Search Results

Search found 1864 results on 75 pages for 'raid'.

Page 38/75 | < Previous Page | 34 35 36 37 38 39 40 41 42 43 44 45  | Next Page >

  • Scaling databases with cheap SSD hard drives

    - by Dennis Kashkin
    Hey guys! I hope that many of you are working with high traffic database-driven websites, and chances are that your main scalability issues are in the database. I noticed a couple of things lately: Most large databases require a team of DBAs in order to scale. They constantly struggle with limitations of hard drives and end up with very expensive solutions (SANs or large RAIDs, frequent maintenance windows for defragging and repartitioning, etc.) The actual annual cost of maintaining such databases is in $100K-$1M range which is too steep for me :) Finally, we got several companies like Intel, Samsung, FusionIO, etc. that just started selling extremely fast yet affordable SSD hard drives based on SLC Flash technology. These drives are 100 times faster in random read/writes than the best spinning hard drives on the market (up to 50,000 random writes per second). Their seek time is pretty much zero, so the cost of random I/O is the same as sequential I/O, which is awesome for databases. These SSD drives cost around $10-$20 per gigabyte, and they are relatively small (64GB). So, there seems to be an opportunity to avoid the HUGE costs of scaling databases the traditional way by simply building a big enough RAID 5 array of SSD drives (which would cost only a few thousand dollars). Then we don't care if the database file is fragmented, and we can afford 100 times more disk writes per second without having to spread the database across 100 spindles. . Is anybody else interested in this? I've been testing a few SSD drives and can share my results. If anybody on this site has already solved their I/O bottleneck with SSDs, I would love to hear your war stories! PS. I know that there are plenty of expensive solutions out there that help with scalability, for example the time proven RAM-based SANs. I want to be clear that even $50K is too expensive for my project. I have to find a solution that costs no more than $10K and does not take much time to implement.

    Read the article

  • Using udev to create a character device based on a driver being loaded

    - by SteveCB
    I'm in the process of setting up RAID monitoring for a number of Dell servers that use the PERC 6i integrated card. We're using Nagios at present and the check_megasasctl plugin seems to fit the bill. However, the plugin relies upon the existence of: /dev/megaraid_sas_ioctl_node This device node doesn't exist by default, you have to create it by hand using something like: mknod /dev/megaraid_sas_ioctl_node c 253 0 Now, to make the existence of this device node persistent across reboots, I thought I could write a udev rule, but as usual, I'm missing something. I thought I could create a file such as /etc/udev/rules.d/10-local/rules that contained: DRIVER=="megasas" NAME="megaraid_sas_ioctl_node" MODE="0600" But this doesn't work - no device node after a reboot. Dmesg output indicates the megasas driver is loaded and functional: megasas: 00.00.04.01-RH1 Thu July 10 09:41:51 PST 2008 megasas: 0x1000:0x0060:0x1028:0x1f0c: bus 1:slot 0:func 0 megasas: FW now in Ready state Further, I don't see any means to instruct udev on which type of device node to create: character or block. I suspect I'm failing to understand exactly how udev is meant to work. I realise I could just cheat and run MegaCLI in /etc/rc.local, redirecting output to /dev/null; it creates the megaraid_sas_ioctl_node device node as part of its execution. I just thought using udev rules would be a) cleaner and b) a useful learning exercise. Perhaps I should just dump the above mknod command in /etc/rc.local... So how do I get udev to create the /dev/megaraid_sas_ioctl_node device node based on the presence of the megasas driver? Cheers Steve

    Read the article

  • Flash Backed Write Cache (FBWC) without capacitor pack

    - by Martyn
    I brought a HP Smart Array P410 controller and it is installed and working fine in a HP Prolient Microserver with 4 drives in two RAID 1 arrays. I didn’t realise however that it came without any cache so would only work by directly writing straight to the disk, and the performance was horrible. So I then brought the 512MB Flash Backed Write Cache (FBWC) memory module as I was under the impression that with FBWC I would not need a battery. I got this idea from a forum post. "What do you guys think of the choice between 'BBWC' (battery backed write cache) and 'FBWC' (flash backed write cache)? The flashed based ones use non-volitile memory so need no battery." After installing the cache module however the server pretty much won’t boot. The P410 has a flashing amber light on it, and from the manual that doesn’t sound good. I’ve managed to get to the on board BIOS once and even managed to get to boot to the HP Array Configuration Utility (ACU) CD once, but every other time the Server continuingly reboots once it get to the POST screen and reads ARRAY INITILIZING %%%. The one time I reached the ACU, it reported a problem with the Cache Module. To me, it seems like the cache module is faulty, however the supplier tells me “Do you have an FBWC battery pack, p/n 587324-001, because that is required for the cache to work. If you have it, please complete an RMA form and we'll send a replacement / credit.” Does this sound right to you? I’ve been ordering the parts from the US and I don’t want to spend $77 + $40 p&p on a battery, wait a week for the shipping to find the card is faulty, and I don’t want to send back a working card?

    Read the article

  • Why database partitioning didn't work? Extract from thedailywtf.com

    - by questzen
    Original link. http://thedailywtf.com/Articles/The-Certified-DBA.aspx. Article summary: The DBA suggests an approach involving rigorous partitioning, 10 partitions per disk (3 actual disks and 3 raid). The stats show that the performance is non-optimal. Then the DBA suggests an alternative of 1 partition per disk (with more added disks). This also fails. The sys-admin then sets up a single disk, single partition and saves the day. The size of disks was not mentioned but given today,s typical disk sizes (of the order of 100 GB), the partitions ; would be huge, it surprises me that a single disk with all partitions outperformed. Initially I suspect that the data was segregated and hence faster reads. But how come the performance didn't degrade as time went by with all the inserts and updates happening? Saw this on reddit, but the explanation was by far spindle/platter centered. There was no mention in the article about this. Is there any other reason? I can only guess that the tables were using a incorrect hash distribution causing non-uniform allocation across disks (wrong partitioning); this would increase fetch times. Any thoughts?

    Read the article

  • Would an array of SSD drives be able to succesfully substitute the system memory?

    - by Florin Mircea
    I watched a few videos trying to answer this. This video (youtube.com/watch?v=eULFf6F5Ri8) shows a bunch of guys stacking 24 SSD's reaching a peak of around 2GBps r/w. That's under the limit of the worst DDR3 in this list (memorybenchmark.net/write_ddr3_amd.html) - that shows DDR3 memory performance varying from 2.78 to 6.55 Gb per second, but that video is over 3 years old. This video (youtube.com/watch?v=27GmBzQWwP0) shows a more optimistic situation, but for PCI-E SSD drives: 5 drives peaking at around 4Gb. And this other video shows that stacking up more than 3 SSD's doesn't realistically offer a substantial added performance. This and the fact that in all benchmarks the drives act quite poorly when dealing with small files (5k file read/write averaging from 10MB to around 30-40MBps) as opposed to how native memory handles such files, seems to indicate a definite NO to this question. Also, the write life cycle is indeed limited and the drives might wear out quickly, as kindly pointed out by paddy. However, I wanted to get more opinions on this. Would it be possible to at least obtain current memory performance with SSD's in RAID 0? And if so, in what circumstances? I am assuming using this configuration with a Windows OS that has a memory pagefile resident to that stack of SSD's, thus making it very fast to work with.

    Read the article

  • Can a non-redundant RAID5 cause any serious problems (compared to RAID0)?

    - by leemes
    I used to have a three-disc RAID5 (mdadm) in my computer for personal media storage (music, videos, photos, programs, games, ...). It had three discs with 750 GB each, resulting in an array capacity of 1.5 TB. One day (one year ago), I needed one of those discs to install another operating system. I thought, I don't need the redundancy anymore since I backup the most important stuff (personal photos e.g.) on an external disc anyway. So I decided to remove one of the three discs without converting the RAID to RAID0 or even two separate discs, because I had no temporary storage (since one cannot simply convert the RAID5 to RAID0 AFAIK). So now, for about one year, I have a non-redundant RAID5 with 2 of 3 discs running. Sometimes, one of the discs has a defective contact at the power cable or something similar causing the drive to stop working temporarily (I don't know exactly what it is). Since it still works when rebooting the computer and in most cases by calling some mdadm commands, it wasn't that problematic. Note that the data is not very critical, since I still have a backup of the most important stuff. But in the last few weeks, one of the drives fails very frequently (every few hours), so it gets really annoying to manage this. My questions are: Is there any disadvantage (apart from the annoying management) of a non-redundant RAID5 (with one drive less than typical) over a RAID0? If I understand it correctly, both have no redundancy and the same capacity. On a temporary drive failure, I can restart the array in both cases, assuming that the drive itself still works after the failure. Can it happen that the drive contents alter on a drive failure, making the array inconsistent? If so, can I tell mdadm to check the array for failures (without a file system level checking tool)? Since the drive most probably only has a defective contact causing it to fail for a second only, can I tell mdadm to automatically restart the array, so I will not even notice the failure if no application wanted to access the file system during the failure?

    Read the article

  • file read performance degrades as number of files increases

    - by bfallik-bamboom
    We're observing poor file read IO results that we'd like to better understand. We can use fio to write 100 files with a sustained aggregate throughput of ~700MB/s. When we switch the test to read instead of write, the aggregate throughput is only ~55MB/s. The drop seems related to the number of files since the throughput for read and write are comparable for a single file then diverge proportionally as we increase the number of files. The test server has 24 CPU cores, 48GB of memory, and is running CentOS 6.0. The disk hardware is a RAID 6 array with 12 disks and a Dell H800 controller. This device is partitioned with ext4 using the default settings. Increasing the readahead (using blockdev) improves the read throughput significantly but it still doesn't match write speed. For instance, increasing the readahead from 128KB to 1M improved the read throughput to ~145MB/s. Is this a known performance issue in our OS/disk/filesystem configuration? If so, how can we tell? If not, what tools or tests can we use to further isolate the issue? Thanks.

    Read the article

  • WD1000FYPS harddrive is marked 0 mb in 3ware (and no SMART)

    - by osgx
    After reboot my SATA 1TB WD1000FYPS (previously is was "Drive error") is marked 0 mb in 3ware web gui. Complete message: Available Drives (Controller ID 0) Port 1 WDC WD1000FYPS-01ZKB0 0.00 MB NOT SUPPORTED [Remove Drive] SMART gives me only Device Model and ATA protocol version 1 (not 7-8 as it must be for SATA) What does it mean? Just before reboot, when is was marked only with "Device Error", smart was: Device Model: WDC WD1000FYPS-01ZKB0 Serial Number: WD-WCASJ1130*** Firmware Version: 02.01B01 User Capacity: 1,000,204,886,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Sun Mar 7 18:47:35 2010 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled SMART overall-health self-assessment test result: PASSED SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0003 188 186 021 Pre-fail Always - 7591 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 229 5 Reallocated_Sector_Ct 0x0033 199 199 140 Pre-fail Always - 3 7 Seek_Error_Rate 0x000e 193 193 000 Old_age Always - 125 9 Power_On_Hours 0x0032 078 078 000 Old_age Always - 16615 10 Spin_Retry_Count 0x0012 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0012 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 77 192 Power-Off_Retract_Count 0x0032 198 198 000 Old_age Always - 1564 193 Load_Cycle_Count 0x0032 146 146 000 Old_age Always - 164824 194 Temperature_Celsius 0x0022 117 100 000 Old_age Always - 35 196 Reallocated_Event_Count 0x0032 199 199 000 Old_age Always - 1 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0 What can be wrong with he? Can it be restored? PS new smart is === START OF INFORMATION SECTION === Device Model: WDC WD1000FYPS-01ZKB0 Serial Number: [No Information Found] Firmware Version: [No Information Found] Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 1 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Mon Mar 8 00:29:44 2010 MSK SMART is only available in ATA Version 3 Revision 3 or greater. We will try to proceed in spite of this. SMART support is: Ambiguous - ATA IDENTIFY DEVICE words 82-83 don't show if SMART supported. Checking for SMART support by trying SMART ENABLE command. Command failed, ata.status=(0x00), ata.command=(0x51), ata.flags=(0x01) Error SMART Enable failed: Input/output error SMART ENABLE failed - this establishes that this device lacks SMART functionality. A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options. PPS There was a rapid grow of " 192 Power-Off_Retract_Count " before dying. The hard was used in raid, with several hards from the same fabric packaging box (close id's). The hard drives were placed identically. Rapid means almost linear grow from 300 to 1700 in 6-7 hours. Maximal temperature was 41C. (thanks to munin's smart monitoring)

    Read the article

  • Why is domU faster than dom0 on IO?

    - by Paco
    I have installed debian 7 on a physical machine. This is the configuration of the machine: 3 hard drives using RAID 5 Strip element size: 1M Read policy: Adaptive read ahead Write policy: Write Through /boot 200 MB ext2 / 15 GB ext3 SWAP 10GB LVM rest (~500GB) emphasized text I installed postgresql, created a big database (over 1GB). I have an SQL request that takes a lot of time to run (a SELECT statement, so it only reads data from the database). This request takes approximately 5.5 seconds to run. Then, I installed XEN, created a domU, with another debian distro. On this OS, I also installed postgresql, with the same database. The same SQL request takes only 2.5 seconds to run. I checked the kernel on both dom0 and domU. uname-a returns "Linux debian 3.2.0-4-amd64 #1 SMP Debian 3.2.41-2+deb7u2 x86_64 GNU/Linux" on both systems. I checked the kernel parameters, which are approximately the same. For those that are relevant, I changed their values to make them match on both systems using sysctl. I saw no changes (the requests still take the same amount of time). After this, I checked the file systems. I used ext3 on domU. Still no changes. I installed hdparm, and ran hdparm -Tt on both systems, on all my partitions on both systems, and I get similar results. Now, I am stuck, I don't know what is different, and what could be the cause of such a big difference. Additional Info: Debian runs on a Dell server PowerEdge 2950 postgresql: 9.1.9 (both dom0 and domU) xen-linux-system: 3.2.0 xen-hypervisor: 4.1 Thanks EDIT: As Krzysztof Ksiezyk suggested, it might be due to some file caching system. I ran the dd command to test both the read and write speed. Here is domU: root@test1:~# dd if=/dev/zero of=/root/dd count=5MB bs=1MB ^C2020+0 records in 2020+0 records out 2020000000 bytes (2.0 GB) copied, 18.8289 s, 107 MB/s root@test1:~# dd if=/root/dd of=/dev/null count=5MB bs=1MB 2020+0 records in 2020+0 records out 2020000000 bytes (2.0 GB) copied, 15.0549 s, 134 MB/s And here is dom0: root@debian:~# dd if=/dev/zero of=/root/dd count=5MB bs=1MB ^C1693+0 records in 1693+0 records out 1693000000 bytes (1.7 GB) copied, 8.87281 s, 191 MB/s root@debian:~# dd if=/root/dd of=/dev/null count=5MB bs=1MB 1693+0 records in 1693+0 records out 1693000000 bytes (1.7 GB) copied, 0.501509 s, 3.4 GB/s What can be the cause of this caching system? And how can we "fix" it? Can we apply it to dom0? EDIT 2: I switched my virtual disk type. To do so I followed this article. I did a dd if=/dev/vg0/test1-disk of=/mnt/test1-disk.img bs=16M Then in /etc/xen/test1.cfg, I changed the disk parameter to use file: instead of phy: it should have removed the file caching, but I still get the same numbers (domU being much faster for Postgres)

    Read the article

  • Have a server, need to figure out a method of backup

    - by PolishHurricane
    My company has an older Dell 2650 server running ArchLinux x64: http://www.dell.com/downloads/global/products/pedge/en/2650_specs.pdf (2 x 2.4GHz Intel Xeon w/around 3287 RAM according to "free -m") We use it to host our internal company site and to post some information from our orders to and we'd like the ability to keep it up as much as possible. What we require: - It needs to always be functional from 8am to 4pm for our data entry person to use it and others to do other things required on it. - If it goes down, we need a quick way to get the machine running again. - If it goes down, we would like to have the data backed up. Some of the major problems include: - The servers old and it may have memory issues - We don't know when one of the hard drives could fail - Our power goes out here once in a while We have a battery backup, but that's pretty much it and it's not for long term. If the server does go down, we have another system in place to store order information that comes in while it's down and repost it when it's back, but we need it up during the day. So we're wondering, what should we get for options? These are the things we thought of, sort of: Setup RAID 1, but that would involve wiping everything right? If we do that, how would we transfer the data over without messing up the server? We could buy an extra server or 2 off eBay for $100, the same model, is that practical or should we get something else? Should we buy a PC or another better server and host off that because it is if anything easier to exchange parts? Should we keep extra parts handy incase it implodes? Should we buy/use backup software? We hear drobo's are cool, but suck. Perhaps there is a software solution to this problem that backs up to another machine or gets us up and running again quickly. Also, if we are to purchase hardware, what is decent? Does anybody know of one for ArchLinux/Linux? We both know a ton about computers but we're kind of unsure what step to take with this, especially with this type of server. Thanks

    Read the article

  • Do I need to be worried about these SMART drive temperatures?

    - by Steve Lorimer
    I have 5 hard drives in a machine sitting in a cupboard. /dev/sda is a 500GB Seagate drive, and is the boot disk. /dev/sd{b,c,d,e} are 2TB drives in a raid6 configuration. smartctl is showing significantly higher temperatures (like ~140 degrees celsius) on the raid drives than the boot drive. Do I need to be worried? /dev/sdb and /dev/sde are new Western Digital Black drives (new=1 week) /dev/sdc and /dev/sdd are 5 year old Hitachi drives /dev/sda [SAT], Temperature_Celsius changed from 40 to 39 /dev/sdc [SAT], Temperature_Celsius changed from 142 to 146 /dev/sdc [SAT], Temperature_Celsius changed from 146 to 142 /dev/sdd [SAT], Temperature_Celsius changed from 142 to 146 /dev/sda [SAT], Airflow_Temperature_Cel changed from 61 to 62 /dev/sda [SAT], Temperature_Celsius changed from 39 to 38 /dev/sde [SAT], Temperature_Celsius changed from 107 to 108 /dev/sdb [SAT], Temperature_Celsius changed from 108 to 109 /dev/sdc [SAT], Temperature_Celsius changed from 146 to 150 /dev/sdc [SAT], Temperature_Celsius changed from 146 to 150 /dev/sda [SAT], Airflow_Temperature_Cel changed from 62 to 61 /dev/sda [SAT], Temperature_Celsius changed from 38 to 39 Update: Adding detailed drive information as per request: /dev/sda =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Pipeline HD 5900.2 Device Model: ST3500312CS Serial Number: 5VV47HXA LU WWN Device Id: 5 000c50 02aad5ad6 Firmware Version: SC13 User Capacity: 500,107,862,016 bytes [500 GB] Sector Size: 512 bytes logical/physical Rotation Rate: 5900 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 1.5 Gb/s (current: 1.5 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled /dev/sdb =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WDC WD2003FZEX-00Z4SA0 Serial Number: WD-WMC1F1398726 LU WWN Device Id: 5 0014ee 003b8bd25 Firmware Version: 01.01A01 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled /dev/sdc =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Deskstar 7K3000 Device Model: Hitachi HDS723020BLA642 Serial Number: MN1220F30WSTUD LU WWN Device Id: 5 000cca 369cc9f5d Firmware Version: MN6OA580 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled /dev/sdd =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Deskstar 7K3000 Device Model: Hitachi HDS723020BLA642 Serial Number: MN1220F30WST4D LU WWN Device Id: 5 000cca 369cc9f48 Firmware Version: MN6OA580 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 1.5 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled /dev/sde =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WDC WD2003FZEX-00Z4SA0 Serial Number: WD-WMC1F1483782 LU WWN Device Id: 5 0014ee 3002d235c Firmware Version: 01.01A01 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 1.5 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled

    Read the article

  • fd partitions gone from 2 discs, md happy with it and resyncs. How to recover ?

    - by d0nd
    Hey gurus, need some help badly with this one. I run a server with a 6Tb md raid5 volume built over 7*1Tb disks. I've had to shut down the server lately and when it went back up, 2 out of the 7 disks used for the raid volume had lost its conf : dmesg : [ 10.184167] sda: sda1 sda2 sda3 // System disk [ 10.202072] sdb: sdb1 [ 10.210073] sdc: sdc1 [ 10.222073] sdd: sdd1 [ 10.229330] sde: sde1 [ 10.239449] sdf: sdf1 [ 11.099896] sdg: unknown partition table [ 11.255641] sdh: unknown partition table All 7 disks have same geometry and were configured alike : dmesg : Disk /dev/sdb: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x1e7481a5 Device Boot Start End Blocks Id System /dev/sdb1 1 121601 976760001 fd Linux raid autodetect All 7 disks (sdb1, sdc1, sdd1, sde1, sdf1, sdg1, sdh1) were used in a md raid5 xfs volume. When booting, md, which was (obviously) out of sync kicked in and automatically started rebuilding over the 7 disks, including the two "faulty" ones; xfs tried to do some shenanigans as well: dmesg : [ 19.566941] md: md0 stopped. [ 19.817038] md: bind<sdc1> [ 19.817339] md: bind<sdd1> [ 19.817465] md: bind<sde1> [ 19.817739] md: bind<sdf1> [ 19.817917] md: bind<sdh> [ 19.818079] md: bind<sdg> [ 19.818198] md: bind<sdb1> [ 19.818248] md: md0: raid array is not clean -- starting background reconstruction [ 19.825259] raid5: device sdb1 operational as raid disk 0 [ 19.825261] raid5: device sdg operational as raid disk 6 [ 19.825262] raid5: device sdh operational as raid disk 5 [ 19.825264] raid5: device sdf1 operational as raid disk 4 [ 19.825265] raid5: device sde1 operational as raid disk 3 [ 19.825267] raid5: device sdd1 operational as raid disk 2 [ 19.825268] raid5: device sdc1 operational as raid disk 1 [ 19.825665] raid5: allocated 7334kB for md0 [ 19.825667] raid5: raid level 5 set md0 active with 7 out of 7 devices, algorithm 2 [ 19.825669] RAID5 conf printout: [ 19.825670] --- rd:7 wd:7 [ 19.825671] disk 0, o:1, dev:sdb1 [ 19.825672] disk 1, o:1, dev:sdc1 [ 19.825673] disk 2, o:1, dev:sdd1 [ 19.825675] disk 3, o:1, dev:sde1 [ 19.825676] disk 4, o:1, dev:sdf1 [ 19.825677] disk 5, o:1, dev:sdh [ 19.825679] disk 6, o:1, dev:sdg [ 19.899787] PM: Starting manual resume from disk [ 28.663228] Filesystem "md0": Disabling barriers, not supported by the underlying device [ 28.663228] XFS mounting filesystem md0 [ 28.884433] md: resync of RAID array md0 [ 28.884433] md: minimum _guaranteed_ speed: 1000 KB/sec/disk. [ 28.884433] md: using maximum available idle IO bandwidth (but not more than 200000 KB/sec) for resync. [ 28.884433] md: using 128k window, over a total of 976759936 blocks. [ 29.025980] Starting XFS recovery on filesystem: md0 (logdev: internal) [ 32.680486] XFS: xlog_recover_process_data: bad clientid [ 32.680495] XFS: log mount/recovery failed: error 5 [ 32.682773] XFS: log mount failed I ran fdisk and flagged sdg1 and sdh1 as fd. I tried to reassemble the array but it didnt work: no matter what was in mdadm.conf, it still uses sdg and sdh instead of sdg1 and sdh1. I checked in /dev and I see no sdg1 and and sdh1, shich explains why it wont use it. I just don't know why those partitions are gone from /dev and how to readd those... blkid : /dev/sda1: LABEL="boot" UUID="519790ae-32fe-4c15-a7f6-f1bea8139409" TYPE="ext2" /dev/sda2: TYPE="swap" /dev/sda3: LABEL="root" UUID="91390d23-ed31-4af0-917e-e599457f6155" TYPE="ext3" /dev/sdb1: UUID="2802e68a-dd11-c519-e8af-0d8f4ed72889" TYPE="mdraid" /dev/sdc1: UUID="2802e68a-dd11-c519-e8af-0d8f4ed72889" TYPE="mdraid" /dev/sdd1: UUID="2802e68a-dd11-c519-e8af-0d8f4ed72889" TYPE="mdraid" /dev/sde1: UUID="2802e68a-dd11-c519-e8af-0d8f4ed72889" TYPE="mdraid" /dev/sdf1: UUID="2802e68a-dd11-c519-e8af-0d8f4ed72889" TYPE="mdraid" /dev/sdg: UUID="2802e68a-dd11-c519-e8af-0d8f4ed72889" TYPE="mdraid" /dev/sdh: UUID="2802e68a-dd11-c519-e8af-0d8f4ed72889" TYPE="mdraid" fdisk -l : Disk /dev/sda: 40.0 GB, 40020664320 bytes 255 heads, 63 sectors/track, 4865 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x8c878c87 Device Boot Start End Blocks Id System /dev/sda1 * 1 12 96358+ 83 Linux /dev/sda2 13 134 979965 82 Linux swap / Solaris /dev/sda3 135 4865 38001757+ 83 Linux Disk /dev/sdb: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x1e7481a5 Device Boot Start End Blocks Id System /dev/sdb1 1 121601 976760001 fd Linux raid autodetect Disk /dev/sdc: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xc9bdc1e9 Device Boot Start End Blocks Id System /dev/sdc1 1 121601 976760001 fd Linux raid autodetect Disk /dev/sdd: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xcc356c30 Device Boot Start End Blocks Id System /dev/sdd1 1 121601 976760001 fd Linux raid autodetect Disk /dev/sde: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xe87f7a3d Device Boot Start End Blocks Id System /dev/sde1 1 121601 976760001 fd Linux raid autodetect Disk /dev/sdf: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xb17a2d22 Device Boot Start End Blocks Id System /dev/sdf1 1 121601 976760001 fd Linux raid autodetect Disk /dev/sdg: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x8f3bce61 Device Boot Start End Blocks Id System /dev/sdg1 1 121601 976760001 fd Linux raid autodetect Disk /dev/sdh: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xa98062ce Device Boot Start End Blocks Id System /dev/sdh1 1 121601 976760001 fd Linux raid autodetect I really dont know what happened nor how to recover from this mess. Needless to say the 5TB or so worth of data sitting on those disks are very valuable to me... Any idea any one? Did anybody ever experienced a similar situation or know how to recover from it ? Can someone help me? I'm really desperate... :x

    Read the article

  • 2-Bay External HDD Enclosure in JBOD mode fails to detect both drives (Linux & Windows)

    - by mgc8888
    I recently purchased a couple of USB 3.0 External HDD Enclosures to use for storage and backup; the idea was to have one act as backup to the other, with 4 x 3TB drives in total. However, the second drive in each is not accessible in either Linux nor Windows, and I could not determine the reason. 1. Situation The two enclosures are slightly different (couldn't find them in stock at the same time) yet from many little details appear to be the same Chinese base design with a tweaked outer shell. The models are: Sharkoon 2-Bay RAID Box Fantec MR-35DU3 The drives are Seagate 3TB Barracuda ST33000651AS, firmware CC44, all identical. From reading manuals and online sources, I determined that JBOD would be the optimal setup for my needs -- addressing the two drives separately in each enclosure would be important, making it easy to swap drives and mix&match them if needed; all the other modes implied the controller doing a combination of the drives. The software used was Debian GNU/Linux - testing/wheezy - kernel 2.6.39-2 and Windows 7 Ultimate. 2. Description of the problem Now, here comes the problem: every time I connect either of the enclosures to a PC using the supplied cable (tried a different one as well), only the HDD in the top bay is readable, the one below is detected yet errors out in various ways. According to the manuals, it should not happen: in JBOD, the system should be able to "see" two separate drives upon connection. This happens with both enclosures and any combination of HDDs (i.e. if I swap them, the same thing happens), so the HDDs are good and I think so are the enclosures (two different companies making similar products that failed in an identical fashion would be very unlikely). The top HDD can be used fine every time, I actually tried a speed test from Linux and got about 150MiB/s reads, so all is working as it should; the one below refuses to work every time. So the failure is consistent. To make sure this was not some obscure Linux bug, I tried the same under Windows 7, and the system also only created one drive letter for a drive of 3TB size (so it was only seeing one instead of both). Placing an older, known good, 2TB drive in the top bay made that the one recognised, so we have the same issue under Windows as well. Log entries under Linux (tested here with a 3TB and a 2TB drive so I could differentiate them; either one works in the top enclosure, in the test setup the 3TB one is on top). You can see them being detected, the top one is ok, but for the bottom one only errors: Jul 19 23:28:15 media kernel: [260150.582436] usb 6-1: New USB device found, idVendor=1ca1, idProduct=18ae Jul 19 23:28:15 media kernel: [260150.582440] usb 6-1: New USB device strings: Mfr=1, Product=2, SerialNumber=3 Jul 19 23:28:15 media kernel: [260150.582442] usb 6-1: Product: Usb Sata Bridge Jul 19 23:28:15 media kernel: [260150.582444] usb 6-1: Manufacturer: SYMWAVE Jul 19 23:28:15 media kernel: [260150.582446] usb 6-1: SerialNumber: 39584B304C4E3441 Jul 19 23:28:15 media kernel: [260150.870412] scsi11 : usb-storage 6-1:1.0 Jul 19 23:28:16 media kernel: [260151.882087] scsi 11:0:0:0: Direct-Access SYMWAVE ST33000651AS CC44 PQ: 0 ANSI: 4 Jul 19 23:28:16 media kernel: [260151.882242] scsi 11:0:0:1: Direct-Access SYMWAVE ST32000641AS CC12 PQ: 0 ANSI: 4 Jul 19 23:28:16 media kernel: [260151.882677] sd 11:0:0:0: Attached scsi generic sg2 type 0 Jul 19 23:28:16 media kernel: [260151.882774] sd 11:0:0:0: [sdb] Very big device. Trying to use READ CAPACITY(16). Jul 19 23:28:16 media kernel: [260151.882857] sd 11:0:0:1: Attached scsi generic sg3 type 0 Jul 19 23:28:16 media kernel: [260151.882893] sd 11:0:0:0: [sdb] 5860533168 512-byte logical blocks: (3.00 TB/2.72 TiB) Jul 19 23:28:16 media kernel: [260151.883085] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.883582] sd 11:0:0:0: [sdb] Write Protect is off Jul 19 23:28:16 media kernel: [260151.883961] sd 11:0:0:1: [sdc] 3907029168 512-byte logical blocks: (2.00 TB/1.81 TiB) Jul 19 23:28:16 media kernel: [260151.884145] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.884570] sd 11:0:0:1: [sdc] Write Protect is off Jul 19 23:28:16 media kernel: [260151.884855] sd 11:0:0:0: [sdb] Very big device. Trying to use READ CAPACITY(16). Jul 19 23:28:16 media kernel: [260151.885286] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.885807] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.909595] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.910159] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.910163] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.910167] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.910169] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.910172] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.910182] quiet_error: 2 callbacks suppressed Jul 19 23:28:16 media kernel: [260151.910570] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.911153] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.911156] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.911159] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.911161] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.911164] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.911385] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.911902] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.911905] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.911908] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.911910] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.911913] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.912128] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.912650] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.912653] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.912656] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.912657] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.912660] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.912876] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.913439] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.913442] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.913445] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.913446] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.913449] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.945227] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.945863] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.945866] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.945870] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.945871] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.945875] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 (...) and so on for like 10 seconds until it gives up (...) 3. Question So, my question would be: what is causing this? Am I missing something, should I configure things differently, is this a known limitation? Searching online for more information did not yield any useful results... Thank you in advance for any help!

    Read the article

  • Server 2008 RAID5 resynching

    - by benpage
    I built a W2K8 R2 server last weekend, and built a R5 array using Disk Management, 5x 1TB drives. For the next 60 hours the status said 'Resynching (X%)' as it built the array. during this time i did read and write to the drive (slowly) and once the rebuild was complete speeds were quite fast. I was copying over some data from a USB hard drive overnight, and the machine crashed (looking in the error i believe it was the driver for the usb drive) and so the RAID5 went back to resynching, since the machine was not shut down properly. The issue is, it's been about 48 hours since that started and I'm happy to say it will take roughly 60 hours again to resynch, however.. all this time in Disk Management, the status has only said 'Resynching', not 'Resynching (X%)'. The hard drive light is going nuts, and read/writes are slow again, so I'm assuming it is actually resynching. The question is - is that a correct assumption? and why is disk management not telling me what %age it's done? Is this normal behaviour for a not-properly-shut-down r5 array?

    Read the article

  • HP SmartArray P400 has slow read and write speed

    - by Tadas D.
    I have desktop in which I installed HP SmartArray P400 controller with two HP DF0146B8052 hard drives. I made RAID0 logical volume from them, but I am getting 20MB/s write speed and ~140-120MB/s read speed. Also there is quite low scatter for benchmark results (I am getting quite nice line) and it looks like controller is "capping" my speeds. I tried reseting controllers configuration and I haven't found any settings in HP ACU (Array Configuration Utility) to help me. I am using Windows 7 Ultimate and M4A78 board Does anyone have ideas what could be wrong? Also I am attaching diagnostic results.

    Read the article

  • Backup NAS to another NAS?

    - by Tronic
    hey there, is there a way to backup / transfer a NAS (it's like a big harddrive with some access to a webinterface, but closed linux etc.... only two ethernet ports) to another one? or is the only way to connect both NASs to my computer and copy the data from one to the other? it's like 750gb of data... thanks in advance... regards

    Read the article

  • Hard drive device names are different from one reboot to another in Ubuntu.

    - by Mike
    I have an Ubuntu machine (10.04 but had the same problem in 8.04) with a bunch of drives that I use as a file server. 1 SATA that I boot off of. 2 IDE that in RAID1 and 2 SATA in RAID1. The problem is the drives that I have in RAID1 change device names on reboot. This is a problem because the in my mdadm.conf a reference to /dev/sda1, for example, might not work the next time I reboot because /dev/sda1 could be a disk from another array. Any help getting around this would be appreciated. -Mike

    Read the article

  • Hard drive device names are different from one reboot to another in Ubuntu.

    - by Mike
    I have an Ubuntu machine (10.04 but had the same problem in 8.04) with a bunch of drives that I use as a file server. 1 SATA that I boot off of. 2 IDE that in RAID1 and 2 SATA in RAID1. The problem is the drives that I have in RAID1 change device names on reboot. This is a problem because the in my mdadm.conf a reference to /dev/sda1, for example, might not work the next time I reboot because /dev/sda1 could be a disk from another array. Any help getting around this would be appreciated. -Mike

    Read the article

  • How to understand the LSI HBA connector specs?

    - by Sandra
    When reading the specifications for the LSi SAS 9206-16e HBA, it says Storage Connectivity; Data Transfer Rates * 16 ports; 6Gb/s SAS 2.1 compliant SAS Bandwidth * Half Duplex 2400MB/s, x4, 6Gb/s SAS lanes Port Configurations * 16 ea, x1 ports (individual drives) * 4 ea, x4 wide ports * 2ea, x8 wide ports Connectors * Four (x4) mini-SAS HD external connectors (SFF8644) So there are 4 physical connectors. Question What is the bandwidth for each of the connectors? I would be temped to say 6Gb/s * 4, but then it mentions the "Port Configurations" and 2ea, 4ea, 16ea, which I don't understand what is. Does this mean, that the 4 physical connectors are not identical?

    Read the article

  • Event Log: atapi - the device did not respond within the timeout period - Freeze

    - by rjlopes
    Hi, I have a Windows Server 2003 that stops working randomly (displays image on monitor but is completely frozen), all I could found on the event log as causes were an error from atapi and a warning from msas2k3. The event log entries are: Event Type: Error Event Source: atapi Event Category: None Event ID: 9 Date: 22-07-2009 Time: 16:13:33 User: N/A Computer: SERVER Description: The device, \Device\Ide\IdePort0, did not respond within the timeout period. For more information, see Help and Support Center at http : // go.microsoft.com / fwlink / events.asp. Data: 0000: 0f 00 10 00 01 00 64 00 ......d. 0008: 00 00 00 00 09 00 04 c0 .......À 0010: 01 01 00 50 00 00 00 00 ...P.... 0018: f8 06 20 00 00 00 00 00 ø. ..... 0020: 00 00 00 00 00 00 00 00 ........ 0028: 00 00 00 00 01 00 00 00 ........ 0030: 00 00 00 00 07 00 00 00 ........ Event Type: Warning Event Source: msas2k3 Event Category: None Event ID: 129 Date: 22-07-2009 Time: 16:14:23 User: N/A Computer: SERVER Description: Reset to device, \Device\RaidPort0, was issued. For more information, see Help and Support Center at http : // go.microsoft.com / fwlink / events.asp. Data: 0000: 0f 00 10 00 01 00 68 00 ......h. 0008: 00 00 00 00 81 00 04 80 ......? 0010: 04 00 00 00 00 00 00 00 ........ 0018: 00 00 00 00 00 00 00 00 ........ 0020: 00 00 00 00 00 00 00 00 ........ 0028: 00 00 00 00 00 00 00 00 ........ 0030: 01 00 00 00 81 00 04 80 ......? Any hints?

    Read the article

  • KVM guest io is much slower than host io: is that normal?

    - by Evolver
    I have a Qemu-KVM host system setup on CentOS 6.3. Four 1TB SATA HDDs working in Software RAID10. Guest CentOS 6.3 is installed on separate LVM. People say that they see guest performance almost equal to host performance, but I don't see that. My i/o tests are showing 30-70% slower performance on guest than on host system. I tried to change scheduler (set elevator=deadline on host and elevator=noop on guest), set blkio.weight to 1000 in cgroup, change io to virtio... But none of these changes gave me any significant results. This is a guest .xml config part: <disk type='file' device='disk'> <driver name='qemu' type='raw'/> <source file='/dev/vgkvmnode/lv2'/> <target dev='vda' bus='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x05' function='0x0'/> </disk> There are my tests: Host system: iozone test # iozone -a -i0 -i1 -i2 -s8G -r64k random random KB reclen write rewrite read reread read write 8388608 64 189930 197436 266786 267254 28644 66642 dd read test: one process and then four simultaneous processes # dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct 1073741824 bytes (1.1 GB) copied, 4.23044 s, 254 MB/s # dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct skip=1024 & dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct skip=2048 & dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct skip=3072 & dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct skip=4096 1073741824 bytes (1.1 GB) copied, 14.4528 s, 74.3 MB/s 1073741824 bytes (1.1 GB) copied, 14.562 s, 73.7 MB/s 1073741824 bytes (1.1 GB) copied, 14.6341 s, 73.4 MB/s 1073741824 bytes (1.1 GB) copied, 14.7006 s, 73.0 MB/s dd write test: one process and then four simultaneous processes # dd if=/dev/zero of=test bs=1M count=1024 oflag=direct 1073741824 bytes (1.1 GB) copied, 6.2039 s, 173 MB/s # dd if=/dev/zero of=test bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test2 bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test3 bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test4 bs=1M count=1024 oflag=direct 1073741824 bytes (1.1 GB) copied, 32.7173 s, 32.8 MB/s 1073741824 bytes (1.1 GB) copied, 32.8868 s, 32.6 MB/s 1073741824 bytes (1.1 GB) copied, 32.9097 s, 32.6 MB/s 1073741824 bytes (1.1 GB) copied, 32.9688 s, 32.6 MB/s Guest system: iozone test # iozone -a -i0 -i1 -i2 -s512M -r64k random random KB reclen write rewrite read reread read write 524288 64 93374 154596 141193 149865 21394 46264 dd read test: one process and then four simultaneous processes # dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=1024 1073741824 bytes (1.1 GB) copied, 5.04356 s, 213 MB/s # dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=1024 & dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=2048 & dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=3072 & dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=4096 1073741824 bytes (1.1 GB) copied, 24.7348 s, 43.4 MB/s 1073741824 bytes (1.1 GB) copied, 24.7378 s, 43.4 MB/s 1073741824 bytes (1.1 GB) copied, 24.7408 s, 43.4 MB/s 1073741824 bytes (1.1 GB) copied, 24.744 s, 43.4 MB/s dd write test: one process and then four simultaneous processes # dd if=/dev/zero of=test bs=1M count=1024 oflag=direct 1073741824 bytes (1.1 GB) copied, 10.415 s, 103 MB/s # dd if=/dev/zero of=test bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test2 bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test3 bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test4 bs=1M count=1024 oflag=direct 1073741824 bytes (1.1 GB) copied, 49.8874 s, 21.5 MB/s 1073741824 bytes (1.1 GB) copied, 49.8608 s, 21.5 MB/s 1073741824 bytes (1.1 GB) copied, 49.8693 s, 21.5 MB/s 1073741824 bytes (1.1 GB) copied, 49.9427 s, 21.5 MB/s I wonder is that normal situation or did I missed something?

    Read the article

  • Migrating RAID6 array from HP SmartArray P600 to LSI MegaRAID SAS 8888ELP

    - by MLu
    My customer has an external RAID6 array (8x 1TB in HP MSA60 enclosure) attached to HP SmartArray P600 controller. They have now decided to replace the server and the new one comes with LSI MegaRAID SAS 8888ELP. The HW supplier insists the migration is as simple as pulling the eSATA cable from P600 and inserting it into LSI but I'm not convinced. Unfortunately I have nowhere to test, and will have to do the exercise on the production array :( So the question in brief - is it possible to import the HP SmartArray P600-created RAID6 array to LSI MegaRAID 8888ELP?

    Read the article

  • HP ML115 with P400 Smart Array Controller

    - by John
    Hi, I have a HP ML115 server I have installed a HP P400 Smart Array Controller card, I also have 4 x 1TB Samsung Hard drives. I'm unable to get the the controller to detect the hard drives, I have changed the drives to SATA 1.5G without luck, I have also tried connecting a single 80GB Maxtor drive without luck The controller shows up just after boot and tries to initialize, The controller does not show up in the POST prompt, although I can see the controller when booting off a ACU CD THe controller firmware is a little old v4.12 but I have no way to update it. Any ideas on how I can get this going?

    Read the article