Search Results

Search found 125 results on 5 pages for 'chassis'.

Page 4/5 | < Previous Page | 1 2 3 4 5  | Next Page >

  • Which version management design methodology to be used in a Dependent System nodes?

    - by actiononmail
    This is my first question so please indicate if my question is too vague and not understandable. My question is more related to High Level Design. We have a system (specifically an ATCA Chassis) configured in a Star Topology, having Master Node (MN) and other sub-ordinate nodes(SN). All nodes are connected via Ethernet and shall run on Linux OS with other proprietary applications. I have to build a recovery Framework Design so that any software entity, whether its Linux, Ramdisk or application can be rollback to previous good versions if something bad happens. Thus I think of maintaining a State Version Matrix over MN, where each State(1,2....n) represents Good Kernel, Ramdisk and application versions for each SN. It may happen that one SN version can dependent on other SN's version. Please see following diagram:- So I am in dilemma whether to use Package Management Methodology used by Debian Distributions (Like Ubuntu) or GIT repository methodology; in order to do a Rollback to previous good versions on either one SN or on all the dependent SNs. The method should also be easier for upgrading SNs along with MNs. Some of the features which I am trying to achieve:- 1) Upgrade of even single software entity is achievable without hindering others. 2) Dependency checks must be done before applying rollback or upgrade on each of the SN 3) User Prompt should be given in case dependency fails.If User still go for rollback, all the SNs should get notification to rollback there own releases (if required). 4) The binaries should be distributed on SNs accordingly so that recovery process is faster; rather fetching every time from MN. 5) Release Patches from developer for bug fixes, feature enhancement can be applied on running system. 6) Each version can be easily tracked and distinguishable. Thanks

    Read the article

  • How do I convert Data::Dumper output back into a Perl data structure?

    - by newbee_me
    Hi all! I was wondering if you could shed some lights regarding the code I've been doing for a couple of days. I've been trying to convert a Perl-parsed hash back to XML using the XMLout() and XMLin() method and it has been quite successful with this format. #!/usr/bin/perl -w use strict; # use module use IO::File; use XML::Simple; use XML::Dumper; use Data::Dumper; my $dump = new XML::Dumper; my ( $data, $VAR1 ); Topology:$VAR1 = { 'device' => { 'FOC1047Z2SZ' => { 'ChassisID' => '2009-09', 'Error' => undef, 'Group' => { 'ID' => 'A1', 'Type' => 'Base' }, 'Model' => 'CATALYST', 'Name' => 'CISCO-SW1', 'Neighbor' => {}, 'ProbedIP' => 'TEST', 'isDerived' => 0 } }, 'issues' => [ 'TEST' ] }; # create object my $xml = new XML::Simple (NoAttr=>1, RootName=>'data', SuppressEmpty => 'true'); # convert Perl array ref into XML document $data = $xml->XMLout($VAR1); #reads an XML file my $X_out = $xml->XMLin($data); # access XML data print Dumper($data); print "STATUS: $X_out->{issues}\n"; print "CHASSIS ID: $X_out->{device}{ChassisID}\n"; print "GROUP ID: $X_out->{device}{Group}{ID}\n"; print "DEVICE NAME: $X_out->{device}{Name}\n"; print "DEVICE NAME: $X_out->{device}{name}\n"; print "ERROR: $X_out->{device}{error}\n"; I can access all the element in the XML with no problem. But when I try to create a file that will house the parsed hash, problem arises because I can't seem to access all the XML elements. I guess, I wasn't able to unparse the file with the following code. #!/usr/bin/perl -w use strict; #!/usr/bin/perl # use module use IO::File; use XML::Simple; use XML::Dumper; use Data::Dumper; my $dump = new XML::Dumper; my ( $data, $VAR1, $line_Holder ); #this is the file that contains the parsed hash my $saveOut = "C:/parsed_hash.txt"; my $result_Holder = IO::File->new($saveOut, 'r'); while ($line_Holder = $result_Holder->getline){ print $line_Holder; } # create object my $xml = new XML::Simple (NoAttr=>1, RootName=>'data', SuppressEmpty => 'true'); # convert Perl array ref into XML document $data = $xml->XMLout($line_Holder); #reads an XML file my $X_out = $xml->XMLin($data); # access XML data print Dumper($data); print "STATUS: $X_out->{issues}\n"; print "CHASSIS ID: $X_out->{device}{ChassisID}\n"; print "GROUP ID: $X_out->{device}{Group}{ID}\n"; print "DEVICE NAME: $X_out->{device}{Name}\n"; print "DEVICE NAME: $X_out->{device}{name}\n"; print "ERROR: $X_out->{device}{error}\n"; Do you have any idea how I could access the $VAR1 inside the text file? Regards, newbee_me

    Read the article

  • NFS to NFS mount

    - by dude
    I have a machine that I need to bridge NFS files to. Can I mount an NFS directory on machine2 from machine1 and then mount the mounted NFS directory on machine2 on machine3 via NFS? Do you see any problems with that? I am basically bridging some subnet domains this way, in a certain fashion. My development machine is on a different and separate (unbridged) than where I would like to use the files, and I would like this machine1(dev machine) - machine2(passthrough machine) - machine3(test machine) connection. And no there is no way to move the test machine as it's a chassis :) and it's two buildings away.

    Read the article

  • One repository per table or one per functional section?

    - by Ian Roke
    I am using ASP.NET MVC 2 and C# with Entity Framework 4.0 to code against a normalised SQL Server database. A part of my database structure contains a table of entries with foreign keys relating to sub-tables containing drivers, cars, engines, chassis etc. I am following the Nerd Dinner tutorial which sets up a repository for dinners which is fair enough. Do I do one for drivers, one for engines, one for cars and so on or do I do one big one for entries? Which is the best practise for this type of work? I am still new to this method of coding.

    Read the article

  • 64-bit 13.10 shows 1GB less RAM than 64-bit 13.04 did

    - by kiloseven
    Multiple 64-bit versions (Kubuntu, Lubuntu and Xubuntu) once installed on my ThinkPad R60 show 3GB of RAM, not the correct 4GB of RAM. Last week with 13.04, I had 4GB of RAM (which matches the BIOS) and this week I have 3GB available. Inquiring minds want to know. Details follow: Linux R60 3.11.0-12-generic #19-Ubuntu SMP Wed Oct 9 16:20:46 UTC 2013 x86_64 x86_64 x86_64 GNU/Linux r60 free -m reports: _ total used free shared buffers cached Mem: 3001 854 2146 0 22 486 -/+ buffers/cache: 346 2655 Swap: 0 0 0 . . . . . . lshw shows: description: Notebook product: 9459AT8 () vendor: LENOVO version: ThinkPad R60/R60i serial: redacted width: 64 bits capabilities: smbios-2.4 dmi-2.4 vsyscall32 configuration: administrator_password=disabled boot=normal chassis=notebook family=ThinkPad R60/R60i frontpanel_password=unknown keyboard_password=disabled power-on_password=disabled uuid=126E4001-48CA-11CB-9D53-B982AE0D1ABB *-core description: Motherboard product: 9459AT8 vendor: LENOVO physical id: 0 version: Not Available *-firmware description: BIOS vendor: LENOVO physical id: 0 version: 7CETC1WW (2.11 ) date: 01/09/2007 size: 144KiB capacity: 1984KiB capabilities: pci pcmcia pnp upgrade shadowing escd cdboot bootselect socketedrom edd acpi usb biosbootspecification {snip} *-memory description: System Memory physical id: 29 slot: System board or motherboard size: 4GiB *-bank:0 description: SODIMM DDR2 Synchronous physical id: 0 slot: DIMM 1 size: 2GiB width: 64 bits *-bank:1 description: SODIMM DDR2 Synchronous physical id: 1 slot: DIMM 2 size: 2GiB width: 64 bits dpkg -l linux-* returns: Desired=Unknown/Install/Remove/Purge/Hold | Status=Not/Inst/Conf-files/Unpacked/halF-conf/Half-inst/trig-aWait/Trig-pend |/ Err?=(none)/Reinst-required (Status,Err: uppercase=bad) ||/ Name Version Description +++-======================================-=======================================-========================================================================== un linux-doc-3.2.0 (no description available) ii linux-firmware 1.79.6 Firmware for Linux kernel drivers ii linux-generic 3.2.0.52.62 Complete Generic Linux kernel un linux-headers (no description available) un linux-headers-3 (no description available) un linux-headers-3.0 (no description available) un linux-headers-3.2.0-23 (no description available) un linux-headers-3.2.0-23-generic (no description available) ii linux-headers-3.2.0-52 3.2.0-52.78 Header files related to Linux kernel version 3.2.0 ii linux-headers-3.2.0-52-generic 3.2.0-52.78 Linux kernel headers for version 3.2.0 on 64 bit x86 SMP ii linux-headers-generic 3.2.0.52.62 Generic Linux kernel headers un linux-image (no description available) un linux-image-3.0 (no description available) ii linux-image-3.2.0-52-generic 3.2.0-52.78 Linux kernel image for version 3.2.0 on 64 bit x86 SMP ii linux-image-generic 3.2.0.52.62 Generic Linux kernel image un linux-initramfs-tool (no description available) un linux-kernel-headers (no description available) un linux-kernel-log-daemon (no description available) ii linux-libc-dev 3.2.0-52.78 Linux Kernel Headers for development un linux-restricted-common (no description available) ii linux-sound-base 1.0.25+dfsg-0ubuntu1.1 base package for ALSA and OSS sound systems un linux-source-3.2.0 (no description available) un linux-tools (no description available)

    Read the article

  • New Netra SPARC T3 Servers

    - by Ferhat Hatay
    Today at the Mobile World Congress 2011, Oracle announced two new carrier-grade NEBS Level 3- certified servers: Oracle’s Netra SPARC T3-1 rackmount server and Oracle’s Netra SPARC T3-1BA ATCA blade server bringing the performance, scalability and power efficiency of the newest SPARC T3 processor to the communications market.    The Netra SPARC T3-1 server enclosure has a compact 20inch-deep carrier-grade rack-optimized design The new Netra SPARC T3 servers further expand Oracle’s complete portfolio for the communications industry, which includes carrier-grade servers, storage and application software to run operations support systems and service delivery platforms with easy migration capabilities and unmatched investment protection via the binary compatibility guarantee of the Oracle Solaris operating system. With advanced reliability, networking and security features built-in to Oracle Solaris – the most widely deployed carrier-grade OS – the systems announced today are uniquely suited for mission-critical core network infrastructure and service delivery. The world’s first carrier-grade system using the 16-core, 128-thread SPARC T3 processor, the Netra SPARC T3-1 server supports 2x the I/O bandwidth, 2x the memory and is 35 percent faster than the previous generation. With integrated on-chip 10 Gigabit Ethernet, on-chip cryptographic acceleration, and built-in, no-cost Oracle VM Server for SPARC and Oracle Solaris Containers for virtualization, the Netra SPARC T3-1 server is an ideal platform for consolidation, offering 128 virtual systems in a single server. As the next generation Netra SPARC ATCA blade, Netra SPARC T3-1BA ATCA blade server brings the PICMG 3.0 compatibility, NEBS Level 3 Certification, ETSI compliance and the Netra business practices to the customer solution. The Netra SPARC T3-1BA ATCA blade server can be mixed in the Sun Netra CT900 blade chassis with other ATCA UltraSPARC and x86 blades.     The Netra SPARC T3-1BA ATCA blade server   The Netra SPARC T3-1BA ATCA blade server delivers industry-leading scalability, density and cost efficiency with up to 36 SPARC T3 processors (3456 processing threads) in a single rack – a 50 percent increase over the previous generation. The Netra SPARC T3-1BA blade server also offers high-bandwidth and high-capacity I/O, with greater memory capacity to tackle the increasing business demands of the communications industry. For service providers faced with the rapid growth of broadband networks and the dramatic surge in global smartphone adoption, the new Netra SPARC T3 systems deliver continuous availability with massive scalability, tested and certified to run in the harshest conditions. More information Oracle’s Sun Netra Servers Scaling Throughput and Managing TCO with Oracle’s Netra SPARC T3-1 Servers Enabling End-to-End 10 Gigabit Ethernet in Oracle's Sun Netra ATCA Product Family Data Sheet: Netra SPARC T3-1BA ATCA Blade Server Data Sheet: Netra SPARC T3-1 Server Oracle Solaris: The Carrier Grade Operating System

    Read the article

  • Oracle’s Sun Server X4-8 with Built-in Elastic Computing

    - by kgee
    We are excited to announce the release of Oracle's new 8-socket server, Sun Server X4-8. It’s the most flexible 8-socket x86 server Oracle has ever designed, and also the most powerful. Not only does it use the fastest Intel® Xeon® E7 v2 processors, but also its memory, I/O and storage subsystems are all designed for maximum performance and throughput. Like its predecessor, the Sun Server X4-8 uses a “glueless” design that allows for maximum performance for Oracle Database, while also reducing power consumption and improving reliability. The specs are pretty impressive. Sun Server X4-8 supports 120 cores (or 240 threads), 6 TB memory, 9.6 TB HDD capacity or 3.2 TB SSD capacity, contains 16 PCIe Gen 3 I/O expansion slots, and allows for up to 6.4 TB Sun Flash Accelerator F80 PCIe Cards. The Sun Server X4-8 is also the most dense x86 server with its 5U chassis, allowing 60% higher rack-level core and DIMM slot density than the competition.  There has been a lot of innovation in Oracle’s x86 product line, but the latest and most significant is a capability called elastic computing. This new capability is built into each Sun Server X4-8.   Elastic computing starts with the Intel processor. While Intel provides a wide range of processors each with a fixed combination of core count, operational frequency, and power consumption, customers have been forced to make tradeoffs when they select a particular processor. They have had to make educated guesses on which particular processor (core count/frequency/cache size) will be best suited for the workload they intend to execute on the server.Oracle and Intel worked jointly to define a new processor, the Intel Xeon E7-8895 v2 for the Sun Server X4-8, that has unique characteristics and effectively combines the capabilities of three different Xeon processors into a single processor. Oracle system design engineers worked closely with Oracle’s operating system development teams to achieve the ability to vary the core count and operating frequency of the Xeon E7-8895 v2 processor with time without the need for a system level reboot.  Along with the new processor, enhancements have been made to the system BIOS, Oracle Solaris, and Oracle Linux, which allow the processors in the system to dynamically clock up to faster speeds as cores are disabled and to reach higher maximum turbo frequencies for the remaining active cores. One customer, a stock market trading company, will take advantage of the elastic computing capability of Sun Server X4-8 by repurposing servers between daytime stock trading activity and nighttime stock portfolio processing, daily, to achieve maximum performance of each workload.To learn more about Sun Server X4-8, you can find more details including the data sheet and white papers here.Josh Rosen is a Principal Product Manager for Oracle’s x86 servers, focusing on Oracle’s operating systems and software. He previously spent more than a decade as a developer and architect of system management software. Josh has worked on system management for many of Oracle's hardware products ranging from the earliest blade systems to the latest Oracle x86 servers.

    Read the article

  • Viewing at Impossible Angles

    - by kemer
    The picture of the little screwdriver with the Allen wrench head to the right is bound to invoke a little nostalgia for those readers who were Sun customers in the late 80s. This tool was a very popular give-away: it was essential for installing and removing Multibus (you youngsters will have to look that up on Wikipedia…) cards in our systems. Back then our mid-sized systems were gargantuan: it was routine for us to schlep around a 200 lb. desk side box and 90 lb. monitor to demo a piece of software your smart phone will run better today. We were very close to the hardware, and the first thing a new field sales systems engineer had to learn was how put together a system. If you were lucky, a grizzled service engineer might run you through the process once, then threaten your health and existence should you ever screw it up so that he had to fix it. Nowadays we make it much easier to learn the ins and outs of our hardware with simulations–3D animations–that take you through the process of putting together or replacing pieces of a system. Most recently, we have posted three sophisticated PDFs that take advantage of Acrobat 9 features to provide a really intelligent approach to documenting hardware installation and repair: Sun Fire X4800/X4800 M2 Animations for Chassis Components Sun Fire X4800/X4800 M2 Animations for Sub Assembly Module (SAM) Sun Fire X4800/X4800 M2 Animations for CMOD Download one of these documents and take a close look at it. You can view the hardware from any angle, including impossible ones. Each document has a number of procedures, that break down into steps. Click on a procedure, then a step and you will see it animated in the drawing. Of course hardware design has generally eliminated the need for things like our old giveaway tools: components snap and lock in. Often you can replace redundant units while the system is hot, but for heaven’s sake, you’ll want to verify that you can do that before you try it! Meanwhile, we can all look forward to a growing portfolio of these intelligent documents. We would love to hear what you think about them. –Kemer

    Read the article

  • Simulate 'Shock absorbtion' with tire rubber in PhysX (2.8.x)

    - by Mungoid
    This is a kinda tricky question and I fear there is no easy enough solution, but I figured I'd hit SE up before giving up on it and just doing what I can. A machine I am working on has no suspension or shocks or springs of any sort in the real machine, so you would think that when it drives over bumps, it would shake like crazy but because its tires (6 of them) are quite large they seem to absorb a lot of shock from the bumps. Part of this is because the machine is around 30k lbs and it just smashes/compresses any bumps in the ground down (This is another issue im still working on) and the other part is that the tires seem to have a lot of flex to them with a lot of air as well. So my current task is to simulate shock absorption in physx without visibly separating the tires from the spindle/axle.. I have been messing with all kinds of NxMaterial, NxSpring, Joints, etc. and have had no luck getting this to work. The main problem is that the spindle attached to the tire is directly in the center and the axle is basically solidly attached to the chassis, so if i give it any spring or suspension travel, that spindle on the tires will move upwards or downwards, looking very odd because now its not any longer in the center of the tire. I tried giving it a higher restitution but that just makes it bouncy without any shock absorption. Another avenue I am messing with is to actively smooth the terrain in front of the tires so that before it hits a bumpy patch, that patch is smoothed and it doesn't bounce. The only issue with this is that it is pretty expensive to do with 6 tires, high tesselation of the terrain and other complex things going on at the same time in this simulation. I am still working on this but I am hoping to mix and match a few different aspects to get the best possible outcome. This is a bit of a complex issue so I'm not expecting anyone to have a definitive answer, just hoping someone may think of something I haven't =-) -Side note: Yes i know PhysX 2.8.x is quite outdated but we have to stick with it for this implementation. We are in the process of going to another physics engine but it is out of scope to apply that engine to this project.

    Read the article

  • Have I bricked my Sun V20z?

    - by David Mackintosh
    I have a small pile of Sun V20z computers. I was trying to update the SP and BIOS firmwares in order to bring them all up to the same standard -- mostly to get the updated (ie actually useful) SP functionality, and figured that I would just do the BIOS while I was at it. For three of the four computers, it worked perfectly. However after the BIOS update, the fourth system won't boot. I did this: batch05-mgmt $ sp get mounts Local Remote /mnt 10.16.0.8:/export/v20z batch05-mgmt $ platform set os state update-bios /mnt/sw_images/platform/firmware/bios/V1.35.3.2/bios.sp This command may take several minutes. Please be patient. Bios started Bios Flash Transmit Started Bios Flash Transmit Complete Bios Flash update Progress: 7 Bios Flash update Progress: 6 Bios Flash update Progress: 5 Bios Flash update Progress: 4 Bios Flash update Progress: 3 Bios Flash update Progress: 2 Bios Flash update Progress: 1 Bios Flash update complete batch05-mgmt $ platform set power state on This command may take several minutes. Please be patient. After an hour of waiting, it still won't start. The chassis powers on, but beyond the fans spinning up and the hardware POST of the drives, nothing appears to happen. So if I try to re-flash the BIOS (on the theory that maybe something went wrong): batch05-mgmt $ platform set os state update-bios /mnt/sw_images/platform/firmware/bios/V1.35.3.2/bios.sp This command may take several minutes. Please be patient. Bios started Error. The operation timed out. Have I bricked it?

    Read the article

  • MultiPath configuration on RHEL5 and Clariion CX-300

    - by Kamil Z
    I have problem with discovering my FC-connected CX-300 storage. Frankly speaking I'm complete novice in FibreChannel, so step by step explanation would be appreciated. My configuration consist of two IBM HS20 blades with RHEL5.4 on board and 2x Qlogic ISP2422-based 4Gb Fibre Channel HBAs on each blade. As a FC switch there are two Brocades built in BladeCenter Chassis, and finally there is EMC Clariion CX-300. CX300, and Brocade switches should be configured properly, because they were working fine with previous configuration, which main defference was RHEL3 instead RHEL5.4 Below there is my output from several usefull commands: #lspci | grep Fibre 06:01.0 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) 06:01.1 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) #lsmod | grep qla qla2xxx 1084741 0 scsi_transport_fc 37577 1 qla2xxx scsi_mod 141717 10 scsi_dh,qla2xxx,sg,scsi_transport_fc,usb_storage,libata,mptspi,mptscsih,scsi_transport_spi,sd_mod #cat /proc/scsi/scsi Attached Devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: LSILOGIC Model: 1030 IM IM Rev: 1000 Type: Direct-Access ANSI SCSI revision: 02 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 I'd followed instructions from this site (editing /etc/multipath.conf), but i failed after multipath -ll - the output was empty. Do you have any suggestions about discovering FC Connected LUNs in such configuration?

    Read the article

  • Is it possible to shrink the size of an HP Smart Array logical drive?

    - by ewwhite
    I know extension is quite possible using the hpacucli utility, but is there an easy way to reduce the size of an existing logical drive (not array)? The controller is a P410i in a ProLiant DL360 G6 server. I'd like to reduce logicaldrive 1 from 72GB to 40GB. => ctrl all show config detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438006FD9A50 Cache Serial Number: PAAVP9VYFB8Y RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev C Firmware Version: 3.66 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Enabled Total Cache Size: 512 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 412476 MB Status: OK Logical Drive: 1 Size: 72.0 GB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 18504 Strip Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001C132E4BBDFAA6DAD13DA3 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 196 MB, / 12.0 GB, /usr 8.0 GB, /var 4.0 GB, /tmp 2.0 GB OS Status: LOCKED Logical Drive Label: AE438D6A5001438006FD9A50BE0A Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 Device Number: 250 Firmware Version: RevC WWID: 5001438006FD9A5F Vendor ID: PMCSIERA Model: SRC 8x6G

    Read the article

  • PXE booting LACP hosts on Force10 S50N with FTOS

    - by lolwutreddit
    Hardware: S50N Firmware: FTOS 8.4.2.6 Problem: We're trying to PXE boot some servers that are connected via port-channel interfaces with LACP. Current Work-around: we PXE boot a server with a single interface (eth0), and then use a Perl script to turn up the port-channel interfaces after the server is built. Details: Is anyone doing anything similar on Force10 S50 switches with FTOS? If not, is anyone doing this on another S series, or larger chassis-based Force10? I'm wondering if Native VLAN will solve this, since ports in a port-channel cannot explicitly have a VLAN set, and they don't seem to use the tagged or untagged VLAN that the port channel is in. I will confirm this next (I think it's the only thing I haven't tried) Juniper Example: http://broken.net/openindiana/how-to-pxe-boot-systems-on-lacp-using-juniper-switches/ Cisco: there are plenty of documented ways to solve this issue on IOS and Nexus Update/Edit: since there seems to be no way to use interface or port-channel mode commands to get the individual interfaces to show up in spanning-tree (rtsp in this case), the ports should never go into a forwarding state. I'm not going to mess with it anymore unless a) someone that has experience passes it on, or b) Force10 comes up with a solution for this (I'm guessing it will only be introduced on other S platforms (S55, S60), since the S50 seems to be near EOL). I'm basing that on the fact that the Open Automation type features are only being supported on the newer switches.

    Read the article

  • Dual Xeon Server voltages are low

    - by Mindflux
    I've got a whitebox server running CentOS 5.7. It's a Dual Xeon 5620, 24GB of RAM. The mainboard is a SuperMicro X8DT6-F and the chassis is a SC825TQ-R720LPB. Dual 720W Power supplies. We had a big power outage a couple weeks back that took down everything, I don't have any pre-power outage figures for this server, and the only reason I noticed these is because when I was bringing up the servers I was checking them out with more scrutiny than usual. http://i.imgur.com/rSjiw.png (Image of voltage readings) As you can see, CPU1 DIMM is low, +3.3V is high, 3.3VSB is high, +5v is high, +12v is REAL LOW (out of normal 5% (plus/minus))... and VBAT is off the charts. With my whitebox VAR we've tried the following: Swap out PSU with another server I have with the same PSUs. Try different power cord Update BMC/IPMI firmware in case readings were wrong (They aren't) Update BIOS Try different PDU Try a different outlet and/or circuit Replaced Voltage Regulator Unit At this point, the only thing we haven't done, seemingly is replace the mainboard.. which is what the next step will be unless something else shines some light on the situation. I should mention the system is rock solid otherwise which is a surprise given the 12v voltage is that far off.

    Read the article

  • Laptops with easy heat sink service?

    - by Niten
    Can you recommend a current laptop model with easy heat sink access – or better yet, a removable air intake filter – making it easy to periodically clean out the dust and lint that always packs up in these things? Every laptop I've owned has eventually overheated on account of a clogged heat sink. (I suppose it doesn't help that I have a cat who loves to hang out where I'm working, or that my laptop is almost always running.) One of the things I really love about my current system, a Dell Inspiron 1420n, is how easy it is to service its cooling system: whenever I notice the fan starting to work harder and the CPU temperature climbing higher than it should be, I merely have to unscrew a single panel from the bottom of the machine, clean out the heat sink, and then I'm good for another few months. Which current models of the "business laptop" variety offer similar easy cooling system service? I'm looking for something roughly along the lines of: 14- or 15-inch display Nehalem-based CPU Solid construction – magnesium chassis or better (like the Inspiron) TPM (for BitLocker) ideal, but not mandatory Docking adapter ideal, but not mandatory Good battery life For example, the ThinkPad T410 would have been my top choice, but it seems like it would be a serious chore to service its heat sink. For the current MacBook Pros it looks downright impossible. No matter how nice the laptop is in other respects, it'll be of no use to me when it's overheating. So, any suggestions? Thanks in advance... (I'm constantly surprised that customers and manufacturers don't pay more attention to this feature, at least in the business laptop subcategory. In the last couple months I've fixed two friends' laptops which were also overheating due to clogged cooling systems; clearly I'm not the only one affected by this.)

    Read the article

  • IDE/PATA high-speed hard drive dock

    - by wfaulk
    I frequently need to access bare drives for backups and need a quick, high-speed way to deal with them. There are a multitude of SATA hard drive docks (for example), but I have a lot of IDE/PATA (hereafter "IDE") drives that I would like to be able to use similarly. There are IDE-to-SATA adapters so you can plug your IDE hard drive into a SATA port, so I don't see any reason why you couldn't use the same technology to have a native dock, yet none seems to exist. Now, I'm aware that 3.5" IDE drives do not have a specification for the layout of the connector, and therefore can't be slapped into a dock the same way a SATA drive could, but 2.5" PATA drives do. In fact, I'm not terribly interested in supporting 3.5" drives. It would be nice, but I deal with them far less frequently than 2.5" drives. Also, I'd very much like for the connection to the computer be faster than USB, preferably eSATA, I don't want to be spending time mounting a drive inside an enclosure, I don't want bare drives lying around with a cable hanging off of them, and I'd prefer a single dock rather than two. What seems like the ideal solution to me would be a regular SATA→eSATA dock and some sort of screwless adapter for IDE drives, but I'm open to any suggestions, regardless of my stated preferences, but which are, in some sort of order of preference: high-speed (faster than USB, at least) holder for drive (not just a cable) no complicated enclosure support for 3.5" IDE drives single dock Updates: Here's a 3.5" IDE to 3.5" SATA docking adapter that could be part of the solution. Weird. I figured that would be the impossible part. I was hoping to find something like this 2.5" to 3.5" SATA chassis that would take a 44-pin IDE drive internally. It looks like the Vantec EZ Swap EX comes awfully close. It has its own bay dock, but it looks like the SATA ports on the back are spaced properly, even if they're not aligned quite properly. Unfortunately, the proper position is at the very edge of the drive, which means that the docks' connectors are at the very edge of their recesses, which means there's no way to fit it in there.

    Read the article

  • Fast Ethernet module for Cisco 2620

    - by Kenny Rasschaert
    I have a Cisco 2620 Router. It comes with one fast ethernet port built in (circled in red), and one old AUI ethernet module is installed (circled in blue). I figure I can put a transceiver on the AUI interface to get a second RJ45 connector. What I'd really like to have is a second fast ethernet connector. The ideal candidate to achieve this would be the NM-1FE-TX module. Cisco claims on their website that this module is not suitable for the Cisco 2620 and Cisco 2620XM. It says so in "Table 2 Physical Limitation of Serial Modules per Chassis". Indeed, this module was designed for the 3600 series of routers. I've seen claims on the internet, however, of people having this module on a 2620XM, and it being fully functional. This claim gains some credibility because of the fact that in Cisco's own Packet Tracer software, you can install this module on the 2620XM router. I'm looking for a definitive answer. Will this module work on a Cisco 2620? Is there perhaps another way to get a second fast ethernet port on this device?

    Read the article

  • does my machine configuration make sense?

    - by user1227914
    i couldn't think of a better place to ask this question, so here it goes. we're putting together a dedicated server for a website that will initially host the web server and the mysql database. as the website grows, we'll move the database to a different server and this machine will eventually only server the actual website. so the question is ...does my configuration look okay? it's the first time i'm building a server from scratch so i want to make sure i don't combine components that don't fit or something. things like ..do the drives i picked work for the hot swap ..etc. what do you guys think? am i good to go with this configuration? :) Chassis: Supermicro SuperServer 6016T-MTHF (6x DDR3 SDRAM - ECC DIMM 240-pin, 2x LGA1366 Socket, Power Provided: 600 Watt, 4 (free) x hot-swap - 3.5") CPU: Intel BX80614E5620 Xeon E5620 Processor - 4 Core, 2.40GHz, LGA 1366, 5.86GT/s QPI 12MB Cache, 64-Bit, 80W, HyperThreading Memory: Crucial CT51272BB1339 4GB PC10600 DDR3 Memory - 1333MHz, ECC, Registered, 1x4096MB (possibly 3 or 4 of them) Hard Drives: Western Digital WD2002FAEX Caviar Black Hard Drive - 2TB, 3.5", SATA 6Gbps, 7200 RPM, 64MB (possibly 2 or 3). thank you very much for any professional advice :)

    Read the article

  • How do I make ESXi 5.0 to shutdown virtual machines when the physical power button is pushed?

    - by Pawel Sawicki
    I have a home NAS/DLNA server built out of an HP Micro Server with the HP branded VMware ESXi 5.0.0 build-623860 (free license) installed. Being a home media center I'd like it to be "manageable" by all my household members. This requires that it needs to be powered on an off (including all the VMs inside) by anybody with the physical access to the server by simply pressing the power button on the chassis. The "startup" part is easy to obtain - all I had to do was to configure the startup/shutdown policy: Once the server powers up, all VMs start as well and that's exactly what I need. Well.. it did work up until 5.0.0U1, but that's a different story: http://blogs.vmware.com/vsphere/2012/03/free-esxi-hypervisor-auto-start-breaks-with-50-update-1.html Unfortunately, pressing the power button doesn't gracefully shutdown the guest machines - they are terminated instead. If I run the "shut down" command from the vSphere Client interface guests are powered off. I'd like to get the same end result when the physical power button is switched. I've poked around a bit on the ESXi server. There's a "/sbin/shutdown.sh" script that seemed to do exactly what I need... but after trying it does exactly what the power off button. The "/etc/inittab" contains an entry for the "shutdown" level but I suppose it's not hooked to the power button. I can't find any acpi related configuration, neither do I know what exactly is executed when the power button is pressed. Does anybody have a clue how can I make the VMs shutdown automatically when the physical power switch is pressed to turn of the computer?

    Read the article

  • Is there any free software to check for issues with a DVD drive?

    - by AgentConundrum
    I don't usually play movies on my laptop (prefer the standalone with the tv), but I tried to watch one the other night, and noticed playback was really choppy and had audio artifacts in places. I thought it could be related to memory issues so I rebooted and tried again, but the results were the same. I considered that it could be an issue with the disc, so I tried to clean it but again there was no change. I don't think the problem is with the disc, because I tried another disc and it also had the same problem. I don't think I've ever watched the second disc since I've had it, so it should have been safe in its jewel case. Also, there were no issues when I watched an episode off the first disc in my standalone player. What I'm wondering is: are there are any (free) utilities that can check for issues with the drive itself? I looked around but most of the software I found focuses on integrity checks for the disc, not the drive. I have had issues with this laptop recently (had to replace the keyboard when the cat damaged it while I was cleaning dust out and the machine was ripped apart, also replaced part of the chassis after I cracked it when I tried to open it not knowing a screw was still in it) so I may have just replaced the drive incorrectly. I'm going to check on this while I await an answer to this question. Thanks.

    Read the article

  • My New Dell Workstation T-7500 gives electric shock

    - by Dan
    Just bought Dell T-7500 Workstation. When installation technician came to Install the workstation, he got an electric shock when he touched the Start Button. He also got shock when he touched Front Panel. No shock when touching rest of the Chassis. He called Dell Support & tried to troubleshoot by taking out various wires etc but did not help. I touched the same places & I also got shock. We checked everything possible including connecting to various outlets but it didn't solve the problem. Installation subcontractor said that they are not supposed to troubleshoot anything on new system, just install it & they made notes & left. I called my sales guy & it was weekend so he said he will take care of it on Monday. Here are my concerns : (1) Why does that happen ? Although it is a mild shock & it won't kill you but might damage other parts of workstation ? (2) Is this common for workstations ? (3) What should I do ? Of course Dell will try to troubleshoot again but should I let them do that OR ask for a New System ? (4) Wheat would happen if I continue using it till the new system arrives ? Thank You.

    Read the article

  • Best way to execute a command after Linux system halt

    - by Lukas Loesche
    Problem: The SSDs in our servers require a power cycle (i.e. off/on, not reset/warm reboot) after a firmware update. Thoughts: Using 'ipmitool chassis power cycle' I can cycle the server's power. However this would cut the power while the system is still running, filesystems are mounted, etc. What I basically want is a delayed power cycle so the system has a change to halt. But I guess that would have to be implemented on the server's IPMI board, so it's not really an option. My initial idea was to dynamically create a ramdisk containing the tool and libs and somehow integrate that into the halt process. I saw there's a /etc/init.d/halt, so that would be my starting point. Although I believe the kernel at some point in the shutdown process starts to kill off remaining processes. So I'm not even sure if that's a viable way. Question: What would be the best way to execute ipmitool (or any other command), after the system has halted and all regular filesystems are unmounted?

    Read the article

  • Small TCP Window on WAN between 2 Locations

    - by Brent
    Site A: Denver datacenter. 60MBPS. Site B: Chicago. 100MBPS. ICMP pings: Packets: Sent = 176, Received = 176, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 74ms, Maximum = 94ms, Average = 75ms File transfer between sites that never goes past ~7MBPS: Windows Update download at 60MBPS+: Site to site: IPSec VPN using two Cisco 5520's. CPU at 3-4% and lots of memory to spare. The latency between to two sites is very acceptable so I can't see an issue why it is performing so slow when transferring between the two sites. I have found that any type of transfer (FTP, HTTP, Windows file shares) will never go above ~7MBPS. When the WAN was first setup, I was able to get transfers at 50-60MBPS, which is what is expected due to the WAN connection at the Site A at 60MBPS. Then a few days later, I was not able to get anything going faster than ~7MBPS. Is there a upstream router between Denver and Chicago causing this? I want to take the blame away from our setup as downloads from Windows Update go blazing fast and for the first few days after the site to site VPN came up, I was transferring VM images at 50-60MBPS. Our stack: HP P2000 MSA - HP C7000 Chassis - HP Flex-10 - Cisco Gigabit switch - Cisco ASA - WAN

    Read the article

  • Cisco Access switch is dropping large amount of end points

    - by user135458
    This afternoon, with no changes to the network, a switch suddenly started dropping off lots of connections. These connections would come back up a few minutes later, then another area connected to the switch would drop off. This is an older 4006 chassis switch which could in and of itself be a problem but I'm looking to see what else you all would look for in trying to find a root cause. Switch is connected via ports 1/1 and 1/2 in an etherchannel to a VSS core 1/1/42 and 2/1/42. Both sides are up and working however the CPU on the switch will spike up to 99% and that's when CRC errors start to hit the VSS core on one of those interfaces and end points start dropping off. We tried new transceivers and SFP's on each side of the link, same result. When we tried swapping the fiber patch cables on the access switch the CRC errors did not follow the fiber cables they stayed with port 1/2 on the access switch. So port 1/2 on the supervisor module looks like the culprit. We actually tried to create a new member of the ethernet channel by taking a fiber media converter to cat5 and make that a member of the port-channel but when we plugged it in you couldn't even reach the switch. I'm guessing that's unrelated and a problem with the media converter. As of right now we have left it in a state of only one fiber cable running to one side of the VSS core (1/1 Access Switch -- 2/1/42). I've sent some info into TAC and they are looking into the situation but does anyone else have any commands I could run or some troubleshooting I could look into in the meantime?

    Read the article

  • What are my options in replacing the noisy fan in my Linksys Cisco SRW2008P managed GigE switch?

    - by Fred Sobotka
    My first managed GigE switch, the Linksys SRW2008, was a dream, until it started randomly chattering on various ports. That started while I was on the road all the time, which made it take forever to diagnose, but that's a different problem. When I finally determined that the switch was bad, it was still covered by warranty by Linksys/Cisco, so I opened an RMA ticket and returned it. Unfortunately, Linksys/Cisco "upgraded" my replacement switch to a SRW2008P, which has Power over Ethernet features I never planned on using. That by itself wasn't so bad, but it's my guess that the inclusion of PoE functions in this model required a tiny, super-loud internal fan to keep everything cool. This wasn't something I wanted or asked for, but, now that I am stuck with it, I am investigating options for replacing that little internal fan with something far quieter. For example, if I attach a larger fan to the outsite of the chassis, I think it could push enough air to replace the stock fan that is currently there. Any advice on carrying this out? I have no interest in melting my switch due to insufficient ventilation.

    Read the article