Search Results

Search found 3240 results on 130 pages for 'groupwise maximum'.

Page 40/130 | < Previous Page | 36 37 38 39 40 41 42 43 44 45 46 47  | Next Page >

  • how to optimize apache on web-server

    - by Prakash
    how can I optimize the server with following configuration. It takes too much time to load a page. IBM X3200 M3 Server - 1 Intel Xeon Processor with 4 GB Ram Below is my current configuration for apache: Start Servers: 5 (Default) Minimum Spare Servers: 10 Maximum Spare Servers: 20 Server Limit: 500 Max Clients: 500 Max Requests Per Child: 10000 (Default) Keep-Alive: On Keep-Alive Timeout: 5 Max Keep-Alive Requests: 100 Timeout: 200

    Read the article

  • Intel 82865G Graphics Controller - making it work in Windows 7

    - by abrams
    RE: Putting this out there in case someone else runs into this issue. The intel chipset is on-board. I discovered the reason for the crappy resolution in windows 7 was that the memory to share with the video card was set to 1MB in the BIOS. I changed this to 8MB (the maximum) and then the PC rebooted I was able to select a higher resolution. link|flag answered Aug 18 '09 at 5:53 Nick Kavadias Nick, Does this give Aero functionalty ?

    Read the article

  • How much memory do I need for innodb buffer pool?

    - by Shirko
    I read here that You need buffer pool a bit (say 10%) larger than your data (total size of Innodb TableSpaces) On the other hand I've read elswher that innodb_buffer_pool_size must be up to %80 of the memory. So I'm really confused how should I choose the best size for the pool. My database size is about 6GB and my total memory 64GB. Also I'm wondering if I increase the buffer pool size, I should shrink the number of maximum connections to make room for extra buffer, or these parameters are independent. Thanks

    Read the article

  • If a user is part of two TFS security groups, why do they (appear to) receive the lesser security of the two?

    - by Jedidja
    Given two TFS security groups Admins: Contains a set of Windows users Friends: Contains a Windows Security Group (which is also used as a mailing list) However, the people listed as admins are also part of the security group. It appears that when I lock down the Friends group to certain directories in TFS, the people in Admin also lose their privileges. Is there any way for users to receive the maximum security allowed between multiple groups they are included in? Or have I perhaps setup my TFS security groups incorrectly?

    Read the article

  • Website Reference about Server Placement

    - by Manuel Faux
    I have to do a student research project about "Server Placement in a Server Room". The paper should contain something like "place the racks about 3 meters away from any wall", "mind the maximum capacity load of the (false) floor" and other placement strategies. I have been searching for a while, but I did not find any reliable reference I can use in my work. Does anyone know some useful websites about server placement?

    Read the article

  • How much information can websites get about your browser/PC?

    - by Pickledegg
    I am trying to determine if the information shown on this website is the absolute maximum amount of information that a webserver can obtain from a web visitor. Does anyone know of any other sites that will be able to get more information from the user passively like this? I'm not talking about port-sniffing or any kind of interaction from the user, just the info that a server can get from a 'dumb' visit.

    Read the article

  • Apache php_ldap.dll error

    - by pluke
    I have apache with php 5.4 installed on a Windows 7 64bit machine. When I restart Apache I get the following: PHP Startup: Unable to load dynamic library 'c:/PHP54/ext\\php_ldap.dll' - %1 is not a valid Win32 application The file is present but LDAP doesn't work, any idea what I am doing wrong? php.ini has the following settings [ldap] ; Sets the maximum number of open links or -1 for unlimited. ldap.max_links = -1 ;extension=php_interbase.dll extension=php_ldap.dll extension=php_mbstring.dll

    Read the article

  • How to boost system sound output?

    - by infant programmer
    When I use Earphones, I feel that my system output is very low, I have set all the volume output to maximum in "control panel\Sounds and Audio devices", but still not satisfactory. May be my earphones output proportionality is lower. No problem with sub-woofer, I think its because of the amplifier. Is there any software to boost up system volume output to compensate ?

    Read the article

  • Exchange mailboxes are reaching their limit what can I do?

    - by Funky Si
    I have an exchange server which has mailboxes that are over 68GB, I understand that the maximum size of mailboxes is only 75GB which we expect to pass in the very near future. What can I do about this? I have another license of exchange that I could install and setup, is it possible to do this and move some mailboxes on to this and essentially give myself a 150GB limit spread across 2 servers? Another advice or helpful links would be great Thanks

    Read the article

  • Do busy smtp servers use long running tcp connections to exchange lot of mails?

    - by iamrohitbanga
    I had this idea from http://stackoverflow.com/questions/2813326/maximum-number-of-bytes-that-can-be-sent-on-a-tcp-connection is it possible that smtp servers like gmail and yahoo enter into some form of agreement to maintain a tcp connection between them so that lots of mails could be sent on the same tcp connection. it would be efficient as there would be heavy mail traffic between these mail servers.

    Read the article

  • Network speeds being report as 4x higher than actual in Windows 7 SP1

    - by Synetech
    Ever since installing Windows 7 SP1, I have noticed that all programs that display my network transfer rate have been exactly 4x higher than they actually are. For example, when I download something from a high-bandwidth web site or through torrents with lots of sources, the download rate indicated is is ~5MBps (~40Mbps) even though my Internet connection has a maximum of only 1.5MBps (12Mbps). It is the same situation with the upstream bandwidth: the connection maximum is 64KBps, but I’m seeing up to 256KBps. I have tried several different programs for monitoring bandwidth throughput and they all give the same results. I also tried different times and different days, and they always show the rate as being four times too high. My initial thought was that my ISP had increased the speeds (without my noticing), which they have done before. However, I checked my ISP’s site and they have not increased the speeds. Moreover, when I look at the speeds in the program actually doing the transfer (eg Chrome, µTorrent, etc.), the numbers are in line with the expected values at the same time that bandwidth monitoring programs are showing the high numbers. The only significant change (and pretty much the only change at all) that has occurred to my system since the change was the installation of SP1 for Windows 7. As such, it is my belief that some sort of change exists in SP1 whereby software that accesses the bandwidth via a specific API receives (erroneously?) high numbers while others that have access to the raw data continue to receive the correct values. I booted into Windows XP and downloaded some things via HTTP and torrent and in both cases, the numbers were as expected (like they were in Windows 7 before installing SP1). I then booted back into 7SP1 and once again, the numbers were four times higher than possible. Therefore it is definitely something in SP1 that has changed how local bandwidth is calculated/returned. There is definitely something wonky with Windows 7 SP1’s network speed calculation. I tried Googling this, but (for multiple reasons), have had a difficult time finding anything relevant. Has anybody else noticed this behavior? Does anybody know of any bugs or changes in SP1 that could account for it?

    Read the article

  • Configuring a monitor's constract/brightess/colours/etc

    - by DMA57361
    I have recently bought myself a new monitor, now I'd had my previous screen well over 5 years now so I'm looking at this one thinking the picture doesn't quite look right (not bad, just different). Rather than just wait until I'm used to the new picture I'd rather get it fine tuned, then get used to it - so I can reap the maximum benefit. So, can you please suggest reliable ways of configuring an LCD monitor's brightness/contrast/colour/etc to provide the optimum possibly quality image?

    Read the article

  • Automatic picture size adjustment

    - by CChriss
    Does anyone know of a free utility that allows you to paste into it a graphics file (any type would work for me, jpg, bmp, png, etc) and it will size the file to within a preset size boundary? For instance, if I preset it to resize files to be a maximum of 400 wide by 300 tall, and I paste in a file 500x500, it would shrink the file to fit within the 300 tall limit. Thanks.

    Read the article

  • Printing data in Excel ver 14.0 in a maxed cell

    - by Zppy
    I have set the cell to the maximum size (column width of 255 and row height of 409.5). In order to view all of the data in the cell, I have to use up/down arrows. I don't need to necessarily view all of the data in the cell at one time, however I do need it to print, and it's only printing what's viewable (not what you can scroll through).....any suggestions on how to get the entire cell to print? Thanks!

    Read the article

  • How it was detected if last ACK lost in TCP connection termination procedure?

    - by sonali
    In TCP Connection Termination, when client enters in TIME_WAIT state means the client waits for a period of time equal to double the maximum segment life (MSL) time, to ensure the ACK it sent was received. (I read above from a book computer networking by kurose and also given in following URL http://www.tcpipguide.com/free/t_TCPConnectionTermination-2.htm ) But how it was detected if last ACK(send by client as a response to server FIN) lost?

    Read the article

  • WPF Databinding- Not your fathers databinding Part 1-3

    - by Shervin Shakibi
    As Promised here is my advanced databinding presentation from South Florida Code camp and also Orlando Code camp. you can find the demo files here. http://ssccinc.com/wpfdatabinding.zip Here is a quick description of the first demos, there will be 2 other Blogposting in the next few days getting into more advance databinding topics.   Example00 Here we have 3 textboxes, The first textbox mySourceElement Second textbox has a binding to mySourceElement and Path= Text <Binding ElementName="mySourceElement" Path="Text"  />   Third textbox is also bound to the Text property but we use inline Binding <TextBlock Text="{Binding ElementName=mySourceElement,Path=Text }" Grid.Row="2" /> Here is the entire XAML     <Grid  >           <Grid.RowDefinitions >             <RowDefinition Height="*" />             <RowDefinition Height="*" />             <RowDefinition Height="*" />         </Grid.RowDefinitions>         <TextBox Name="mySourceElement" Grid.Row="0"                  TextChanged="mySourceElement_TextChanged">Hello Orlnado</TextBox>         <TextBlock Grid.Row="1">                        <TextBlock.Text>                 <Binding ElementName="mySourceElement" Path="Text"  />             </TextBlock.Text>         </TextBlock>         <TextBlock Text="{Binding ElementName=mySourceElement,Path=Text }" Grid.Row="2" />     </Grid> </Window> Example01 we have a slider control, then we have two textboxes bound to the value property of the slider. one has its text property bound, the second has its fontsize property bound. <Grid>      <Grid.RowDefinitions >          <RowDefinition Height="40px" />          <RowDefinition Height="40px" />          <RowDefinition Height="*" />      </Grid.RowDefinitions>      <Slider Name="fontSizeSlider" Minimum="5" Maximum="100"              Value="10" Grid.Row="0" />      <TextBox Name="SizeTextBox"                    Text="{Binding ElementName=fontSizeSlider, Path=Value}" Grid.Row="1"/>      <TextBlock Text="Example 01"                 FontSize="{Binding ElementName=SizeTextBox,  Path=Text}"  Grid.Row="2"/> </Grid> Example02 very much like the previous example but it also has a font dropdown <Grid>      <Grid.RowDefinitions >          <RowDefinition Height="20px" />          <RowDefinition Height="40px" />          <RowDefinition Height="40px" />          <RowDefinition Height="*" />      </Grid.RowDefinitions>      <ComboBox Name="FontNameList" SelectedIndex="0" Grid.Row="0">          <ComboBoxItem Content="Arial" />          <ComboBoxItem Content="Calibri" />          <ComboBoxItem Content="Times New Roman" />          <ComboBoxItem Content="Verdana" />      </ComboBox>      <Slider Name="fontSizeSlider" Minimum="5" Maximum="100" Value="10" Grid.Row="1" />      <TextBox Name="SizeTextBox"      Text="{Binding ElementName=fontSizeSlider, Path=Value}" Grid.Row="2"/>      <TextBlock Text="Example 01" FontFamily="{Binding ElementName=FontNameList, Path=Text}"                 FontSize="{Binding ElementName=SizeTextBox,  Path=Text}"  Grid.Row="3"/> </Grid> Example03 In this example we bind to an object Employee.cs Notice we added a directive to our xaml which is clr-namespace and the namespace for our employee Class xmlns:local="clr-namespace:Example03" In Our windows Resources we create an instance of our object <Window.Resources>     <local:Employee x:Key="MyEmployee" EmployeeNumber="145"                     FirstName="John"                     LastName="Doe"                     Department="Product Development"                     Title="QA Manager" /> </Window.Resources> then we bind our container to the that instance of the data <Grid DataContext="{StaticResource MyEmployee}">         <Grid.RowDefinitions>             <RowDefinition Height="*" />             <RowDefinition Height="*" />             <RowDefinition Height="*" />             <RowDefinition Height="*" />             <RowDefinition Height="*" />         </Grid.RowDefinitions>         <Grid.ColumnDefinitions >             <ColumnDefinition Width="130px" />             <ColumnDefinition Width="178*" />         </Grid.ColumnDefinitions>     </Grid> and Finally we have textboxes that will bind to that textbox         <Label Grid.Row="0" Grid.Column="0">Employee Number</Label>         <TextBox Grid.Row="0" Grid.Column="1" Text="{Binding Path=EmployeeNumber}"></TextBox>         <Label Grid.Row="1" Grid.Column="0">First Name</Label>         <TextBox Grid.Row="1" Grid.Column="1" Text="{Binding Path=FirstName}"></TextBox>         <Label Grid.Row="2" Grid.Column="0">Last Name</Label>         <TextBox Grid.Row="2" Grid.Column="1" Text="{Binding Path=LastName}" />         <Label Grid.Row="3" Grid.Column="0">Title</Label>         <TextBox Grid.Row="3" Grid.Column="1" Text="{Binding Path=Title}"></TextBox>         <Label Grid.Row="4" Grid.Column="0">Department</Label>         <TextBox Grid.Row="4" Grid.Column="1" Text="{Binding Path=Department}" />

    Read the article

  • WebLogic Server Performance and Tuning: Part I - Tuning JVM

    - by Gokhan Gungor
    Each WebLogic Server instance runs in its own dedicated Java Virtual Machine (JVM) which is their runtime environment. Every Admin Server in any domain executes within a JVM. The same also applies for Managed Servers. WebLogic Server can be used for a wide variety of applications and services which uses the same runtime environment and resources. Oracle WebLogic ships with 2 different JVM, HotSpot and JRocket but you can choose which JVM you want to use. JVM is designed to optimize itself however it also provides some startup options to make small changes. There are default values for its memory and garbage collection. In real world, you will not want to stick with the default values provided by the JVM rather want to customize these values based on your applications which can produce large gains in performance by making small changes with the JVM parameters. We can tell the garbage collector how to delete garbage and we can also tell JVM how much space to allocate for each generation (of java Objects) or for heap. Remember during the garbage collection no other process is executed within the JVM or runtime, which is called STOP THE WORLD which can affect the overall throughput. Each JVM has its own memory segment called Heap Memory which is the storage for java Objects. These objects can be grouped based on their age like young generation (recently created objects) or old generation (surviving objects that have lived to some extent), etc. A java object is considered garbage when it can no longer be reached from anywhere in the running program. Each generation has its own memory segment within the heap. When this segment gets full, garbage collector deletes all the objects that are marked as garbage to create space. When the old generation space gets full, the JVM performs a major collection to remove the unused objects and reclaim their space. A major garbage collect takes a significant amount of time and can affect system performance. When we create a managed server either on the same machine or on remote machine it gets its initial startup parameters from $DOMAIN_HOME/bin/setDomainEnv.sh/cmd file. By default two parameters are set:     Xms: The initial heapsize     Xmx: The max heapsize Try to set equal initial and max heapsize. The startup time can be a little longer but for long running applications it will provide a better performance. When we set -Xms512m -Xmx1024m, the physical heap size will be 512m. This means that there are pages of memory (in the state of the 512m) that the JVM does not explicitly control. It will be controlled by OS which could be reserve for the other tasks. In this case, it is an advantage if the JVM claims the entire memory at once and try not to spend time to extend when more memory is needed. Also you can use -XX:MaxPermSize (Maximum size of the permanent generation) option for Sun JVM. You should adjust the size accordingly if your application dynamically load and unload a lot of classes in order to optimize the performance. You can set the JVM options/heap size from the following places:     Through the Admin console, in the Server start tab     In the startManagedWeblogic script for the managed servers     $DOMAIN_HOME/bin/startManagedWebLogic.sh/cmd     JAVA_OPTIONS="-Xms1024m -Xmx1024m" ${JAVA_OPTIONS}     In the setDomainEnv script for the managed servers and admin server (domain wide)     USER_MEM_ARGS="-Xms1024m -Xmx1024m" When there is free memory available in the heap but it is too fragmented and not contiguously located to store the object or when there is actually insufficient memory we can get java.lang.OutOfMemoryError. We should create Thread Dump and analyze if that is possible in case of such error. The second option we can use to produce higher throughput is to garbage collection. We can roughly divide GC algorithms into 2 categories: parallel and concurrent. Parallel GC stops the execution of all the application and performs the full GC, this generally provides better throughput but also high latency using all the CPU resources during GC. Concurrent GC on the other hand, produces low latency but also low throughput since it performs GC while application executes. The JRockit JVM provides some useful command-line parameters that to control of its GC scheme like -XgcPrio command-line parameter which takes the following options; XgcPrio:pausetime (To minimize latency, parallel GC) XgcPrio:throughput (To minimize throughput, concurrent GC ) XgcPrio:deterministic (To guarantee maximum pause time, for real time systems) Sun JVM has similar parameters (like  -XX:UseParallelGC or -XX:+UseConcMarkSweepGC) to control its GC scheme. We can add -verbosegc -XX:+PrintGCDetails to monitor indications of a problem with garbage collection. Try configuring JVM’s of all managed servers to execute in -server mode to ensure that it is optimized for a server-side production environment.

    Read the article

  • SQL SERVER – Service Broker and CAP_CPU_PERCENT – Limiting SQL Server Instances to CPU Usage

    - by pinaldave
    I have mentioned several times on this blog that the best part of blogging is the questions I receive from readers. They are often very interesting. The questions from readers give me a good idea what other readers might be thinking as well. After reading my earlier article Simple Example to Configure Resource Governor – Introduction to Resource Governor – I received an email from a reader and we exchanged a few emails. After exchanging emails we both figured out what is going on. It was indeed interesting and reader suggested to that I should blog about it.  I asked for permission to publish his name but he does not like the attention so we will just call him Jeff. I have converted our emails into chat for easy consumption. Jeff: Your script does not work at all. I think either there is a bug in SQL Server. Pinal: Would you please explain in detail? Jeff: Your code does not limit the CPU usage? Pinal: How did you measure it? Jeff: Well, we have third party tools for it but let us say I have limited the resources for Reporting Services and used your script described in your blog. After that I ran only reporting service workload the CPU is still used more than 100% and it is not limited to 30% as described in your script. Clearly something is wrong somewhere. Pinal: Did you say you ONLY ran reporting server load? Jeff: Yeah, to validate I ran ONLY reporting server load and CPU did not throttle at 30% as per your script. Pinal: Oh! I get it here is the answer - CAP_CPU_PERCENT = 30. Use it. Jeff: What is that, I think your earlier script says it will throttle the Reporting Service workload and Application/OLTP workload and balance it. Pinal: Exactly, that is correct. Jeff: You need to write more in email buddy! Just like your blogs, your answers do not make sense! No Offense! Pinal: Hmm…feedback well taken. Let me try again. In SQL Server 2012 there are a few enhancements with regards to SQL Server Resource Governor. One of the enhancement is how the resources are allocated. Let me explain you with examples. Configuration: [Read Earlier Post] Reporting Workload: MIN_CPU_PERCENT=0, MAX_CPU_PERCENT=30 Application/OLTP Workload: MIN_CPU_PERCENT=50, MAX_CPU_PERCENT=100 Example 1: If there is only Reporting Workload on the server: SQL Server will not limit usage of CPU to only 30% workload but SQL Server instance will use all available CPU (if needed). In another word in this scenario it will use more than 30% CPU. Example 2: If there is Reproting Workload and heavy Application/OLTP workload: SQL Server will allocate a maximum of 30% CPU resources to Reporting Workload and allocate remaining resources to heavy application/OLTP workload. The reason for this enhancement is for better utilization of the resources. Let us think, if there is only single workload, which we have limited to max CPU usage to 30%. The other unused available CPU resources is now wasted. In this situation SQL Server allows the workload to use more than 30% resources leading to overall improved/optimized performance. However, in the case of multiple workload where lots of resources are needed the limits specified in MAX_CPU_PERCENT are acknowledged. Example 3: If there is a situation where the max CPU workload has to be enforced: This is a very interesting scenario, in the case when the max CPU workload has to be enforced irrespective of the workload and enhanced algorithm, the keyword CAP_CPU_PERCENT is essential. It specifies a hard cap on the CPU bandwidth that all requests in the resource pool will receive. It will never let CPU usage for reporting workload to go over 30% in our case. You can use the key word as follows: -- Creating Resource Pool for Report Server CREATE RESOURCE POOL ReportServerPool WITH ( MIN_CPU_PERCENT=0, MAX_CPU_PERCENT=30, CAP_CPU_PERCENT=40, MIN_MEMORY_PERCENT=0, MAX_MEMORY_PERCENT=30) GO Notice that there is MAX_CPU_PERCENT=30 and CAP_CPU_PERCENT=40, what it means is that when SQL Server Instance is under heavy load under different workload it will use the maximum CPU at 30%. However, when the SQL Server instance is not under workload it will go over the 30% limit. However, as CAP_CPU_PERCENT is set to 40, it will not go over 40% in any case by limiting the usage of CPU. CAP_CPU_PERCENT puts a hard limit on the resources usage by workload. Jeff: Nice Pinal, you should blog about it. [A day passes by] Pinal: Jeff, it is done! Click here to read it. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology Tagged: Service Broker

    Read the article

  • Azure &ndash; Part 6 &ndash; Blob Storage Service

    - by Shaun
    When migrate your application onto the Azure one of the biggest concern would be the external files. In the original way we understood and ensure which machine and folder our application (website or web service) is located in. So that we can use the MapPath or some other methods to read and write the external files for example the images, text files or the xml files, etc. But things have been changed when we deploy them on Azure. Azure is not a server, or a single machine, it’s a set of virtual server machine running under the Azure OS. And even worse, your application might be moved between thses machines. So it’s impossible to read or write the external files on Azure. In order to resolve this issue the Windows Azure provides another storage serviec – Blob, for us. Different to the table service, the blob serivce is to be used to store text and binary data rather than the structured data. It provides two types of blobs: Block Blobs and Page Blobs. Block Blobs are optimized for streaming. They are comprised of blocks, each of which is identified by a block ID and each block can be a maximum of 4 MB in size. Page Blobs are are optimized for random read/write operations and provide the ability to write to a range of bytes in a blob. They are a collection of pages. The maximum size for a page blob is 1 TB.   In the managed library the Azure SDK allows us to communicate with the blobs through these classes CloudBlobClient, CloudBlobContainer, CloudBlockBlob and the CloudPageBlob. Similar with the table service managed library, the CloudBlobClient allows us to reach the blob service by passing our storage account information and also responsible for creating the blob container is not exist. Then from the CloudBlobContainer we can save or load the block blobs and page blobs into the CloudBlockBlob and the CloudPageBlob classes.   Let’s improve our exmaple in the previous posts – add a service method allows the user to upload the logo image. In the server side I created a method name UploadLogo with 2 parameters: email and image. Then I created the storage account from the config file. I also add the validation to ensure that the email passed in is valid. 1: var storageAccount = CloudStorageAccount.FromConfigurationSetting("DataConnectionString"); 2: var accountContext = new DynamicDataContext<Account>(storageAccount); 3:  4: // validation 5: var accountNumber = accountContext.Load() 6: .Where(a => a.Email == email) 7: .ToList() 8: .Count; 9: if (accountNumber <= 0) 10: { 11: throw new ApplicationException(string.Format("Cannot find the account with the email {0}.", email)); 12: } Then there are three steps for saving the image into the blob service. First alike the table service I created the container with a unique name and create it if it’s not exist. 1: // create the blob container for account logos if not exist 2: CloudBlobClient blobStorage = storageAccount.CreateCloudBlobClient(); 3: CloudBlobContainer container = blobStorage.GetContainerReference("account-logo"); 4: container.CreateIfNotExist(); Then, since in this example I will just send the blob access URL back to the client so I need to open the read permission on that container. 1: // configure blob container for public access 2: BlobContainerPermissions permissions = container.GetPermissions(); 3: permissions.PublicAccess = BlobContainerPublicAccessType.Container; 4: container.SetPermissions(permissions); And at the end I combine the blob resource name from the input file name and Guid, and then save it to the block blob by using the UploadByteArray method. Finally I returned the URL of this blob back to the client side. 1: // save the blob into the blob service 2: string uniqueBlobName = string.Format("{0}_{1}.jpg", email, Guid.NewGuid().ToString()); 3: CloudBlockBlob blob = container.GetBlockBlobReference(uniqueBlobName); 4: blob.UploadByteArray(image); 5:  6: return blob.Uri.ToString(); Let’s update a bit on the client side application and see the result. Here I just use my simple console application to let the user input the email and the file name of the image. If it’s OK it will show the URL of the blob on the server side so that we can see it through the web browser. Then we can see the logo I’ve just uploaded through the URL here. You may notice that the blob URL was based on the container name and the blob unique name. In the document of the Azure SDK there’s a page for the rule of naming them, but I think the simple rule would be – they must be valid as an URL address. So that you cannot name the container with dot or slash as it will break the ADO.Data Service routing rule. For exmaple if you named the blob container as Account.Logo then it will throw an exception says 400 Bad Request.   Summary In this short entity I covered the simple usage of the blob service to save the images onto Azure. Since the Azure platform does not support the file system we have to migrate our code for reading/writing files to the blob service before deploy it to Azure. In order to reducing this effort Microsoft provided a new approch named Drive, which allows us read and write the NTFS files just likes what we did before. It’s built up on the blob serivce but more properly for files accessing. I will discuss more about it in the next post.   Hope this helps, Shaun All documents and related graphics, codes are provided "AS IS" without warranty of any kind. Copyright © Shaun Ziyan Xu. This work is licensed under the Creative Commons License.

    Read the article

  • How to Calibrate HP Laptop Battery

    - by batteryfast
    Calibrating the HP Laptop Battery This document pertains to HP Notebook PCs with Windows 7 and Vista. Calibrating the laptop battery Calibrating the battery means recharging the battery to its maximum capacity and resetting the battery gauge to display the level of charge accurately. The Windows system tray battery meter may not correctly display the battery charge level when a notebook is new or has not been used for a long period of time. If the battery gauge becomes inaccurate, use one of the methods below to calibrate the battery gauge reading. Calibrate the battery while PC is in use A calibration cycle requires that the battery be completely charged and then completely discharged. During the calibration cycle, the power management properties must be disabled to allow the battery to completely discharge.

    Read the article

  • Unlock the Full Value of Oracle CRM On Demand

    - by charles.knapp
    Register for this live Oracle CRM On Demand Virtual Community Session! Oracle CRM On Demand delivers the most complete On Demand CRM available anywhere. But how can you ensure you are getting maximum value from the many powerful features that Oracle CRM On Demand offers? Join our interactive Oracle CRM On Demand Virtual Community Session on Tuesday, January 11, 2011 from 10.00-11 a.m. PT / 1 p.m.-2 p.m. ET to get expert advice and discuss the best ways to unlock the full potential of Oracle CRM Demand with Mike Lairson, author of 'Oracle CRM On Demand Reporting'. Book OfferSend your Oracle CRM On Demand configuration ideas before the Webcast to [email protected] and you could win a free copy of 'Oracle CRM On Demand Reporting' by Mike Lairson. Learn more and register now!

    Read the article

  • ISO Files to USB &ndash; The Cheap and Easy Way

    - by RonGarlit
    (DISCLAIMER: Yes there are lots of more elegant ISO software beside the free Microsoft one I’m about to show. But free is free and it has been tested and works for me for making advance bootable USB drives. That is another story. Look up Windows 8 Developer Preview for that one on BING.) For those of use that work with new technology all the time we accumulate a lot of ISO files and have to burn them to CD/DVD’s quite often. But we now have machines without burner in the corporate environment. We have personally Netbooks and light wait highly mobile laptops that do not have DVD burner. USB ports are all the rage and now we have USB 3.0 which is way faster than the 2.0 we are used to. Just looking at the technology, space saving and the cost issues alone is a reason to buy these answer to the DVD’s. So what is special about USB 2.0 and USB 3.0? USB 2 has a maximum speed of 480 Mbps... (That is Megabits per SECOND!!) Now look at the storage that we have with USB thumb drives that are now up to 64 GB in size, cell phone and PDAs that have a lots of internal storage built in well above the 16 Gig range. At the MAX USB 2.0 speed of 480 Mbps a full transfer of data in between devices can take a long time. Time is money right. Every back up a iPhone? Don’t get me started. So at least the engineers have been planning ahead with USB 3.0 which offers a maximum transfer speed of 4.8 Gbps... (That is Giga bits per SECOND!!) That speed is almost 10 times faster than USB 2.0 …. We don’t need to do the math on that one do we? But for now I'm thrilled with USB 2.0 and the fact I can get these little 4 Gig USB drives for $4.00 each at Staples on sale. Well that is a no brainer don’t you think. But what can you do with them to replace that DVD. Simply and cheaply put………. THIS! First let’s get an ISO file like the Visual Studio 2010 Ultimate DVD ISO from MSDN to demonstrate with. I develop on several computers so this is a good choice for me. So we downloaded the ISO file and put it in a folder somewhere like this. Next we go download to the Windows 7 USB/DVD Download Tool site and read about the tool. http://www.microsoftstore.com/store/msstore/html/pbPage.Help_Win7_usbdvd_dwnTool And click this like to get the tool and install it. Once it is installed you go to the Start, Programs menu, Windows 7 USB DVD Download Tool folder. And then click the tool to open it up. As you will see it is a sweet, simple tool that was originally designed to put the ISO for Windows 7 which is designed to be bootable on a USB or DVD for us geeks to play with. It is now being used for the Windows 8 Developer Preview by many developers for that for the same purpose it was built for in the past. But for now we will use it to put a NON Bootable ISO on a USB. Hey it does the job and I’m reusing a left over program. Why buy the fancy one or a free trial and clutter up my machine. We will click the BROWSE button and navigate to where we put our ISO file we want to put on the USB drive. Obviously we are going to click NEXT and continue to select a USB Device (you can guess what the DVD button is for). Next we select the USB that we have plugged into one of our laptops USB ports. Then we click the BEGIN COPYING button and the first thing the program does is format our USB drive. Then it starts copying out files out of the ISO and constructing the USB as if it was a DVD. So now that the files are copying to the drive I’m going to warn you. We will error out here. This program was design for bootable ISO’s of which this one is NOT. No problem because what fails it the writing of the bootable data to the drive that isn’t there. No biggie…. Forget the STARTOVER button is even there and click the dialog’s CLOSE button and exit the program. Now go to Windows Explorer and navigate to the USB Device. You can now access everything and even add stuff to the drive. But for me I want to keep this drive for one purpose and that is to install VS2010 on various machines. So the only stuff I’ll add to this is a folder of notes on things on visual studio that I might want to put on other machines I’m installing VS2010 on to. So that is it. Have a nice day! The Ron

    Read the article

  • help with fixing fwts errors log

    - by jasmines
    Here is an extract of results.log: MTRR validation. Test 1 of 3: Validate the kernel MTRR IOMEM setup. FAILED [MEDIUM] MTRRIncorrectAttr: Test 1, Memory range 0xc0000000 to 0xdfffffff (PCI Bus 0000:00) has incorrect attribute Write-Combining. FAILED [MEDIUM] MTRRIncorrectAttr: Test 1, Memory range 0xfee01000 to 0xffffffff (PCI Bus 0000:00) has incorrect attribute Write-Protect. ==================================================================================================== Test 1 of 1: Kernel log error check. Kernel message: [ 0.208079] [Firmware Bug]: ACPI: BIOS _OSI(Linux) query ignored ADVICE: This is not exactly a failure mode but a warning from the kernel. The _OSI() method has implemented a match to the 'Linux' query in the DSDT and this is redundant because the ACPI driver matches onto the Windows _OSI strings by default. FAILED [HIGH] KlogACPIErrorMethodExecutionParse: Test 1, HIGH Kernel message: [ 3.512783] ACPI Error : Method parse/execution failed [\_SB_.PCI0.GFX0._DOD] (Node f7425858), AE_AML_PACKAGE_LIMIT (20110623/psparse-536) ADVICE: This is a bug picked up by the kernel, but as yet, the firmware test suite has no diagnostic advice for this particular problem. Found 1 unique errors in kernel log. ==================================================================================================== Check if system is using latest microcode. ---------------------------------------------------------------------------------------------------- Cannot read microcode file /usr/share/misc/intel-microcode.dat. Aborted test, initialisation failed. ==================================================================================================== MSR register tests. FAILED [MEDIUM] MSRCPUsInconsistent: Test 1, MSR SYSENTER_ESP (0x175) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0xffffffffffffffff). MSR CPU 0 -> 0xf7bb9c40 vs CPU 1 -> 0xf7bc7c40 FAILED [MEDIUM] MSRCPUsInconsistent: Test 1, MSR MISC_ENABLE (0x1a0) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0x400c51889). MSR CPU 0 -> 0x850088 vs CPU 1 -> 0x850089 ==================================================================================================== Checks firmware has set PCI Express MaxReadReq to a higher value on non-motherboard devices. ---------------------------------------------------------------------------------------------------- Test 1 of 1: Check firmware settings MaxReadReq for PCI Express devices. MaxReadReq for pci://00:00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) is low (128) [Audio device]. MaxReadReq for pci://00:02:00.0 Network controller: Intel Corporation PRO/Wireless 5100 AGN [Shiloh] Network Connection is low (128) [Network controller]. FAILED [LOW] LowMaxReadReq: Test 1, 2 devices have low MaxReadReq settings. Firmware may have configured these too low. ADVICE: The MaxReadRequest size is set too low and will affect performance. It will provide excellent bus sharing at the cost of bus data transfer rates. Although not a critical issue, it may be worth considering setting the MaxReadRequest size to 256 or 512 to increase throughput on the PCI Express bus. Some drivers (for example the Brocade Fibre Channel driver) allow one to override the firmware settings. Where possible, this BIOS configuration setting is worth increasing it a little more for better performance at a small reduction of bus sharing. ==================================================================================================== PCIe ASPM check. ---------------------------------------------------------------------------------------------------- Test 1 of 2: PCIe ASPM ACPI test. PCIE ASPM is not controlled by Linux kernel. ADVICE: BIOS reports that Linux kernel should not modify ASPM settings that BIOS configured. It can be intentional because hardware vendors identified some capability bugs between the motherboard and the add-on cards. Test 2 of 2: PCIe ASPM registers test. WARNING: Test 2, RP 00h:1Ch.01h L0s not enabled. WARNING: Test 2, RP 00h:1Ch.01h L1 not enabled. WARNING: Test 2, Device 02h:00h.00h L0s not enabled. WARNING: Test 2, Device 02h:00h.00h L1 not enabled. PASSED: Test 2, PCIE aspm setting matched was matched. WARNING: Test 2, RP 00h:1Ch.05h L0s not enabled. WARNING: Test 2, RP 00h:1Ch.05h L1 not enabled. WARNING: Test 2, Device 85h:00h.00h L0s not enabled. WARNING: Test 2, Device 85h:00h.00h L1 not enabled. PASSED: Test 2, PCIE aspm setting matched was matched. ==================================================================================================== Extract and analyse Windows Management Instrumentation (WMI). Test 1 of 2: Check Windows Management Instrumentation in DSDT Found WMI Method WMAA with GUID: 5FB7F034-2C63-45E9-BE91-3D44E2C707E4, Instance 0x01 Found WMI Event, Notifier ID: 0x80, GUID: 95F24279-4D7B-4334-9387-ACCDC67EF61C, Instance 0x01 PASSED: Test 1, GUID 95F24279-4D7B-4334-9387-ACCDC67EF61C is handled by driver hp-wmi (Vendor: HP). Found WMI Event, Notifier ID: 0xa0, GUID: 2B814318-4BE8-4707-9D84-A190A859B5D0, Instance 0x01 FAILED [MEDIUM] WMIUnknownGUID: Test 1, GUID 2B814318-4BE8-4707-9D84-A190A859B5D0 is unknown to the kernel, a driver may need to be implemented for this GUID. ADVICE: A WMI driver probably needs to be written for this event. It can checked for using: wmi_has_guid("2B814318-4BE8-4707-9D84-A190A859B5D0"). One can install a notify handler using wmi_install_notify_handler("2B814318-4BE8-4707-9D84-A190A859B5D0", handler, NULL). http://lwn.net/Articles/391230 describes how to write an appropriate driver. Found WMI Object, Object ID AB, GUID: 05901221-D566-11D1-B2F0-00A0C9062910, Instance 0x01, Flags: 00 Found WMI Method WMBA with GUID: 1F4C91EB-DC5C-460B-951D-C7CB9B4B8D5E, Instance 0x01 Found WMI Object, Object ID BC, GUID: 2D114B49-2DFB-4130-B8FE-4A3C09E75133, Instance 0x7f, Flags: 00 Found WMI Object, Object ID BD, GUID: 988D08E3-68F4-4C35-AF3E-6A1B8106F83C, Instance 0x19, Flags: 00 Found WMI Object, Object ID BE, GUID: 14EA9746-CE1F-4098-A0E0-7045CB4DA745, Instance 0x01, Flags: 00 Found WMI Object, Object ID BF, GUID: 322F2028-0F84-4901-988E-015176049E2D, Instance 0x01, Flags: 00 Found WMI Object, Object ID BG, GUID: 8232DE3D-663D-4327-A8F4-E293ADB9BF05, Instance 0x01, Flags: 00 Found WMI Object, Object ID BH, GUID: 8F1F6436-9F42-42C8-BADC-0E9424F20C9A, Instance 0x00, Flags: 00 Found WMI Object, Object ID BI, GUID: 8F1F6435-9F42-42C8-BADC-0E9424F20C9A, Instance 0x00, Flags: 00 Found WMI Method WMAC with GUID: 7391A661-223A-47DB-A77A-7BE84C60822D, Instance 0x01 Found WMI Object, Object ID BJ, GUID: DF4E63B6-3BBC-4858-9737-C74F82F821F3, Instance 0x05, Flags: 00 ==================================================================================================== Disassemble DSDT to check for _OSI("Linux"). ---------------------------------------------------------------------------------------------------- Test 1 of 1: Disassemble DSDT to check for _OSI("Linux"). This is not strictly a failure mode, it just alerts one that this has been defined in the DSDT and probably should be avoided since the Linux ACPI driver matches onto the Windows _OSI strings { If (_OSI ("Linux")) { Store (0x03E8, OSYS) } If (_OSI ("Windows 2001")) { Store (0x07D1, OSYS) } If (_OSI ("Windows 2001 SP1")) { Store (0x07D1, OSYS) } If (_OSI ("Windows 2001 SP2")) { Store (0x07D2, OSYS) } If (_OSI ("Windows 2006")) { Store (0x07D6, OSYS) } If (LAnd (MPEN, LEqual (OSYS, 0x07D1))) { TRAP (0x01, 0x48) } TRAP (0x03, 0x35) } WARNING: Test 1, DSDT implements a deprecated _OSI("Linux") test. ==================================================================================================== 0 passed, 0 failed, 1 warnings, 0 aborted, 0 skipped, 0 info only. ==================================================================================================== ACPI DSDT Method Semantic Tests. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP Failed to install global event handler. Test 22 of 93: Check _PSR (Power Source). ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 22, Detected an infinite loop when evaluating method '\_SB_.AC__._PSR'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 22, \_SB_.AC__._PSR correctly acquired and released locks 16 times. Test 35 of 93: Check _TMP (Thermal Zone Current Temp). ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.DTSZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.DTSZ._TMP correctly acquired and released locks 14 times. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.CPUZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.CPUZ._TMP correctly acquired and released locks 10 times. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.SKNZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.SKNZ._TMP correctly acquired and released locks 10 times. PASSED: Test 35, _TMP correctly returned sane looking value 0x00000b4c (289.2 degrees K) PASSED: Test 35, \_TZ_.BATZ._TMP correctly acquired and released locks 9 times. PASSED: Test 35, _TMP correctly returned sane looking value 0x00000aac (273.2 degrees K) PASSED: Test 35, \_TZ_.FDTZ._TMP correctly acquired and released locks 7 times. Test 46 of 93: Check _DIS (Disable). FAILED [MEDIUM] MethodShouldReturnNothing: Test 46, \_SB_.PCI0.LPCB.SIO_.COM1._DIS returned values, but was expected to return nothing. Object returned: INTEGER: 0x00000000 ADVICE: This probably won't cause any errors, but it should be fixed as the AML code is not conforming to the expected behaviour as described in the ACPI specification. FAILED [MEDIUM] MethodShouldReturnNothing: Test 46, \_SB_.PCI0.LPCB.SIO_.LPT0._DIS returned values, but was expected to return nothing. Object returned: INTEGER: 0x00000000 ADVICE: This probably won't cause any errors, but it should be fixed as the AML code is not conforming to the expected behaviour as described in the ACPI specification. Test 61 of 93: Check _WAK (System Wake). Test _WAK(1) System Wake, State S1. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(2) System Wake, State S2. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(3) System Wake, State S3. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(4) System Wake, State S4. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(5) System Wake, State S5. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test 87 of 93: Check _BCL (Query List of Brightness Control Levels Supported). Package has 2 elements: 00: INTEGER: 0x00000000 01: INTEGER: 0x00000000 FAILED [MEDIUM] Method_BCLElementCount: Test 87, Method _BCL should return a package of more than 2 integers, got just 2. Test 88 of 93: Check _BCM (Set Brightness Level). ACPICA Exception AE_AML_PACKAGE_LIMIT during execution of method _BCM FAILED [CRITICAL] AEAMLPackgeLimit: Test 88, Detected error 'Package limit' when evaluating '\_SB_.PCI0.GFX0.DD02._BCM'. ==================================================================================================== ACPI table settings sanity checks. ---------------------------------------------------------------------------------------------------- Test 1 of 1: Check ACPI tables. PASSED: Test 1, Table APIC passed. Table ECDT not present to check. FAILED [MEDIUM] FADT32And64BothDefined: Test 1, FADT 32 bit FIRMWARE_CONTROL is non-zero, and X_FIRMWARE_CONTROL is also non-zero. Section 5.2.9 of the ACPI specification states that if the FIRMWARE_CONTROL is non-zero then X_FIRMWARE_CONTROL must be set to zero. ADVICE: The FADT FIRMWARE_CTRL is a 32 bit pointer that points to the physical memory address of the Firmware ACPI Control Structure (FACS). There is also an extended 64 bit version of this, the X_FIRMWARE_CTRL pointer that also can point to the FACS. Section 5.2.9 of the ACPI specification states that if the X_FIRMWARE_CTRL field contains a non zero value then the FIRMWARE_CTRL field *must* be zero. This error is also detected by the Linux kernel. If FIRMWARE_CTRL and X_FIRMWARE_CTRL are defined, then the kernel just uses the 64 bit version of the pointer. PASSED: Test 1, Table HPET passed. PASSED: Test 1, Table MCFG passed. PASSED: Test 1, Table RSDT passed. PASSED: Test 1, Table RSDP passed. Table SBST not present to check. PASSED: Test 1, Table XSDT passed. ==================================================================================================== Re-assemble DSDT and find syntax errors and warnings. ---------------------------------------------------------------------------------------------------- Test 1 of 2: Disassemble and reassemble DSDT FAILED [HIGH] AMLAssemblerError4043: Test 1, Assembler error in line 2261 Line | AML source ---------------------------------------------------------------------------------------------------- 02258| 0x00000000, // Range Minimum 02259| 0xFEDFFFFF, // Range Maximum 02260| 0x00000000, // Translation Offset 02261| 0x00000000, // Length | ^ | error 4043: Invalid combination of Length and Min/Max fixed flags 02262| ,, _Y0E, AddressRangeMemory, TypeStatic) 02263| DWordMemory (ResourceProducer, PosDecode, MinFixed, MaxFixed, Cacheable, ReadWrite, 02264| 0x00000000, // Granularity ==================================================================================================== ADVICE: (for error #4043): This occurs if the length is zero and just one of the resource MIF/MAF flags are set, or the length is non-zero and resource MIF/MAF flags are both set. These are illegal combinations and need to be fixed. See section 6.4.3.5 Address Space Resource Descriptors of version 4.0a of the ACPI specification for more details. FAILED [HIGH] AMLAssemblerError4050: Test 1, Assembler error in line 2268 Line | AML source ---------------------------------------------------------------------------------------------------- 02265| 0xFEE01000, // Range Minimum 02266| 0xFFFFFFFF, // Range Maximum 02267| 0x00000000, // Translation Offset 02268| 0x011FEFFF, // Length | ^ | error 4050: Length is not equal to fixed Min/Max window 02269| ,, , AddressRangeMemory, TypeStatic) 02270| }) 02271| Method (_CRS, 0, Serialized) ==================================================================================================== ADVICE: (for error #4050): The minimum address is greater than the maximum address. This is illegal. FAILED [HIGH] AMLAssemblerError1104: Test 1, Assembler error in line 8885 Line | AML source ---------------------------------------------------------------------------------------------------- 08882| Method (_DIS, 0, NotSerialized) 08883| { 08884| DSOD (0x02) 08885| Return (0x00) | ^ | warning level 0 1104: Reserved method should not return a value (_DIS) 08886| } 08887| 08888| Method (_SRS, 1, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 1, Assembler error in line 9195 Line | AML source ---------------------------------------------------------------------------------------------------- 09192| Method (_DIS, 0, NotSerialized) 09193| { 09194| DSOD (0x01) 09195| Return (0x00) | ^ | warning level 0 1104: Reserved method should not return a value (_DIS) 09196| } 09197| 09198| Method (_SRS, 1, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1127: Test 1, Assembler error in line 9242 Line | AML source ---------------------------------------------------------------------------------------------------- 09239| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y21._MAX, MAX2) 09240| CreateByteField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y21._LEN, LEN2) 09241| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y22._INT, IRQ0) 09242| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y23._DMA, DMA0) | ^ | warning level 0 1127: ResourceTag smaller than Field (Tag: 8 bits, Field: 16 bits) 09243| If (RLPD) 09244| { 09245| Store (0x00, Local0) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1128: Test 1, Assembler error in line 18682 Line | AML source ---------------------------------------------------------------------------------------------------- 18679| Store (0x01, Index (DerefOf (Index (Local0, 0x02)), 0x01)) 18680| If (And (WDPE, 0x40)) 18681| { 18682| Wait (\_SB.BEVT, 0x10) | ^ | warning level 0 1128: Result is not used, possible operator timeout will be missed 18683| } 18684| 18685| Store (BRID, Index (DerefOf (Index (Local0, 0x02)), 0x02)) ==================================================================================================== ADVICE: (for warning level 0 #1128): The operation can possibly timeout, and hence the return value indicates an timeout error. However, because the return value is not checked this very probably indicates that the code is buggy. A possible scenario is that a mutex times out and the code attempts to access data in a critical region when it should not. This will lead to undefined behaviour. This should be fixed. Table DSDT (0) reassembly: Found 2 errors, 4 warnings. Test 2 of 2: Disassemble and reassemble SSDT PASSED: Test 2, SSDT (0) reassembly, Found 0 errors, 0 warnings. FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 60 Line | AML source ---------------------------------------------------------------------------------------------------- 00057| { 00058| Store (CPDC (Arg0), Local0) 00059| GCAP (Local0) 00060| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00061| } 00062| 00063| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 174 Line | AML source ---------------------------------------------------------------------------------------------------- 00171| { 00172| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00173| GCAP (Local0) 00174| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00175| } 00176| 00177| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 244 Line | AML source ---------------------------------------------------------------------------------------------------- 00241| { 00242| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00243| GCAP (Local0) 00244| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00245| } 00246| 00247| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 290 Line | AML source ---------------------------------------------------------------------------------------------------- 00287| { 00288| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00289| GCAP (Local0) 00290| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00291| } 00292| 00293| Method (_OSC, 4, NotSerialized) ==================================================================================================== Table SSDT (1) reassembly: Found 0 errors, 4 warnings. PASSED: Test 2, SSDT (2) reassembly, Found 0 errors, 0 warnings. PASSED: Test 2, SSDT (3) reassembly, Found 0 errors, 0 warnings. ==================================================================================================== 3 passed, 10 failed, 0 warnings, 0 aborted, 0 skipped, 0 info only. ==================================================================================================== Critical failures: 1 method test, at 1 log line: 1449: Detected error 'Package limit' when evaluating '\_SB_.PCI0.GFX0.DD02._BCM'. High failures: 11 klog test, at 1 log line: 121: HIGH Kernel message: [ 3.512783] ACPI Error: Method parse/execution failed [\_SB_.PCI0.GFX0._DOD] (Node f7425858), AE_AML_PACKAGE_LIMIT (20110623/psparse-536) syntaxcheck test, at 1 log line: 1668: Assembler error in line 2261 syntaxcheck test, at 1 log line: 1687: Assembler error in line 2268 syntaxcheck test, at 1 log line: 1703: Assembler error in line 8885 syntaxcheck test, at 1 log line: 1716: Assembler error in line 9195 syntaxcheck test, at 1 log line: 1729: Assembler error in line 9242 syntaxcheck test, at 1 log line: 1742: Assembler error in line 18682 syntaxcheck test, at 1 log line: 1766: Assembler error in line 60 syntaxcheck test, at 1 log line: 1779: Assembler error in line 174 syntaxcheck test, at 1 log line: 1792: Assembler error in line 244 syntaxcheck test, at 1 log line: 1805: Assembler error in line 290 Medium failures: 9 mtrr test, at 1 log line: 76: Memory range 0xc0000000 to 0xdfffffff (PCI Bus 0000:00) has incorrect attribute Write-Combining. mtrr test, at 1 log line: 78: Memory range 0xfee01000 to 0xffffffff (PCI Bus 0000:00) has incorrect attribute Write-Protect. msr test, at 1 log line: 165: MSR SYSENTER_ESP (0x175) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0xffffffffffffffff). msr test, at 1 log line: 173: MSR MISC_ENABLE (0x1a0) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0x400c51889). wmi test, at 1 log line: 528: GUID 2B814318-4BE8-4707-9D84-A190A859B5D0 is unknown to the kernel, a driver may need to be implemented for this GUID. method test, at 1 log line: 1002: \_SB_.PCI0.LPCB.SIO_.COM1._DIS returned values, but was expected to return nothing. method test, at 1 log line: 1011: \_SB_.PCI0.LPCB.SIO_.LPT0._DIS returned values, but was expected to return nothing. method test, at 1 log line: 1443: Method _BCL should return a package of more than 2 integers, got just 2. acpitables test, at 1 log line: 1643: FADT 32 bit FIRMWARE_CONTROL is non-zero, and X_FIRMWARE_CONTROL is also non-zero. Se

    Read the article

< Previous Page | 36 37 38 39 40 41 42 43 44 45 46 47  | Next Page >