  • Cannot run a VM with more than three network interfaces with KVM

    - by Bostonvaulter
    I'm running KVM on top of Ubuntu 10.10 Server I can create VM's (Virtual Machine) and network interfaces fine but I cannot seem to add more than three network interfaces. As soon as I have a VM with four network interfaces it gets stuck on startup at the starting SeaBIOS page with this message: Starting SeaBIOS (version pre-0.6.1-20100702_143500-palmer) So far I've verified this with two VM's, a Ubuntu 10.10 desktop and a Vyatta router. The specific network hardware I assign to the VM's doesn't seem to matter. I'm trying to have one bridged interface and three private networks using Vyatta to route between them. Does anyone know why I can't run a VM with more than three network interfaces? Edit: Additionally the KVM thread responsible for the specific VM hangs using ~100% CPU (i.e. one core). Here's the command for the process that is hanging: /usr/bin/kvm -S -M pc-0.12 -enable-kvm -m 512 -smp 1,sockets=1,cores=1,threads=1 -name vyatta -uuid 6dff7c94-6810-423e-5fea-fec10da0e9b7 -nodefaults -chardev socket,id=monitor,path=/var/lib/libvirt/qemu/vyatta.monitor,server,nowait -mon chardev=monitor,mode=readline -rtc base=utc -boot c -drive file=/home/rams/virtual-machines/vyatta.img,if=none,id=drive-ide0-0-0,boot=on,format=raw -device ide-drive,bus=ide.0,unit=0,drive=drive-ide0-0-0,id=ide0-0-0 -drive if=none,media=cdrom,id=drive-ide0-1-0,readonly=on,format=raw -device ide-drive,bus=ide.1,unit=0,drive=drive-ide0-1-0,id=ide0-1-0 -device rtl8139,vlan=0,id=net0,mac=00:54:00:be:cc:4b,bus=pci.0,addr=0x3 -net tap,fd=97,vlan=0,name=hostnet0 -device rtl8139,vlan=1,id=net1,mac=52:54:00:da:59:ed,bus=pci.0,addr=0x5 -net tap,fd=98,vlan=1,name=hostnet1 -device rtl8139,vlan=2,id=net2,mac=52:54:00:ce:22:b6,bus=pci.0,addr=0x6 -net tap,fd=99,vlan=2,name=hostnet2 -device rtl8139,vlan=3,id=net3,mac=52:54:00:1e:bc:46,bus=pci.0,addr=0x7 -net tap,fd=101,vlan=3,name=hostnet3 -chardev pty,id=serial0 -device isa-serial,chardev=serial0 -usb -vnc 127.0.0.1:0 -k en-us -vga cirrus -device virtio-balloon-pci,id=balloon0,bus=pci.0,addr=0x4 Edit: I've also found an error in dmesg that might be related (it also shows up when running virtd in verbose mode): 14:47:24.399: warning : qemudParsePCIDeviceStrs:1422 : Unexpected exit status '1', qemu probably failed I've also tried disabling app armor but that doesn't seem to make a difference.

    Read the article

  • DHCP and DNS services configuration for VOIP system, windows domain, etc

    - by Stemen
    My company has numerous physical offices (for purposes of this discussion, 15 buildings). Some of them are well-connected to our primary data center via fiber. Others will be connected to the data center by P2P T1. We are in the beginning stages of implementing an Avaya VOIP telephone system, and we will be replacing a significant portion of our network infrastructure in the process. In tandem with the phone system implementation, we are going to be re-addressing some of our networks, and consolidating most of our Windows domains into one (not all domains, just most). We currently have quite a few Windows domains, and they of course each have their own DNS zones. A few of those networks currently use DHCP, but the majority use static IP assignments for every device. I'm tired of managing static assignments -- I want to use DHCP configuration on everything except servers. Printers and etc will have DHCP reservations. The new IP phones will need to get IP addresses from DHCP, though they need to be in a separate VLAN from the computers/printers/etc. The computers and printers need to be registered in DNS. That's currently handled by the Windows DHCP servers on each of the respective domains. We need to place a priority on DHCP and DNS being available on a per-site basis (in case something were to interrupt the WAN connection) for computers and (primarily) phones. Smaller locations (which will have IP phones but not be a member of any Windows domain) will not have any Windows DNS/DHCP server(s) available. We also are looking for the easiest way to replace a part if it were to fail. That is to say, if a server/appliance/router hosting DHCP were to crash hard, and we couldn't extremely quickly recover the DHCP reservations and leases (and subsequently restore them onto a cold spare), we anticipate that bad things could happen. What is the best idea for how to re-implement DNS and DHCP keeping all of the above in mind? Some thoughts that have been raised (by myself or my coworkers): Use Windows DNS and DHCP servers, where they exist, and use IP helpers to route DHCP requests to some other Windows server if necessary. May not be acceptable if the WAN goes down and clients don't get a DHCP response. Use Windows DNS (everywhere, over WAN in some cases) and a mix of Windows DHCP and DHCP provided by Cisco routers. Every site would be covered for DHCP, but from what I've read, Cisco routers can't handle dynamic registration of DHCP clients to Windows DNS servers, which might create a problem where Cisco routers are used for DHCP. Use Windows DNS (everywhere, over WAN in some cases) and a mix of Windows DHCP and DHCP provided by some service running on an extremely low-price linux server. Is there any such software that would allow DHCP leases granted by these linux boxes to be dynamically registered on the Windows DNS servers? Come up with a Linux solution for both DNS and DHCP, and deploy low-price linux servers to every site. Requirements would be that the DNS zone be multi-master (like Windows DNS integrated with Active Directory), that DHCP be able to make dynamic DNS registrations in that zone, for every lease (where a hostname is provided and is thus possible), and that multiple servers be either authoritative for the same DHCP scope or at least receiving a real-time copy / replication / sync of the leases table so that if one server dies, we still know which MAC has what address. Purchase dedicated DNS/DHCP appliances, deploying to all sites. From what I read/see, this solves all of our technical problems. Then come the financial problems... I don't have a ton of money to spend on this. Or, some other solution that we've thus far overlooked and will consider upon recommendation. Can Cisco routers or Windows servers sync DHCP lease tables so that multiple servers can be authoritative (or active/passive for all I care) for the same scope, in case one of the partners were to fail? I've read online (repeatedly) that ISC's DHCP is able to maintain the same lease table across multiple servers, in order to solve this problem. Does anyone have any experience or advice to regarding that?

    Read the article

  • Windows 7 boot problem (with colorful blinking smilies)

    - by Ishmael Smyrnow
    I put my computer (Windows 7) to sleep, and a couple hours later, tried to wake it back up, but the monitor wouldn't come back on. I did a hard reset (held power button), but I still couldn't get the monitor to show anything. I plugged it into my laptop, and the monitor works fine. I then swapped out the video card with an older one I have. The monitor came on and started showing the boot process. However, shortly after the Windows 7 animated logo came up, the screen went blank, it made this weird beeping noise, and I seen the strangest thing ever. Small, colorful blocks started to fill my screen, and flash, as if something was loading. Inside of those blocks, were smilies (like the ASCII character kind). This continued for about a minute, then the computer rebooted. It scared the sh!t out of me. I've never had a virus before, and I'm savvy enough to keep myself from one, but I'm wondering if that's what it was. I've been using computers for ages, and never seen anything quite like this. Has anyone ever seen something like this? I'm doing hardware diagnostics before trying to boot into Windows again. Hopefully I can figure this out, but I thought I would consult the SU community while I wait on these results. -- UPDATE -- I did a Memory Diagnostic, which turned up nothing. I also booted into Safe Mode no problem, and scheduled a disk check on both of my drives (I dual boot XP & 7). I was feeling good, and tried putting my regular video card back in, and the monitor won't display anything with it. Also, even though the monitor displays nothing, the system sounds like it's booting up. However, I hear a clicking in one of my hard drives that isn't there with the older video card. Could this be a problem with my hard drive, video card, or PSU? PSU makes sense, except for the fact I've been using the same setup for over a year, and the video card doesn't require it's own power plug thing.

    Read the article

  • HP DAT72x6 autoloader

    - by ericmayo
    Hoping someone here has seen this similar issue and can offer soem advise... I have an HP DAT72x6 auto loader tape backup unit. The external kind, here is a link to an owner's manual I found of it. http://www.dectrader.com/docs/set2/emr_na-c00070400-1.pdf I purchased the unit used about 6 months ago. The unit stopped working after 3-4 back-ups, it's used one day a month to do a monthly backup of another system. Suffice it to say the unit gets very little usage. There is an amber light on the front of the unit called the OAR (Operator Attention Required). The manual states to call for service when this light comes on and stays on. I've tried a few things to resolve but none are working. I've tried power cycling, re-securing the SCSI cables at both ends. Unit was used so I didn't pay much ($500) and so I don't want to spend a lot to have it fixed; might as well buy something new one if fixing this is going to cost more than $100-$150 bucks. I'm curious to see if anyone here has been around these devices or possibly is an HP repair person that can give me some things to try to resolve. The manual states that a solid amber OAR light indicates a hardware failure. When I power cycle the unit I see one of two scenarios so far. The unit powers up, shows self test in the LCD, then LCD changes to show all possible images and the OAR light comes on. The unit powers up, LCD is completely blank, the green lights go through some sort of process of going on and off and later the amber OAR light comes on and stays on. If it's a simple misalignment issue, I may be able to fix myself but not knowing what could cause the OAR light to come on gives me no where to even start. Google around gave no help either. I hoping someone here has experience with this and can help or point me in the right direction. Also, I don't have the HP Diagnostic tools mentioned in many manuals. The unit is connected to a Linux box. The 3-4 backups I've done with it so far have had no issues. We run amanda backup. Before this incident the unit was backing up and reading tapes fine. Thanks for any help or suggestions.

    Read the article

  • Why do I see a large performance hit with DRBD?

    - by BHS
    I see a much larger performance hit with DRBD than their user manual says I should get. I'm using DRBD 8.3.7 (Fedora 13 RPMs). I've setup a DRBD test and measured throughput of disk and network without DRBD: dd if=/dev/zero of=/data.tmp bs=512M count=1 oflag=direct 536870912 bytes (537 MB) copied, 4.62985 s, 116 MB/s / is a logical volume on the disk I'm testing with, mounted without DRBD iperf: [ 4] 0.0-10.0 sec 1.10 GBytes 941 Mbits/sec According to Throughput overhead expectations, the bottleneck would be whichever is slower, the network or the disk and DRBD should have an overhead of 3%. In my case network and I/O seem to be pretty evenly matched. It sounds like I should be able to get around 100 MB/s. So, with the raw drbd device, I get dd if=/dev/zero of=/dev/drbd2 bs=512M count=1 oflag=direct 536870912 bytes (537 MB) copied, 6.61362 s, 81.2 MB/s which is slower than I would expect. Then, once I format the device with ext4, I get dd if=/dev/zero of=/mnt/data.tmp bs=512M count=1 oflag=direct 536870912 bytes (537 MB) copied, 9.60918 s, 55.9 MB/s This doesn't seem right. There must be some other factor playing into this that I'm not aware of. global_common.conf global { usage-count yes; } common { protocol C; } syncer { al-extents 1801; rate 33M; } data_mirror.res resource data_mirror { device /dev/drbd1; disk /dev/sdb1; meta-disk internal; on cluster1 { address 192.168.33.10:7789; } on cluster2 { address 192.168.33.12:7789; } } For the hardware I have two identical machines: 6 GB RAM Quad core AMD Phenom 3.2Ghz Motherboard SATA controller 7200 RPM 64MB cache 1TB WD drive The network is 1Gb connected via a switch. I know that a direct connection is recommended, but could it make this much of a difference? Edited I just tried monitoring the bandwidth used to try to see what's happening. I used ibmonitor and measured average bandwidth while I ran the dd test 10 times. I got: avg ~450Mbits writing to ext4 avg ~800Mbits writing to raw device It looks like with ext4, drbd is using about half the bandwidth it uses with the raw device so there's a bottleneck that is not the network.

    Read the article

  • DPM 2010 "Disk failed or disk not found"

    - by SysAdmin
    I have an HP Proliant ML110 G5 server with Windows server 2008R2 only dedicated for DPM 2010. This server has a limit in HD of 8TB which has already been met. I'm now stuck in this situation where my disk keeps failing "Disk failed or Disk not found" in the disk management. Only after I reboot the system the disk comes back up. Today I was running my monthly tape backup on a certain protection group and the disk failed again while the tape job was running (so the job wasn't completed). This is the description of the error in the alerts: "The disk Disk 1 - Hitachi HDS722020ALA330 SCSI Disk Device cannot be detected or has stopped responding. All subsequent protection activities that use this disk will fail until the disk is brought back online. (ID 3120)". My backup system is becoming useless! I don't think that is a hardware issue (please correct me if I'm wrong) since the HD works fine for a certain period of time which is becoming shorter and shorter. I basically have no more option to fix this problem. I tried to fix any error that was coming up in the event viewer with no luck (included one regarding the SQL2008 compatibility issue). The disk keeps failing! Now I'm only trying to recover/migrate the data from the disk that is having problem but my issue now is that I cannot add any drives to my server since I already got installed the maximum storage capacity 8TB. I thought about 2 simple options. Please tell me what you guys think about it; Unplug one of the 2 storage pool disks (disk0, that one without problem) from the machine and install a new one in order to migrate the data with the Migration tool for DPM. Remove the defective disk (disk1), put back the disk0 and run the synchronization/consistency check on all the groups to recreate replicas and recovery points. Run diskpart.exe and clean up the disk (loosing all data) and hoping that he will work after I sync all the protection groups. Both solutions are not elegant but I have no better options at the moment. Please I need some help. Thanks for your time Angelo

    Read the article

  • Problem installing Cardbus/PCMCIA drivers (USB 2.0 2-port)

    - by Carl
    I obtained the drivers from the manufacturer for my HT-Link NEC USB 2.0 2-port Cardbus card. When I plugged in the card before I got the drivers, 3 new entries showed up in the Device Manager - two "NEC PCI to USB Open Host Controller" and one "Standard Enhanced PCI to USB Host controller." With the card plugged in, I uninstalled those two drivers. I then removed the card. I copied the new drivers to c:\windows\system32\drivers and the .inf file to c:\windows\inf. I also copied the drivers & inf to a new directory called c:\windows\drivers\ousb2. I reinserted the card. Windows automatically installed the same drivers as before. I selected 'update driver' on the "NEC PCI to USB..." entry and didn't see any other options. I then selected 'have disk' and pointed to c:\windows\drivers\ousb2 and got a message "The specified location does not contain information about your hardware." I then selected 'update driver' on the "Standard Enhanced PCI to USB...," and manually selected "USB 2.0 Enhanced Host Controller" (OWC 4/15/2003 2.1.3.1). Windows then automatically found a USB root hub, and I manually selected "USB 2.0 Root Hub Device" (OWC 4/15/2003 2.1.3.1). Now there are two sections in the Device Manager titled "Universal Serial Bus controllers." I plugged in my external USB hard disk adapter, and "USB Mass Storage Device" was added to the first set. Here's how it looks (w/drivers from the properties): [Universal Serial Bus controllers] Intel(R) 82801DB/DBM USB 2.0 Enhanced Host Controller - 24CD (6/1/2002 5.1.2600.0) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C2 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C4 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C7 (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) USB Mass Storage Device USB Root Hub (7/1/2001 5.1.2600.5512) (5 more USB Root Hubs - same driver) [Universal Serial Bus controllers] USB 2.0 Enhanced Host Controller (OWC 4/15/2003 2.1.3.1) USB 2.0 Root Hub Device (OWC 4/15/2003 2.1.3.1) When I unplug the card the two "NEC PCI to USB..." entries in the first set disappear, and the whole second set disappears. (I unplugged the hard disk adapter first...) The hard disk adapter still doesn't work in that Cardbus card with the new drivers. I don't think the above looks right - a second set of USB controllers listed in the Device Manager, and the NEC entries still in the first set, and the the USB mass storage device still in the first set. Any help appreciated. (Windows XP PRO SP3 w/all current updates.)

    Read the article

  • Android emulator performance on linux

    - by Rado
    I installed the android SDK and eclipse plugin on my laptop, but I was surprised to find out that the emulator eats up 100% of one of my cpu cores. I have exactly the same setup on a desktop machine that does not have this issue. Both computers are running arch linux and both were updated yesterday. Granted, the desktop has better hardware than the laptop, but I was expecting to get closer to 50% cpu usage than 100% on the laptop. Both android virtual devices have the same specs: CPU: ARM Target: Android 2.3.3 - API Level 10 Skin: WVGA800 SD Card: 512M hw.lcd.density: 240 vm.heapSize: 24 hw.ramSize: 256 Laptop host has Intel Core 2 T7200 @ 2GHz cpu with 2Gb RAM. Desktop host has AMD Phenom II X4 940 @ 3GHz cpu with 8Gb RAM. The android emulator uses only 1 core and here are the CPU usage results: Laptop: Cpu0 : 22.8%us, 76.5%sy, 0.0%ni, 0.3%id, 0.0%wa, 0.0%hi, 0.3%si, 0.0%st Cpu1 : 11.2%us, 2.4%sy, 0.0%ni, 86.4%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 2055484k total, 1860304k used, 195180k free, 5276k buffers Swap: 2000088k total, 106872k used, 1893216k free, 350780k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 2026 xyz 20 0 396m 207m 7192 R 100 10.3 4:11.58 emulator-arm Desktop: Cpu0 : 0.7%us, 0.0%sy, 0.0%ni, 99.3%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Cpu1 : 1.3%us, 0.0%sy, 0.0%ni, 98.7%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Cpu2 : 5.0%us, 1.3%sy, 0.0%ni, 91.9%id, 1.7%wa, 0.0%hi, 0.0%si, 0.0%st Cpu3 : 0.3%us, 0.3%sy, 0.0%ni, 99.3%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 7666324k total, 6506808k used, 1159516k free, 1650960k buffers Swap: 8988348k total, 0k used, 8988348k free, 2867300k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 2811 xyz 20 0 392m 220m 6276 S 8 2.9 0:33.58 emulator-arm Is there any way I can improve the emulator performance on the laptop? [UPDATE] I ran the emulator with the same settings, on the same laptop under Win7 and after starting up, it didn't use 100% of a CPU core unlike under linux. Also, I tried running the emulator from a terminal in Linux and I get this message when I don't get it under the desktop Linux host: Could not configure '/dev/hpet' to have a 1024Hz timer. This is not a fatal error, but for better emulation accuracy type: 'echo 1024 /proc/sys/dev/hpet/max-user-freq' as root. I'm not really familiar with rtc or hpet, but it doesn't seem that max-user-freq setting does anything, I still get the same warning.

    Read the article

  • Can't manage iPod from linux anymore

    - by kemp
    I used to be able to see and manage my iPod with different softwares: Amarok, Rhythmbox, GTKPod. The device is a nano 1st generation 4gb. Currently it mounts regularly and can be accessed from the file system, but I get this in dmesg: [ 1547.617891] scsi 11:0:0:0: Direct-Access Apple iPod 1.62 PQ: 0 ANSI: 0 [ 1547.619103] sd 11:0:0:0: Attached scsi generic sg2 type 0 [ 1547.620478] sd 11:0:0:0: [sdb] Adjusting the sector count from its reported value: 7999488 [ 1547.620494] sd 11:0:0:0: [sdb] 7999487 512-byte hardware sectors: (4.09 GB/3.81 GiB) [ 1547.621718] sd 11:0:0:0: [sdb] Write Protect is off [ 1547.621726] sd 11:0:0:0: [sdb] Mode Sense: 68 00 00 08 [ 1547.621732] sd 11:0:0:0: [sdb] Assuming drive cache: write through [ 1547.623591] sd 11:0:0:0: [sdb] Adjusting the sector count from its reported value: 7999488 [ 1547.624993] sd 11:0:0:0: [sdb] Assuming drive cache: write through [ 1547.625003] sdb: sdb1 sdb2 [ 1547.629686] sd 11:0:0:0: [sdb] Attached SCSI removable disk [ 1548.084026] FAT: utf8 is not a recommended IO charset for FAT filesystems, filesystem will be case sensitive! [ 1548.369502] FAT: utf8 is not a recommended IO charset for FAT filesystems, filesystem will be case sensitive! [ 1548.504358] FAT: invalid media value (0x2f) [ 1548.504363] VFS: Can't find a valid FAT filesystem on dev sdb1. [ 1548.945173] FAT: utf8 is not a recommended IO charset for FAT filesystems, filesystem will be case sensitive! [ 1548.945179] FAT: invalid media value (0x2f) [ 1548.945182] VFS: Can't find a valid FAT filesystem on dev sdb1. [ 1610.092886] usb 2-6: USB disconnect, address 9 The only application that can access it (partially) is Rhythmbox. I say partially because I can transfer files to the iPod but can't remove or modify them. Also one transfer didn't finish and only 9 out of 16 songs were delivered to the device. All other softwares I tried (GTKPod, Amarok, Songbird) don't even detect it. What can I do to troubleshoot this? EDIT: # fdisk -l /dev/sdb Disk /dev/sdb: 4095 MB, 4095737344 bytes 241 heads, 62 sectors/track, 535 cylinders Units = cylinders of 14942 * 512 = 7650304 bytes Disk identifier: 0x20202020 Device Boot Start End Blocks Id System /dev/sdb1 1 11 80293+ 0 Empty Partition 1 has different physical/logical beginnings (non-Linux?): phys=(0, 1, 1) logical=(0, 1, 2) Partition 1 has different physical/logical endings: phys=(9, 254, 63) logical=(10, 181, 8) Partition 1 does not end on cylinder boundary. /dev/sdb2 11 536 3919415+ b W95 FAT32 Partition 2 has different physical/logical beginnings (non-Linux?): phys=(10, 0, 7) logical=(10, 181, 15) Partition 2 has different physical/logical endings: phys=(497, 240, 62) logical=(535, 88, 61) EDIT2: The "before" state is hard to tell, it was a lot of updates ago. Haven't been using my iPod for a while so I can't say when exactly it stopped working. I'm sure Amarok was still at version 1.X but can't remember when it was. My current system is debian testing fully updated. NOTE: just noticed that if I mount the device manually instead of letting nautilus automount it, I can see it again on GTKPod but still not on Banshee AND it's vanished from Rhythmbox...

    Read the article

  • Windows Server 2008 - one MAC Address, assign multiple external IP's to VirtualBoxes running as guests on host

    - by Sise
    Couldn't find any help @ google or here. The scenario: Windows Server 2008 Std x64 on i7-975, 12 GB RAM. The server is running in a data centre. One hardware NIC - RealTek PCIe GBE - one MAC Address. The data centre provides us 4 static external IP's. The first is assigned to the host by default of course. I have ordered all 4 IP's, the data centre can assign the available IP's to the physical MAC address of the given NIC only. This means one NIC, one MAC Address, 4 IP's. Everything works fine so far. Now, what I would like to have: Installed VirtualBox with 1-3 guests running, each gets it's own external IP assigned. Each of it should be an standalone Win Server 2008. It looks like the easiest way would be to put the guests into an virtual subnet and routing all data coming to the 2nd till 4th external IP through to this guests using there subnet IP's. I have been through the VirtualBox User Manuel regarding networking. What's not working: I can't use bridged networking without anything else, because the IP's are assigned to the one MAC address only. I can't use NAT networking because it does not allow access from outside or the host to the guest. I do not wanna use port forwarding. Host-only networking itself would not allow internet access, by sharing the default internet connection of the host, internet is granted from the guest to the outside but not from outside or the host to the guest. InternalNetworking is not really an option here. What I have tried is to create an additional MS Loopback adapter for a routed subnet, where the Vbox guests are in, now the idea was to NAT the internet connection to the loopback 'subnet'. But I can't ping the gateway from the guests. By using route command in the command shell or RRAS (static route, NAT) I didn't get there as well. Solutions like the following do work for the one way, but not for the way back: For your situation, it might be best to use the Host-Only adapter for ICS. Go to the preferences of VB itself and select network. There you can change the configuration for the interface. Set the IP address to 192.168.0.1, netmask 255.255.255.0. Disable the DHCP server if it isn't already and that's it. Now the Guest should get an IP from Windows itself and be able to get onto the internet, while you can also access the Host. Slowly I'm pretty stucked with this topic. There is a possibility I've just overlooked something or just didn't getting it by trying, especially using RRAS, but it's kinda hard to find useful howto's or something in the web. Thanks in advance! Best regards, Simon

    Read the article

  • Recommendations for distributed processing/distributed storage systems

    - by Eddie
    At my organization we have a processing and storage system spread across two dozen linux machines that handles over a petabyte of data. The system right now is very ad-hoc; processing automation and data management is handled by a collection of large perl programs on independent machines. I am looking at distributed processing and storage systems to make it easier to maintain, evenly distribute load and data with replication, and grow in disk space and compute power. The system needs to be able to handle millions of files, varying in size between 50 megabytes to 50 gigabytes. Once created, the files will not be appended to, only replaced completely if need be. The files need to be accessible via HTTP for customer download. Right now, processing is automated by perl scripts (that I have complete control over) which call a series of other programs (that I don't have control over because they are closed source) that essentially transforms one data set into another. No data mining happening here. Here is a quick list of things I am looking for: Reliability: These data must be accessible over HTTP about 99% of the time so I need something that does data replication across the cluster. Scalability: I want to be able to add more processing power and storage easily and rebalance the data on across the cluster. Distributed processing: Easy and automatic job scheduling and load balancing that fits with processing workflow I briefly described above. Data location awareness: Not strictly required but desirable. Since data and processing will be on the same set of nodes I would like the job scheduler to schedule jobs on or close to the node that the data is actually on to cut down on network traffic. Here is what I've looked at so far: Storage Management: GlusterFS: Looks really nice and easy to use but doesn't seem to have a way to figure out what node(s) a file actually resides on to supply as a hint to the job scheduler. GPFS: Seems like the gold standard of clustered filesystems. Meets most of my requirements except, like glusterfs, data location awareness. Ceph: Seems way to immature right now. Distributed processing: Sun Grid Engine: I have a lot of experience with this and it's relatively easy to use (once it is configured properly that is). But Oracle got its icy grip around it and it no longer seems very desirable. Both: Hadoop/HDFS: At first glance it looked like hadoop was perfect for my situation. Distributed storage and job scheduling and it was the only thing I found that would give me the data location awareness that I wanted. But I don't like the namename being a single point of failure. Also, I'm not really sure if the MapReduce paradigm fits the type of processing workflow that I have. It seems like you need to write all your software specifically for MapReduce instead of just using Hadoop as a generic job scheduler. OpenStack: I've done some reading on this but I'm having trouble deciding if it fits well with my problem or not. Does anyone have opinions or recommendations for technologies that would fit my problem well? Any suggestions or advise would be greatly appreciated. Thanks!

    Read the article

  • external hard drive is no longer recognized, gives buffer I/O errors

    - by BioGeek
    Hi all, The external hard drive which contains all my photos and where I backed-up all my important documents is no longer recognized. It is a three month old 500GB Iomage Prestige Desktop Hard Drive. When I plug it in, it is recognised as a USB device, because it shows up when I type lsusb, but dmesg gives this error message. [19712.013250] usb 2-2: new high speed USB device using ehci_hcd and address 21 [19712.145347] usb 2-2: configuration #1 chosen from 1 choice [19712.147214] scsi25 : SCSI emulation for USB Mass Storage devices [19712.147514] usb-storage: device found at 21 [19712.147519] usb-storage: waiting for device to settle before scanning [19717.148978] usb-storage: device scan complete [19717.149527] scsi 25:0:0:0: Direct-Access ST350082 0AS PQ: 0 ANSI: 2 CCS [19717.151020] sd 25:0:0:0: Attached scsi generic sg2 type 0 [19717.151685] sd 25:0:0:0: [sdb] 976773168 512-byte logical blocks: (500 GB/465 GiB) [19717.160402] sd 25:0:0:0: [sdb] Write Protect is off [19717.160412] sd 25:0:0:0: [sdb] Mode Sense: 34 00 00 00 [19717.160418] sd 25:0:0:0: [sdb] Assuming drive cache: write through [19717.165685] sd 25:0:0:0: [sdb] Assuming drive cache: write through [19717.165691] sdb: sdb1 [19719.171808] sd 25:0:0:0: [sdb] Assuming drive cache: write through [19719.171818] sd 25:0:0:0: [sdb] Attached SCSI disk [19737.430998] sd 25:0:0:0: [sdb] Unhandled sense code [19737.431007] sd 25:0:0:0: [sdb] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE [19737.431016] sd 25:0:0:0: [sdb] Sense Key : Medium Error [current] [19737.431027] sd 25:0:0:0: [sdb] Add. Sense: Unrecovered read error [19737.431038] end_request: I/O error, dev sdb, sector 6160463 [19737.431050] Buffer I/O error on device sdb1, logical block 6160400 [19737.431060] Buffer I/O error on device sdb1, logical block 6160401 [19737.431067] Buffer I/O error on device sdb1, logical block 6160402 [19737.431075] Buffer I/O error on device sdb1, logical block 6160403 [19737.431082] Buffer I/O error on device sdb1, logical block 6160404 [19737.431088] Buffer I/O error on device sdb1, logical block 6160405 [19737.431096] Buffer I/O error on device sdb1, logical block 6160406 [19737.431102] Buffer I/O error on device sdb1, logical block 6160407 [19737.431114] Buffer I/O error on device sdb1, logical block 6160408 [19737.431121] Buffer I/O error on device sdb1, logical block 6160409 [19737.712183] sd 6:0:0:0: [sdb] Unhandled sense code [19737.712191] sd 6:0:0:0: [sdb] Result: hostbyte=DID_ERROR driverbyte=DRIVER_SENSE [19737.712200] sd 6:0:0:0: [sdb] Sense Key : Hardware Error [current] [19737.712210] sd 6:0:0:0: [sdb] Add. Sense: No additional sense information [19737.712222] end_request: I/O error, dev sdb, sector 0 [19737.712232] Buffer I/O error on device sdb, logical block 0 Neither does the external drive show when I use fdisk: jeroen@phalacrocorax:~$ sudo fdisk -l [sudo] password for jeroen: Disk /dev/sda: 160.0 GB, 160041885696 bytes 255 heads, 63 sectors/track, 19457 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x000341ad Device Boot Start End Blocks Id System /dev/sda1 * 1 18714 150320173+ 83 Linux /dev/sda2 18715 19457 5968147+ 5 Extended /dev/sda5 18715 19457 5968116 82 Linux swap / Solaris` I popped the disk out of the casing put it on a SATA connect internally and then tried the file recovery programs testdisk/photorec and SpinRite, but both failed because they couldn't recognize the external harddisk. Do I have any other options?

    Read the article

  • my multi boot can't boot to XP 'resumeobject' is missing

    - by GwenKillerby
    In my multi boot set up, booting to vista and 7 goes fine, but when I try to boot to XP, i get an error Windows failed to start. A recent hardware or software change might be the cause. To fix the problem: 1. Insert your Windows installation disc and restart your computer. 2. Choose your language settings, and then click "Next." 3. Click "Repair your computer." If you do not have this disc, contact your system administrator or computer manufacturer for assistance. File: \NTLDR Status: 0xc000000e Info: The selected entry could not be loaded because the application is missing or corrupt. See below. Clearly the resumeobject seems to be missing in the XP entry ("Real Mode Boot sector"), only I don't know how to restore it. Vista is on **C:**, Win7 is on **F:** (as is the bootmgr ??? ) and WinXP is on **E:** What I've tried: [1] I've used about 5 windows discs, that is the Recovery Consoles from real XP install CD's and 3 virtual Recovery Consoles. All failed. The real CD's work ONE time, but won't let me finish, I only got as far as [b]fixboot E:[/b] Then they shut the laptop down, I kid you not. On a next startup, all 5 CD's ask me for some Admin password that I've never added! [2] I have VisualBCD and EasyBCD, but the most obvious things I tried there didn't solve the problem. So know I don't exactly know what to do with them. [3] I CAN boot into XP with the FIX NTLDR workaround of http://milescomer.com/tinyempire.com/notes/ntldrismissing.htm, but it doesn't fix it permanently QUESTION: How do I fix it permanently? bcdedit /enum output: Windows Boot Manager -------------------- identifier {bootmgr} device partition=F: path \bootmgr description Windows Boot Manager locale en-US default {current} displayorder {current} {812e27a9-27b7-11e4-8fb4-dfa8174ae8dc} {812e27ac-27b7-11e4-8fb4-dfa8174ae8dc} timeout 30 resume No Windows Boot Loader ------------------- identifier {current} device partition=C: path \Windows\system32\winload.exe description Vista locale nl-NL osdevice partition=C: systemroot \Windows resumeobject {73d8b5bc-2764-11e4-b181-806e6f6e6963} Windows Boot Loader ------------------- identifier {812e27a9-27b7-11e4-8fb4-dfa8174ae8dc} device partition=F: path \Windows\system32\winload.exe description Daisy Etta locale en-US osdevice partition=F: systemroot \Windows resumeobject {b8c234a4-27b0-11e4-b8b3-806e6f6e6963} Real-mode Boot Sector --------------------- identifier {812e27ac-27b7-11e4-8fb4-dfa8174ae8dc} device partition=E: path \NTLDR description XP Thank you.

    Read the article

  • Quantifying the effects of partition mis-alignment

    - by Matt
    I'm experiencing some significant performance issues on an NFS server. I've been reading up a bit on partition alignment, and I think I have my partitions mis-aligned. I can't find anything that tells me how to actually quantify the effects of mis-aligned partitions. Some of the general information I found suggests the performance penalty can be quite high (upwards of 60%) and others say it's negligible. What I want to do is determine if partition alignment is a factor in this server's performance problems or not; and if so, to what degree? So I'll put my info out here, and hopefully the community can confirm if my partitions are indeed mis-aligned, and if so, help me put a number to what the performance cost is. Server is a Dell R510 with dual E5620 CPUs and 8 GB RAM. There are eight 15k 2.5” 600 GB drives (Seagate ST3600057SS) configured in hardware RAID-6 with a single hot spare. RAID controller is a Dell PERC H700 w/512MB cache (Linux sees this as a LSI MegaSAS 9260). OS is CentOS 5.6, home directory partition is ext3, with options “rw,data=journal,usrquota”. I have the HW RAID configured to present two virtual disks to the OS: /dev/sda for the OS (boot, root and swap partitions), and /dev/sdb for a big NFS share: [root@lnxutil1 ~]# parted -s /dev/sda unit s print Model: DELL PERC H700 (scsi) Disk /dev/sda: 134217599s Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 1 63s 465884s 465822s primary ext2 boot 2 465885s 134207009s 133741125s primary lvm [root@lnxutil1 ~]# parted -s /dev/sdb unit s print Model: DELL PERC H700 (scsi) Disk /dev/sdb: 5720768639s Sector size (logical/physical): 512B/512B Partition Table: gpt Number Start End Size File system Name Flags 1 34s 5720768606s 5720768573s lvm Edit 1 Using the cfq IO scheduler (default for CentOS 5.6): # cat /sys/block/sd{a,b}/queue/scheduler noop anticipatory deadline [cfq] noop anticipatory deadline [cfq] Chunk size is the same as strip size, right? If so, then 64kB: # /opt/MegaCli -LDInfo -Lall -aALL -NoLog Adapter #0 Number of Virtual Disks: 2 Virtual Disk: 0 (target id: 0) Name:os RAID Level: Primary-6, Secondary-0, RAID Level Qualifier-3 Size:65535MB State: Optimal Stripe Size: 64kB Number Of Drives:7 Span Depth:1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default Number of Spans: 1 Span: 0 - Number of PDs: 7 ... physical disk info removed for brevity ... Virtual Disk: 1 (target id: 1) Name:share RAID Level: Primary-6, Secondary-0, RAID Level Qualifier-3 Size:2793344MB State: Optimal Stripe Size: 64kB Number Of Drives:7 Span Depth:1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default Number of Spans: 1 Span: 0 - Number of PDs: 7 If it's not obvious, virtual disk 0 corresponds to /dev/sda, for the OS; virtual disk 1 is /dev/sdb (the exported home directory tree).

    Read the article

  • Ubuntu 12.10 Clock is wrong

    - by mardavi
    I have an issue with Ubuntu Quantal, as it shows the wrong time. It is completely messy, the right time from time.is now is 09.43 and my clock shows 17.48. I am using ntp service and I already checked the timezone and it is correct. I also checked the hardware clock through sudo hwclock --showsudo dpkg-reconfigure tzdata and this is right too. I also tried sudo dpkg-reconfigure tzdata but with bad luck. What else can I try? As asked, here my /etc/ntp.conf # /etc/ntp.conf, configuration for ntpd; see ntp.conf(5) for help driftfile /var/lib/ntp/ntp.drift # Enable this if you want statistics to be logged. #statsdir /var/log/ntpstats/ statistics loopstats peerstats clockstats filegen loopstats file loopstats type day enable filegen peerstats file peerstats type day enable filegen clockstats file clockstats type day enable # Specify one or more NTP servers. # Use servers from the NTP Pool Project. Approved by Ubuntu Technical Board # on 2011-02-08 (LP: #104525). See http://www.pool.ntp.org/join.html for # more information. server 0.ubuntu.pool.ntp.org server 1.ubuntu.pool.ntp.org server 2.ubuntu.pool.ntp.org server 3.ubuntu.pool.ntp.org server time.nist.gov # Use Ubuntu's ntp server as a fallback. server ntp.ubuntu.com # Access control configuration; see /usr/share/doc/ntp-doc/html/accopt.html for # details. The web page <http://support.ntp.org/bin/view/Support/AccessRestrictions> # might also be helpful. # # Note that "restrict" applies to both servers and clients, so a configuration # that might be intended to block requests from certain clients could also end # up blocking replies from your own upstream servers. # By default, exchange time with everybody, but don't allow configuration. restrict -4 default kod notrap nomodify nopeer noquery restrict -6 default kod notrap nomodify nopeer noquery # Local users may interrogate the ntp server more closely. restrict 127.0.0.1 restrict ::1 # Clients from this (example!) subnet have unlimited access, but only if # cryptographically authenticated. #restrict 192.168.123.0 mask 255.255.255.0 notrust # If you want to provide time to your local subnet, change the next line. # (Again, the address is an example only.) #broadcast 192.168.123.255 # If you want to listen to time broadcasts on your local subnet, de-comment the # next lines. Please do this only if you trust everybody on the network! #disable auth #broadcastclient In addition, the ntp service was not running when I turned on my laptop today.

    Read the article

  • 2 Servers setup for redundency, backup

    - by minal
    I presently have 1 dedicated virtual server running my website/blog/mail, etc. This is on Hyper-V with 512MB RAM. Windows Web2008. With the VM, I have these running within it: SmarterMail – for emails MS DNS – I have my own nameservers on this server SQL Express IIS7 2 IP Address I have now leased 2 physical servers : P4 2.6Ghz 1GB RAM 80GB HDD. With these new servers, I get 2 IPs per server as well. These are running Windows 2008 Standard. With the VM the HDD was obviously on a RAID setup so I was not worried about hardware issues as it fell on the provider to manage. However, with the new servers the HDD is not RAID’d, hence my concern is that if it fails I need a backup position. What would be the most ideal setup to go for? I am thinking: Server 1: (Web/PrimaryDNS) DNS – NS1 SQL Express – OFF turn on when required, ie. Server2 is down SmarterMail – OFF turn on when required, ie. Server2 is down IIS 7 Server2:(SQL/Backup) DNS – NS2 SQL Web Edition SmarterMail IIS 7 How can I set it up so that if 1 goes down I can have everything on 2 instantly or by manual switching over. I am confused as other DNS servers will cache the web servers IP address for requests, and if that server goes down, the backup server will have a different IP. How do I make this work? I will be doing routine backups, in which case I will keep copies of backups on both servers. If I am copying the same stuff on both servers like a mirror then I am losing on using the true performance out of it. It's like 1 server is always on standby. Ideally I want SQL and web on 2 diff machines for best performance. If Server1 goes down, I should be able to switch to Server2 fairly easily. I don't have a problem with manual intervention to start the sql/mail services, etc. In terms of scalabilty, the VM has coped pretty well to date. Moving forward the SQL and IIS workload is going to double pretty quickly. Some ideas would be great.

    Read the article

  • Router reconfigures PC's and they can no longer access the internet via hardwired connection to DSL Modem

    - by zchads
    Router reconfigures PC's and they can no longer access the internet via hardwired connection to DSL Modem. Hardware Information: Buffalo Wireless Router/access point, Model: WZR-HP-G300NH-AP DSL Modem: Generic (actually not sure of manufacture). Service Provider: TOT (Thailand) Laptop-1: Windows XP and Belkin PCMIA Network Card Laptop-2: Windows XP unknown network card & Wifi Laptop-3: Windows 7 unknown network card & Wifi Outline of Problem/actions taken: After a recent power failure the router and laptop-1 connected to router were no longer able to access the internet. Actions taken to try and recover internet access: Using Laptop-1 tried to configure Router with PPPoe settings using software from Router Manufacture. During the installation process a Timeout error was experienced, unable to connect to WAN. Used Internet Explorer to communicate directly with Router using IP address. Changed settings to use PPPoe settings given by ISP. Router was not able to communicate with Internet. Repeated steps 1-4 again with no success. Reset Router and DSL modem. Repeated steps 1-4 again still no success. Tried connecting Laptop-1 directly to DSL to gain access to internet to research problem. No Network connection with DSL could be established…connection would be established for a second and then be lost and didn’t appear long enough to actually connect to DSL. Replugged LAN back into Router and connection was regained with laptop-1. Replugged Laptop-1 directly into DSL and again unable to establish network connection. Uninstalled network card and all of its drivers on Laptop-1. Reinstalled network card and drivers and tried connecting directly to DSL. Still unable to make network connection. Plugged DSL into Laptop-3 and Internet connection was established. Being Laptop-3 does not have a CD-Rom, Laptop-2 was tried to connect to the router. With Laptop-2 steps 1-7 ended up being repeated without success. Tried plugging Laptop-2 directly into DSL and again no network connection could be established. Using Laptop-3 with a direct connection to DSL downloaded latest Router FW. Installed router FW using Laptop-1. Tired the installation process again without success. Being desperate reinstalled OS on Laptop-1 still not success. Tried using “ipconfig” with router to see what was going on without success. With laptop-1 connected to DSL went through the “ipconfig /…” inputs to see if anything made a difference. Being the network card was not able to make a connection this provide very little information “media disconnected”. So now I have a router and two laptops which are unable to connect to the internet and sure could use some advice/help.

    Read the article

  • Lenovo Ideapad Y480 can't reinstall windows?

    - by elegantonyx
    Alright, so here's the deal... For a while, I wanted to mess with Linux. I don't know why, but I wanted to. So, what I did was use WUBI and install Ubuntu. Because of some unknown reason (Intel Rapid Start? Half the drivers being on a Lenovo-installed SSD [separate from the main hard drive]?) it wouldn't dual boot. So, I decided to use Linux Mint instead, and install it in a partition. Since Windows 7 Home Premium won't make partitions any more if you have a certain number already, I just shrank my system drive and left empty space for the installer to claim. When I installed Mint, it worked, but left my Windows 7 installation unable to boot and eventually it corrupted. I tried to use a system repair disc I burned earlier but it didn't find the Windows installation, so I assume the partition corrupted. I used this link:http://www.pcworld.com/article/248995/how_to_install_windows_7_without_the_disc.html to try and reinstall Windows. What happened was that originally it said that the partition I was trying to reinstall from had been locked down by the OEM (Lenovo). So, I went into GParted, wiped EVERYTHING, and selected 'Construct new Boot record' or whatever that function is, and now the error is: "Setup was unable to create a new system partition or locate an existing system partition. See the setup log files for more information." Does anyone know how to see the log files? Can anyone help? This system is a month old but the warranty only covers hardware failures, and I would need to pay around USD$60 for them to fix it. Please help. Any ideas? this is my main machine... Extra information: I have at my disposal: System Repair Disc (Burned myself) Windows 7 Home Premium 64 bit SP1 installation disk (burned from the pcworld links) Gparted Live CD Linux Mint 13 live cd A system backup (from the morning before this catastrophe) made using the Windows Backup and Restore. I put it on an external drive...that should be safe for now.

    Read the article

  • My server freezes within a few hours of logging out. Staying logged in keeps the server running

    - by HappyEngineer
    I have an Ubuntu Godaddy server I use to host mail and webapps. It started having problems a couple months ago. It would lock up and stop responding to anything. I couldn't ssh into it, so I'd have godaddy power cycle the server. I have never seen anything that looked suspicious in the var logs (although I'm no expert at reading them). An fsck turned up no problems. Godaddy replaced the ram, but found no hardware problems. I started logging the output from "top" to a log file and found that even that stops running when the server freezes. Now, here is the crazy part: It got so bad that it would actually go down every few hours, but then it stopped going down. I eventually realized I had left an ssh terminal logged into the machine running top. This seemed unlikely to be a reason, but after the server was up with no problems for a full week (remember, it had been going down after just a few hours), I disconnected from the ssh session. Lo and behold, within a few hours the server froze again! I had them power cycle again and then left another ssh session open with top. It has been going without problems for 8 days now. I told others about this and they hardly believe me. I simply can't imagine what is going on. I don't know what else to try other than to just get a new server and reinstall everything. Does anyone have any ideas about what I can look for to determine what the cause is? Is it possible there's some sort of exploit on the server which only runs if everyone is logged out of the system? EDIT: The power management gone haywire sounds plausible, so I've modified the /boot/grub/menu.lst to boot with acpi=off and apm=off. It appears to have prevented kacpid and kacpid_notify from being in the process list, so I assume I did that right. I've disconnected all my sessions from the server. I'll check later tonight to see if it's still up. If it goes down then I'll try the pinging process idea. EDIT: It went down again. It lasted about a day. I've had them reboot, so now I'll try running "nohup ping -i 5 google.com &" and then disconnect. If it goes down again I'll come back. Hopefully someone will have some more ideas.

    Read the article

  • High Jitter in NTP and poll value never goes above 128

    - by Aseem
    I have a lot of servers syncing to the same NTP servers (4). Not every server is in the same LAN. Some are 3 hops away from the NTP servers and some are 6 hops away. On couple of servers I see that the poll value never touches the 1024 mark and the jitter value is in double digits. Could it be due to the system hardware? These are windows servers (physical) and require as accurate time as possible. Please advice what I should do. Some of the stats that I collected manually from the bad box (which is 6 hops away from the ntp servers) C:\Program Files (x86)\NTP>ntpq -p -n remote refid st t when poll reach delay offset jitter ============================================================================== +*.*.*.25 *.*.*.233 2 u 12 128 377 1.210 -12.579 14.913 +*.*.*.26 *.*.*.233 2 u 96 128 377 1.067 -2.235 9.885 **.*.*.27 *.*.*.233 2 u 24 128 377 1.038 -7.569 11.178 +*.*.*.28 *.*.*.233 2 u 49 128 377 1.288 -11.058 14.544 remote refid st t when poll reach delay offset jitter ============================================================================== +*.*.*.25 *.*.*.233 2 u 124 128 377 0.614 -6.212 5.329 +*.*.*.26 *.*.*.233 2 u 93 128 377 0.910 -9.431 3.111 +*.*.*.27 *.*.*.233 2 u 1 128 377 0.824 -7.428 3.129 **.*.*.28 *.*.*.233 2 u 84 128 377 1.503 -8.230 3.511 remote refid st t when poll reach delay offset jitter ============================================================================== **.*.*.25 *.*.*.233 2 u 117 128 377 1.235 -4.084 11.405 +*.*.*.26 *.*.*.233 2 u 96 128 377 1.335 -11.813 13.130 +*.*.*.27 *.*.*.233 2 u 130 128 377 1.549 -14.036 16.381 -*.*.*.28 *.*.*.233 2 u 79 128 377 1.258 13.395 22.203 remote refid st t when poll reach delay offset jitter ============================================================================== **.*.*.25 *.*.*.233 2 u 88 128 377 1.235 -4.084 14.068 +*.*.*.26 *.*.*.233 2 u 63 128 377 1.335 -11.813 17.086 +*.*.*.27 *.*.*.233 2 u 103 128 377 1.549 -14.036 20.691 -*.*.*.28 *.*.*.233 2 u 47 128 377 1.258 13.395 20.231 remote refid st t when poll reach delay offset jitter ============================================================================== +*.*.*.25 *.*.*.233 2 u 47 64 377 0.652 -15.805 14.077 **.*.*.26 *.*.*.233 2 u 11 64 377 1.013 -14.423 11.375 -*.*.*.27 *.*.*.233 2 u 63 64 377 0.765 -2.030 7.680 +*.*.*.28 *.*.*.233 2 u 4 64 377 1.191 -17.980 14.393 remote refid st t when poll reach delay offset jitter ============================================================================== -*.*.*.25 *.*.*.233 2 u 3 128 377 1.576 18.665 21.999 +*.*.*.26 *.*.*.233 2 u 73 128 377 0.637 -5.012 14.405 **.*.*.27 *.*.*.233 2 u 127 128 377 0.272 -8.237 14.438 +*.*.*.28 *.*.*.233 2 u 123 128 377 1.190 -14.383 18.875 C:\Program Files (x86)\NTP>ntpdc -c loopinfo offset: -0.016430 s frequency: 7.106 ppm poll adjust: 18 watchdog timer: 133 s offset: -0.016430 s frequency: 7.106 ppm poll adjust: 18 watchdog timer: 341 s offset: -0.000149 s frequency: 6.645 ppm poll adjust: 0 watchdog timer: 383 s offset: 0.015735 s frequency: 6.725 ppm poll adjust: 7 watchdog timer: 577 s offset: -0.010331 s frequency: 6.748 ppm poll adjust: 21 watchdog timer: 567 s offset: -0.009427 s frequency: 6.687 ppm poll adjust: 28 watchdog timer: 301 s offset: -0.007361 s frequency: 6.612 ppm poll adjust: 30 watchdog timer: 155 s offset: -0.008106 s frequency: 4.358 ppm poll adjust: 30 watchdog timer: 291 s NTP.conf # NTP configuration file # Use drift file driftfile "C:\Program Files (x86)\NTP\ntp.drift" # Logs statistics loopstats peerstats clockstats statsdir "C:\Program Files (x86)\NTP\logs\" # directory for statistics files filegen peerstats file peerstats type day enable filegen loopstats file loopstats type day enable filegen clockstats file clockstats type day enable logfile "C:\Program Files (x86)\NTP\logs\syslog.txt" # Use specific NTP servers server *.*.*.25 minpoll 4 maxpoll 7 iburst server *.*.*.26 minpoll 4 maxpoll 7 iburst server *.*.*.27 minpoll 4 maxpoll 7 iburst server *.*.*.28 minpoll 4 maxpoll 7 iburst

    Read the article

  • Transferring a Windows 8 license and proper un- and reinstallation

    - by Kiwi
    Long story short I have two computers: a laptop and a desktop computer. Both have Windows 7 on them. I buy the Windows 8 Pro upgrade. To see if it screws up anything, I install it on my laptop as a guinea pig. I intend to use Windows 8 for my main computer, my desktop, but I want to test it on the laptop, so I know I don’t risk losing access to my desktop and the data on it. I never use my laptop, and only used it, because it already has a Windows 7 installation on it. The problem At some point, I must have entered the license key on my laptop, because when I go to the activation screen on my desktop, I get this: Uh-oh. I can’t use the key on my desktop. Now how the hell do I transfer the key from my laptop to my desktop computer? Answers and suggestions so far Let’s just say that I tried everything possible to get some answers on this matter. The best response I got from Microsoft is this: To install Windows 8 on your desktop, do the following: Uninstall Windows 8 on your laptop Afterwards, install Windows 8 on your desktop If it won’t activate, call product activation at (...) I am not a fan of that last point. The error message does allude to such a solution, however: If you’ve reinstalled Windows or made changes to your hardware recently, you may be able to use your current key. The question My main question is this: has anyone been in a similar situation, and if so, what did you do to resolve this? Failing that, what is the proper way to uninstall the Windows 8 installation on my laptop, and reinstall the Windows 8 installation on my desktop? Ad 1 I have already tried using the “reset” feature on my laptop, but that only resulted in a new Windows 8 installation that was already activated. But which is the right way to uninstall the installation in a way that allows me to use the license key on the desktop computer? Ad 2 Which is the proper way to reinstall the Windows 8 installation on my desktop computer? Why do I even have to reinstall it in the first place? I won’t get around to do this, until my USB key with 3.0 support arrives in the mail, but it is going to be a while, until I find a assuaging response to the best way to go about this anyway.

    Read the article

  • Graphics driver for ubuntu on dell latitude XT

    - by marc.riera
    we have a laptop (dell latitude xt) on our company, and we would like to install ubuntu on it. windows 7 works fine out of the box, so the hardware is fine. since this laptop has a touchscreen we just installed ubuntu 10.10 netbook edition 32x. But, we do not manage to enable the touchscreen, neither the vga graphic drivers. this is the output from lspci, if somebody cares. 00:00.0 Host bridge: ATI Technologies Inc Radeon Xpress 7930 Host Bridge 00:01.0 PCI bridge: ATI Technologies Inc RS7932 PCI Bridge 00:04.0 PCI bridge: ATI Technologies Inc Device 7934 00:06.0 PCI bridge: ATI Technologies Inc RS7936 PCI Bridge 00:07.0 PCI bridge: ATI Technologies Inc Device 7937 00:13.0 USB Controller: ATI Technologies Inc SB600 USB (OHCI0) 00:13.1 USB Controller: ATI Technologies Inc SB600 USB (OHCI1) 00:13.2 USB Controller: ATI Technologies Inc SB600 USB (OHCI2) 00:13.3 USB Controller: ATI Technologies Inc SB600 USB (OHCI3) 00:13.4 USB Controller: ATI Technologies Inc SB600 USB (OHCI4) 00:13.5 USB Controller: ATI Technologies Inc SB600 USB Controller (EHCI) 00:14.0 SMBus: ATI Technologies Inc SBx00 SMBus Controller (rev 14) 00:14.1 IDE interface: ATI Technologies Inc SB600 IDE 00:14.2 Audio device: ATI Technologies Inc SBx00 Azalia (Intel HDA) 00:14.3 ISA bridge: ATI Technologies Inc SB600 PCI to LPC Bridge 00:14.4 PCI bridge: ATI Technologies Inc SBx00 PCI to PCI Bridge 01:05.0 VGA compatible controller: ATI Technologies Inc Radeon Xpress 1250 03:01.0 CardBus bridge: Texas Instruments PCIxx12 Cardbus Controller 03:01.1 FireWire (IEEE 1394): Texas Instruments PCIxx12 OHCI Compliant IEEE 1394 Host Controller 03:01.3 SD Host controller: Texas Instruments PCIxx12 SDA Standard Compliant SD Host Controller 09:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5756ME Gigabit Ethernet PCI Express 0b:00.0 Network controller: Broadcom Corporation BCM4321 802.11a/b/g/n (rev 03) I've tryied to install ati drivers 9.3 , which I downloaded and installed, unpacked and installed, builded and installed, but nothing worked. Looks like the latests version is just accepted to work on jaunty 9.04, so they are kind of old. what else I can do? thanks. Marc Information added: lsusb and lspci -n |grep 01:05.0 sysop@wl083517:~$ lspci -n |grep 01:05.0 01:05.0 0300: 1002:7942 sysop@wl083517:~$ lsusb Bus 006 Device 002: ID 413c:8138 Dell Computer Corp. Wireless 5520 Voda I Mobile Broadband (3G HSDPA) Minicard EAP-SIM Port Bus 006 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 005 Device 002: ID 413c:8140 Dell Computer Corp. Wireless 360 Bluetooth Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 002: ID 0483:2016 SGS Thomson Microelectronics Fingerprint Reader Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 002: ID 1b96:0001 N-Trig Duosense Transparent Electromagnetic Digitizer Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 002 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 001 Device 002: ID 03f0:1807 Hewlett-Packard Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub sysop@wl083517:~$

    Read the article

  • Certain clients (IP range) can not ping server

    - by Logman
    I just virtualized a Windows 2003 Server SP2 x32. The server contained our help desk server (Spiceworks) and our anti virus management server (ESET RAC). The host computer actually contained the virtualized server originally; I created the vhd and then I wiped this system clean and installed Windows 2008 R2 x64 Datacenter and added the virtualized 2003 onto the Hyper-V 2008 R2 Server. I got the server running fine except for... certain ip ranges. Local clients can get updates from the AV server from my 192.168.180.xxx & 192.168.181.xxx BUT NOT from any 192.168.182.xxx, 192.168.183.xxx, 192.168.184.xxx etc... I can not ping the server from any clients except for the 180. & 181. ranges. Now I created 2 other virtualized servers (win2008 & a win7 pro) and they exist on the same virtual host as the 2003 server. And at first I could not ping those until I went to the "\Network and Sharing Center\Advanced sharing settings" and Turned On File and Print Sharing. Then I could ping and access those virtualized guests. Win2003 server isn't quite the same. But I am sure I have it on. But now when I ping from a client on one of those ranges that would not work I get this: As you can see the ping leaves our network. We have 2 ad/dns servers (one 180. & the other in the 181. range). Is it DNS? Both AD/DNS servers are Windows 2003. And we plan on upgrading both to 2008 R2 within a month or two but I need to fix this issue pronto (esp the AV end). btw, I did rename that 2003 Server (Spiceworks/AV) hostname. And I tried a CNAME. But I do not think that is the problem. EDIT: OR because this server existed on this hardware/computer before becoming virtualized?

    Read the article

  • SAS Expanders vs Direct Attached (SAS)?

    - by jemmille
    I have a storage unit with 2 backplanes. One backplane holds 24 disks, one backplane holds 12 disks. Each backplane is independently connected to a SFF-8087 port (4 channel/12Gbit) to the raid card. Here is where my question really comes in. Can or how easily can a backplane be overloaded? All the disks in the machine are WD RE4 WD1003FBYX (black) drives that have average writes at 115MB/sec and average read of 125 MB/sec I know things would vary based on the raid or filesystem we put on top of that but it seems to be that a 24 disk backplane with only one SFF-8087 connector should be able to overload the bus to a point that might actually slow it down? Based on my math, if I had a RAID0 across all 24 disks and asked for a large file, I should, in theory should get 24*115 MB/sec wich translates to 22.08 GBit/sec of total throughput. Either I'm confused or this backplane is horribly designed, at least in a perfomance environment. I'm looking at switching to a model where each drive has it's own channel from the backplane (and new HBA's or raid card). EDIT: more details We have used both pure linux (centos), open solaris, software raid, hardware raid, EXT3/4, ZFS. Here are some examples using bonnie++ 4 Disk RAID-0, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 194MB/s 19% 92MB/s 11% 200MB/s 8% 310/sec 194MB/s 19% 93MB/s 11% 201MB/s 8% 312/sec --------- ---- --------- ---- --------- ---- --------- 389MB/s 19% 186MB/s 11% 402MB/s 8% 311/sec 8 Disk RAID-0, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 324MB/s 32% 164MB/s 19% 346MB/s 13% 466/sec 324MB/s 32% 164MB/s 19% 348MB/s 14% 465/sec --------- ---- --------- ---- --------- ---- --------- 648MB/s 32% 328MB/s 19% 694MB/s 13% 465/sec 12 Disk RAID-0, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 377MB/s 38% 191MB/s 22% 429MB/s 17% 537/sec 376MB/s 38% 191MB/s 22% 427MB/s 17% 546/sec --------- ---- --------- ---- --------- ---- --------- 753MB/s 38% 382MB/s 22% 857MB/s 17% 541/sec Now 16 Disk RAID-0, it's gets interesting WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 359MB/s 34% 186MB/s 22% 407MB/s 18% 1397/sec 358MB/s 33% 186MB/s 22% 407MB/s 18% 1340/sec --------- ---- --------- ---- --------- ---- --------- 717MB/s 33% 373MB/s 22% 814MB/s 18% 1368/sec 20 Disk RAID-0, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 371MB/s 37% 188MB/s 22% 450MB/s 19% 775/sec 370MB/s 37% 188MB/s 22% 447MB/s 19% 797/sec --------- ---- --------- ---- --------- ---- --------- 741MB/s 37% 376MB/s 22% 898MB/s 19% 786/sec 24 Disk RAID-1, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 347MB/s 34% 193MB/s 22% 447MB/s 19% 907/sec 347MB/s 34% 192MB/s 23% 446MB/s 19% 933/sec --------- ---- --------- ---- --------- ---- --------- 694MB/s 34% 386MB/s 22% 894MB/s 19% 920/sec 28 Disk RAID-0, ZFS 32 Disk RAID-0, ZFS 36 Disk RAID-0, ZFS More details: Here is the exact unit: http://www.supermicro.com/products/chassis/4U/847/SC847E1-R1400U.cfm

    Read the article

  • Linux RAID-0 performance doesn't scale up over 1 GB/s

    - by wazoox
    I have trouble getting the max throughput out of my setup. The hardware is as follow : dual Quad-Core AMD Opteron(tm) Processor 2376 16 GB DDR2 ECC RAM dual Adaptec 52245 RAID controllers 48 1 TB SATA drives set up as 2 RAID-6 arrays (256KB stripe) + spares. Software : Plain vanilla 2.6.32.25 kernel, compiled for AMD-64, optimized for NUMA; Debian Lenny userland. benchmarks run : disktest, bonnie++, dd, etc. All give the same results. No discrepancy here. io scheduler used : noop. Yeah, no trick here. Up until now I basically assumed that striping (RAID 0) several physical devices should augment performance roughly linearly. However this is not the case here : each RAID array achieves about 780 MB/s write, sustained, and 1 GB/s read, sustained. writing to both RAID arrays simultaneously with two different processes gives 750 + 750 MB/s, and reading from both gives 1 + 1 GB/s. however when I stripe both arrays together, using either mdadm or lvm, the performance is about 850 MB/s writing and 1.4 GB/s reading. at least 30% less than expected! running two parallel writer or reader processes against the striped arrays doesn't enhance the figures, in fact it degrades performance even further. So what's happening here? Basically I ruled out bus or memory contention, because when I run dd on both drives simultaneously, aggregate write speed actually reach 1.5 GB/s and reading speed tops 2 GB/s. So it's not the PCIe bus. I suppose it's not the RAM. It's not the filesystem, because I get exactly the same numbers benchmarking against the raw device or using XFS. And I also get exactly the same performance using either LVM striping and md striping. What's wrong? What's preventing a process from going up to the max possible throughput? Is Linux striping defective? What other tests could I run?

    Read the article