Search Results

Search found 53463 results on 2139 pages for 'net generics'.

Page 34/2139 | < Previous Page | 30 31 32 33 34 35 36 37 38 39 40 41  | Next Page >

  • Serializing Complex ViewModel with Json.Net Destabilization Error on Latest Version

    - by dreadlocks1221
    I just added the latest Version of JSON.Net and I get the System.Security.VerificationException: Operation could destabilize the runtime error when trying to use a controller (while running the application). I read in other posts that this issue should have been fixed in release 6 but I still have the problem. I even added *Newtonsoft.* to the ignore modules in the intellitrace options, which seems to have suppressed the error, but the post will just run forever and not return anything. Any help I can get would be greatly appreciated. [HttpPost] public string GetComments(int ShowID, int Page) { int PageSize = 10; UserRepository UserRepo = new UserRepository(); ShowCommentViewModel viewModel = new ShowCommentViewModel(); IQueryable<Comment> CommentQuery = showRepository.GetShowComments(ShowID); var paginatedComments = new PaginatedList<Comment>(CommentQuery, Page, PageSize); viewModel.Comments = new List<CommentViewModel>(); foreach (Comment comment in CommentQuery.Take(10).ToList()) { CommentViewModel CommentModel = new CommentViewModel { Comment = comment, PostedBy = UserRepo.GetUserProfile(comment.UserID) }; IQueryable<Comment> ReplyQuery = showRepository.GetShowCommentReplies(comment.CommentID); int ReplyPage = 0; var paginatedReplies = new PaginatedList<Comment>(ReplyQuery, ReplyPage, 3); CommentModel.Replies = new List<ReplyModel>(); foreach (Comment reply in ReplyQuery.Take(3).ToList()) { ReplyModel rModel = new ReplyModel { Reply = reply, PostedBy = UserRepo.GetUserProfile(reply.UserID) }; CommentModel.Replies.Add(rModel); } CommentModel.RepliesNextPage = paginatedReplies.HasNextPage; CommentModel.RepliesPeviousPage = paginatedReplies.HasPreviousPage; CommentModel.RepliesTotalPages = paginatedReplies.TotalPages; CommentModel.RepliesPageIndex = paginatedReplies.PageIndex; CommentModel.RepliesTotalCount = paginatedReplies.TotalCount; viewModel.Comments.Add(CommentModel); } viewModel.CommentsNextPage = paginatedComments.HasNextPage; viewModel.CommentsPeviousPage = paginatedComments.HasPreviousPage; viewModel.CommentsTotalPages = paginatedComments.TotalPages; viewModel.CommentsPageIndex = paginatedComments.PageIndex; viewModel.CommentsTotalCount = paginatedComments.TotalCount; return JsonConvert.SerializeObject(viewModel, Formatting.Indented); }

    Read the article

  • .NET EventHandlers - Generic or no?

    - by Chris Marasti-Georg
    Every time I start in deep in a C# project, I end up with lots of events that really just need to pass a single item. I stick with the EventHandler/EventArgs practice, but what I like to do is have something like: public delegate void EventHandler<T>(object src, EventArgs<T> args); public class EventArgs<T>: EventArgs { private T item; public EventArgs(T item) { this.item = item; } public T Item { get { return item; } } } Later, I can have my public event EventHandler<Foo> FooChanged; public event EventHandler<Bar> BarChanged; However, it seems that the standard for .NET is to create a new delegate and EventArgs subclass for each type of event. Is there something wrong with my generic approach? EDIT: The reason for this post is that I just re-created this in a new project, and wanted to make sure it was ok. Actually, I was re-creating it as I posted. I found that there is a generic EventHandler<TEventArgs, so you don't need to create the generic delegate, but you still need the generic EventArgs<T class, because TEventArgs: EventArgs. Another EDIT: One downside (to me) of the built-in solution is the extra verbosity: public event EventHandler<EventArgs<Foo>> FooChanged; vs. public event EventHandler<Foo> FooChanged; It can be a pain for clients to register for your events though, because the System namespace is imported by default, so they have to manually seek out your namespace, even with a fancy tool like Resharper... Anyone have any ideas pertaining to that?

    Read the article

  • [Asp.Net MVC] Encoding a character

    - by Trimack
    Hi, I am experiencing some weird encoding behaviour in my ASP.NET MVC project. In my Site.Master there is <div class="logo"> <a href="<%=Url.Action("Index", "Win7")%>"><%= Html.Encode("Windows 7 Tutoriál") %></a></div> which translates to the resulting page as <div class="logo"> <a href="/">Windows 7 TutoriA?l</a></div> However, in the Index.aspx there is <h1> Windows 7 Tutoriál</h1> which translates correctly on the same resulting page. I do have <meta http-equiv="Content-Type" content="text/html; charset=utf-8" /> as my first line in <head>. Locally, both files are saved in UTF-8 encoding. Any ideas why is this happening and how to fix it? Thanks in advance.

    Read the article

  • asp.net mvc outputting json with backslashes ( escape) despite many attemps to filter

    - by minus4
    i have an asp.net controller that output Json as the results a section of it is here returnString += string.Format(@"{{""filename"":""{0}"",""line"":[", file.Filename); what i get returned is this: "{\"DPI\":\"66.8213457076566\",\"width\":\"563.341067\",\"editable\":\"True\",\"pricecat\":\"6\",\"numpages\":\"2\",\"height\":\"400\",\"page\":[{\"filename\":\"999_9_1.jpg\",\"line\":[]},{\"filename\":\"999_9_2.jpg\",\"line\":[]}]]" i have tried to return with the following methods: return Json(returnString); return Json(returnString.Replace("\\",""); return Json will serialize my string to a jSon string, this i know but it likes to escape for some reason, how can i get rid of it ???? for info this is how i call it with jQuery: $.ajax({ url:"/Products/LoadArtworkToJSon", type:"POST", dataType: "json", async: false, data:{prodid: prodid }, success: function(data){ sessvars.myData = data; measurements = sessvars.myData; $("#loading").remove(); //empty the canvas and create a new one with correct data, always start on page 0; $("#movements").remove(); $("#canvas").append("<div id=\"movements\" style=\"width:" + measurements.width + "px; height:" + Math.round(measurements.height) + "px; display:block; border:1px solid black; background:url(/Content/products/" + measurements.page[0].filename + ") no-repeat;\"></div>"); your help is much appreciated thanks

    Read the article

  • Implementing a normal website inside ASP.NET MVC 2

    - by cc0
    I have a website consisting of an index.html, a number of style sheet files as well as some javascript files. Then I needed a way for this site to communicate efficiently with a Microsoft SQL Server, so I was recommended to use the MVC framework to facilitate that kind of communication. I created the C#.net controller code needed to output the necessary information from the database using URL parameters, so now I am trying to put the whole web-site together inside the MVC framework. I started an empty project-template in MVC 2 framework. I'm sure there must be a good way to implement the current code into this framework, but I am very uncertain as to what the best approach to this would be. Could anyone point me in the right direction here? I'm not sure whether I need to change any of the current HTML, or exactly what to add to it. I'd love to see some kind of guide or tutorial, or just any advice I can get as I try to learn this. Any help is very much appreciated!

    Read the article

  • .net runtime type casting when using reflection

    - by Mike
    I have need to cast a generic list of a concrete type to a generic list of an interface that the concrete types implement. This interface list is a property on an object and I am assigning the value using reflection. I only know the value at runtime. Below is a simple code example of what I am trying to accomplish: public void EmployeeTest() { IList<Employee> initialStaff = new List<Employee> { new Employee("John Smith"), new Employee("Jane Doe") }; Company testCompany = new Company("Acme Inc"); //testCompany.Staff = initialStaff; PropertyInfo staffProperty = testCompany.GetType().GetProperty("Staff"); staffProperty.SetValue(testCompany, (staffProperty.PropertyType)initialStaff, null); } Classes are defined like so: public class Company { private string _name; public string Name { get { return _name; } set { _name = value; } } private IList<IEmployee> _staff; public IList<IEmployee> Staff { get { return _staff; } set { _staff = value; } } public Company(string name) { _name = name; } } public class Employee : IEmployee { private string _name; public string Name { get { return _name; } set { _name = value; } } public Employee(string name) { _name = name; } } public interface IEmployee { string Name { get; set; } } Any thoughts? I am using .NET 4.0. Would the new covariant or contravariant features help? Thanks in advance.

    Read the article

  • ASP.NET MVC, Url Routing: Maximum Path (URL) Length

    - by Martin Aatmaa
    The Scenario I have an application where we took the good old query string URL structure: ?x=1&y=2&z=3&a=4&b=5&c=6 and changed it into a path structure: /x/1/y/2/z/3/a/4/b/5/c/6 We're using ASP.NET MVC and (naturally) ASP.NET routing. The Problem The problem is that our parameters are dynamic, and there is (theoretically) no limit to the amount of parameters that we need to accommodate for. This is all fine until we got hit by the following train: HTTP Error 400.0 - Bad Request ASP.NET detected invalid characters in the URL. IIS would throw this error when our URL got past a certain length. The Nitty Gritty Here's what we found out: This is not an IIS problem IIS does have a max path length limit, but the above error is not this. Learn dot iis dot net How to Use Request Filtering Section "Filter Based on Request Limits" If the path was too long for IIS, it would throw a 404.14, not a 400.0. Besides, the IIS max path (and query) length are configurable: <requestLimits maxAllowedContentLength="30000000" maxUrl="260" maxQueryString="25" /> This is an ASP.NET Problem After some poking around: IIS Forums Thread: ASP.NET 2.0 maximum URL length? http://forums.iis.net/t/1105360.aspx it turns out that this is an ASP.NET (well, .NET really) problem. The shit of the matter is that, as far as I can tell, ASP.NET cannot handle paths longer than 260 characters. The nail in the coffin in that this is confirmed by Phil the Haack himself: Stack Overflow ASP.NET url MAX_PATH limit Question ID 265251 The Question So what's the question? The question is, how big of a limitation is this? For my app, it's a deal killer. For most apps, it's probably a non-issue. What about disclosure? No where where ASP.NET Routing is mentioned have I ever heard a peep about this limitation. The fact that ASP.NET MVC uses ASP.NET routing makes the impact of this even bigger. What do you think?

    Read the article

  • Subterranean IL: Generics and array covariance

    - by Simon Cooper
    Arrays in .NET are curious beasts. They are the only built-in collection types in the CLR, and SZ-arrays (single dimension, zero-indexed) have their own commands and IL syntax. One of their stranger properties is they have a kind of built-in covariance long before generic variance was added in .NET 4. However, this causes a subtle but important problem with generics. First of all, we need to briefly recap on array covariance. SZ-array covariance To demonstrate, I'll tweak the classes I introduced in my previous posts: public class IncrementableClass { public int Value; public virtual void Increment(int incrementBy) { Value += incrementBy; } } public class IncrementableClassx2 : IncrementableClass { public override void Increment(int incrementBy) { base.Increment(incrementBy); base.Increment(incrementBy); } } In the CLR, SZ-arrays of reference types are implicitly convertible to arrays of the element's supertypes, all the way up to object (note that this does not apply to value types). That is, an instance of IncrementableClassx2[] can be used wherever a IncrementableClass[] or object[] is required. When an SZ-array could be used in this fashion, a run-time type check is performed when you try to insert an object into the array to make sure you're not trying to insert an instance of IncrementableClass into an IncrementableClassx2[]. This check means that the following code will compile fine but will fail at run-time: IncrementableClass[] array = new IncrementableClassx2[1]; array[0] = new IncrementableClass(); // throws ArrayTypeMismatchException These checks are enforced by the various stelem* and ldelem* il instructions in such a way as to ensure you can't insert a IncrementableClass into a IncrementableClassx2[]. For the rest of this post, however, I'm going to concentrate on the ldelema instruction. ldelema This instruction pops the array index (int32) and array reference (O) off the stack, and pushes a pointer (&) to the corresponding array element. However, unlike the ldelem instruction, the instruction's type argument must match the run-time array type exactly. This is because, once you've got a managed pointer, you can use that pointer to both load and store values in that array element using the ldind* and stind* (load/store indirect) instructions. As the same pointer can be used for both input and output to the array, the type argument to ldelema must be invariant. At the time, this was a perfectly reasonable restriction, and maintained array type-safety within managed code. However, along came generics, and with it the constrained callvirt instruction. So, what happens when we combine array covariance and constrained callvirt? .method public static void CallIncrementArrayValue() { // IncrementableClassx2[] arr = new IncrementableClassx2[1] ldc.i4.1 newarr IncrementableClassx2 // arr[0] = new IncrementableClassx2(); dup newobj instance void IncrementableClassx2::.ctor() ldc.i4.0 stelem.ref // IncrementArrayValue<IncrementableClass>(arr, 0) // here, we're treating an IncrementableClassx2[] as IncrementableClass[] dup ldc.i4.0 call void IncrementArrayValue<class IncrementableClass>(!!0[],int32) // ... ret } .method public static void IncrementArrayValue<(IncrementableClass) T>( !!T[] arr, int32 index) { // arr[index].Increment(1) ldarg.0 ldarg.1 ldelema !!T ldc.i4.1 constrained. !!T callvirt instance void IIncrementable::Increment(int32) ret } And the result: Unhandled Exception: System.ArrayTypeMismatchException: Attempted to access an element as a type incompatible with the array. at IncrementArrayValue[T](T[] arr, Int32 index) at CallIncrementArrayValue() Hmm. We're instantiating the generic method as IncrementArrayValue<IncrementableClass>, but passing in an IncrementableClassx2[], hence the ldelema instruction is failing as it's expecting an IncrementableClass[]. On features and feature conflicts What we've got here is a conflict between existing behaviour (ldelema ensuring type safety on covariant arrays) and new behaviour (managed pointers to object references used for every constrained callvirt on generic type instances). And, although this is an edge case, there is no general workaround. The generic method could be hidden behind several layers of assemblies, wrappers and interfaces that make it a requirement to use array covariance when calling the generic method. Furthermore, this will only fail at runtime, whereas compile-time safety is what generics were designed for! The solution is the readonly. prefix instruction. This modifies the ldelema instruction to ignore the exact type check for arrays of reference types, and so it lets us take the address of array elements using a covariant type to the actual run-time type of the array: .method public static void IncrementArrayValue<(IncrementableClass) T>( !!T[] arr, int32 index) { // arr[index].Increment(1) ldarg.0 ldarg.1 readonly. ldelema !!T ldc.i4.1 constrained. !!T callvirt instance void IIncrementable::Increment(int32) ret } But what about type safety? In return for ignoring the type check, the resulting controlled mutability pointer can only be used in the following situations: As the object parameter to ldfld, ldflda, stfld, call and constrained callvirt instructions As the pointer parameter to ldobj or ldind* As the source parameter to cpobj In other words, the only operations allowed are those that read from the pointer; stind* and similar that alter the pointer itself are banned. This ensures that the array element we're pointing to won't be changed to anything untoward, and so type safety within the array is maintained. This is a typical example of the maxim that whenever you add a feature to a program, you have to consider how that feature interacts with every single one of the existing features. Although an edge case, the readonly. prefix instruction ensures that generics and array covariance work together and that compile-time type safety is maintained. Tune in next time for a look at the .ctor generic type constraint, and what it means.

    Read the article

  • Asp.net MVC VirtualPathProvider views parse error

    - by madcapnmckay
    Hi, I am working on a plugin system for Asp.net MVC 2. I have a dll containing controllers and views as embedded resources. I scan the plugin dlls for controller using StructureMap and I then can pull them out and instantiate them when requested. This works fine. I then have a VirtualPathProvider which I adapted from this post public class AssemblyResourceProvider : VirtualPathProvider { protected virtual string WidgetDirectory { get { return "~/bin"; } } private bool IsAppResourcePath(string virtualPath) { var checkPath = VirtualPathUtility.ToAppRelative(virtualPath); return checkPath.StartsWith(WidgetDirectory, StringComparison.InvariantCultureIgnoreCase); } public override bool FileExists(string virtualPath) { return (IsAppResourcePath(virtualPath) || base.FileExists(virtualPath)); } public override VirtualFile GetFile(string virtualPath) { return IsAppResourcePath(virtualPath) ? new AssemblyResourceVirtualFile(virtualPath) : base.GetFile(virtualPath); } public override CacheDependency GetCacheDependency(string virtualPath, IEnumerable virtualPathDependencies, DateTime utcStart) { return IsAppResourcePath(virtualPath) ? null : base.GetCacheDependency(virtualPath, virtualPathDependencies, utcStart); } } internal class AssemblyResourceVirtualFile : VirtualFile { private readonly string path; public AssemblyResourceVirtualFile(string virtualPath) : base(virtualPath) { path = VirtualPathUtility.ToAppRelative(virtualPath); } public override Stream Open() { var parts = path.Split('/'); var resourceName = Path.GetFileName(path); var apath = HttpContext.Current.Server.MapPath(Path.GetDirectoryName(path)); var assembly = Assembly.LoadFile(apath); return assembly != null ? assembly.GetManifestResourceStream(assembly.GetManifestResourceNames().SingleOrDefault(s => string.Compare(s, resourceName, true) == 0)) : null; } } The VPP seems to be working fine also. The view is found and is pulled out into a stream. I then receive a parse error Could not load type 'System.Web.Mvc.ViewUserControl<dynamic>'. which I can't find mentioned in any previous example of pluggable views. Why would my view not compile at this stage? Thanks for any help, Ian EDIT: Getting closer to an answer but not quite clear why things aren't compiling. Based on the comments I checked the versions and everything is in V2, I believe dynamic was brought in at V2 so this is fine. I don't even have V3 installed so it can't be that. I have however got the view to render, if I remove the <dynamic> altogether. So a VPP works but only if the view is not strongly typed or dynamic This makes sense for the strongly typed scenario as the type is in the dynamically loaded dll so the viewengine will not be aware of it, even though the dll is in the bin. Is there a way to load types at app start? Considering having a go with MEF instead of my bespoke Structuremap solution. What do you think?

    Read the article

  • Add new row to asp .net grid view using button

    - by SARAVAN
    Hi, I am working in ASP .net 2.0. I am a learner. I have a grid view which has a button in it. Please find the asp mark up below <form id="form1" runat="server"> <div> <asp:GridView ID="myGridView" runat="server"> <Columns> <asp:TemplateField> <ItemTemplate> <asp:Button CommandName="AddARowBelow" Text="Add A Row Below" runat="server" /> </ItemTemplate> </asp:TemplateField> </Columns> </asp:GridView> </div> </form> Please find the code behind below. using System; using System.Collections.Generic; using System.Linq; using System.Web; using System.Web.UI; using System.Data; using System.Web.UI.WebControls; namespace GridViewDemo { public partial class _Default : System.Web.UI.Page { protected void Page_Load(object sender, EventArgs e) { DataTable dt = new DataTable("myTable"); dt.Columns.Add("col1"); dt.Columns.Add("col2"); dt.Columns.Add("col3"); dt.Rows.Add(1, 2, 3); dt.Rows.Add(1, 2, 3); dt.Rows.Add(1, 2, 3); dt.Rows.Add(1, 2, 3); dt.Rows.Add(1, 2, 3); myGridView.DataSource = dt; myGridView.DataBind(); } protected void myGridView_RowCommand(object sender, GridViewCommandEventArgs e) { } } } I was thinking that when I click the command button, it would fire the mygridview_rowcommand() but instead it threw an error as follows: Invalid postback or callback argument. Event validation is enabled using in configuration or <%@ Page EnableEventValidation="true" % in a page. For security purposes, this feature verifies that arguments to postback or callback events originate from the server control that originally rendered them. If the data is valid and expected, use the ClientScriptManager.RegisterForEventValidation method in order to register the postback or callback data for validation. Can any one let me know on where I am going wrong?

    Read the article

  • ASP.NET MVC 2 "value" in IsValid override in DataAnnotation attribute passed is null, when incorrect

    - by goldenelf2
    Hello to all! This is my first question here on stack overflow. i need help on a problem i encountered during an ASP.NET MVC2 project i am currently working on. I should note that I'm relatively new to MVC design, so pls bear my ignorance. Here goes : I have a regular form on which various details about a person are shown. One of them is "Date of Birth". My view is like this <div class="form-items"> <%: Html.Label("DateOfBirth", "Date of Birth:") %> <%: Html.EditorFor(m => m.DateOfBirth) %> <%: Html.ValidationMessageFor(m => m.DateOfBirth) %> </div> I'm using an editor template i found, to show only the date correctly : <%@ Control Language="C#" Inherits="System.Web.Mvc.ViewUserControl<System.DateTime?>"%> <%= Html.TextBox("", (Model.HasValue ? Model.Value.ToShortDateString() : string.Empty))%> I used LinqToSql designer to create my model from an sql database. In order to do some validation i made a partial class Person to extend the one created by the designer (under the same namespace) : [MetadataType(typeof(IPerson))] public partial class Person : IPerson { //To create buddy class } public interface IPerson { [Required(ErrorMessage="Please enter a name")] string Name { get; set; } [Required(ErrorMessage="Please enter a surname")] string Surname { get; set; } [Birthday] DateTime? DateOfBirth { get; set; } [Email(ErrorMessage="Please enter a valid email")] string Email { get; set; } } I want to make sure that a correct date is entered. So i created a custom DataAnnotation attribute in order to validate the date : public class BirthdayAttribute : ValidationAttribute { private const string _errorMessage = "Please enter a valid date"; public BirthdayAttribute() : base(_errorMessage) { } public override bool IsValid(object value) { if (value == null) { return true; } DateTime temp; bool result = DateTime.TryParse(value.ToString(), out temp); return result; } } Well, my problem is this. Once i enter an incorrect date in the DateOfBirth field then no custom message is displayed even if use the attribute like [Birthday(ErrorMessage=".....")]. The message displayed is the one returned from the db ie "The value '32/4/1967' is not valid for DateOfBirth.". I tried to enter some break points around the code, and found out that the "value" in attribute is always null when the date is incorrect, but always gets a value if the date is in correct format. The same ( value == null) is passed also in the code generated by the designer. This thing is driving me nuts. Please can anyone help me deal with this? Also if someone can tell me where exactly is the point of entry from the view to the database. Is it related to the model binder? because i wanted to check exactly what value is passed once i press the "submit" button. Thank you.

    Read the article

  • Generic collection as a Java method argument

    - by Guido
    Is there any way to make this work in Java? public static void change(List<? extends Object> list, int position1, int position2) { Object obj = list.get(position1); list.set(position1, list.get(position2)); list.set(position2, obj); } The only way I've successfully avoided warnings and errors is this: public static <T> T change(List<T> list, int position1, int position2) { T obj = list.get(position1); list.set(position1, list.get(position2)); list.set(position2, obj); return obj; } but I don't like to be forced to return a value.

    Read the article

  • Cannot create instance of abstract class

    - by SmartestVEGA
    I am trying to compile the following code and i am getting the error: Cannot create instance of abstract class . Please help m_objExcel = new Excel.Application(); m_objBooks = (Excel.Workbooks)m_objExcel.Workbooks; m_objBook = (Excel._Workbook)(m_objBooks.Add(m_objOpt)); m_objSheets = (Excel.Sheets)m_objBook.Worksheets; m_objSheet = (Excel._Worksheet)(m_objSheets.get_Item(1)); // Create an array for the headers and add it to cells A1:C1. object[] objHeaders = {"Order ID", "Amount", "Tax"}; m_objRange = m_objSheet.get_Range("A1", "C1"); m_objRange.Value = objHeaders; m_objFont = m_objRange.Font; m_objFont.Bold=true; // Create an array with 3 columns and 100 rows and add it to // the worksheet starting at cell A2. object[,] objData = new Object[100,3]; Random rdm = new Random((int)DateTime.Now.Ticks); double nOrderAmt, nTax; for(int r=0;r<100;r++) { objData[r,0] = "ORD" + r.ToString("0000"); nOrderAmt = rdm.Next(1000); objData[r,1] = nOrderAmt.ToString("c"); nTax = nOrderAmt*0.07; objData[r,2] = nTax.ToString("c"); } m_objRange = m_objSheet.get_Range("A2", m_objOpt); m_objRange = m_objRange.get_Resize(100,3); m_objRange.Value = objData; // Save the Workbook and quit Excel. m_objBook.SaveAs(m_strSampleFolder + "Book2.xls", m_objOpt, m_objOpt, m_objOpt, m_objOpt, m_objOpt, Excel.XlSaveAsAccessMode.xlNoChange, m_objOpt, m_objOpt, m_objOpt, m_objOpt); m_objBook.Close(false, m_objOpt, m_objOpt); m_objExcel.Quit();

    Read the article

  • How do I change the logged in user to another?

    - by TruMan1
    I would like to change the logged in user to another user temporarily to do some process. For example, say I am logged in as "Joe". In my method, I want to make the logged in user from "Joe" to "SuperUser", do some process, then change the logged in user back to "Joe". Can someone help with this?

    Read the article

  • When the property get and set method has been called?

    - by SmartestVEGA
    i have the following property declaration Public Property IsAreaSelected() As Integer Get Return If(ViewState("IsAreaSelected") Is Nothing, 0, Cint(ViewState("IsAreaSelected"))) End Get Set(ByVal value As Integer) ViewState("IsAreaSelected") = value End Set End Property i want to know when this set and get method will be called ? will it be called when i execute IsAreaSelected() =0 or is there anything like IsAreaSelected().get() or IsAreaSelected().set() ??

    Read the article

  • CruiseControl .Net Plugin Vb.net Error

    - by Brian
    I am trying to make my own Labeller plugin for Cruise Control .Net 1.4.3. I have made a class based on another plug in example but I keep getting an error Class 'AssemblyVersionLabeller' must implement 'Function Generate(integrationResult As IIntegrationResult) As String' for interface 'ThoughtWorks.CruiseControl.Core.ILabeller' Here is my code : Imports Exortech.NetReflector Imports ThoughtWorks.CruiseControl.Core Imports ThoughtWorks.CruiseControl.Core.Util Namespace NetAssembly.CCNet.Label _ Public Class AssemblyVersionLabeller Implements ILabeller Public Sub Run(ByVal result As IIntegrationResult) result.Label = Generate(result) End Sub Public Function Generate(ByVal integrationResult As IIntegrationResult) As String Dim label As String = integrationResult.LastIntegration.Label Return label End Function <ReflectorProperty("prefix", Required:=False)> _ Public Prefix As String = String.Empty End Class End Namespace What am I doing wrong? What have I missed? Background Info: I am using VS2005. I cant use CrusieControl 1.4.4 RC2 (which has an Assembly Labeller) because my source control's plugin (SCM Anywhere) doesnt work with it.

    Read the article

  • Question about migrating from ASP .NET User Controls to .NET 3.5 Master Page technology

    - by Jim McFetridge
    When migrating from an ASP .NET user control -based page with a header, footer, and menu to a Master Page using the same HTML mark-up, is it normal for CSS or javascript behaviors to change slightly? In particular, the submenu bar text now appears run together (which looks like a CSS symptom) and the graphics on the line above it appear to have an incorrect z-order. (The menu operation is javascript-based.) (I tried to paste images here but couldn't.) Also, the site is very large and we've not been given permission to redo the menu for the entire site. This is a forward-only migration. (Because I know that someone will ask.) Assuming that there are no changes in scope, what are the things that I should check? Thanks! Jim

    Read the article

  • showing errors from actions in table-based views

    - by enashnash
    I have a view where I want to perform different actions on the items in each row in a table, similar to this (in, say, ~/Views/Thing/Manage.aspx): <table> <% foreach (thing in Model) { %> <tr> <td><%: thing.x %></td> <td> <% using (Html.BeginForm("SetEnabled", "Thing")) { %> <%: Html.Hidden("x", thing.x) %> <%: Html.Hidden("enable", !thing.Enabled) %> <input type="submit" value="<%: thing.Enabled ? "Disable" : "Enable" %>" /> <% } %> </td> <!-- more tds with similar action forms here, a few per table row --> </tr> <% } %> In my ThingController, I have functions similar to the following: public ActionResult Manage() { return View(ThingService.GetThings()); } [HttpPost] public ActionResult SetEnabled(string x, bool enable) { try { ThingService.SetEnabled(x, enable); } catch (Exception ex) { ModelState.AddModelError("", ex.Message); // I know this is wrong... } return RedirectToAction("Manage"); } In the most part, this is working fine. The problem is that if ThingService.SetEnabled throws an error, I want to be able to display the error at the top of the table. I've tried a few things with Html.ValidationSummary() in the page but I can't get it to work. Note that I don't want to send the user to a separate page to do this, and I'm trying to do it without using any javascript. Am I going about displaying my table in the best way? How do I get the errors displayed in the way I want them to? I will end up with perhaps 40 small forms on the page. This approach comes largely from this article, but it doesn't handle the errors in the way I need to. Any takers?

    Read the article

  • VB.NET ASP.NET Web Application woes (VS 2008)

    - by typoknig
    Hi all, I am making my first web application with ASP.NET and I am having a rough time. I have previously created the application I am working on as a Windows Form application and it works great, but I am having problems with the HTML side of things in the web application. My issues are pretty minor, but very annoying. I have worked with websites before and CSS, but as far as I can tell I do not have direct access to a CSS when creating a web application in VS 2008. My biggest issue is the positioning of components that I have dragged onto the "Default.aspx" form. For instance, how am I supposed to float a panel next to another one if I don't have a CSS, or how am I to correctly position a label?

    Read the article

  • .NET TDD with a Database and ADO.NET Entity Framework - Integration Tests

    - by Brian
    Hello, I'm using ADO.NET entity framework, and am using an AdventureWorks database attached to my local database server. For unit testing, what approaches have people taken to work with a database? Obviously, the database has to be in a pre-defined state of change so that the tests can have some isolation from each other... so I need to be able to run through the inserts and updates, then rollback either between tests or after the batch of tests are done. Any advice? Thanks.

    Read the article

  • executing pages built in 1.1 and 2.0 framework in same website

    - by Technovault
    I am having an application which is built in 1.1 framework.This application is now rebuilt in 2.0 framework but due to some reason we have to use some of the pages of 1.1 framework. So for this we are executing both the applications simultaneously and n carrying out the work using querystrings. So my question can we include pages made in 1.1 and 2.0 framework in one website , if not then please suggest me any other alternative because me method is not that secure... waiting for response ....

    Read the article

  • C# delegate or Func for 'all methods'?

    - by Michel
    Hi, i've read something about Func's and delegates and that they can help you to pass a method as a parameter. Now i have a cachingservice, and it has this declaration: public static void AddToCache<T>(T model, double millisecs, string cacheId) where T : class public static T GetFromCache<T>(string cacheId) where T : class So in a place where i want to cache some data, i check if it exists in the cache (with GetFromCache) and if not, get the data from somewhere, and the add it to the cache (with AddToCache) Now i want to extend the AddToCache method with a parameter, which is the class+method to call to get the data Then the declaration would be like this public static void AddToCache<T>(T model, double millisecs, string cacheId, Func/Delegate methode) where T : class Then this method could check wether the cache has data or not, and if not, get the data itself via the method it got provided. Then in the calling code i could say: AddToCache<Person>(p, 10000, "Person", new PersonService().GetPersonById(1)); AddToCache<Advert>(a, 100000, "Advert", new AdvertService().GetAdverts(3)); What i want to achieve is that the 'if cache is empty get data and add to cache' logic is placed on only one place. I hope this makes sense :) Oh, by the way, the question is: is this possible?

    Read the article

  • MVC4 link automatically redirected to default INDEX page/action even if defined action name with controller

    - by Raj Tamakuwala
    i am creating web mobile application in mvc4. My problem is when I click on particular link in my application,it works well, but sometimes it automatically redirected to INDEX page that is set as default page in global.asax as routes.MapRoute( "Default", // Route name "{controller}/{action}/{id}", // URL with parameters new { controller = "Home", action = "Index", id = UrlParameter.Optional } // Parameter defaults ); Now I don't know why its automatically redirected to INDEX page,even if I have already defined controller and action name where it show redirected as, <a href='@(Url.Action( "ActivityWall", "Home"))' > </a> logically it should redirect to "ActivityWall" page,which it does.but sometime only it goes to INDEX page.then when I clear my cookie problem will again solved but after some time it again start redirecting to INDEX page. I also posted question related to cookies issue yesterday,but I think that is nit main issue. can someone help please ?

    Read the article

  • MSMQ - Message Queue Abstraction and Pattern

    - by Maxim Gershkovich
    Hi All, Let me define the problem first and why a messagequeue has been chosen. I have a datalayer that will be transactional and EXTREMELY insert heavy and rather then attempt to deal with these issues when they occur I am hoping to implement my application from the ground up with this in mind. I have decided to tackle this problem by using the Microsoft Message Queue and perform inserts as time permits asynchronously. However I quickly ran into a problem. Certain inserts that I perform may need to be recalled (ie: retrieved) immediately (imagine this is for POS system and what happens if you need to recall the last transaction - one that still hasn’t been inserted). The way I decided to tackle this problem is by abstracting the MessageQueue and combining it in my data access layer thereby creating the illusion of a single set of data being returned to the user of the datalayer (I have considered the other issues that occur in such a scenario (ie: essentially dirty reads and such) and have concluded for my purposes I can control these issues). However this is where things get a little nasty... I’ve worked out how to get the messages back and such (trivial enough problem) but where I am stuck is; how do I create a generic (or at least somewhat generic) way of querying my message queue? One where I can minimize the duplication between the SQL queries and MessageQueue queries. I have considered using LINQ (but have very limited understanding of the technology) and have also attempted an implementation with Predicates which so far is pretty smelly. Are there any patterns for such a problem that I can utilize? Am I going about this the wrong way? Does anyone have an of their own ideas about how I can tackle this problem? Does anyone even understand what I am talking about? :-) Any and ALL input would be highly appreciated and seriously considered… Thanks again.

    Read the article

< Previous Page | 30 31 32 33 34 35 36 37 38 39 40 41  | Next Page >