  • Intel Centrino Wireless N 1000 doesn't work on a Lenovo Z560

    - by Timetraveler
    I upgraded my Ubuntu 11.04 to 11.10 and my Wifi has stopped working. I have a Lenovo Z560 that has Intel centrino wireless-N 1000. I have searched various threads having similar problems for a solution and have no success. The wlan0 is not even showing up in rfkill. Please help me find a solution. I am giving below the output of various debug commands. Thanks in advance. DISTRIB_ID=Ubuntu DISTRIB_RELEASE=11.10 DISTRIB_CODENAME=oneiric DISTRIB_DESCRIPTION="Ubuntu 11.10" ----##uname -a Linux gurucharapathy-laptop 3.0.0-17-generic-pae #30-Ubuntu SMP Thu Mar 8 17:53:35 UTC 2012 i686 i686 i386 GNU/Linux ----##lspci -nnk | grep -iA2 net 05:00.0 Network controller [0280]: Intel Corporation Centrino Wireless-N 1000 [8086:0084] Subsystem: Intel Corporation Centrino Wireless-N 1000 BGN [8086:1315] Kernel modules: iwlagn 06:00.0 Ethernet controller [0200]: Realtek Semiconductor Co., Ltd. RTL8101E/RTL8102E PCI Express Fast Ethernet controller [10ec:8136] (rev 02) Subsystem: Lenovo Device [17aa:392e] Kernel driver in use: r8169 ----##iwconfig lo no wireless extensions. eth0 no wireless extensions. ----##iwlist scan lo Interface doesn't support scanning. eth0 Interface doesn't support scanning. ----##rfkill list all 0: hci0: Bluetooth Soft blocked: no Hard blocked: no 1: ideapad_wlan: Wireless LAN Soft blocked: no Hard blocked: no 2: ideapad_bluetooth: Bluetooth Soft blocked: no Hard blocked: no ----##lsmod Module Size Used by rfcomm 38408 8 bnep 17923 2 parport_pc 32114 0 ppdev 12849 0 binfmt_misc 17292 1 snd_hda_codec_hdmi 31426 1 snd_hda_codec_conexant 52460 1 uvcvideo 67271 0 videodev 85626 1 uvcvideo snd_hda_intel 28358 2 snd_hda_codec 91859 3 snd_hda_codec_hdmi,snd_hda_codec_conexant,snd_hda_intel snd_hwdep 13276 1 snd_hda_codec joydev 17393 0 snd_pcm 80435 3 snd_hda_codec_hdmi,snd_hda_intel,snd_hda_codec snd_seq_midi 13132 0 i915 509554 9 drm_kms_helper 32889 1 i915 snd_rawmidi 25241 1 snd_seq_midi snd_seq_midi_event 14475 1 snd_seq_midi snd_seq 51567 2 snd_seq_midi,snd_seq_midi_event snd_timer 28932 2 snd_pcm,snd_seq drm 196290 5 i915,drm_kms_helper snd_seq_device 14172 3 snd_seq_midi,snd_rawmidi,snd_seq mei 36466 0 mac80211 393421 0 snd 55902 14 snd_hda_codec_hdmi,snd_hda_codec_conexant,snd_hda_intel,snd_hda_codec,snd_hwdep,snd_pcm,snd_rawmidi,snd_seq,snd_timer,snd_seq_device ideapad_laptop 13575 0 intel_ips 17753 0 btusb 18160 2 i2c_algo_bit 13199 1 i915 soundcore 12600 1 snd bluetooth 148839 23 rfcomm,bnep,btusb cfg80211 172427 1 mac80211 psmouse 63474 0 serio_raw 12990 0 snd_page_alloc 14108 2 snd_hda_intel,snd_pcm sparse_keymap 13658 1 ideapad_laptop wmi 18744 0 video 18908 1 i915 lp 17455 0 parport 40930 3 parport_pc,ppdev,lp ahci 21634 2 libahci 25761 1 ahci r8169 47200 0 ----##nm-tool NetworkManager Tool State: asleep Device: eth0 ----------------------------------------------------------------- Type: Wired Driver: r8169 State: unmanaged Default: no HW Address: 88:AE:1D:DE:5F:9C Capabilities: Carrier Detect: yes Speed: 100 Mb/s Wired Properties Carrier: on ----##lshw -C network *-network UNCLAIMED description: Network controller product: Centrino Wireless-N 1000 vendor: Intel Corporation physical id: 0 bus info: pci@0000:05:00.0 version: 00 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: latency=0 resources: memory:d6400000-d6401fff *-network description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:06:00.0 logical name: eth0 version: 02 serial: 88:ae:1d:de:5f:9c size: 100Mbit/s capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=N/A ip=192.168.0.100 latency=0 link=yes multicast=yes port=MII speed=100Mbit/s resources: irq:41 ioport:2000(size=256) memory:d2410000-d2410fff memory:d2400000-d240ffff memory:d2420000-d243ffff

    Read the article

  • PPTP VPN connects via NM but goes down during SSH connection

    - by Andrea Olivato
    I setup a VPN PPTP connection via network manager and it connects correctly (I see the lock near the notification icon and the message "Vpn connection has been successfully...") As soon as I try to perform any SSH connection via the established tunnel the connection itself goes down with the message "Vpn connection failed". the SSH connection always fails at debug1: SSH2_MSG_KEXINIT sent I've looked into the system logs and this is the log Dec 12 12:25:00 ushuaia NetworkManager[1155]: <info> Starting VPN service 'pptp'... Dec 12 12:25:00 ushuaia NetworkManager[1155]: <info> VPN service 'pptp' started (org.freedesktop.NetworkManager.pptp), PID 7093 Dec 12 12:25:00 ushuaia NetworkManager[1155]: <info> VPN service 'pptp' appeared; activating connections Dec 12 12:25:00 ushuaia NetworkManager[1155]: <info> VPN plugin state changed: init (1) Dec 12 12:25:00 ushuaia NetworkManager[1155]: <info> VPN plugin state changed: starting (3) Dec 12 12:25:00 ushuaia NetworkManager[1155]: <info> VPN connection 'Redation' (Connect) reply received. Dec 12 12:25:05 ushuaia NetworkManager[1155]: <info> VPN connection 'Redation' (IP4 Config Get) reply received from old-style plugin. Dec 12 12:25:05 ushuaia NetworkManager[1155]: <info> VPN Gateway: 5.98.141.210 Dec 12 12:25:06 ushuaia NetworkManager[1155]: <info> VPN connection 'Redation' (IP Config Get) complete. Dec 12 12:25:06 ushuaia NetworkManager[1155]: <info> VPN plugin state changed: started (4) Dec 12 12:25:14 ushuaia NetworkManager[1155]: <info> VPN plugin state changed: stopping (5) Dec 12 12:25:14 ushuaia NetworkManager[1155]: <info> VPN plugin state changed: stopped (6) Dec 12 12:25:14 ushuaia NetworkManager[1155]: <info> VPN plugin state change reason: 0 Dec 12 12:25:15 ushuaia NetworkManager[1155]: <warn> error disconnecting VPN: Could not process the request because no VPN connection was active. Dec 12 12:25:20 ushuaia NetworkManager[1155]: <info> VPN service 'pptp' disappeared Please note that the same vpn is configured on my colleagues Windows 7 and works without problem when they use putty to connect via SSH

    Read the article

  • Disaster, or Migration?

    - by Rob Farley
    This post is in two parts – technical and personal. And I should point out that it’s prompted in part by this month’s T-SQL Tuesday, hosted by Allen Kinsel. First, the technical: I’ve had a few conversations with people recently about migration – moving a SQL Server database from one box to another (sometimes, but not primarily, involving an upgrade). One question that tends to come up is that of downtime. Obviously there will be some period of time between the old server being available and the new one. The way that most people seem to think of migration is this: Build a new server. Stop people from using the old server. Take a backup of the old server Restore it on the new server. Reconfigure the client applications (or alternatively, configure the new server to use the same address as the old) Make the new server online. There are other things involved, such as testing, of course. But this is essentially the process that people tell me they’re planning to follow. The bit that I want to look at today (as you’ve probably guessed from my title) is the “backup and restore” section. If a SQL database is using the Simple Recovery Model, then the only restore option is the last database backup. This backup could be full or differential. The transaction log never gets backed up in the Simple Recovery Model. Instead, it truncates regularly to stay small. One that’s using the Full Recovery Model (or Bulk-Logged) won’t truncate its log – the log must be backed up regularly. This provides the benefit of having a lot more option available for restores. It’s a requirement for most systems of High Availability, because if you’re making sure that a spare box is up-and-running, ready to take over, then you have to be interested in the logs that are happening on the current box, rather than truncating them all the time. A High Availability system such as Mirroring, Replication or Log Shipping will initialise the spare machine by restoring a full database backup (and maybe a differential backup if available), and then any subsequent log backups. Once the secondary copy is close, transactions can be applied to keep the two in sync. The main aspect of any High Availability system is to have a redundant system that is ready to take over. So the similarity for migration should be obvious. If you need to move a database from one box to another, then introducing a High Availability mechanism can help. By turning on the Full Recovery Model and then taking a backup (so that the now-interesting logs have some context), logs start being kept, and are therefore available for getting the new box ready (even if it’s an upgraded version). When the migration is ready to occur, a failover can be done, letting the new server take over the responsibility of the old, just as if a disaster had happened. Except that this is a planned failover, not a disaster at all. There’s a fine line between a disaster and a migration. Failovers can be useful in patching, upgrading, maintenance, and more. Hopefully, even an unexpected disaster can be seen as just another failover, and there can be an opportunity there – perhaps to get some work done on the principal server to increase robustness. And if I’ve just set up a High Availability system for even the simplest of databases, it’s not necessarily a bad thing. :) So now the personal: It’s been an interesting time recently... June has been somewhat odd. A court case with which I was involved got resolved (through mediation). I can’t go into details, but my lawyers tell me that I’m allowed to say how I feel about it. The answer is ‘lousy’. I don’t regret pursuing it as long as I did – but in the end I had to make a decision regarding the commerciality of letting it continue, and I’m going to look forward to the days when the kind of money I spent on my lawyers is small change. Mind you, if I had a similar situation with an employer, I’d do the same again, but that doesn’t really stop me feeling frustrated about it. The following day I had to fly to country Victoria to see my grandmother, who wasn’t expected to last the weekend. She’s still around a week later as I write this, but her 92-year-old body has basically given up on her. She’s been a Christian all her life, and is looking forward to eternity. We’ll all miss her though, and it’s hard to see my family grieving. Then on Tuesday, I was driving back to the airport with my family to come home, when something really bizarre happened. We were travelling down the freeway, just pulled out to go past a truck (farm-truck sized, not a semi-trailer), when a car-sized mass of metal fell off it. It was something like an industrial air-conditioner, but from where I was sitting, it was just a mass of spinning metal, like something out of a movie (one friend described it as “holidays by Michael Bay”). Somehow, and I’m really don’t know how, the part of it nearest us bounced high enough to clear the car, and there wasn’t even a scratch. We pulled over the check, and I was just thanking God that we’d changed lanes when we had, and that we remained unharmed. I had all kinds of thoughts about what could’ve happened if we’d had something that size land on the windscreen... All this has drilled home that while I feel that I haven’t provided as well for the family as I could’ve done (like by pursuing an expensive legal case), I shouldn’t even consider that I have proper control over things. I get to live life, and make decisions based on what I feel is right at the time. But I’m not going to get everything right, and there will be things that feel like disasters, some which could’ve been in my control and some which are very much beyond my control. The case feels like something I could’ve pursued differently, a disaster that could’ve been avoided in some way. Gran dying is lousy of course. An accident on the freeway would have been awful. I need to recognise that the worst disasters are ones that I can’t affect, and that I need to look at things in context – perhaps seeing everything that happens as a migration instead. Life is never the same from one day to the next. Every event has a before and an after – sometimes it’s clearly positive, sometimes it’s not. I remember good events in my life (such as my wedding), and bad (such as the loss of my father when I was ten, or the back injury I had eight years ago). I’m not suggesting that I know how to view everything from the “God works all things for good” perspective, but I am trying to look at last week as a migration of sorts. Those things are behind me now, and the future is in God’s hands. Hopefully I’ve learned things, and will be able to live accordingly. I’ve come through this time now, and even though I’ll miss Gran, I’ll see her again one day, and the future is bright.

    Read the article

  • WebCenter Customer Spotlight: Global Village Telecom Ltda

    - by me
    Author: Peter Reiser - Social Business Evangelist, Oracle WebCenter  Solution SummaryGlobal Village Telecom Ltda. (GVT)  is a leading Brazilian telecommunications company, developing solutions and providing services for corporate and end users. GVT is located in Curitiba, Brazil, employs 6,000 people and has an annual revenue of around US$1 billion.  GVT business objectives were to improve corporate communications, accelerate internal information flow, provide continuous access to the all business files and  enable the company’s leadership to provide information to all departments in real time. GVT implemented Oracle WebCenter Content to centralize the company's content and they built  a portal to share and find content in real-time. Oracle WebCenter Content enabled GVT to quickly and efficiently integrate communication among all company employees—ensuring that GVT maintain a competitive edge in the market. Human Resources reduced the time required for issuing internal statements to all staff from three weeks to one day. Company OverviewGlobal Village Telecom Ltda. (GVT)  is a leading telecommunications company, developing solutions and providing services for corporate and end users. The company offers diverse innovative products and advanced solutions in conventional fixed telephone communications, data transmission, high speed broadband internet services, and voice over IP (VoIP) services for all market segment. GVT is located in Curitiba, Brazil, employs 6,000 people and have an  annual revenue of around US$1 billion.   Business ChallengesGVT business objectives were to improve corporate communications, accelerate internal information flow, provide continuous access to the all business files and enable the company’s leadership to provide information to all departments in real time. Solution DeployedGVT worked with the Oracle Partner IT7 to deploy Oracle WebCenter Content to securely centralize the company's content such as growth indicators, spreadsheets, and corporate and descriptive project schedules. The solution enabled real-time information sharing through the development of Click GVT, a portal that currently receives 100,000 monthly impressions from employee searches. Business ResultsGVT gained a competitive edge in the communications market by accelerating internal information flow, streamlining the content standardizing information and enabled real-time information sharing and discovery. Human Resources  reduced the time required for issuing  internal statements to all staff from three weeks to one day. “The competitive nature of telecommunication industry demands rapid information in the internal flow of the company. Oracle WebCenter Content enabled us to quickly and efficiently integrate communication among all company employees—ensuring that we maintain a competitive edge in the market.” Marcel Mendes Filho, Systems Manager, Global Village Telecom Ltda. Additional Information Global Viallage Telecom Ltda Customer Snapshot Oracle WebCenter Content

    Read the article

  • SCVMM – Round 2 – How to create a Private Cloud using PowerShell

    - by Waclaw Chrabaszcz
    Originally posted on: http://geekswithblogs.net/Wchrabaszcz/archive/2013/06/28/scvmm--round-2--how-to-create-a-private.aspxHave you ever seen "A Bridge too far" movie? To not to wake up a click too far, it is good to script some tasks. Yes of course we can follow wizards, but some of us want to be warriorsJ. A small tip, take a look on credentials and system GUID examples. I don't know how about you, but for me it will be really useful in the future.    # credents$credential = Get-CredentialNew-SCRunAsAccount -Name "TESTDOMAIN\Administrator" -Credential $credential #storage $opsMgrServerCredential = Get-SCRunAsAccount -Name "TESTDOMAIN\Administrator"New-SCStorageClassification -Name "Bronze" -Description "" –RunAsynchronouslyNew-SCStorageClassification -Name "Silver" -Description "" –RunAsynchronouslyNew-SCStorageClassification -Name "Gold" -Description "" –RunAsynchronously # add a shared storageFind-SCComputer -ComputerName "dc.TESTDOMAIN.net"Add-SCStorageProvider -AddWindowsNativeWmiProvider -Name "dc.TESTDOMAIN.net" -RunAsAccount $opsMgrServerCredential -ComputerName "dc.TESTDOMAIN.net"$fileServer = Get-SCStorageFileServer "dc.TESTDOMAIN.net"$fileShares = @()$fileShares += Get-SCStorageFileShare -Name "VMMLibrary"Set-SCStorageFileServer -StorageFileServer $fileServer -AddStorageFileShareToManagement $fileShares –RunAsynchronously #fabric network$logicalNetwork = New-SCLogicalNetwork -Name "TESTDOMAIN-Service-Network" -LogicalNetworkDefinitionIsolation $false -EnableNetworkVirtualization $true -UseGRE $true -IsPVLAN $false$allHostGroups = @()$allHostGroups += Get-SCVMHostGroup -Name "All Hosts"$allSubnetVlan = @()$allSubnetVlan += New-SCSubnetVLan -Subnet "10.0.0.0/24" -VLanID 0New-SCLogicalNetworkDefinition -Name "TESTDOMAIN-Service-Network_0" -LogicalNetwork $logicalNetwork -VMHostGroup $allHostGroups -SubnetVLan $allSubnetVlan #IP pool$logicalNetwork = Get-SCLogicalNetwork -Name "TESTDOMAIN-Service-Network"$logicalNetworkDefinition = Get-SCLogicalNetworkDefinition -LogicalNetwork $logicalNetwork -Name "TESTDOMAIN-Service-Network_0" # Gateways$allGateways = @()$allGateways += New-SCDefaultGateway -IPAddress "10.0.0.1" –Automatic# DNS servers $allDnsServer = @("10.0.0.1")# DNS suffixes$allDnsSuffixes = @("TESTDOMAIN.net")# WINS servers$allWinsServers = @()New-SCStaticIPAddressPool -Name "TESTDOMAIN-Service-Network" -LogicalNetworkDefinition $logicalNetworkDefinition -Subnet "10.0.0.0/24" -IPAddressRangeStart "10.0.0.51" -IPAddressRangeEnd "10.0.0.75" -DefaultGateway $allGateways -DNSServer $allDnsServer -DNSSuffix "" -DNSSearchSuffix $allDnsSuffixes –RunAsynchronously #Hyper-V Virtual Networks$logicalNetwork = Get-SCLogicalNetwork -Name "TESTDOMAIN-Service-Network" $vmNetwork = New-SCVMNetwork -Name "TESTDOMAIN-VMN" -LogicalNetwork $logicalNetwork -IsolationType "WindowsNetworkVirtualization" -CAIPAddressPoolType "IPV4" -PAIPAddressPoolType "IPV4"Write-Output $vmNetwork$subnet = New-SCSubnetVLan -Subnet "10.0.0.0/24"New-SCVMSubnet -Name "Con-SN" -VMNetwork $vmNetwork -SubnetVLan $subnet # bind VLAN with the Network Adapter$vmHost = Get-SCVMHost -ComputerName "VMM01.TESTDOMAIN.net"$vmHostNetworkAdapter = Get-SCVMHostNetworkAdapter -VMHost $vmHost #-Name "Intel 21140-Based PCI Fast Ethernet Adapter (Emulated)"Set-SCVMHostNetworkAdapter -VMHostNetworkAdapter $vmHostNetworkAdapter -Description "" -AvailableForPlacement $true -UsedForManagement $true $logicalNetwork = Get-SCLogicalNetwork -Name "TESTDOMAIN-Service-Network" Set-SCVMHostNetworkAdapter -VMHostNetworkAdapter $vmHostNetworkAdapter -AddOrSetLogicalNetwork $logicalNetworkSet-SCVMHost -VMHost $vmHost -RunAsynchronously -NumaSpanningEnabled $true #Create a Private Cloud$Guid = [System.Guid]::NewGuid()Set-SCCloudCapacity -JobGroup $Guid -UseCustomQuotaCountMaximum $false -UseMemoryMBMaximum $false -UseCPUCountMaximum $false -UseStorageGBMaximum $false -UseVMCountMaximum $false -CustomQuotaCount 10 -MemoryMB 10240 -CPUCount 10 -StorageGB 386 -VMCount 10$resources = @()$resources += Get-SCLogicalNetwork -Name "TESTDOMAIN-Service-Network"$resources += Get-SCLoadBalancer -Manufacturer "Microsoft"$readonlyLibraryShares = @()$readonlyLibraryShares += Get-SCLibraryShare | where { $_.LibraryServer.Name -eq "dc.TESTDOMAIN.net" -and $_.Name -eq "VMMLibrary" }$addCapabilityProfiles = @()$addCapabilityProfiles += Get-SCCapabilityProfile -Name "Hyper-V"$Guid2 = [System.Guid]::NewGuid()Set-SCCloud -JobGroup $Guid2 -RunAsynchronously -AddCloudResource $resources -AddReadOnlyLibraryShare $readonlyLibraryShares -AddCapabilityProfile $addCapabilityProfiles$hostGroups = @()$hostGroups += Get-SCVMHostGroup -Name "TESTDOMAIN"New-SCCloud -VMHostGroup $hostGroups -Name "TESTDOMAIN-Cloud" -Description "" –RunAsynchronously

    Read the article

  • SNTP, why do you mock me?!

    - by Matthew
    --- SOLVED SEE EDIT 5 --- My w2k3 pdc is configured as an authoritative time server. Other servers on the domain are able to sync with it if I manually specify it in the peer list. By if I try to sync from flags 'domhier', it wont resync; I get the error message The computer did not resync because no time data was available. I can only think that it is not querying the pdc. I also tried setting the registry as shown here (http://support.microsoft.com/kb/193825). But no luck (I have not restarted the server, I am hoping I wont have to since it is the pdc) If you would like any further information on my config, please let me know. Edit 1: I have set the w32time service config AnnouceFlags to 0x05 as documented here www.krr.org/microsoft/authoritative_time_servers.php and a number of other places. The PDC syncs to an external time source (ntp). I can get the stripchart on the client from the pdc no problems. The loginserver for the host I am trying to configure is shown as the pdc. Edit 2: The packet capture has revealed something interesting. The client is contacting the correct server, and getting a valid response but I still get the same error message. Here is the NTP excerpt from the client to the server Flags: 11.. .... = Leap Indicator: alarm condition (clock not synchronized) (3) ..01 1... = Version number: NTP Version 3 (3) .... .011 = Mode: client (3) Peer Clock Stratum: unspecified or unavailable (0) Peer Polling Interval: 10 (1024 sec) Peer Clock Precision: 0.015625 sec Root Delay: 0.0000 sec Root Dispersion: 1.0156 sec Reference Clock ID: NULL Reference Clock Update Time: Sep 1, 2010 05:29:39.8170 UTC Originate Time Stamp: NULL Receive Time Stamp: NULL Transmit Time Stamp: Nov 8, 2010 01:44:44.1450 UTC Key ID: DC080000 Here is the reply NTP excerpt from the server to the client Flags: 0x1c 00.. .... = Leap Indicator: no warning (0) ..01 1... = Version number: NTP Version 3 (3) .... .100 = Mode: server (4) Peer Clock Stratum: secondary reference (3) Peer Polling Interval: 10 (1024 sec) Peer Clock Precision: 0.00001 sec Root Delay: 0.1484 sec Root Dispersion: 0.1060 sec Reference Clock ID: 192.189.54.17 Reference Clock Update Time: Nov 8,2010 01:18:04.6223 UTC Originate Time Stamp: Nov 8, 2010 01:44:44.1450 UTC Receive Time Stamp: Nov 8, 2010 01:46:44.1975 UTC Transmit Time Stamp: Nov 8, 2010 01:46:44.1975 UTC Key ID: 00000000 Edit 3: dumpreg for paramters on pdc Value Name Value Type Value Data ------------------------------------------------------------------------ ServiceMain REG_SZ SvchostEntry_W32Time ServiceDll REG_EXPAND_SZ C:\WINDOWS\system32\w32time.dll NtpServer REG_SZ bhvmmgt01.domain.com,0x1 Type REG_SZ AllSync and config Value Name Value Type Value Data -------------------------------------------------------------------------- LastClockRate REG_DWORD 156249 MinClockRate REG_DWORD 155860 MaxClockRate REG_DWORD 156640 FrequencyCorrectRate REG_DWORD 4 PollAdjustFactor REG_DWORD 5 LargePhaseOffset REG_DWORD 50000000 SpikeWatchPeriod REG_DWORD 900 HoldPeriod REG_DWORD 5 LocalClockDispersion REG_DWORD 10 EventLogFlags REG_DWORD 2 PhaseCorrectRate REG_DWORD 7 MinPollInterval REG_DWORD 6 MaxPollInterval REG_DWORD 10 UpdateInterval REG_DWORD 100 MaxNegPhaseCorrection REG_DWORD -1 MaxPosPhaseCorrection REG_DWORD -1 AnnounceFlags REG_DWORD 5 MaxAllowedPhaseOffset REG_DWORD 300 FileLogSize REG_DWORD 10000000 FileLogName REG_SZ C:\Windows\Temp\w32time.log FileLogEntries REG_SZ 0-300 Edit 4: Here are some notables from the ntp log file on the pdc. ReadConfig: failed. Use default one 'TimeJumpAuditOffset'=0x00007080 DomainHierachy: we are now the domain root. ClockDispln: we're a reliable time service with no time source: LS: 0, TN: 864000000000, WAIT: 86400000 Edit 5: F&^%ING SOLVED! Ok so I was reading about people with similar problems, some mentioned w32time server settings applied by GPO, but I tested this early on and there were no settings applied to this service by gpo. Others said that the reporting software may not be picking up some old gpo settings applied. So I searched the registry for all w32time instaces. I came across an interesting key that indicated there may be some other ntp software running on the server. Sure enough, I look through the installed software list and there the little F*&%ER is. Uninstalled and now working like a dream. FFFFFFFUUUUUUUUUUUU

    Read the article

  • Ubuntu Server Cannot Route to the Internet

    - by ejes
    I've been having this problem for weeks now, and I can't seem to figure out the problem. My server can route the local network and serves it well, however it cannot access the internet. It can't be the router because everything else on this lan can route through the router. I've even switched the ethernet port. Any help would be appreciated. I've tried all the usual places, anyway, here are the configs: root@uhs:~# uname -a Linux uhs 3.0.0-16-generic-pae #28-Ubuntu SMP Fri Jan 27 19:24:01 UTC 2012 i686 i686 i386 GNU/Linux root@uhs:~# cat /etc/network/interfaces # This file describes the network interfaces available on your system # and how to activate them. For more information, see interfaces(5). # The loopback network interface auto lo iface lo inet loopback # The primary network interface # auto eth1 # iface eth1 inet dhcp auto eth0 iface eth0 inet static address 192.168.0.3 netmask 255.255.255.0 broadcast 192.168.0.255 gateway 192.168.0.1 root@uhs:~# ping -c 4 192.168.0.1 PING 192.168.0.1 (192.168.0.1) 56(84) bytes of data. 64 bytes from 192.168.0.1: icmp_req=1 ttl=64 time=0.334 ms 64 bytes from 192.168.0.1: icmp_req=2 ttl=64 time=0.339 ms 64 bytes from 192.168.0.1: icmp_req=3 ttl=64 time=0.324 ms 64 bytes from 192.168.0.1: icmp_req=4 ttl=64 time=0.339 ms --- 192.168.0.1 ping statistics --- 4 packets transmitted, 4 received, 0% packet loss, time 2997ms rtt min/avg/max/mdev = 0.324/0.334/0.339/0.006 ms root@uhs:~# ping -c 4 209.85.145.103 PING 209.85.145.103 (209.85.145.103) 56(84) bytes of data. --- 209.85.145.103 ping statistics --- 4 packets transmitted, 0 received, 100% packet loss, time 3023ms root@uhs:~# ifconfig eth0 Link encap:Ethernet HWaddr 00:0c:6e:a0:92:6e inet addr:192.168.0.3 Bcast:192.168.0.255 Mask:255.255.255.0 inet6 addr: fe80::20c:6eff:fea0:926e/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:13131114 errors:0 dropped:0 overruns:0 frame:0 TX packets:10540297 errors:0 dropped:0 overruns:5 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3077922794 (3.0 GB) TX bytes:3827489734 (3.8 GB) Interrupt:10 Base address:0xa000 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:7721 errors:0 dropped:0 overruns:0 frame:0 TX packets:7721 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:551950 (551.9 KB) TX bytes:551950 (551.9 KB) root@uhs:~# route -n Kernel IP routing table Destination Gateway Genmask Flags Metric Ref Use Iface 0.0.0.0 192.168.0.1 0.0.0.0 UG 100 0 0 eth0 192.168.0.0 0.0.0.0 255.255.255.0 U 0 0 0 eth0 root@uhs:~# # PRETEND Traceroute root@uhs:~# for i in {1..30}; do ping -t $i -c 1 209.85.145.103; done | grep "Time to live exceeded" root@uhs:~#

    Read the article

  • WiFi connected to router, but no internet connection

    - by Quetzacotl
    I just got a new notebook, a ThinkPad Edge E530, and installed Ubuntu on it. I'm pretty new to Ubuntu. On the same laptop, running Windows 7, the Wi-Fi connection works fine. Ethernet connection works both on Win7 and on Ubuntu. Only Wi-Fi on Ubuntu does not work; it connects to the Wi-Fi access point but I don't have Internet access. My wireless card is Intel Centrino Wireless-N 2230. What can fix the problem? EDIT: ifconfig -a eth0 Link encap:Ethernet HWaddr b8:88:e3:30:72:34 UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) Interrupt:43 Base address:0x8000 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:163 errors:0 dropped:0 overruns:0 frame:0 TX packets:163 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:10124 (10.1 KB) TX bytes:10124 (10.1 KB) usb0 Link encap:Ethernet HWaddr 02:15:e0:ec:01:00 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) wlan0 Link encap:Ethernet HWaddr 68:5d:43:43:71:e1 inet addr:192.168.2.101 Bcast:192.168.2.255 Mask:255.255.255.0 inet6 addr: fe80::6a5d:43ff:fe43:71e1/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:40 errors:0 dropped:0 overruns:0 frame:0 TX packets:220 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:2801 (2.8 KB) TX bytes:26230 (26.2 KB) route -n Kernel IP routing table Destination Gateway Genmask Flags Metric Ref Use Iface 0.0.0.0 192.168.2.1 0.0.0.0 UG 0 0 0 wlan0 169.254.0.0 0.0.0.0 255.255.0.0 U 1000 0 0 wlan0 192.168.2.0 0.0.0.0 255.255.255.0 U 2 0 0 wlan0 cat /etc/resolv.conf # Dynamic resolv.conf(5) file for glibc resolver(3) generated by resolvconf(8) # DO NOT EDIT THIS FILE BY HAND -- YOUR CHANGES WILL BE OVERWRITTEN nameserver 127.0.0.1 iwconfig lo no wireless extensions. usb0 no wireless extensions. wlan0 IEEE 802.11bgn ESSID:"SATELITE" Mode:Managed Frequency:2.462 GHz Access Point: 00:1F:1F:8D:CC:08 Bit Rate=1 Mb/s Tx-Power=16 dBm Retry long limit:7 RTS thr:off Fragment thr:off Power Management:off Link Quality=60/70 Signal level=-50 dBm Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:93 Invalid misc:243 Missed beacon:0 eth0 no wireless extensions.

    Read the article

  • No client internet access when setting up these iptables rules

    - by Siriss
    I have read many other posts but cannot figure this out. eth0 is my external connected to a Comcast modem. The server has internet access with no issues. eth1 is internal and running DHCP for the clients. I have DHCP working just fine, all my clients can get an IP and ping the server but they cannot access the internet. I am using ISC-DHCP-SERVER and have set /etc/default/isc-dhcp-server to INTERFACE="eht1" Here is my dhcpd.conf file located in /etc/dhcp/dhcpd.conf ddns-update-style interim; ignore client-updates; subnet 10.0.10.0 netmask 255.255.255.0 { range 10.0.10.10 10.0.10.200; option routers 10.0.10.2; option subnet-mask 255.255.255.0; option domain-name-servers 208.67.222.222, 208.67.220.220; #OpenDNS # option domain-name "example.com"; default-lease-time 21600; max-lease-time 43200; authoritative; } I have made the *net.ipv4.ip_forward=1* change in /etc/sysctl.conf here is my interfaces file: auto lo iface lo inet loopback auto eth0 iface eth0 inet dhcp iface eth1 inet static address 10.0.10.2 netmask 255.255.255.0 network 10.0.10.0 auto eth1 And finally- here is my iptables.conf file: # Firewall configuration written by system-config-firewall # Manual customization of this file is not recommended. *nat :PREROUTING ACCEPT [0:0] :OUTPUT ACCEPT [0:0] :POSTROUTING ACCEPT [0:0] -A POSTROUTING -s 10.0.10.0/24 -o eth0 -j MASQUERADE #-A PREROUTING -i eth0 -p tcp --dport 59668 -j DNAT --to-destination 10.0.10.2:59668 COMMIT *filter :INPUT ACCEPT [0:0] :FORWARD ACCEPT [0:0] :OUTPUT ACCEPT [0:0] -A INPUT -m state --state ESTABLISHED,RELATED -j ACCEPT -A INPUT -p icmp -j ACCEPT -A INPUT -i lo -j ACCEPT -A INPUT -i eth1 -j ACCEPT -A INPUT -m state --state NEW -m tcp -p tcp --dport 22 -j ACCEPT -A INPUT -m state --state NEW -m tcp -p tcp --dport 80 -j ACCEPT -A INPUT -m state --state NEW -m tcp -p tcp --dport 443 -j ACCEPT -A INPUT -m state --state NEW -m tcp -p tcp --dport 53 -j ACCEPT -A INPUT -m state --state NEW -m udp -p udp --dport 53 -j ACCEPT -A FORWARD -s 10.0.10.0/24 -o eth0 -j ACCEPT -A FORWARD -d 10.0.10.0/24 -m state --state ESTABLISHED,RELATED -i eth0 -j ACCEPT -A FORWARD -p icmp -j ACCEPT -A FORWARD -i lo -j ACCEPT -A FORWARD -i eth1 -j ACCEPT #-A FORWARD -i eth0 -m state --state NEW -m tcp -p tcp -d 10.0.10.2 --dport 59668 -j ACCEPT -A INPUT -j REJECT --reject-with icmp-host-prohibited -A FORWARD -j REJECT --reject-with icmp-host-prohibited COMMIT I am completely stuck. I cannot figure out why the clients cannot access the internet. Am I missing a service? Is a service not running? Any help would be greatly appreciated. I tried to be as thorough as possible but please let me know if I have missed something. Thank you!

    Read the article

  • My computer freezes irregurarly

    - by Manhim
    My computer started to freeze at irregular times for 3 weeks now. What happens My computer freezes, the video stops. (No graphic glitches, it just stops) Sound keeps playing up to some time (Usually 10-30 seconds) then stops playing. Sometimes, randomly, the screen on my G-15 keyboard flickers and I see caracters not at the right places. Usually happens for about 1-2 seconds and a bit before my computer freezes. I have to keep the power button pressed for 4 seconds to shut my computer down. I still hear my hard drives and fans working. Sometimes it works with no problems for a full day, some other times it just keeps freezing each time I restart my computer and I have to leave it for the rest of the day. Sometimes my mouse freezes for a fraction of a second (Like 0.01 to 0.2 seconds) quite randomly, usually before it freezes. No errors spotted by the "Action center" unlike when I had problems with my last video card on this system (Driver errors). My G-15 LCD screen also freezes. What I did so far I have had similar problems in the past and I had changed my hard drive (It was faulty), so I tested my software RAID-0 array and it was faulty so I changed it. (I reinstalled Windows 7 with this part). I also tested with unplugging my secondary hard drive. My CPU was running at about 100 degree Celsius, I removed the dust between the fans and the heatsink and it's now between 50-60. I ran a CPU stress-test and it didn't freeze during the tests (using Prime95 on all cores) Ran a memory test (using memtest86+) for a single pass and there were no errors. Ran a GPU stress test with ati-tools and furmark and it didn't freeze during the tests. (No artefacts either) I had troubles with my graphic card when I got it, but I think that it got fixed with a driver update. I checked the voltages in my BIOS setup and they all seemed ok (±0.2 I think). I have ran on the computer without problems with Fedora 15 on an external hard drive (Appart that it couldn't load Gnome 3 and was reverting to Gnome 2, didn't want to install drivers since I use it on multiple computers) I used it to backup my files from the raid array to my 1TB hard drive for the reinstallation of Windows. (So the crashes only happenned on Windows) [The external hard drive is plugged directly on a SATA port] I contacted EVGA (My graphic card vendor) and pointed them on this question, I'm looking for an answer. Ran sensors on Fedora 15 and got this output: http://pastebin.com/0BHJnAvu When it happens When I play video games (Mostly) When I play flash games (Second most) When I'm looking at my desktop background (It rarely happens when I have a window open, but it does, sometimes) Specs Windows Seven x64 Home Premium Motherboard: M2N-SLI Deluxe CPU: AMD Phenom 9950 x2 @ 2.6GHz Memory: Kingston 4x2GB Dual Channel (Pretty basic memory sticks) Hard drives: Was 2x250GB (Western digital caviar) in raid-0 + 1TB (WD caviar black), I replaced the raid array with a 750GB (WD caviar black) [Yes I removed the array from the raid configurations] 750W Power supply No overcloking. Ever. There have been some power-downs like 4-5 weeks ago, but the problem didn't start immediately after. (I wasn't home, so my computer got shut-down) My current to-try list Change the thermal paste on my CPU. Change my graphic card with a temporary one and stress the computer. Change my power supply. In this situation, how can I successfully pin-point the current hardware problem? (If it's a hardware problem) Because I don't really have the budget to just forget and replace everything. I also don't really have hardware to test-replace current hardware.

    Read the article

  • Using Network load balancing to distribute load for SharePoint2010 – Part3 of building my own development SharePoint2010 Farm

    - by ybbest
    Part1 of building my own development SharePoint2010 Farm Part2 of building my own development SharePoint2010 Farm Part3 of building my own development SharePoint2010 Farm In my last post, I have installed SharePoint2010 in one of the server (WFE One) and configured using the OOB SharePoint configuration wizard. In this post I will show you how to use OOB windows network load balancing to distribute load for SharePoint2010 site. 1. Install SharePoint in another server WFE Two (you can follow the steps in my last post), but instead of choosing create new Farm, you need to select “connect to existing farm” this time. 2. Click next then click retrieve database names button and select the farm configuration database. 3. Click next and enter the passphrase you specified when you first installed the SharePoint Farm. 4. Click the advanced settings and select Use this machine to host the web site. 5. Click OK to finish the configurations 6. Next, Install NLB in the two WFE (web front end) SharePoint servers 7. Configure NLB to create the cluster. Go to Start—Administrative Tools—Network Load Balancing Manager 8. Right-click the Network Load Balancing Clusters Node and select New Cluster. 9. Type in the host name that is to be part of the new cluster. 10. Type in the IP address for the cluster. 11. Select the Multicast for this cluster.(The default one is Unicast) 12. You can configure the Port Rules for the clustering , but I will leave the default here. 13. Add another WEF to the cluster. 14. Type in the host name that is to be part of the new cluster. 15. Set the Priority to 2. 16. Click Next to complete the cluster setup. 17. Create an entry in the DNS for the new cluster. 18. Add the binding to the IIS site in the IIS Manager 19. Change the Alternate access mapping for you default site collection from http://sp2010wefone to http://team 20. Browse to http://Team , you will be redirected to the SharePoint site.

    Read the article

  • Windows 7 inbuilt and 3rd party (de)fragmentation related queries

    - by Karan
    I have a pretty good idea of how files end up getting fragmented. That said, I just copied ~3,200 files of varying sizes (from a few KB to ~20GB) from an external USB HDD to an internal, freshly formatted (under Windows 7 x64), NTFS, 2TB, 5400RPM, WD, SATA, non-system (i.e. secondary) drive, filling it up 57%. Since it should have been very much possible for each file to have been stored in one contiguous block, I expected the drive to be fragmented not more than 1-2% at most after this rather lengthy exercise (unfortunately this older machine doesn't support USB 3.0). Windows 7's inbuilt defrag utility told me after a quick analysis that the drive was fragmented only 1% or so, which dovetailed neatly with my expectations. However, just out of curiosity I downloaded and ran the latest portable x64 version of Piriform's Defraggler, and was shocked to see the drive being reported as being ~85% fragmented! The portable version of Auslogics Disk Defrag also agreed with Defraggler, and both clearly expected to grind away for ~10 hours to completely defragment the drive. 1) How in blazes could the inbuilt and 3rd party defrag utils disagree so badly? I mean, 10-20% variance is probably understandable, but 1% and 85% are miles apart! This Engineering Windows 7 blog post states: In Windows XP, any file that is split into more than one piece is considered fragmented. Not so in Windows Vista if the fragments are large enough – the defragmentation algorithm was changed (from Windows XP) to ignore pieces of a file that are larger than 64MB. As a result, defrag in XP and defrag in Vista will report different amounts of fragmentation on a volume. ... [Please read the entire post so the quote is not taken out of context.] Could it simply be that the 3rd party defrag utils ignore this post-XP change and continue to use analysis algos similar to those XP used? 2) Assuming that the 3rd party utils aren't lying about the real extent of fragmentation (which Windows is downplaying post-XP), how could the files have even got fragmented so badly given they were just copied over afresh to an empty drive? 3) If vastly differing analysis algos explain the yawning gap, which do I believe? I'm no defrag fanatic for sure, but 85% is enough to make me seriously consider spending 10 hours defragging this drive. On the other hand, 1% reported by Windows' own defragger clearly implies that there is no cause for concern and defragging would actually have negative consequences (as per the post). Is Windows' assumption valid and should I just let it be, or will there be any noticeable performance gains after running one of the 3rd party utils for 10 hours straight? 4) I see that out of the box Windows 7 defrag is scheduled to run weekly. Does anyone know whether it defrags every single time, or only if its analysis reveals a fragmentation percentage over a set threshold? If the latter, what is this threshold and can it be changed, maybe via a Registry edit? Thanks for reading through (my first query on this wonderful site!) and for any helpful replies. Also, if you're answering question #3, please keep in mind that any speed increases post defragging with 3rd party utils vis-à-vis Windows' inbuilt program should not include pre-Vista (preferably pre-Win7) examples. Further, examples of programs that made your system boot faster won't help in this case, since this is a non-system drive (although one that'll still be used daily).

    Read the article

  • Dell Latitude E6430 Docking Station + Dual Monitor + Laptop Screen Tri-Monitor setup

    - by Larry
    I have a company issued laptop and docking station as well as two monitors The specifications of the hardware are as follows; Laptop: Latitude E6430 BIOS: A02.00 Processor: i7-3720QM CPU @ 2.60 (8 CPUs) Memory: 4096MB RAM Page file: 1825MB used, 4793MB available DirectX 11 Display Driver/Chip: MVIDIA NVS 5200M DAC: Integrated RAMDAC Aprox Total Memory: 2376 (Above 3 details same for both displays) Current Display Mode (Display 1): 1600x900 Current Display Mode (Display 2): 1440x900 the docking station is a Dell Latitude E6420 Docking Station PR03X Port Replicator and I don't think the monitor model is particularly relevant to resolving this issue but they are both Acer V193Ws The story goes like this; the laptop works fine if I VGA one monitor into the laptop through the vga port on the back of the lefthand side of the laptop I can achieve dual monitor display fine (laptop screen + monitor) if I plug the laptop into the docking station and use the vga port in the back of the docking station I can dual monitor fine (laptop screen + monitor) if I plug the laptop into the docking station, the laptop's lefthand side VGA port no longer seems to function at all I've spoken to internal IT about this issue and they're going to get me some kind of VGA splitter or a DVI-VGA adapter to use with the docking station for the second Acer Monitor, but that isn't going to happen for a few days. So I guess what I'm wondering is; is there any way to continue to use the side VGA port on my laptop while using the docking station VGA port? and as a secondary 'followup' pending resolution of the initial issue with getting both monitors up and running (at the moment I have both monitors on my desk but am just using my laptop screen as one of my dual monitor display with one of the monitors [the one connected to dock]), is there any way to CONTINUE to use my laptop monitor to in effect have a triple monitor display (2 monitors + docked laptop)? I am wondering this because internal IT told me that they were aware of some issues with the particular display drivers in my box and triple monitor displays but weren't really going to look TOO much in-depth into that (which is perfectly understandable) since getting the adapter for the dual monitors up and running was the greater priority within their purview. So this is a two parter; Can I dual monitor using two vga cables with 1 docking station vga port and one laptop vga port? is there a setting that can be tweaked somewhere? because plugging the box into the station seems to make the side port stop working and... Is there any reasonably simple and cost-effective work around (e.g. I am find with shelling out maybe a few dollars out of my own pocket for some hardware or software to make my company box tri-display capable) but if this requires some extensive rebuild or new OSs or doing stuff to the BIOS I'd rather have a straight answer about this being untenable as a slight modification to a (once again) company laptop and stop wasting time looking into it Thanks! and please let me know if you guys need any more details (tech specs or something) to answer this question [EDIT] 2/10/2014 Just an update; turned out it really was just a hardware limitation issue. The old laptop just couldn't hack it. Got a new laptop with a better video card and different monitors from my company and am successfully using a triple display currently (2 monitors + laptop screen)

    Read the article

  • 1000baseT/Full Supported and Advertised but not working!

    - by user11973
    Hello, i'm using a AT3IONT-I motherboard with integrated card. If I ethtool it to 1000 full duplex it wont work! Here is sudo ethtool eth0: Supported ports: [ TP ] Supported link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Full Supports auto-negotiation: Yes Advertised link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Full Advertised pause frame use: Symmetric Receive-only Advertised auto-negotiation: Yes Speed: 100Mb/s Duplex: Full Port: Twisted Pair PHYAD: 0 Transceiver: internal Auto-negotiation: on MDI-X: Unknown Supports Wake-on: pumbg Wake-on: g Current message level: 0x00000033 (51) Link detected: yes here is sudo lshw -C network: *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:04:00.0 logical name: eth0 version: 03 serial: bc:ae:c5:8b:7d:33 size: 100MB/s capacity: 1GB/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8168 driverversion=8.021.00-NAPI duplex=full ip=192.168.0.2 latency=0 link=yes multicast=yes port=twisted pair speed=100MB/s resources: irq:42 ioport:e800(size=256) memory:f8fff000-f8ffffff memory:f8ff8000-f8ffbfff memory:fbff0000-fbffffff And lspci -nn: 00:00.0 Host bridge [0600]: nVidia Corporation MCP79 Host Bridge [10de:0a82] (rev b1) 00:00.1 RAM memory [0500]: nVidia Corporation MCP79 Memory Controller [10de:0a88] (rev b1) 00:03.0 ISA bridge [0601]: nVidia Corporation MCP79 LPC Bridge [10de:0aad] (rev b3) 00:03.1 RAM memory [0500]: nVidia Corporation MCP79 Memory Controller [10de:0aa4] (rev b1) 00:03.2 SMBus [0c05]: nVidia Corporation MCP79 SMBus [10de:0aa2] (rev b1) 00:03.3 RAM memory [0500]: nVidia Corporation MCP79 Memory Controller [10de:0a89] (rev b1) 00:03.5 Co-processor [0b40]: nVidia Corporation MCP79 Co-processor [10de:0aa3] (rev b1) 00:04.0 USB Controller [0c03]: nVidia Corporation MCP79 OHCI USB 1.1 Controller [10de:0aa5] (rev b1) 00:04.1 USB Controller [0c03]: nVidia Corporation MCP79 EHCI USB 2.0 Controller [10de:0aa6] (rev b1) 00:06.0 USB Controller [0c03]: nVidia Corporation MCP79 OHCI USB 1.1 Controller [10de:0aa7] (rev b1) 00:06.1 USB Controller [0c03]: nVidia Corporation MCP79 EHCI USB 2.0 Controller [10de:0aa9] (rev b1) 00:08.0 Audio device [0403]: nVidia Corporation MCP79 High Definition Audio [10de:0ac0] (rev b1) 00:09.0 PCI bridge [0604]: nVidia Corporation MCP79 PCI Bridge [10de:0aab] (rev b1) 00:0b.0 RAID bus controller [0104]: nVidia Corporation MCP79 RAID Controller [10de:0abc] (rev b1) 00:0c.0 PCI bridge [0604]: nVidia Corporation MCP79 PCI Express Bridge [10de:0ac4] (rev b1) 00:10.0 PCI bridge [0604]: nVidia Corporation MCP79 PCI Express Bridge [10de:0aa0] (rev b1) 00:15.0 PCI bridge [0604]: nVidia Corporation MCP79 PCI Express Bridge [10de:0ac6] (rev b1) 03:00.0 VGA compatible controller [0300]: nVidia Corporation ION VGA [10de:087d] (rev b1) 04:00.0 Ethernet controller [0200]: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller [10ec:8168] (rev 03) If i use Code: sudo ethtool -s eth0 speed 1000 duplex full autoneg off then in ethtool speed is Unknown and it doesn't work; if I set it via pre-up it wont work either... Please help!! Thanks!

    Read the article

  • Restoring databases to a set drive and directory

    - by okeofs
     Restoring databases to a set drive and directory Introduction Often people say that necessity is the mother of invention. In this case I was faced with the dilemma of having to restore several databases, with multiple ‘ndf’ files, and having to restore them with different physical file names, drives and directories on servers other than the servers from which they originated. As most of us would do, I went to Google to see if I could find some code to achieve this task and found some interesting snippets on Pinal Dave’s website. Naturally, I had to take it further than the code snippet, HOWEVER it was a great place to start. Creating a temp table to hold database file details First off, I created a temp table which would hold the details of the individual data files within the database. Although there are a plethora of fields (within the temp table below), I utilize LogicalName only within this example. The temporary table structure may be seen below:   create table #tmp ( LogicalName nvarchar(128)  ,PhysicalName nvarchar(260)  ,Type char(1)  ,FileGroupName nvarchar(128)  ,Size numeric(20,0)  ,MaxSize numeric(20,0), Fileid tinyint, CreateLSN numeric(25,0), DropLSN numeric(25, 0), UniqueID uniqueidentifier, ReadOnlyLSN numeric(25,0), ReadWriteLSN numeric(25,0), BackupSizeInBytes bigint, SourceBlocSize int, FileGroupId int, LogGroupGUID uniqueidentifier, DifferentialBaseLSN numeric(25,0), DifferentialBaseGUID uniqueidentifier, IsReadOnly bit, IsPresent bit,  TDEThumbPrint varchar(50) )    We now declare and populate a variable(@path), setting the variable to the path to our SOURCE database backup. declare @path varchar(50) set @path = 'P:\DATA\MYDATABASE.bak'   From this point, we insert the file details of our database into the temp table. Note that we do so by utilizing a restore statement HOWEVER doing so in ‘filelistonly’ mode.   insert #tmp EXEC ('restore filelistonly from disk = ''' + @path + '''')   At this point, I depart from what I gleaned from Pinal Dave.   I now instantiate a few more local variables. The use of each variable will be evident within the cursor (which follows):   Declare @RestoreString as Varchar(max) Declare @NRestoreString as NVarchar(max) Declare @LogicalName  as varchar(75) Declare @counter as int Declare @rows as int set @counter = 1 select @rows = COUNT(*) from #tmp  -- Count the number of records in the temp                                    -- table   Declaring and populating the cursor At this point I do realize that many people are cringing about the use of a cursor. Being an Oracle professional as well, I have learnt that there is a time and place for cursors. I would remind the reader that the data that will be read into the cursor is from a local temp table and as such, any locking of the records (within the temp table) is not really an issue.   DECLARE MY_CURSOR Cursor  FOR  Select LogicalName  From #tmp   Parsing the logical names from within the cursor. A small caveat that works in our favour,  is that the first logical name (of our database) is the logical name of the primary data file (.mdf). Other files, except for the very last logical name, belong to secondary data files. The last logical name is that of our database log file.   I now open my cursor and populate the variable @RestoreString Open My_Cursor  set @RestoreString =  'RESTORE DATABASE [MYDATABASE] FROM DISK = N''P:\DATA\ MYDATABASE.bak''' + ' with  '   We now fetch the first record from the temp table.   Fetch NEXT FROM MY_Cursor INTO @LogicalName   While there are STILL records left within the cursor, we dynamically build our restore string. Note that we are using concatenation to create ‘one big restore executable string’.   Note also that the target physical file name is hardwired, as is the target directory.   While (@@FETCH_STATUS <> -1) BEGIN IF (@@FETCH_STATUS <> -2) -- As long as there are no rows missing select @RestoreString = case  when @counter = 1 then -- This is the mdf file    @RestoreString + 'move  N''' + @LogicalName + '''' + ' TO N’’X:\DATA1\'+ @LogicalName + '.mdf' + '''' + ', '   -- OK, if it passes through here we are dealing with an .ndf file -- Note that Counter must be greater than 1 and less than the number of rows.   when @counter > 1 and @counter < @rows then -- These are the ndf file(s)    @RestoreString + 'move  N''' + @LogicalName + '''' + ' TO N’’X:\DATA1\'+ @LogicalName + '.ndf' + '''' + ', '   -- OK, if it passes through here we are dealing with the log file When @LogicalName like '%log%' then    @RestoreString + 'move  N''' + @LogicalName + '''' + ' TO N’’X:\DATA1\'+ @LogicalName + '.ldf' +'''' end --Increment the counter   set @counter = @counter + 1 FETCH NEXT FROM MY_CURSOR INTO @LogicalName END   At this point we have populated the varchar(max) variable @RestoreString with a concatenation of all the necessary file names. What we now need to do is to run the sp_executesql stored procedure, to effect the restore.   First, we must place our ‘concatenated string’ into an nvarchar based variable. Obviously this will only work as long as the length of @RestoreString is less than varchar(max) / 2.   set @NRestoreString = @RestoreString EXEC sp_executesql @NRestoreString   Upon completion of this step, the database should be restored to the server. I now close and deallocate the cursor, and to be clean, I would also drop my temp table.   CLOSE MY_CURSOR DEALLOCATE MY_CURSOR GO   Conclusion Restoration of databases on different servers with different physical names and on different drives are a fact of life. Through the use of a few variables and a simple cursor, we may achieve an efficient and effective way to achieve this task.

    Read the article

  • Issues with LVM partition size in Server 13.04

    - by Michael
    I am new to ubuntu and a little confused about how hard drive partitions and LVM works. I remember setting up Ubuntu server 13.04 and telling to to use 1TB of a 3TB server. Well I have maxed that out with blu-ray rips and want the rest of the drive for space. On log-in it says: System load: 2.24 Processes: 179 Usage of /: 88.7% of 912.89GB Users logged in: 0 Memory usage: 6% IP address for p5p1: 192.168.0.100 Swap usage: 0% => / is using 88.7% of 912.89GB lvdisplay outputs: --- Logical volume --- LV Path /dev/DeathStar-vg/root LV Name root VG Name DeathStar-vg LV Write Access read/write LV Creation host, time DeathStar, 2013-05-18 22:21:11 -0400 LV Status available # open 1 LV Size 2.70 TiB Current LE 707789 Segments 2 Allocation inherit Read ahead sectors auto - currently set to 256 Block device 252:0 --- Logical volume --- LV Path /dev/DeathStar-vg/swap_1 LV Name swap_1 VG Name DeathStar-vg LV Write Access read/write LV Creation host, time DeathStar, 2013-05-18 22:21:11 -0400 LV Status available # open 2 LV Size 3.75 GiB Current LE 959 Segments 1 Allocation inherit Read ahead sectors auto - currently set to 256 Block device 252:1 vgdisplay outputs: VG Name DeathStar-vg System ID Format lvm2 Metadata Areas 1 Metadata Sequence No 4 VG Access read/write VG Status resizable MAX LV 0 Cur LV 2 Open LV 2 Max PV 0 Cur PV 1 Act PV 1 VG Size 2.73 TiB PE Size 4.00 MiB Total PE 715335 Alloc PE / Size 708748 / 2.70 TiB Free PE / Size 6587 / 25.73 GiB df outputs: Filesystem 1K-blocks Used Available Use% Mounted on /dev/mapper/DeathStar--vg-root 957238932 848972636 59634696 94% / none 4 0 4 0% /sys/fs/cgroup udev 1864716 4 1864712 1% /dev tmpfs 374968 1060 373908 1% /run none 5120 4 5116 1% /run/lock none 1874824 148 1874676 1% /run/shm none 102400 24 102376 1% /run/user /dev/sda2 234153 56477 165184 26% /boot And fdisk /dev/sda -l outputs: Disk /dev/sda: 3000.6 GB, 3000592982016 bytes 255 heads, 63 sectors/track, 364801 cylinders, total 5860533168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0x00000000 Device Boot Start End Blocks Id System /dev/sda1 1 4294967295 2147483647+ ee GPT Partition 1 does not start on physical sector boundary. I just don't know what to make of all this and am not sure how I can make it use all 2.73TBs. Thanks in advance for any help. EDIT-- Yes I did make changes to the LVM Config, but it didnt do anything. As requested, output of parted -l /dev/sda Model: ATA WDC WD30EFRX-68A (scsi) Disk /dev/sda: 3001GB Sector size (logical/physical): 512B/4096B Partition Table: gpt Number Start End Size File system Name Flags 1 1049kB 2097kB 1049kB bios_grub 2 2097kB 258MB 256MB ext2 3 258MB 3001GB 3000GB lvm Model: ATA WDC WD30EFRX-68A (scsi) Disk /dev/sdb: 3001GB Sector size (logical/physical): 512B/4096B Partition Table: msdos Number Start End Size Type File system Flags Model: Linux device-mapper (linear) (dm) Disk /dev/mapper/DeathStar--vg-swap_1: 4022MB Sector size (logical/physical): 512B/4096B Partition Table: loop Number Start End Size File system Flags 1 0.00B 4022MB 4022MB linux-swap(v1) Model: Linux device-mapper (linear) (dm) Disk /dev/mapper/DeathStar--vg-root: 2969GB Sector size (logical/physical): 512B/4096B Partition Table: loop Number Start End Size File system Flags 1 0.00B 2969GB 2969GB ext4

    Read the article

  • Reading a ZFS USB drive with Mac OS X Mountain Lion

    - by Karim Berrah
    The problem: I'm using a MacBook, mainly with Solaris 11, but something with Mac OS X (ML). The only missing thing is that Mac OS X can't read my external ZFS based USB drive, where I store all my data. So, I decided to look for a solution. Possible solution: I decided to use VirtualBox with a Solaris 11 VM as a passthrough to my data. Here are the required steps: Installing a Solaris 11 VM Install VirtualBox on your Mac OS X, add the extension pack (needed for USB) Plug your ZFS based USB drive on your Mac, ignore it when asked to initialize it. Create a VM for Solaris (bridged network), and before installing it, create a USB filter (in the settings of your Vbox VM, go to Ports, then USB, then add a new USB filter from the attached device "grey usb-connector logo with green plus sign")  Install a Solaris 11 VM, boot it, and install the Guest addition check with "ifconfg -a" the IP address of your Solaris VM Creating a path to your ZFS USB drive In MacOS X, use the "Disk Utility" to unmount the USB attached drive, and unplug the USB device. Switch back to VirtualBox, select the top of the window where your Solaris 11 is running plug your ZFS USB drive, select "ignore" if Mac OS invite you to initialize the disk In the VirtualBox VM menu, go to "Devices" then "USB Devices" and select from the dropping menu your "USB device" Connection your Solaris VM to the USB drive Inside Solaris, you might now check that your device is accessible by using the "format" cli command If not, repeat previous steps Now, with root privilege, force a zpool import -f myusbdevicepoolname because this pool was created on another system check that you see your new pool with "zpool status" share your pool with NFS: share -F NFS /myusbdevicepoolname Accessing the USB ZFS drive from Mac OS X This is the easiest step: access an NFS share from mac OS Create a "ZFSdrive" folder on your MacOS desktop from a terminal under mac OS: mount -t nfs IPadressofMySoalrisVM:/myusbdevicepoolname  /Users/yourusername/Desktop/ZFSdrive et voila ! you might access your data, on a ZFS USB drive, directly from your Mountain Lion Desktop. You might play with the share rights in order to alter any read/write rights as needed. You might activate compression, encryption inside the Solaris 11 VM ...

    Read the article

  • Will you share your SQL Server configuration?

    - by Bill Graziano
    I regularly visit client sites and review their SQL Server configurations.  I come across all kinds of strange settings.  I’ve been thinking about a way to aggregate people’s configurations and see what’s common and what’s unique.  I used to do that with polls on SQLTeam.com.  I think we can find out more interesting things if we look at combinations of settings in relation to size and volume. I’ve been working on an application for another project that is similar.  It will be fairly easy to use that code for this.  I can have something up and running in a few days – if people are interested in it.  I admit that I often come up with ideas that just don’t make sense.  This may be one of them.  One of your biggest concerns has be how secure your data is.  My solution is not to store anything identifying.  The instance name and database names can both be “anonymized” and I don’t store the machine name or IP address or anything to do with logins. Some of the questions I’m curious about are: At what size database does the Enterprise Edition become prevalent? Given the total size of the databases how much RAM is common? How many people have multiple data files?  At what size does that become prevalent? How common is database mirroring?  Replication?  Log shipping? How common is full recovery mode?  At what data size does it become prevalent? I think those are all questions that are easy to answer -- with the right data.  The big question is whether or not people will share their SQL Server configurations.  I understand that organizations in regulated or high security environments can’t participate.  But I think that leaves many, many people that can.  Are you willing to share your configuration and learn about others?  I have a simple sign up form here.  It’s actually a mailing list signup that also captures your edition, number of servers and largest database.  The list will only be used for this project.  Is your SQL Server is configured correctly?  Do you wonder what the next step is as your data grows?  Take a second and sign up.

    Read the article

  • Problems with XP, Office, and PC in general - any ideas?

    - by molecule
    Hi all This may not make a whole lot of sense so pls bear with me... I am about to perform a routine check on one of my user's PC. Some background - the PC has a Xeon processor and 4Gb of RAM and running XP SP3 He has 2xHDD and pagefile is hosted on the secondary HDD (D:) and min/max values are set to 4096. NO pagefile on C: This user has 6 monitors so he has an NVIDIA Quadro NVS440 hosting 4xmonitors and an NVIDIA Quadro NVS290 hosting 2xmonitors. There is a video card driver from NVIDIA which is compatible with both NVS440 and NVS290 and he is on the latest version of that driver. (Note: Make of video cards are different - one is from leadtek and the other from Nvidia) He is a heavy Bloomberg, Outlook, Word, and Excel user and runs two Citrix applications. Other apps are FoxIt PDF and IE. Problems - Outlook and Excel frequently crashes - I am going to perform an Outlook and Excel repair and also check/remove unnecessary addins - will he lose any customizations if I repaired and chose "Restore my shortcuts while repairing" and do not select "Discard my customized settings and restore default settings". Does repair really repair anything? FYI - It stopped crashing ever since i moved a large spreadsheet he has open to his local HDD instead of over the network. This spreadsheet "refreshes" constantly as it is pulling live data to update cells and I suspect it was auto-saving so frequently that it caused crashes if saving over the network. At times, his right click completely fails to respond. His left click works fine but he can't right click on anything in any Window and even on the desktop. Sometimes, he needs to start to close certain applications such as Adobe and the right click will start functioning again. I removed Adobe and installed FoxIt as I figured it was a resource issue but I do not think so as he does have sufficient resources when the problem is happening. Sometimes he can't bring task manager up until he kills certain apps. Definitely sounds like a resource issue but I am not confident that is the root cause. Also not sure if this is related to one of the apps installed but his Start bar flickers (does not completely disappear) intermittently from time to time. The taskbar icons which are hidden appear and then get hidden again as if it was having "fits". I have performed reg scans, malware scans etc but problems do not go away. I am planning to perform sfc /scannow and office repair but would like to know if anyone has any other suggestions. What about setting a "small" pagefile on C:. I have heard that this is recommended and may be the reason why a minidmp file was not generated when he encountered a blue screen. Also, any feedback on his video cards? Do you think different models would cause problems? The drivers seem to work but he only has 2.5Gb out of 4Gb available RAM as I believe the video card chomped up a portion of this. I have recommended creating a new profile for him but due to the amount of customisations he has and the amount of time and effort it will take to get him up and running again, he prefers to bear with the problem than to go down that path. However, at least once a week, his PC acts up and I can't think of any other tools or techniques to rectify his problems. I guess we are at a stage where we just want to "stabilize" things so he won't encounter issues that frequently. Any feedback is very much appreciated.

    Read the article

  • determine if udp socket can be accessed via external client

    - by JohnMerlino
    I don't have access to company firewall server. but supposedly the port 1720 is open on my one ubuntu server. So I want to test it with netcat: sudo nc -ul 1720 The port is listening on the machine ITSELF: sudo netstat -tulpn | grep nc udp 0 0 0.0.0.0:1720 0.0.0.0:* 29477/nc The port is open and in use on the machine ITSELF: lsof -i -n -P | grep 1720 gateway 980 myuser 8u IPv4 187284576 0t0 UDP *:1720 Checked the firewall on current server: sudo ufw allow 1720/udp Skipping adding existing rule Skipping adding existing rule (v6) sudo ufw status verbose | grep 1720 1720/udp ALLOW IN Anywhere 1720/udp ALLOW IN Anywhere (v6) But I try echoing data to it from another computer (I replaced the x's with the real integers): echo "Some data to send" | nc xx.xxx.xx.xxx 1720 But it didn't write anything. So then I try with telnet from the other computer as well: telnet xx.xxx.xx.xxx 1720 Trying xx.xxx.xx.xxx... telnet: connect to address xx.xxx.xx.xxx: Operation timed out telnet: Unable to connect to remote host Although I don't think telnet works with udp sockets. I ran nmap from another computer within the same local network and this is what I got: sudo nmap -v -A -sU -p 1720 xx.xxx.xx.xx Starting Nmap 5.21 ( http://nmap.org ) at 2013-10-31 15:41 EDT NSE: Loaded 36 scripts for scanning. Initiating Ping Scan at 15:41 Scanning xx.xxx.xx.xx [4 ports] Completed Ping Scan at 15:41, 0.10s elapsed (1 total hosts) Initiating Parallel DNS resolution of 1 host. at 15:41 Completed Parallel DNS resolution of 1 host. at 15:41, 0.00s elapsed Initiating UDP Scan at 15:41 Scanning xtremek.com (xx.xxx.xx.xx) [1 port] Completed UDP Scan at 15:41, 0.07s elapsed (1 total ports) Initiating Service scan at 15:41 Initiating OS detection (try #1) against xtremek.com (xx.xxx.xx.xx) Retrying OS detection (try #2) against xtremek.com (xx.xxx.xx.xx) Initiating Traceroute at 15:41 Completed Traceroute at 15:41, 0.01s elapsed NSE: Script scanning xx.xxx.xx.xx. NSE: Script Scanning completed. Nmap scan report for xtremek.com (xx.xxx.xx.xx) Host is up (0.00013s latency). PORT STATE SERVICE VERSION 1720/udp closed unknown Too many fingerprints match this host to give specific OS details Network Distance: 1 hop TRACEROUTE (using port 1720/udp) HOP RTT ADDRESS 1 0.13 ms xtremek.com (xx.xxx.xx.xx) Read data files from: /usr/share/nmap OS and Service detection performed. Please report any incorrect results at http://nmap.org/submit/ . Nmap done: 1 IP address (1 host up) scanned in 2.04 seconds Raw packets sent: 27 (2128B) | Rcvd: 24 (2248B). The only thing I can think of is a firewall or vpn issue. Is there anything else I can check for before requesting that they look at the firewall server again?

    Read the article

  • Best way to remote restart Ubuntu from Windows machine

    - by robsoft
    Background: I'm looking to put a series of Ubuntu machines into retail locations, they're being used as dumb kiosks to show a series of slides onto large LCD panel TV screens. Once installed, they won't have a keyboard or mouse connected but will have a fixed IP on the local network. Everything is configured to auto-start, no automatic updates, no power saving etc - I think we're pretty-much good to go apart from one thing. I need the retail staff to be able to restart the boxes if a problem arises. We have VNC running (now that we've turned off desktop enhancements!) so that we can remotely get into the machines if we need to, but that's not something we would allow the retail staff to do. The machines are going to be physically 'out of the way' (probably in the ceiling space) so the power button is not easily accessible!. I'd like to have some means of allowing the retail staff to restart the Ubuntu machine, from the desktop of one of their Windows terminals. I don't really want to give them some kind of raw terminal access (the command line will frighten them!) and I don't want them to use VNC (as stated above). Ideally there would be an icon on the Windows desktop, they double-click it, reply to a simple 'are you sure?' prompt, and then the Ubuntu box is told to restart. The Windows side of that won't be a problem, we can write something using Delphi, Python & Qt4, whatever - it's the Ubuntu side of it I'm stuck with. Out of sight/view, could I have a Windows program open a terminal across the network and tell Ubuntu to restart? Is this what SSH could be used for (I have never set that kind of thing up). The Windows programming side isn't really an issue, it's just that I'm a total Ubuntu noob and don't know where to start from the platform point of view. The other thing we considered is also having the machine automatically restart itself at a set time each day (obviously out of store hours!). To me, that seems a bit unnecessary (though forcing a restart once a week/month might be worthwhile). Any thoughts or suggestions? Being able to restart the box on demand across the network is my prime requirement.

    Read the article

  • What is SOA ?

    - by llaszews
    First, let’s mention what SOA is not: • SOA is not the same thing as web services. Web Services implies the use of standard such as Java/JAX-RPC, .NET or REST. Web Services also implies the use of a WSDL, SOAP, and/or J2EE Connector Architecture (J2EE CA) and HTTP. SOA architectures can be implemented using J2EE CA, XML file transfer or Remote Procedural Call (RPC) over File Transfer Protocol (FTP), TCP/IP, Remote Method Invocation (RMI) or other protocols. In other words, Web Services are a very specific set of technologies. SOA is a concept and can be implemented in many different ways. Some very rudimentary, such as transfering flat files between applications. • SOA will not solve all of your problems. It will make your business more agile, increase business visibility, reduce integration costs and provide better reuse. However, if you don’t need help in these area or expect SOA to cure all of your IT problems, you are looking in the wrong place. • The concepts behind SOA are not new, but SOA is also not mature. SOA as it stands today has really only been around for 5 years. The concepts of standards based protocol handlers, predefined communication schemas and remote method invocation have been around for decades. So, what is SOA? SOA is an architectural blueprint, a way of developing applications, and a set of best practices. SOA is not an ‘out of the box’ solution you buy, install and then have up and running in a matter of months. SOA is a journey to a better way of doing business and the technology architecture to support this better way of doing business. SOA is also a broader set of technologies including more then just web services. Techologies like an Enterpirse Service Bus (ESB), Business Processs Execution Language (BPEL), message queues and Business Activity Monitoring (BAM) all are part of a SOA architecture. So, what is SOA? SOA is an architectural blueprint, a way of developing applications, and a set of best practices. SOA is not an ‘out of the box’ solution you buy, install and then have up and running in a matter of months. SOA is a journey to a better way of doing business and the technology architecture to support this better way of doing business. SOA is also a broader set of technologies including more then just web services. Techologies like an Enterpirse Service Bus (ESB), Business Processs Execution Language (BPEL), message queues and Business Activity Monitoring (BAM) all are part of a SOA architecture. Read more here: Oracle Modernization Solutions

    Read the article

  • sony vaio WLAN problem using 12.04

    - by Fredrik
    I'm unable to get my WLAN to work for my Sony Vaio model VPCF23C5E No problem connecting from windows, smartphones etc. $ sudo lshw -C network; lsb_release -a; uname -a; sudo rfkill list; dmesg | grep -i firm *-network description: Wireless interface product: AR9485 Wireless Network Adapter vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:02:00.0 logical name: wlan0 version: 01 serial: 64:27:37:92:99:0f width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list rom ethernet physical wireless configuration: broadcast=yes driver=ath9k driverversion=3.2.0-29-generic firmware=N/A latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:16 memory:f7000000-f707ffff memory:f7080000-f708ffff *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:05:00.0 logical name: eth0 version: 06 serial: f0:bf:97:dd:b2:bd size: 1Gbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl_nic/rtl8168e-1.fw ip=192.168.1.4 latency=0 link=yes multicast=yes port=MII speed=1Gbit/s resources: irq:50 ioport:9000(size=256) memory:e2104000-e2104fff memory:e2100000-e2103fff LSB Version: core-2.0-amd64:core-2.0-noarch:core-3.0-amd64:core-3.0-noarch:core-3.1-amd64:core-3.1-noarch:core-3.2-amd64:core-3.2-noarch:core-4.0-amd64:core-4.0-noarch Distributor ID: Ubuntu Description: Ubuntu 12.04.1 LTS Release: 12.04 Codename: precise Linux siriedit 3.2.0-29-generic #46-Ubuntu SMP Fri Jul 27 17:03:23 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux 1: phy0: Wireless LAN Soft blocked: no Hard blocked: no 2: hci0: Bluetooth Soft blocked: no Hard blocked: no [ 1.287449] [Firmware Bug]: ACPI: BIOS _OSI(Linux) query ignored [ 18.273582] [Firmware Bug]: ACPI(NGFX) defines _DOD but not _DOS Seen some proposed solution e.g. Wireless network cannot be enabled for Sony VAIO E series but answers there don't solve my problem... I'm out of ideas :-( What else can I check? update $ ifconfig -a eth0 Link encap:Ethernet HWaddr f0:bf:97:dd:b2:bd inet addr:192.168.1.4 Bcast:192.168.1.255 Mask:255.255.255.0 inet6 addr: fe80::f2bf:97ff:fedd:b2bd/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:5072 errors:0 dropped:0 overruns:0 frame:0 TX packets:4444 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:4568435 (4.5 MB) TX bytes:610624 (610.6 KB) Interrupt:50 Base address:0xc000 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:1498 errors:0 dropped:0 overruns:0 frame:0 TX packets:1498 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:114156 (114.1 KB) TX bytes:114156 (114.1 KB) wlan0 Link encap:Ethernet HWaddr 64:27:37:92:99:0f inet addr:192.168.1.5 Bcast:192.168.1.255 Mask:255.255.255.0 inet6 addr: fe80::6627:37ff:fe92:990f/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1277 errors:0 dropped:0 overruns:0 frame:0 TX packets:472 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:483155 (483.1 KB) TX bytes:61031 (61.0 KB)

    Read the article

  • Setting up home DNS with Ubuntu Server

    - by Zeophlite
    I have a webserver (with static IP 192.168.1.5), and I want to have my machines on my local network to be able to access it without modifying /etc/hosts (or equivalent for Windows/OSX). My router has Primary DNS server 192.168.1.5 Secondary DNS server 8.8.8.8 (Google's public DNS). Nginx is set up to server websites externally as *.example.com Internally, I want *.example.local to point to the server. My webserver has BIND9 installed, but I'm unsure of the settings. I've been through various contradicting tutorials, and so most of my settings have been clobbered. I've stripped out the lines which I'm confused about. The tutorials I looked at are http://tech.surveypoint.com/blog/installing-a-local-dns-server-behind-a-hardware-router/ and http://ubuntuforums.org/showthread.php?t=236093 . They mostly differ on what should be put in /etc/bind/zones/db.example.local and /etc/bind/zones/db.192, so I've left the conflicting lines out below. Can someone suggest what the correct lines are to give my above behaviour (namely *.example.local pointing to 192.168.1.5)? /etc/network/interfaces auto lo iface lo inet loopback auto eth0 iface eth0 inet static address 192.168.1.5 netmask 255.255.255.0 broadcast 192.168.1.255 gateway 192.168.1.254 /etc/hostname avalon /etc/resolv.conf # Dynamic resolv.conf(5) file for glibc resolver(3) generated by resolvconf(8) # DO NOT EDIT THIS FILE BY HAND -- YOUR CHANGES WILL BE OVERWRITTEN /etc/bind/named.conf.options options { directory "/var/cache/bind"; forwarders { 8.8.8.8; 8.8.4.4; }; dnssec-validation auto; auth-nxdomain no; # conform to RFC1035 listen-on-v6 { any; }; }; /etc/bind/named.conf.local zone "example.local" { type master; file "/etc/bind/zones/db.example.local"; }; zone "1.168.192.in-addr.arpa" { type master; file "/etc/bind/zones/db.192"; }; /etc/bind/zones/db.example.local $TTL 604800 @ IN SOA avalon.example.local. webadmin.example.local. ( 5 ; Serial, increment each edit 604800 ; Refresh 86400 ; Retry 2419200 ; Expire 604800 ) ; Negative Cache TTL /etc/bind/zones/db.192 $TTL 604800 @ IN SOA avalon.example.local. webadmin.example.local. ( 4 ; Serial, increment each edit 604800 ; Refresh 86400 ; Retry 2419200 ; Expire 604800 ) ; Negative Cache TTL ; What do I need to add to the above files so that on a laptop on the internal network, I can type in webapp.example.local, and be served by my webserver? EDIT I made several changes to the above files on the webserver. /etc/network/interfaces (end of file) dns-nameservers 127.0.0.1 dns-search example.local /etc/bind/zones/db.example.local (end of file) @ IN NS avalon.example.local. @ IN A 192.168.1.5 avalon IN A 192.168.1.5 webapp IN A 192.168.1.5 www IN CNAME 192.168.1.5 /etc/bind/zones/db.192 (end of file) IN NS avalon.example.local. 73 IN PTR avalon.example.local. As a side note, my spare Win7 machine was able to connect directly to webapp.example.local, but for a Ubuntu 13.10 machine, I had to make the following changes as well (not on the webserver, but on a separate machine): /etc/nsswitch.conf before hosts: files mdns4_minimal [NOTFOUND=return] dns mdns4 after hosts: files dns /etc/NetworkManager/NetworkManager.conf before dns=dnsmasq after #dns=dnsmasq The issue remains that its not wildcard DNS, and so I have to add entries to /etc/bind/zones/db.example.local for webapp1, webapp2, ...

    Read the article

  • JCP.next.3: time to get to work

    - by Patrick Curran
    As I've previously reported in this blog, we planned three JSRs to improve the JCP’s processes and to meet our members’ expectations for change. The first - JCP.next.1, or more formally JSR 348: Towards a new version of the Java Community Process - was completed in October 2011. This focused on a small number of simple but important changes to make our process more transparent and to enable broader participation. We're already seeing the benefits of these changes as new and existing JSRs adopt the new requirements. However, because we wanted to complete this JSR quickly we deliberately postponed a number of more complex items, including everything that would require modifying the JSPA (the legal agreement that members sign when they join the organization) to a follow-on JSR. The second JSR (JSR 355: JCP Executive Committee Merge) is in progress now and will complete later this year. This JSR is even simpler than the first, and is focused solely on merging the two Executive Committees into one for greater efficiency and to encourage synergies between the Java ME and Java SE platforms. Continuing the momentum to move Java and the JCP forward we have just filed the third JSR (JCP.next.3) as JSR 358: A major revision of the Java Community Process. This JSR will modify the JSPA as well as the Process Document, and will tackle a large number of complex issues, many of them postponed from JSR 348. For these reasons we expect to spend a considerable amount of time working on it - at least a year, and probably more. The current version of the JSPA was created back in 2002, although some minor changes were introduced in 2005. Since then the organization and the environment in which we operate have changed significantly, and it is now time to revise our processes to ensure that they meet our current needs. We have a long list of topics to be considered, including the role of independent implementations (those not derived from the Reference Implementation), licensing and open source, ensuring that our new transparency requirements are implemented correctly, compatibility policy and TCKs, the role of individual members, patent policy, and IP flow. The Expert Group for JSR 358, as with all process-change JSRs, consists of all members of the Executive Committees. Even though the JSR has just been filed we started discussions on the various topics several months ago (see the EC's meeting minutes for details) and our EC members - including the new members who joined within the last year or two - are actively engaged. Now it's your opportunity to get involved. As required by version 2.8 of our Process (introduced with JSR 348) we will conduct all our business in the open. We have a public java.net project where you can follow and participate in our work. All of our deliberations will be copied to a public Observer mailing list, we'll track our issues on a public Issue Tracker, and all our documents (meeting agendas and minutes, task lists, working drafts) will be published in our Document Archive. We're just getting started, but we do want your input. Please visit us on java.net where you can learn how to participate. Let's get to work...

    Read the article