Search Results

Search found 30252 results on 1211 pages for 'close process'.

Page 4/1211 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Looking for way to log process terminations on OS X (Mac)

    - by Stan Sieler
    I'm looking for a way to log all process terminations on my Mac (OS X 10.6.8). (And see pid, timestamp, process name) I've implemented something similar for HP-UX, but it required a kernel-level driver and intercepting several variations of "exit()" (the normal one, and the one invoked on behalf of a process while it's aborting). Why do I want the info? I've been seeing messages in my system log file (dmesg) like: CODE SIGNING: cs_invalid_page(0x1000): p=91550[GoogleSoftwareUp] clearing CS_VALID CODE SIGNING: cs_invalid_page(0x1000): p=92088[GoogleSoftwareUp] clearing CS_VALID Although dmesg lacks timestamps, apps/Utilities/Console : Database : all : search for CS_VALID shows that the messages appears about once every 58 1/2 minutes. I suspect the number after "p=" is a process id (pid) ... but for a process that has long since terminated by the time I see the message. So, if there was a process termination log mechanism that recorded the pid, the time of termination, the reason for termination, and the process name (at time of termination), that would probably allow me to determine who's causing those errors to be logged! (No, I'm not running Chrome on my Mac, and "ps -ef | grep -i goog" gets no hits either ... I'm not consciously running any Google apps on the Mac) thanks, Stan [email protected]

    Read the article

  • bad file descriptor with close() socket (c++)

    - by user321246
    hi everybody! I'm running out of file descriptors when my program can't connect another host. The close() system call doesn't work, the number of open sockets increases. I can se it with cat /proc/sys/fs/file-nr Print from console: connect: No route to host close: Bad file descriptor connect: No route to host close: Bad file descriptor .. Code: #include <stdio.h> #include <stdlib.h> #include <sys/socket.h> #include <netinet/in.h> #include <netdb.h> #include <string.h> #include <iostream> using namespace std; #define PORT 1238 #define MESSAGE "Yow!!! Are we having fun yet?!?" #define SERVERHOST "192.168.9.101" void write_to_server (int filedes) { int nbytes; nbytes = write (filedes, MESSAGE, strlen (MESSAGE) + 1); if (nbytes < 0) { perror ("write"); } } void init_sockaddr (struct sockaddr_in *name, const char *hostname, uint16_t port) { struct hostent *hostinfo; name->sin_family = AF_INET; name->sin_port = htons (port); hostinfo = gethostbyname (hostname); if (hostinfo == NULL) { fprintf (stderr, "Unknown host %s.\n", hostname); } name->sin_addr = *(struct in_addr *) hostinfo->h_addr; } int main() { for (;;) { sleep(1); int sock; struct sockaddr_in servername; /* Create the socket. */ sock = socket (PF_INET, SOCK_STREAM, 0); if (sock < 0) { perror ("socket (client)"); } /* Connect to the server. */ init_sockaddr (&servername, SERVERHOST, PORT); if (0 > connect (sock, (struct sockaddr *) &servername, sizeof (servername))) { perror ("connect"); sock = -1; } /* Send data to the server. */ if (sock > -1) write_to_server (sock); if (close (sock) != 0) perror("close"); } return 0; }

    Read the article

  • Kill process started with System.Diagnostic.Process.Start("FileName")

    - by PedroC88
    Hello; I am trying to create an app that will perform actions on specific times (much like the Windows Task Scheduler). I am currently using Process.Start() to lunch the file (or exe) required by the task. I am initiating a process by calling a file (an .mp3) and the process starts WMP (since it is the default application), so far so good. Now I wan't to kill that process. I know that it is normal behavior for the Process.Start(string, string) to return nothing (null in C#) in this case. So I am asking how can i close WMP when I called it through Process.Start(string, string)?? Edit: Please note that I am not opening WMP directly with Process.Start() and this is the line with which I run the process: VB: Me._procs.Add(Process.Start(Me._procInfo)) C#: this._procs.Add(Process.Start(this._procInfo)) _procInfo is a ProcessStartInfo instance. _procInfo.FileName is "C:\route\myFile.mp3". That is why WMP opens. In any case, all of the Start() methods, except for the instance-one which returns a boolean, return nothing (null in C#), because WMP is not the process that was directly created (please note that WMP is run and the song does play).

    Read the article

  • Capture window close event

    - by -providergordienko.vladimir
    I want to capture events that close editor window (tab) in Visual Studio 2008 IDE. When I use dte2.Application.Events.get_CommandEvents(null, 0).BeforeExecute I successfully captured such events: File.Close File.CloseAllButThis File.Exit Window.CloseDocumentWindow and others. If code in window is not acceptable, I stop the event (CancelDefault = true). But if I click "X" button on the right hand side, "Save Changes"; dialog appears, tab with editor window close and I have no any captured events. In this case I can capture WindowClosing event, but can not cancel the event. Is it poosible to handle "x" button click and stop event?

    Read the article

  • Run Oracle E-Business Suite Period Close Diagnostic

    - by Get Proactive Customer Adoption Team
    Untitled Document Be Proactive & Save Time—Use the Period Close Diagnostic During the Month Have you ever closed your books at the end of the month and, due to problems with your Oracle E-Business Suite Period Close, you found yourself working all night or all weekend to resolve your issues? You can avoid issues by running the Oracle E-Business Suite Period Close Diagnostics throughout the month, prior to closing Oracle Financial Assets, General Ledger, Payables, and/or Receivables. You can identify issues that will interfere with your period close early, preventing last minute fire drills. Correct your errors or, if you need Oracle Support’s assistance, attach the output to a service request for faster resolution by the support engineer. Oracle E-Business Suite Diagnostics are included in your Oracle Premier Support agreement at no extra charge. They are proactive, easy to use, tools provided by Oracle Support to ease the gathering and analyzing of information from your E-Business Suite, specific to an existing issue or setup. Formatted output displays the information gathered, the findings of the analysis, and the appropriate actions to take if necessary. These tools are designed for both the functional and technical user, providing no EBS administration features, so you can safely assign this responsibility to users who are not administrators. A good place to start with the Support Diagnostics is the install patch Note 167000.1. Everything you need is in this patch and you install it on top of your E-Business Suite. If you are on EBS 12.0.6 or below, Oracle delivers the diagnostic tests in a standard Oracle patch and you apply it using the adpatch utility. If you are on EBS release 12.1.1 or above, your diagnostics are already there. Oracle E-Business Suite Diagnostics: Prevent Issues—resolving configuration and data issues that would cause processes to fail Identify Issues Quickly—resolving problems without the need to contact Oracle Support Reduce Resolution Time—minimizing the time spent to resolve an issue by increasing support engineer efficiency In the example below, you will see how to run the EBS Period Close Diagnostic step-by-step using an SQLGL Period Closing Activity Test. This allows you to check throughout the month to identify and resolve any issue that might prevent closing the period in the General Ledger on schedule.   Click the Select Application button. Select your Application. In this example, we will use the Period Close test. Scroll down to Period Close Place a check mark in the Period Closing box in the Select column. Click the Execute button at the bottom of the page Input the parameters. Click the Submit button Click the Refresh button, until the Status of the test changes from “In Progress” to “Completed” Click the icon under, View Report to view the test results   The report will complete successfully or show completed with errors. The report will show where the error is located, what the error is, and what action(s) to take for resolution. Remember, if you need to work with Oracle Support to resolve your issue, attach the report to your Service Request so the engineer can start working the issue. Completed with errors Completed successfully with no errors If you have questions, please ask in the E-Business Suite Category’s Diagnostic Tools Community. You may find the answer waiting for you in a prior community discussion or in one of the resources posted by an Oracle Support moderator. Oracle’s Period Close Diagnostic, and the other E-Business Suite Diagnostics, save you time and help keep you on schedule. If you run the Period Close Diagnostic throughout the month, you can identify issues to resolve and get help, if needed. When opening a Service Request, attaching the output from the diagnostic report, speeds resolution. With the issues resolved ahead of time, your Period Close should complete without errors. Avoiding the unexpected, helps to close your books on time and without late nights or working through your weekend. Recommended Reads E-Business Suite Diagnostics Period / Year End Close [ID 402237.1] lists all of the Closing Period Diagnostic Tests. I highly recommend that customers execute these tests prior to closing a period. The period closing tests listed in this document help you identify known issues that prevent a successful period close. Use these tests prior to closing a period. To learn about all the available EBS Diagnostics, please review the E-Business Suite Diagnostics Overview [ID 342459.1].

    Read the article

  • Cannot Kill Process in Vista 64

    - by JanSolo
    Hi I have a weird situation where a Zombie process is causing my Vista64 Dev machine to become useless. I use Incredibuild 3.40 to distribute builds of a large software product that I work on. Occasionally, a build will fail and a Zombie process is left behind. The process holds a handle to a file that is needed by the build system to retry the build. Since I cannot kill the process, the handle remains open and I cannot build my code at all. I've tried TargetManager and ProcessExplorer, but neither can kill this process. It gets worse; since Vista cannot kill all its processes, my PC refuses to shut down correctly, requiring a hard reboot after each failed build. Is there a way to really-really-kill a process in Vista? Or maybe a way to force a file handle to close? Any help is appreciated. Cheers Jan. EDIT: This is still occurring. I've used Lockhunter (which appears to successfully unlock the file handle), but retrying the build still fails because the (now unlocked) file cannot be deleted. Explorer and Lockhunter both fail to delete the file. LockHunter also tells me that there are no processes that hold handles to it. Basically, nothing owns it, but you still cant delete it. This sucks.

    Read the article

  • handle exit event of child process

    - by Ehsan
    I have a console application and in the Main method. I start a process like the code below, when process exists, the Exist event of the process is fired but it closed my console application too, I just want to start a process and then in exit event of that process start another process. It is also wired that process output is reflecting in my main console application. Process newCrawler = new Process(); newCrawler.StartInfo = new ProcessStartInfo(); newCrawler.StartInfo.FileName = configSection.CrawlerPath; newCrawler.EnableRaisingEvents = true; newCrawler.Exited += new EventHandler(newCrawler_Exited); newCrawler.StartInfo.Arguments = "someArg"; newCrawler.StartInfo.WindowStyle = ProcessWindowStyle.Hidden; newCrawler.StartInfo.UseShellExecute = false; newCrawler.Start();

    Read the article

  • Does this factory method pattern example violate open-close?

    - by William
    In Head-First Design Patterns, they use a pizza shop example to demonstrate the factory method pattern. public abstract class PizzaStore { public Pizza orderPizza(String type) { Pizza pizza; pizza = createPizza(type); pizza.prepare(); pizza.bake(); pizza.cut(); pizza.box(); return pizza; } abstract Pizza createPizza(String type) } public class NYPizzaStore extends PizzaStore { Pizza createPizza(String item) { if (item.equals("cheese") { return new NYStyleCheesePizza(); } else if (item.equals("veggie")) { return new NYStyleVeggiePizza(); } else if (item.equals("clam")) { return new NYStyleClamPizza(); } else if (item.equals("pepperoni")) { return new NYStylePepperioniPizza(); } else return null; } } I don't understand how this pattern is not violating open-close. What if we require a beef Pizza, then we must edit the if statement in the NYPizzaStore class.

    Read the article

  • C# Process Exited event not firing from within webservice

    - by davidpizon
    I am attempting to wrap a 3rd party command line application within a web service. If I run the following code from within a console application: Process process= new System.Diagnostics.Process(); process.StartInfo.FileName = "some_executable.exe"; // Do not spawn a window for this process process.StartInfo.CreateNoWindow = true; process.StartInfo.ErrorDialog = false; // Redirect input, output, and error streams process.StartInfo.UseShellExecute = false; process.StartInfo.RedirectStandardOutput = true; process.StartInfo.RedirectStandardError = true; process.StartInfo.RedirectStandardInput = true; process.EnableRaisingEvents = true; process.ErrorDataReceived += (sendingProcess, eventArgs) => { // Make note of the error message if (!String.IsNullOrEmpty(eventArgs.Data)) if (this.WarningMessageEvent != null) this.WarningMessageEvent(this, new MessageEventArgs(eventArgs.Data)); }; process.OutputDataReceived += (sendingProcess, eventArgs) => { // Make note of the message if (!String.IsNullOrEmpty(eventArgs.Data)) if (this.DebugMessageEvent != null) this.DebugMessageEvent(this, new MessageEventArgs(eventArgs.Data)); }; process.Exited += (object sender, EventArgs e) => { // Make note of the exit event if (this.DebugMessageEvent != null) this.DebugMessageEvent(this, new MessageEventArgs("The command exited")); }; process.Start(); process.StandardInput.Close(); process.BeginOutputReadLine(); process.BeginErrorReadLine(); process.WaitForExit(); int exitCode = process.ExitCode; process.Close(); process.Dispose(); if (this.DebugMessageEvent != null) this.DebugMessageEvent(this, new MessageEventArgs("The command exited with code: " + exitCode)); All events, including the "process.Exited" event fires as expected. However, when this code is invoked from within a web service method, all events EXCEPT the "process.Exited" event fire. The execution appears to hang at the line: process.WaitForExit(); Would anyone be able to shed some light as to what I might be missing?

    Read the article

  • Close smartpart view

    - by Ravi
    I am developing windows Forms application, for this i am using SmartClient. Here i click workspace close('X') event at the time i want to display messageBox based on user input (OK/Cancel) i have to decide pane has to be close or not.

    Read the article

  • Install Shield 2009 Premier, Uninstall doesn't close the process/gui

    - by Samir
    My application (developed using C#.net) is open now i uninstall, InstallShield gives message stating the application is already open and whether really want to close the application. Selection 'Ignore' continues uninstall. Some files and the exe of the application are not closed. How to close them by installshield on uninstall. Or there are some properties I have to set. I know adding a custom action at uninstall i can kill the process, but shouldn't installshield do it?

    Read the article

  • Does close ever throw an IOException?

    - by TofuBeer
    After providing some answers here, and reading some comments, it would seem that, in practice IOException is never thrown on close for file I/O. Are there any cases in which calling close on a Stream/Reader/Writer actually throws an IOException? If an exception is actually thrown, how should it be dealt with?

    Read the article

  • Cannot login to Ubuntu 14.04 returns to the login screen

    - by Safder
    I updated to 14.04 from 12.04.03. I was using cinammon at that time. When I upgraded to 14.04 ,I got a serious problem. I was unable to login, as whenever I hit enter after entering password, it is taking me straight to login screen again.I unable to login like Guest even. So, here is my .xsession-errors file. possibly anyone could help. Thanks in advance. Script for ibus started at run_im. Script for auto started at run_im. Script for default started at run_im. init: at-spi2-registryd main process ended, respawning init: at-spi2-registryd main process ended, respawning init: at-spi2-registryd main process ended, respawning init: at-spi2-registryd main process ended, respawning init: at-spi2-registryd main process ended, respawning init: at-spi2-registryd main process ended, respawning init: at-spi2-registryd main process ended, respawning init: at-spi2-registryd main process ended, respawning init: at-spi2-registryd main process ended, respawning init: at-spi2-registryd main process ended, respawning init: at-spi2-registryd respawning too fast, stopped init: gnome-settings-daemon main process (14717) killed by TRAP signal init: gnome-settings-daemon main process ended, respawning init: update-notifier-crash (/var/crash/_usr_bin_gnome-session.1000.crash) main process (14607) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_ibus_ibus-x11.1000.crash) main process (14623) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_x86_64-linux-gnu_bamf_bamfdaemon.1000.crash) main process (14663) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_ibus_ibus-ui-gtk3.1000.crash) main process (14620) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_gnome-session_gnome-session-check-accelerated.1000.crash) main process (14612) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_gnome-settings-daemon_gnome-settings-daemon.1000.crash) main process (14616) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_unity_unity-panel-service.1000.crash) main process (14629) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_unity-settings-daemon_unity-settings-daemon.1000.crash) main process (14625) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_update-notifier_system-crash-notification.1000.crash) main process (14662) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_gnome-session_gnome-session-check-accelerated.127.crash) main process (14613) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_share_apport_apport-gtk.1000.crash) main process (14665) terminated with status 133 init: update-notifier-crash (/var/crash/linux-image-3.13.0-24-generic.0.crash) main process (14606) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_bin_Xorg.0.crash) main process (14609) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_ibus_ibus-x11.127.crash) main process (14624) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_ibus_ibus-ui-gtk3.127.crash) main process (14622) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_gnome-settings-daemon_gnome-settings-daemon.127.crash) main process (14618) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_unity-settings-daemon_unity-settings-daemon.127.crash) main process (14628) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_x86_64-linux-gnu_bamf_bamfdaemon.127.crash) main process (14664) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_bin_gnome-session.127.crash) main process (14608) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_lib_unity_unity-panel-service.127.crash) main process (14634) terminated with status 133 init: update-notifier-crash (/var/crash/_usr_share_apport_apport-gtk.127.crash) main process (14667) terminated with status 133 init: gnome-settings-daemon main process (14843) killed by TRAP signal init: gnome-settings-daemon main process ended, respawning init: gnome-settings-daemon main process (14850) killed by TRAP signal init: gnome-settings-daemon main process ended, respawning init: gnome-session (GNOME) main process (14727) killed by TRAP signal init: gnome-settings-daemon main process (14859) killed by TRAP signal init: logrotate main process (14570) killed by TERM signal init: upstart-dbus-session-bridge main process (14683) terminated with status 1 init: Disconnected from notified D-Bus bus

    Read the article

  • What quality standards to consider for software development process?

    - by Ron-Damon
    Hi, i'm looking for metrics/standards/normatives to evaluate a given "Software Development Process". I'm NOT looking to evaluate the SOFTWARE itself (trough SQUARE and such), i'm trying to evaluate software development PROCESS. So, my question is if you could give me some pointers to find this standard, considering that "evaluation objetives" would be documentation quality, how good is the customer relation, how efective is the process, etc. Very much like a ISO 9000, and like CMMI on a sense, but much lightweight and concrete and process oriented, not company oriented. Please help, i'm trying to stablish the advantages of our development process as formal as i can.

    Read the article

  • Prompt User before browser close?

    - by JM4
    We have an administrative portal that our teachers constantly forget to download their latest PDF instructions before logging out and/or closing the browser window. I have looked around but can't find what I'm looking for. I want to accomplish the following goals: Goal 1 Before a user can close the browser window, they are prompted "Did you remember to download your form?" with two options, yes/no. If yes, close, if no, return to page. Goal 2 Before a user can click the 'logout' button, they are prompted with the same as above. My first pass at the very basic code (which does not work for browser close) is: <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html xmlns="http://www.w3.org/1999/xhtml"> <head> <meta http-equiv="Content-Type" content="text/html; charset=utf-8" /> <title>Untitled Document</title> <script type="text/javascript"> function init() { if(window.addEventListener) { window.addEventListener("beforeunload", unloadMess, false); } else if(window.onbeforeunload) { window.onbeforeunload = unloadMess; }; } function unloadMess() { var User_Message = "[Your user message here]" return User_Message; } </script> </head> <body onload="init();"> hello this is my site </body> </html> anybody ever come across a good solution?

    Read the article

  • how close a connection from server side that created by ajax from client side

    - by saeid
    I have this sample php code: <?php function response($a) { @ob_end_clean(); header("Connection: close"); ob_start(); echo $a; $length = ob_get_length(); header("Content-Length: $length"); ob_end_flush(); flush(); } response("test1"); sleep(5); echo "test2"; ?> now I make a connection to server from client by ajax. now I want to server only send "test1" to me and then close the connection. but connection not closed and wait 5 seconds and send me "test1 test2" !! this is response headers from server to me : X-Powered-By: PHP/5.3.27 Connection: close Vary: Accept-Encoding,User-Agent Content-Encoding: gzip Cache-Control: private, no-cache, no-store, ------revalidate, no-transform Transfer-Encoding: chunked Content-Type: text/html in response headers I do not see Content-Length header. is problem for this ?? or if not what I must do now for solving problem ??

    Read the article

  • BPM PS6 video showing process lifecycle in more detail (30min) by Mark Nelson

    - by JuergenKress
    If the five minute video I shared last week has whet your appetite for more, then this might be just what you are looking for! The same international team that has made that video - Andrew Dorman, Tanya Williams, Carlos Casares, Joakim Suarez and James Calise – have also created a thirty minute version that walks through in much more detail and shows you, from the perspective of various business stakeholders involved in process modeling, exactly how BPM PS6 supports the end to end process lifecycle. The video centres around a Retail Leasing use case, and follows how Joakim the Business Analyst, Pablo the Process Owner, and James the Process Analyst take the process from conception to runtime, solely through BPM Composer, without the need for IT or the use of JDeveloper. Joakim, the Business Analyst, models the process, designs the user interaction forms, and creates business rules, Pablo, the Process Owner, reviews the process documentation and tests the process using the new ‘Process Player’, James, the Process Analyst, analyses the process and identifies potential bottle necks using ‘Process Simulation’. Read the full article here. SOA & BPM Partner Community For regular information on Oracle SOA Suite become a member in the SOA & BPM Partner Community for registration please visit www.oracle.com/goto/emea/soa (OPN account required) If you need support with your account please contact the Oracle Partner Business Center. Blog Twitter LinkedIn Facebook Wiki Mix Forum Technorati Tags: BPM PS6,BPM,SOA Community,Oracle SOA,Oracle BPM,Community,OPN,Jürgen Kress

    Read the article

  • ?? Oracle E-Business Suite Period Close ??

    - by Steve He(???)
    v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} w\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} Normal 0 7.8 ? 0 2 false false false EN-US ZH-CN X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:????; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman","serif";} ?? & ???? — ?? Period Close ???? ????????,??Oracle??????Period Close???,????????????????????????????Oracle E-Business Suite?Period Close?????,???Oracle Financial Assets, General Ledger, Payables, ? Receivables????????????????????????????????????,???????????????????,?????Oracle?????,??????????????,????????????? Oracle???????????????Oracle??????,???????????Oracle?????????????????,????E-Business Suite?????????,??????????????????????????,???????????????,??????????????????????????????,???EBS????,???????????????????????????????Note 167000.1???????????????????????,????????E-Business Suite?????????EBS 12.0.6?????,Oracle?????????????Oracle??,??adpatch????????????EBS??12.1.1???,????????????? Oracle E-Business Suite ?????????: ???? —???????????????????????? ?????? —?????Oracle ???????? ????????—?????????????????????,???? ???????,????????EBS Period Close??,???????SQLGL Period Closing???????????????????????????General Ledger ???????? ?? Select Application??????????????,????? Period Close??????? Period Close ?? Period Closing??????????Execute?? ???????Submit ?? ?? Refresh ??,??????? “In Progress” ?? “Completed” ??View Report?????????? ??????????,????????????????????,?????,?????????????????,?????Oracle???????????,??????????????,????????????????? ??,??????? ??,???????? ??????,??E-Business Suite ???? Diagnostic Tools Community?????????????????,????????Oracle????????? Oracle? Period Close ???,????E-Business Suite?????,????????,?????????????????? Period Close???,??????????,???????????????????,?????????,???????????????,???????????????????,???????,??????????????????????? ???? E-Business Suite Diagnostics Period / Year End Close [ID 402237.1] ??????Closing Period????????????????????????????????Closing Period ??,???????????????????????EBS???????,???E-Business Suite Diagnostics Overview [ID 342459.1].

    Read the article

  • Whys is System process listening on Port 80?

    - by Seth Spearman
    I am running Windows 7 RC1. I have multiple issues getting IIS to work on my system and today when I installed a new application and I tried to load it using http:\localhost\MyApplication I get absolutely no errors and I get no page load. Just a pretty, white blank page. I did some digging and I found something about some other process listening on port 80 so I did a scan using netstat -aon | findstr 0.0:80 and discovered that PID 4 was listening on that port. PID 4 does not show in task manager so I fired up Process Explorer and it showed me that PID 4 is the System process. (Multiple google searches seems to indicate that System always uses PID 4). Since then I am basically stuck. I have no idea why System needs port 80 and what to do about it. If you google the following strings you will find two helpful Experts-Exchange articles at the top of the search results and you can read them for some helpful information. (If I gave the direct URL to the pages then Experts-Exchange would ask you to pay...but when you click on the results from a google search you can scroll all of the way to the bottom to read the exchanges.) Here are the google searches... "System Process is listening on port 80 (Vista)" "SYSTEM Process is listening on Port 80 and Preventing IIS Default Website from Running" The last entry from the first result showed how to do a trace of http.sys at the following URL: http://blogs.msdn.com/wndp/archive/2007/01/18/event-tracing-in-http-sys-part-1-capturing-a-trace.aspx Trace showed nothing useful. Any thoughts?

    Read the article

  • Throttle CPU Usage consumed by Process

    - by Brett Powell
    We run a game-server company where we basically have large amounts of customers sharing a single machine, and are just on their own instance of a Java Process (Minecraft) managed by our Web Control Panels. In the last few game updates released, we have noticed that many of the third-party plugins our customer's use have become poorly written and we are frequently seeing huge CPU increases from certain servers until we manually kill the process. Our Game Panel automatically restarts processes, so killing them is not really an issue. Our problem is that once once of these servers starts consuming 50%+ CPU Usage, it takes atleast 5 minutes to RDP into the machine, locate who it belongs to, shut it down and notify them. Are there any current solutions for Server 2008 which allow for the throttling of CPU usage or worst case, just auto kill a process stuck using that much? As Minecraft is essentially a single-threaded application, we have investigated using Affinity, although with the variations in our Packages and fluctuations in usage, this doesn't work well for us. Some option to throttle the maximum usage a process can use would be perfect, or at least the option to kill a process using that much. Thanks!

    Read the article

  • kill process but fail

    - by Tim
    Hi, I am running a bash script as a background job. The bash script calls a time-consuming executable. If I am not wrong, the running of the bash script is the parent process and the running of the executable is the child process. I now want to stop the whole running by killing the parent process which is the background job kill -9 $(jobs -p) The terminal shows that the running of the bash script is killed. But the running of the executable still hangs on the output of top. I just wonder how to also kill the child process? Thanks and regards!

    Read the article

  • Process limit for user in Linux

    - by BrainCore
    This is the standard question, "How do I set a process limit for a user account in Linux to prevent fork-bombing," with an additional twist. The running program originates as a root-owned Python process, which then setuids/setgids itself as a regular user. As far as I know, at this point, any limits set in /etc/security/limits.conf do not apply; the setuid-ed process may now fork bomb. Any ideas how to prevent this?

    Read the article

  • Process limit for user in Linux

    - by BrainCore
    This is the standard question, "How do I set a process limit for a user account in Linux to prevent fork-bombing," with an additional twist. The running program originates as a root-owned Python process, which then setuids/setgids itself as a regular user. As far as I know, at this point, any limits set in /etc/security/limits.conf do not apply; the setuid-ed process may now fork bomb. Any ideas how to prevent this?

    Read the article

  • "pull" process/job into the background

    - by Mustafa Ismail Mustafa
    I know of terminating a command with & and then moving it into the background by pressing Ctrl-Z and then bg [pid], and I also know of nohup. But say you started a process that turned out to take much longer than one expected, is there a way of pulling, so to speak, this process from another terminal screen into the background so that even if I log off from the server the process would continue?

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >