Search Results

Search found 3906 results on 157 pages for 'guid generation'.

Page 41/157 | < Previous Page | 37 38 39 40 41 42 43 44 45 46 47 48  | Next Page >

  • HP Envy 15 3040nr sound issues

    - by Lenny
    I have successfully set up my Envy 15" for Ubuntu 12.04 except for the sound, anyone have any ideas about how to get it working? I had to blacklist snd-usb-audio to my alsa to stop pulseaudio from freezing on login and logout, but now no sound plays. Could anyone provide me with some guidance? lspci info 00:00.0 Host bridge: Intel Corporation 2nd Generation Core Processor Family DRAM Controller (rev 09) 00:01.0 PCI bridge: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port (rev 09) 00:01.1 PCI bridge: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port (rev 09) 00:01.2 PCI bridge: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port (rev 09) 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09) 00:16.0 Communication controller: Intel Corporation 6 Series/C200 Series Chipset Family MEI Controller #1 (rev 04) 00:1a.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 (rev 05) 00:1b.0 Audio device: Intel Corporation 6 Series/C200 Series Chipset Family High Definition Audio Controller (rev 05) 00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b5) 00:1c.2 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 3 (rev b5) 00:1c.4 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 5 (rev b5) 00:1c.7 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 8 (rev b5) 00:1d.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 (rev 05) 00:1f.0 ISA bridge: Intel Corporation HM65 Express Chipset Family LPC Controller (rev 05) 00:1f.2 SATA controller: Intel Corporation 6 Series/C200 Series Chipset Family 6 port SATA AHCI Controller (rev 05) 00:1f.3 SMBus: Intel Corporation 6 Series/C200 Series Chipset Family SMBus Controller (rev 05) 01:00.0 VGA compatible controller: Advanced Micro Devices [AMD] nee ATI Whistler [AMD Radeon HD 6600M Series] 09:00.0 Network controller: Intel Corporation Centrino Advanced-N 6230 (rev 34) 0a:00.0 Unassigned class [ff00]: Realtek Semiconductor Co., Ltd. RTS5116 PCI Express Card Reader (rev 01) 10:00.0 Ethernet controller: Atheros Communications Inc. AR8151 v2.0 Gigabit Ethernet (rev c0) 11:00.0 USB controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 04)

    Read the article

  • Touchpad right click doesn't work on HP Envy 14 beats

    - by jdrageme01
    I have Ubuntu 12.04 lts 64 bits on my HP envy 14 beats. When I try to click with the right click button it doesn't work. Only works click in the touchpad directly and with usb mouse. 00:00.0 Host bridge [0600]: Intel Corporation 2nd Generation Core Processor Family DRAM Controller [8086:0104] (rev 09) 00:01.0 PCI bridge [0604]: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port [8086:0101] (rev 09) 00:01.1 PCI bridge [0604]: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port [8086:0105] (rev 09) 00:01.2 PCI bridge [0604]: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port [8086:0109] (rev 09) 00:02.0 VGA compatible controller [0300]: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller [8086:0116] (rev 09) 00:16.0 Communication controller [0780]: Intel Corporation 6 Series/C200 Series Chipset Family MEI Controller #1 [8086:1c3a] (rev 04) 00:1a.0 USB controller [0c03]: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 [8086:1c2d] (rev 05) 00:1b.0 Audio device [0403]: Intel Corporation 6 Series/C200 Series Chipset Family High Definition Audio Controller [8086:1c20] (rev 05) 00:1c.0 PCI bridge [0604]: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 [8086:1c10] (rev b5) 00:1c.4 PCI bridge [0604]: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 5 [8086:1c18] (rev b5) 00:1c.7 PCI bridge [0604]: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 8 [8086:1c1e] (rev b5) 00:1d.0 USB controller [0c03]: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 [8086:1c26] (rev 05) 00:1f.0 ISA bridge [0601]: Intel Corporation HM65 Express Chipset Family LPC Controller [8086:1c49] (rev 05) 00:1f.2 SATA controller [0106]: Intel Corporation 6 Series/C200 Series Chipset Family 6 port SATA AHCI Controller [8086:1c03] (rev 05) 00:1f.3 SMBus [0c05]: Intel Corporation 6 Series/C200 Series Chipset Family SMBus Controller [8086:1c22] (rev 05) 01:00.0 VGA compatible controller [0300]: Advanced Micro Devices [AMD] nee ATI Whistler [AMD Radeon HD 6600M Series] [1002:6741] 09:00.0 Network controller [0280]: Intel Corporation Centrino Ultimate-N 6300 [8086:4238] (rev 3e) 0a:00.0 Ethernet controller [0200]: Atheros Communications Inc. AR8151 v2.0 Gigabit Ethernet [1969:1083] (rev c0) 0b:00.0 USB controller [0c03]: NEC Corporation uPD720200 USB 3.0 Host Controller [1033:0194] (rev 04)

    Read the article

  • Does more heat generation mean more wear and tear?

    - by Suhail Gupta
    I read that hardware generally used on PC is not optimized for running Linux. That is the reason the machine emits large amount of heat and doesn't give the battery back up , that we will get while working on windows. ~REF Does it also mean more wear and tear of the hardware (when using linux as compared when using windows ) ? Note : I have personally experienced large heat emission while working with Fedora 16 and Ubuntu 11.xx on my laptop.

    Read the article

  • Initialize array in amortized constant time -- what is this trick called?

    - by user946850
    There is this data structure that trades performance of array access against the need to iterate over it when clearing it. You keep a generation counter with each entry, and also a global generation counter. The "clear" operation increases the generation counter. On each access, you compare local vs. global generation counters; if they differ, the value is treated as "clean". This has come up in this answer on Stack Overflow recently, but I don't remember if this trick has an official name. Does it? One use case is Dijkstra's algorithm if only a tiny subset of the nodes has to be relaxed, and if this has to be done repeatedly.

    Read the article

  • Initialize array in O(1) -- how is this trick called?

    - by user946850
    There is this pattern that trades performance of array access against the need to iterate it when clearing it. You keep a generation counter with each entry, and also a global generation counter. The "clear" operation increases the generation counter. On each access, you compare local vs. global generation counters; if they differ, the array has been reset. This has come up in StackOverflow recently, but I don't remember if this trick has an official name. Does it? One use case is Dijkstra's algorithm if only a tiny subset of the nodes has to be relaxed, and if this has to be done repeatedly.

    Read the article

  • Updating the managed debugging API for .NET v4

    - by Brian Donahue
    In any successful investigation, the right tools play a big part in collecting evidence about the state of the "crime scene" as it was before the detectives arrived. Unfortunately for the Crash Scene Investigator, we don't have the budget to fly out to the customer's site, chalk the outline, and eat their doughnuts. We have to rely on the end-user to collect the evidence for us, which means giving them the fingerprint dust and the evidence baggies and leaving them to it. With that in mind, the Red Gate support team have been writing tools that can collect vital clues with a minimum of fuss. Years ago we would have asked for a memory dump, where we used to get the customer to run CDB.exe and produce dumps that we could analyze in-house, but those dumps were pretty unwieldy (500MB files) and the debugger often didn't dump exactly where we wanted, or made five or more dumps. What we wanted was just the minimum state information from the program at the time of failure, so we produced a managed debugger that captured every first and second-chance exception and logged the stack and a minimal amount of variables from the memory of the application, which could all be exported as XML. This caused less inconvenience to the end-user because it is much easier to send a 65KB XML file in an email than a 500MB file containing all of the application's memory. We don't need to have the entire victim shipped out to us when we just want to know what was under the fingernails. The thing that made creating a managed debugging tool possible was the MDbg Engine example written by Microsoft as part of the Debugging Tools for Windows distribution. Since the ICorDebug interface is a bit difficult to understand, they had kindly created some wrappers that provided an event-driven debugging model that was perfect for our needs, but .NET 4 applications under debugging started complaining that "The debugger's protocol is incompatible with the debuggee". The introduction of .NET Framework v4 had changed the managed debugging API significantly, however, without an update for the MDbg Engine code! After a few hours of research, I had finally worked out that most of the version 4 ICorDebug interface still works much the same way in "legacy" v2 mode and there was a relatively easy fix for the problem in that you can still get a reference to legacy ICorDebug by changing the way the interface is created. In .NET v2, the interface was acquired using the CreateDebuggingInterfaceFromVersion method in mscoree.dll. In v4, you must first create IClrMetaHost, enumerate the runtimes, get an ICLRRuntimeInfo interface to the .NET 4 runtime from that, and use the GetInterface method in mscoree.dll to return a "legacy" ICorDebug interface. The rest of the MDbg Engine will continue working the old way. Here is how I had changed the MDbg Engine code to support .NET v4: private void InitFromVersion(string debuggerVersion){if( debuggerVersion.StartsWith("v1") ){throw new ArgumentException( "Can't debug a version 1 CLR process (\"" + debuggerVersion + "\"). Run application in a version 2 CLR, or use a version 1 debugger instead." );} ICorDebug rawDebuggingAPI=null;if (debuggerVersion.StartsWith("v4")){Guid CLSID_MetaHost = new Guid("9280188D-0E8E-4867-B30C-7FA83884E8DE"); Guid IID_MetaHost = new Guid("D332DB9E-B9B3-4125-8207-A14884F53216"); ICLRMetaHost metahost = (ICLRMetaHost)NativeMethods.ClrCreateInterface(CLSID_MetaHost, IID_MetaHost); IEnumUnknown runtimes = metahost.EnumerateInstalledRuntimes(); ICLRRuntimeInfo runtime = GetRuntime(runtimes, debuggerVersion); //Defined in metahost.hGuid CLSID_CLRDebuggingLegacy = new Guid(0xDF8395B5, 0xA4BA, 0x450b, 0xA7, 0x7C, 0xA9, 0xA4, 0x77, 0x62, 0xC5, 0x20);Guid IID_ICorDebug = new Guid("3D6F5F61-7538-11D3-8D5B-00104B35E7EF"); Object res;runtime.GetInterface(ref CLSID_CLRDebuggingLegacy, ref IID_ICorDebug, out res); rawDebuggingAPI = (ICorDebug)res; }elserawDebuggingAPI = NativeMethods.CreateDebuggingInterfaceFromVersion((int)CorDebuggerVersion.Whidbey,debuggerVersion);if (rawDebuggingAPI != null)InitFromICorDebug(rawDebuggingAPI);elsethrow new ArgumentException("Support for debugging version " + debuggerVersion + " is not yet implemented");} The changes above will ensure that the debugger can support .NET Framework v2 and v4 applications with the same codebase, but we do compile two different applications: one targeting v2 and the other v4. As a footnote I need to add that some missing native methods and wrappers, along with the EnumerateRuntimes method code, came from the Mindbg project on Codeplex. Another change is that when using the MDbgEngine.CreateProcess to launch a process in the debugger, do not supply a null as the final argument. This does not work any more because GetCORVersion always returns "v2.0.50727" as the function has been deprecated in .NET v4. What's worse is that on a system with only .NET 4, the user will be prompted to download and install .NET v2! Not nice! This works much better: proc = m_Debugger.CreateProcess(ProcessName, ProcessArgs, DebugModeFlag.Default,String.Format("v{0}.{1}.{2}",System.Environment.Version.Major,System.Environment.Version.Minor,System.Environment.Version.Build)); Microsoft "unofficially" plan on updating the MDbg samples soon, but if you have an MDbg-based application, you can get it working right now by changing one method a bit and adding a few new interfaces (ICLRMetaHost, IEnumUnknown, and ICLRRuntimeInfo). The new, non-legacy implementation of MDbg Engine will add new, interesting features like dump-file support and by association I assume garbage-collection/managed object stats, so it will be well worth looking into if you want to extend the functionality of a managed debugger going forward.

    Read the article

  • Overriding SQLMembershipProvider in C#

    - by vikp
    Hi, Is there built in methods into .net framework to do the following: Get role GUID from user name/user GUID Get role name from role GUID So far I have been sending queries to the asp_roles and asp_users tables to obtain that information and I'm wondering if there is a nicer way of doing this? I have the following methods that I store in the ASPUtilities class: getRoleGUID(guid userGuid) { LINQ joins } getRoleGuid(string userName) { LINQ joins } getRoleName(guid roleGuid) { LINQ joins } Thank you EDIT: I have just looked into extending SQLMembershipProvider examples. Few examples completely override the SQLMembershipProvider, but I think what I'm interested is just adding few extra methods to deal with the roles by using LINQ. Is this feasible?

    Read the article

  • Overriding SQLMembershipProvider

    - by vikp
    Is there built in methods into .net framework to do the following: Get role GUID from user name/user GUID Get role name from role GUID So far I have been sending queries to the asp_roles and asp_users tables to obtain that information and I'm wondering if there is a nicer way of doing this? I have the following methods that I store in the ASPUtilities class: getRoleGUID(guid userGuid) { LINQ joins } getRoleGuid(string userName) { LINQ joins } getRoleName(guid roleGuid) { LINQ joins } EDIT: I have just looked into extending SQLMembershipProvider examples. Few examples completely override the SQLMembershipProvider, but I think what I'm interested is just adding few extra methods to deal with the roles by using LINQ. Is this feasible?

    Read the article

  • Building a plug-in for Windows Live Writer

    - by mbcrump
    This tutorial will show you how to build a plug-in for Windows Live Writer. Windows Live Writer is a blogging tool that Microsoft provides for free. It includes an open API for .NET developers to create custom plug-ins. In this tutorial, I will show you how easy it is to build one. Open VS2008 or VS2010 and create a new project. Set the target framework to 2.0, Application Type to Class Library and give it a name. In this tutorial, we are going to create a plug-in that generates a twitter message with your blog post name and a TinyUrl link to the blog post.  It will do all of this automatically after you publish your post. Once, we have a new projected created. We need to setup the references. Add a reference to the WindowsLive.Writer.Api.dll located in the C:\Program Files (x86)\Windows Live\Writer\ folder, if you are using X64 version of Windows. You will also need to add a reference to System.Windows.Forms System.Web from the .NET tab as well. Once that is complete, add your “using” statements so that it looks like whats shown below: Live Writer Plug-In "Using" using System; using System.Collections.Generic; using System.Text; using WindowsLive.Writer.Api; using System.Web; Now, we are going to setup some build events to make it easier to test our custom class. Go into the Properties of your project and select Build Events, click edit the Post-build and copy/paste the following line: XCOPY /D /Y /R "$(TargetPath)" "C:\Program Files (x86)\Windows Live\Writer\Plugins\" Your screen should look like the one pictured below: Next, we are going to launch an external program on debug. Click the debug tab and enter C:\Program Files (x86)\Windows Live\Writer\WindowsLiveWriter.exe Your screen should look like the one pictured below:   Now we have a blank project and we need to add some code. We start with adding the attributes for the Live Writer Plugin. Before we get started creating the Attributes, we need to create a GUID. This GUID will uniquely identity our plug-in. So, to create a GUID follow the steps in VS2008/2010. Click Tools from the VS Menu ->Create GUID It will generate a GUID like the one listed below: GUID <Guid("56ED8A2C-F216-420D-91A1-F7541495DBDA")> We only want what’s inside the quotes, so your final product should be: "56ED8A2C-F216-420D-91A1-F7541495DBDA". Go ahead and paste this snipped into your class just above the public class. Live Writer Plug-In Attributes [WriterPlugin("56ED8A2C-F216-420D-91A1-F7541495DBDA",    "Generate Twitter Message",    Description = "After your new post has been published, this plug-in will attempt to generate a Twitter status messsage with the Title and TinyUrl link.",    HasEditableOptions = false,    Name = "Generate Twitter Message",    PublisherUrl = "http://michaelcrump.net")] [InsertableContentSource("Generate Twitter Message")] So far, it should look like the following: Next, we need to implement the PublishNotifcationHook class and override the OnPostPublish. I’m not going to dive into what the code is doing as you should be able to follow pretty easily. The code below is the entire code used in the project. PublishNotificationHook public class Class1 :  PublishNotificationHook  {      public override void OnPostPublish(System.Windows.Forms.IWin32Window dialogOwner, IProperties properties, IPublishingContext publishingContext, bool publish)      {          if (!publish) return;          if (string.IsNullOrEmpty(publishingContext.PostInfo.Permalink))          {              PluginDiagnostics.LogError("Live Tweet didn't execute, due to blank permalink");          }          else          {                var strBlogName = HttpUtility.UrlEncode("#blogged : " + publishingContext.PostInfo.Title);  //Blog Post Title              var strUrlFinal = getTinyUrl(publishingContext.PostInfo.Permalink); //Blog Permalink URL Converted to TinyURL              System.Diagnostics.Process.Start("http://twitter.com/home?status=" + strBlogName + strUrlFinal);            }      } We are going to go ahead and create a method to create the short url (tinyurl). TinyURL Helper Method private static string getTinyUrl(string url) {     var cmpUrl = System.Globalization.CultureInfo.InvariantCulture.CompareInfo;     if (!cmpUrl.IsPrefix(url, "http://tinyurl.com"))     {         var address = "http://tinyurl.com/api-create.php?url=" + url;         var client = new System.Net.WebClient();         return (client.DownloadString(address));     }     return (url); } Go ahead and build your project, it should have copied the .DLL into the Windows Live Writer Plugin Directory. If it did not, then you will want to check your configuration. Once that is complete, open Windows Live Writer and select Tools-> Options-> Plug-ins and enable your plug-in that you just created. Your screen should look like the one pictured below: Go ahead and click OK and publish your blog post. You should get a pop-up with the following: Hit OK and It should open a Twitter and either ask for a login or fill in your status as shown below:   That should do it, you can do so many other things with the API. I suggest that if you want to build something really useful consult the MSDN pages. This plug-in that I created was perfect for what I needed and I hope someone finds it useful.

    Read the article

  • Adventures in Windows 8: Solving activation errors

    - by Laurent Bugnion
    Note: I tagged this article with “MVVM” because I got a few support requests for MVVM Light regarding this exact issue. In fact it is a Windows 8 issue and has nothing to do with MVVM Light per se… Sometimes when you work on a Windows 8 app, you will get a very annoying issue when starting the app. In that case, the app doesn’t not even start past the Splash screen. Putting a breakpoint in App.xaml.cs doesn’t help because the app doesn’t even reach that point! So what exactly is happening? Well when a Windows 8 app starts, the system is performing a few check first. One of the checks, for instance, is to see if an app with the same package ID is already available. The package ID is a unique value set in the package manifest. In the Solution Explorer, double click on Package.appxmanifest. This opens the manifest in a special editor Click on the Packaging tab See the GUID under Package Name. This is the unique ID I am talking about. If there is a conflict (i.e. if an app is already installed with the exact same ID), Windows will warm the user that the app is already installed. However when you are in the process of developing an app, you install and uninstall the same app many many times (every time that you start in Visual Studio), and sometimes some issues arise, for instance failing to uninstall the app before starting the new instance of the same app. First step if you get such an error When the application fails to start past the splash screen, the first step is to identify what kind of error happened. In my experience the “already installed” is by far the most frequent (in fact I never had another such error), but it can be something else. An annoying thing is that the popup that shows the error is usually started below the Windows 8 app, and so you don’t even see it! This is especially true if you run this in the Simulator. In that case, do the following: Press on the Simulator’s home button, then press on the Desktop tile on the Start menu. The error popup should be shown on the desktop. If your applications runs on the Local machine, you also do the same and press the Windows button, and then from the Start menu press the Desktop tile. Deployment error in Studio Sometimes the same error causes Visual Studio to fail launching the application at all with a deployment error. This is a better case, because at least it is clear that there is an issue. In that case, write down the code that is shown in the Error window (for instance 0x80073D05 in the example below). Once you have the error code, go to the “Troubleshooting packaging, deployment, and query of Windows Store apps” page and look up the code in question. In my case, the error was “ERROR_DELETING_EXISTING_APPLICATIONDATA_STORE_FAILED”, “An error occurred while deleting the package's previously existing application data.” Solving the “ERROR_DELETING_EXISTING_APPLICATIONDATA_STORE_FAILED” issue Update: Before trying the below, you can also try the simple steps: Exit Visual Studio Go to the Start menu Locate your app’s tile. It should be visible in the Start menu directly, towards the far end on the right. Right click the tile and select Uninstall from the App Bar. Restart Visual Studio and try again. Sometimes it helps. If it doesn’t, then try the following: In order to solve the case where Windows, for any reason, fails to delete the existing application before starting the new instance, follow the steps: Open the Package.appxmanifest in Visual Studio Open the Packaging tab. Change the Package name. For tests you can just try to change the last character of the GUID, though I would recommend creating a brand new GUID. Press Start Type GUID Start the GUID Generator application Select Registry Format Press Copy. Paste the new GUID in place of the Package Name in Visual Studio Important: don’t forget to remove the curly brackets at the beginning and at the end of the newly pasted GUID. Then you just have to cross your fingers and start the application again… If it works, celebrate. if it doesn’t work… well at this point I am not sure so good luck with that ;) Happy coding, Laurent   Laurent Bugnion (GalaSoft) Subscribe | Twitter | Facebook | Flickr | LinkedIn

    Read the article

  • Is it a problem if i query again and again to SQL Server 2005 and 2000?

    - by learner
    Window app i am constructing is for very low end machines (Celeron with max 128 RAM). From the following two approaches which one is the best (I don't want that application becomes memory hog for low end machines):- Approach One:- Query the database Select GUID from Table1 where DateTime <= @givendate which is returning me more than 300 thousands records (but only one field i.e. GUID - 300 thousands GUIDs). Now running a loop to achieve next process of this software based on GUID. Second Approach:- Query the database Select Top 1 GUID from Table1 where DateTime <= @givendate with top 1 again and again until all 300 thousands records done. It will return me only one GUID at a time, and I can do my next step of operation. What do you suggest which approach will use the less Memory Resources?? (Speed / performance is not the issue here).

    Read the article

  • Minimal-change algorithm which maximises 'swapping'

    - by Kim Bastin
    This is a question on combinatorics from a non-mathematician, so please try to bear with me! Given an array of n distinct characters, I want to generate subsets of k characters in a minimal-change order, i.e. an order in which generation n+1 contains exactly one character that was not in generation n. That's not too hard in itself. However, I also want to maximise the number of cases in which the character that is swapped out in generation n+1 is the same character that was swapped in in generation n. To illustrate, for n=7, k=3: abc abd abe* abf* abg* afg aeg* adg* acg* acd ace* acf* aef adf* ade bde bdf bef bcf* bce bcd* bcg* bdg beg* bfg* cfg ceg* cdg* cde cdf* cef def deg dfg efg The asterisked strings indicate the case I want to maximise; e.g. the e that is new in generation 3, abe, replaces a d that was new in generation 2, abd. It doesn't seem possible to have this happen in every generation, but I want it to happen as often as possible. Typical array sizes that I use are 20-30 and subset sizes around 5-8. I'm using an odd language, Icon (or actually its derivative Unicon), so I don't expect anyone to post code that I can used directly. But I will be grateful for answers or hints in pseudo-code, and will do my best to translate C etc. Also, I have noticed that problems of this kind are often discussed in terms of arrays of integers, and I can certainly apply solutions posted in such terms to my own problem. Thanks Kim Bastin

    Read the article

  • Problems with native Win32api RichEdit control and its IRichEditOle interface

    - by Michael
    Hi All! As part of writing custom command (dll with class that implements Interwoven command interface) for one of Interwoven Worksite dialog boxes,I need to extract information from RichEdit textbox. The only connection to the existing dialog box is its HWND handle; Seemingly trivial task , but I got stuck : Using standard win32 api functions (like GetDlgItemText) returns empty string. After using Spy++ I noticed that the dialog box gets IRichEditOle interface and seems to encapsulate the string into OLE object. Here is what I tried to do: IRichEditOle richEditOleObj = null; IntPtr ppv = IntPtr.Zero; Guid guid = new Guid("00020D00-0000-0000-c000-000000000046"); Marshal.QueryInterface(pRichEdit, ref guid, out ppv); richEditOleObj = (IRichEditOle)Marshal.GetTypedObjectForIUnknown(ppv,typeof(IRichEditOle)); judging by GetObjectCount() method of the interface there is exactly one object in the textbox - most likely the string I need to extract. I used GetObject() method and got IOleObject interface via QueryInterface : if (richEditOleObj.GetObject(0, reObject, GetObjectOptions.REO_GETOBJ_ALL_INTERFACES) == 0) //S_OK { IntPtr oleObjPpv = IntPtr.Zero; try { IOleObject oleObject = null; Guid objGuid = new Guid("00000112-0000-0000-C000-000000000046"); Marshal.QueryInterface(reObject.poleobj, ref objGuid, out oleObjPpv); oleObject = (IOleObject)Marshal.GetTypedObjectForIUnknown(oleObjPpv, typeof(IOleObject)); To negate other possibilites I tried to QueryInteface IRichEditOle to ITextDocument but this also returned empty string; tried to send EM_STREAMOUT message and read buffer returned from callback - returned empty buffer. And on this point I got stuck. Googling didn't help much - couldn't find anything that was relevant to my issue - it seems that vast majority of examples on the net about IRichEditOle and RichEdit revolve around inserting bitmap into RichEdit control... Now since I know only basic stuff about COM and OLE , I guess I am missing something important here. I would appreciate any thoughts suggestions or remarks.

    Read the article

  • Generic version control strategy for select table data within a heavily normalized database

    - by leppie
    Hi Sorry for the long winded title, but the requirement/problem is rather specific. With reference to the following sample (but very simplified) structure (in psuedo SQL), I hope to explain it a bit better. TABLE StructureName { Id GUID PK, Name varchar(50) NOT NULL } TABLE Structure { Id GUID PK, ParentId GUID (FK to Structure), NameId GUID (FK to StructureName) NOT NULL } TABLE Something { Id GUID PK, RootStructureId GUID (FK to Structure) NOT NULL } As one can see, Structure is a simple tree structure (not worried about ordering of children for the problem). StructureName is a simplification of a translation system. Finally 'Something' is simply something referencing the tree's root structure. This is just one of many tables that need to be versioned, but this one serves as a good example for most cases. There is a requirement to version to any changes to the name and/or the tree 'layout' of the Structure table. Previous versions should always be available. There seems to be a few possibilities to tackle this issue, like copying the entire structure, but most approaches causes one to 'loose' referential integrity. Example if one followed this approach, one would have to make a duplicate of the 'Something' record, given that the root structure will be a new record, and have a new ID. Other avenues of possible solutions are looking into how Wiki's handle this or go a lot further and look how proper version control systems work. Currently, I feel a bit clueless how to proceed on this in a generic way. Any ideas will be greatly appreciated. Thanks leppie

    Read the article

  • Need suggestion for Mutiple Windows application design

    - by King Chan
    This was previously posted in StackOverflow, I just moved to here... I am using VS2008, MVVM, WPF, Prism to make a mutiple window CRM Application. I am using MidWinow in my MainWindow, I want Any ViewModel would able to make request to MainWindow to create/add/close MidChildWindow, ChildWindow(from WPF Toolkit), Window (the Window type). ViewModel can get the DialogResult from the ChildWindow its excutes. MainWindow have control on all opened window types. Here is my current approach: I made Dictionary of each of the windows type and stores them into MainWindow class. For 1, i.e in a CustomerInformationView, its CustomerInformationViewModel can execute EditCommand and use EventAggregator to tell MainWindow to open a new ChildWindow. CustomerInformationViewModel: CustomerEditView ceView = new CustomerEditView (); CustomerEditViewModel ceViewModel = CustomerEditViewModel (); ceView.DataContext = ceViewModel; ChildWindow cWindow = new ChildWindow(); cWindow.Content = ceView; MainWindow.EvntAggregator.GetEvent<NewWindowEvent>().Publish(new WindowEventArgs(ceViewModel.ViewModeGUID, cWindow )); cWindow.Show(); Notice that all my ViewModel will generates a Guid for help identifies the ChildWindow from MainWindow's dictionary. Since I will only be using 1 View 1 ViewModel for every Window. For 2. In CustomerInformationViewModel I can get DialogResult by OnClosing event from ChildWindow, in CustomerEditViewModel can use Guid to tell MainWindow to close the ChildWindow. Here is little question and problems: Is it good idea to use Guid here? Or should I use HashKey from ChildWindow? My MainWindows contains windows reference collections. So whenever window close, it will get notifies to remove from the collection by OnClosing event. But all the Windows itself doesn't know about its associated Guid, so when I remove it, I have to search for every KeyValuePair to compares... I still kind of feel wrong associate ViewModel's Guid for ChildWindow, it would make more sense if ChildWindow has it own ID then ViewModel associate with it... But most important, is there any better approach on this design? How can I improve this better?

    Read the article

  • SCVMM – Round 2 – How to create a Private Cloud using PowerShell

    - by Waclaw Chrabaszcz
    Originally posted on: http://geekswithblogs.net/Wchrabaszcz/archive/2013/06/28/scvmm--round-2--how-to-create-a-private.aspxHave you ever seen "A Bridge too far" movie? To not to wake up a click too far, it is good to script some tasks. Yes of course we can follow wizards, but some of us want to be warriorsJ. A small tip, take a look on credentials and system GUID examples. I don't know how about you, but for me it will be really useful in the future.    # credents$credential = Get-CredentialNew-SCRunAsAccount -Name "TESTDOMAIN\Administrator" -Credential $credential #storage $opsMgrServerCredential = Get-SCRunAsAccount -Name "TESTDOMAIN\Administrator"New-SCStorageClassification -Name "Bronze" -Description "" –RunAsynchronouslyNew-SCStorageClassification -Name "Silver" -Description "" –RunAsynchronouslyNew-SCStorageClassification -Name "Gold" -Description "" –RunAsynchronously # add a shared storageFind-SCComputer -ComputerName "dc.TESTDOMAIN.net"Add-SCStorageProvider -AddWindowsNativeWmiProvider -Name "dc.TESTDOMAIN.net" -RunAsAccount $opsMgrServerCredential -ComputerName "dc.TESTDOMAIN.net"$fileServer = Get-SCStorageFileServer "dc.TESTDOMAIN.net"$fileShares = @()$fileShares += Get-SCStorageFileShare -Name "VMMLibrary"Set-SCStorageFileServer -StorageFileServer $fileServer -AddStorageFileShareToManagement $fileShares –RunAsynchronously #fabric network$logicalNetwork = New-SCLogicalNetwork -Name "TESTDOMAIN-Service-Network" -LogicalNetworkDefinitionIsolation $false -EnableNetworkVirtualization $true -UseGRE $true -IsPVLAN $false$allHostGroups = @()$allHostGroups += Get-SCVMHostGroup -Name "All Hosts"$allSubnetVlan = @()$allSubnetVlan += New-SCSubnetVLan -Subnet "10.0.0.0/24" -VLanID 0New-SCLogicalNetworkDefinition -Name "TESTDOMAIN-Service-Network_0" -LogicalNetwork $logicalNetwork -VMHostGroup $allHostGroups -SubnetVLan $allSubnetVlan #IP pool$logicalNetwork = Get-SCLogicalNetwork -Name "TESTDOMAIN-Service-Network"$logicalNetworkDefinition = Get-SCLogicalNetworkDefinition -LogicalNetwork $logicalNetwork -Name "TESTDOMAIN-Service-Network_0" # Gateways$allGateways = @()$allGateways += New-SCDefaultGateway -IPAddress "10.0.0.1" –Automatic# DNS servers $allDnsServer = @("10.0.0.1")# DNS suffixes$allDnsSuffixes = @("TESTDOMAIN.net")# WINS servers$allWinsServers = @()New-SCStaticIPAddressPool -Name "TESTDOMAIN-Service-Network" -LogicalNetworkDefinition $logicalNetworkDefinition -Subnet "10.0.0.0/24" -IPAddressRangeStart "10.0.0.51" -IPAddressRangeEnd "10.0.0.75" -DefaultGateway $allGateways -DNSServer $allDnsServer -DNSSuffix "" -DNSSearchSuffix $allDnsSuffixes –RunAsynchronously #Hyper-V Virtual Networks$logicalNetwork = Get-SCLogicalNetwork -Name "TESTDOMAIN-Service-Network" $vmNetwork = New-SCVMNetwork -Name "TESTDOMAIN-VMN" -LogicalNetwork $logicalNetwork -IsolationType "WindowsNetworkVirtualization" -CAIPAddressPoolType "IPV4" -PAIPAddressPoolType "IPV4"Write-Output $vmNetwork$subnet = New-SCSubnetVLan -Subnet "10.0.0.0/24"New-SCVMSubnet -Name "Con-SN" -VMNetwork $vmNetwork -SubnetVLan $subnet # bind VLAN with the Network Adapter$vmHost = Get-SCVMHost -ComputerName "VMM01.TESTDOMAIN.net"$vmHostNetworkAdapter = Get-SCVMHostNetworkAdapter -VMHost $vmHost #-Name "Intel 21140-Based PCI Fast Ethernet Adapter (Emulated)"Set-SCVMHostNetworkAdapter -VMHostNetworkAdapter $vmHostNetworkAdapter -Description "" -AvailableForPlacement $true -UsedForManagement $true $logicalNetwork = Get-SCLogicalNetwork -Name "TESTDOMAIN-Service-Network" Set-SCVMHostNetworkAdapter -VMHostNetworkAdapter $vmHostNetworkAdapter -AddOrSetLogicalNetwork $logicalNetworkSet-SCVMHost -VMHost $vmHost -RunAsynchronously -NumaSpanningEnabled $true #Create a Private Cloud$Guid = [System.Guid]::NewGuid()Set-SCCloudCapacity -JobGroup $Guid -UseCustomQuotaCountMaximum $false -UseMemoryMBMaximum $false -UseCPUCountMaximum $false -UseStorageGBMaximum $false -UseVMCountMaximum $false -CustomQuotaCount 10 -MemoryMB 10240 -CPUCount 10 -StorageGB 386 -VMCount 10$resources = @()$resources += Get-SCLogicalNetwork -Name "TESTDOMAIN-Service-Network"$resources += Get-SCLoadBalancer -Manufacturer "Microsoft"$readonlyLibraryShares = @()$readonlyLibraryShares += Get-SCLibraryShare | where { $_.LibraryServer.Name -eq "dc.TESTDOMAIN.net" -and $_.Name -eq "VMMLibrary" }$addCapabilityProfiles = @()$addCapabilityProfiles += Get-SCCapabilityProfile -Name "Hyper-V"$Guid2 = [System.Guid]::NewGuid()Set-SCCloud -JobGroup $Guid2 -RunAsynchronously -AddCloudResource $resources -AddReadOnlyLibraryShare $readonlyLibraryShares -AddCapabilityProfile $addCapabilityProfiles$hostGroups = @()$hostGroups += Get-SCVMHostGroup -Name "TESTDOMAIN"New-SCCloud -VMHostGroup $hostGroups -Name "TESTDOMAIN-Cloud" -Description "" –RunAsynchronously

    Read the article

  • Tuning garbage collections for low latency

    - by elec
    I'm looking for arguments as to how best to size the young generation (with respect to the old generation) in an environment where low latency is critical. My own testing tends to show that latency is lowest when the young generation is fairly large (eg. -XX:NewRatio <3), however I cannot reconcile this with the intuition that the larger the young generation the more time it should take to garbage collect. The application runs on linux, jdk 6 before update 14, i.e G1 not available.

    Read the article

  • Use pt-table-sync to setup a new MySQL DB

    - by Generation D Systems
    I have 2 hosts (A and B). B contains a MySQL server with a database called mydb, and A contains a MySQL server with nothing (fresh install). I want to replicate the entire mydb from B to A, by running a script on A (I do not have shell access to B). Can I run this on A: pt-table-sync --execute h=b.mydomain.com,D=mydb h=a.mydomain.com I've read the docs but don't get a 100% comfort feeling (perhaps because of all the warnings about damaging your data if you don't know what you're doing). Will this work? as well, is h=a.mydomin.com necessary? (Will it route all traffic back in/out the local NIC?) can I use localhost or nothing at all?

    Read the article

  • Using mongodump with an auth enabled mongodb server

    - by bb-generation
    I'm trying to do a daily backup of my mongodb server (auth enabled) using the mongodump tool. mongodump provides two parameters to set the credentials: -u [ --username ] arg username -p [ --password ] arg password Unfortunately they don't provide any parameter to read the password from stdin. Therefore everytime I run this command, everyone on the server can read the password (e.g. by using ps aux). The only workaround I have found is stopping the database and directly accessing the database files using the --dbpath parameter. Is there any other solution which allows me to backup the mongodb database without stopping the server and without "publishing" my password? I am using Debian squeeze 6.0.5 amd64 with mongodb 1.4.4-3.

    Read the article

< Previous Page | 37 38 39 40 41 42 43 44 45 46 47 48  | Next Page >