Search Results

Search found 61797 results on 2472 pages for 'time wait'.

Page 33/2472 | < Previous Page | 29 30 31 32 33 34 35 36 37 38 39 40  | Next Page >

  • Why doesn't my NamedPipeServerStream wait??

    - by Frank Fella
    I'm working with a NamedPipeServerStream to communicate between two processes. Here is the code where I initialize and connect the pipe: void Foo(IHasData objectProvider) { Stream stream = objectProvider.GetData(); if (stream.Length > 0) { using (NamedPipeServerStream pipeServer = new NamedPipeServerStream("VisualizerPipe", PipeDirection.Out, 1, PipeTransmissionMode.Byte, PipeOptions.Asynchronous)) { string currentDirectory = Path.GetDirectoryName(Assembly.GetExecutingAssembly().Location); string uiFileName = Path.Combine(currentDirectory, "VisualizerUIApplication.exe"); Process.Start(uiFileName); if(pipeServer.BeginWaitForConnection(PipeConnected, this).AsyncWaitHandle.WaitOne(5000)) { while (stream.CanRead) { pipeServer.WriteByte((byte)stream.ReadByte()); } } else { throw new TimeoutException("Pipe connection to UI process timed out."); } } } } private void PipeConnected(IAsyncResult e) { } But it never seems to wait. I constantly get the following exception: System.InvalidOperationException: Pipe hasn't been connected yet. at System.IO.Pipes.PipeStream.CheckWriteOperations() at System.IO.Pipes.PipeStream.WriteByte(Byte value) at PeachesObjectVisualizer.Visualizer.Show(IDialogVisualizerService windowService, IVisualizerObjectProvider objectProvider) I would think that after the wait returns everything should be ready to go. If I use pipeServer.WaitForConnection() everything works fine, but hanging the application if the pipe doesn't connect is not an option.

    Read the article

  • playframework auto-test Jenkins CI wait for completion?

    - by notbrain
    I am trying to set up Jenkins CI for a playframework.org application but am having trouble properly launching play after the auto-test command is run. The tests all run fine, but it seems as though my script is launching both play auto-test and play start --%ci at the same time. When the play start --%ci command runs, it gets a pid and everything, but it's not running. FILE: auto-test.sh, jenkins runs this with execute shell #!/bin/bash # pwd is jenkins workspace dir # change into approot dir cd customer-portal; # kill any previous play launches if [ -e "server.pid" ] then kill `cat server.pid`; rm -rf server.pid; fi # drop and re-create the DB mysql --user=USER --password=PASS --host=HOSTNAME < ../setupdb.sql # auto-test the most recent build /usr/local/lib/play/play auto-test; # this is inadequate for waiting for auto-test to complete? # how to wait for actual process completion? # sleep 60; wait; # Conditional start based on tests # Launch normal on pass, test on fail # if [ -e "./test-result/result.passed" ] then /usr/local/lib/play/play start --%ci; exit 0; else /usr/local/lib/play/play test; exit 1; fi

    Read the article

  • java url connection, wait for data being sent through the outputstream

    - by Mateu
    I'm writting a java class that tests uploading speed connection to a server. I want to check how many data can be send in 5 seconds. I've written a class which creates a URL, creates a connection, and sends data trough the outPutStream. There is a loop where I writte data to the stream for 5 seconds. However I'm not able to see when data has been send (I writte data to the output stream, but data is not send yet). How can I wait untill data is really sent to the server? Here goes my code (which does not work): URL u = new URL(url) HttpURLConnection uc = (HttpURLConnection) u.openConnection(); uc.setDoOutput(true); uc.setDoInput(true); uc.setUseCaches(false); uc.setDefaultUseCaches(false); uc.setRequestMethod("POST"); uc.setRequestProperty("Content-Type", "application/octet-stream"); uc.connect(); st.start(); // Send the request OutputStream os = uc.getOutputStream(); //This while is incorrect cause it does not wait for data beeing sent while (st.getElapsedTime() < miliSeconds) { os.write(buffer); os.flush(); st.addSize(buffer.length); } os.close(); Thanks

    Read the article

  • recvfrom() return values in Stop-and-Wait UDP?

    - by mavErick
    I am trying to implement a Stop-and-Wait UDP client-server socket program in C. As known, there are basically three possible scenarios for Stop-and-Wait flow control. i.e., After transmitting a packet, the sender receives a correct ACK and thus starts transmitting the next packet; the sender receives an incorrect ACK and thus retransmits this packet; the sender receives no ACK within a TIMEOUT and thus retransmits this packet. My idea is to differentiate these three scenarios with the return value of recvfrom() on the sender side. For scenario 1&2: recvfrom() just returns the length of the received ACK. Since in my implementation the incorrect ACK is of the same length of the correct one, so I will have to go deeper and check the contents of the ACK. It's not a big deal. I know how to do. Problems come when I am trying to recognize scenario 3 where no ACK is received. What confuses me is that my recvfrom() is within a while loop, so the recvfrom() will be called constantly. What will it return when the receiver is not actually sending the sender ACK? Is it 0 or 1?

    Read the article

  • Issuing Current Time Increments in StreamInsight (A Practical Example)

    The issuing of a Current Time Increment, Cti, in StreamInsight is very definitely one of the most important concepts to learn if you want your Streams to be responsive. A full discussion of how to issue Ctis is beyond the scope of this article but a very good explanation in addition to Books Online can be found in these three articles by a member of the StreamInsight team at Microsoft, Ciprian Gerea. Time in StreamInsight Series http://blogs.msdn.com/b/streaminsight/archive/2010/07/23/time-in-streaminsight-i.aspx http://blogs.msdn.com/b/streaminsight/archive/2010/07/30/time-in-streaminsight-ii.aspx http://blogs.msdn.com/b/streaminsight/archive/2010/08/03/time-in-streaminsight-iii.aspx A lot of the problems I see with unresponsive or stuck streams on the MSDN Forums are to do with how Ctis are enqueued or in a lot of cases not enqueued. If you enqueue events and never enqueue a Cti then StreamInsight will be perfectly happy. You, on the other hand, will never see data on the output as you have not told StreamInsight to flush the stream. This article deals with a specific implementation problem I had recently whilst working on a StreamInsight project. I look at some possible options and discuss why they would not work before showing the way I solved the problem. The stream of data I was dealing with on this project was very bursty that is to say when events were flowing they came through very quickly and in large numbers (1000 events/sec), but when the stream calmed down it could be a few seconds between each event. When enqueuing events into the StreamInsight engne it is best practice to do so with a StartTime that is given to you by the system producing the event . StreamInsight processes events and it doesn't matter whether those events are being pushed into the engine by a source system or the events are being read from something like a flat file in a directory somewhere. You can apply the same logic and temporal algebra to both situations. Reading from a file is an excellent example of where the time of the event on the source itself is very important. We could be reading that file a long time after it was written. Being able to read the StartTime from the events allows us to define windows that will hold the correct sets of events. I was able to do this with my stream but this is where my problems started. Below is a very simple script to create a SQL Server table and populate it with sample data that will show exactly the problem I had. CREATE TABLE [dbo].[t] ( [c1] [int] PRIMARY KEY, [c2] [datetime] NULL ) INSERT t VALUES (1,'20100810'),(2,'20100810'),(3,'20100810') Column c2 defines the StartTime of the event on the source and as you can see the values in all 3 rows of data is the same. If we read Ciprian’s articles we know that we can define how Ctis get injected into the stream in 3 different places The Stream Definition The Input Factory The Input Adapter I personally have always been a fan of enqueing Ctis through the factory. Below is code typical of what I would use to do this On the class itself I do some inheriting public class SimpleInputFactory : ITypedInputAdapterFactory<SimpleInputConfig>, ITypedDeclareAdvanceTimeProperties<SimpleInputConfig> And then I implement the following function public AdapterAdvanceTimeSettings DeclareAdvanceTimeProperties<TPayload>(SimpleInputConfig configInfo, EventShape eventShape) { return new AdapterAdvanceTimeSettings( new AdvanceTimeGenerationSettings(configInfo.CtiFrequency, TimeSpan.FromTicks(-1)), AdvanceTimePolicy.Adjust); } The configInfo .CtiFrequency property is a value I pass through to define after how many events I want a Cti to be injected and this in turn will flush through the stream of data. I usually pass a value of 1 for this setting. The second parameter determines the CTI timestamp in terms of a delay relative to the events. -1 ticks in the past results in 1 tick in the future, i.e., ahead of the event. The problem with this method though is that if consecutive events have the same StartTime then only one of those events will be enqueued. In this example I use the following to define how I assign the StartTime of my events currEvent.StartTime = (DateTimeOffset)dt.c2; If I go ahead and run my StreamInsight process with this configuration i can see on the output adapter that two events have been removed To see this in a little more depth I can use the StreamInsight Debugger and see what happens internally. What is happening here is that the first event arrives and a Cti is injected with a time of 1 tick after the StartTime of that event (Also the EndTime of the event). The second event arrives and it has a StartTime of before the Cti and even though we specified AdvanceTimePolicy.Adjust on the factory we know that a point event can never be adjusted like this and the event is dropped. The same happens for the third event as well (The second and third events get trumped by the Cti). For a more detailed discussion of why this happens look here http://www.sqlis.com/sqlis/post/AdvanceTimePolicy-and-Point-Event-Streams-In-StreamInsight.aspx We end up with a single event being pushed into the output adapter and our result now makes sense. The next way I tried to solve this problem by changing the value of the second parameter to TimeSpan.Zero Here is how my factory code now looks public AdapterAdvanceTimeSettings DeclareAdvanceTimeProperties<TPayload>(SimpleInputConfig configInfo, EventShape eventShape) { return new AdapterAdvanceTimeSettings( new AdvanceTimeGenerationSettings(configInfo.CtiFrequency, TimeSpan.Zero), AdvanceTimePolicy.Adjust); } What I am doing here is declaring a policy that says inject a Cti together with every event and stamp it with a StartTime that is equal to the start time of the event itself (TimeSpan.Zero). This method has plus points as well as a downside. The upside is that no events will be lost by having the same StartTime as previous events. The Downside is that because the Cti is declared with the StartTime of the event itself then it does not actually flush that particular event because in the StreamInsight algebra, a Cti commits only those events that occurred strictly before them. To flush the events we need a Cti to be enqueued with a greater StartTime than the events themselves. Here is what happened when I ran this configuration As you can see all we got through was the Cti and none of the events. The debugger output shows the stamps on the Cti and the events themselves. Because the Cti issued has the same timestamp (StartTime) as the events then none of the events get flushed. I was nearly there but not quite. Because my stream was bursty it was possible that the next event would not come along for a few seconds and this was far too long for an event to be enqueued and not be flushed to the output adapter. I needed another solution. Two possible solutions crossed my mind although only one of them made sense when I explored it some more. Where multiple events have the same StartTime I could add 1 tick to the first event, two to the second, three to third etc thereby giving them unique StartTime values. Add a timer to manually inject Ctis The problem with the first implementation is that I would be giving the events a new StartTime. This would cause me the following problems If I want to define windows over the stream then some events may not be captured in the right windows and therefore any calculations on those windows I did would be wrong What would happen if we had 10,000 events with the same StartTime? I would enqueue them with StartTime + n ticks. Along comes a genuine event with a StartTime of the very first event + 1 tick. It is now too far in the past as far as my stream is concerned and it would be dropped. Not what I would want to do at all. I decided then to look at the Timer based solution I created a timer on my input adapter that elapsed every 200ms. private Timer tmr; public SimpleInputAdapter(SimpleInputConfig configInfo) { ctx = new SimpleTimeExtractDataContext(configInfo.ConnectionString); this.configInfo = configInfo; tmr = new Timer(200); tmr.Elapsed += new ElapsedEventHandler(t_Elapsed); tmr.Enabled = true; } void t_Elapsed(object sender, ElapsedEventArgs e) { ts = DateTime.Now - dtCtiIssued; if (ts.TotalMilliseconds >= 200 && TimerIssuedCti == false) { EnqueueCtiEvent(System.DateTime.Now.AddTicks(-100)); TimerIssuedCti = true; } }   In the t_Elapsed event handler I find out the difference in time between now and when the last event was processed (dtCtiIssued). I then check to see if that is greater than or equal to 200ms and if the last issuing of a Cti was done by the timer or by a genuine event (TimerIssuedCti). If I didn’t do this check then I would enqueue a Cti every time the timer elapsed which is not something I wanted. If the difference between the two times is greater than or equal to 500ms and the last event enqueued was by a real event then I issue a Cti through the timer to flush the event Queue, otherwise I do nothing. When I enqueue the Ctis into my stream in my ProduceEvents method I also set the values of dtCtiIssued and TimerIssuedCti   currEvent = CreateInsertEvent(); currEvent.StartTime = (DateTimeOffset)dt.c2; TimerIssuedCti = false; dtCtiIssued = currEvent.StartTime; If I go ahead and run this configuration I see the following in my output. As we can see the first Cti gets enqueued as before but then another is enqueued by the timer and because this has a later timestamp it flushes the enqueued events through the engine. Conclusion Hopefully this has shown how the enqueuing of Ctis can have a dramatic effect on the responsiveness of your output in StreamInsight. Understanding the temporal nature of the product is for me one of the most important things you can learn. I have attached my solution for the demos. It is all in one project and testing each variation is a simple matter of commenting and un-commenting the parts in the code we have been dealing with here.

    Read the article

  • Accelerate your SOA with Data Integration - Live Webinar Tuesday!

    - by dain.hansen
    Need to put wind in your SOA sails? Organizations are turning more and more to Real-time data integration to complement their Service Oriented Architecture. The benefit? Lowering costs through consolidating legacy systems, reducing risk of bad data polluting their applications, and shortening the time to deliver new service offerings. Join us on Tuesday April 13th, 11AM PST for our live webinar on the value of combining SOA and Data Integration together. In this webcast you'll learn how to innovate across your applications swiftly and at a lower cost using Oracle Data Integration technologies: Oracle Data Integrator Enterprise Edition, Oracle GoldenGate, and Oracle Data Quality. You'll also hear: Best practices for building re-usable data services that are high performing and scalable across the enterprise How real-time data integration can maximize SOA returns while providing continuous availability for your mission critical applications Architectural approaches to speed service implementation and delivery times, with pre-integrations to CRM, ERP, BI, and other packaged applications Register now for this live webinar!

    Read the article

  • Jump-start Your Mind

    - by João Angelo
    I haven’t written in a while mostly because I’ve spent my time reading what others wrote and today I’m writing purely motivated by what I just finished reading. Mindfire: Big Ideas for Curious Mind by Scott Berkun was such a pleasure to read and ended up igniting parts of my mind which I have to admit were becoming a bit numb that I felt the urge to take some time to first say thank you to the author and then recommend it to all your curious minds out there. Now, go read it… it’s time well spent.

    Read the article

  • How much does it cost to develop an Android application?

    - by raychenon
    Following the same iPhone question. How much can a development team charge for an Android app like the official Twitter Inc ? In general how much amount of time is devoted to build the likes of Google Goggles , Google Skymap, Gmail with server side applications included :) Now if you're a solo developer and proud to show your app. How much time have you spent so far ? What was your background GUI desktop in Java, C#, web developer, started from zero programming experience ? Disclaimer : I've developed Android apps ( 10 000 downloads) on my free time and one commercial to be published. Just to know the amount of efforts needed to catch up :)

    Read the article

  • Becoming an expert vs boredom [closed]

    - by QAH
    I am a college student, and I love to program, period. I code all kinds of things in different kinds of languages. Although I enjoy programming, I have an extremely hard time sticking to one project for a long time. I attribute this shortcoming to my high level of curiosity, exploring different technologies, languages, libraries, etc. What would be best? Should I settle down more and spend time on becoming an expert in one or two programming fields, or should I be more of a jack of all trades, trying out all kinds of new technologies, languages, programming methods, etc.? I'm guessing that somewhere in the middle would be best. I'm always amazed at how many developers are able to create one or two projects, and develop on them for years. What techniques do you guys employ to help you stay focused on a project?

    Read the article

  • how do you spend your day? a day from a programmer's life [closed]

    - by RBA
    First of all I'm 26 and I'm asking this question because I want to see how do you manage your time. Also I'm interested how do the programmers with a family(wife, several kids) manage their time. I'm asking this due the fact that I'm working aprox 7,5 hours at work (9 to 5), spent 1,5 hours on the way to/from workplace, and when I'm home I must cook/clean/etc and LEARN! And I have the impression that I don't have enough time to learn. Did you have a period similar in your life? To want to learn another language/improve your development/other skills? I saw here and on SO that there are a lot of peoples with +10k points, this in my mind means that they stay on blogs/forums more than 15 hours a day. If you consider this question is a good question, please vote to reopen it. best regards, Radu

    Read the article

  • Newly configured MSSQL2008, TIME_WAIT but no ESTABLISHED?

    - by 3molo
    Windows 2008 R2, standard. No firewall locally on it. Newly setup because an old SQL2000 had two disks die (or could it be the raid controller?) at the same time. Luckily, I had fresh backups. The databases have been restored, and SP2 for SQL2008 applied. I can see various hosts trying to establish a session, but the (customer) sites does not work and I don't see the expected established sessions. A wireshark reveals a full three-way handshake. Since it's customer machines connecting, I cannot logon to them and restart application pools.. What on earth could be causing this? No. Time Source Destination Protocol Info 1 0.000000 1.2.5.127 1.2.6.133 TCP desktop-dna > ms-sql-s [SYN] Seq=0 Win=65535 Len=0 MSS=1380 SACK_PERM=1 Frame 1: 62 bytes on wire (496 bits), 62 bytes captured (496 bits) Ethernet II, Src: Cisco_31:5e:09 (00:26:0b:31:5e:09), Dst: Vmware_b7:00:05 (00:50:56:b7:00:05) Internet Protocol, Src: 1.2.5.127 (1.2.5.127), Dst: 1.2.6.133 (1.2.6.133) Transmission Control Protocol, Src Port: desktop-dna (2763), Dst Port: ms-sql-s (1433), Seq: 0, Len: 0 No. Time Source Destination Protocol Info 2 0.000123 1.2.6.133 1.2.5.127 TCP ms-sql-s > desktop-dna [SYN, ACK] Seq=0 Ack=1 Win=8192 Len=0 MSS=1460 SACK_PERM=1 Frame 2: 62 bytes on wire (496 bits), 62 bytes captured (496 bits) Ethernet II, Src: Vmware_b7:00:05 (00:50:56:b7:00:05), Dst: Cisco_31:5e:09 (00:26:0b:31:5e:09) Internet Protocol, Src: 1.2.6.133 (1.2.6.133), Dst: 1.2.5.127 (1.2.5.127) Transmission Control Protocol, Src Port: ms-sql-s (1433), Dst Port: desktop-dna (2763), Seq: 0, Ack: 1, Len: 0 No. Time Source Destination Protocol Info 3 0.000884 1.2.5.127 1.2.6.133 TCP desktop-dna > ms-sql-s [ACK] Seq=1 Ack=1 Win=65535 Len=0 And netstat TCP 1.2.6.133:1433 1.2.2.98:26895 TIME_WAIT 0 TCP 1.2.6.133:1433 1.2.2.98:26912 TIME_WAIT 0 TCP 1.2.6.133:1433 1.2.2.98:26918 TIME_WAIT 0 TCP 1.2.6.133:1433 1.2.2.98:26931 TIME_WAIT 0 TCP 1.2.6.133:1433 1.2.5.127:2736 TIME_WAIT 0 TCP 1.2.6.133:1433 1.2.5.127:2737 TIME_WAIT 0 TCP 1.2.6.133:1433 1.2.5.127:2738 TIME_WAIT 0 TCP 1.2.6.133:1433 1.2.5.127:2739 TIME_WAIT 0

    Read the article

  • Insert text depending on time of day and day of week.

    - by ploughansen
    I'm trying to piece together a php script to output different text depending on what day it is and the time of day. Example: On weekdays (mon-fri), I would like to output text according to the following periods of time (24H, server time, UTC): 00:00-08:00: "Lorem ipsum" 08:00-13:00: "dolor sit amet" 13:00-15:00: "Pellentesque habitant" 15:00-15:30: "dolor sit amet" 15:30-24:00: "Lorem ipsum" On weekends (sat-sun), I would like to output the following text in this time period: 00:00-24:00 "Lorem ipsum" Can anyone help with a php script to do that? I've already gotten some help over at the css-tricks forum. They supplied this code: <?php $date = strtotime("now"); $hour = date("H", $date); switch($hour) { case 00: case 01: case 02: case 03: case 04: case 05: case 06: case 07: case 08: $dets = array("img" => "image1.png", "txt" => "Lorem ipsum"); break; case 09: case 10: case 11: case 12: case 13: $dets = array("img" => "image2.png", "txt" => "dolor sit amet"); break; case 14: case 15: case 16: $dets = array("img" => "image3.png", "txt" => "Pellentesque habitant"); break; case 17: case 18: case 19: case 20: case 21: case 22: case 23: case 24: $dets = array("img" => "image1.png", "txt" => "Lorem ipsum"); break; } echo "<img src='$dets[img]' alt='$dets[txt]' />"; ?> But it works for all days, and only in full hours. I want to be able to specify per half-hour and on a day to day basis. Still a php-noob so I'm hoping someone can help me.

    Read the article

  • ModalPopup CodeBehind Function Wait For User Response

    - by Snave
    I have set up a function which returns an enum of the button that the user clicked in the ModalPopup. I have a variable of type enum to store which button the user clicks in the button click event. In this function, I call the ModalPopupExtender's Show() method. My problem is, the function finishes out and returns the default enum (which is "none" since no button was clicked yet) before the ModalPopup can be shown and store which button the user clicks. So without changing the function to a method and using a different way to store the user's button click, how can I pause the function after the Show() method of the MPE has been called and wait for the user to click a button? Edit(11/20/2009): Clarification: On the aspx page, I include a ScriptManager, PlaceHolder, and an asp:Button with a codebehind click event. What I want is to click the button, then in the click event handler, I want to call a custom static class function that returns a variable. One of the arguments it takes is the PlaceHolder. The function creates all the necessary controls in the PlaceHolder needed to display a ModalPopup. It calls the created ModalPopupExtender's Show() method. What should happen: At this point is the ModalPopup gets displayed, the user clicks a button, that button's event handler fires, the button sets a variable indicating that it was clicked, it then calls the ModalPopupExtender's .Hide() method, and then the function returns the variable that indicates which button was clicked. We then return to the event handler from the original button that was clicked and the programmer can then perform some logic based on what variable was returned. Crux: When the ModalPopupExtender's .Show() method gets called, it does not display the ModalPopup until AFTER the function returns a default variable (because no button was clicked yet) and after the event handler from the original button that was clicked ends. What I need: After the ModalPopupExtender's .Show() method is called, I need the ModalPopup to get displayed immediately and I need the function to wait for a button click to be made from the ModalPopup. My thoughts: Some PostBack needs to be made to the page telling it to update and display the ModalPopup Panel. Then maybe a while loop can be run in the function that waits for a button to be clicked in the ModalPopup.

    Read the article

  • Run bat file in Java and wait 2

    - by Savvas Dalkitsis
    This is a followup question to my other question : http://stackoverflow.com/questions/2434125/run-bat-file-in-java-and-wait The reason i am posting this as a separate question is that the one i already asked was answered correctly. From some research i did my problem is unique to my case so i decided to create a new question. Please go read that question before continuing with this one as they are closely related. Running the proposed code blocks the program at the waitFor invocation. After some research i found that the waitFor method blocks if your process has output that needs to be proccessed so you should first empty the output stream and the error stream. I did those things but my method still blocks. I then found a suggestion to simply loop while waiting the exitValue method to return the exit value of the process and handle the exception thrown if it is not, pausing for a brief moment as well so as not to consume all the CPU. I did this: import java.io.BufferedReader; import java.io.IOException; import java.io.InputStreamReader; public class Test { public static void main(String[] args) { try { Process p = Runtime.getRuntime().exec( "cmd /k start SQLScriptsToRun.bat" + " -UuserName -Ppassword" + " projectName"); final BufferedReader input = new BufferedReader(new InputStreamReader(p.getInputStream())); final BufferedReader error = new BufferedReader(new InputStreamReader(p.getErrorStream())); new Thread(new Runnable() { @Override public void run() { try { while (input.readLine()!=null) {} } catch (IOException e) { e.printStackTrace(); } } }).start(); new Thread(new Runnable() { @Override public void run() { try { while (error.readLine()!=null) {} } catch (IOException e) { e.printStackTrace(); } } }).start(); int i = 0; boolean finished = false; while (!finished) { try { i = p.exitValue(); finished = true; } catch (IllegalThreadStateException e) { e.printStackTrace(); try { Thread.sleep(500); } catch (InterruptedException e1) { e1.printStackTrace(); } } } System.out.println(i); } catch (IOException e) { e.printStackTrace(); } } } but my process will not end! I keep getting this error: java.lang.IllegalThreadStateException: process has not exited Any ideas as to why my process will not exit? Or do you have any libraries to suggest that handle executing batch files properly and wait until the execution is finished?

    Read the article

  • Buildr, Gradle or wait for Maven 3?

    - by Sten Roger
    I am really tired of struggling with Maven 2 all the time. Build tools should not be in the way. Recently I have been looking at Buildr and Gradle. Maven 3 seems to fix some of the struggles. So, what should I go for now? Buildr? Gradle? Or wait a year for Maven 3?

    Read the article

  • Insert wait in VS2008 web test.

    - by SonOfOmer
    Hi everyone, How can I insert time wait value in web test in Visual Studio 2008 test edition? I have recorded a web test that I want to use in Load test. Now I need to put some time delay between pages in web test. Thanks a lot.

    Read the article

  • wait after presentModalViewController

    - by Cesar
    I need to wait (don't execute the code) after the presentModalViewController until the modal view it's dismissed, it's possible or it's a conceptual error ? -(NSDictionary *)authRequired { [self presentModalViewController:loginRegView animated:YES]; //This view write the settings when dismissed. NSMutableDictionary *ret=[[NSMutableDictionary alloc] init]; [ret setObject:[app.settings get:@"user"] forKey:@"user"]; [ret setObject:[app.settings get:@"pass"] forKey:@"pass"]; return ret; }

    Read the article

  • Javascript Wait and pause

    - by Ajith
    I need to execute a function in javascript named demo() and sample() optionally.ie,first my program will wait for 5 seconds to execute demo(); if it is fail to start demo with in 5 seconds i need to execute sample() automatically (from javascript).is it possible to do in javascript?Please help me....Thanks

    Read the article

  • Wait function in Java

    - by user220755
    So I am writing a Java code to represent a heap sort and to represent the operation I need to have a waiting function which will wait between different operation but I am not sure if there is a function in Java that does that or do I need to write the function by myself and how would i do that. Representing heap sport is a homework but writing the waiting function isn't so I appreciate your help

    Read the article

  • how to put a thread in Wait in Android

    - by Brijesh Masrani
    I have a thread running in my program When Mouse-down Event generates I want to put that thread in wait() and in Mouse-up I want to Notify that thread But when I tried to do this It is giving me error like "Object not locked by Thread" so can anyone help me how to solve this..

    Read the article

  • Wait during iPhone UI modification

    - by paul simmons
    Hi, I am making modifications to elements on UI. There is no (extra) thread or any async. calls. However I want to give a slow motion effect, so wait specific time at each step in a for loop. How can I achieve this without blocking the UI?

    Read the article

  • Please wait screen in asp.net

    - by Zerotoinfinite
    Hi All, The home page of my website and some other page also are taking some time to load, instead of making them load fast, I want some please wait screen or progress bar and mean while the required page would be loaded behind. Is there any way to do it? Thanks in advance

    Read the article

< Previous Page | 29 30 31 32 33 34 35 36 37 38 39 40  | Next Page >