Search Results

Search found 1148 results on 46 pages for 'capacity'.

Page 34/46 | < Previous Page | 30 31 32 33 34 35 36 37 38 39 40 41  | Next Page >

  • Apache, Tomcat 5 and problem with HTTP basic auth

    - by Juha Syrjälä
    I have setup a Tomcat with a webapp that uses http basic auth in some of its URLs. There is a Apache server in front of the Tomcat. I have setup Apache as a proxy like this (all traffic should go directly to tomcat): /etc/httpd/conf.d/proxy_ajp.conf: LoadModule proxy_ajp_module modules/mod_proxy_ajp.so ProxyPass / ajp://localhost:8009/ ProxyPassReverse / ajp://localhost:8009/ There is a webapp installed to root of Tomcat (ROOT.war), so I should be able to use http://localhost/ to access my webapp. But it is not working with http basic auth. The problem is that everything works until I try to access URL that are protected by the HTTP basic auth. URLs without authentication work just fine. When accessing this url via apache I am getting an error message from Apache. If I access the same URL directly from tomcat, everything works just fine. I am getting this to Apache error log: [Wed Sep 01 21:34:01 2010] [error] proxy: dialog to [::1]:8009 (localhost) failed access log looks like this: ::1 - - [01/Sep/2010:21:34:01 +0300] "GET /protected_path/ HTTP/1.0" 503 360 "-" "w3m/0.5.2" I am using: Fedora release 13 (Goddard) httpd-2.2.16-1.fc13.x86_64 tomcat5-5.5.27-7.4.fc12.noarch The basic auth is implemented in the webapp (not in Apache or Tomcat). The webapp is actually implemented in Scala/Lift, but that shouldn't matter. The auth works if I access the tomcat directly. Error message that I am getting from Apache. It is curious that the title is Unauthorized and not Internal error: Unauthorized The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later. Apache/2.2.16 (Fedora) Server at my.server.name.com Port 80 It could be that Apache is seeing a some thing else than 200 OK response and thinks that it is an error when it actually should pass the received 401 Unauthorized response directly to browser. If this is the problem, how to fix it?

    Read the article

  • Issues with creating USB bootable Mountain Lion

    - by Sidd
    I am trying to set up a triple boot Windows 8, Mountain Lion, and Ubuntu. I am stuck though. I have got Windows 8 on a partition, and I am trying to get Mountain Lion on there at this point. I installed a VMware with a Snow Leopard 10.6.2 image on the Windows 8 platform. I used the disk utility in this program in order to get Mountain Lion on there. This is what i did specifically: I got the installesd.dmg. I 'mounted' that file or whatever you call it, and out came something along the lines of "Install Mountain Lion OS x" (something like that - it was like a submenu under the installesd.dmg in the disk utility). I got my PNY 8 gb Attache Flash Drive and went to the Erase tab of disk utility. I erased it using the Mac OS Extended (Journaled) setting and called it "Mac". I went to the Restore tab, dragged "Mac" into destination, and dragged "Install Mountain Lion OS x" to the source. Everything seemed to go well, but it didn't. When trying to boot from the flash drive (and yes, I set the BIOS correctly), it skipped it, and loaded Windows 8 normally as if nothing was plugged in. When I try looking at the flash drive in windows 8, it comes up as a 200 mb capacity drive labeled "EFI" with nothing in it (remember, it was 8gb in the beginning). I downloaded Plop Boot Manager, but it did not recognize a USB being plugged in. Does anyone know how I could fix this?

    Read the article

  • ZFS: Mirror vs. RAID-Z

    - by John Clayton
    I'm planning on building a file server using OpenSolaris and ZFS that will provide two primary services - be an iSCSI target for XenServer virtual machines & be a general home file server. The hardware I'm looking at includes 2x 4-port SATA controllers, 2x small boot drives (one on each controller), and 4x big drives for storage. This allows one free port per controller for upgrading the array down the road. Where I'm a little confused is how to setup the storage drives. For performance, mirroring appears to be king. I'm having a hard time seeing what the benefit would be of using RAIDZ over mirroring would be. With this setup I can see two options - two mirrored pools in one stripe, or RAIDZ2. Both should protect against 2 drive failures, and/or one controller failure...the only benefit of RAIDZ2 would be that any 2 drives could fail. The storage should be 50% of capacity in both cases, but the first should have much better performance, right? The other thing I'm trying to wrap my mind around is the benefit of mirrored arrays with more than two devices. For data integrity what, if any, would be the benefit of a RAIDZ over a three-way mirror? Since ZFS maintains file integrity what does RAIDZ bring to the table...doesn't ZFS's integrity checks negate the value of RAIDZ's parity?

    Read the article

  • How to remove request blocking on apache reverse proxy after failure of backend before asking backen

    - by matnagel
    I am working on an apache2 reverse proxy vhost. When the server behind apache is down, the first request to apache shows the error page of course. But at subsequent requests it seems apache delays for some time before asking the backend server again. During all this time (which is short but in development I don't want a delay at all) only the apache error page is shown to the browser, although the backend server is already up. Where is this setting in apache, what is this behaviour, and how can I set the delay time to zero? Edit: I am not trying to change the timeout for a single request. I want to change the blocking time. It is my experience that apache blocks further requests for a certain time before asking a backend server again that has failed once. Edit2: This is what apache delivers: Service Temporarily Unavailable The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later. Apache/2.2.8 (Ubuntu) PHP/5.2.4-2ubuntu5.7 with Suhosin-Patch proxy_html/3.0.0 Server at localhost Port 80 After hitting Ctrl-R in firefox for 60 seconds the page finally appears.

    Read the article

  • Mirror a RAID0 volume

    - by Ghostrider
    I have two SSD running in RAID0. The capacity and speed are just great. I use Windows Home Server to do incremental daily backups. This is fine and well and I've successfully restored from these backups. However. When one of the disks physically died. I was stuck without a working system until the replacement arrives so that I can restore the array from backup. WHS restoration takes about 5 hours which basically means that I'm losing entire day for the process. Is it possible to set up kind of a recovery volume for the RAID array? Use a single mechanical HDD that would be updated with the exact clone of the RAID array on a daily basis. This way if the array goes offline for some reason, I can just boot from the mechanical HDD, lose some perf but will still be able to work. The machine in question runs Windows 7. Creating RAID01 is not an option because of the high price of the SSD and the fact that it still doesn't protect against failure of RAID controller. Is there any way it can be set up?

    Read the article

  • Limiting interface bandwidth with tc under Linux

    - by Matt
    I have a linux router which has a 10GBe interface on the outside and bonded Gigabit ethernet interfaces on the inside. We have currently budget for 2GBit/s. If we exceed that rate by more than 5% average for a month then we'll be charged for the whole 10Gbit/s capacity. Quite a step up in dollar terms. So, I want to limit this to 2GBit/s on 10GBe interface. TBF filter might be ideal, but this comment is of concern. On all platforms except for Alpha, it is able to shape up to 1mbit/s of normal traffic with ideal minimal burstiness, sending out data exactly at the configured rates. Should I be using TBF or some other filter to apply this rate to the interface and how would I do it. I don't understand the example given here: Traffic Control HOWTO In particular "Example 9. Creating a 256kbit/s TBF" tc qdisc add dev eth0 handle 1:0 root dsmark indices 1 default_index 0 tc qdisc add dev eth0 handle 2:0 parent 1:0 tbf burst 20480 limit 20480 mtu 1514 rate 32000bps How is the 256K bit/s rate calculated? In this example, 32000bps = 32k bytes per second. Since tc uses bps = bytes per second. I guess burst and limit come into play but how would you go about choosing sensible numbers to reach the desired rate? This is not a mistake. I tested this and it gave a rate close to 256K but not exactly that.

    Read the article

  • 0 connected nodes in datastax opscenter

    - by gansbrest
    Installed opscenterd on the separate node outside of the cluster, but within firewall ( aws security group ). Tested all possible ports between agents and opcenter server. No errors in the log.. 2013-10-30 01:07:23+0000 [FC_Cluster] INFO: Initializing event storage. 2013-10-30 01:07:23+0000 [FC_Cluster] INFO: Attempting to load all persisted alert rules 2013-10-30 01:07:23+0000 [FC_Cluster] INFO: Done loading persisted alert rules 2013-10-30 01:07:23+0000 [FC_Cluster] INFO: Done initializing event storage. 2013-10-30 01:07:23+0000 [FC_Cluster] INFO: Done loading persisted scheduled job descriptions 2013-10-30 01:07:23+0000 [FC_Cluster] INFO: OpsCenter starting up. 2013-10-30 01:07:23+0000 [] INFO: Finished starting new cluster services for FC_Cluster 2013-10-30 01:08:04+0000 [FC_Cluster] INFO: Agent for ip 10.34.10.185 is version u'3.2.2' 2013-10-30 01:08:04+0000 [FC_Cluster] INFO: Agent for ip 10.32.37.251 is version u'3.2.2' 2013-10-30 01:08:04+0000 [FC_Cluster] INFO: Agent for ip 10.82.226.252 is version u'3.2.2' The most interesting part that I can see some data in the opscenter UI, when I stop agents, there is no data displayed, when I start - it show up again, but at the same time it shows 0 connected nodes. Storage capacity is even funnier - 3 of 0 nodes.. Any ideas why that could be happening?

    Read the article

  • Mac Mail sent messages not in sent folder

    - by Elizabeth Akers
    Hi. My powerbook G4 has been lobbying for a furlough recently, and its latest prank is to not show sent messages in my sent mailbox. I have always had a copy of every sent message, and now, for some unknown reason, I can only see sent messages from May 7 and earlier. When I did a test, and sent myself an email, it shows up fine in my inbox, but there's nothing in the sent folder. Weird. It also has the little arrow next to messages that I replied to in the inbox. I guess I'm going to have to cc myself on everything until I get this fixed. Also, it's got another new trick, which I'm assuming is unrelated, but I mention it here just in case it is: the battery says it's "good" and has a cycle count of 0, and a full charge capacity of 2139, but for some reason it's all of a sudden not charging when it's plugged in. It works fine when connected to the wall, but there is no battery life at all. Zip. Any thoughts? Is it just time for a new 'book? This one just got back from Apple, having its harddrive replaced for the fourth time (for free, but seriously, this thing is a lemon). Thanks so much, Elizabeth

    Read the article

  • Cannot Install Bootcamp on Mac Fusion Drive

    - by user3377019
    I have two drive installed in my mid-2013 Macbook pro. It is running osx maverick. I set the two drives (an ssd and a regular HD) up using the fusion drive (following the diy fusion drive guides out there). I went ahead and created a 40gb partition to host my windows install. I removed the SSD, installed windows, then reinstalled the SSD. As soon as the ssd was placed back in the bootcamp partition stopped booting. I get a blinking cursor on a black screen. I checked out the partition info in disk utility and it appears that the windows partition is not marked bootable. Below is some info I managed to gather. I am wondering if there is a way to fix the partition table so my bootcamp will boot. /dev/disk0 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *120.0 GB disk0 1: EFI EFI 209.7 MB disk0s1 2: Apple_CoreStorage 119.7 GB disk0s2 3: Apple_Boot Boot OS X 134.2 MB disk0s3 /dev/disk1 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *500.1 GB disk1 1: EFI EFI 209.7 MB disk1s1 2: Microsoft Basic Data BOOTCAMP 40.0 GB disk1s2 3: Apple_CoreStorage 459.2 GB disk1s3 4: Apple_Boot Boot OS X 650.0 MB disk1s4 /dev/disk2 #: TYPE NAME SIZE IDENTIFIER 0: Apple_HFS Macintosh HD *573.4 GB disk2 Name : BOOTCAMP Type : Partition Disk Identifier : disk1s2 Mount Point : /Volumes/BOOTCAMP File System : Windows NT File System (NTFS) Connection Bus : SATA Device Tree : IODeviceTree:/PCI0@0/SATA@1F,2/PRT1@1/PMP@0 Writable : No Universal Unique Identifier : 584BAED6-4C46-4F18-93B3-957F6E27003C Capacity : 40 GB (39,998,980,096 Bytes) Free Space : 16.34 GB (16,339,972,096 Bytes) Used : 23.66 GB (23,659,003,904 Bytes) Number of Files : 86,424 Number of Folders : 0 Owners Enabled : No Can Turn Owners Off : No Can Be Formatted : No Bootable : No Supports Journaling : No Journaled : No Disk Number : 1 Partition Number : 2

    Read the article

  • iBook G4 has black screen on boot

    - by Jonathan Patt
    I have an old iBook G4 (A1054, 1.2 GHz) which has issues when it loses power or is shut off. If the battery drains—which happens quickly, as its remaining capacity is very low—it enters some sort of weird mode where it's not really awake (the screen is black, can't do anything) but it has no pulsing light indicating it's asleep either. The only way to exit this mode is to hold down the power button for ten seconds until it shuts off, and attempt rebooting it. Almost always, however, it makes the sound of the optical drive starting up, and then doesn't continue past that point. The screen doesn't come on, and things like resetting PRAM don't work. Occasionally a fan comes on loudly for a second or two. This sometimes seems to correspond with my pressing down on the rear-right casing, above the power jack. In the past, shutting it off, disconnecting it from power, removing the battery and waiting for 30 minutes would do the trick, but this time I have done that several times, letting it sit for up to several hours before retrying, to no avail. Any ideas?

    Read the article

  • Is this memory compatible with this motherboard???

    - by ClarkeyBoy
    Hi, I have a Foxconn P35AP-S as seen here. I need to get some more RAM since I only have 1 2GB stick. The current one is 1066MHz. I would like to get the memory situated here: www.scan.co.uk/Products/6GB-(3x2GB)-Corsair-XMS3-Classic-DDR3-PC3-10666-(1333)-Non-ECC-Unbuffered-CAS-7-7-7-20-165V memory. It is 6GB of Corair 1333MHz memory. According to the motherboard website it is able to take 1333MHz, but it says oc** next to it (which means achieved when overclocked). So my question is: are they still compatible without overclocking, or does the motherboard require overclocking to be compatible? If it requires overclocking (which I have no idea how to do) can anyone recommend any other memory (in the region of 6GB) which the motherboard is compatible with? I'd rather it were from Scan, but to be honest it doesnt need to be. Many thanks in advance. Regards, Richard Edit: I just realised that the motherboard has a maximum capacity of 4GB of RAM. Scrap the RAM given above, I'd like to go for something like that but only 4GB. Edit: Scrap that last edit - its only if I go for DDR3 that I need to take this into account. DDR2 is a maximum of 8GB.

    Read the article

  • Pitfalls to using Gluster as a home/profile directory server?

    - by Bart Silverstrim
    I was asking recently about options for divvying up access to file servers, as we have a NAS solution that gets fairly bogged down when our users (with giant profiles, especially) all log in nearly simultaneously. I ran across Gluster and it looks like it can cluster different physical storage media into a single virtual volume and share it out like a virtual NAS from the client perspective and it support CIFS. My question is whether something like this would be feasible to use for home and profile directories in an active directory environment. I was worried about ACL's, primarily, as I didn't think CIFS was fine-grained enough to support NTFS permissions and it didn't look like Gluster exports those permission levels, just the base permissions for basic file sharing. I got the impression that using Gluster would allow for data to be redundant across multiple servers and would speed up access to the files under heavy load, while allowing us to dynamically boost storage capacity by just adding another server and telling Gluster's master node to add that server. Maybe I'm wrong with my understanding of it though. Anyone else use it or care to share how feasible this is?

    Read the article

  • What's up with stat on Macos/Darwin? Or filesystems without names...

    - by Charles Stewart
    In response to a question I asked on SO, Give the mount point of a path, one respondant suggested using stat to get the device name associated with the volume of a given path. This works nicely on Linux, but gives crazy results on Macos 10.4. For my system, df and mount give: cas cas$ df Filesystem 512-blocks Used Avail Capacity Mounted on /dev/disk0s3 58342896 49924456 7906440 86% / devfs 194 194 0 100% /dev fdesc 2 2 0 100% /dev 1024 1024 0 100% /.vol automount -nsl [166] 0 0 0 100% /Network automount -fstab [170] 0 0 0 100% /automount/Servers automount -static [170] 0 0 0 100% /automount/static /dev/disk2s1 163577856 23225520 140352336 14% /Volumes/Snapshot /dev/disk2s2 409404102 5745938 383187960 1% /Volumes/Sparse cas cas$ mount /dev/disk0s3 on / (local, journaled) devfs on /dev (local) fdesc on /dev (union) on /.vol automount -nsl [166] on /Network (automounted) automount -fstab [170] on /automount/Servers (automounted) automount -static [170] on /automount/static (automounted) /dev/disk2s1 on /Volumes/Snapshot (local, nodev, nosuid, journaled) /dev/disk2s2 on /Volumes/Sparse (asynchronous, local, nodev, nosuid) Trying to get the devices from the mount points, though: cas cas$ df | grep -e/ | awk '{print $NF}' | while read line; do echo $line $(stat -f"%Sdr" $line); done / disk0s3r /dev ???r /dev ???r /.vol ???r /Network ???r /automount/Servers ???r /automount/static ???r /Volumes/Snapshot disk2s1r /Volumes/Sparse disk2s2r Here, I'm feeding each of the mount points scraped from df to stat, outputing the results of the "%Sdr" format string, which is supposed to be the device name: Cf. stat(1) man page: The special output specifier S may be used to indicate that the output, if applicable, should be in string format. May be used in combination with: ... dr Display actual device name. What's going on? Is it a bug in stat, or some Darwin VFS weirdness? Postscript Per Andrew McGregor, try passing "%Sd" to stat for more weirdness. It lists some apparently arbitrary subset of files from CWD...

    Read the article

  • What's up with stat on Mac OS X/Darwin? Or filesystems without names...

    - by Charles Stewart
    In response to a question I asked on SO, Give the mount point of a path, one respondant suggested using stat to get the device name associated with the volume of a given path. This works nicely on Linux, but gives crazy results on Mac OS X 10.4. For my system, df and mount give: cas cas$ df Filesystem 512-blocks Used Avail Capacity Mounted on /dev/disk0s3 58342896 49924456 7906440 86% / devfs 194 194 0 100% /dev fdesc 2 2 0 100% /dev <volfs> 1024 1024 0 100% /.vol automount -nsl [166] 0 0 0 100% /Network automount -fstab [170] 0 0 0 100% /automount/Servers automount -static [170] 0 0 0 100% /automount/static /dev/disk2s1 163577856 23225520 140352336 14% /Volumes/Snapshot /dev/disk2s2 409404102 5745938 383187960 1% /Volumes/Sparse cas cas$ mount /dev/disk0s3 on / (local, journaled) devfs on /dev (local) fdesc on /dev (union) <volfs> on /.vol automount -nsl [166] on /Network (automounted) automount -fstab [170] on /automount/Servers (automounted) automount -static [170] on /automount/static (automounted) /dev/disk2s1 on /Volumes/Snapshot (local, nodev, nosuid, journaled) /dev/disk2s2 on /Volumes/Sparse (asynchronous, local, nodev, nosuid) Trying to get the devices from the mount points, though: cas cas$ df | grep -e/ | awk '{print $NF}' | while read line; do echo $line $(stat -f"%Sdr" $line); done / disk0s3r /dev ???r /dev ???r /.vol ???r /Network ???r /automount/Servers ???r /automount/static ???r /Volumes/Snapshot disk2s1r /Volumes/Sparse disk2s2r Here, I'm feeding each of the mount points scraped from df to stat, outputting the results of the "%Sdr" format string, which is supposed to be the device name: Cf. stat(1) man page: The special output specifier S may be used to indicate that the output, if applicable, should be in string format. May be used in combination with: ... dr Display actual device name. What's going on? Is it a bug in stat, or some Darwin VFS weirdness? Postscript Per Andrew McGregor, try passing "%Sd" to stat for more weirdness. It lists some apparently arbitrary subset of files from CWD...

    Read the article

  • LSI MegaRAID LINUX got Optimal after degradation but strange POST message

    - by kesrut
    Linux server box with LSI MegaRAID controller got degraded. But after some time RAID status changed to Optimal. Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 2.727 TB Mirror Data : 2.727 TB State : Optimal Strip Size : 256 KB Number Of Drives per span:2 Span Depth : 3 Default Cache Policy: WriteBack, ReadAdaptive, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Is VD Cached: No But now I'm getting RAID BIOS POST message: Your battery is either charging, bad or missing, and you have VDs configured for write-back mode. Because the battery is not currently usable, these VDs willl actually run in write-through mode until the battery is fully charged or replaced if it is bad or missing. (Image: http://cl.ly/image/1h1O093b1i2d) So may it be battery issue caused problem ? I get information about battery: BatteryType: iBBU Voltage: 4001 mV Current: 0 mA Temperature: 22 C Battery State : Operational BBU Firmware Status: Charging Status : None Voltage : OK Temperature : OK Learn Cycle Requested : No Learn Cycle Active : No Learn Cycle Status : OK Learn Cycle Timeout : No I2c Errors Detected : No Battery Pack Missing : No Battery Replacement required : No Remaining Capacity Low : No Periodic Learn Required : No Transparent Learn : No No space to cache offload : No Pack is about to fail & should be replaced : No Cache Offload premium feature required : No Module microcode update required : No Where can be problem ? I'm disabled alarms, but get them if enabled. But don't know how find root of problem.

    Read the article

  • How to configure SCSI hard drives and RAID for Poweredge 2850 web server

    - by Saul
    I'm trying to set up a Poweredge 2850 as a web server, but as a server novice it's causing me some confusion. Its a virgin install so no data to be lost as yet, so I'd like to get the best arrangement for setting up Windows Server 2008. The box will run IIS, a mail and FTP server. The current physical arrangement of the hot swap drives is 1 73GB 3 146GB 5 blank 0 73GB 2 146GB 4 146GB (but flashes green, amber off) When I enter the PERC config screens on boot up I've got Raid Ch- 0 ID 0 ONLIN A00-00 1 ONLIN A00-01 2 ONLIN A01-00 3 ONLIN A01-01 4 HOTSP I think that drives 0 and 1 are set to RAID 1 and drives 2 and 3 are also set to RAID 1, certainly I can see 2 logical drives, both raid 1 of 69880MB and 139900MB Now what I think I am getting here is that the 2 73GB drives mirror each other and the 2 146GB drives mirror 2? so by my noob thinking if a drive fails I can pull it, insert and new one and it will reduplicate from its matching pair? I think the flashing amber probably indicates a failing drive in slot 4, should that just be binned? What confuses me coming from a home user XP background is that when I load up Windows Server 2008 OS under my computer I only see a C drive of about 70GB capacity. i.e wheres the 146GB drive? Any advice appreciated

    Read the article

  • Page pool memory

    - by legiwei
    I'm currently using Windows XP SP3 32 bit, using C2D E6320 with 2GB RAM. When I am playing Starcraft 2, I encounter an error where it says my system is running low on page pool memory. Starcraft graphic settings suggested a high settings for me. I do not think it has to do with my GC but with my RAM. I then made a search to try to rectify the problem. Apparently, it's something to do with my virtual memory. I then proceed to try to the suggested solution which is to temper the registry and limit the page pool memory to 384MB. However, having done so, I still could not achieved it. I've seen screenshot settings of windows XP with 2GB having 384MB of page pool memory. My default settings puts it at 195MB whereas when I try to increase the pool limit, it can only go to a max of 229MB. I tried increasing my RAM capacity to 3GB but the pool limit still remains. I like to know how to increase my page pool memory. I've tried searching for solution but to no avail other than the one that I've mentioned above (which didn't solve my problem completely).

    Read the article

  • SSD cache to minimize HDD spin-up time?

    - by sirprize
    short version first: I'm looking for Linux compatible software which is able to transparently cache HDD writes using an SSD. However, I only want to spin up the HDD once or twice a day (to write the cached data to the HDD). The rest of the time, the HDD should not be spinning due to noise concerns. Now the longer version: I have built a completely silent computer running Xubuntu. It has a A10-6700T APU, huge fanless cooler, fanless PSU, SSD. The problem is: it also has (and needs) a noisy HDD and I want to forbid spinning it up during the night. All writes should be cached on the SSD, reads are not needed in the night. Throughout every day, this computer will automatically download about 5 GB of data which will be retained for about a year, giving a total needed disk capacity of slightly less than 2 TB. This data is currently stored on a 3 TB noisy hard disk drive which is spinning day and night. Sometimes, I'll need to access some data from several months ago. However, most times I'll only need data from the last 14 days, which would fit on the SSD. Ideally, I'd like a transparent solution (all data on one filesystem) which caches all writes to the SSD, writing to the HDD only once a day. Reads would be served by the cache if they were still on the SDD, else the HDD would have to spin up. I have tried bcache without much success (using cache_mode=writeback, writeback_running=0, writeback_delay=86400, sequential_cutoff=0, congested_write_threshold_us=0 - anything missing?) and I read about ZFS ZIL/L2ARC but I'm not sure I can achieve my goal with ZFS. Any pointers? If all else fails, I will simply use some scripts to automatically copy files over to the big drive while deleting the oldest files from the SSD.

    Read the article

  • VMWare Guest Info - Wrong IP Returned

    - by Jon Bailey
    We're running a VDI environment with vSphere 4.0 and Oracle VDI 3.2.2 and are having a bit of a problem with users that connect to an IPSec VPN from within their VM. For some reason, once connected to the VPN, the VMWare API returns GuestInfo.ipAddress as the VPN IP rather than the primary IP of the only NIC on the system. The IP address shown in net[0].ipAddress is the correct address and is what vSphere client is reporting. Is there any way to get VMWare tools to report the net[0].ipAddress as GuestInfo.ipAddress? Below is sample output from the guestinfo.pl script. 172.16.1.2 is the example "bad" VPN address that our VDI software is seeing. VMXFLEX01 guestFamily: windowsGuest VMXFLEX01 guestFullName: Microsoft Windows XP Professional (32-bit) VMXFLEX01 guestId: winXPProGuest VMXFLEX01 guestState: running VMXFLEX01 hostName: VMXFLEX01 VMXFLEX01 ipAddress: 172.16.1.2 VMXFLEX01 toolsStatus: VMware Tools is running and the version is current. VMXFLEX01 toolsVersion: 8194 VMXFLEX01 Screen - Height: 600 VMXFLEX01 Screen - Width: 800 VMXFLEX01 Disk[0]: Capacity 42935926784 VMXFLEX01 Disk[0]: Path : C:\ VMXFLEX01 Disk[0]: freespace : 33272619008 VMXFLEX01 net[0] - connected : 1 VMXFLEX01 net[0] - deviceConfigId : 4000 VMXFLEX01 net[0] - macAddress : 00:50:56:95:1f:c9 VMXFLEX01 net[0] - network : VM Network VMXFLEX01 net[0] - ipAddress : 10.0.0.2

    Read the article

  • Recommendations for colocation in the US

    - by Emil
    Hello serverfault I work for a European media company and we are currently looking for colocation in the US. I know the European market quite well unfortunately that is not the case for the US. I'm hoping for you guys to help me out a bit with a few questions, it would be much appreciated! I am looking for a data center that can deliver a high level of availability (tier 3 or better). The installation will be fairly large so capacity is important. Good internet connectivity/carrier presence. However most important is good customer support, skilled dedicated and responsive technical staff, since we won't have tech staff close by. I'm looking for a small and fast moving company that target internet businesses rather than big old enterprise hosting. What locations should we go for given that we want to reach all of the US from a single site and still maintain decent latency? (do we need east and west coast?) Where are the main internet hubs and should you try and get as close as possible? Are there any good online resources I should look at? Where do the large scale internet/media services colocate? Lastly I would be very happy to get some actual recommendations for companies to talk to P.S I'm happy to return the favor if anyone has question regarding data centers and colocation in Europe.

    Read the article

  • Ubuntu lucid, maverick high iowait

    - by netom
    I'm using Ubuntu, and I've got the same problem with Lucid and Maverick. From time to time, especially a few minutes after boot, the iowait goes between 50-100% and the box is unusable. Everything that tries to access the disk freezes. I have the following setup: Hard disk: Model Family: Western Digital Caviar Green family Device Model: WDC WD15EADS-00P8B0 Serial Number: WD-WMAVU0391287 Firmware Version: 01.00A01 User Capacity: 1.500.301.910.016 bytes I have a quad core Intel Core2 Q6600 processor, and 4G of memory. When the high iowait occurs, usually 4 processes are active: kdmflush (two procs) jbd2/dm-0-8 jbd2/db-1-8 and a few more starving user processes of course. I know this from top and iotop. Any suggestions about why this is happening? There are a lot of q/a-s about linux and high iowait, but none of them helped so far, I even tweaked the hard disk not to park the head in every 8 seconds (Load cycle count is 50334!!!!! :o ), but nothing. Problem persists. Thank you in advance.

    Read the article

  • Is StoreJet Transcend (0x2329) an Advanced Format drive?

    - by Graham Perrin
    I use a 640 GB StoreJet Transcend (0x2329) with ZEVO Community Edition 1.1.1 on OS X 10.8.2. Question Is this drive Advanced Format? Background I submitted a request for technical support to Transcend but the first response was gibberish so I don't expect a reasonable follow-up. Models at http://www.transcend-info.com/Products/CatList.asp?LangNo=0&ModNo=293 are similar but different sizes (not 640 GB). Mine is probably 25M2 (TS640GSJ25M2): Unless I'm missing something, nothing currently in the Transcend support area tells me whether the drive is Advanced Format. From System Information in OS X 10.8.2: StoreJet Transcend: Capacity: 640.14 GB (640,135,028,736 bytes) Removable Media: Yes Detachable Drive: Yes BSD Name: disk3 Product ID: 0x2329 Vendor ID: 0x152d (JMicron Technology Corp.) Version: 0.00 Serial Number: 322549FBA004 Speed: Up to 480 Mb/sec Manufacturer: JMicron History for the ZFS pool shows creation in March 2012 –  macbookpro08-centrim:~ gjp22$ zpool history zhandy | grep create 2012-03-14.17:29:37 zpool create -f -O compression=off -O copies=1 -O casesensitivity=insensitive -O snapdir=visible zhandy /dev/dsk/GPTE_1928482A-7FE4-482D-B692-3EC6B03159BA 2012-06-22.15:51:16 zfs create zhandy/Pocket Time Machine At that time I almost certainly used ZEVO Setup Assistant to create the pool. macbookpro08-centrim:~ gjp22$ zpool get ashift zhandy NAME PROPERTY VALUE SOURCE zhandy ashift 0 default If I discover that the drive is Advanced Format, a different ashift value will be appropriate.

    Read the article

  • Best way to attach 96 tb to workstation

    - by user994179
    I'm running a workstation with dual xeon 5690's (12 physical/24 logical cores), 192 gb of ram (ie, maxed-out), Windows 7 64bit, 5 slots for adapter cards, and 1 tb of internal storage, with 5 more internal bays available. I have an app that creates data files totaling about 88 tbs. These are written once every 14 months, and the rest of the time the app only needs to read them; and 95% of the reads are sequential reads of huge chunks of data. I have some control over how big the individual files are, but ideally they would be between 5 and 8 tbs. The app will be reading from only one drive at a time, and the nature of the data is such that if (when) a drive dies I can restore the data to a new disk from tape. While it would be nice to be able to use the fastest drive/controllers available, at this point size matters more than speed. After doing lots of reading, I am leaning toward buying a bunch of cheap 2tb drives and putting them into a bunch of cheap enclosures. All this stuff is going into my home office, so I need to avoid the raised floor/refrigerated approach. My questions: Is the cheap drive/enclosure solution the best one for this situation? Given the nature of the app and the way the data is used, does RAID make sense? If so, which one? For huge sequential reads, would Usb 3.0 and eSata be a wash performance-wise? For each slot available on the workstation, can I hook up an enclosure that can hold multiple drives? Or is it one controller per drive? If I can have multiple drives on one controller, am I essentially splitting the bandwidth (throughput)? For example, if I have a 12 bay enclosure, is the throughput of the controller reduced by a factor of 12? Are there any Windows 7 volume/drive/capacity limits I should be aware of? Thanks

    Read the article

  • Replacing all disks in a non-OS RAID 5 volume

    - by molecule
    Hi all, We currently have a server with 8 x HDD slots. It is a HP DL380G5 with a P400 controller. 2 x HDD are in a RAID 1+0 config and this hosts the OS. 6 x HDD are in a RAID 5 config and holds an Oracle DB. Basically the RAID 5 volume is running out of space and we would like to swap all 6 with higher capacity disks. Excuse my ignorance as I am pretty new to this... I believe we will need to backup the data, delete the RAID volume, insert the new disks, recreate the volume, and restore the data. 2 questions: Do we need to worry about the OS partition or is it completely independent so we can simply take out the 6 and insert 6 new disks and get the controller to recognize the 6 new disks and form a new RAID 5 volume? We should not need to reinstall OS or Oracle correct? Since we are going to restore the data on the volume from another source (our vendor will take care of this) but we would like to keep the existing data on the 6 disks just in case we run into issues and want to fall back, is this possible? Thanks in advance.

    Read the article

  • Starting my own server - basic recommendations and questions [closed]

    - by Ilia Rostovtsev
    Possible Duplicate: Can you help me with my capacity planning? I'm planning to start my own high-performance server and then use collocation services for keeping it up and running. I'm planning to USE it for processing videos and keeping big video site up! (using FFMpeg, MENcoder and etc.) I just need recommendations on whether listed hardware is good enough and will work together well and fast enough. Do I need anything else (missed something). I remember about CPU coolers though! ;) I'm planning to use SSD drives so please tell me if it's going to work just as regular HDDs (but much faster)? Are they going to be used as RAID (is this possible for SSDs)? Here is what I would like to get: Intel ® Server System SR1600URHSR (Urbanna) or Intel® Server System SR1695WBAC 2 x Intel Xeon X5650 4 x 16Gb DDR-III 1333MHz Kingston ECC Reg (KVR13R9D4/16) 3 x (or maybe 4x) 480Gb SSD Intel 520 Series (SSDSC2CW480A3K5) Which server system would be better? Is listed hardware new/good enough and worth buying it at the moment? Should I probably take a look at something slightly more expensive but more up to date and powerful, may be? After all as software I would like to use CentOS 6 64 bit + WHM/CPanel? Any other suggestions on maybe cheaper and same/more powerful server management system but WHM? What most important points to keep in mind when starting/maintaining your own server?

    Read the article

< Previous Page | 30 31 32 33 34 35 36 37 38 39 40 41  | Next Page >