Search Results

Search found 6565 results on 263 pages for 'svcutil exe'.

Page 37/263 | < Previous Page | 33 34 35 36 37 38 39 40 41 42 43 44  | Next Page >

  • Cisco Call Manager adding 7945's

    - by Will
    Hello we currently have a call manager settup (older we are working on upgrading it) but for now we are looking to add 7945 IP phones. We currently have 7960's all over the place, but we can't get these new anymore. Here is the info about our call manager ace.dll 5.2.5.0 CCM4.1(3) aced.dll CCM4.1(3) AdministrativeReportingTool.exe 4.1(0.45) 4.1(3)sr4d Apache Tomcat 4.1 CCM4.1(3) ASTIsapi.dll 3.3.2.0 4.1(3)sr4d AudioTranslator.exe 4.0.0.3 CCM4.1(3) Aupair.exe 4.1.3.10472 4.1(3)sr4d AupairChangeNotify.dll 4.1.0.11 CCM4.1(3) AuthFilt.dll 4.0.0.0 4.1(3)sr4d AVVIDCustomerDirectoryConfigurationPlugin.exe 4.1.0.17(0) CCM4.1(3) bootp.exe 2.0.2.2 CCM4.1(3) BulkAdministrationTool.exe 5.1(4c) 4.1(3)sr4d CallBackService.exe 3.3.2.3 4.1(3)sr4d ccm.exe 4.1.3.17472 4.1(3)sr4d CcmPerfMon.dll 4.1(3)sr4d CCNTEST.EXE CCM4.1(3) cdpintf.dll 4.0.0.0 CCM4.1(3) Cisco CallManager 4.1(3)sr4d 4.1(3)sr4d One of the admins recommenced downloading a device pack, which we did. However when we ran it on the call manager server it gave the error "unable to read script" Any recommendations on how to get these phones working with our Call Manager? Thank you.

    Read the article

  • Cannot set ILMerge path to console

    - by KMC
    I install ILMerge.exe; path is C:\Program Files\Microsoft\ILMerge\ILMerge.exe. I want to set the command to the Path so I can type ilmerge anywhere to use the application. I googled and tried all the following but none works: setx -m ilmerge;C:\Program Files\Microsoft\ILMerge\ILMerge.exe setx -M ilmerge;C:\Program Files\Microsoft\ILMerge\ILMerge.exe setx -m %PATH%;C:\Program Files\Microsoft\ILMerge\ILMerge.exe setx /S system /U administrator ilmerge;C:\Program Files\Microsoft\ILMerge\ILMerge.exe I then tried to add, the GUI's Environment Variables, click New and input the variable "ilmerge" and value "C:\Program Files\Microsoft\ILMerge\ILMerge.exe". But in command prompt and type in ilmerge, still gives me 'ilmerge' is not recognized as an internal or external command, operable program or bath file. Why something as basic as setting a path that confusing..

    Read the article

  • procdump on w3wp.exe: Only part of a ReadProcessMemory or WriteProcessMemory request was completed.

    - by JakeS
    I'm having a problem with an IIS application that occasionally spikes up in CPU usage, and am trying to use procdump to get a memory dump for examination. I'm running "procdump.exe -64 -mA 9999" where 9999 is the pid of the process. But every time I do it, I get an error: Only part of a ReadProcessMemory or WriteProcessMemory request was completed. Doing this also recycles the apppool, relieving the CPU spike, so I can't keep trying until I get it right. Does anyone know what is going wrong?

    Read the article

  • What's causing Remote Access error 807 using rasdial.exe to connect to a PPTP VPN?

    - by Dylan Beattie
    I'm using rasdial.exe to connect an offsite server to our VPN. Remote box is a Windows 2008 x64 server; the VPN host at this end is a Watchguard Firebox x750e running Fireware 10.2 It connects fine about 20-30% of the time. The rest of the time I get: Remote Access error 807 - The network connection between your computer and the VPN server was interrupted. This can be caused by a problem in the VPN transmission and is commonly the result of internet latency or simply that your VPN server has reached capacity. Please try to reconnect to the VPN server. If this problem persists, contact the VPN administrator and analyze quality of network connectivity. For more help on this error: Type 'hh netcfg.chm' In help, click Troubleshooting, then Error Messages, then 807 The VPN isn't full, and it's 100Mb dedicated fibre on both ends so I can't believe it's a connectivity issue - especially since I'm RDP'ed into the remote box whilst trying to do this! Any bright ideas as to what might be causing the problem? Thanks, Dylan

    Read the article

  • Wix light.exe : error LGHT0001: The system cannot open the device or file specified.

    - by Angelo
    Today we build our product with MSBuild /m to build with multiprocess. Before we do a change to heat some files in pre-build event, build with MSBuild multiprocess can be success. Now build is failed with following exception: 124light.exe : error LGHT0001: The system cannot open the device or file specified. (Exception from HRESULT: 0x8007006E) [...MSI.wixproj] Exception Type: System.IO.FileLoadException Stack Trace: at Microsoft.Tools.WindowsInstallerXml.MergeMod.IMsmMerge2.OpenModule(String fileName, Int16 language) at Microsoft.Tools.WindowsInstallerXml.Binder.MergeModules(String tempDatabaseFile, Output output, FileRowCollection fileRows, StringCollection suppressedTableNames) at Microsoft.Tools.WindowsInstallerXml.Binder.BindDatabase(Output output, String databaseFile) at Microsoft.Tools.WindowsInstallerXml.Binder.Bind(Output output, String file) at Microsoft.Tools.WindowsInstallerXml.Tools.Light.Run(String[] args) (Link target) - light.exe : error LGHT0001: The system cannot open the device or file specified. (Exception from HRESULT: 0x8007006E) [...Msi.wixproj] using Wix 3.8

    Read the article

  • C#.NET framework 3.5 SP1: satellite assemblies and FullTrust issues when the exe is on the network.

    - by leo
    Hi, I'm executing my .NET app from a network share. Since framework 3.5 SP1, and as explained here: http://blogs.msdn.com/shawnfa/archive/2008/05/12/fulltrust-on-the-localintranet.aspx, the main exe and all the DLLs located in the same folder (but not subfolders) are granted with FullTrust security policy. My problem is that I have subfolders for satellite assemblies with localized strings. Namely, I have: 1) FOLDER\APP.EXE 2) FOLDER\A whole bunch of DLLs 3) FOLDER\LANGUAGE1\Satellite assemblies 4) FOLDER\LANGUAGE2\Satellite assemblies 1 and 2 are automatically granted with FullTrust. 3 and 4 are not and my application is really slow because of that. Is there a way to grant 3 & 4 FullTrust security policy at runtime, since the application running has FullTrust? If not, is there a clean way to have satellite assemblies merged into only one DLL? Thanks a lot.

    Read the article

  • F# PowerPack 2.0.0.0 issue: The task ..."…\fslex.exe" is invalid

    - by Roman Kuzmin
    I have upgraded F# PowerPack today to the latest 2.0.0.0 and tried to rebuild the MiniCalc sample from here: http://achrissmith.blogspot.com/2010/04/fslex-and-fsyacc-examples-updated.html If I build it in VS 2010 it fails with the message: C:\Program Files\MSBuild\FSharp\1.0\FSharp.PowerPack.targets(32,3): error MSB6004: The specified task executable location "C:\Program Files\Microsoft Visual Studio 10.0\Common7\IDE\fslex.exe" is invalid. If I build it from the command line by MSBuild it complains about missing C:\Windows\Microsoft.NET\Framework\v4.0.30319\fslex.exe The problem is kind of “fixed” if I copy fslex and fsyacc to that both directories, so after that I can build from the command line and from VS 2010. But it does not look like a right way to solve the problem. What is the right way? EDIT: The same issue is true for the PowerPack sample from sources: May2010\workyard\tests\LexAndYaccMiniProject. Now (after the trick I have done) it is built fine, too.

    Read the article

  • Embedding icon in .exe with py2exe, visible in Vista?

    - by WindPower
    Hello, I've been trying to embed an icon (.ico) into my "compyled" .exe with py2exe. Py2Exe does have a way to embed an icon: windows=[{ 'script':'MyScript.py', 'icon_resources':[(1,'MyIcon.ico')] }] And that's what I am using. The icon shows up fine on Windows XP or lower, but doesn't show at all on Vista. I suppose this is because of the new Vista icon format, which can be in PNG format, up to 256x256 pixels. So, how can I get py2exe to embed them into my executable, without breaking the icons on Windows XP? I'm cool with doing it with an external utility rather than py2exe - I've tried this command-line utility to embed it, but it always corrupts my exe and truncates its size for some reason.

    Read the article

  • How to use an out-of-process COM server without its tlb file

    - by Dbger
    It is about Window COM component. Server.exe: an 32bit out-of-process COM server CLSID_Application: The GUID of a COM object in Server.exe Client.exe: a 64bit client application which use Server.exe in a registry-free way. As we know, an exe can't be used as a registry-free COM component, to mimic such behavior, I start the Server.exe process myself by providing the exact path: CreateProcess("Server.exe") IClassFactory* pFactory = CoGetClassObject(CLSID_Application) pFactory-CreateInstance(ppAppObject); It works if I have the Server.tlb registred, but after unregister Server.tlb, it just failed to create the ppAppObject, even though I embed manifest into both Server.exe and Client.exe: <assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0"> <file name="Server.tlb"> <typelib tlbid="{DAC4A4C9-F84C-4F05-A7DC-E152869499F5}" version="1.0" helpdir=""></typelib> </file> <comInterfaceExternalProxyStub name="IApplication" iid="{D74208EA-71C2-471D-8681-9760B8ECE599}" tlbid="{DAC4A4C9-F84C-4F05-A7DC-E152869499F5}" proxyStubClsid32="{00020424-0000-0000-C000-000000000046}"></comInterfaceExternalProxyStub> </assembly> Do you have any idea on this? Edit: It turns out that it really works if I specify tlbid for interfaces, and embed the manifest to both exe

    Read the article

  • What are the differences between MSI and EXE installers, and which should I choose?

    - by Jared Harley
    I am working on an installer for a new version of my project (C#). Previously, I've used Inno Setup to create .exe files for installing my projects on other computers in the workplace. While reading through some tutorials, though, I came across Windows Installer XML, which uses XML files to build a .msi installer. My project will be available on a network share that all the employees have access to so they can install the software (I'm currently working on an update checker as well) What are the major differences between .exe and .msi installers? Why would I want to chose one over the other? Would either make more sense given my specific environment? I found some of the information at this question, but there was not a lot of information.

    Read the article

  • Problem reading from the StandarOutput from ftp.exe. Possible System.Diagnostics.Process Framework b

    - by SoMoS
    Hello, I was trying some stuff executing console applications when I found this problem handling the I/O of the ftp.exe command that everybody has into the computer. Just try this code: m_process = New Diagnostics.Process() m_process.StartInfo.FileName = "ftp.exe" m_process.StartInfo.CreateNoWindow = True m_process.StartInfo.RedirectStandardInput = True m_process.StartInfo.RedirectStandardOutput = True m_process.StartInfo.UseShellExecute = False m_process.Start() m_process.StandardInput.AutoFlush = True m_process.StandardInput.WriteLine("help") MsgBox(m_process.StandardOutput.ReadLine()) MsgBox(m_process.StandardOutput.ReadLine()) MsgBox(m_process.StandardOutput.ReadLine()) MsgBox(m_process.StandardOutput.ReadLine()) This should show you the text that ftp sends you when you do that from the command line: Los comandos se pueden abreviar. Comandos: ! delete literal prompt send ? debug ls put status append dir mdelete pwd trace ascii disconnect mdir quit type bell get mget quote user binary glob mkdir recv verbose bye hash mls remotehelp cd help mput rename close lcd open rmdir Instead of that I'm getting the first line and 3 more with garbage, after that the call to ReadLine block like if there was no data available. Any hints about that?

    Read the article

  • How do I make an exe into a service on Windows?

    - by user3677994
    I recently made an application that has multiple parts. One of the parts is a networking tool - it always starts with the OS, and it never displays any sort of message. It does, however, start an incredibly irritating console, which is impossible to get rid of without closing the program itself (please just accept this one as given). I have decided to work around this problem by starting the program (it's a *.exe) as a service, thus stopping it from showing up at all. As the application will be distributed to various computers (hence the need for a networking tool in the first place). I need a way to make this program install as a service (so, I don't really want answers that tell me to go through a series of menus on the Control Panel or download a 3rd-party application that has to stay on whichever computer the service will run on). How can I do this?

    Read the article

  • 256 SSD / 2TB Internal drive, i7, 16GB RAM.. explorer.exe still slow

    - by web_dvlp_sd
    OK, so I just got done tweaking my brand new PC and explorer.exe still manages to be sluggish not as snappy as I'd like or expected at all. Specs are i7 4th gen processor, 16GB RAM, windows 7 64 home premium on 256GB SSD, secondary internal 2TB drive. I assumed system would be lightning fast, been doing a bunch of researching and switched out a lot of different settings including enabling/disabling indexing, turning pagefile on/off or placing it on separate drive, turning folder optimization options on/off.. changes have been minimal or none at all. Any further advice or anything I might be missing, besides a new/repair install? PC is literally 3 days old I don't feel like I need a new install at all

    Read the article

  • crash with CoUnintailize() api of COM

    - by jbp117
    My main process(main.exe) initilaized COM library and created a thread which creates a new process(p1.exe) this new process is again initializing COM library and after making all references as zero unintialized COM here.. the unintailezed COM in the main process (i.e main.exe) also.... When i run p1.exe individually it is successful.. but it is crashing when i create a process for p1.exe from main.exe

    Read the article

  • crash with CoUnintialize() api of COM

    - by jbp117
    My main process(main.exe) initilaized COM library and created a thread which creates a new process(p1.exe) this new process is again initializing COM library and after making all references as zero unintialized COM here.. the unintailezed COM in the main process (i.e main.exe) also.... When i run p1.exe individually it is successful.. but it is crashing when i create a process for p1.exe from main.exe

    Read the article

  • Where does Windows 8 put the exe of the default browser for Modern UI?

    - by avirk
    I was trying to some hack with Win-8 and I found something which is really gonna out my mind. When I set the default browser to the IE then its icon become Modern UI and I can't see the option Open file location at the bottom when I select it by right click. But if I don't set it default then it became a desktop version icon and show up the option when I select it. Same is for the Google Chrome when I checked it. IE icon when it is not set to default, I can see the option open file location. Google Chrome icon when it is set to default. Google Chrome of desktop version when it is set to default. So my question is where does Modern UI keep exe of the default browser? And why the default browser has Modern UI icon and non-default browser has desktop version icon.

    Read the article

  • Is there any explorer.exe problem in windows 7 ?

    - by sml
    s += "<p style=\"text-align: left;\"><a href=\"javascript:window.print()\">PRINT</a></p>"; System.IO.File.WriteAllText(@"CheckForm.html", s); System.Diagnostics.ProcessStartInfo startInfo = new System.Diagnostics.ProcessStartInfo(); startInfo.FileName = "explorer.exe"; startInfo.Arguments = "CheckForm.html"; System.Diagnostics.Process.Start(startInfo); I'm having a trouble when I tried to open my c# windows application in windows 7 otherwise there is no problem. I couldn't open explorer.exe in Windows 7 with above code. Any suggestions?

    Read the article

  • How do you configure ConEmu to run cmd.exe as an Administrator from an Explorer integration?

    - by bentayloruk
    I am trying to add a ConEmu Here - Explorer context menu integration entry for the Visual Studio 2012 command prompt. I want the shortcut to Run as Administrator. I am not sure of the right way to do this in ConEmu. I am using the following Command (which works but obviously not as Admin): cmd.exe /k ""C:\Program Files (x86)\Microsoft Visual Studio 11.0\VC\vcvarsall.bat"" x86 What is the correct way to configure ConEmu to run this as Administrator? If there is not a correct way, how should I adjust the command to make this work?

    Read the article

  • Where is the method call in the EXE file?

    - by Victor Hurdugaci
    Introduction After watching this video from LIDNUG, about .NET code protection http://secureteam.net/lidnug_recording/Untitled.swf (especially from 46:30 to 57:30), I would to locate the call to a MessageBox.Show in an EXE I created. The only logic in my "TrialApp.exe" is: public partial class Form1 : Form { public Form1() { InitializeComponent(); } private void Form1_Load(object sender, EventArgs e) { MessageBox.Show("This is trial app"); } } Compiled on the Release configuration: http://rapidshare.com/files/392503054/TrialApp.exe.html What I do to locate the call Run the application in WinDBG and break after the message box appears. Get the CLR stack with !clrstack: 0040e840 5e21350b [InlinedCallFrame: 0040e840] System.Windows.Forms.SafeNativeMethods.MessageBox(System.Runtime.InteropServices.HandleRef, System.String, System.String, Int32) 0040e894 5e21350b System.Windows.Forms.MessageBox.ShowCore(System.Windows.Forms.IWin32Window, System.String, System.String, System.Windows.Forms.MessageBoxButtons, System.Windows.Forms.MessageBoxIcon, System.Windows.Forms.MessageBoxDefaultButton, System.Windows.Forms.MessageBoxOptions, Boolean) 0040e898 002701f0 [InlinedCallFrame: 0040e898] 0040e934 002701f0 TrialApp.Form1.Form1_Load(System.Object, System.EventArgs) Get the MethodDesc structure (using the address of Form1_Load) !ip2md 002701f0 MethodDesc: 001762f8 Method Name: TrialApp.Form1.Form1_Load(System.Object, System.EventArgs) Class: 00171678 MethodTable: 00176354 mdToken: 06000005 Module: 00172e9c IsJitted: yes CodeAddr: 002701d0 Transparency: Critical Source file: D:\temp\TrialApp\TrialApp\Form1.cs @ 22 Dump the IL of this method (by MethodDesc) !dumpil 001762f8 IL_0000: ldstr "This is trial app" IL_0005: call System.Windows.Forms.MessageBox::Show IL_000a: pop IL_000b: ret So, as the video mentioned, the call to to Show is 5 bytes from the beginning of the method implementation. Now I open CFFExplorer (just like in the video) and get the RVA of the Form1_Load method: 00002083. After this, I go to Address Converter (again in CFF Explorer) and navigate to offset 00002083. There we have: 32 72 01 00 00 70 28 16 00 00 0A 26 2A 7A 03 2C 13 02 7B 02 00 00 04 2C 0B 02 7B 02 00 00 04 6F 17 00 00 0A 02 03 28 18 00 00 0A 2A 00 03 30 04 00 67 00 00 00 00 00 00 00 02 28 19 00 00 0A 02 In the video is mentioned that the first 12 bytes are for the method header so I skip them 2A 7A 03 2C 13 02 7B 02 00 00 04 2C 0B 02 7B 02 00 00 04 6F 17 00 00 0A 02 03 28 18 00 00 0A 2A 00 03 30 04 00 67 00 00 00 00 00 00 00 02 28 19 00 00 0A 02 5 bytes from the beginning of the implementation should be the opcode for method call (28). Unfortunately, is not there. 02 7B 02 00 00 04 2C 0B 02 7B 02 00 00 04 6F 17 00 00 0A 02 03 28 18 00 00 0A 2A 00 03 30 04 00 67 00 00 00 00 00 00 00 02 28 19 00 00 0A 02 Questions: What am I doing wrong? Why there is no method call at that position in the file? Or maybe the video is missing some information... Why the guy in that video replaces the call with 9 zeros?

    Read the article

  • How do I create a shortcut to CMD.EXE that asks for elevation using INNO Setup?

    - by Maltrap
    Hi, using INNO Setup I currently have the following entry under the [ICONS] section: Name: "{group}\My App\My App - Command Prompt"; Filename: "cmd.exe"; WorkingDir: "{app}" This shortcut launches a command prompt straight into my application's folder. Unfortunately it isn't launched as elevated which means the commands the user runs from there doesn't have appropriate rights. Using INNO Setup, how can I create a shortcut to CMD.exe (in a specific folder) that requires elevation? Doing this for other applications can be done via a manifest file. My question is, how do I use it using INNO, and if I can't, what are my alternatives?

    Read the article

  • Is it possible to change a exe's icon without recompiling it?

    - by Microkernel
    Hi all, I have lot of executable that I have compiled (long time back) for many of which I don't have sourcecode now. But when I compiled them I didn't put any icons for them, so they all look like same dull, bald default icon. So my questions are, (1) is it possible for me to write a software that can change the resources section of the exe and change its looks? If so, can anyone plz point me to the location where its explained? (I am a beginner, I have no idea on the exe format and all) Also its fun to keep changing Icons without having the pain of recompiling everything just for the icon change... (2) This is raises a natural converse question, Is it similarly possible to zap out the icon used by some file and use it for some other file? (If so, plz point me to location where I can get some details. I am a C/C++ developers and I am looking for solution on Windows Platform... Regards, MicroKernel

    Read the article

  • Why does WMI Provider Host ( WmiPrvSE.exe ) keep spiking my CPU ?

    - by Sathya
    I generally keep my laptop on 24x7, and at the end of the day it's really annoying to have my thighs burnt because over overheating. The overheating seems to be a result of WMI Provider Host ( WmiPrvSE.exe ) spiking the CPU utilization to 25% every few minutes. Any ideas why this is happening ? I have an HP Envy 14 (w/ the HP bundled crap) running on Windows 7 Home Premium. (Note: Based on @nhinkle's past observations, it seems that HP Wireless Manager might be the culprit, is there any way to confirm this ?)

    Read the article

  • Can An Assembly Be Installed In The GAC but not Show Up In Gacutil.exe?

    - by Brett Bim
    I've got an application where some assemblies are copied to C:\Windows\assembly upon deployment under the assumption that this installs them in the GAC. The application seems to work but when I run gacutil.exe on the copied assemblies, it says the Global Assembly Cache contains 0 assemblies. Should all assemblies in c:\Windows\assembly show up in gacutil? If not, why not? How can I verify that the assembly is in fact installed in the GAC? I have always used gacutil.exe in the past to register assemblies so doing a file copy is new to me and I'm trying to understand the ramifications.

    Read the article

  • Is DevCon.exe still the best way to restart/power cycle USB ports after resuming from hibernation in

    - by ProfessionalAmateur
    I have a USB broadband card on my Windows 7 laptop. It loathes resuming from hibernation properly. Back in the XP days I would issue a call devcon.exe from the command prompt and restart the selected ports (Saves you having to manually unplug and plug back in your USB devices). Ive been trying this is Windows 7, but the UAC keeps getting in the way. I'll start a command prompt. Issue the devcon command, but UAC asks me if I really want to do this, when I click yes it opens a different command prompt and launches the command. After the command completed this new prompt window closes faster than the speed of light and I cannot see the results. So Im thinking there has to be a better way to do this in the Vista/Win7 world...?

    Read the article

< Previous Page | 33 34 35 36 37 38 39 40 41 42 43 44  | Next Page >