Search Results

Search found 13838 results on 554 pages for 'disconnected model'.

Page 344/554 | < Previous Page | 340 341 342 343 344 345 346 347 348 349 350 351  | Next Page >

  • How do I use HTML5's localStorage in a Google Chrome extension?

    - by davidkennedy85
    I am trying to develop an extension that will work with Awesome New Tab Page. I've followed the author's advice to the letter, but it doesn't seem like any of the script I add to my background page is being executed at all. Here's my background page: <script> var info = { poke: 1, width: 1, height: 1, path: "widget.html" } chrome.extension.onRequestExternal.addListener(function(request, sender, sendResponse) { if (request === "mgmiemnjjchgkmgbeljfocdjjnpjnmcg-poke") { chrome.extension.sendRequest( sender.id, { head: "mgmiemnjjchgkmgbeljfocdjjnpjnmcg-pokeback", body: info, } ); } }); function initSelectedTab() { localStorage.setItem("selectedTab", "Something"); } initSelectedTab(); </script> Here is manifest.json: { "update_url": "http://clients2.google.com/service/update2/crx", "background_page": "background.html", "name": "Test Widget", "description": "Test widget for mgmiemnjjchgkmgbeljfocdjjnpjnmcg.", "icons": { "128": "icon.png" }, "version": "0.0.1" } Here is the relevant part of widget.html: <script> var selectedTab = localStorage.getItem("selectedTab"); document.write(selectedTab); </script> Every time, the browser just displays null. The local storage isn't being set at all, which makes me think the background page is completely disconnected. Do I have something wired up incorrectly?

    Read the article

  • Getting unhandled error and connection get lost when a client tries to communicate with chat server in twisted

    - by user2433888
    from twisted.internet.protocol import Protocol,Factory from twisted.internet import reactor class ChatServer(Protocol): def connectionMade(self): print "A Client Has Connected" self.factory.clients.append(self) print"clients are ",self.factory.clients self.transport.write('Hello,Welcome to the telnet chat to sign in type aim:YOUR NAME HERE to send a messsage type msg:YOURMESSAGE '+'\n') def connectionLost(self,reason): self.factory.clients.remove(self) self.transport.write('Somebody was disconnected from the server') def dataReceived(self,data): #print "data is",data a = data.split(':') if len(a) > 1: command = a[0] content = a[1] msg="" if command =="iam": self.name + "has joined" elif command == "msg": ma=sg = self.name + ":" +content print msg for c in self.factory.clients: c.message(msg) def message(self,message): self.transport.write(message + '\n') factory = Factory() factory.protocol = ChatServer factory.clients = [] reactor.listenTCP(80,factory) print "Iphone Chat server started" reactor.run() The above code is running succesfully...but when i connect the client (by typing telnet localhost 80) to this chatserver and try to write message ,connection gets lost and following errors occurs : Iphone Chat server started A Client Has Connected clients are [<__main__.ChatServer instance at 0x024AC0A8>] Unhandled Error Traceback (most recent call last): File "C:\Python27\lib\site-packages\twisted\python\log.py", line 84, in callWithLogger return callWithContext({"system": lp}, func, *args, **kw) File "C:\Python27\lib\site-packages\twisted\python\log.py", line 69, in callWithContext return context.call({ILogContext: newCtx}, func, *args, **kw) File "C:\Python27\lib\site-packages\twisted\python\context.py", line 118, in callWithContext return self.currentContext().callWithContext(ctx, func, *args, **kw) File "C:\Python27\lib\site-packages\twisted\python\context.py", line 81, in callWithContext return func(*args,**kw) --- --- File "C:\Python27\lib\site-packages\twisted\internet\selectreactor.py", line 150, in _doReadOrWrite why = getattr(selectable, method)() File "C:\Python27\lib\site-packages\twisted\internet\tcp.py", line 199, in doRead rval = self.protocol.dataReceived(data) File "D:\chatserverultimate.py", line 21, in dataReceived content = a[1] exceptions.IndexError: list index out of range Where am I going wrong?

    Read the article

  • android httpurlconnection [closed]

    - by user620451
    hi im new android developer i am trying to login to my asterisk server passing my username and password it works good but when i am trying to request anther url to the server after login i get access denied and i now the problem because the login connection has disconnected so i want a way to request to urls the first one is login to the server and the second is to do something else after login please help and thx anyway this is a part of my code i want to request this 2 url url1="http://192.168.1.7:8088/rawman?action=login&username=admin&secret=admin" url2="http://192.168.1.5:8088/rawman?action=updateconfig&reload=yes&srcfilename=users.conf&dstfilename=users.conf&Action-000000=newcat&Cat-000000=6001&Var-000000=&Value-000000=" public void onCreate(Bundle savedInstanceState) { super.onCreate(savedInstanceState); setContentView(R.layout.main); tv1 = (TextView) this.findViewById(R.id.display); ed1 = (EditText) this.findViewById(R.id.editText); bt1 = (Button) this.findViewById(R.id.submit); bt1.setOnClickListener(new OnClickListener() { public void onClick(View view) { { try{ ServerRequest(url1); ServerRequest(url2); } catch(Exception e) { Log.v("Exception", "Exception:"+e.getMessage()); } } } }); } public String ServerRequest(String serverString) throws MalformedURLException, IOException { String newFeed=serverString; StringBuilder response = new StringBuilder(); Log.v("server","server url:"+newFeed); URL url = new URL(newFeed); HttpURLConnection httpconn = (HttpURLConnection) url.openConnection(); if(httpconn.getResponseCode()==HttpURLConnection.HTTP_OK) { BufferedReader input = new BufferedReader( new InputStreamReader(httpconn.getInputStream()), 8192); String strLine = null; while ((strLine = input.readLine()) != null) { response.append(strLine); } input.close(); } tv1.settext(response); return response.toString(); }

    Read the article

  • Threshold of blurry image - part 2

    - by 1''
    How can I threshold this blurry image to make the digits as clear as possible? In a previous post, I tried adaptively thresholding a blurry image (left), which resulted in distorted and disconnected digits (right): Since then, I've tried using a morphological closing operation as described in this post to make the brightness of the image uniform: If I adaptively threshold this image, I don't get significantly better results. However, because the brightness is approximately uniform, I can now use an ordinary threshold: This is a lot better than before, but I have two problems: I had to manually choose the threshold value. Although the closing operation results in uniform brightness, the level of brightness might be different for other images. Different parts of the image would do better with slight variations in the threshold level. For instance, the 9 and 7 in the top left come out partially faded and should have a lower threshold, while some of the 6s have fused into 8s and should have a higher threshold. I thought that going back to an adaptive threshold, but with a very large block size (1/9th of the image) would solve both problems. Instead, I end up with a weird "halo effect" where the centre of the image is a lot brighter, but the edges are about the same as the normally-thresholded image: Edit: remi suggested morphologically opening the thresholded image at the top right of this post. This doesn't work too well. Using elliptical kernels, only a 3x3 is small enough to avoid obliterating the image entirely, and even then there are significant breakages in the digits:

    Read the article

  • ZF2 - How to use the Hydrator/exchangeArray() to populate a nested object

    - by Dominic Watson
    I've got an object with values that are stored in my database. My object also contains another object which is stored in the database using just the ID of it (foreign key). http://framework.zend.com/manual/2.0/en/modules/zend.stdlib.hydrator.html Before the Hydrator/exchangeArray functionality in ZF2 you would use a Mapper to grab everything you need to create the object. Now I'm trying to eliminate this extra layer by just using Hydration/exchangeArray to populate my objects but am a bit stuck on creating the nested object. Should my entity have the Inner object's table injected into it so I can create it if the ID of it is passed to my 'exchangeArray' ? Here are example entities as an example. // Village id, name, position, square_id // Map Square id, name, type Upon sending square_id to my Village's exchangeArray() function. It would get the mapTable and use hydrator to pull in the square using the ID I have. It doesn't seem right to be to have mapper instances inside my entity as I thought they should be disconnected from anything but it's own entity specific parameters and functionality?

    Read the article

  • Organising UI code in .NET forms

    - by sb3700
    Hi I'm someone who has taught myself programming, and haven't had any formal training in .NET programming. A while back, I started C# in order to develop a GUI program to control sensors, and the project has blossomed. I was just wondering how best to organise the code, particularly UI code, in my forms. My forms currently are a mess, or at least seem a mess to me. I have a constructor which initialises all the parameters and creates events. I have a giant State property, which updates the Enabled state of all my form control as users progress through the application (ie: disconnected, connected, setup, scanning) controlled by a States enum. I have 3-10 private variables accessed through properties, some of which have side-effects in changing the values of form elements. I have a lot of "UpdateXXX" functions to handle UI elements that depend on other UI elements - ie: if a sensor is changed, then change the baud rate drop down list. They are separated into regions I have a lot of events calling these Update functions I have a background worker which does all the scanning and analysis. My problem is this seems like a mess, particularly the State property, and is getting unmaintainable. Also, my application logic code and UI code are in the same file and to some degree, intermingled which seems wrong and means I need to do a lot of scrolling to find what I need. How do you structure your .net forms? Thanks

    Read the article

  • Strategies for Synchronizing Data Between a Rails App and iPhone App

    - by jessecurry
    I've written many iPhone Applications that have pulled data from web services and I've worked on synchronizing data between an iPhone App and a Web Application, but I've always felt that there is probably a better way to handle the synchronization. I'd like to know what strategies you have used to synchronize data between your iPhone(read: mobile) Apps and your Rails(read: web) Applications. Are there any strategies that scale particularly well? How have you dealt with large amounts of data? (Do you use paged responses?) How do you make sure that data is not overwritten? Is there a reason to avoid Ruby on Rails? if so, can you suggest an alternative? What is better about the alternative? What strategies have failed? Why do you believe that those strategies failed? I would like to be able to keep all of the data modifications on the server, but the particular application I am about to start work on will need the ability to operate while disconnected from the network. The user will be able to update data on the mobile device and update data through the web application. When the user's mobile device connects to the server any local changes will be pushed to the server.

    Read the article

  • Pre Project Documentation

    - by DeanMc
    I have an issue that I feel many programmers can relate to... I have worked on many small scale projects. After my initial paper brain storm I tend to start coding. What I come up with is usually a rough working model of the actual application. I design in a disconnected fashion so I am talking about underlying code libraries, user interfaces are the last thing as the library usually dictates what is needed in the UI. As my projects get bigger I worry that so should my "spec" or design document. The above paragraph, from my investigations, is echoed all across the internet in one fashion or another. When a UI is concerned there is a bit more information but it is UI specific and does not relate to code libraries. What I am beginning to realise is that maybe code is code is code. It seems from my extensive research that there is no 1:1 mapping between a design document and the code. When I need to research a topic I dump information into OneNote and from there I prioritise features into versions and then into related chunks so that development runs in a fairly linear fashion, my tasks tend to look like so: Implement Binary File Reader Implement Binary File Writer Create Object to encapsulate Data for expression to the caller Now any programmer worth his salt is aware that between those three to do items could be a potential wall of code that could expand out to multiple files. I have tried to map the complete code process for each task but I simply don't think it can be done effectively. By the time one mangles pseudo code it is essentially code anyway so the time investment is negated. So my question is this: Am I right in assuming that the best documentation is the code itself. We are all in agreement that a high level overview is needed. How high should this be? Do you design to statement, class or concept level? What works for you?

    Read the article

  • Socket select() Handling Abrupt Disconnections

    - by Genesis
    I am currently trying to fix a bug in a proxy server I have written relating to the socket select() call. I am using the Poco C++ libraries (using SocketReactor) and the issue is actually in the Poco code which may be a bug but I have yet to receive any confirmation of this from them. What is happening is whenever a connection abruptly terminates the socket select() call is returning immediately which is what I believe it is meant to do? Anyway, it returns all of the disconnected sockets within the readable set of file descriptors but the problem is that an exception "Socket is not connected" is thrown when Poco tries to fire the onReadable event handler which is where I would be putting the code to deal with this. Given that the exception is silently caught and the onReadable event is never fired, the select() call keeps returning immediately resulting in an infinite loop in the SocketReactor. I was considering modifying the Poco code so that rather than catching the exception silently it fires a new event called onDisconnected or something like that so that a cleanup can be performed. My question is, are there any elegant ways of determining whether a socket has closed abnormally using select() calls? I was thinking of using the exception message to determine when this has occured but this seems dirty to me.

    Read the article

  • .NET - Unable to get values from Value property of HtmlInputHidden

    - by user245123
    I have a custom control that inherits from .NET's CompositeControl class. This control overrides the CreateChildControls in order to build its child controls dynamically. I need the page to post back after a couple different javascript events occur on the client side. In order to accomplish this, I create two hidden controls on the page so I can set their values with javascript, submit the page, and read the values out on server side. Here's is the code I use to create these two hiddens: Protected Overrides Sub CreateChildControls() hdEventName = New HiddenField() Controls.Add(hdEventName) hdEventName.ID = "hdEventName" hdEventArgs = New HiddenField() Controls.Add(hdEventArgs) hdEventArgs.ID = "hdEventValue" ' other controls ' ... End Sub When a javascript event occurs I set the value attribute of the two hiddens and submit the page, like so: hdEventName.value = 'EventName'; hdEventArgs.value = 'arg1,arg2'; document.forms[0].submit(); In the OnLoad method of my control, I attempt to check the Value property of the hdEventName and hdEventArgs controls, but it is always empty. However, Page.Request.Form(hdEventName.UniqueID) and Page.Request.Form(hdEventArgs.UniqueID) return correct values. The actual HTML in the markup also shows correct values after the page posts back. Why is the Value property of the HtmlInputHiddens disconnected from the actual value that appears on the client?

    Read the article

  • java.lang.ClassNotFoundException: com.mysql.jdbc.Driver When run jar file

    - by user1024858
    Hi all, Connection conn = null; String url = "jdbc:mysql://localhost:3306/"; String dbName = "test"; String driver = "com.mysql.jdbc.Driver"; String userName = "root"; String password = "admin"; try { Class.forName(driver).newInstance(); conn = DriverManager.getConnection(url+dbName,userName,password); System.out.println("Connected to the database"); conn.close(); System.out.println("Disconnected from database"); } catch (Exception e) { e.printStackTrace();} I run in eclipse it's ok, but i built to jar file and run on command line java -jar Test.jar i get this error: java.lang.ClassNotFoundException: com.mysql.jdbc.Driver at java.net.URLClassLoader$1.run(Unknown Source) at java.net.URLClassLoader$1.run(Unknown Source) at java.security.AccessController.doPrivileged(Native Method) at java.net.URLClassLoader.findClass(Unknown Source) at java.lang.ClassLoader.loadClass(Unknown Source) at sun.misc.Launcher$AppClassLoader.loadClass(Unknown Source) at java.lang.ClassLoader.loadClass(Unknown Source) at java.lang.Class.forName0(Native Method) at java.lang.Class.forName(Unknown Source) Please help me how to fix it. Thanks!!!

    Read the article

  • How to delete a row from a typed dataset and save it to a database?

    - by Zingam
    I am doing this as a small project to learn about disconnected and connected models in .NET 4.0 and SQL Server 2008 R2. I have three tables: Companies (PK CompanyID) Addresses (PK AddressID, FK CompanyID) ContactPersons (PK ContactPersonID, FK CompanyID) CompanyID is assigned manually by the users. The other IDs are auto-generated. Companies has a one-to-many relationship with ContactPerson. I have set any changes to cascade. I display all records in Companies in a DataGridView and when a row is clicked, the corresponding records in ContactPersons are displayed in a second DataGridView. I have successfully implemented updating and inserting new records but I completely fail in my attempts to delete rows and save the changes to the database. I us a typed dataset. If I use this: DataRow[] contactPersonRows = m_SoldaCompaniesFileDataSet.ContactPersons.Select("ContactPersonID = " + this.m_CurrentContactPerson.ContactPersonID); m_SoldaCompaniesFileDataSet.ContactPersons.Rows.Remove(contactPersonRows[0]); The records are displayed properly in the DataGridView but are not saved in the database later. If I use this: DataRow row = m_SoldaCompaniesFileDataSet.ContactPersons.Rows.Find(this.m_CurrentContactPerson.ContactPersonID); row.Delete(); The records are set but I get an exeception: DeletedRowInaccessibleException, when I try to refresh the DataGridView. The exception pop-s up in the auto-generated dataset.design file. I am pretty much stuck at this point since yesterday. I cannot find anything anywhere that remotely resembles my problem. And I cannot understand actually what is going on.

    Read the article

  • SQL - Query range between two dates (NON-VBA)

    - by Mohgeroth
    I see various topics on this around stack overflow but none that fit the contect of MS-Access... Given a starting date and an ending date, is there a way through SQL to return records for each given month within the time frame? EG: Between #1/1/2010# and #12/31/2010# results #1/4/2010# #1/11/2010# ..... #12/27/2010# Restrictions MS-Access 2003 :No Case/Loops inside the SQL (IIF statements are good) This is a view only, NO VBA will be used since the data will not be tampered with. Disconnected recordset is my last option. I would prefer to find out theres some way to call your customized functions in the SQL to help return these values... some class stored on a global scope while you iterate through this date range maybe... Is this possible? I see many no's, but if there was a way to pass a value into a function I could find a way to make this work. Sad that I don't have a way to simulate a stored procedure without using a d/c recordset, at least that I know of... any experts out there know a way?

    Read the article

  • Java if/else behaving strangely

    - by Alex
    I'm a real newbie to java, so please excuse me if this is a hopelessly straightforward problem. I have the following from my java game server: // Get input from the client DataInputStream in = new DataInputStream (server.getInputStream()); PrintStream out = new PrintStream(server.getOutputStream()); disconnect=false; while((line = in.readLine().trim()) != null && !line.equals(".") && !line.equals("") && !disconnect) { System.out.println("Received "+line); if(line.equals("h")){ out.println("h"+EOF); // Client handshake System.out.println("Matched 1"); }else if (line.equals("<policy-file-request/>")) { out.println("..."+EOF); // Policy file System.out.println(server.getInetAddress()+": Policy Request"); disconnect=true; System.out.println("Matched 2"); }else if(line.substring(0,3).equals("GET")||line.substring(0,4).equals("POST")){ out.println("HTTP/1.0 200 OK\nServer: VirtuaRoom v0.9\nContent-Type: text/html\n\n..."); // HTML status page disconnect=true; System.out.println("Matched 3"); } else { System.out.println(server.getInetAddress()+": Unknown command, client disconnected."); disconnect=true; System.out.println("Matched else"); } } server.close(); First of all, the client sends an "h" packet, and expects the same back (handshake). However, I want it to disconnect the client when an unrecognised packet is received. For some reason, it responds fine to the handshake and HTML status request, but the else clause is never executed when there's an unknown packet. Thanks

    Read the article

  • Detecting TCP dropout over an unreliable network

    - by yx
    I am doing some experimentation over an unreliable radio network (home brewed) using very rudimentary java socket programming to transfer messages back and forth between the end nodes. The setup is as follows: Node A --- Relay Node --- Node B One problem I am constantly running into is that somehow the connection drops out and neither Node A or B knows that the link is dead, and yet continues to transmit data. The TCP connection does not time out either. I have added in a heartbeat message that causes a timeout after a while, but I still would like to know what is the underlying cause of why TCP does not time out. Here are the options I am enabling when setting up a socket: channel.socket().setKeepAlive(false); channel.socket().setTrafficClass(0x08); // for max throughput This behavior is strange since it is totally different than when I have a wired network. On a wired network, I can simulate a disconnected connection by pulling out the ethernet cord, however, once I plug the cord back in, the connection becomes restablished and messages begin to be passed through once more. On the radio network, the connection is never reestablished and once it silently dies, the messages never resume. Is there some other unknown java implentation or setting for a socket that I can use, also, why am I seeing this behavior in the first place? And yes, before anyone says anything, I know TCP is not the preffered choice over an unreliable network, but in this case I wanted to ensure no packet loss.

    Read the article

  • BluetoothChat doesn't work

    - by jes
    Hello I want to make conversation between android devices. I use BluetoothChat to do this but it doesn't work I can't read correctly data from another device. Conversation is : Me: privet Device: p Device: rivet Can you help me? private class ConnectedThread extends Thread { private final InputStream mmInStream; private final OutputStream mmOutStream; public ConnectedThread(BluetoothSocket socket) { Log.d(TAG, "create ConnectedThread"); mmSocket = socket; //InputStream tmpIn = null; OutputStream tmpOut = null; BufferedInputStream tmpIn=null; int INPUT_BUFFER_SIZE=32; // Get the BluetoothSocket input and output streams try { //tmpIn = socket.getInputStream(); tmpOut = socket.getOutputStream(); tmpIn = new BufferedInputStream(socket.getInputStream(),INPUT_BUFFER_SIZE); } catch (IOException e) { Log.e(TAG, "temp sockets not created", e); } mmInStream = tmpIn; mmOutStream = tmpOut; } public void run() { Log.i(TAG, "BEGIN mConnectedThread"); byte[] buffer = new byte[1024]; int bytes; // Keep listening to the InputStream while connected while (true) { try { // Read from the InputStream bytes = mmInStream.read(buffer); // Send the obtained bytes to the UI Activity mHandler.obtainMessage(BluetoothChat.MESSAGE_READ, bytes, -1, buffer) .sendToTarget(); } catch (IOException e) { Log.e(TAG, "disconnected", e); connectionLost(); break; } } }

    Read the article

  • Clustered Graphs Visualization Techniques

    - by jameszhao00
    I need to visualize a relatively large graph (6K nodes, 8K edges) that has the following properties: Distinct Clusters. Approximately 50-100 Nodes per cluster and moderate interconnectivity at the cluster level Minimal (5-10 inter-cluster edges per cluster) interconnectivity between clusters Let global edge overlap = The edge overlaps caused by directly visualizing a graph of Clusters = {A, B, C, D, E}, Edges = {Pentagram of those clusters, which is non-planar by the way and will definitely generate edge overlap if you draw it out directly} Let Local Edge Overlap = the above but { A, B, C, D, E } are just nodes. I need to visualize graphs with the above in a way that satisfies the following requirements No global edge overlap (i.e. edge overlaps caused by inter-cluster properties is not okay) Local edge overlap within a cluster is fine Anyone have thoughts on how to best visualize a graph with the requirements above? One solution I've come up with to deal with the global edge overlap is to make sure a cluster A can only have a max of 1 direct edge to another cluster (B) during visualization. Any additional inter-cluster edges between cluster A - C, A - D, ... are disconnected and additional node/edges A - A_C, C - C_A, A - A_D, D - D_A... are created. Anyone have any thoughts?

    Read the article

  • IIS7.5 Domain Account Application Pool Identity for SQL Server Authentication

    - by Gareth Hill
    In Windows Server 2003/IIS6 land we typically create an app pool that runs as the identity of an AD account created with minimal privileges simply for that purpose. This same domain user would also be granted access to SQL Server so that any ASP.NET application in that app pool would be able to connect to SQL Server with Integrated Security=SSPI. We are making a brave move to the world of Windows Server 2008 R2/IIS7.5 and are looking to replicate this model, but I am struggling with how to make the application pool in IIS7.5 run as the identity of an AD account? I know this sounds simple and hopefully it is, but my attempts so far have been fruitless. Should the application pool identity be a 'Custom account' for a domain account? Does the domain account need to be added to any groups?

    Read the article

  • Could not find DHCP daemon to get information on Belkin G Wifi Router

    - by Anirudh Goel
    I am using a Belkin G Wireless Router F5D7234, and i have a DSL connection with only a ethernet cable. So i connected the cable to the Modem port and allowed it to use Dyanmic IP, it worked successfully and an ip was assigned to it and multiple computers could connect to it and browse. But after some time the power went off and after then upon rebooting it is taking about half hour to get an IP address. Upon seeing the log i see this entry repeatedly 07/02/2010 23:22:34 DHCP Client: [WAN]Could not find DHCP daemon to get information 07/02/2010 23:22:32 DHCP Client: [WAN]Send Discover 07/02/2010 23:22:30 DHCP Client: [WAN]Send Discover 07/02/2010 23:22:28 DHCP Client: [WAN]Send Discover 07/02/2010 23:22:26 DHCP Client: [WAN]Send Discover 07/02/2010 23:22:26 DHCP Client: [WAN]Could not find DHCP daemon to get information 07/02/2010 23:22:24 DHCP Client: [WAN]Send Discover 07/02/2010 23:22:22 DHCP Client: [WAN]Send Discover 07/02/2010 23:22:20 DHCP Client: [WAN]Send Discover 07/02/2010 23:22:18 DHCP Client: [WAN]Send Discover Any idea what i can do? I tried using another belkin router of same model and make and there also i faced the same problem.

    Read the article

  • Running Best Practice Analyzer on Windows 2012 yields error "Result file has not yet been generated"

    - by mhildreth
    Whenever I run the Best Practice Analyzer on a Windows 2012 server with IIS installed, I receive the error: "There has been a Best Practice Analyzer error for Model Id 'Microsoft/Windows/WebServer'. The Result file has not yet been generated. Please perform the scan first and try again." I'm doing this from the "Local Server" section of the Server Manager. I'm logged in as with a domain credential that has administrative rights on the server. I don't know how to generate the result file or where it would be located. I have 4 servers, all with IIS and this is happening on all of them. The servers are practically brand new so there isn't anything really exceptional about their setup. Any suggestions on how to generate the result file? Thanks in advance.

    Read the article

  • Power cycles on/off 3 times before booting properly from cold start, no other issues (New System)

    - by James
    Relevant Specs: Sapphire 5850, core i7 920, Seasonic x750 power supply, ECS X58B-A2 mobo. From a cold boot, meaning all power totally disconnected at the wall, the system will power on for less than a second and then power off completely. After two seconds of being powered off this will repeat and on the third "attempt" the computer will boot. To be very specific here is what happens: The power is turned on at the wall and on the psu, the orange stdby LED on the mobo is illuminated but the system is 'off'. I hit the power button on the case or on the mobo itself I hear the relay (?) in the psu closing The case light comes on and the mobo power light comes on. The fans start rotating. Immediately after this the I hear some relay click - the power lights extinguish, the fans stop, the stdby light remains on. Less than 2 seconds pass and the cycle repeats without any intervention from me. On the third attempt it boots normally and the machine runs perfectly. If I do a soft reboot or a full shutdown the computer starts normally the next time. It's only if I pull the power cord or flick the switch off on the PSU that I get the cycling again. Basically any time the stdby light on the mobo goes out. I have removed the graphics card and I get the same problem. I have removed the PSU, hotwired it to the ON position and verified voltages on all lines. The relay does not cycle when I do this. If I connect only the 24 pin ATX connector to the mobo and not the 8 pin ATX12V / CPU connector then I will not get the cycling, the fans run, the power light stays on, but obviously the system can't boot. Disconnecting all fans has no effect on the problem. My feeling it that it's something to do with the motherboard like a capacitor that's taking a long time to charge because it's leaking or something along those lines. But I can't imagine what could be 'wrong' with it and only manifest itself as a problem under these very specific circumstances. Any ideas? Thanks.

    Read the article

  • Getting VMWare ESXi 5.0.0 with RAID using the Intel X79 chipset to work

    - by Deleted
    I have bought a new server where I use the motherboard ASUS P9X79 WS X79 S-2011 ATX. It will be used for virtualization, preferably using VMware vSphere Hypervisor™ (ESXi) if I can get the RAID on my motherboard working with VMWare (it does not detect it). The motherboard has the Intel® X79 chipset, which for RAID controller means vendor ID 8086 (Intel) and model ID 2826. When I boot the ESXi 5.0.0 installation media from my flash drive I can not see drives in the RAID5 set I created. Questions: Is there a VIB file for the RAID controller I can use? I have found one article at http://www.intel.com/support/motherboards/server/sb/CS-033313.htm on getting RAID to work with some Intel controllers, it lists 9 integrated RAID modules it is comptabile with. However, there is no mention of the X79 chipset.

    Read the article

  • Missing Setup->VLAN on DD-WRT Web GUI?

    - by leeand00
    Please note that I've already posted this question on the dd-wrt forums. I am using "DD-WRT v24-sp2 (08/07/10) std" on a WZR-HP-G300NH model Buffalo router. I've found a number of tutorials online that talk about using Setup-VLAN on the menu system of the GUI interface to configure VLANs, but on my own router, it appears that VLAN configuration is located elsewhere; mainly in the Setup-Networking-VLAN Tagging section of the GUI. I would gladly just use the bash shell to configure the vlans on the router, but every tutorial I read refers to "changing the gui to reflect the changes made in the bash prompt". Are there any tutorials or documentation that you are aware of that that refer to the Setup-Networking-VLAN Tagging GUI portion of my router?

    Read the article

  • Fedora 12 Wireless problems (Intel Wireless 4965AGN Card)

    - by Ninefingers
    Hi All, I'm having an interesting experience with my wireless card at the moment. Basically, it does like this: I connect to the local wireless network (netgear router) It works, briefly, allowing me to browse a webpage or maybe two, if I'm lucky. It then stops working / sending any packets, whilst reported still connected. Now, me being me I've had a look to see what I can find. wpa_supplicant.log looks like this: Trying to associate with valid_mac:a2:30 (SSID='vennardwireless' freq=2462 MHz) Associated with valid_mac:a2:30 WPA: Key negotiation completed with valid_mac:a2:30 [PTK=CCMP GTK=TKIP] CTRL-EVENT-CONNECTED - Connection to valid_mac:a2:30 completed (reauth) [id=0 id_str=] CTRL-EVENT-DISCONNECTED - Disconnect event - remove keys So that's working fine. dmesg | grep "*iwl*" spits out this: iwlagn: Intel(R) Wireless WiFi Link AGN driver for Linux, 1.3.27kds iwlagn: Copyright(c) 2003-2009 Intel Corporation iwlagn 0000:03:00.0: PCI INT A -> GSI 17 (level, low) -> IRQ 17 iwlagn 0000:03:00.0: setting latency timer to 64 iwlagn 0000:03:00.0: Detected Intel Wireless WiFi Link 4965AGN REV=0x4 iwlagn 0000:03:00.0: Tunable channels: 13 802.11bg, 19 802.11a channels iwlagn 0000:03:00.0: irq 32 for MSI/MSI-X phy0: Selected rate control algorithm 'iwl-agn-rs' iwlagn 0000:03:00.0: firmware: requesting iwlwifi-4965-2.ucode iwlagn 0000:03:00.0: loaded firmware version 228.61.2.24 Registered led device: iwl-phy0::radio Registered led device: iwl-phy0::assoc Registered led device: iwl-phy0::RX Registered led device: iwl-phy0::TX iwlagn 0000:03:00.0: iwl_tx_agg_start on ra = 00:24:b2:32:a3:30 tid = 0 iwlagn 0000:03:00.0: iwl_tx_agg_start on ra = 00:24:b2:32:a3:30 tid = 0 So that's working too. I can also ping 192.168.0.1 -I wlan0 and arping 192.168.0.1 -I wlan0 the router until the network falls over. uname -r:2.6.32.10-90.fc12.x86_64. Laptop is a Core2 Duo (2Ghz) with 3GB RAM. Other symptoms I've noticed are that wireshark freezes when I capture on the "broken" interface until I disconnect. Am using networkmanager as per normal. Stupidly, I can connect to the same router via eth0/a cat6 cable just fine. Everyone else can connect to the AP fine (from Windows). Yes, I'm sat right next to it and not trying to access a hotspot the other side of the world. Any ideas? Is this a broken update? (I intend to reboot and test an older kernel later)? Anyone else come across this? Edit: iwconfig wlan0 rate auto is the settings I'm using for rates. Also, according to networkmanager the network is still connected. Thanks for any pointers / advice.

    Read the article

  • xfx 680i motherboard failure?

    - by Ian
    At some point last night we must have had a blip in our power, as the stove clock was blinking like it would had their been... a blip in the power. When I came into my office this morning, my desktop computer was powered down and would not turn on. Cracking the case, I can see a small blue blinking light on the front right corner of the motherboard. Unplugging the power from the PSU causes the blinking to stop. Plugging in the power causes the blinking to resume. Pressing the power button does nothing. Does anyone know what this blinking blue light means? I'm mostly curious now if it's the motherboard that has gone bad, or the power supply. I don't have any other desktop parts to use to troubleshoot these components. Any ideas? My motherboard is an XFX NFORCE 680I SLI INTEL SOCKET 775 DDR2 ( Model #: MB-N680-ISH9 )

    Read the article

< Previous Page | 340 341 342 343 344 345 346 347 348 349 350 351  | Next Page >