Search Results

Search found 6339 results on 254 pages for 'josh 24 2'.

Page 33/254 | < Previous Page | 29 30 31 32 33 34 35 36 37 38 39 40  | Next Page >

  • DHCP forwarding behind access list on a Cisco Catalyst

    - by Ásgeir Bjarnason
    I'm having some trouble with forwarding DHCP from a subnet behind an access list on a Cisco Catalyst 4500 switch. I'm hoping somebody can see the mistake I'm making. The subnet is defined like this: (first three octets of IP addresses and vrf name anonymized) interface Vlan40 ip vrf forwarding vrf_name ip address 10.10.10.126 255.255.255.0 secondary ip address 10.10.10.254 255.255.255.0 ip access-group 100 out ip helper-address 10.10.20.36 no ip redirects I tried turning on a VMWare machine on this subnet that was configured to use DHCP, but I never got a DHCP response and the DHCP server didn't receive a request. I tried putting the following in the access-list: access-list 100 permit udp host 10.10.10.254 host 10.10.20.36 eq bootps access-list 100 permit udp host 10.10.10.254 host 10.10.20.36 eq bootpc access-list 100 permit udp host 10.10.20.36 host 10.10.10.254 eq bootps access-list 100 permit udp host 10.10.20.36 host 10.10.10.254 eq bootpc That didn't help. Can anybody see what the problem is? I know that the DHCP server works; our whole network is running off of this DHCP server I also know that the subnet works because we have active servers running on the network The DHCP scope is already defined on the DHCP server The subnet is correctly defined on the VMWare server (already servers running on the subnet on VMWare) Edit 2012-10-19: This is solved! The subnet had formerly been defined as a /25 network, but was then expanded into a /24 network. When the DHCP scope was altered after this change it was done incorrectly; the gateway was moved to .254, the leasable IP range was in the lower half of the /24 subnet but we forgot to change the CIDR prefix from /25 into /24. This happened some 2 years ago, and we didn't need to use DHCP on this server network again until this week. Thank you MDMarra and Jason Seemann for looking at the question and trying to troubleshoot. Now I'm wondering if I should mark Jason's answer as the accepted answer (I am new to the Stack Exchange network, so I don't know the etiquette of what to do if I misstated the question like in this case).

    Read the article

  • Apache HTTPD - Segmentation fault when loading mod_jk module

    - by Hans Engel
    I just set up mod_jk with my Apache httpd 2.0.52 installation, but now when I try to start Apache, it has a segmentation fault. I've checked that I am using the mod_jk compiled for 2.0.x.. built against the same version I have, in fact. I've also verified that the path I'm giving to LoadModule is correct, and the permissions and the ownership of the file are the same as the rest of the modules'. When I remove the "LoadModule" command for mod_jk from my httpd.conf, there is no segmentation fault. Nothing shows in Apache's error logs. I have tried restarting the server with this module using both service httpd restart and httpd. These are the last few lines returned of strace httpd -X: gettimeofday({1292100295, 434487}, NULL) = 0 socket(PF_INET6, SOCK_STREAM, IPPROTO_IP) = -1 EAFNOSUPPORT (Address family not supported by protocol) socket(PF_NETLINK, SOCK_RAW, 0) = 3 bind(3, {sa_family=AF_NETLINK, pid=0, groups=00000000}, 12) = 0 getsockname(3, {sa_family=AF_NETLINK, pid=22378, groups=00000000}, [12]) = 0 time(NULL) = 1292100295 sendto(3, "\24\0\0\0\26\0\1\3\307\342\3M\0\0\0\0\0\305\333\267", 20, 0, {sa_family=AF_NETLINK, pid=0, groups=00000000}, 12) = 20 recvmsg(3, {msg_name(12)={sa_family=AF_NETLINK, pid=0, groups=00000000}, msg_iov(1)=[{"<\0\0\0\24\0\2\0\307\342\3MjW\0\0\2\10\200\376\1\0\0\0"..., 4096}], msg_controllen=0, msg_flags=0}, 0) = 664 recvmsg(3, {msg_name(12)={sa_family=AF_NETLINK, pid=0, groups=00000000}, msg_iov(1)=[{"\24\0\0\0\3\0\2\0\307\342\3MjW\0\0\0\0\0\0\1\0\0\0\10\0"..., 4096}], msg_controllen=0, msg_flags=0}, 0) = 20 close(3) = 0 socket(PF_INET, SOCK_STREAM, IPPROTO_IP) = 3 --- SIGSEGV (Segmentation fault) @ 0 (0) --- +++ killed by SIGSEGV +++ Process 22378 detached Has anyone had a similar problem using Apache 2.0.52 with mod_jk? I might try downloading and building the source for the Apache server and mod_jk myself if there isn't a discovered fix for this.

    Read the article

  • How can I bridge a VM to a remote network?

    - by asciiphil
    I have a system running QEMU/KVM (via libvirt). One of its VMs needs to have a presence on a subnet that is not local to the VM host. I have a Linux system on the remote subnet. Is there a way to set up some sort of tunneled bridge to cause the VM to appear present on the remote system? This will be a temporary situation (hopefully just until the VM owner can configure their system) and network performance and long-term maintainability aren't really issues. To give some more concrete information: My VM host has IP address 192.168.54.155/24. The VM has IP address 192.168.65.71/24. I have a remote system at 192.168.65.254/24. Both the VM host and remote system are running Scientific Linux 6.5. I do not control the network or routing in between the VM host and remote system. I do not have access to the guest OS on the VM. I would like traffic to the VM's IP address to end up at the VM even though its host isn't directly connected to the appropriate network. I've tried using iproute2's tunnelling, but Linux won't let me add a tunnel to a bridge. I've considered using some sort of iptables mangling to route traffic over the tunnel and make the VM think it's on the right network, but I'm not sure whether there are better approaches. What's the best way to accomplish this hack?

    Read the article

  • nameserver spoiling avahi multicast name resolution of .local domain

    - by Doug Coburn
    After trying to ping a machine on my local network, I noticed that I was trying hit address 66.152.109.24. This is an external public address. Resolution should have occurred via avahi mDNS. I ran dig to see how the name resolution worked and my quest/centurylink name server was retuning results for my .local domain queries! I tried a random name and got the same ip address result. $ dig jakdafj.local ; <<>> DiG 9.8.1-P1-RedHat-9.8.1-3.P1.fc15 <<>> jakdafj.local ;; global options: +cmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 58410 ;; flags: qr rd ra; QUERY: 1, ANSWER: 2, AUTHORITY: 0, ADDITIONAL: 0 ;; QUESTION SECTION: ;jakdafj.local. IN A ;; ANSWER SECTION: jakdafj.local. 10 IN A 66.152.109.24 jakdafj.local. 10 IN A 204.232.231.46 ;; Query time: 104 msec ;; SERVER: 205.171.3.25#53(205.171.3.25) ;; WHEN: Sat Mar 24 20:40:17 2012 ;; MSG SIZE rcvd: 63 Am I missing something or is my DNS name server at 205.171.3.25 corrupted?

    Read the article

  • help with xorg.conf: xrandr on one of two widescreen monitors; rhel5, kde, ATI Radeon X1300

    - by user35997
    Can anyone help with me configure my dual-screen monitors for rotation? I have xrandr 1.1. Have tried various approaches, nothing takes. I can't even get the xrandr options to show up in KDE's Display control panel. Thanks1 My lspci output: 03:00.0 VGA compatible controller: ATI Technologies Inc RV516 [Radeon X1300/X1550 Series] My current xorg.conf (works, minus screen rotation): # Xorg configuration created by system-config-display Section "ServerLayout" Identifier "Multihead layout" Screen 0 "aticonfig-Screen[0]" 0 0 InputDevice "Keyboard0" "CoreKeyboard" Option "Xinerama" "off" Option "Clone" "on" EndSection Section "Files" EndSection Section "Module" EndSection Section "InputDevice" Identifier "Keyboard0" Driver "kbd" Option "XkbModel" "pc105" Option "XkbLayout" "us" EndSection Section "Monitor" ### Comment all HorizSync and VertSync values to use DDC: Identifier "Monitor1" VendorName "Monitor Vendor" ModelName "Dell 2407WFP (Digital)" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 76.0 Option "dpms" EndSection Section "Monitor" Identifier "aticonfig-Monitor[0]" Option "VendorName" "ATI Proprietary Driver" Option "ModelName" "Generic Autodetecting Monitor" Option "DPMS" "true" EndSection Section "Device" Identifier "Videocard0" Driver "vesa" EndSection Section "Device" Identifier "Videocard1" Driver "vesa" VendorName "Videocard Vendor" BoardName "ATI Technologies Inc RV516 [Radeon X1300/X1550 Series]" BusID "PCI:3:0:0" EndSection Section "Device" Identifier "aticonfig-Device[0]" Driver "fglrx" Option "DesktopSetup" "horizontal" EndSection Section "Screen" Identifier "Screen0" Device "Videocard0" DefaultDepth 16 SubSection "Display" Viewport 0 0 Depth 24 EndSubSection SubSection "Display" Viewport 0 0 Depth 16 EndSubSection EndSection Section "Screen" Identifier "Screen1" Device "Videocard1" Monitor "Monitor1" DefaultDepth 16 SubSection "Display" Viewport 0 0 Depth 16 Modes "1920x1200" "1280x1024" "800x600" EndSubSection EndSection Section "Screen" Identifier "aticonfig-Screen[0]" Device "aticonfig-Device[0]" Monitor "aticonfig-Monitor[0]" DefaultDepth 24 SubSection "Display" Viewport 0 0 Depth 24 Modes "1920x1200" "1280x1024" "800x600" EndSubSection EndSection

    Read the article

  • virtualbox snapshot size

    - by intuited
    I've started using Windows 7 under VirtualBox on an Ubuntu 10.10 host. I took about 6 snapshots over the course of setting up the VM from the Windows restore image that came with the computer. My installations were more or less limited to windows updates, antivirus, and the VB Guest Additions. I uninstalled much more than I installed. The VM was running for about 24 hours total. The snapshots increased in size at a worrisome rate, even when the machine was idle: the snapshot .vdi file for the period between 11:22 PM and 9:02 AM is 6 gigs in size; during that time very little happened. The other .vdi files are between 0.5 and 3 GB, most between 1 and 2 GB. The corresponding .sav files are between 0.5 and 1 GB. The Internet connection where I was doing this is limited to 30KB/s download, which, constantly saturated, works out to less than 3 GB per 24 hour period. Is this normal? Is there something that can be done to make snapshots more practical? update On starting up the VM again, I've noticed that mscorsvw is using significant processing time. Apparently this process [precompiles .NET assemblies]. This may have been going on during the period when I was taking snapshots, which might explain some of the snapshot size increase. I would be somewhat surprised to learn that this could be responsible for over 10 GB of additional disk usage, or that it would run for roughly 24 hours. Is this possible?

    Read the article

  • Configuring vlans on Cisco SG200 series switch with Ubuntu server

    - by nixnotwin
    I created a vlan on Ubuntu with vconfig tool with 21 as id and eth1 as the host port. I connected eth1 to one of the ports on the swtich (GE23) as all ports trunk by default. In the webgui I created a vlan named test with the id 21 and I made GE2 are port as an access port. In port to vlan mapping I selected vlan 21 and added it port GE2 by selecting untagged option. I have assigned 192.168.1.1/24 as the ip of eth1.21 on Ubuntu. If I connect another cleint pc to GE2 port with a ip of 192.168.1.2/24 I cannot ping the server ip (192.168.1.1/24). Ping from server to client also does not work. I inspected packets that are sent out eth1 on the server and I could see the vlan 21 tag. And I connect the other end of the cable to a different Linux pc and inspected the packets but no vlan tags can be seen. What could be preventing me from getting vlans working? Edit 1 screenshots:

    Read the article

  • Karmic iptables missing kernel moduyles on OpenVZ container

    - by luison
    After an unsuccessful p2v migration of my Ubuntu server to an OpenVZ container which I am stack with I thought I would give a try to a reinstall based on a clean OpenVZ template for Ubuntu 9.10 (from the OpenVZ wiki) When I try to load my iptables rules on the VM machine I've been getting errors which I believe are related to kernel modules not being loaded on the VM from the /vz/XXX.conf template model. I've been testing with a few post I've found but I was stack with the error: WARNING: Deprecated config file /etc/modprobe.conf, all config files belong into /etc/modprobe.d/. FATAL: Could not load /lib/modules/2.6.24-10-pve/modules.dep: No such file or directory iptables-restore v1.4.4: iptables-restore: unable to initialize table 'raw' Error occurred at line: 2 Try `iptables-restore -h' or 'iptables-restore --help' for more information. I read about the template not loading all iptables modules so I added modules to the XXX.conf of the VZ virtual machine like this: IPTABLES="ip_tables iptable_filter iptable_mangle ipt_limit ipt_multiport ipt_tos ipt_TOS ipt_REJECT ipt_TCPMSS ipt_tcpmss ipt_ttl ipt_LOG ipt_length ip_conntrack ip_conntrack_ftp ip_conntrack_irc ipt_conntrack ipt_state ipt_helper iptable_nat ip_nat_ftp ip_nat_irc" As the error remained I read that I should build dependencies again on the virtual machine: depmod -a but this returned an error: WARNING: Couldn't open directory /lib/modules/2.6.24-10-pve: No such file or directory FATAL: Could not open /lib/modules/2.6.24-10-pve/modules.dep.temp for writing: No such file or directory So I read again about creating the directory empty and redoing "depmod -a" it. I now don't get the dependancies error but get this and I don't have a clue how to proceed: WARNING: Deprecated config file /etc/modprobe.conf, all config files belong into /etc/modprobe.d/. FATAL: Module ip_tables not found. iptables-restore v1.4.4: iptables-restore: unable to initialize table 'raw' Error occurred at line: 2 Try `iptables-restore -h' or 'iptables-restore --help' for more information. I understand that iptables rules have to be different on the VM machine and perhaps some of the rules we are trying to apply (from our physical server) are not compatible but these are just source IP and destination port checks that I would like to be able to have available . I've heard that on the CentOS template there are no issues with this, so I understand is to do with VM config. Any help would be greatly appreciated.

    Read the article

  • Raid-5 Performance per spindle scaling

    - by Bill N.
    So I am stuck in a corner, I have a storage project that is limited to 24 spindles, and requires heavy random Write (the corresponding read side is purely sequential). Needs every bit of space on my Drives, ~13TB total in a n-1 raid-5, and has to go fast, over 2GB/s sort of fast. The obvious answer is to use a Stripe/Concat (Raid-0/1), or better yet a raid-10 in place of the raid-5, but that is disallowed for reasons beyond my control. So I am here asking for help in getting a sub optimal configuration to be as good as it can be. The array built on direct attached SAS-2 10K rpm drives, backed by a ARECA 18xx series controller with 4GB of cache. 64k array stripes and an 4K stripe aligned XFS File system, with 24 Allocation groups (to avoid some of the penalty for being raid 5). The heart of my question is this: In the same setup with 6 spindles/AG's I see a near disk limited performance on the write, ~100MB/s per spindle, at 12 spindles I see that drop to ~80MB/s and at 24 ~60MB/s. I would expect that with a distributed parity and matched AG's, the performance should scale with the # of spindles, or be worse at small spindle counts, but this array is doing the opposite. What am I missing ? Should Raid-5 performance scale with # of spindles ? Many thanks for your answers and any ideas, input, or guidance. --Bill Edit: Improving RAID performance The other relevant thread I was able to find, discusses some of the same issues in the answers, though it still leaves me with out an answer on the performance scaling.

    Read the article

  • Connecting to MySQL Server from PHP Command Line (MAMP)

    - by Austin White
    First of all, I'm using Mac OSX 1.6, MAMP 1.9, PHP 5.3.4, and MySQL 5.1.44. I'm in the process of setting up a video encoding service for a site using Chris Boulton's PHP-Resque and Redis. Once the worker process is fired and the videos have been encoded, I need to save their locations to a mysql database. The php script is being run from the shell, so that is where the issue begins. I import the mysql settings and when it attempts to connect, I get the following errors: Warning: mysqli::mysqli(): php_network_getaddresses: getaddrinfo failed: nodename nor servname provided, or not known in /Users/austingym/Documents/Dropbox/Website/htdocs/homefree/lib/MySQLi_Extended.class.php on line 24 Warning: mysqli::mysqli(): [2002] php_network_getaddresses: getaddrinfo failed: nodename nor servn (trying to connect via tcp://MYSQL_SERVER:3306) in /Users/austingym/Documents/Dropbox/Website/htdocs/homefree/lib/MySQLi_Extended.class.php on line 24 Warning: mysqli::mysqli(): (HY000/2002): php_network_getaddresses: getaddrinfo failed: nodename nor servname provided, or not known in /Users/austingym/Documents/Dropbox/Website/htdocs/homefree/lib/MySQLi_Extended.class.php on line 24 Warning: mysqli::set_charset(): Couldn't fetch MySQLi_Extended in /Users/austingym/Documents/Dropbox/Website/htdocs/homefree/lib/MySQLi_Extended.class.php on line 32 I realize that the error is occurring because it's trying to connect to tcp://MYSQL_SERVER:3306, when MySQL is on port 8889. I've been reading about Mac OSX and MAMP errors regarding the mysql.sock and I've gone through multiple forums and tried various fixes, but none have worked. I've tried PATH=/Applications/MAMP/Library/bin/:/Applications/MAMP/bin/php5.3/bin/:/opt/local/bin:/opt/local/sbin:$PATH and sudo ln -s /Applications/MAMP/tmp/mysql/mysql.sock /tmp/mysql.sock but neither have worked. I even ran a search on my machine for "3306" to find where it's being set, but because that's the normal default, I'm guessing it's not being set explicitly. Any clues on how to fix this rather challenging error?

    Read the article

  • mysqld-nt.exe exist in task list, but actually it's not running?

    - by PHP
    mysqld-nt.exe is showing in the task manager, but I cannot connect to it. I tried: telnet localhost 3306 And it fails to connect. So I restarted the server,and it's ok. This happens every day. Any ideas? EDIT Here is the error log(I didn't find anything abnormal though): 100122 10:11:16 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: Normal shutdown 100122 10:11:16 InnoDB: Starting shutdown... 100122 10:11:18 InnoDB: Shutdown completed; log sequence number 0 22939338 100122 10:11:18 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: Shutdown complete 100122 10:12:40 InnoDB: Started; log sequence number 0 22939338 100122 10:12:42 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: ready for connections. Version: '5.0.24-community-nt' socket: '' port: 3306 MySQL Community Edition (GPL) 100123 16:20:44 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: Normal shutdown 100123 16:20:44 InnoDB: Starting shutdown... 100123 16:20:46 InnoDB: Shutdown completed; log sequence number 0 22939832 100123 16:20:46 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: Shutdown complete 100123 16:22:09 InnoDB: Started; log sequence number 0 22939832 100123 16:22:11 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: ready for connections. Version: '5.0.24-community-nt' socket: '' port: 3306 MySQL Community Edition (GPL) 100125 9:18:59 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: Normal shutdown 100125 9:18:59 InnoDB: Starting shutdown... 100125 9:19:00 InnoDB: Shutdown completed; log sequence number 0 22941001 100125 9:19:00 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: Shutdown complete 100125 9:20:22 InnoDB: Started; log sequence number 0 22941001 100125 9:20:25 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: ready for connections. Version: '5.0.24-community-nt' socket: '' port: 3306 MySQL Community Edition (GPL)

    Read the article

  • X11 performance problem after upgrading from Centos3 to Centos5 with an ATI Rage XL

    - by Marcelo Santos
    After upgrading a computer from Centos3 to Centos5 an application that does a lot of scrolling took a very high performance hit. top tells me that X is using a lot of CPU and that was not happening before. The machine has an ATI Rage XL with 8MB and X is using the ati driver as there is no proprietary ATI driver for this board on linux. The xorg.conf: Section "Device" Identifier "Videocard0" Driver "ati" EndSection Section "Screen" Identifier "Screen0" Device "Videocard0" DefaultDepth 24 SubSection "Display" Viewport 0 0 Depth 24 Modes "1024x768" "800x600" "640x480" EndSubSection EndSection Section "DRI" Group 0 Mode 0666 EndSection A similar machine that still has Centos3 installed is able to start DRI on the X server while this one is not, this is the Xorg.0.log for the Centos5 machine: drmOpenDevice: node name is /dev/dri/card0 drmOpenDevice: open result is -1, (No such device or address) drmOpenDevice: open result is -1, (No such device or address) drmOpenDevice: Open failed drmOpenDevice: node name is /dev/dri/card0 drmOpenDevice: open result is -1, (No such device or address) drmOpenDevice: open result is -1, (No such device or address) drmOpenDevice: Open failed [drm] failed to load kernel module "mach64" (II) ATI(0): [drm] drmOpen failed (EE) ATI(0): [dri] DRIScreenInit Failed (II) ATI(0): Largest offscreen areas (with overlaps): (II) ATI(0): 1024 x 1279 rectangle at 0,768 (II) ATI(0): 768 x 1280 rectangle at 0,768 (II) ATI(0): Using XFree86 Acceleration Architecture (XAA) Screen to screen bit blits Solid filled rectangles 8x8 mono pattern filled rectangles Indirect CPU to Screen color expansion Solid Lines Offscreen Pixmaps Setting up tile and stipple cache: 32 128x128 slots 10 256x256 slots (==) ATI(0): Backing store disabled (==) ATI(0): Silken mouse enabled (II) ATI(0): Direct rendering disabled (==) RandR enabled I also tried using EXA instead of XAA and setting: Option "AccelMethod" "XAA" Option "XAANoOffscreenPixmaps" "true" uname -a Linux sir5.erg.inpe.br 2.6.18-128.7.1.el5 #1 SMP Mon Aug 24 08:20:55 EDT 2009 i686 i686 i386 GNU/Linux rpm -qa | grep xorg-x11-server xorg-x11-server-utils-7.1-4.fc6 xorg-x11-server-sdk-1.1.1-48.52.el5 xorg-x11-server-Xvfb-1.1.1-48.52.el5 xorg-x11-server-Xnest-1.1.1-48.52.el5 xorg-x11-server-Xorg-1.1.1-48.52.el5 The drmOpenDevice error continues when using the suggested Option "AIGLX" "true".

    Read the article

  • Unable to connect to cable modem when connected to VPN

    - by Spuas
    the scenario is as follows: First I have a cable modem which gives the internet connection. The network is 192.168.0.0/24 and its IP is 192.168.0.1 Second line, I have a router connected to the cable modem. Its "outside" IP is 192.168.0.12. This router creates network 192.168.123.0/24 and its IP there is 192.168.123.254. My computer is wired to the router with IP 192.168.123.126. At this point I am able to access both devices web interfaces by their IPs on a browser (192.168.123.254 for the router and 192.168.0.1 for the cable modem). The problem I have is when I connect to a VPN from the computer. Then I am connected to a second network 10.0.0.0/24 and I get IP 10.0.0.200 (along with 192.168.123.126). I can connect to the router but then I loose connectivity to the cable modem: I cannot acces it through the browser, neither making a ping to it or a tracert. I have tried to add a new route to the windows routes by typing route ADD 192.168.0.1 MASK 255.255.255.0 192.168.123.254 but I cannot access it anyway... Am I missing something on the route adding? Which is the propper way of doing this? Thanks

    Read the article

  • Karmic iptables missing kernel moduyles on OpenVZ container

    - by luison
    After an unsuccessful p2v migration of my Ubuntu server to an OpenVZ container which I am stack with I thought I would give a try to a reinstall based on a clean OpenVZ template for Ubuntu 9.10 (from the OpenVZ wiki) When I try to load my iptables rules on the VM machine I've been getting errors which I believe are related to kernel modules not being loaded on the VM from the /vz/XXX.conf template model. I've been testing with a few post I've found but I was stack with the error: WARNING: Deprecated config file /etc/modprobe.conf, all config files belong into /etc/modprobe.d/. FATAL: Could not load /lib/modules/2.6.24-10-pve/modules.dep: No such file or directory iptables-restore v1.4.4: iptables-restore: unable to initialize table 'raw' Error occurred at line: 2 Try `iptables-restore -h' or 'iptables-restore --help' for more information. I read about the template not loading all iptables modules so I added modules to the XXX.conf of the VZ virtual machine like this: IPTABLES="ip_tables iptable_filter iptable_mangle ipt_limit ipt_multiport ipt_tos ipt_TOS ipt_REJECT ipt_TCPMSS ipt_tcpmss ipt_ttl ipt_LOG ipt_length ip_conntrack ip_conntrack_ftp ip_conntrack_irc ipt_conntrack ipt_state ipt_helper iptable_nat ip_nat_ftp ip_nat_irc" As the error remained I read that I should build dependencies again on the virtual machine: depmod -a but this returned an error: WARNING: Couldn't open directory /lib/modules/2.6.24-10-pve: No such file or directory FATAL: Could not open /lib/modules/2.6.24-10-pve/modules.dep.temp for writing: No such file or directory So I read again about creating the directory empty and redoing "depmod -a" it. I now don't get the dependancies error but get this and I don't have a clue how to proceed: WARNING: Deprecated config file /etc/modprobe.conf, all config files belong into /etc/modprobe.d/. FATAL: Module ip_tables not found. iptables-restore v1.4.4: iptables-restore: unable to initialize table 'raw' Error occurred at line: 2 Try `iptables-restore -h' or 'iptables-restore --help' for more information. I understand that iptables rules have to be different on the VM machine and perhaps some of the rules we are trying to apply (from our physical server) are not compatible but these are just source IP and destination port checks that I would like to be able to have available . I've heard that on the CentOS template there are no issues with this, so I understand is to do with VM config. Any help would be greatly appreciated.

    Read the article

  • OpenVPN with MacOS X Client and same subnets in local and remote net.

    - by Daniel
    I have a homenetwork 192.168.1.0/24 with gteway 192.168.1.1 and a remote network with the same parameters. Now I want to create a OpenVPN tunnel between those networks. I have no problems with Windows, because Windows routes everything to 192.168.1.0/24 except 192.168.1.1 throught the tunnel. On MacOS X however I see the folling line in the Details window: 2010-05-10 09:13:01 WARNING: potential route subnet conflict between local LAN [192.168.1.0/255.255.255.0] and remote VPN [192.168.1.0/255.255.255.0] When I list the routes I get the following: Internet: Destination Gateway Flags Refs Use Netif Expire default 192.168.1.1 UGSc 13 3 en1 127 localhost UCS 0 0 lo0 localhost localhost UH 12 3589 lo0 169.254 link#5 UCS 0 0 en1 192.168.1 link#5 UCS 1 0 en1 192.168.1.1 0:1e:e5:f4:ec:7f UHLW 13 17 en1 1103 192.168.1.101 localhost UHS 0 0 lo0 192.168.6 192.168.6.5 UGSc 0 0 tun0 192.168.6.5 192.168.6.6 UH 1 0 tun0 My Interfaces are en1 - My local Wifi network tun0 - The tunnel interface As can be seen from the routes above there is no entry for 192.168.1.0/24 that routes the traffic through the tunnel interface. When I manually route a single IP like 192.168.1.16 over the tunnel gateway 192.168.6.6, this works. Q: How do I set up my routes in MacOS X for the same behaviour as on windows, to route everything except 192.168.1.1 through the tunnel, but leave the default gateway to be my local 192.168.1.1 ?

    Read the article

  • MySQL password changed every other day in windows?

    - by PHP
    Every morning when I check server status,I will find MySQL's password is changed: mysql -uuser -ppassword will report ERROR 1045 (28000): Access denied for user 'user'@'localhost' (using password: YES) And then I restart server,and when it's up,MySQL will be back to normal. It has now become a routinely job. What can be the cause for this? How can I know what's exactly happening to MySQL? Here is the error log: 100122 10:11:16 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: Normal shutdown 100122 10:11:16 InnoDB: Starting shutdown... 100122 10:11:18 InnoDB: Shutdown completed; log sequence number 0 22939338 100122 10:11:18 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: Shutdown complete 100122 10:12:40 InnoDB: Started; log sequence number 0 22939338 100122 10:12:42 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: ready for connections. Version: '5.0.24-community-nt' socket: '' port: 3306 MySQL Community Edition (GPL) 100123 16:20:44 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: Normal shutdown 100123 16:20:44 InnoDB: Starting shutdown... 100123 16:20:46 InnoDB: Shutdown completed; log sequence number 0 22939832 100123 16:20:46 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: Shutdown complete 100123 16:22:09 InnoDB: Started; log sequence number 0 22939832 100123 16:22:11 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: ready for connections. Version: '5.0.24-community-nt' socket: '' port: 3306 MySQL Community Edition (GPL) 100125 9:18:59 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: Normal shutdown 100125 9:18:59 InnoDB: Starting shutdown... 100125 9:19:00 InnoDB: Shutdown completed; log sequence number 0 22941001 100125 9:19:00 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: Shutdown complete 100125 9:20:22 InnoDB: Started; log sequence number 0 22941001 100125 9:20:25 [Note] D:\MySQL\MySQL Server 5.0\bin\mysqld-nt: ready for connections. Version: '5.0.24-community-nt' socket: '' port: 3306 MySQL Community Edition (GPL)

    Read the article

  • Do you really need cable management for a cabinet with just switches and patch panels?

    - by ObligatoryMoniker
    We are about to start wiring out a building expansion and our vendor has laid out the racks in the following configuration: Option 1 1U Fiber patch panel 2U Cable Manager 2U 48 port Patch Panel 2U Cable Manager 2U 48 port Patch Panel 2U Cable Manager 1U 48 port Switch 2U Cable Manager 1U 48 port Switch Total = 15U All the patch panels would be connected to the switches with 1ft+ cables fed through cable management. What I am considering instead is: Option 2 1U Fiber patch panel 1U 24 port Patch Panel 1U 48 port Switch 2U 48 port Patch Panel 1U 48 port Switch 2U 48 port Patch Panel Total = 8U All of the patch panels would be connected to the switches with .5 ft cables directly on their face with the top 24 ports of each switch patched to the patch panel above it and the bottom 24 ports of each switch patched to the patch panel beneath it which would not require any cable management. If I go with option 2 it save all of the space used by cable management and allows us to keep adding on switches and patch panels at the end without having to re-cable all of the patch panels above. Our vendor has indicated that this is not best practice and that .5ft cables will introduce cross talk. I could understand that being the case if we were connecting the .5 ft cable directly into another switch but we are connecting it to a patch panel that likely has another 150 ft cable run from the back of the patch panel out to the port in the building in which case the real resulting cable is 150.5 ft at minimum before even connecting it to a PC. It seems like it makes much more sense to go with option 2. It is easier to expand, saves space, and saves money on cabling and cable management. Does this kind of configuration make sense or is there a legitimate reason to choose Option 1 over Option 2?

    Read the article

  • PHP script not automatically updating when moved to another server

    - by user32007
    A friend built a ranking system on his site and I am trying to host in on mine via WordPress and Go Daddy. It updates for him but when I load it to my site, it works for 6 hours, but as soon as the reload is supposed to occur, it errors and I get a 500 timeout error. His page is at: jeremynoeljohnson .com/yakezieclub My page is currently at http://sweatingthebigstuff.com/yakezieclub but when you ?reload=1 it will give the error. Any idea why this might be happening? Any settings that I might need to change? Here is the top of the index.php file. I'm not sure which part of any of it is messing up. I literally uploaded the same code as him. Here's the reload part: $cachefile = "rankings.html"; $daycachefile = "rankings_history.xml"; $cachetime = (60 * 60) * 6; // every 6 hours, the cache refreshes $daycachetime = (60 * 60) * 24; // every 24 hours, the history will be written to // - or whenever the page is requested after 24 hours has passed $writenewdata = false; if (!empty($_GET['reload'])) { if ($_GET['reload']== 1) { $cachetime = 1; } } if (!empty($_GET['reloadhistory'])) { if ($_GET['reloadhistory'] == 1) { $daycachetime = 1; $cachetime = 1; } } if (file_exists($daycachefile) && (time() - $daycachetime < filemtime($daycachefile))) { // Do nothing } else { $writenewdata = true; $cachetime = 1; } // Serve from the cache if it is younger than $cachetime if (file_exists($cachefile) && (time() - $cachetime < filemtime($cachefile))) { include($cachefile); echo "<!-- Cached ".date('jS F Y H:i', filemtime($cachefile))." -->"; exit; } ob_start(); // start the output buffer ?>

    Read the article

  • Display with intel integrated graphics, bitcoin mine with Radeon 6950

    - by karategeek6
    I'm on Ubuntu Linux 11.04 64 bit. I have an intel i5 with integrated graphics and a Radeon 6950, with one monitor. I would like to run my graphics on the integrated card, and run bitcoin mining on the 6950. I have bitcoin mining working when I use the 6950 for both display and mining. Every time I try and and use the integrated graphics instead, OpenCL doesn't recognize my 6950. Using aticonfig --initial when using the integrated graphics for display breaks things. So I used the xorg.conf it created as a basis and tried to manually edit it. I really don't know what I'm doing, though. My last attempt is given below. The graphics ran off the integrated card, but the 6950 wasn't recognized. Any help would be greatly appreciated! xorg.conf: #Section "ServerLayout" # Identifier "Intel Layout" # Screen "Default Screen" # Identifier "aticonfig Layout" # Screen "aticonfig-Screen[0]-0" # Screen 0 "aticonfig-Screen[0]-0" 0 0 #EndSection Section "Module" Load "glx" EndSection # Intel Section "Device" Identifier "Intel Integrated Graphics" Driver "intel" BusID "PCI:0:2:0" EndSection Section "Monitor" Identifier "Default Monitor" Option "VendorName" "Monitor Vendor" Option "ModelName" "Monitor Name" Option "DPMS" "true" EndSection Section "Screen" Identifier "Default Screen" Device "Intel Integrated Graphics" Monitor "Default Monitor" DefaultDepth 24 EndSection # ATI Section "Device" Identifier "aticonfig-Device[0]-0" Driver "fglrx" BusID "PCI:1:0:0" EndSection Section "Monitor" Identifier "aticonfig-Monitor[0]-0" Option "VendorName" "ATI Proprietary Driver" Option "ModelName" "Generic Autodetecting Monitor" Option "DPMS" "true" EndSection Section "Screen" Identifier "aticonfig-Screen[0]-0" Device "aticonfig-Device[0]-0" Monitor "aticonfig-Monitor[0]-0" DefaultDepth 24 SubSection "Display" Viewport 0 0 Depth 24 EndSubSection EndSection

    Read the article

  • Same netmask or /32 for secondary IP on Linux

    - by derobert
    There appear to be (at least) two ways to add a secondary IP address to an interface on Linux. By secondary, I mean that it'll accept traffic to the IP address, and responses to connections made to that IP will use it as a source, but any traffic the box originates (e.g., an outgoing TCP connection) will not use the secondary address. Both ways start with adding the primary address, e.g., ip addr add 172.16.8.10/24 dev lan. Then I can add the secondary address with either a netmask of /24 (matching the primary) or /32. If I add it with a /24, it gets flagged secondary, so will not be used as the source of outgoing packets, but that leaves a risk of the two addresses being added in the wrong order by mistake. If I add it with /32, wrong order can't happen, but it doesn't get flagged as secondary, and I'm not sure what the bad effects of that may be. So, I'm wondering, which approach is least likely to break? (If it matters, the main service on this machine is MySQL, but it also runs NFSv3. I'm adding a second machine as a warm standby, and hope to switch between them by changing which owns the secondary IP.)

    Read the article

  • Single m0n0wall - Two LAN Subnets - How To Setup

    - by SnAzBaZ
    I have two LAN subnets that I need to link together they are 192.168.4.0/24 and 192.168.5.0/24 There is a m0n0wall running on 192.168.4.1. It's LAN connection goes out to our network switch, and it's WAN port goes out to our ADSL modem. WAN is connected via PPPoE. The 192.168.4.0 subnet contains all of our office workstations. The 192.168.5.0 subnet contains development servers and test machines that need to obtain internet access and be "managed" by computers on the 192.168.4.0 subnet, but need to be on their own subnet as well. I have a Draytek 2820N configured on 192.168.5.1 with it's WAN2 port configured as 192.168.4.25 and a default gateway of 192.168.4.1. Machines on the 5.0 subnet can connect to the internet via the m0n0wall just fine. I configured a static route on the m0n0wall LAN interface, Network 192.168.5.0/24 and Gateway 192.168.4.25. Machines on the 5.0 subnet can ping machines on the 4.0 network but the reverse does not work. I configured a new firewall rule on the m0n0wall that allows any traffic on the LAN interface with a source IP of 192.168.4.25 to be allowed. The DrayTek firewall is currently configured to pass all traffic regardless. When I try to ping a machine in the 5.0 subnet from 4.0 I see this in my m0n0wall log: BLOCK 14:45:27.888157 LAN 192.168.4.25 192.168.4.37, type echoreply/0 ICMP So the reply is being sent from the 5.0 subnet but is not being allowed to reach my workstation because the firewall is blocking it. Why is the firewall blocking it ? I hope the explanation of my network is clear, please ask if you require further clarification. Thank you.

    Read the article

  • VLAN ACLs and when to go Layer 3

    - by wuckachucka
    I want to: a) segment several departments into VLANs with the hopes of restricting access between them completely (Sales never needs to talk to Support's workstations or printers and vice-versa) or b) certain IP addresses and TCP/UDP ports across VLANS -- i.e. permitting the Sales VLAN to access the CRM Web Server in the Server VLAN on port 443 only. Port-wise, I'll need a 48-port switch and another 24-port switch to go with the two existing 24-port Layer 2 switches (Linksys); I'm looking at going with D-Links or HP Procurves as Cisco is out of our price range. Question #1: From what I understand (and please correct me if I'm wrong), if the Servers (VLAN10) and Sales (VLAN20) are all on the same 48-port switch (or two stacked 24-port switches), afaik, the switch "knows" what VLANs and ports each device belongs to and will switch packets between them; I can also apply ACLs to restrict access between VLANs at this point. Is this correct? Question #2: Now lets say that Support (VLAN30) is on a different switch (one of the Linksys) switches. I'm assuming I'll need to trunk (tag) switch #2's VLANs across to switch #1, so switch #1 sees switch #2's VLAN30 (and vice-versa). Once Switch #1 can "see" VLAN30, I'm assuming I can then apply ACLs as stated in Question #1. Is this correct? Question #3: Once Switch #1 can see all the VLANs, can I achieve the seemingly "Layer 3" ACL filtering of restricting access to Server VLAN on only certain TCP/UDP ports and IP addresses (say, only permitting 3389 to the Terminal Server, 192.168.10.4/32). I say "seemingly" because some of the Layer 2 switches mention the ability to restrict ports and IP addresses through the ACLs; I (perhaps mistakenly) thought that in order to have Layer 3 ACLs (packet filtering), I'd need to have at least one Layer 3 switch acting as a core router. If my assumptions are incorrect, at which point do you need a Layer 3 switch for inter-VLAN routing vs. inter-VLAN switching? Is it generally only when you need that higher-level packet filtering ability between your departments?

    Read the article

  • Can't route specific subnet thru VPN in ubuntu

    - by Disco
    I'm having issues routing traffic thru VPN. Here's my setup I have 3 hosts, let's call them A, B and Z B and Z have a VPN connection in the 10.10.10.x SUBNET A and B have a direct connection in the 10.10.12.x SUBNET I want to be able to route traffic from A to Z, like : A <= 10.10.12.254 [LAN] 10.10.12.111 => B <= 10.10.10.152 [VPN] 10.10.10.10 => Z On host B, i have set up ip_forwarding : net.ipv4.ip_forward = 1 and routing on host B: [root@hostA: ~]# ip route 10.10.10.10 dev ppp0 proto kernel scope link src 10.10.10.152 10.10.12.0/24 dev eth1 proto kernel scope link src 10.10.12.111 10.10.10.0/24 dev ppp0 scope link 169.254.0.0/16 dev eth1 scope link routing on host A: [root@hostA: ~]# ip route 10.10.10.0 via 10.10.12.111 dev eth1 10.10.12.0/24 dev eth1 proto kernel scope link src 10.10.12.254 169.254.0.0/16 dev eth1 scope link default via 192.168.1.1 dev eth0 But still not able to ping 10.10.10.10 from host A. Any idea ? I'm pulling my hairs out.

    Read the article

  • OpenVPN + iptables / NAT routing

    - by Mikeage
    Hi, I'm trying to set up an OpenVPN VPN, which will carry some (but not all) traffic from the clients to the internet via the OpenVPN server. My OpenVPN server has a public IP on eth0, and is using tap0 to create a local network, 192.168.2.x. I have a client which connects from local IP 192.168.1.101 and gets VPN IP 192.168.2.3. On the server, I ran: iptables -A INPUT -i tap+ -j ACCEPT iptables -A FORWARD -i tap+ -j ACCEPT iptables -t nat -A POSTROUTING -s 192.168.2.0/24 -o eth0 -j MASQUERADE On the client, the default remains to route via 192.168.1.1. In order to point it to 192.168.2.1 for HTTP, I ran ip rule add fwmark 0x50 table 200 ip route add table 200 default via 192.168.2.1 iptables -t mangle -A OUTPUT -j MARK -p tcp --dport 80 --set-mark 80 Now, if I try accessing a website on the client (say, wget google.com), it just hangs there. On the server, I can see $ sudo tcpdump -n -i tap0 tcpdump: verbose output suppressed, use -v or -vv for full protocol decode listening on tap0, link-type EN10MB (Ethernet), capture size 96 bytes 05:39:07.928358 IP 192.168.1.101.34941 > 74.125.67.100.80: S 4254520618:4254520618(0) win 5840 <mss 1334,sackOK,timestamp 558838 0,nop,wscale 5> 05:39:10.751921 IP 192.168.1.101.34941 > 74.125.67.100.80: S 4254520618:4254520618(0) win 5840 <mss 1334,sackOK,timestamp 559588 0,nop,wscale 5> Where 74.125.67.100 is the IP it gets for google.com . Why isn't the MASQUERADE working? More precisely, I see that the source showing up as 192.168.1.101 -- shouldn't there be something to indicate that it came from the VPN? Edit: Some routes [from the client] $ ip route show table main 192.168.2.0/24 dev tap0 proto kernel scope link src 192.168.2.4 192.168.1.0/24 dev wlan0 proto kernel scope link src 192.168.1.101 metric 2 169.254.0.0/16 dev wlan0 scope link metric 1000 default via 192.168.1.1 dev wlan0 proto static $ ip route show table 200 default via 192.168.2.1 dev tap0

    Read the article

  • How to reinstall bootloader after migration to SSD

    - by hijarian
    I must say, it was difficult to name this question. Basically, I need to properly reinstall the bootloader on my system, because I already have the working system disks for my OSes. The long story is this: I had the large slow HDD with Windows7 & Debian Wheezy dual-boot on it, perfectly bootable. Then, I ordered the SSD drive and prepared my system partitions to fit onto the much smaller SSD. I wanted the following schema: 128 GB Windows 24 GB / on Debian 86 GB /home on Debian Strange size for /home because there's no such thing as true 256GB disk drive. So, I've prepared such a partitions on my initial HDD and installed the new SSD and then I loaded the GParted live USB (can't remember now how it was really named), and then just copypasted the partitions from HDD to SSD. So, now I have the following partitions across the physical disks: SSD 128 GB copy of original Windows partition 24 GB copy of presumably Debian / 86 GB copy of presumably Debian /home HDD 128 GB Windows 24 GB / on Debian 86 GB /home on Debian ... several other partitions with non-system data ... And the behavior of the system right after the Ctrl+C, Ctrl+V in GParted was as follows: no GRUB, system boots right into the Windows on HDD. In BIOS settings are to boot from SSD first. I managed to create the Debian Testing installation USB and loaded it into the rescue mode, found that it identified my SSD as /dev/sda and installed the GRUB to the /dev/sda. Now my system loads the GRUB which lists both Windows and Debian. From HDD. So, I am now back into initial position. Please, how I should set up the GRUB so it'll load the OSes correctly from SSD? Should I fire up my Debian, fiddle with the GRUB's config and reinstall it again to the same place (at SSD)?

    Read the article

< Previous Page | 29 30 31 32 33 34 35 36 37 38 39 40  | Next Page >