center><table class='dynamic styled with-prev-next' data-table-tools='{'display':true}' align=center> <script> function disableEnterKey(e) { var key; if(window.event) key = window.event.keyCode; //IE else key = e.which; //firefox return (key != 13); } function showUser(str) { if (str=="") { document.getElementById("txtHint").innerHTML=""; return; } if (window.XMLHttpRequest) {// code for IE7+, Firefox, Chrome, Opera, Safari xmlhttp=new XMLHttpRequest(); } else {// code for IE6, IE5 xmlhttp=new ActiveXObject("Microsoft.XMLHTTP"); } xmlhttp.onreadystatechange=function() { if (xmlhttp.readyState==4 && xmlhttp.status==200) { document.getElementById("txtHint").innerHTML=xmlhttp.responseText; } } xmlhttp.open("GET","resdb.php?id="+str,true); xmlhttp.send(); } </script> <script type='text/javascript'> //<![CDATA[ $(window).load(function(){ $('#id').keyup(function(){ if(this.value.length ==10) }); });//]]> </script> <form id="form" method="post" name="form" > <tr><td><p align="center"><font size="3"><b>JNTUH - B.Tech IV Year II Semester (R07) Advance Supplementary Results - July 2012</b></font></p></td></tr> <td><p align="center"><b>Last Date for RC/RV : 8th August 2012</b></p></td> <tr><td><p align="center"></b> <input type="text" onkeyup="showUser(this.value)" onKeyPress="return disableEnterKey(event)" data-type="autocomplete" data-source="extras/autocomplete1.php" name="id" id="id" maxlength="10" placeholder=" Hall-Ticket Number">&emsp;</p></td></tr> </table> </center> </form> <center> <div id="txtHint"><b>Results will be displayed here</b></div> </center> </body>

    Read the article

  • How to auto-generate early bound properties for Entity specific (ie Local) Option Set text values?

    - by Daryl
    After spending a year working with the Microsoft.Xrm.Sdk namespace, I just discovered yesterday the Entity.FormattedValues property contains the text value for Entity specific (ie Local) Option Set texts. The reason I didn't discover it before, is there is no early bound method of getting the value. i.e. entity.new_myOptionSet is of type OptionSetValue which only contains the int value. You have to call entity.FormattedValues["new_myoptionset"] to get the string text value of the OptionSetValue. Therefore, I'd like to get the crmsrvcutil to auto-generate a text property for local option sets. i.e. Along with Entity.new_myOptionSet being generated as it currently does, Entity.new_myOptionSetText would be generated as well. I've looked into the Microsoft.Crm.Services.Utility.ICodeGenerationService, but that looks like it is mostly for specifying what CodeGenerationType something should be... Is there a way supported way using CrmServiceUtil to add these properties, or am I better off writing a custom app that I can run that can generate these properties as a partial class to the auto-generated ones? Edit - Example of the code that I would like to be generated Currently, whenever I need to access the text value of a OptionSetValue, I use this code: var textValue = OptionSetCache.GetText(service, entity, e => e.New_MyOptionSet); The option set cache will use the entity.LogicalName, and the property expression to determine the name of the option set that I'm asking for. It will then query the SDK using the RetrieveAttriubteRequest, to get a list of the option set int and text values, which it then caches so it doesn't have to hit CRM again. It then looks up the int value of the New_MyOptionSet of the entity and cross references it with the cached list, to get the text value of the OptionSet. Instead of doing all of that, I can just do this (assuming that the entity has been retrieved from the server, and not just populated client side): var textValue = entity.FormattedValues["new_myoptionset"]; but the "new_myoptionset" is no longer early bound. I would like the early bound entity classes that gets generated to also generate an extra "Text" property for OptionSetValue properties that calls the above line, so my entity would have this added to it: public string New_MyOptionSetText { return this.GetFormattedAttributeValue("new_myoptionset"); // this is a protected method on the Entity class itself... }

    Read the article

  • New features of C# 4.0

    This article covers New features of C# 4.0. Article has been divided into below sections. Introduction. Dynamic Lookup. Named and Optional Arguments. Features for COM interop. Variance. Relationship with Visual Basic. Resources. Other interested readings… 22 New Features of Visual Studio 2008 for .NET Professionals 50 New Features of SQL Server 2008 IIS 7.0 New features Introduction It is now close to a year since Microsoft Visual C# 3.0 shipped as part of Visual Studio 2008. In the VS Managed Languages team we are hard at work on creating the next version of the language (with the unsurprising working title of C# 4.0), and this document is a first public description of the planned language features as we currently see them. Please be advised that all this is in early stages of production and is subject to change. Part of the reason for sharing our plans in public so early is precisely to get the kind of feedback that will cause us to improve the final product before it rolls out. Simultaneously with the publication of this whitepaper, a first public CTP (community technology preview) of Visual Studio 2010 is going out as a Virtual PC image for everyone to try. Please use it to play and experiment with the features, and let us know of any thoughts you have. We ask for your understanding and patience working with very early bits, where especially new or newly implemented features do not have the quality or stability of a final product. The aim of the CTP is not to give you a productive work environment but to give you the best possible impression of what we are working on for the next release. The CTP contains a number of walkthroughs, some of which highlight the new language features of C# 4.0. Those are excellent for getting a hands-on guided tour through the details of some common scenarios for the features. You may consider this whitepaper a companion document to these walkthroughs, complementing them with a focus on the overall language features and how they work, as opposed to the specifics of the concrete scenarios. C# 4.0 The major theme for C# 4.0 is dynamic programming. Increasingly, objects are “dynamic” in the sense that their structure and behavior is not captured by a static type, or at least not one that the compiler knows about when compiling your program. Some examples include a. objects from dynamic programming languages, such as Python or Ruby b. COM objects accessed through IDispatch c. ordinary .NET types accessed through reflection d. objects with changing structure, such as HTML DOM objects While C# remains a statically typed language, we aim to vastly improve the interaction with such objects. A secondary theme is co-evolution with Visual Basic. Going forward we will aim to maintain the individual character of each language, but at the same time important new features should be introduced in both languages at the same time. They should be differentiated more by style and feel than by feature set. The new features in C# 4.0 fall into four groups: Dynamic lookup Dynamic lookup allows you to write method, operator and indexer calls, property and field accesses, and even object invocations which bypass the C# static type checking and instead gets resolved at runtime. Named and optional parameters Parameters in C# can now be specified as optional by providing a default value for them in a member declaration. When the member is invoked, optional arguments can be omitted. Furthermore, any argument can be passed by parameter name instead of position. COM specific interop features Dynamic lookup as well as named and optional parameters both help making programming against COM less painful than today. On top of that, however, we are adding a number of other small features that further improve the interop experience. Variance It used to be that an IEnumerable<string> wasn’t an IEnumerable<object>. Now it is – C# embraces type safe “co-and contravariance” and common BCL types are updated to take advantage of that. Dynamic Lookup Dynamic lookup allows you a unified approach to invoking things dynamically. With dynamic lookup, when you have an object in your hand you do not need to worry about whether it comes from COM, IronPython, the HTML DOM or reflection; you just apply operations to it and leave it to the runtime to figure out what exactly those operations mean for that particular object. This affords you enormous flexibility, and can greatly simplify your code, but it does come with a significant drawback: Static typing is not maintained for these operations. A dynamic object is assumed at compile time to support any operation, and only at runtime will you get an error if it wasn’t so. Oftentimes this will be no loss, because the object wouldn’t have a static type anyway, in other cases it is a tradeoff between brevity and safety. In order to facilitate this tradeoff, it is a design goal of C# to allow you to opt in or opt out of dynamic behavior on every single call. The dynamic type C# 4.0 introduces a new static type called dynamic. When you have an object of type dynamic you can “do things to it” that are resolved only at runtime: dynamic d = GetDynamicObject(…); d.M(7); The C# compiler allows you to call a method with any name and any arguments on d because it is of type dynamic. At runtime the actual object that d refers to will be examined to determine what it means to “call M with an int” on it. The type dynamic can be thought of as a special version of the type object, which signals that the object can be used dynamically. It is easy to opt in or out of dynamic behavior: any object can be implicitly converted to dynamic, “suspending belief” until runtime. Conversely, there is an “assignment conversion” from dynamic to any other type, which allows implicit conversion in assignment-like constructs: dynamic d = 7; // implicit conversion int i = d; // assignment conversion Dynamic operations Not only method calls, but also field and property accesses, indexer and operator calls and even delegate invocations can be dispatched dynamically: dynamic d = GetDynamicObject(…); d.M(7); // calling methods d.f = d.P; // getting and settings fields and properties d[“one”] = d[“two”]; // getting and setting thorugh indexers int i = d + 3; // calling operators string s = d(5,7); // invoking as a delegate The role of the C# compiler here is simply to package up the necessary information about “what is being done to d”, so that the runtime can pick it up and determine what the exact meaning of it is given an actual object d. Think of it as deferring part of the compiler’s job to runtime. The result of any dynamic operation is itself of type dynamic. Runtime lookup At runtime a dynamic operation is dispatched according to the nature of its target object d: COM objects If d is a COM object, the operation is dispatched dynamically through COM IDispatch. This allows calling to COM types that don’t have a Primary Interop Assembly (PIA), and relying on COM features that don’t have a counterpart in C#, such as indexed properties and default properties. Dynamic objects If d implements the interface IDynamicObject d itself is asked to perform the operation. Thus by implementing IDynamicObject a type can completely redefine the meaning of dynamic operations. This is used intensively by dynamic languages such as IronPython and IronRuby to implement their own dynamic object models. It will also be used by APIs, e.g. by the HTML DOM to allow direct access to the object’s properties using property syntax. Plain objects Otherwise d is a standard .NET object, and the operation will be dispatched using reflection on its type and a C# “runtime binder” which implements C#’s lookup and overload resolution semantics at runtime. This is essentially a part of the C# compiler running as a runtime component to “finish the work” on dynamic operations that was deferred by the static compiler. Example Assume the following code: dynamic d1 = new Foo(); dynamic d2 = new Bar(); string s; d1.M(s, d2, 3, null); Because the receiver of the call to M is dynamic, the C# compiler does not try to resolve the meaning of the call. Instead it stashes away information for the runtime about the call. This information (often referred to as the “payload”) is essentially equivalent to: “Perform an instance method call of M with the following arguments: 1. a string 2. a dynamic 3. a literal int 3 4. a literal object null” At runtime, assume that the actual type Foo of d1 is not a COM type and does not implement IDynamicObject. In this case the C# runtime binder picks up to finish the overload resolution job based on runtime type information, proceeding as follows: 1. Reflection is used to obtain the actual runtime types of the two objects, d1 and d2, that did not have a static type (or rather had the static type dynamic). The result is Foo for d1 and Bar for d2. 2. Method lookup and overload resolution is performed on the type Foo with the call M(string,Bar,3,null) using ordinary C# semantics. 3. If the method is found it is invoked; otherwise a runtime exception is thrown. Overload resolution with dynamic arguments Even if the receiver of a method call is of a static type, overload resolution can still happen at runtime. This can happen if one or more of the arguments have the type dynamic: Foo foo = new Foo(); dynamic d = new Bar(); var result = foo.M(d); The C# runtime binder will choose between the statically known overloads of M on Foo, based on the runtime type of d, namely Bar. The result is again of type dynamic. The Dynamic Language Runtime An important component in the underlying implementation of dynamic lookup is the Dynamic Language Runtime (DLR), which is a new API in .NET 4.0. The DLR provides most of the infrastructure behind not only C# dynamic lookup but also the implementation of several dynamic programming languages on .NET, such as IronPython and IronRuby. Through this common infrastructure a high degree of interoperability is ensured, but just as importantly the DLR provides excellent caching mechanisms which serve to greatly enhance the efficiency of runtime dispatch. To the user of dynamic lookup in C#, the DLR is invisible except for the improved efficiency. However, if you want to implement your own dynamically dispatched objects, the IDynamicObject interface allows you to interoperate with the DLR and plug in your own behavior. This is a rather advanced task, which requires you to understand a good deal more about the inner workings of the DLR. For API writers, however, it can definitely be worth the trouble in order to vastly improve the usability of e.g. a library representing an inherently dynamic domain. Open issues There are a few limitations and things that might work differently than you would expect. · The DLR allows objects to be created from objects that represent classes. However, the current implementation of C# doesn’t have syntax to support this. · Dynamic lookup will not be able to find extension methods. Whether extension methods apply or not depends on the static context of the call (i.e. which using clauses occur), and this context information is not currently kept as part of the payload. · Anonymous functions (i.e. lambda expressions) cannot appear as arguments to a dynamic method call. The compiler cannot bind (i.e. “understand”) an anonymous function without knowing what type it is converted to. One consequence of these limitations is that you cannot easily use LINQ queries over dynamic objects: dynamic collection = …; var result = collection.Select(e => e + 5); If the Select method is an extension method, dynamic lookup will not find it. Even if it is an instance method, the above does not compile, because a lambda expression cannot be passed as an argument to a dynamic operation. There are no plans to address these limitations in C# 4.0. Named and Optional Arguments Named and optional parameters are really two distinct features, but are often useful together. Optional parameters allow you to omit arguments to member invocations, whereas named arguments is a way to provide an argument using the name of the corresponding parameter instead of relying on its position in the parameter list. Some APIs, most notably COM interfaces such as the Office automation APIs, are written specifically with named and optional parameters in mind. Up until now it has been very painful to call into these APIs from C#, with sometimes as many as thirty arguments having to be explicitly passed, most of which have reasonable default values and could be omitted. Even in APIs for .NET however you sometimes find yourself compelled to write many overloads of a method with different combinations of parameters, in order to provide maximum usability to the callers. Optional parameters are a useful alternative for these situations. Optional parameters A parameter is declared optional simply by providing a default value for it: public void M(int x, int y = 5, int z = 7); Here y and z are optional parameters and can be omitted in calls: M(1, 2, 3); // ordinary call of M M(1, 2); // omitting z – equivalent to M(1, 2, 7) M(1); // omitting both y and z – equivalent to M(1, 5, 7) Named and optional arguments C# 4.0 does not permit you to omit arguments between commas as in M(1,,3). This could lead to highly unreadable comma-counting code. Instead any argument can be passed by name. Thus if you want to omit only y from a call of M you can write: M(1, z: 3); // passing z by name or M(x: 1, z: 3); // passing both x and z by name or even M(z: 3, x: 1); // reversing the order of arguments All forms are equivalent, except that arguments are always evaluated in the order they appear, so in the last example the 3 is evaluated before the 1. Optional and named arguments can be used not only with methods but also with indexers and constructors. Overload resolution Named and optional arguments affect overload resolution, but the changes are relatively simple: A signature is applicable if all its parameters are either optional or have exactly one corresponding argument (by name or position) in the call which is convertible to the parameter type. Betterness rules on conversions are only applied for arguments that are explicitly given – omitted optional arguments are ignored for betterness purposes. If two signatures are equally good, one that does not omit optional parameters is preferred. M(string s, int i = 1); M(object o); M(int i, string s = “Hello”); M(int i); M(5); Given these overloads, we can see the working of the rules above. M(string,int) is not applicable because 5 doesn’t convert to string. M(int,string) is applicable because its second parameter is optional, and so, obviously are M(object) and M(int). M(int,string) and M(int) are both better than M(object) because the conversion from 5 to int is better than the conversion from 5 to object. Finally M(int) is better than M(int,string) because no optional arguments are omitted. Thus the method that gets called is M(int). Features for COM interop Dynamic lookup as well as named and optional parameters greatly improve the experience of interoperating with COM APIs such as the Office Automation APIs. In order to remove even more of the speed bumps, a couple of small COM-specific features are also added to C# 4.0. Dynamic import Many COM methods accept and return variant types, which are represented in the PIAs as object. In the vast majority of cases, a programmer calling these methods already knows the static type of a returned object from context, but explicitly has to perform a cast on the returned value to make use of that knowledge. These casts are so common that they constitute a major nuisance. In order to facilitate a smoother experience, you can now choose to import these COM APIs in such a way that variants are instead represented using the type dynamic. In other words, from your point of view, COM signatures now have occurrences of dynamic instead of object in them. This means that you can easily access members directly off a returned object, or you can assign it to a strongly typed local variable without having to cast. To illustrate, you can now say excel.Cells[1, 1].Value = "Hello"; instead of ((Excel.Range)excel.Cells[1, 1]).Value2 = "Hello"; and Excel.Range range = excel.Cells[1, 1]; instead of Excel.Range range = (Excel.Range)excel.Cells[1, 1]; Compiling without PIAs Primary Interop Assemblies are large .NET assemblies generated from COM interfaces to facilitate strongly typed interoperability. They provide great support at design time, where your experience of the interop is as good as if the types where really defined in .NET. However, at runtime these large assemblies can easily bloat your program, and also cause versioning issues because they are distributed independently of your application. The no-PIA feature allows you to continue to use PIAs at design time without having them around at runtime. Instead, the C# compiler will bake the small part of the PIA that a program actually uses directly into its assembly. At runtime the PIA does not have to be loaded. Omitting ref Because of a different programming model, many COM APIs contain a lot of reference parameters. Contrary to refs in C#, these are typically not meant to mutate a passed-in argument for the subsequent benefit of the caller, but are simply another way of passing value parameters. It therefore seems unreasonable that a C# programmer should have to create temporary variables for all such ref parameters and pass these by reference. Instead, specifically for COM methods, the C# compiler will allow you to pass arguments by value to such a method, and will automatically generate temporary variables to hold the passed-in values, subsequently discarding these when the call returns. In this way the caller sees value semantics, and will not experience any side effects, but the called method still gets a reference. Open issues A few COM interface features still are not surfaced in C#. Most notably these include indexed properties and default properties. As mentioned above these will be respected if you access COM dynamically, but statically typed C# code will still not recognize them. There are currently no plans to address these remaining speed bumps in C# 4.0. Variance An aspect of generics that often comes across as surprising is that the following is illegal: IList<string> strings = new List<string>(); IList<object> objects = strings; The second assignment is disallowed because strings does not have the same element type as objects. There is a perfectly good reason for this. If it were allowed you could write: objects[0] = 5; string s = strings[0]; Allowing an int to be inserted into a list of strings and subsequently extracted as a string. This would be a breach of type safety. However, there are certain interfaces where the above cannot occur, notably where there is no way to insert an object into the collection. Such an interface is IEnumerable<T>. If instead you say: IEnumerable<object> objects = strings; There is no way we can put the wrong kind of thing into strings through objects, because objects doesn’t have a method that takes an element in. Variance is about allowing assignments such as this in cases where it is safe. The result is that a lot of situations that were previously surprising now just work. Covariance In .NET 4.0 the IEnumerable<T> interface will be declared in the following way: public interface IEnumerable<out T> : IEnumerable { IEnumerator<T> GetEnumerator(); } public interface IEnumerator<out T> : IEnumerator { bool MoveNext(); T Current { get; } } The “out” in these declarations signifies that the T can only occur in output position in the interface – the compiler will complain otherwise. In return for this restriction, the interface becomes “covariant” in T, which means that an IEnumerable<A> is considered an IEnumerable<B> if A has a reference conversion to B. As a result, any sequence of strings is also e.g. a sequence of objects. This is useful e.g. in many LINQ methods. Using the declarations above: var result = strings.Union(objects); // succeeds with an IEnumerable<object> This would previously have been disallowed, and you would have had to to some cumbersome wrapping to get the two sequences to have the same element type. Contravariance Type parameters can also have an “in” modifier, restricting them to occur only in input positions. An example is IComparer<T>: public interface IComparer<in T> { public int Compare(T left, T right); } The somewhat baffling result is that an IComparer<object> can in fact be considered an IComparer<string>! It makes sense when you think about it: If a comparer can compare any two objects, it can certainly also compare two strings. This property is referred to as contravariance. A generic type can have both in and out modifiers on its type parameters, as is the case with the Func<…> delegate types: public delegate TResult Func<in TArg, out TResult>(TArg arg); Obviously the argument only ever comes in, and the result only ever comes out. Therefore a Func<object,string> can in fact be used as a Func<string,object>. Limitations Variant type parameters can only be declared on interfaces and delegate types, due to a restriction in the CLR. Variance only applies when there is a reference conversion between the type arguments. For instance, an IEnumerable<int> is not an IEnumerable<object> because the conversion from int to object is a boxing conversion, not a reference conversion. Also please note that the CTP does not contain the new versions of the .NET types mentioned above. In order to experiment with variance you have to declare your own variant interfaces and delegate types. COM Example Here is a larger Office automation example that shows many of the new C# features in action. using System; using System.Diagnostics; using System.Linq; using Excel = Microsoft.Office.Interop.Excel; using Word = Microsoft.Office.Interop.Word; class Program { static void Main(string[] args) { var excel = new Excel.Application(); excel.Visible = true; excel.Workbooks.Add(); // optional arguments omitted excel.Cells[1, 1].Value = "Process Name"; // no casts; Value dynamically excel.Cells[1, 2].Value = "Memory Usage"; // accessed var processes = Process.GetProcesses() .OrderByDescending(p =&gt; p.WorkingSet) .Take(10); int i = 2; foreach (var p in processes) { excel.Cells[i, 1].Value = p.ProcessName; // no casts excel.Cells[i, 2].Value = p.WorkingSet; // no casts i++; } Excel.Range range = excel.Cells[1, 1]; // no casts Excel.Chart chart = excel.ActiveWorkbook.Charts. Add(After: excel.ActiveSheet); // named and optional arguments chart.ChartWizard( Source: range.CurrentRegion, Title: "Memory Usage in " + Environment.MachineName); //named+optional chart.ChartStyle = 45; chart.CopyPicture(Excel.XlPictureAppearance.xlScreen, Excel.XlCopyPictureFormat.xlBitmap, Excel.XlPictureAppearance.xlScreen); var word = new Word.Application(); word.Visible = true; word.Documents.Add(); // optional arguments word.Selection.Paste(); } } The code is much more terse and readable than the C# 3.0 counterpart. Note especially how the Value property is accessed dynamically. This is actually an indexed property, i.e. a property that takes an argument; something which C# does not understand. However the argument is optional. Since the access is dynamic, it goes through the runtime COM binder which knows to substitute the default value and call the indexed property. Thus, dynamic COM allows you to avoid accesses to the puzzling Value2 property of Excel ranges. Relationship with Visual Basic A number of the features introduced to C# 4.0 already exist or will be introduced in some form or other in Visual Basic: · Late binding in VB is similar in many ways to dynamic lookup in C#, and can be expected to make more use of the DLR in the future, leading to further parity with C#. · Named and optional arguments have been part of Visual Basic for a long time, and the C# version of the feature is explicitly engineered with maximal VB interoperability in mind. · NoPIA and variance are both being introduced to VB and C# at the same time. VB in turn is adding a number of features that have hitherto been a mainstay of C#. As a result future versions of C# and VB will have much better feature parity, for the benefit of everyone. Resources All available resources concerning C# 4.0 can be accessed through the C# Dev Center. Specifically, this white paper and other resources can be found at the Code Gallery site. Enjoy! span.fullpost {display:none;}

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Bypass BIOS password set by faulty Toshiba firmware on Satellite A55 laptop?

    - by Brian
    How can the CMOS be cleared on the Toshiba Satellite A55-S1065? I have this 7 year old laptop that has been crippled by a glitch in its BIOS: 'A "Password =" prompt may be displayed when the computer is turned on, even though no power-on password has been set. If this happens, there is no password that will satisfy the password request. The computer will be unusable until this problem is resolved. [..] The occurrence of this problem on any particular computer is unpredictable -- it may never happen, but it could happen any time that the computer is turned on. [..] Toshiba will cover the cost of this repair under warranty until Dec 31, 2010.' -Toshiba As they stated, this machine is "unusable." The escape key does not bypass the prompt (nor does any other key), thus no operating system can be booted and no firmware updates can be installed. After doing some research, I found solutions that have been suggested for various Toshiba Satellite models afflicted by this glitch: "Make arrangements with a Toshiba Authorized Service Provider to have this problem resolved." -Toshiba (same link). Even prior to the expiration of Toshiba's support ("repair under warranty until Dec 31, 2010"), there have been reports that this solution is prohibitively expensive, labor charges accruing even when the laptop is still under warranty, and other reports that are generally discouraging: "They were unable to fix it and the guy who worked on it said he couldn’t find the jumpers on the motherboard to clear the BIOS. I paid $39 for my troubles and still have the password problem." - Steve. Since the costs of the repairs can now exceed the value of the hardware, it would seem this is a DIY solution, or a non-solution (i.e. the hardware is trash). Build a Toshiba parallel loopback by stripping and soldering the wires on a DB25 plug to connect connect these pins: 1-5-10, 2-11, 3-17, 4-12, 6-16, 7-13, 8-14, 9-15, 18-25. -CGSecurity. According to a list of supported models on pwcrack, this will likely not work for my Satellite A55-1065 (as well as many other models of similar age). -pwcrack Disconnect the laptop battery for an extended period of time. Doesn't work, laptop sat in a closet for several years without the battery connected and I forgot about the whole thing for awhile. The poor thing. Clear CMOS by setting the proper jumper setting or by removing the CMOS (RTC) battery, or by short circuiting a (hidden?) jumper that looks like a pair of solder marks -various sources for various Satellite models: Satellite A105: "you will see C88 clearly labeled right next the jack that the wireless card plugs into. There are two little solder squares (approx 1/16") at this location" -kerneltrap Satellite 1800: "Underneath the RAM there is black sticker, peel off the black sticker and you will reveal two little solder marks which are actually 'jumpers'. Very carefully hold a flat-head screwdriver touching both points and power on the unit briefly, effectively 'shorting' this circuit." -shadowfax2020 Satellite L300: "Short the B500 solder pads on the system board." -Lester Escobar Satellite A215: "Short the B500 solder pads on the system board." -fixya Clearing the CMOS could resolve the issue, but I cannot locate a jumper or a battery on this board. Nothing that looks remotely like a battery can be removed (everything is soldered). I have looked closely at the area around the memory and do not see any obvious solder pads that could be a secret jumper. Here are pictures (click for full resolution) : Where is the jumper (or solder pads) to short circuit and wipe the CMOS on this board? Possibly related questions: Remove Toshiba laptop BIOS password? Password Problem Toshiba Satellite..

    Read the article

  • CPU Temperature sensor wrong?

    - by Matias Nino
    Everest Ultimate is suddenly telling me that the CPU temperature (and core temps) for my E6850 Core 2 Duo is 72 degrees Celsius. When I stress-test the machine, the temp goes up to 91 degrees and the CPU actually throttles. System remains stable though. For over a year now, my CPU has run very cool (40's) with a large commercial copper heatsink/fan that I bought separately. To top it off, I removed the cover of the box and felt the cpu heatsink and it wasn't even warm. Is there such a thing as a CPU temp sensor showing the wrong readings? Any tips would help. UPDATE #1 Temp is also just as high in BIOS. So that leads me to believe it's a CPU seating issue (even though I used thermal paste to seat it two years ago when I built the machine) UPDATE #2 Well. I removed the heatsink and cleaned off the original thermal paste (which was somewhat crusty). I polished the surface, re-applied some new paste, and reseated the heat sink. After powering it up, there was no noticeable change in the temp - ideling at 74. Ran the stress test and it went up to 94 degrees before being 100% throttled. I let it sit at 94 degrees for 20 minutes straight and the computer didn't even flinch. I then immediately shut it off and opened the case and felt around. The heatsink was completely cold to the touch. Even the copper rods were cold. The area near contact with the CPU was slightly warm but not hot to touch. Then I ran REALTEMP, which is supposedly more accurate and it told me the CPU was at 104 degrees. (LOL) At this point, I'm thinking no doubt the cpu's sensor is wrong. Sidenote: the BIOS has the latest version so no option to flash there. Reverting hasn't been known to help from what I've read. What pisses me off is the false temps force the CPU to artificially throttle from 3GHz down to 2GHz and my CPU fan is cranking at full force all the time. Should I call intel and tell them to send me another E6850? SOLUTION UPDATE I switched the processor out with another one and got the same obscene temperatures with the new processor followed by a heatsink that was cool to touch. My suspicion in the heatsink was suddenly renewed. I swapped it out with the stock heatsink/fan and lo and behold the temperatures returned to the normal 35C-50C. Even though the thermal paste was visibly flattened out every time I removed it, it looks like the heatsink was still not pressing hard enough on the CPU to effectively conduct the heat. The heatsink is a Masscool 8Wa741, which screws into a standard position on a mount on the back of the MOBO. Only thing I can surmise after 2 years of use was that, over time, the heatsink pressure on the CPU gave way until the heat began to be ineffectively conducted. Lessons learned: Intel CPU's can run SUPER HOT (upwards of 95C) and still be stable. Heatsink's need to be VERY firmly pressed against the CPU to conduct heat.

    Read the article

  • Disk operations freeze Debian

    - by Grzenio
    Hi, I have just installed Debian testing on my new desktop and I am not very happy with performance - when I perform a disk intensive operation, e.g. upgrade packages in the system, everything seems to freeze, e.g. changing tabs in Iceweasel takes 3 seconds. I run the Debian on my 3 year old Thinkpad X60 ultra-portable, and I don't have these issues. (every single parameter of the laptop is much worse than the desktop). I am using the default packaged kernel and scripts. I run hdparm -t /dev/sda1 And I got around 96GB/s, which is expected. What else can I try to make it work better? EDIT: grzes:/home/ga# hdparm -i /dev/sda /dev/sda: Model=WDC WD15EARS-00Z5B1, FwRev=80.00A80, SerialNo=WD-WMAVU1362357 Config={ HardSect NotMFM HdSw>15uSec SpinMotCtl Fixed DTR>5Mbs FmtGapReq } RawCHS=16383/16/63, TrkSize=0, SectSize=0, ECCbytes=50 BuffType=unknown, BuffSize=unknown, MaxMultSect=16, MultSect=16 CurCHS=16383/16/63, CurSects=16514064, LBA=yes, LBAsects=2930277168 IORDY=on/off, tPIO={min:120,w/IORDY:120}, tDMA={min:120,rec:120} PIO modes: pio0 pio3 pio4 DMA modes: mdma0 mdma1 mdma2 UDMA modes: udma0 udma1 udma2 udma3 udma4 udma5 *udma6 AdvancedPM=no WriteCache=enabled Drive conforms to: Unspecified: ATA/ATAPI-1,2,3,4,5,6,7 * signifies the current active mode EDIT2: Even my wife said "on this new computer I can't do anything when I copy the photos from the camera and its much worse than on the old one". So it must be serious. EDIT3: Updated to 2.6.32, but still no improvement EDIT4: I forgot to mention that the new disk is ext4, the old was ext3. EDIT5: Still not solved. I have a P43 ASUS P5QL-E board. Lines from dmesg that seem relevant: [ 0.370850] Block layer SCSI generic (bsg) driver version 0.4 loaded (major 253) [ 0.370852] io scheduler noop registered [ 0.370853] io scheduler anticipatory registered [ 0.370854] io scheduler deadline registered [ 0.370876] io scheduler cfq registered (default) ... [ 0.908233] ata_piix 0000:00:1f.2: version 2.13 [ 0.908243] ata_piix 0000:00:1f.2: PCI INT B -> GSI 19 (level, low) -> IRQ 19 [ 0.908246] ata_piix 0000:00:1f.2: MAP [ P0 P2 P1 P3 ] [ 0.908275] ata_piix 0000:00:1f.2: setting latency timer to 64 [ 0.908316] scsi0 : ata_piix [ 0.908374] scsi1 : ata_piix [ 0.909180] ata1: SATA max UDMA/133 cmd 0xa000 ctl 0x9c00 bmdma 0x9480 irq 19 [ 0.909183] ata2: SATA max UDMA/133 cmd 0x9880 ctl 0x9800 bmdma 0x9488 irq 19 [ 0.909199] ata_piix 0000:00:1f.5: PCI INT B -> GSI 19 (level, low) -> IRQ 19 [ 0.909202] ata_piix 0000:00:1f.5: MAP [ P0 -- P1 -- ] [ 0.909228] ata_piix 0000:00:1f.5: setting latency timer to 64 [ 0.909279] scsi2 : ata_piix [ 0.909326] scsi3 : ata_piix [ 0.910021] ata3: SATA max UDMA/133 cmd 0xb000 ctl 0xac00 bmdma 0xa480 irq 19 [ 0.910024] ata4: SATA max UDMA/133 cmd 0xa880 ctl 0xa800 bmdma 0xa488 irq 19 [ 0.915575] FDC 0 is a post-1991 82077 ... [ 1.716062] ata1.00: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [ 1.716074] ata1.01: SATA link down (SStatus 0 SControl 300) [ 1.724318] ata1.00: ATA-8: WDC WD15EARS-00Z5B1, 80.00A80, max UDMA/133 [ 1.724322] ata1.00: 2930277168 sectors, multi 16: LBA48 NCQ (depth 0/32) [ 1.740339] ata1.00: configured for UDMA/133 [ 1.740428] scsi 0:0:0:0: Direct-Access ATA WDC WD15EARS-00Z 80.0 PQ: 0 ANSI: 5 [ 1.746788] scsi 6:0:0:0: CD-ROM ASUS DRW-1608P 1.17 PQ: 0 ANSI: 5 ... [ 1.925981] sd 0:0:0:0: [sda] 2930277168 512-byte logical blocks: (1.50 TB/1.36 TiB) [ 1.926005] sd 0:0:0:0: [sda] Write Protect is off [ 1.926007] sd 0:0:0:0: [sda] Mode Sense: 00 3a 00 00 [ 1.926020] sd 0:0:0:0: [sda] Write cache: enabled, read cache: enabled, doesn't support DPO or FUA [ 1.926092] sda:sr0: scsi3-mmc drive: 40x/40x writer cd/rw xa/form2 cdda tray [ 1.931106] Uniform CD-ROM driver Revision: 3.20 [ 1.931191] sr 6:0:0:0: Attached scsi CD-ROM sr0 ... [ 1.941936] sda1 sda2 sda3 sda4 < sda5 sda6 > [ 1.967691] sd 0:0:0:0: [sda] Attached SCSI disk [ 1.970938] sd 0:0:0:0: Attached scsi generic sg0 type 0 [ 1.970959] sr 6:0:0:0: Attached scsi generic sg1 type 5 ... [ 2.500086] EXT4-fs (sda3): mounted filesystem with ordered data mode ... [ 7.150468] EXT4-fs (sda6): mounted filesystem with ordered data mode

    Read the article

  • xrandr shows two displays (LVDS1), but how can I use VGA1 only?

    - by Tom Fishman
    We're running Ubuntu 11 on this hardware: Foxconn R20-D2 Intel Atom D510 Intel NM10 Intel GMA 3150 Barebone There is no integrated display (it is a barebone box). I connected an external VGA to it. However xrandr shows two displays: Screen 0: minimum 320 x 200, current 1024 x 768, maximum 4096 x 4096 LVDS1 connected 1024x768+0+0 (normal left inverted right x axis y axis) 0mm x 0mm 1024x768 60.0*+ 800x600 60.3 56.2 640x480 59.9 VGA1 connected 1024x768+0+0 (normal left inverted right x axis y axis) 519mm x 324mm 1920x1200 60.0 + 1600x1200 60.0 1680x1050 60.0 1280x1024 76.0 75.0 72.0 60.0 1440x900 75.0 59.9 1152x864 75.0 1024x768 75.1 70.1 60.0* 832x624 74.6 800x600 72.2 75.0 60.3 640x480 72.8 75.0 66.7 60.0 720x400 70.1 But I don't have two displays. How can I get rid of LVDS1 and use only VGA1? The direct result is that I'm seeing a 1024x768 resolution on my VGA display, because the OS is using "mirror" mode which uses the lower resolution of the two. Turning off the mirror is not a solution. I want to fix it. Related logs: ... [ 20.019] (II) intel(0): Creating default Display subsection in Screen section "Default Screen Section" for depth/fbbpp 24/32 [ 20.019] (==) intel(0): Depth 24, (--) framebuffer bpp 32 [ 20.019] (==) intel(0): RGB weight 888 [ 20.019] (==) intel(0): Default visual is TrueColor [ 20.019] (II) intel(0): Integrated Graphics Chipset: Intel(R) Pineview G [ 20.019] (--) intel(0): Chipset: "Pineview G" [ 20.019] (**) intel(0): Relaxed fencing enabled [ 20.019] (**) intel(0): Wait on SwapBuffers? enabled [ 20.019] (**) intel(0): Triple buffering? enabled [ 20.019] (**) intel(0): Framebuffer tiled [ 20.019] (**) intel(0): Pixmaps tiled [ 20.020] (**) intel(0): 3D buffers tiled [ 20.020] (**) intel(0): SwapBuffers wait enabled [ 20.020] (==) intel(0): video overlay key set to 0x101fe [ 20.020] (II) intel(0): Output LVDS1 has no monitor section [ 20.020] (II) intel(0): found backlight control interface /sys/class/backlight/intel_backlight [ 20.080] (II) intel(0): Output VGA1 has no monitor section [ 20.080] (II) intel(0): EDID for output LVDS1 [ 20.081] (II) intel(0): Not using default mode "320x240" (doublescan mode not supported) [ 20.081] (II) intel(0): Not using default mode "400x300" (doublescan mode not supported) [ 20.081] (II) intel(0): Not using default mode "400x300" (doublescan mode not supported) [ 20.081] (II) intel(0): Not using default mode "512x384" (doublescan mode not supported) ... [ 20.082] (II) intel(0): Not using default mode "960x600" (doublescan mode not supported) [ 20.082] (II) intel(0): Printing probed modes for output LVDS1 [ 20.082] (II) intel(0): Modeline "1024x768"x60.0 65.00 1024 1048 1184 1344 768 771 777 806 -hsync -vsync (48.4 kHz) [ 20.082] (II) intel(0): Modeline "800x600"x60.3 40.00 800 840 968 1056 600 601 605 628 +hsync +vsync (37.9 kHz) [ 20.082] (II) intel(0): Modeline "800x600"x56.2 36.00 800 824 896 1024 600 601 603 625 +hsync +vsync (35.2 kHz) [ 20.082] (II) intel(0): Modeline "640x480"x59.9 25.18 640 656 752 800 480 490 492 525 -hsync -vsync (31.5 kHz) [ 20.149] (II) intel(0): EDID for output VGA1 [ 20.149] (II) intel(0): Manufacturer: BNQ Model: 771b Serial#: 6595 [ 20.149] (II) intel(0): Year: 2008 Week: 16 [ 20.149] (II) intel(0): EDID Version: 1.3 [ 20.149] (II) intel(0): Analog Display Input, Input Voltage Level: 0.700/0.700 V ... [ 20.152] (II) intel(0): Modeline "640x480"x60.0 25.20 640 656 752 800 480 490 492 525 -hsync -vsync (31.5 kHz) [ 20.152] (II) intel(0): Modeline "720x400"x70.1 28.32 720 738 846 900 400 412 414 449 -hsync +vsync (31.5 kHz) [ 20.152] (II) intel(0): Output LVDS1 connected [ 20.152] (II) intel(0): Output VGA1 connected [ 20.152] (II) intel(0): Using exact sizes for initial modes [ 20.152] (II) intel(0): Output LVDS1 using initial mode 1024x768 [ 20.152] (II) intel(0): Output VGA1 using initial mode 1024x768 [ 20.152] (II) intel(0): Using default gamma of (1.0, 1.0, 1.0) unless otherwise stated. ...

    Read the article

  • Have I pushed the limits of my current VPS or is there room for optimization?

    - by JRameau
    I am currently on a mediatemple DV server (basic) 512mb dedicated ram, this is a CentOS based VPS with Plesk and Virtuozzo. My experience with it from day 1 has been bad and I only could sooth my server issues with several caching "Band-aids," but my sites are not as small as they were a year ago either so the issues have worsen. I have 3 Drupal installs running on separate (plesk) domains, 1 of those drupal installs is a multisite, that consists of 5-6 sites 2 of those sites are bringing in actual traffic. Those caching "Band-aids" I mentioned are APC, which seemed to help alot initially, and Drupal's Boost, which is considered a poorman's Varnish, it makes all my pages static for anonymous users. Last 30day combined estimate on Google Ananlytics: 90k visitors 260k pageviews. Issue: alot of downtime, I am continually checking if my sites are up, and lately I have been finding it down more than 3 times daily. Restarting Apache will bring it back up, for some time. I have google search every error message and looked up ways to optimize my DV server, and I am beyond stump what is my next move. Is this server bad, have I hit a impossibly low restriction such as the 12mb kernel memory barrier (kmemsize), is it on my end, do I need to optimize some more? *I have provided as much information as I can below, any help or suggestions given will be appreciated Common Error messages I see in the log: [error] (12)Cannot allocate memory: fork: Unable to fork new process [error] make_obcallback: could not import mod_python.apache.\n Traceback (most recent call last): File "/usr/lib/python2.4/site-packages/mod_python/apache.py", line 21, in ? import traceback File "/usr/lib/python2.4/traceback.py", line 3, in ? import linecache ImportError: No module named linecache [error] python_handler: no interpreter callback found. [warn-phpd] mmap cache can't open /var/www/vhosts/***/httpdocs/*** - Too many open files in system (pid ***) [alert] Child 8125 returned a Fatal error... Apache is exiting! [emerg] (43)Identifier removed: couldn't grab the accept mutex [emerg] (22)Invalid argument: couldn't release the accept mutex cat /proc/user_beancounters: Version: 2.5 uid resource held maxheld barrier limit failcnt 41548: kmemsize 4582652 5306699 12288832 13517715 21105036 lockedpages 0 0 600 600 0 privvmpages 38151 42676 229036 249036 0 shmpages 16274 16274 17237 17237 2 dummy 0 0 0 0 0 numproc 43 46 300 300 0 physpages 27260 29528 0 2147483647 0 vmguarpages 0 0 131072 2147483647 0 oomguarpages 27270 29538 131072 2147483647 0 numtcpsock 21 29 300 300 0 numflock 8 8 480 528 0 numpty 1 1 30 30 0 numsiginfo 0 1 1024 1024 0 tcpsndbuf 648440 675272 2867477 4096277 1711499 tcprcvbuf 301620 359716 2867477 4096277 0 othersockbuf 4472 4472 1433738 2662538 0 dgramrcvbuf 0 0 1433738 1433738 0 numothersock 12 12 300 300 0 dcachesize 0 0 2684271 2764800 0 numfile 3447 3496 6300 6300 3872 dummy 0 0 0 0 0 dummy 0 0 0 0 0 dummy 0 0 0 0 0 numiptent 14 14 200 200 0 TOP: (In January the load avg was really high 3-10, I was able to bring it down where it is currently is by giving APC more memory play around with) top - 16:46:07 up 2:13, 1 user, load average: 0.34, 0.20, 0.20 Tasks: 40 total, 2 running, 37 sleeping, 0 stopped, 1 zombie Cpu(s): 0.3% us, 0.1% sy, 0.0% ni, 99.7% id, 0.0% wa, 0.0% hi, 0.0% si Mem: 916144k total, 156668k used, 759476k free, 0k buffers Swap: 0k total, 0k used, 0k free, 0k cached MySQLTuner: (after optimizing every table and repairing any table with overage I got the fragmented count down to 86) [--] Data in MyISAM tables: 285M (Tables: 1105) [!!] Total fragmented tables: 86 [--] Up for: 2h 44m 38s (409K q [41.421 qps], 6K conn, TX: 1B, RX: 174M) [--] Reads / Writes: 79% / 21% [--] Total buffers: 58.0M global + 2.7M per thread (100 max threads) [!!] Query cache prunes per day: 675307 [!!] Temporary tables created on disk: 35% (7K on disk / 20K total)

    Read the article

  • Do I need to be worried about these SMART drive temperatures?

    - by Steve Lorimer
    I have 5 hard drives in a machine sitting in a cupboard. /dev/sda is a 500GB Seagate drive, and is the boot disk. /dev/sd{b,c,d,e} are 2TB drives in a raid6 configuration. smartctl is showing significantly higher temperatures (like ~140 degrees celsius) on the raid drives than the boot drive. Do I need to be worried? /dev/sdb and /dev/sde are new Western Digital Black drives (new=1 week) /dev/sdc and /dev/sdd are 5 year old Hitachi drives /dev/sda [SAT], Temperature_Celsius changed from 40 to 39 /dev/sdc [SAT], Temperature_Celsius changed from 142 to 146 /dev/sdc [SAT], Temperature_Celsius changed from 146 to 142 /dev/sdd [SAT], Temperature_Celsius changed from 142 to 146 /dev/sda [SAT], Airflow_Temperature_Cel changed from 61 to 62 /dev/sda [SAT], Temperature_Celsius changed from 39 to 38 /dev/sde [SAT], Temperature_Celsius changed from 107 to 108 /dev/sdb [SAT], Temperature_Celsius changed from 108 to 109 /dev/sdc [SAT], Temperature_Celsius changed from 146 to 150 /dev/sdc [SAT], Temperature_Celsius changed from 146 to 150 /dev/sda [SAT], Airflow_Temperature_Cel changed from 62 to 61 /dev/sda [SAT], Temperature_Celsius changed from 38 to 39 Update: Adding detailed drive information as per request: /dev/sda =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Pipeline HD 5900.2 Device Model: ST3500312CS Serial Number: 5VV47HXA LU WWN Device Id: 5 000c50 02aad5ad6 Firmware Version: SC13 User Capacity: 500,107,862,016 bytes [500 GB] Sector Size: 512 bytes logical/physical Rotation Rate: 5900 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 1.5 Gb/s (current: 1.5 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled /dev/sdb =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WDC WD2003FZEX-00Z4SA0 Serial Number: WD-WMC1F1398726 LU WWN Device Id: 5 0014ee 003b8bd25 Firmware Version: 01.01A01 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled /dev/sdc =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Deskstar 7K3000 Device Model: Hitachi HDS723020BLA642 Serial Number: MN1220F30WSTUD LU WWN Device Id: 5 000cca 369cc9f5d Firmware Version: MN6OA580 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled /dev/sdd =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Deskstar 7K3000 Device Model: Hitachi HDS723020BLA642 Serial Number: MN1220F30WST4D LU WWN Device Id: 5 000cca 369cc9f48 Firmware Version: MN6OA580 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 1.5 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled /dev/sde =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WDC WD2003FZEX-00Z4SA0 Serial Number: WD-WMC1F1483782 LU WWN Device Id: 5 0014ee 3002d235c Firmware Version: 01.01A01 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 1.5 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled

    Read the article

  • BSOD & System Failure after trying to install a new RAM

    - by Praveen Kumar
    I have updated the question with sections, so that people won't find it difficult to read. Basic System Information Let me give a basic introduction on my system. I have a system of following configuration: Processor: Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz 3.40GHz RAM: Corsair Vengeance - 4GB Single Module DDR3 Memory Kit (CMZ4GX3M1A1600C9) x 2 OS: Windows 7 Ultimate, SP1 Build 7601 HDD: 1 TB Seagate 7200 RPM The Problem It was working fine for about an year. Yesterday I planned to increase my RAM to 16 GB by putting another set of two Corsair Vengeance - 4GB Single Module DDR3 Memory Kit (CMZ4GX3M1A1600C9). I got it from an authorized reseller and also, the RAM was fitted by a service engineer only. After the RAM was fit (all the four), the system failed to start, with an error code of 0x000000f4. The complete information of it is: Problem signature: Problem Event Name: BlueScreen OS Version: 6.1.7601.2.1.0.256.1 Locale ID: 16393 Additional information about the problem: BCCode: f4 BCP1: 0000000000000003 BCP2: FFFFFA8008A39060 BCP3: FFFFFA8008A39340 BCP4: FFFFF800037C8510 OS Version: 6_1_7601 Service Pack: 1_0 Product: 256_1 Files that help describe the problem: C:\Windows\Minidump\093012-13041-01.dmp C:\Users\Praveen Kumar\AppData\Local\Temp\WER-30716-0.sysdata.xml Read our privacy statement online: http://go.microsoft.com/fwlink/?linkid=104288&clcid=0x0409 If the online privacy statement is not available, please read our privacy statement offline: C:\Windows\system32\en-US\erofflps.txt Another Problem We first thought that it was the RAM, which caused the issue. So I returned the RAMs and now my computer configuration is exactly how it was the previous day. But, following the removal of the RAM, I also had several crashes after that. One suspicious thing was with an error code c0000134: STOP: c0000135 The program can’t start because %hs is missing from your computer . Try resintalling the program to fix this problem. After reading contents from this, this and this, which were never my case, they didn't help me. But I didn't receive any more STOP c0000134 messages. But this 0x000000f4 keeps on coming. I am writing from the same system and it allows me to work for say, half an hour max. Then I hear a device disconnect sound, the one you hear in Windows 7, when a USB Mass Storage Device is plugged out. Immediately following that, my screen goes blank and I get 0x000000f4 blue screen. Okay, now I am really concerned about my Hard Disk data, but I have no clue if there is a problem with the HDD. My Question What all files do I need to submit for your reference? Can this issue be fixed? I am getting more time if I remove my RAM, clean it and then put it back. Weird! Hope I have given the necessary information to help you guys. Thanks in advance. Minidumps I have uploaded all the Minidump DMP files from C:\Windows\Minidump folder here: http://www.praveen-kumar.com/Minidumps.zip Let me know if you face any issues in accessing it. Will be able to share elsewhere. Updates 30-Sep-2012 10:15 AM IST: When I keep the system cover opened, pressed the HDD Cable well, it is allowing me to be on for about half an hour, I guess? Also, I feel that the CPU fan speed is kind of slow. It rotates at around 900 RPM, but the CPU Temperature is not more than 70° C. 30-Sep-2012 10:30 AM IST: My Modem (Beetel 220BX ADSL2+ Router) failed. I have no idea how it is related to this issue, but I thought that I need to document this too. I really have a bad day here. 30-Sep-2012 11:00 AM IST: System still running fine, with the cabinet cover open, now for about an hour. 30-Sep-2012 12:00 PM IST: I shut down the system and closed the cabinet. Started the system, and it hung after giving the password. After a few minutes, got the same 0x000000f4 error. So, while it is in the upright position, fixed the Hard Disk cable and now it is booting fine. Waiting for more observations and answers.

    Read the article

  • How to diagnose computer lockup/freezing problem

    - by Scott Mitchell
    I built a desktop computer a couple years back with the following specs: CPU: Intel Core 2 Quad Q9300 Yorkfield 2.5GHz 6MB L2 Cache LGA 775 95W Quad-Core Processor BX80580Q9300 Motherboard: EVGA 122-CK-NF68-T1 LGA 775 NVIDIA nForce 680i SLI ATX Intel Motherboard Video Card: Two EVGA 256-P2-N758-TR GeForce 8600GT SCC 256MB 128-bit GDDR3 PCI Express x16 SLI Supported Video Card PSU: SeaSonic S12 Energy Plus SS-550HT 550W ATX12V V2.3 / EPS12V V2.91 SLI Certified CrossFire Ready 80 PLUS Certified Active PFC Power Supply Memory: Two G.SKILL 4GB (2 x 2GB) 240-Pin DDR2 SDRAM DDR2 800 (PC2 6400) Dual Channel Kit Desktop Memory Model F2-6400CL5D-4GBPQ Since its inception, the machine has periodically locked up, the regularlity having varied over the years from once a day to once a month. Typically, lockups happen once every few days. By "lockup" I mean my computer just freezes. The screen locks up, I can't move the mouse. Hitting keys on my keyboard that normally turn LEDs on or off on the keyboard (such as Caps Lock) no longer turn the LEDs on or off. If there was music playing at the time of the lockup, noise keeps coming out of the speakers, but it's just the current frequency/note that plays indefinitely. There is no BSOD. When such a lockup occurs I have to do a hard reboot by either turning off the computer or hitting the reset button. I have the most recent version of the NVIDIA hardware drivers, and update them semi-regularly, but that hasn't seemed to help. I am currently using Windows 7 x64, but was previously using Windows Server 2003 x64 and having the same lockup issues. My guess is that it's somehow video driver or motherboard related, but I don't know how to go about diagnosing this problem to narrow down which of the two is the culprit. Additional information re: cooling Regarding cooling... I've not installed any after-market cooling systems aside from two regular fans I scavenged from an older computer. The fan atop the CPU is the one that shipped with it. One of the two scavenged fans I added it located at the bottom tower of the corner, in an attempt to create some airflow from front to back. The second fan is pointed directly at the two video cards. SpeedFan installation and readings Per studiohack's suggestion, I installed SpeedFan, which provided the following temperature readings: GPU: 63C GPU: 65C System: 76C CPU: 64C AUX: 36C Core 0: 78C Core 1: 76C Core 2: 79C Core 3: 79C Update #3: Another Lockup :-( Well, I had another lockup last night. :-( SpeedFan reported the CPU temp at 38 C when it happened, and there was no spike in temperature leading up to the freeze. One thing I notice is that the freeze seems more likely to happen if I am watching a video. In fact, of the last 5 freezes over the past month, 4 of them have been while watching a video on Flickr. Not necessarily the same video, but a video nevertheless. I don't know if this is just coincidence or if it means anything. (As an aside, each night before bedtime my 2 year old daughter sits on my lap and watches some home videos on Flickr and, in the last month, has learned the phrase, "Uh oh, computer broke.") Update #4: MemTest86 and 3DMark06 Test Results: Per suggestions in the comments, I ran the MemTest86 overnight and it cycled through the 8 GB of memory 5 times without error. I also ran the 3DMark06 test without a problem (see my scores at http://3dmark.com/3dm06/15163549). So... what now? :-) Any further suggestions on what to check? Is there some way to get a stack trace or something when the computer locks like that? Thanks

    Read the article

  • How clean is deleting a computer object?

    - by Kevin
    Though quite skilled at software development, I'm a novice when it comes to Active Directory. I've noticed that AD seems to have a lot of stuff buried in the directory and schema which does not appear superficially when using simplified tools such as Active Directory Users and Computers. It kind of feels like the Windows registry, where COM classes have all kinds of intertwined references, many of which are purely by GUID, such that it's not enough to just search for anything referencing "GadgetXyz" by name in order to cleanly remove GadgetXyz. This occasionally leads to the uneasy feeling that I may have useless garbage building up in there which I have no idea how to weed out. For instance, I made the mistake a while back of trying to rename a DC, figuring I could just do it in the usual manner from Control Panel. I found references to the old name buried all over the place which made it impossible to reuse that name without considerable manual cleanup. Even long after I got it all working, I've stumbled upon the old name hidden away in LDAP. (There were no other DCs left in the picture at that time so I don't think it was a tombstone issue.) More specifically, I'm worried about the case of just outright deleting a computer from AD. I understand the cleanest way to do it is to log into the computer itself and tell it to leave the domain. (As an aside, doing this in Windows 8 seems to only disable the computer object and not delete it outright!) My concern is cases where this is not possible, for instance because it was on an already-deleted VM image. I can simply go into Active Directory Users and Computers, find the computer object, click it, and press Delete, and it seems to go away. My question is, is it totally, totally gone, or could this leave hanging references in any Active Directory nook or cranny I won't know to look in? (Excluding of course the expected tombstone records which expire after a set time.) If so, is there any good way to clean up the mess? Thank you for any insight! Kevin ps., It was over a year ago so I don't remember the exact details, but here's the gist of the DC renaming issue. I started with a single 2008 DC named ABC in a physical machine and wanted to end up instead with a DC of the same name running in a vSphere VM. Not wanting to mess with imaging the physical machine, my plan instead was: Rename ABC to XYZ. Fresh install 2008 on a VM, name it ABC, and join it to the domain. (I may have done the latter in the same step as promoting to DC; I don't recall.) dcpromo the new ABC as a 2nd DC, including GC. Make sure the new ABC replicated correctly from XYZ and then transfer the FSMO roles from XYZ to it. Once everything was confirmed to work with the new ABC alone, demote XYZ, remove the AD role, and remove it from the domain. Eventually I managed to do this but it was a much bumpier ride than expected. In particular, I got errors trying to join the new ABC to the domain. These included "The pre-windows 2000 name is already in use" and "No mapping between account names and security IDs was done." I eventually found that the computer object for XYZ had attributes that still referred to it as ABC. Among these were servicePrincipalName, msDS-AdditionalDnsHostName, and msDS-AdditionalSamAccountName. The latter I could not edit via Attribute Editor and instead had to run this against XYZ: NETDOM computername <simple-name> /add:<FQDN> There were some other hitches I don't remember exactly.

    Read the article

  • Windows Server 2012 Migration (DNS/AD DS Standard Eval to Essentials OEM) P2V -> Do I need a Secondary Domain Controller during migration?

    - by Aubrey Robertson
    This is my first post on this exchange (although not my first on stack exchange), so please have patience. I am a 3rd year student intern, and I have been tasked with virtualizing the server systems at the company I work for. I have come a long way, and I am almost ready to install the VM Server in migration mode. Here is some information: Source Server: Windows Server 2012 Standard Evaluation DNS Server (local only) Advanced Directory Domain Services File and Storage stuff A few other server roles Destination Server: Windows Server 2012 Essentials OEM (Hyper-V client) Running under a temporary Hyper-V host (will migrate the Hyper-V host back to the old machine after the original server is virtualized as a client). Sitting currently at the "Select Installation Mode" screen. I have been following the guides on Microsoft tech net, and today I spent most of the day getting rid of issues in the Best Practices Analyser on the source machine. I have 3 remaining issues (which are all related): ERROR: DNS: DNS servers on Ethernet (adapter name) should include the loopback address, but not as the first entry (flavour text indicates that, during migration, the DNS server may not be found) WARNING: All domains should have at least two domain controllers for redundancy. WARNING: DNS: Ethernet should be configured to use both a preferred and an alternate DNS Server. All of these issues can be resolved by deploying a secondary domain controller, but I have never done that before (see my concerns below). The main issue here that I am concerned with for installing in migration mode is the FIRST one (the error). If I try and set-up the new server deployment, and the adapter domain controller is listed as localhost, then this may cause the installation to fail. (at least, this is what the Microsoft documentation suggests). But I do not have another IP address to enter here as I have no other local domain controllers. So I did the first obvious thing that came to my mind, and tried to use Google DNS servers as my alternates. That did not work because they couldn't recognize other computers in the "forest". Now I'm no expert when it comes to DNS, so please forgive my ignorance. This DNS server is concerned only with Active Directory stuffs for the local network. If I go ahead with migration, and it fails, then I will just have to go ahead and install a secondary DNS server I suppose. The problem I have here is that I am limited by the amount of Windows Server keys I have available (I have 2); however, I do have access to a Linux box running Debian Wheezy that I set-up two weeks ago as a Mantis server. I could install Windows Server 2012 as a secondary DNS (I think) in a VM and use that, but then it seems like I will be wasting time, and probably the Windows key too, and if there's another way to do it with Linux that would be much better. Even better still, do I even need a secondary DNS server for migration at all? The hints said that during migration the original machine "might" not be found. Thank you for your time and consideration.

    Read the article

  • Moving users folder on Windows-7 to another partition - bad idea?

    - by Donat
    Hi, I'd like to re-submit here a question posted by Benjol on Aug 17at 5:57 "Moving users folder on Windows Vista to another partition - bad idea?" (I can't post one than one link until I earn "10 reputation" and removed my "answer" there to post my follow-up questions here). I am anxiously getting ready at long last to to carry out a clean install (using custom install option) from Vista to Windows-7 Home Premium 64bit with the free upgrade I received late October. For my Vista system I successfully set-up last Summer a multi-partitions scheme with Users and Program Data on a a different partition than the operating system (see link below, and its subsequent links in my comment for details). http://tuts4tech.net/2009/08/05/windows-7-move-the-users-and-program-files-directories-to-a-different-partition/comment-page-1/#comment-562 I was planning a similar set-up for windows 7, a little more streamlined, with OS, Program Files on C:, Users and Program Data on D:, and TV media recording on a separate partition. Reading the Question submitted by Benjol, I am second guessing too. Is moving Users and Program Data on a different partition than the default primary partition with OS and Program Files such a good idea? The couple of people I talked to at the official Microsoft Windows 7 booth at CES 2010 gave the same answer to the intention of moving the Users profile folder to another partition. In a nutshell, they all told me that they used to do this in XP and less in Vista but not anymore with Windows 7... "It is stable, after two months still no problem" I had the feeling it was a scripted answer to emphasize how Windows 7 is so stable and efficient... (Will Windows-7 system not become bugged down over the course of several months to a year or two? Only time will tell) Long story short, I share the same view than Benjol expressed with respect to being "able to backup and restore system and user data independently." I just received a 2TB usb2, eSATA external hard drive as a back-up drive, which includes NTI Shadow 4 (4.1.0.150) for back-up solution. I took note of the issue with NTUSER.DAT and I will read more about Volume Shadow Copy Service (VSS) for Windows 7. I am willing to put the effort if placing Users and Program Data on a different partition would allow to restore a fresher OS+Program image when the system gets bugged down. Questions: Is it such a bad idea? What is the "easy route" referred by Benjol in his post? Is it to just relocate folders to another partition using the Folder property tool? (It is not practical for several users and might not provide a straightforward restore process of just OS and Program Files when needed.) I am starting to learn about Windows 7 libraries. Would Windows 7 libraries be another alternative to achieve this? All this reading to decide how to organize the partition scheme for my custom system is starting to be confusing. I apologize for this lengthy Question. It is my first day here on SuperUser and I am just learning how different from a discussion thread it is. Thank you in advance for all your suggestions and comments. Donat

    Read the article

< Previous Page | 310 311 312 313 314 315 316 317 318 319 320 321  | Next Page >