Search Results

Search found 5436 results on 218 pages for 'transfer rate'.

Page 33/218 | < Previous Page | 29 30 31 32 33 34 35 36 37 38 39 40  | Next Page >

  • C# .Net Serial DataReceived Event response too slow for high-rate data.

    - by Matthew
    Hi, I have set up a SerialDataReceivedEventHandler, with a forms based program in VS2008 express. My serial port is set up as follows: 115200, 8N1 Dtr and Rts enabled ReceivedBytesThreshold = 1 I have a device I am interfacing with over a BlueTooth, USB to Serial. Hyper terminal receives the data just fine at any data rate. The data is sent regularly in 22 byte long packets. This device has an adjustable rate at which data is sent. At low data rates, 10-20Hz, the code below works great, no problems. However, when I increase the data rate past 25Hz, there starts to recieve mulitple packets on one call. What I mean by this is that there should be a event trigger for every incoming packet. With higher output rates, I have tested the buffer size (BytesToRead command) immediatly when the event is called and there are multiple packets in the buffer then. I think that the event fires slowly and by the time it reaches the code, more packes have hit the buffer. One test I do is see how many time the event is trigger per second. At 10Hz, I get 10 event triggers, awesome. At 100Hz, I get something like 40 event triggers, not good. My goal for data rate is 100HZ is acceptable, 200Hz preferred, and 300Hz optimum. This should work because even at 300Hz, that is only 52800bps, less than half of the set 115200 baud rate. Anything I am over looking? public Form1() { InitializeComponent(); serialPort1.DataReceived += new SerialDataReceivedEventHandler(serialPort1_DataReceived); } private void serialPort1_DataReceived(object sender, SerialDataReceivedEventArgs e) { this.Invoke(new EventHandler(Display_Results)); } private void Display_Results(object s, EventArgs e) { serialPort1.Read(IMU, 0, serial_Port1.BytesToRead); }

    Read the article

  • How do you set rate limit access to your API using Iptables?

    - by Cory
    How can you set rate limit access to API using Iptables. Tried to set limit using port 80, but I don't want to set limit to the web access entirely. Is there a way to specified a subdomain rather than port. Example: set rate limit to api.example.com not example.com? If there is no way to set rate limit by subdomain, what is the suggested rate limit access to port 80 without risking blocking a legitimate web user? One connection per second would be enough?

    Read the article

  • how to keep display tick rate steady when using continuous collision detection?

    - by nas Ns
    (I've just found about this forum). I hope it is ok to repost my question again here. I posted this question at stackoverflow, but it looks like I might get better help here. Here is the question: I've implemented basic particles motion simulation with continuous collision detection. But there is small issue in display. Assume simple case of circles moving inside square. All elastic collisions. no firction. All motion is constant speed. No forces are involved, no gravity. So when a particle is moving, it is always moving at constant speed (in between collisions) What I do now is this: Let the simulation time step be 1 second (for example). This is the time step simulation is advanced before displaying the new state (unless there is a collision sooner than this). At start of each time step, time for the next collision between any particles or a particle with a wall is determined. Call this the TOC time; let’s say TOC was .5 seconds in this case. Since TOC is smaller than the standard time step, then the system is moved by TOC and the new system is displayed so that the new display shows any collisions as just taking place (say 2 circles just touched each other’s, or a circle just touched a wall) Next, the collision(s) are resolved (i.e. speeds updated, changed directions etc..). A new step is started. The same thing happens. Now assume there is no collision detected within the next 1 second (those 2 circles above will not be in collision any more, even though they are still touching, due to their speeds showing they are moving apart now), Hence, simulation time is advanced now by the full one second, the standard time step, and particles are moved on the screen using 1 second simulation time and new display is shown. You see what has just happened: One frame ran for .5 seconds, but the next frame runs for 1 second, may be the 3rd frame is displayed after 2 seconds, may be the 4th frame is displayed after 2.8 seconds (because TOC was .8 seconds then) and so on. What happens is that the motion of a particle on the screen appears to speed up or slow down, even though it is moving at constant speed and was not even involved in a collision. i.e. Looking at one particle on its own, I see it suddenly speeding up or slowing down, becuase another particle had hit a wall. This is because the display tick is not uniform. i.e. the frame rate update is changing, giving the false illusion that a particle is moving at non-constant speed while in fact it is moving at constant speed. The motion on the screen is not smooth, since the screen is not updating at constant rate. I am not able to figure how to fix this. If I want to show 2 particles at the moment of the collision, I must draw the screen at different times. Drawing the screen always at the same tick interval, results in seeing 2 particles before the collision, and then after the collision, and not just when they colliding, which looked bad when I tried it. So, how do real games handle this issue? How to display things in order to show collisions when it happen, yet keep the display tick constant? These 2 requirements seem to contradict each other’s.

    Read the article

  • Why would I be getting IXFR and AXFR transfer denied on my DNS server?

    - by danielj
    From everything I've researched and tried, it appears that my named.conf is configured correctly, including the allow-transfer section. Here is a sample of the errors. It is only happening with a couple of my secondary servers, but it is happening for every zone for those servers that are failing. One of the servers is attempting IXFR, the other AXFR. The result is the same: 18-Mar-2011 14:27:51.372 security: error: client 84.234.24.90#59208: zone transfer 'juansgaranton.com/IXFR/IN' denied 18-Mar-2011 14:32:18.015 security: error: client 174.37.196.55#50783: zone transfer 'cheshirecat.net/AXFR/IN' denied Here is the relevant part of named.conf. options { directory "/etc/bind"; pid-file "/var/run/named/named.pid"; files 4096; allow-transfer { 140.186.190.103; 84.234.24.90; 207.246.95.34; 203.20.52.5; 140.186.190.103; 127.0.0.1; 174.37.196.55; }; }; logging { channel "bind" { file "/var/log/bind.log" versions 3; print-time yes; print-severity yes; print-category yes; severity info; }; category lame-servers { null; }; category "default" { "bind"; }; };

    Read the article

  • Where do vendors publish internal transfer rates of HDDs?

    - by red888
    So I've started to dig into storage fundamentals and found that in order to calculate the IOPS of a HDD you need to know the internal transfer rate of the drive (time it takes data to move from the platters to internal disk's cache). I went on newegg and even a few vendor sites and could not find this info published for any HDDs. Is it sometimes called something else? Take this link to a seagate HDD for instance. Nowhere do I see "internal transfer rate", but I do see something called "Sustained Data Rate OD"- is that the same thing? Just so you know where I'm getting this info (Book: "Information Storage and Management Storing, Managing..."): Consider an example with the following specifications provided for a disk: The average seek time is 5 ms in a random I/O environment; therefore, T = 5 ms. Disk rotation speed of 15,000 revolutions per minute or 250 revolutions per second — from which rotational latency (L) can be determined, which is one-half of the time taken for a full rotation or L = (0.5/250 rps expressed in ms). 40 MB/s internal data transfer rate, from which the internal transfer time (X) is derived based on the block size of the I/O — for example, an I/O with a block size of 32 KB; therefore X = 32 KB/40 MB. Consequently, the time taken by the I/O controller to serve an I/O of block size 32 KB is (TS) = 5 ms + (0.5/250) + 32 KB/40 MB = 7.8 ms. Therefore, the maximum number of I/Os serviced per second or IOPS is (1/TS) = 1/(7.8 × 10^-3) = 128 IOPS.

    Read the article

  • Trying to get the associated value from an Enum at runtime in Java

    - by devoured elysium
    I want to accomplish something like the following (my interest is in the toInt() method). Is there any native way to accomplish this? If not, how can I get the integer associated with an enum value (like in C#) ? enum Rate { VeryBad(1), Bad(2), Average(3), Good(4), Excellent(5); private int rate; private Rate(int rate) { this.rate = rate; } public int toInt() { return rate; } } Thanks

    Read the article

  • "Google a raté le coche avec Chrome OS" affirment certains experts qui s'inquiètent des retards pris par le système d'exploitation

    "Google a raté le coche avec Chrome OS", affirment certains experts qui s'inquiètent des retards pris par système d'exploitation de Google Chrome OS aurait du voir le jour en 2010. Et pourtant, personne encore ne l'a vu pointer le bout de son nez. Du coup, certains experts s'inquiètent. Pour eux, le marché change vite, trop vite. Chrome OS est destiné a équiper les appareils de puissance moindre, comme les netbooks et les ordinateurs lowcost. Seulement : "il y a un an, personne n'aurait pu prédire les grands changements qui sont survenus". Ce que les analystes veulent dire, c'est qu'au moment où Google à annoncé son produit, les netbooks avaient le vent en poupe. Aujourd'hui, ils so...

    Read the article

  • Why is programming sometimes viewed as a second-rate role?

    - by CaptainCodeman
    I've been a programmer for most of my life. I recently interviewed for a management job in a company and the interviewer looked at my CV asked me "How do we know you're not just a programmer". Which in my opinion is quite a rude thing to say, but it's not an isolated incident and I've heard other similar things in other settings. It does seem that for some reason being a programmer is viewed as having a lower station, especially in settings where they have a separate IT department which is viewed as a support role. Is a career in software development doomed to being a second-rate support citizen?

    Read the article

  • Google a-t-il raté son entrée sur le marché des tablettes ? Android connaît une "croissance pénible" d'après DisplaySearch

    Google a-t-il raté son entrée sur le marché des tablettes ? Android connaît une "croissance pénible" d'après DisplaySearch Six mois après le lancement d'Android 3 (alias Honeycomb), force est de constater que les ventes des tablettes qui tournent dessus sont loin de défrayer les chroniques, elles ne semblent pas être en mesure en tout cas de freiner les ventes frénétiques de l'iPad d'Apple. Pour l'analyste Richard Shim de DisplaySearch, l'univers Android connaît une « croissance pénible » avec Honeycomb : « il est clair que les premières tablettes fondées sur Android ne s'écoulent pas aussi bien que ce que beaucoup attendaient, quelques marques avec lesquelles ...

    Read the article

  • Which one of the Google Analytics stats should be my top priority to improve SEO: visits, pageviews, bounce rate, new visitors, or visit duration

    - by HOY
    My site is getting a lot of traffic from an image (a company logo image) because this image is ranked 1st in Google search results for a company's title. (I have no idea how that happened.) This image is must for my website, but it is not relevant to the site content, so irrelevant people search for the image and find out about my site. I get interesting statistics: Pros: Total Visits & Avg. New Visits Cons: Avg. Page/Visit, Avg. Visit Duration, Bounce Rate I am confused if this image is helpful to my website. I don't know what the balance between those 5 statistics should be. My website is 2 months old, and we are working on SEO at the moment. Edit: here are the details about the image: Search Keyword: arcelik logo Search Site: google.com.tr Search URL

    Read the article

  • Netcat UDP File Transfer Between Two Servers Times Out?

    - by Mark Bowytz
    I'm testing file transfer speeds between two Red Hat servers that are connected to the same switch within the data center and I decided to use netcat to eliminate protocol overhead as much as possible. Testing in TCP mode went well and I was wondering how UDP might fare. On my receiving (client) end, I ran this: nc -u -l 11225 -v > myfile.out And then on the sending (server) end I ran the following: cat myfile.out | nc -u myserver.foo.zzz.com 11225 -v The file I'm testing with is 38 GB but the transfer seems to stop at around 15 GB (one time at 14.9, another at 15.6). I've tested by adding a "-w 5000" just in case it's timing out but no joy. Adding the -v doesn't show anything except acknowledging that the connection occurred. No errors. So - any suggestions as to why would the transfer cease?

    Read the article

  • How to transfer emails from Win XP to Vista or Windows 7?

    - by Suma
    I was using Windows XP computer for a long time, and Outlook Express as my email client. I have lots and lots of email I would like to keep and therefore I want to transfer them to my new computer with Windows 7. I have transferred all my settings using Transfer Files and Settings Wizard, however in Win 7 there is a new mail client called Windows Mail, and I cannot see any option in it to import the Outlook Express mails. How can I transfer my emails from WinXP computer to a Vista or Win7 OS?

    Read the article

  • Is there any chance that my data will get silently corrupted with a robocopy SMB network transfer?

    - by Archagon
    I'm setting up a NAS box for the first time. At the moment, I have most of my data backed up to a few local hard drives, and I intend to transfer all the data to my NAS over ethernet once the RAID array is setup. Since this is all happening over the network, I'm a bit worried about my data getting corrupted silently during transfer. From what I understand, data generally doesn't get corrupted without notice on local transfers because a checksum is performed at some point by the drive or the OS. (This could be totally wrong.) Does the same thing happen with SMB, or is it up to the transferrer to check the integrity of their data? And if it doesn't happen with SMB, is there a protocol that does ensure data integrity? I know that rsync can checksum a transfer, but I'm on Windows and I already have a robocopy configuration that I like. Will my data be safe or do I have to use an external checksum tool to make sure?

    Read the article

  • VLOOKUP in Excel, part 2: Using VLOOKUP without a database

    - by Mark Virtue
    In a recent article, we introduced the Excel function called VLOOKUP and explained how it could be used to retrieve information from a database into a cell in a local worksheet.  In that article we mentioned that there were two uses for VLOOKUP, and only one of them dealt with querying databases.  In this article, the second and final in the VLOOKUP series, we examine this other, lesser known use for the VLOOKUP function. If you haven’t already done so, please read the first VLOOKUP article – this article will assume that many of the concepts explained in that article are already known to the reader. When working with databases, VLOOKUP is passed a “unique identifier” that serves to identify which data record we wish to find in the database (e.g. a product code or customer ID).  This unique identifier must exist in the database, otherwise VLOOKUP returns us an error.  In this article, we will examine a way of using VLOOKUP where the identifier doesn’t need to exist in the database at all.  It’s almost as if VLOOKUP can adopt a “near enough is good enough” approach to returning the data we’re looking for.  In certain circumstances, this is exactly what we need. We will illustrate this article with a real-world example – that of calculating the commissions that are generated on a set of sales figures.  We will start with a very simple scenario, and then progressively make it more complex, until the only rational solution to the problem is to use VLOOKUP.  The initial scenario in our fictitious company works like this:  If a salesperson creates more than $30,000 worth of sales in a given year, the commission they earn on those sales is 30%.  Otherwise their commission is only 20%.  So far this is a pretty simple worksheet: To use this worksheet, the salesperson enters their sales figures in cell B1, and the formula in cell B2 calculates the correct commission rate they are entitled to receive, which is used in cell B3 to calculate the total commission that the salesperson is owed (which is a simple multiplication of B1 and B2). The cell B2 contains the only interesting part of this worksheet – the formula for deciding which commission rate to use: the one below the threshold of $30,000, or the one above the threshold.  This formula makes use of the Excel function called IF.  For those readers that are not familiar with IF, it works like this: IF(condition,value if true,value if false) Where the condition is an expression that evaluates to either true or false.  In the example above, the condition is the expression B1<B5, which can be read as “Is B1 less than B5?”, or, put another way, “Are the total sales less than the threshold”.  If the answer to this question is “yes” (true), then we use the value if true parameter of the function, namely B6 in this case – the commission rate if the sales total was below the threshold.  If the answer to the question is “no” (false), then we use the value if false parameter of the function, namely B7 in this case – the commission rate if the sales total was above the threshold. As you can see, using a sales total of $20,000 gives us a commission rate of 20% in cell B2.  If we enter a value of $40,000, we get a different commission rate: So our spreadsheet is working. Let’s make it more complex.  Let’s introduce a second threshold:  If the salesperson earns more than $40,000, then their commission rate increases to 40%: Easy enough to understand in the real world, but in cell B2 our formula is getting more complex.  If you look closely at the formula, you’ll see that the third parameter of the original IF function (the value if false) is now an entire IF function in its own right.  This is called a nested function (a function within a function).  It’s perfectly valid in Excel (it even works!), but it’s harder to read and understand. We’re not going to go into the nuts and bolts of how and why this works, nor will we examine the nuances of nested functions.  This is a tutorial on VLOOKUP, not on Excel in general. Anyway, it gets worse!  What about when we decide that if they earn more than $50,000 then they’re entitled to 50% commission, and if they earn more than $60,000 then they’re entitled to 60% commission? Now the formula in cell B2, while correct, has become virtually unreadable.  No-one should have to write formulae where the functions are nested four levels deep!  Surely there must be a simpler way? There certainly is.  VLOOKUP to the rescue! Let’s redesign the worksheet a bit.  We’ll keep all the same figures, but organize it in a new way, a more tabular way: Take a moment and verify for yourself that the new Rate Table works exactly the same as the series of thresholds above. Conceptually, what we’re about to do is use VLOOKUP to look up the salesperson’s sales total (from B1) in the rate table and return to us the corresponding commission rate.  Note that the salesperson may have indeed created sales that are not one of the five values in the rate table ($0, $30,000, $40,000, $50,000 or $60,000).  They may have created sales of $34,988.  It’s important to note that $34,988 does not appear in the rate table.  Let’s see if VLOOKUP can solve our problem anyway… We select cell B2 (the location we want to put our formula), and then insert the VLOOKUP function from the Formulas tab: The Function Arguments box for VLOOKUP appears.  We fill in the arguments (parameters) one by one, starting with the Lookup_value, which is, in this case, the sales total from cell B1.  We place the cursor in the Lookup_value field and then click once on cell B1: Next we need to specify to VLOOKUP what table to lookup this data in.  In this example, it’s the rate table, of course.  We place the cursor in the Table_array field, and then highlight the entire rate table – excluding the headings: Next we must specify which column in the table contains the information we want our formula to return to us.  In this case we want the commission rate, which is found in the second column in the table, so we therefore enter a 2 into the Col_index_num field: Finally we enter a value in the Range_lookup field. Important:  It is the use of this field that differentiates the two ways of using VLOOKUP.  To use VLOOKUP with a database, this final parameter, Range_lookup, must always be set to FALSE, but with this other use of VLOOKUP, we must either leave it blank or enter a value of TRUE.  When using VLOOKUP, it is vital that you make the correct choice for this final parameter. To be explicit, we will enter a value of true in the Range_lookup field.  It would also be fine to leave it blank, as this is the default value: We have completed all the parameters.  We now click the OK button, and Excel builds our VLOOKUP formula for us: If we experiment with a few different sales total amounts, we can satisfy ourselves that the formula is working. Conclusion In the “database” version of VLOOKUP, where the Range_lookup parameter is FALSE, the value passed in the first parameter (Lookup_value) must be present in the database.  In other words, we’re looking for an exact match. But in this other use of VLOOKUP, we are not necessarily looking for an exact match.  In this case, “near enough is good enough”.  But what do we mean by “near enough”?  Let’s use an example:  When searching for a commission rate on a sales total of $34,988, our VLOOKUP formula will return us a value of 30%, which is the correct answer.  Why did it choose the row in the table containing 30% ?  What, in fact, does “near enough” mean in this case?  Let’s be precise: When Range_lookup is set to TRUE (or omitted), VLOOKUP will look in column 1 and match the highest value that is not greater than the Lookup_value parameter. It’s also important to note that for this system to work, the table must be sorted in ascending order on column 1! If you would like to practice with VLOOKUP, the sample file illustrated in this article can be downloaded from here. Similar Articles Productive Geek Tips Using VLOOKUP in ExcelImport Microsoft Access Data Into ExcelImport an Access Database into ExcelCopy a Group of Cells in Excel 2007 to the Clipboard as an ImageShare Access Data with Excel in Office 2010 TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Quickly Schedule Meetings With NeedtoMeet Share Flickr Photos On Facebook Automatically Are You Blocked On Gtalk? Find out Discover Latest Android Apps On AppBrain The Ultimate Guide For YouTube Lovers Will it Blend? iPad Edition

    Read the article

  • USB Hub and Ubuntu

    - by aserwin
    I have a powered 7 port hub connected to my Ubuntu box and it does nothing. The devices (zip drive and web cam) work direct, but aren't recognized through the hub. This worked fine in Windows 7. I can't prove it is the OS because this is a new motherboard and processor. Any advice? EDIT : Output from lsusb -v Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x1d6b Linux Foundation idProduct 0x0002 2.0 root hub bcdDevice 3.02 iManufacturer 3 Linux 3.2.0-32-generic ehci_hcd iProduct 2 EHCI Host Controller iSerial 1 0000:00:12.2 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0004 1x 4 bytes bInterval 12 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 5 wHubCharacteristic 0x000a No power switching (usb 1.0) Per-port overcurrent protection bPwrOn2PwrGood 10 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0503 highspeed power enable connect Port 3: 0000.0100 power Port 4: 0000.0100 power Port 5: 0000.0100 power Device Status: 0x0001 Self Powered Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x1d6b Linux Foundation idProduct 0x0002 2.0 root hub bcdDevice 3.02 iManufacturer 3 Linux 3.2.0-32-generic ehci_hcd iProduct 2 EHCI Host Controller iSerial 1 0000:00:13.2 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0004 1x 4 bytes bInterval 12 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 5 wHubCharacteristic 0x000a No power switching (usb 1.0) Per-port overcurrent protection bPwrOn2PwrGood 10 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Port 3: 0000.0100 power Port 4: 0000.0100 power Port 5: 0000.0100 power Device Status: 0x0001 Self Powered Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x1d6b Linux Foundation idProduct 0x0002 2.0 root hub bcdDevice 3.02 iManufacturer 3 Linux 3.2.0-32-generic ehci_hcd iProduct 2 EHCI Host Controller iSerial 1 0000:00:16.2 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0004 1x 4 bytes bInterval 12 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 4 wHubCharacteristic 0x000a No power switching (usb 1.0) Per-port overcurrent protection bPwrOn2PwrGood 10 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Port 3: 0000.0100 power Port 4: 0000.0100 power Device Status: 0x0001 Self Powered Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x1d6b Linux Foundation idProduct 0x0001 1.1 root hub bcdDevice 3.02 iManufacturer 3 Linux 3.2.0-32-generic ohci_hcd iProduct 2 OHCI Host Controller iSerial 1 0000:00:12.0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0002 1x 2 bytes bInterval 255 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 5 wHubCharacteristic 0x0002 No power switching (usb 1.0) Ganged overcurrent protection bPwrOn2PwrGood 2 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Port 3: 0000.0100 power Port 4: 0000.0100 power Port 5: 0000.0100 power Device Status: 0x0001 Self Powered Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x1d6b Linux Foundation idProduct 0x0001 1.1 root hub bcdDevice 3.02 iManufacturer 3 Linux 3.2.0-32-generic ohci_hcd iProduct 2 OHCI Host Controller iSerial 1 0000:00:13.0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0002 1x 2 bytes bInterval 255 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 5 wHubCharacteristic 0x0002 No power switching (usb 1.0) Ganged overcurrent protection bPwrOn2PwrGood 2 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Port 3: 0000.0100 power Port 4: 0000.0100 power Port 5: 0000.0100 power Device Status: 0x0001 Self Powered Bus 006 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x1d6b Linux Foundation idProduct 0x0001 1.1 root hub bcdDevice 3.02 iManufacturer 3 Linux 3.2.0-32-generic ohci_hcd iProduct 2 OHCI Host Controller iSerial 1 0000:00:14.5 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0002 1x 2 bytes bInterval 255 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 2 wHubCharacteristic 0x0002 No power switching (usb 1.0) Ganged overcurrent protection bPwrOn2PwrGood 2 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Device Status: 0x0001 Self Powered Bus 007 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x1d6b Linux Foundation idProduct 0x0001 1.1 root hub bcdDevice 3.02 iManufacturer 3 Linux 3.2.0-32-generic ohci_hcd iProduct 2 OHCI Host Controller iSerial 1 0000:00:16.0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0002 1x 2 bytes bInterval 255 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 4 wHubCharacteristic 0x0002 No power switching (usb 1.0) Ganged overcurrent protection bPwrOn2PwrGood 2 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0303 lowspeed power enable connect Port 2: 0000.0100 power Port 3: 0000.0100 power Port 4: 0000.0100 power Device Status: 0x0001 Self Powered Bus 008 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 1 Single TT bMaxPacketSize0 64 idVendor 0x1d6b Linux Foundation idProduct 0x0002 2.0 root hub bcdDevice 3.02 iManufacturer 3 Linux 3.2.0-32-generic xhci_hcd iProduct 2 xHCI Host Controller iSerial 1 0000:02:00.0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0004 1x 4 bytes bInterval 12 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 2 wHubCharacteristic 0x0009 Per-port power switching Per-port overcurrent protection TT think time 8 FS bits bPwrOn2PwrGood 10 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Device Status: 0x0001 Self Powered Bus 009 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 3.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 3 bMaxPacketSize0 9 idVendor 0x1d6b Linux Foundation idProduct 0x0003 3.0 root hub bcdDevice 3.02 iManufacturer 3 Linux 3.2.0-32-generic xhci_hcd iProduct 2 xHCI Host Controller iSerial 1 0000:02:00.0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 31 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0004 1x 4 bytes bInterval 12 bMaxBurst 0 Hub Descriptor: bLength 12 bDescriptorType 42 nNbrPorts 2 wHubCharacteristic 0x0009 Per-port power switching Per-port overcurrent protection bPwrOn2PwrGood 10 * 2 milli seconds bHubContrCurrent 0 milli Ampere bHubDecLat 0.0 micro seconds wHubDelay 0 nano seconds DeviceRemovable 0x00 Hub Port Status: Port 1: 0000.02a0 5Gbps power Rx.Detect Port 2: 0000.02a0 5Gbps power Rx.Detect Binary Object Store Descriptor: bLength 5 bDescriptorType 15 wTotalLength 15 bNumDeviceCaps 1 SuperSpeed USB Device Capability: bLength 10 bDescriptorType 16 bDevCapabilityType 3 bmAttributes 0x00 Latency Tolerance Messages (LTM) Supported wSpeedsSupported 0x0008 Device can operate at SuperSpeed (5Gbps) bFunctionalitySupport 3 Lowest fully-functional device speed is SuperSpeed (5Gbps) bU1DevExitLat 3 micro seconds bU2DevExitLat 2047 micro seconds Device Status: 0x0001 Self Powered Bus 001 Device 002: ID 04a9:1709 Canon, Inc. PIXMA MP150 Scanner Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x04a9 Canon, Inc. idProduct 0x1709 PIXMA MP150 Scanner bcdDevice 1.08 iManufacturer 1 Canon iProduct 2 MP150 iSerial 3 20BC24 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 62 bNumInterfaces 2 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xc0 Self Powered MaxPower 2mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 3 bInterfaceClass 255 Vendor Specific Class bInterfaceSubClass 0 bInterfaceProtocol 255 iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x07 EP 7 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x88 EP 8 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x89 EP 9 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0040 1x 64 bytes bInterval 11 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 1 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 7 Printer bInterfaceSubClass 1 Printer bInterfaceProtocol 2 Bidirectional iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x01 EP 1 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x82 EP 2 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered Bus 007 Device 002: ID 046d:c517 Logitech, Inc. LX710 Cordless Desktop Laser Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 8 idVendor 0x046d Logitech, Inc. idProduct 0xc517 LX710 Cordless Desktop Laser bcdDevice 38.10 iManufacturer 1 Logitech iProduct 2 USB Receiver iSerial 0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 59 bNumInterfaces 2 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xa0 (Bus Powered) Remote Wakeup MaxPower 98mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 3 Human Interface Device bInterfaceSubClass 1 Boot Interface Subclass bInterfaceProtocol 1 Keyboard iInterface 0 HID Device Descriptor: bLength 9 bDescriptorType 33 bcdHID 1.10 bCountryCode 0 Not supported bNumDescriptors 1 bDescriptorType 34 Report wDescriptorLength 59 Report Descriptors: ** UNAVAILABLE ** Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0008 1x 8 bytes bInterval 10 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 1 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 3 Human Interface Device bInterfaceSubClass 1 Boot Interface Subclass bInterfaceProtocol 2 Mouse iInterface 0 HID Device Descriptor: bLength 9 bDescriptorType 33 bcdHID 1.10 bCountryCode 0 Not supported bNumDescriptors 1 bDescriptorType 34 Report wDescriptorLength 177 Report Descriptors: ** UNAVAILABLE ** Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x82 EP 2 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0008 1x 8 bytes bInterval 10 Device Status: 0x0000 (Bus Powered) This is with the powered hub plugged in.

    Read the article

  • How can I transfer photo's from my Kodak camera that normally would use KODAK EASYSHARE Software?

    - by Ryan
    Normally I would plug my camera into my Windows XP pc, and the software would auto start, and transfer the files to a set location. I need to be able to perform the same or similar function on my PC installed with Ubuntu 10.04 (LTS). I would like to plug the camera in (USB), and then be able to select the files I want. At the moment, the camera does not seem to recognise the PC. I do not want to rely on the Windows PC anymore.

    Read the article

  • How to download apps from different OS to USB and then transfer to Ubuntu?

    - by kb67
    I just installed Ubuntu on my old desktop computer, and I have to say—I freaking love it! Except at the moment I do not have internet connection (i'm using a unsecured connection) and i'm using my Windows 7 Laptop to get a connection to the web. I would love to install some useful apps on the desktop, but I can't figure out how to do this, is there any way to download Ubuntu/Linux apps on my windows computer and put them into a USB then transfer to the desktop?

    Read the article

  • Allow a web designer to modify DNS without letting them transfer the domain?

    - by PhilCK
    We are in the process of having a web designer create a new website for us, but I don't want to give access to the control panel for the domain names (and have no way to limit it, it seems), while at the same time I don't want to be the go between guy for editing the settings. Is there a way or a service for me to point the domains at a 3rd party DNS system, that I can then give access for the web designer, without worrying that he can find my personal info or try and transfer my domain out?

    Read the article

  • cordova 2.0.0 download file Android

    - by N0rA
    I tried to use cordova 2.0.0 API FileTransfer().download() and i got 2 consecutive errors 1) download error source file 2) download error target file here is my code... function downloadMaterial() { var fileTransfer = new FileTransfer(); var serverURL = 'http://img.youm7.com/images/NewsPics/large/S2200921125437.jpg'; var uri = encodeURI(serverURL); var filePath = persistent_root.fullPath+"/" + fileName; //filePath = file:///data/data/com.example.studyapp/S2200921125437.jpg var onSuccess = function (entry) { console.log("download complete: " + entry.fullPath); }; var onError = function (error) { console.log("download error source " + error.source); console.log("download error target " + error.target); console.log("upload error code " + error.code); }; fileTransfer.download(uri, filePath , onSuccess, onError); } Do you have any idea what should I do? Thanks in advance ...

    Read the article

  • DTO or Domain Model Object in the View Layer?

    - by smayers81
    I know this is probably an age-old question, but what is the better practice? Using a domain model object throughout all layers of your application, and even binding values directly to them on the JSP (I'm using JSF). Or convert a domain model object into a DTO in the DAO or Service layer and send a lightweight DTO to the presentation layer. I have been told it makes no sense to use DTOs because changes to the database will result in changes to all your DTOs whereas using Model Objects everywhere will just require changes to the affected model object. However, the ease of use and the lightweight nature of DTOs seems to outweigh that. I should note that my app uses Hibernate Model Objects AND uses its own custom-created model objects (meaning not bound to any DB session, always detached). Is either of the above scenarios more beneficial to a strict Model Object pattern? Using Hibernate has been a huge PITA with regards to things like Lazy Initialization Exceptions.

    Read the article

  • Getting error while transfering PGP file through FTP : The underlying connection was closed: An unex

    - by sumeet Sharma
    I am trying to upload a PGP encrypted file through FTP. But I am getting an error message as follows: The underlying connection was closed: An unexpected error occurred on a receive. I am using the following code and getting the error at line: Stream ftpStream = response.GetResponse(); Is there any one who can help me out ASAP. Following is the code sample: FtpWebRequest request = WebRequest.Create("ftp://ftp.website.com/sample.txt.pgp") as FtpWebRequest; request.UsePassive = true; FtpWebResponse response = request.GetResponse() as FtpWebResponse; Stream ftpStream = response.GetResponse(); int bufferSize = 8192; byte[] buffer = new byte[bufferSize]; using (FileStream fileStream = new FileStream("localfile.zip", FileMode.Create, FileAccess.Write)) { int nBytes; while((nBytes = ftpStream.Read(buffer, 0, bufferSize) > 0) { fileStream.Write(buffer, 0, nBytes); } } Regards, Sumeet

    Read the article

  • What's a good way to copy files from a PC to a Windows Mobile device?

    - by MusiGenesis
    I have a C# application running on a server, and it needs to copy files out to multiple Windows Mobile 5.0 devices. These devices are connected to the network directly via Ethernet-enabled cradles (so they are not connected to a PC via ActiveSync). What different options do I have for doing this? I know RAPI can do this, but I'm not sure if it can copy something directly over the network like this. Also, I know RAPI uses ActiveSync DLLs and thus requires ActiveSync to be installed, and we would prefer to avoid doing this if possible. Is WMI a possibility? Can we use ordinary File.IO if we can somehow get the IP address of each device? Code samples or general knowledge would be most welcome.

    Read the article

  • Business Objects - Containers or functional?

    - by Walter
    Where I work, we've gone back and forth on this subject a number of times and are looking for a sanity check. Here's the question: Should Business Objects be data containers (more like DTOs) or should they also contain logic that can perform some functionality on that object. Example - Take a customer object, it probably contains some common properties (Name, Id, etc), should that customer object also include functions (Save, Calc, etc.)? One line of reasoning says separate the object from the functionality (single responsibility principal) and put the functionality in a Business Logic layer or object. The other line of reasoning says, no, if I have a customer object I just want to call Customer.Save and be done with it. Why do I need to know about how to save a customer if I'm consuming the object? Our last two projects have had the objects separated from the functionality, but the debate has been raised again on a new project. Which makes more sense? EDIT These results are very similar to our debates. One vote to one side or another completely changes the direction. Does anyone else want to add their 2 cents? EDIT Eventhough the answer sampling is small, it appears that the majority believe that functionality in a business object is acceptable as long as it is simple but persistence is best placed in a separate class/layer. We'll give this a try. Thanks for everyone's input...

    Read the article

< Previous Page | 29 30 31 32 33 34 35 36 37 38 39 40  | Next Page >