Search Results

Search found 2524 results on 101 pages for 'rach 90'.

Page 40/101 | < Previous Page | 36 37 38 39 40 41 42 43 44 45 46 47  | Next Page >

  • iptables -L lags on non localhost or anywhere address

    - by DazSlayer
    I am trying to configure iptables for ubuntu 10.04 and I have a problem with iptables -L lagging on rows where the destination or source address is not localhost or anywhere. The following entries will cause lag on their row: iptables -A INPUT -p tcp --dport 111 -s 192.168.1.14 -j ACCEPT iptables -A INPUT -p tcp --dport 90 -d 192.168.1.14 -j ACCEPT while this does not: iptables -A INPUT -p tcp --dport localhost -s 192.168.1.14 -j ACCEPT iptables -A INPUT -p tcp --dport localhost -d 192.168.1.14 -j ACCEPT I feel like this might be due to iptables checking to see if the ip is reachable. If not, what is the cause, if it is how can I disable it?

    Read the article

  • Fortigate 200A firewall CPU high resource usage

    - by user119720
    This morning I'm receiving complaints from several end users that saying their whole department network are slow and have intermittent. Therefore I've checked our firewall to see whether if something goes wrong with the device.From my observation in the FortiGate dashboard status, the CPU resources is very high (99 percent). My first assumption is to clear the log since in the alert log the Fortigate log mention that it is already 90% full.Based on my understanding,the log can be cleared by restarting the firewall. After restarting the firewall the network seems okay again but then after several minutes it went up again.The condition still persist until now. Can someone show me where else I can check to fix this issue? I've really appreciate any help that I can get here.Thanks. Edit: diag sys top command

    Read the article

  • Laptop hot after format

    - by Dany Khalife
    I recently formatted an HP G62 Laptop and installed all drivers from the HP site that should be installed for this model. But i noticed a very strange behavior, using Coretemp, the temp is always above 50 (on idle) and reaches 70 very quickly sometimes (Critical is 90) If i open youtube or skype alone, i can get temperatures as high as 83. Normally it was around 32 (on idle) and reaches 70 when i open games but not youtube.... I have a i3 processor and AMD graphics so i am wondering if somehow it's a graphics card issue (since i3 has integrated graphics as far as i know) Device manager shows only AMD graphics card tho, not sure if i3 graphics should appear here too. Any ideas what i might have forgotten to do after the format ?

    Read the article

  • Laptop hot after format

    - by Dany Khalife
    I recently formatted an HP G62 Laptop and installed all drivers from the HP site that should be installed for this model. But i noticed a very strange behavior, using Coretemp, the temp is always above 50 (on idle) and reaches 70 very quickly sometimes (Critical is 90) If i open youtube or skype alone, i can get temperatures as high as 83. Normally it was around 32 (on idle) and reaches 70 when i open games but not youtube.... I have a i3 processor and AMD graphics so i am wondering if somehow it's a graphics card issue (since i3 has integrated graphics as far as i know) Device manager shows only AMD graphics card tho, not sure if i3 graphics should appear here too. Any ideas what i might have forgotten to do after the format ?

    Read the article

  • Spam just keeps on coming

    - by Campo
    I administer a Windows Server 2003 with Exchange 2003 as well as GFI installed. I am watching the GFI dashboard and every third email is spam. Not only that it goes to a non existent address then the [email protected] sends out an NDR to the sender. Should I be worried about this? I know it is directory harvesting but we have directory harvesting turned on in GFI and I do see it is working but obviously doesn't work for emails that don't exist. My issue is I would turn off NDR but then people who legitimately mistype and email address to our domain will never know their email did not get to the recipient. What do others do to combat spam? Is 3 times the amount of spam to ham normal? We filter out 90% of the spam but some does get into the users inbox. Thanks for the suggestions and advice!

    Read the article

  • Improving TCP performance over a gigabit network lots of connections and high traffic for storage and streaming services

    - by Linux Guy
    I have two servers, Both servers hardware Specification are Processor : Dual Processor RAM : over 128 G.B Hard disk : SSD Hard disk Outging Traffic bandwidth : 3 Gbps network cards speed : 10 Gbps Server A : for Encoding videos Server B : for storage videos andstream videos over web interface like youtube The inbound bandwidth between two servers is 10Gbps , the outbound bandwidth internet bandwidth is 500Mpbs Both servers using public ip addresses in public and private network Both servers transfer and connection on nginx port , and the server B used for streaming media , like youtube stream videos Both servers in same network , when i do ping from Server A to Server B i got high time latency above 1.0ms , the time range time=52.7 ms to time=215.7 ms - This is the output of iftop utility 353Mb 707Mb 1.04Gb 1.38Gb 1.73Gb mqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqq server.example.com => ip.address 6.36Mb 4.31Mb 1.66Mb <= 158Kb 94.8Kb 35.1Kb server.example.com => ip.address 1.23Mb 4.28Mb 1.12Mb <= 17.1Kb 83.5Kb 21.9Kb server.example.com => ip.address 395Kb 3.89Mb 1.07Mb <= 6.09Kb 109Kb 28.6Kb server.example.com => ip.address 4.55Mb 3.83Mb 1.04Mb <= 55.6Kb 45.4Kb 13.0Kb server.example.com => ip.address 649Kb 3.38Mb 1.47Mb <= 9.00Kb 38.7Kb 16.7Kb server.example.com => ip.address 5.00Mb 3.32Mb 1.80Mb <= 65.7Kb 55.1Kb 29.4Kb server.example.com => ip.address 387Kb 3.13Mb 1.06Mb <= 18.4Kb 39.9Kb 15.0Kb server.example.com => ip.address 3.27Mb 3.11Mb 1.01Mb <= 81.2Kb 64.5Kb 20.9Kb server.example.com => ip.address 1.75Mb 3.08Mb 2.72Mb <= 16.6Kb 35.6Kb 32.5Kb server.example.com => ip.address 1.75Mb 2.90Mb 2.79Mb <= 22.4Kb 32.6Kb 35.6Kb server.example.com => ip.address 3.03Mb 2.78Mb 1.82Mb <= 26.6Kb 27.4Kb 20.2Kb server.example.com => ip.address 2.26Mb 2.66Mb 1.36Mb <= 51.7Kb 49.1Kb 24.4Kb server.example.com => ip.address 586Kb 2.50Mb 1.03Mb <= 4.17Kb 26.1Kb 10.7Kb server.example.com => ip.address 2.42Mb 2.49Mb 2.44Mb <= 31.6Kb 29.7Kb 29.9Kb server.example.com => ip.address 2.41Mb 2.46Mb 2.41Mb <= 26.4Kb 24.5Kb 23.8Kb server.example.com => ip.address 2.37Mb 2.39Mb 2.40Mb <= 28.9Kb 27.0Kb 28.5Kb server.example.com => ip.address 525Kb 2.20Mb 1.05Mb <= 7.03Kb 26.0Kb 12.8Kb qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq TX: cum: 102GB peak: 1.65Gb rates: 1.46Gb 1.44Gb 1.48Gb RX: 1.31GB 24.3Mb 19.5Mb 18.9Mb 20.0Mb TOTAL: 103GB 1.67Gb 1.48Gb 1.46Gb 1.50Gb I check the transfer speed using iperf utility From Server A to Server B # iperf -c 0.0.0.2 -p 8777 ------------------------------------------------------------ Client connecting to 0.0.0.2, TCP port 8777 TCP window size: 85.3 KByte (default) ------------------------------------------------------------ [ 3] local 0.0.0.1 port 38895 connected with 0.0.0.2 port 8777 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.8 sec 528 KBytes 399 Kbits/sec My Current Connections in Server B # netstat -an|grep ":8777"|awk '/tcp/ {print $6}'|sort -nr| uniq -c 2072 TIME_WAIT 28 SYN_RECV 1 LISTEN 189 LAST_ACK 139 FIN_WAIT2 373 FIN_WAIT1 3381 ESTABLISHED 34 CLOSING Server A Network Card Information Settings for eth0: Supported ports: [ TP ] Supported link modes: 100baseT/Full 1000baseT/Full 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: Yes Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: Yes Speed: 10000Mb/s Duplex: Full Port: Twisted Pair PHYAD: 0 Transceiver: external Auto-negotiation: on MDI-X: Unknown Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes Server B Network Card Information Settings for eth2: Supported ports: [ FIBRE ] Supported link modes: 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: No Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: No Speed: 10000Mb/s Duplex: Full Port: Direct Attach Copper PHYAD: 0 Transceiver: external Auto-negotiation: off Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes ifconfig server A eth0 Link encap:Ethernet HWaddr 00:25:90:ED:9E:AA inet addr:0.0.0.1 Bcast:0.0.0.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1202795665 errors:0 dropped:64334 overruns:0 frame:0 TX packets:2313161968 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:893413096188 (832.0 GiB) TX bytes:3360949570454 (3.0 TiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:2207544 errors:0 dropped:0 overruns:0 frame:0 TX packets:2207544 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:247769175 (236.2 MiB) TX bytes:247769175 (236.2 MiB) ifconfig Server B eth2 Link encap:Ethernet HWaddr 00:25:90:82:C4:FE inet addr:0.0.0.2 Bcast:0.0.0.2 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:39973046980 errors:0 dropped:1828387600 overruns:0 frame:0 TX packets:69618752480 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3013976063688 (2.7 TiB) TX bytes:102250230803933 (92.9 TiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:1049495 errors:0 dropped:0 overruns:0 frame:0 TX packets:1049495 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:129012422 (123.0 MiB) TX bytes:129012422 (123.0 MiB) Netstat -i on Server B # netstat -i Kernel Interface table Iface MTU Met RX-OK RX-ERR RX-DRP RX-OVR TX-OK TX-ERR TX-DRP TX-OVR Flg eth2 9000 0 42098629968 0 2131223717 0 73698797854 0 0 0 BMRU lo 65536 0 1077908 0 0 0 1077908 0 0 0 LRU I Turn up send/receive buffers on the network card to 2048 and problem still persist I increase the MTU for server A and problem still persist and i increase the MTU for server B for better connectivity and transfer speed but it couldn't transfer at all The problem is : as you can see from iperf utility, the transfer speed from server A to server B slow when i restart network service in server B the transfer in server A at full speed, after 2 minutes , it's getting slow How could i troubleshoot slow speed issue and fix it in server B ? Notice : if there any other commands i should execute in servers for more information, so it might help resolve the problem , let me know in comments

    Read the article

  • Planning to buy a server with at least 48GB Ram, are the blades way to go?

    - by varchar1
    We're planning to host our website for the first time for ourselves. We have currently have a linode of 8 gigs and the memory is going up to 90% most of the time. So I want to move my website to my own server with huge RAM. So this will be first time to manage any physical hardware of a server. So I came across IBM's BladeCenter, found them interesting. So can I just buy the blade and run it? Or do I have to buy the chassis for sure? Also, do I need to buy an UPS? So how hard is it to setup? How about the hard drives? Can I setup them easily? Please advice.

    Read the article

  • Log monitoring using Zabbix

    - by Supratik
    I am trying to monitor a log file using Zabbix 1.8.4. I created an item using the following details: Host: Zabbix server Description: logger_test Type: Zabbix agent (active) Key: log[/tmp/scribetest/test3/test3_current,error,,100] Type of Infromation: Log Update interval (in sec): 1 sec Keep history (in days): 90 Status: Active Applications: Log files I created a trigger and attached it with the item logger_test using the following details: Name: logger_test_trigger Expression: {Zabbix server:log[/tmp/scribetest/test3/test3_current,error,,100].str(error)}=1 Severity: disaster The above settings works fine for the first time but next time the trigger shows ZBX_NOTSUPPORTED and after that item also shows "not supported" message. Can you please tell me if anything I am doing wrong here ?

    Read the article

  • Image Magick and Ghostscript

    - by user114671
    I mainly do web design but I host a few client sites on a Centos 5 VPS. A new client has asked me to host their site and I've been given the following configuration requirement: Apache 2.2.3 PHP 5.2.17 MySQL 5.0.77 Image Magick 6.5.1-0 (not as an Apache module) Ghostscript 8.7 Checking php_info() I have: Apache 2.2.3 PHP 5.2.14 MySQL 5.0.90 I don't have IM or GS listed. I expect that my versions of PHP and MySQL are similar enough to work, but how do I get my server set up to work with this client's site as well?

    Read the article

  • set tap0 using virt-manager for bridged wireless

    - by DaveO
    After 3 days I finally have kvm guests working on the network via wireless (link below - thanks!): My network is 192.168.1.0/24 on the host: sudo sh -c "echo 1 > /proc/sys/net/ipv4/ip_forward" sudo tunctl -t tap0 sudo ip link set tap0 up sudo ip addr add 192.168.1.25/24 dev tap0 sudo route add -host 192.168.1.30 dev tap0 sudo parprouted wlan0 tap0 on the guest: auto eth0 iface eth0 inet static address 192.168.1.30 netmask 255.255.255.0 network 192.168.1.0 broadcast 192.168.1.255 gateway 192.168.1.25 and start the guest: sudo kvm /path/to/guest.img -net nic,macaddr=DE:AD:BE:EF:90:26 -net tap,ifname=tap0,script=no This works great and I can ping the local network and the internet back and forth between the guest. But how do I add these settings to the guest's xml config so I can start the guest via virt-manager with the same nic settings? ref: http://www.linuxquestions.org/questions/debian-26/kvm-wireless-bridge-network-691953/

    Read the article

  • Problem with intel chipset 4 serie and centos dealing with dual head

    - by Antoine
    I've a fujitsu lifebook S7220, it's been a while since i try to configure it to use a dual head with centos 5.4 x86_64. Everytime I try, the xserver crash... I've got an intel chipset mobile 4 serie (GMA 4500MHD, if I recall good!) When I do an lspci -v i've got these : 00:02.0 VGA compatible controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) (prog-if 00 [VGA controller]) Subsystem: Fujitsu Limited. Unknown device 1451 Flags: bus master, fast devsel, latency 0, IRQ 177 Memory at f2000000 (64-bit, non-prefetchable) [size=4M] Memory at d0000000 (64-bit, prefetchable) [size=256M] I/O ports at 1800 [size=8] Capabilities: [90] Message Signalled Interrupts: 64bit- Queue=0/0 Enable- Capabilities: [d0] Power Management version 3 00:02.1 Display controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) Subsystem: Fujitsu Limited. Unknown device 1451 Flags: bus master, fast devsel, latency 0 Memory at f2400000 (64-bit, non-prefetchable) [size=1M] Capabilities: [d0] Power Management version 3 My question is, anyone already got this problem and how did you fix it? Thank you for your answer!

    Read the article

  • Internet Explorer 10 auto-correct randomly capitalises words

    - by Andreas Rejbrand
    I use Internet Explorer 10 on my Windows 7 laptop (because the fingerprint browser add-on only works in IE). I have noticed that IE 10 has a built-in spellchecker, which is great. Now, I write about 90 % English and 10 % Swedish on web sites, so it is somewhat unfortunate that it isn't possible to change the spell-checker language 'on-the-fly'. But that's a minor issue. The main problem is that, when I write English comments, the spell-checker (apparently randomly) capitalises some Words. For instance, the 'words' of the previous sentence was changed automatically to 'Words'. Another Word that is Always capitalised is Before. (Yes, the Three Words that are incorrectly capitalised in the previous sentence are due to the auto-correct 'feature', and apparently 'three' is also a problematic word.) Is this really something that happens to every (bilingual) user? Is there any way to fix the issue (preferably without disabling the spell-checker altogether)?

    Read the article

  • Log monitoring using Zabbix

    - by Supratik
    Hi I am monitoring logs using Zabbix. I am trying to monitor a log file using Zabbix 1.8.4. I created an item using the following details: Host: Zabbix server Description: logger_test Type: Zabbix agent (active) Key: log[/tmp/scribetest/test3/test3_current,error,,100] Type of Infromation: Log Update interval (in sec): 1 sec Keep history (in days): 90 Status: Active Applications: Log files I created a trigger and attached it with the item logger_test using the following details. Name: logger_test_trigger Expression: {Zabbix server:log[/tmp/scribetest/test3/test3_current,error,,100].str(error)}=1 Severity: disaster The above settings works fine for the first time but next time the trigger shows ZBX_NOTSUPPORTED and after that item also shows "not supported" message. Can you please tell me if anything I am doing wrong here ? Warm Regards Supratik

    Read the article

  • Setting a Static IP Running FreeBSD8 in VirtualBox hosted on Windows 7

    - by gvkv
    I'm using VirtualBox on Windows 7 (host) to run a FreeBSD (guest) based web server. I`ve assigned a static ip of 192.168.80. 1 to the (virtualized) NIC which is run in bridged mode. The problem is that when I ping an external server (such as google.com) I get a No route to host error: dimetro# ping google.com PING google.com (66.249.90.104): 56 data bytes ping: sendto: No route to host ... I can ping the BSD server from both another virtualized machine and my host machine and from the server, I can ping everything on the network. The router ip is 192.168.1.1/16. ADDENDUM: I have the following lines in /etc/rc.conf on the BSD VM to configure networking: defaultrouter="192.168.1.1" ifconfig_em0="inet 192.168.80.1 netmask 255.255.0.0"

    Read the article

  • Re-Calibrate Toshiba battery meter with Windows 7

    - by Farseeker
    Hi All. I have a Toshiba U300 laptop. Back in the olden days (circa-2000) you could re-calibrate the battery meter from the BIOS when your battery was no longer reading accurately. My battery was shot, so I bought a brand new one, however Windows 7 still seems to count down the battery life in at the same speed as the old one did. This time, when it alleged 0%, I turned the laptop back on and got another 90 minutes of life out of it, at 0%. Is there a tool or utility for Toshiba laptops that can fix it back to being accurate? I've read the other threads on SU about cycling the battery but that just doesn't seem to do it in this case. Update: After the last cycle, the battery meter now reads 100% but the indicator on the front of the laptop is still orange (indicating not fully charged)

    Read the article

  • XCP vm created via xl create doesn't show up in Xencenter neither in xe vm-list

    - by user138664
    i am running XCP 1.4.90.530.170661 and i have many PV guests running and created via XenCenter. I have created now an openwrt PV guest via the xl create command but it doesn't show up in Xencenter neither in the vm-list command: xe vm-list uuid ( RO) : 6d29aac1-67ff-f83e-4dbc-894a3b6b9c10 name-label ( RW): slitaz power-state ( RO): running uuid ( RO) : 07d96dd1-8223-cd1c-587d-ae37e48d267b name-label ( RW): xen-centos6 power-state ( RO): running uuid ( RO) : 3164bcf1-e43c-badb-e0cf-5423751fffb9 name-label ( RW): xenwin7 power-state ( RO): running uuid ( RO) : 8a31725e-4bcb-48ac-ba7b-e7c1ba310789 name-label ( RW): Control domain on host: xen-mini power-state ( RO): running xl list Name ID Mem VCPUs State Time(s) Domain-0 0 300 2 r----- 4862.5 xenwin7 2 766 1 -b---- 4933.1 slitaz 10 255 1 -b---- 30.8 xen-centos6 11 767 1 -b---- 46.9 openwrt 12 32 1 -b---- 6.8 are these two different kinds of PV vm? if yes, is there a way to export the "xl create" one as xva/ova and import it to show up like the others? Thanks in advance, /c/

    Read the article

  • RAID 1 not performing as expected

    - by Faken
    I recently bought a new 320Gb hard drive for my computer to set up RAID 1 on it for some added security. Installation went as smooth as could possibly be (plug in power, plug in data cable, start up computer, Intel software recognized new drive, right click create RAID 1, done!). However, for some inexplicable reason, I seem to have strange test results when using BENCH32. On my old configuration, a single 7200 rpm drive, I achieved about 60 MB/s write and 70 MB/s read. With a new RAID 1 configuration, I would expect the write to be slightly diminished but read to be significantly improved (though not exactly double speed). However, with the new configuration, I am getting 90 MB/s write and only about 80 MB/s read. I should NOT be getting improved write performance, especially NOT better than read! What's going on? My system setup is: q6600 2.4ghz CPU 4Gb DDR2 667mhz RAM on board Intel ICH9R "RAID chip" 2x Seagate 7200 RPM 320GB drives in RAID 1 Widows 7 home premium 64-bit

    Read the article

  • High fan speed after return from suspend (on Ubuntu)

    - by Bolo
    Hi, I've got a HP ProBook 5310m laptop with Ubuntu 10.04 (32 bit). When I return from suspend, the fan speed is usually very high: FDTZ sensor reports "90 °C". Yes, the units are wrong, since FDTZ does not report temperature, but fan speed – that's probably just a small bug in reporting. Interestingly, when I plug or unplug the power cable for a moment, the fan speed returns back to normal. My questions: Where can I report this problem? Is it about ACPI support in the kernel? What is the address of the relevant bug tracker? As a workaround for now, how can I programmatically trigger a behavior equivalent to (un)plugging the power cable. More generally, how can I force ACPI to recalculate fan speed? Ideally, I'm looking for something like echo foo > /proc/bar. Thanks in advance!

    Read the article

  • Monitoring server room temperature

    - by user640
    I have a small server room with its own AC unit. Recently, the AC died, and the temperature increased from 70 F to 90 F. We rarely go in this room, so I was lucky that someone happened to notice that the fans were running a lot louder than normal as they walked past the door. It looks like I need a way to be notified when the temperature in that room gets too hot. What tools are you using to monitor the temperature in your server room? How does this tool notify you of a problem (email, SNMP, etc). Note: I've read this question on server temperature, but I'm interested in the whole room, not just the inside of a server case. Edit: Thanks for all the great responses so far! Many of these products measure much more than just temperature. What else should I be looking at and why?

    Read the article

  • Looking for Mini itx capable of running Photoshop + Illustrator (cs4 or higher)

    - by drozzy
    Ok, so I want to build a small pc for my gf that she can take with her instead of the crappy laptop that she has. Overall I think the complete system should not weight more than 10 lbs. The requirements are to run at least 4 applications simultaneously, and be able to switch between them with no problems: Photoshop Illustrator Word editor Browser Should be able to handle 1920x1200 resolution. I am currently looking at LGA775 socket as I can just transfer my desktop cpu Q6600 to it. Currently deciding between DQ45EK and DG41TX, but any other suggestions are welcome. So I am thinking something along the lines of: MINI-BOX M350 Case with 90 watt psu Q6600 cpu (my desktop cpu) 2x2GB kingston ram (or similar) Video? Need external or built-in G45 on DQ45EK will do? My primary concern is whether the 90WATT is sufficient of the Q6600? Thanks

    Read the article

  • set tap0 using virt-manager for bridged wireless

    - by DaveO
    After 3 days I finally have kvm guests working on the network via wireless (link below - thanks!): My network is 192.168.1.0/24 on the host: sudo sh -c "echo 1 > /proc/sys/net/ipv4/ip_forward" sudo tunctl -t tap0 sudo ip link set tap0 up sudo ip addr add 192.168.1.25/24 dev tap0 sudo route add -host 192.168.1.30 dev tap0 sudo parprouted wlan0 tap0 on the guest: auto eth0 iface eth0 inet static address 192.168.1.30 netmask 255.255.255.0 network 192.168.1.0 broadcast 192.168.1.255 gateway 192.168.1.25 and start the guest: sudo kvm /path/to/guest.img -net nic,macaddr=DE:AD:BE:EF:90:26 -net tap,ifname=tap0,script=no This works great and I can ping the local network and the internet back and forth between the guest. But how do I add these settings to the guest's xml config so I can start the guest via virt-manager with the same nic settings? ref: http://www.linuxquestions.org/questions/debian-26/kvm-wireless-bridge-network-691953/

    Read the article

  • timeout with apache & php w/ each virtual host has his own user process

    - by acemtp
    I have 10 unix users in /home/. Each user is for a specific subdomain for example user www in /home/www/public_html is for www.mywebsite. blog in /home/blog/public_html is for blog.mywebsite. 90% is php and 10% ror for the moment i use apache + fastcgi that use SuexecUserGroup to setup the process with the good user. it seems to works but i have a strange behavior where after a few hours/days, the server stop answering (timeout) but the cpu load is still very low (it's a big server), the apache status display lot of "W" Sending Reply states but there's still 50 idle workers so it should be able to answer. in the older server (lot of slower) we add only one user and using mod_php and we never had this issue. is there another way to do that without fastcgi and SuexecUserGroup or do you know what's going wrong?

    Read the article

  • Serious voltage and temperature problems

    - by James Willson
    My computer has been acting up when I play games so I wanted to look into why. Issue 1: GPU Temp According to afterburner and speedfan my 8800GTX idles at 90 degrees and then when playing games shoots up to over 110C which is when my graphics basically starts to give rendering issues. Issue 2: CPU Temp Speedfan is saying my CPU temp is 83C idle but when I look at core temp it says core0 is at 35C and core1 is at 33C. Issue 3: Voltages This is what speedfan is saying for my voltages: Vcore1: 1.01V Vcore2: 1.90V +3.3V: 3.31V +5V: 4.95V +12V: 0.51V -12V: -16.80V -5V: -8.43V +5V 5.13V Vbat: 3.25V Vcore: 3.00V +3.3V: 3.20V These voltages, for lack of a better word, look f*cked. With all this happening, the computer runs ok under normal use. Is the software giving out incorrect readouts or instead should I immediately move the computer into another room before it explodes? P.s I would like to add this is a stock system. EVGA 8800GTX, E6850 CPU, 800W PSU

    Read the article

  • pymatplotlib without xserver

    - by vigilant
    Is it possible to use networkx or pymatplotlib without an xserver running? I keep getting the following error with their first example (of networkx): Traceback (most recent call last): File "test.py", line 17, in <module> nx.draw(G,pos,node_color='#A0CBE2',edge_color=colors,width=4,edge_cmap=plt.cm.Blues,with_labels=False) File "/usr/local/lib/python2.6/dist-packages/networkx-1.3-py2.6.egg/networkx/drawing/nx_pylab.py", line 124, in draw cf=pylab.gcf() File "/usr/lib/pymodules/python2.6/matplotlib/pyplot.py", line 276, in gcf return figure() File "/usr/lib/pymodules/python2.6/matplotlib/pyplot.py", line 254, in figure **kwargs) File "/usr/lib/pymodules/python2.6/matplotlib/backends/backend_tkagg.py", line 90, in new_figure_manager window = Tk.Tk() File "/usr/lib/python2.6/lib-tk/Tkinter.py", line 1646, in __init__ self.tk = _tkinter.create(screenName, baseName, className, interactive, wantobjects, useTk, sync, use) _tkinter.TclError: couldn't connect to display ""

    Read the article

  • HDFS datanode startup fails when disks are full

    - by mbac
    Our HDFS cluster is only 90% full but some datanodes have some disks that are 100% full. That means when we mass reboot the entire cluster some datanodes completely fail to start with a message like this: 2013-10-26 03:58:27,295 ERROR org.apache.hadoop.hdfs.server.datanode.DataNode: java.io.IOException: Mkdirs failed to create /mnt/local/sda1/hadoop/dfsdata/blocksBeingWritten Only three have to fail this way before we start experiencing real data loss. Currently we workaround it by decreasing the amount of space reserved for the root user but we'll eventually run out. We also run the re-balancer pretty much constantly, but some disks stay stuck at 100% anyway. Changing the dfs.datanode.failed.volumes.tolerated setting is not the solution as the volume has not failed. Any ideas?

    Read the article