Search Results

Search found 8937 results on 358 pages for 'disk defragmenting'.

Page 42/358 | < Previous Page | 38 39 40 41 42 43 44 45 46 47 48 49  | Next Page >

  • can't save or create files in external hard disk

    - by Rodniko
    i formatted my computer and installed new win7. i connected my external hard disk (usb connector) and i have some kind of permission problem. i can't save files after opening them and right clicking and choosing "new" shows that i can only create folders. what is wrong ? why doesn't the external hd doesn't have permission and how do i cahnge it? in microsoft they probably thought: "hmmm.... how would i make it difficult for the user to use our product..." , "we will have to make the difficulty as soon as the windows is installed...." " but how would we guarantee 100% for the user to have problems? "oh yhe! block creating files and saving them, yes!" i'm so tired of those guys... my HD is half a Terra, changing ownership of all the files inside will take a couple of hours , i need other ideas... if any...

    Read the article

  • Oracle Solaris: Zones on Shared Storage

    - by Jeff Victor
    Oracle Solaris 11.1 has several new features. At oracle.com you can find a detailed list. One of the significant new features, and the most significant new feature releated to Oracle Solaris Zones, is casually called "Zones on Shared Storage" or simply ZOSS (rhymes with "moss"). ZOSS offers much more flexibility because you can store Solaris Zones on shared storage (surprise!) so that you can perform quick and easy migration of a zone from one system to another. This blog entry describes and demonstrates the use of ZOSS. ZOSS provides complete support for a Solaris Zone that is stored on "shared storage." In this case, "shared storage" refers to fiber channel (FC) or iSCSI devices, although there is one lone exception that I will demonstrate soon. The primary intent is to enable you to store a zone on FC or iSCSI storage so that it can be migrated from one host computer to another much more easily and safely than in the past. With this blog entry, I wanted to make it easy for you to try this yourself. I couldn't assume that you have a SAN available - which is a good thing, because neither do I! What could I use, instead? [There he goes, foreshadowing again... -Ed.] Developing this entry reinforced the lesson that the solution to every lab problem is VirtualBox. Oracle VM VirtualBox (its formal name) helps here in a couple of important ways. It offers the ability to easily install multiple copies of Solaris as guests on top of any popular system (Microsoft Windows, MacOS, Solaris, Oracle Linux (and other Linuxes) etc.). It also offers the ability to create a separate virtual disk drive (VDI) that appears as a local hard disk to a guest. This virtual disk can be moved very easily from one guest to another. In other words, you can follow the steps below on a laptop or larger x86 system. Please note that the ability to use ZOSS to store a zone on a local disk is very useful for a lab environment, but not so useful for production. I do not suggest regularly moving disk drives among computers. In the method I describe below, that virtual hard disk will contain the zone that will be migrated among the (virtual) hosts. In production, you would use FC or iSCSI LUNs instead. The zonecfg(1M) man page details the syntax for each of the three types of devices. Why Migrate? Why is the migration of virtual servers important? Some of the most common reasons are: Moving a workload to a different computer so that the original computer can be turned off for extensive maintenance. Moving a workload to a larger system because the workload has outgrown its original system. If the workload runs in an environment (such as a Solaris Zone) that is stored on shared storage, you can restore the service of the workload on an alternate computer if the original computer has failed and will not reboot. You can simplify lifecycle management of a workload by developing it on a laptop, migrating it to a test platform when it's ready, and finally moving it to a production system. Concepts For ZOSS, the important new concept is named "rootzpool". You can read about it in the zonecfg(1M) man page, but here's the short version: it's the backing store (hard disk(s), or LUN(s)) that will be used to make a ZFS zpool - the zpool that will hold the zone. This zpool: contains the zone's Solaris content, i.e. the root file system does not contain any content not related to the zone can only be mounted by one Solaris instance at a time Method Overview Here is a brief list of the steps to create a zone on shared storage and migrate it. The next section shows the commands and output. You will need a host system with an x86 CPU (hopefully at least a couple of CPU cores), at least 2GB of RAM, and at least 25GB of free disk space. (The steps below will not actually use 25GB of disk space, but I don't want to lead you down a path that ends in a big sign that says "Your HDD is full. Good luck!") Configure the zone on both systems, specifying the rootzpool that both will use. The best way is to configure it on one system and then copy the output of "zonecfg export" to the other system to be used as input to zonecfg. This method reduces the chances of pilot error. (It is not necessary to configure the zone on both systems before creating it. You can configure this zone in multiple places, whenever you want, and migrate it to one of those places at any time - as long as those systems all have access to the shared storage.) Install the zone on one system, onto shared storage. Boot the zone. Provide system configuration information to the zone. (In the Real World(tm) you will usually automate this step.) Shutdown the zone. Detach the zone from the original system. Attach the zone to its new "home" system. Boot the zone. The zone can be used normally, and even migrated back, or to a different system. Details The rest of this shows the commands and output. The two hostnames are "sysA" and "sysB". Note that each Solaris guest might use a different device name for the VDI that they share. I used the device names shown below, but you must discover the device name(s) after booting each guest. In a production environment you would also discover the device name first and then configure the zone with that name. Fortunately, you can use the command "zpool import" or "format" to discover the device on the "new" host for the zone. The first steps create the VirtualBox guests and the shared disk drive. I describe the steps here without demonstrating them. Download VirtualBox and install it using a method normal for your host OS. You can read the complete instructions. Create two VirtualBox guests, each to run Solaris 11.1. Each will use its own VDI as its root disk. Install Solaris 11.1 in each guest.Install Solaris 11.1 in each guest. To install a Solaris 11.1 guest, you can either download a pre-built VirtualBox guest, and import it, or install Solaris 11.1 from the "text install" media. If you use the latter method, after booting you will not see a windowing system. To install the GUI and other important things, login and run "pkg install solaris-desktop" and take a break while it installs those important things. Life is usually easier if you install the VirtualBox Guest Additions because then you can copy and paste between the host and guests, etc. You can find the guest additions in the folder matching the version of VirtualBox you are using. You can also read the instructions for installing the guest additions. To create the zone's shared VDI in VirtualBox, you can open the storage configuration for one of the two guests, select the SATA controller, and click on the "Add Hard Disk" icon nearby. Choose "Create New Disk" and specify an appropriate path name for the file that will contain the VDI. The shared VDI must be at least 1.5 GB. Note that the guest must be stopped to do this. Add that VDI to the other guest - using its Storage configuration - so that each can access it while running. The steps start out the same, except that you choose "Choose Existing Disk" instead of "Create New Disk." Because the disk is configured on both of them, VirtualBox prevents you from running both guests at the same time. Identify device names of that VDI, in each of the guests. Solaris chooses the name based on existing devices. The names may be the same, or may be different from each other. This step is shown below as "Step 1." Assumptions In the example shown below, I make these assumptions. The guest that will own the zone at the beginning is named sysA. The guest that will own the zone after the first migration is named sysB. On sysA, the shared disk is named /dev/dsk/c7t2d0 On sysB, the shared disk is named /dev/dsk/c7t3d0 (Finally!) The Steps Step 1) Determine the name of the disk that will move back and forth between the systems. root@sysA:~# format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c7t0d0 /pci@0,0/pci8086,2829@d/disk@0,0 1. c7t2d0 /pci@0,0/pci8086,2829@d/disk@2,0 Specify disk (enter its number): ^D Step 2) The first thing to do is partition and label the disk. The magic needed to write an EFI label is not overly complicated. root@sysA:~# format -e c7t2d0 selecting c7t2d0 [disk formatted] FORMAT MENU: ... format fdisk No fdisk table exists. The default partition for the disk is: a 100% "SOLARIS System" partition Type "y" to accept the default partition, otherwise type "n" to edit the partition table. n SELECT ONE OF THE FOLLOWING: ... Enter Selection: 1 ... G=EFI_SYS 0=Exit? f SELECT ONE... ... 6 format label ... Specify Label type[1]: 1 Ready to label disk, continue? y format quit root@sysA:~# ls /dev/dsk/c7t2d0 /dev/dsk/c7t2d0 Step 3) Configure zone1 on sysA. root@sysA:~# zonecfg -z zone1 Use 'create' to begin configuring a new zone. zonecfg:zone1 create create: Using system default template 'SYSdefault' zonecfg:zone1 set zonename=zone1 zonecfg:zone1 set zonepath=/zones/zone1 zonecfg:zone1 add rootzpool zonecfg:zone1:rootzpool add storage dev:dsk/c7t2d0 zonecfg:zone1:rootzpool end zonecfg:zone1 exit root@sysA:~# oot@sysA:~# zonecfg -z zone1 info zonename: zone1 zonepath: /zones/zone1 brand: solaris autoboot: false bootargs: file-mac-profile: pool: limitpriv: scheduling-class: ip-type: exclusive hostid: fs-allowed: anet: ... rootzpool: storage: dev:dsk/c7t2d0 Step 4) Install the zone. This step takes the most time, but you can wander off for a snack or a few laps around the gym - or both! (Just not at the same time...) root@sysA:~# zoneadm -z zone1 install Created zone zpool: zone1_rpool Progress being logged to /var/log/zones/zoneadm.20121022T163634Z.zone1.install Image: Preparing at /zones/zone1/root. AI Manifest: /tmp/manifest.xml.RXaycg SC Profile: /usr/share/auto_install/sc_profiles/enable_sci.xml Zonename: zone1 Installation: Starting ... Creating IPS image Startup linked: 1/1 done Installing packages from: solaris origin: http://pkg.us.oracle.com/support/ DOWNLOAD PKGS FILES XFER (MB) SPEED Completed 183/183 33556/33556 222.2/222.2 2.8M/s PHASE ITEMS Installing new actions 46825/46825 Updating package state database Done Updating image state Done Creating fast lookup database Done Installation: Succeeded Note: Man pages can be obtained by installing pkg:/system/manual done. Done: Installation completed in 1696.847 seconds. Next Steps: Boot the zone, then log into the zone console (zlogin -C) to complete the configuration process. Log saved in non-global zone as /zones/zone1/root/var/log/zones/zoneadm.20121022T163634Z.zone1.install Step 5) Boot the Zone. root@sysA:~# zoneadm -z zone1 boot Step 6) Login to zone's console to complete the specification of system information. root@sysA:~# zlogin -C zone1 Answer the usual questions and wait for a login prompt. Then you can end the console session with the usual "~." incantation. Step 7) Shutdown the zone so it can be "moved." root@sysA:~# zoneadm -z zone1 shutdown Step 8) Detach the zone so that the original global zone can't use it. root@sysA:~# zoneadm list -cv ID NAME STATUS PATH BRAND IP 0 global running / solaris shared - zone1 installed /zones/zone1 solaris excl root@sysA:~# zpool list NAME SIZE ALLOC FREE CAP DEDUP HEALTH ALTROOT rpool 17.6G 11.2G 6.47G 63% 1.00x ONLINE - zone1_rpool 1.98G 484M 1.51G 23% 1.00x ONLINE - root@sysA:~# zoneadm -z zone1 detach Exported zone zpool: zone1_rpool Step 9) Review the result and shutdown sysA so that sysB can use the shared disk. root@sysA:~# zpool list NAME SIZE ALLOC FREE CAP DEDUP HEALTH ALTROOT rpool 17.6G 11.2G 6.47G 63% 1.00x ONLINE - root@sysA:~# zoneadm list -cv ID NAME STATUS PATH BRAND IP 0 global running / solaris shared - zone1 configured /zones/zone1 solaris excl root@sysA:~# init 0 Step 10) Now boot sysB and configure a zone with the parameters shown above in Step 1. (Again, the safest method is to use "zonecfg ... export" on sysA as described in section "Method Overview" above.) The one difference is the name of the rootzpool storage device, which was shown in the list of assumptions, and which you must determine by booting sysB and using the "format" or "zpool import" command. When that is done, you should see the output shown next. (I used the same zonename - "zone1" - in this example, but you can choose any valid zonename you want.) root@sysB:~# zoneadm list -cv ID NAME STATUS PATH BRAND IP 0 global running / solaris shared - zone1 configured /zones/zone1 solaris excl root@sysB:~# zonecfg -z zone1 info zonename: zone1 zonepath: /zones/zone1 brand: solaris autoboot: false bootargs: file-mac-profile: pool: limitpriv: scheduling-class: ip-type: exclusive hostid: fs-allowed: anet: linkname: net0 ... rootzpool: storage: dev:dsk/c7t3d0 Step 11) Attaching the zone automatically imports the zpool. root@sysB:~# zoneadm -z zone1 attach Imported zone zpool: zone1_rpool Progress being logged to /var/log/zones/zoneadm.20121022T184034Z.zone1.attach Installing: Using existing zone boot environment Zone BE root dataset: zone1_rpool/rpool/ROOT/solaris Cache: Using /var/pkg/publisher. Updating non-global zone: Linking to image /. Processing linked: 1/1 done Updating non-global zone: Auditing packages. No updates necessary for this image. Updating non-global zone: Zone updated. Result: Attach Succeeded. Log saved in non-global zone as /zones/zone1/root/var/log/zones/zoneadm.20121022T184034Z.zone1.attach root@sysB:~# zoneadm -z zone1 boot root@sysB:~# zlogin zone1 [Connected to zone 'zone1' pts/2] Oracle Corporation SunOS 5.11 11.1 September 2012 Step 12) Now let's migrate the zone back to sysA. Create a file in zone1 so we can verify it exists after we migrate the zone back, then begin migrating it back. root@zone1:~# ls /opt root@zone1:~# touch /opt/fileA root@zone1:~# ls -l /opt/fileA -rw-r--r-- 1 root root 0 Oct 22 14:47 /opt/fileA root@zone1:~# exit logout [Connection to zone 'zone1' pts/2 closed] root@sysB:~# zoneadm -z zone1 shutdown root@sysB:~# zoneadm -z zone1 detach Exported zone zpool: zone1_rpool root@sysB:~# init 0 Step 13) Back on sysA, check the status. Oracle Corporation SunOS 5.11 11.1 September 2012 root@sysA:~# zoneadm list -cv ID NAME STATUS PATH BRAND IP 0 global running / solaris shared - zone1 configured /zones/zone1 solaris excl root@sysA:~# zpool list NAME SIZE ALLOC FREE CAP DEDUP HEALTH ALTROOT rpool 17.6G 11.2G 6.47G 63% 1.00x ONLINE - Step 14) Re-attach the zone back to sysA. root@sysA:~# zoneadm -z zone1 attach Imported zone zpool: zone1_rpool Progress being logged to /var/log/zones/zoneadm.20121022T190441Z.zone1.attach Installing: Using existing zone boot environment Zone BE root dataset: zone1_rpool/rpool/ROOT/solaris Cache: Using /var/pkg/publisher. Updating non-global zone: Linking to image /. Processing linked: 1/1 done Updating non-global zone: Auditing packages. No updates necessary for this image. Updating non-global zone: Zone updated. Result: Attach Succeeded. Log saved in non-global zone as /zones/zone1/root/var/log/zones/zoneadm.20121022T190441Z.zone1.attach root@sysA:~# zpool list NAME SIZE ALLOC FREE CAP DEDUP HEALTH ALTROOT rpool 17.6G 11.2G 6.47G 63% 1.00x ONLINE - zone1_rpool 1.98G 491M 1.51G 24% 1.00x ONLINE - root@sysA:~# zoneadm -z zone1 boot root@sysA:~# zlogin zone1 [Connected to zone 'zone1' pts/2] Oracle Corporation SunOS 5.11 11.1 September 2012 root@zone1:~# zpool list NAME SIZE ALLOC FREE CAP DEDUP HEALTH ALTROOT rpool 1.98G 538M 1.46G 26% 1.00x ONLINE - Step 15) Check for the file created on sysB, earlier. root@zone1:~# ls -l /opt total 1 -rw-r--r-- 1 root root 0 Oct 22 14:47 fileA Next Steps Here is a brief list of some of the fun things you can try next. Add space to the zone by adding a second storage device to the rootzpool. Make sure that you add it to the configurations of both zones! Create a new zone, specifying two disks in the rootzpool when you first configure the zone. When you install that zone, or clone it from another zone, zoneadm uses those two disks to create a mirrored pool. (Three disks will result in a three-way mirror, etc.) Conclusion Hopefully you have seen the ease with which you can now move Solaris Zones from one system to another.

    Read the article

  • rTorrent, too low memory usage !?

    - by Claudiu
    I want to know from more experienced rTorrent users how to tweak the .rtorrent.rc so that rTorrent will cache disk reading and writing (same as uTorrent does). I have set the max_memory_usage = 1GB but this amount is not used. I run 6 rTorrent instances on a Quad Core, 8 GB Ram machine and total used memory reported by htop is only ~500MB. I need to use memory buffers cause disk IO activity is very high.

    Read the article

  • Ubuntu 12.04 boot degraded raid

    - by beacon_bonanza
    I've installed Ubuntu 12.04.1 in a new server and set up the 4 hard drives with 3 RAID 1 devices, the configuration is such that the first two drives have md0 (swap space) and md1 (/) with the third and fourth drives having md2 (/var). I've been testing the operation under a drive failure and found that the system boots fine if I remove disk two but if I remove disk one then the system gets to grub and then just restarts. I'm confused as to why grub appears to be loading properly from disk two but then the boot fails. I've tried to copy the MBR from disk 1 to 2: dd if=/dev/sda of=/dev/sdb bs=512 count=1 but this didn't make a difference. Any ideas how to get it to boot from just the second disk? fdisk -l Disk /dev/sda: 2000.4 GB, 2000398934016 bytes 255 heads, 63 sectors/track, 243201 cylinders, total 3907029168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000ccfa5 Device Boot Start End Blocks Id System /dev/sda1 2048 31250431 15624192 fd Linux RAID autodetect /dev/sda2 * 31250432 3907028991 1937889280 fd Linux RAID autodetect Disk /dev/sdb: 2000.4 GB, 2000398934016 bytes 255 heads, 63 sectors/track, 243201 cylinders, total 3907029168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000ccfa5 Device Boot Start End Blocks Id System /dev/sdb1 2048 31250431 15624192 fd Linux RAID autodetect /dev/sdb2 * 31250432 3907028991 1937889280 fd Linux RAID autodetect Disk /dev/sdd: 2000.4 GB, 2000398934016 bytes 255 heads, 63 sectors/track, 243201 cylinders, total 3907029168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00035b05 Device Boot Start End Blocks Id System /dev/sdd1 2048 3907028991 1953513472 fd Linux RAID autodetect Disk /dev/sdc: 2000.4 GB, 2000398934016 bytes 255 heads, 63 sectors/track, 243201 cylinders, total 3907029168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000c73aa Device Boot Start End Blocks Id System /dev/sdc1 2048 3907028991 1953513472 fd Linux RAID autodetect Disk /dev/md1: 1984.3 GB, 1984264208384 bytes 2 heads, 4 sectors/track, 484439504 cylinders, total 3875516032 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md2: 2000.3 GB, 2000263380992 bytes 2 heads, 4 sectors/track, 488345552 cylinders, total 3906764416 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md0: 16.0 GB, 15990652928 bytes 2 heads, 4 sectors/track, 3903968 cylinders, total 31231744 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000

    Read the article

  • Windows 7 - Deleted boot files!

    - by RadiantHex
    Hi folks, I am (was) using an install of Win7 on the C Disk Partition, I formatted the D Disk Parition, and now Win7 fails to bootup. I suspect the bootup config files were stored within the D Partition, despite the install residing on the C Partition. Any ideas on how I can fix this? :)

    Read the article

  • Windows 7 - Deleted boot files!

    - by RadiantHex
    Hi folks, I am (was) using an install of Win7 on the C Disk Partition, I formatted the D Disk Parition, and now Win7 fails to bootup. I suspect the bootup config files were stored within the D Partition, despite the install residing on the C Partition. This is the error I'm getting: Reboot and Select proper Boot device Any ideas on how I can fix this? :)

    Read the article

  • What do you use for a RAM disk on Windows Server?

    - by thelsdj
    We currently use AR Soft RAM Disk on some Windows 2003 servers for storing short lived temporary files. Looking forward to a move to 64-bit Windows Server 2008 I'm wondering what options there are for a RAM disk since it appears AR Soft RAM Disk was discontinued in 2005. I'm not looking for any physical disk backing, just a pure RAM disk that appears like a normal drive to Windows. Does anyone have any experience with RAM disks on Windows Server 2008, especially for 64-bit?

    Read the article

  • Disk IO causing high load on Xen/CentOS guest

    - by Peter Lindqvist
    I'm having serious issues with a xen based server, this is on the guest partition. It's a paravirtualized CentOS 5.5. The following numbers are taken from top while copying a large file over the network. If i copy the file another time the speed decreases in relation to load average. So the second time it's half the speed of the first time. It needs some time to cool off after this. Load average slowly decreases until it's once again usable. ls / takes about 30 seconds. top - 13:26:44 up 13 days, 21:44, 2 users, load average: 7.03, 5.08, 3.15 Tasks: 134 total, 2 running, 132 sleeping, 0 stopped, 0 zombie Cpu(s): 0.0%us, 0.1%sy, 0.0%ni, 25.3%id, 74.5%wa, 0.0%hi, 0.0%si, 0.1%st Mem: 1048752k total, 1041460k used, 7292k free, 3116k buffers Swap: 2129912k total, 40k used, 2129872k free, 904740k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 1506 root 10 -5 0 0 0 S 0.3 0.0 0:03.94 cifsd 1 root 15 0 2172 644 556 S 0.0 0.1 0:00.08 init Meanwhile the host is ~0.5 load avg and steady over time. ~50% wait Server hardware is dual xeon, 3gb ram, 170gb scsi 320 10k rpm, and shouldn't have any problems with copying files over the network. disk = [ "tap:aio:/vm/dev01.img,xvda,w" ] I also get these in the log INFO: task syslogd:1350 blocked for more than 120 seconds. "echo 0 > /proc/sys/kernel/hung_task_timeout_secs" disables this message. syslogd D 00062E4F 2208 1350 1 1353 1312 (NOTLB) c0ef0ed0 00000286 6e71a411 00062e4f c0ef0f18 00000009 c0f20000 6e738bfd 00062e4f 0001e7ec c0f2010c c181a724 c1abd200 00000000 ffffffff c0ef0ecc c041a180 00000000 c0ef0ed8 c03d6a50 00000000 00000000 c03d6a00 00000000 Call Trace: [<c041a180>] __wake_up+0x2a/0x3d [<ee06a1ea>] log_wait_commit+0x80/0xc7 [jbd] [<c043128b>] autoremove_wake_function+0x0/0x2d [<ee065661>] journal_stop+0x195/0x1ba [jbd] [<c0490a32>] __writeback_single_inode+0x1a3/0x2af [<c04568ea>] do_writepages+0x2b/0x32 [<c045239b>] __filemap_fdatawrite_range+0x66/0x72 [<c04910ce>] sync_inode+0x19/0x24 [<ee09b007>] ext3_sync_file+0xaf/0xc4 [ext3] [<c047426f>] do_fsync+0x41/0x83 [<c04742ce>] __do_fsync+0x1d/0x2b [<c0405413>] syscall_call+0x7/0xb ======================= I have tried disabling irqbalanced as suggested here but it does not seem to make any difference.

    Read the article

  • Do I dare clicking Delete Volume instead of Delete Partition?

    - by Olle
    I have a VMWare machine with one VM. That VM has a virtual disk which in windows is configured with two partitions and then a lot of slack space, as illustrated here: http://piclair.com/q8g5s What I want to do is delete the partition of 639 GB. However, since it's a dynamic disk, the right menu item says "Delete Volume" instead of "Delete Partition" (when I right click the 639GB space). My question is weather I dare to use "Delete Volume". I have read doing stuff like this on a dynamic volume can cause other partitions/volumes to go corrupt.

    Read the article

  • Enabling quota and doing quotacheck on reboot

    - by nixnotwin
    I have setup quota for home directories on ubuntu 10.04 server. I followed these tutorials: 5 Steps to Setup User and Group Disk Quota and Disk Quota This code I used at fstab file: /dev/sda1 /home ext4 defaults,usrjquota=aquota.user,grpjquota=aquota.grp,jqfmt=vfsv0 1 1 I have doubts about whether following steps are necessary: Adding quotaon -a >/dev/null 2>&1 to /etc/rc.local and adding quotacheck -avug to /etc/cron.daily/quotacheck

    Read the article

  • How much does HDD cache matter with Linux softraid?

    - by Jawa
    I'm in a process of renewing/expanding my disk sets, but not quite sure what kind of disks to get, cache-wise. What difference does disk cache amount of 16/32/64MB do, in capacities of, say, 1/1.5/2TB SATA disks? The disks will be used in a webapp server and in a media workstation, with Linux's softraid in raid-1/raid-5 configurations. Note, that as both purposes are purely for a hobby, the pricetag for a dozen of disks is a big issue.

    Read the article

  • Fedora 11 System - Failed Hard Drive Removed, and Boot gets GRUB Hard Disk Error

    - by Mindful
    Greetings, I have a machine with a 120GB ATA drive that has what I thought to be non-essential data on it. I also have a 320GB SATA hard drive with the OS/Application/Files (good data I want to keep). My 120GB ATA is failing I believe, as my computer kept slowing to a halt. However, when I move the drive from BIOS my computer will not start, says "GRUB Hard Disk Error". I know that my Fedora system has an LVM setup. I am looking to just remove the 120GB drive from "the mix", and just have one hard drive. How do I recover ? Thank you. I have access to a Linux Live CD right now and can make any changes. However, it won't boot into my OS - it fails. UPDATE: here's my Grub.Conf # grub.conf generated by anaconda # # Note that you do not have to rerun grub after making changes to this file # NOTICE: You have a /boot partition. This means that # all kernel and initrd paths are relative to /boot/, eg. # root (hd1,0) # kernel /vmlinuz-version ro root=/dev/VolGroup00/LogVol00 # initrd /initrd-version.img #boot=/dev/sda1 default=0 timeout=5 splashimage=(hd1,0)/grub/splash.xpm.gz hiddenmenu title Fedora (2.6.30.10-105.2.23.fc11.i686.PAE) root (hd1,0) kernel /vmlinuz-2.6.30.10-105.2.23.fc11.i686.PAE ro root=/dev/VolGroup00/LogVol00 rhgb quiet initrd /initrd-2.6.30.10-105.2.23.fc11.i686.PAE.img title Fedora (2.6.30.9-102.fc11.i686.PAE) root (hd1,0) kernel /vmlinuz-2.6.30.9-102.fc11.i686.PAE ro root=/dev/VolGroup00/LogVol00 rhgb quiet initrd /initrd-2.6.30.9-102.fc11.i686.PAE.img title Fedora (2.6.27.24-170.2.68.fc10.i686.PAE) root (hd1,0) kernel /vmlinuz-2.6.27.24-170.2.68.fc10.i686.PAE ro root=/dev/VolGroup00/LogVol00 rhgb quiet initrd /initrd-2.6.27.24-170.2.68.fc10.i686.PAE.img title Fedora (2.6.27.24-170.2.68.fc10.i686) root (hd1,0) kernel /vmlinuz-2.6.27.24-170.2.68.fc10.i686 ro root=/dev/VolGroup00/LogVol00 rhgb quiet initrd /initrd-2.6.27.24-170.2.68.fc10.i686.img title Fedora (2.6.27.21-170.2.56.fc10.i686) root (hd1,0) kernel /vmlinuz-2.6.27.21-170.2.56.fc10.i686 ro root=/dev/VolGroup00/LogVol00 rhgb quiet initrd /initrd-2.6.27.21-170.2.56.fc10.i686.img title Fedora (2.6.27.19-170.2.35.fc10.i686) root (hd1,0) kernel /vmlinuz-2.6.27.19-170.2.35.fc10.i686 ro root=/dev/VolGroup00/LogVol00 rhgb quiet initrd /initrd-2.6.27.19-170.2.35.fc10.i686.img title Upgrade to Fedora 10 (Cambridge) kernel /upgrade/vmlinuz preupgrade repo=hd::/var/cache/yum/preupgrade stage2=http://chi-10g-1-mirror.fastsoft.net/pub/linux/fedora/linux/releases/10/Fedora/i386/os/images/install.img ks=hd:UUID=f11769ba-29bc-46de-8c40-a949720a438e:/upgrade/ks.cfg initrd /upgrade/initrd.img title Win rootnoverify (hd0,0) chainloader +1

    Read the article

  • Routing and Remote Access Service won't start after full disk

    - by NKCSS
    The HDD of the server was out of disk space, and after a reboot, RRAS won't start anymore on my 2008 R2 server. Error Details: Log Name: System Source: RemoteAccess Date: 2/5/2012 9:39:52 PM Event ID: 20153 Task Category: None Level: Error Keywords: Classic User: N/A Computer: Windows14111.<snip> Description: The currently configured accounting provider failed to load and initialize successfully. The connection was prevented because of a policy configured on your RAS/VPN server. Specifically, the authentication method used by the server to verify your username and password may not match the authentication method configured in your connection profile. Please contact the Administrator of the RAS server and notify them of this error. Event Xml: <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event"> <System> <Provider Name="RemoteAccess" /> <EventID Qualifiers="0">20153</EventID> <Level>2</Level> <Task>0</Task> <Keywords>0x80000000000000</Keywords> <TimeCreated SystemTime="2012-02-05T20:39:52.000Z" /> <EventRecordID>12148869</EventRecordID> <Channel>System</Channel> <Computer>Windows14111.<snip></Computer> <Security /> </System> <EventData> <Data>The connection was prevented because of a policy configured on your RAS/VPN server. Specifically, the authentication method used by the server to verify your username and password may not match the authentication method configured in your connection profile. Please contact the Administrator of the RAS server and notify them of this error.</Data> <Binary>2C030000</Binary> </EventData> </Event> I think it has something to do with a corrupt config file, but I am unsure of what to do. I Removed the RRAS role, rebooted, and re-added, but it keeps failing with the same error. Thanks in advance. [UPDATE] If i set the accounting provider from 'Windows' to '' the service starts but VPN won't work. Any ideas how this can be repaired?

    Read the article

  • Server with 3 Disk, what's the best HD Configuration?

    - by aleroot
    I Have an HP Server with a quad core Opteron and 3 Disk 250Gb S-ATA Disk, i'm thinking about what's the best configuration of the disk for performance and reliability. There is mainly 2 scenario : -RAID 5 with these 3 HD (on the the array 100GB Partition for OS, Other Space for Data Partition) -RAID 1 + 1 Disk for OS (one single Disk OS Installation, RAID 1 Array for a Data Partition) What's the best configuration ? In the Server Run MySQL and Small Document File server, the OS to be installed is Windows Server 2008 ...

    Read the article

  • Windows 8 disk errors

    - by wrongusername
    So yesterday, I forcibly restarted my Windows 8 PC. VMWare Workstation was having some trouble with the guest Linux Mint OS. It wasn't responding for some time, so I tried suspending it September 28th or perhaps even before. It wouldn't suspend -- I forgot what the window looked like, but all options in the power menu were disabled (i.e. "Shutdown," "Power Off," and options like that were all disabled). I eventually killed the VMWare application through Task Manager, though I was too lazy to hunt down the running virtual machine itself, and decided to kill it by just shutting down my PC entirely. The PC wouldn't shut down for quite some time after the monitor went blank, so I did a cold reset by holding the power button. I then powered it on again and Windows briefly gave me some message like "Search for KERNEL_STACK_INPAGE_ERROR." Windows then started diagnosing some problems and gave me the message, "Repairing disk errors. This might take over an hour to complete." That was yesterday night, and I went to sleep without waiting for it to finish. This morning, it said that the repair failed, and that the log was at C:\windows\system32\LogFiles\srt\srtTrail.txt (as I remember it -- I don't have the exact path I wrote down right now). It gave me some other options to troubleshoot, such as resetting Windows (files and settings still intact, but programs not installed through the app store will be erased). That didn't work (no error message given, I was just told it didn't work). I tried rebooting in safe mode, the same diagnosis process begins, except that this time it doesn't bother with the automatic repairs again. So I tried using the command prompt to try to see if my files are at least still there. I was on the X drive, and I couldn't cd to the C drive. I couldn't find my folder under Users (of course?), and couldn't find the srt folder under LogFiles either. I am not sure what to try next. I have backed up everything, but to the cloud, so if absolutely necessary I can start off with a fresh copy of Windows and restore all my data, though it would be a hassle. Any thoughts on what might be wrong or what I can try? My computer was purchased just this June, so the hard drive should still be pretty new.

    Read the article

  • Is it possible to change the Raid5 chunk size of an existing device?

    - by AlexCombas
    I have an existing raid5 device which I created using mdadm on Linux. When I created the device I set the chunk size to 64 but I would like to test the performance of various sizes but I don't want to have to rebuild my entire system to do so. If it is not possible to do it live then is it possible to do this by booting with a rescue disk? Any advice on the steps how to do this, either live or with a rescue disk, will be greatly appreciated.

    Read the article

  • TFS Disk Structure - and "Add new folder" vs "Add solution"

    - by NealWalters
    Our organization recently got TFS 2008 set up ready for our use. I have a practice TeamProject available to play with. To simplify slightly, we previous organized our code on disk like this: -EC - Main - Database - someScript1.sql - someScript2.sql - Documents - ReleaseNotes_V1.doc - Source - Common - Company.EC.Common.Biztalk.Artifacts [folder] - Company.EC.Common.BizTalk.Components [folder] - Company.EC.Common.Biztalk.Deployment [folder] - Company.EC.BookTransfer.BizTalk.sln - BookTransfer - Company.EC.BookTransfer.BizTalk.Artifacts [folder] - Company.EC.BookTransfer.BizTalk.Components [folder] - Company.EC.BookTransfer.BizTalk.Components.UnitTest [folder] - Company.EC.BookTransfer.BizTalk.Deployment [folder] - Company.EC.BookTransfer.BizTalk.sln I'm trying to decide, do I want to check in the entire c:\EC directory? Or do I want to open each solution and checkin. What are the pros and cons of each? It seems like by doing the "Add Files/Folder" option, I could check in everything at once and it would match the disk structure. It also looks like that if I check in each solution separately, that creates another working folder in my Workspace. I think if I check in by "add files/folder", I will have one workspace and that would be better. But most of the books and samples I see talk about checking in projects and solutions. P.S. I know I need to add more to my disk structure in accordance with the Branch/Merge guidelines, but that is not the question I'm asking here. Thanks, Neal Walters

    Read the article

  • Script to copy files on CD and not on hard disk to a new directory

    - by John22
    I need to copy files from a set of CDs that have a lot of duplicate content, with each other, and with what's already on my hard disk. The file names of identical files are not the same, and are in sub-directories of different names. I want to copy non-duplicate files from the CD into a new directory on the hard disk. I don't care about the sub-directories - I will sort it out later - I just want the unique files. I can't find software to do that - see my post at SuperUser http://superuser.com/questions/129944/software-to-copy-non-duplicate-files-from-cd-dvd Someone at SuperUser suggested I write a script using GNU's "find" and the Win32 version of some checksum tools. I glanced at that, and have not done anything like that before. I'm hoping something exists that I can modify. I found a good program to delete duplicates, Duplicate Cleaner (it compares checksums), but it won't help me here, as I'd have to copy all the CDs to disk, and each is probably about 80% duplicates, and I don't have room to do that - I'd have to cycle through a few at a time copying everything, then turning around and deleting 80% of it, working the hard drive a lot. Thanks for any help.

    Read the article

  • How to load/save C++ class instance (using STL containers) to disk

    - by supert
    I have a C++ class representing a hierarchically organised data tree which is very large (~Gb, basically as large as I can get away with in memory). It uses an STL list to store information at each node plus iterators to other nodes. Each node has only one parent, but 0-10 children. Abstracted, it looks something like: struct node { public: node_list_iterator parent; // iterator to a single parent node double node_data_array[X]; map<int,node_list_iterator> children; // iterators to child nodes }; class strategy { private: list<node> tree; // hierarchically linked list of nodes struct some_other_data; public: void build(); // build the tree void save(); // save the tree from disk void load(); // load the tree from disk void use(); // use the tree }; I would like to implement the load() and save() to disk, and it should be fairly fast, however the obvious problems are: I don't know the size in advance; The data contains iterators, which are volatile; My ignorance of C++ is prodigious. Could anyone suggest a pure C++ solution please?

    Read the article

  • XFS disk becomes unavailable after a while

    - by Guard
    Ubuntu 12.04 (but the same was on 11.10 before upgrading) WD MyBook, 2TB, no RAID (or RAID0, not completely sure, anyway no mirroring, both 1TB disks are in use, mounted as a single device). Formatted to XFS, normally used for big movie files. Connected to Firewire 800. At some point the LED started going up and down as when constantly reading/writing. The device gives access error. When unplugged (cable, then holding the power button for a while, then unplugging the power) and re-connected becomes available. xfs_check with no results. xfs_repair did something, but looks like didn't fix any error. Then after a massive read (checking 1.5GB torrent file for integrity) becomes unavailable again. Any ideas what's wrong? Drives? Cables? Motherboard? OS? UPD: not sure how relevant this is, but here are dmesg output [14380.632816] SGI XFS with ACLs, security attributes, realtime, large block/inode numbers, no debug enabled [14380.633356] SGI XFS Quota Management subsystem [14421.812220] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 [14441.890596] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 [14441.896858] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 [14453.895347] firewire_core: created device fw1: GUID 0090a99500a35518, S400, 9 config ROM retries [14453.904818] scsi6 : SBP-2 IEEE-1394 [14453.905014] scsi7 : SBP-2 IEEE-1394 [14454.139993] firewire_sbp2: fw1.0: logged in to LUN 0000 (0 retries) [14454.158769] scsi 6:0:0:0: Direct-Access WD My Book 1015 PQ: 0 ANSI: 4 [14454.159251] sd 6:0:0:0: Attached scsi generic sg3 type 0 [14454.162391] firewire_sbp2: fw1.1: logged in to LUN 0001 (0 retries) [14454.167453] sd 6:0:0:0: [sdc] 3907017568 512-byte logical blocks: (2.00 TB/1.81 TiB) [14454.178822] sd 6:0:0:0: [sdc] Write Protect is off [14454.178826] sd 6:0:0:0: [sdc] Mode Sense: 10 00 00 00 [14454.186830] scsi 7:0:0:1: Enclosure WD My Book Device 1015 PQ: 0 ANSI: 4 [14454.186995] scsi 7:0:0:1: Attached scsi generic sg4 type 13 [14454.190078] sd 6:0:0:0: [sdc] Cache data unavailable [14454.190087] sd 6:0:0:0: [sdc] Assuming drive cache: write through [14454.202176] sd 6:0:0:0: [sdc] Cache data unavailable [14454.202185] sd 6:0:0:0: [sdc] Assuming drive cache: write through [14454.239940] sdc: [mac] sdc1 sdc2 sdc3 sdc4 [14454.271262] sd 6:0:0:0: [sdc] Cache data unavailable [14454.271270] sd 6:0:0:0: [sdc] Assuming drive cache: write through [14454.271354] sd 6:0:0:0: [sdc] Attached SCSI disk [14454.272149] ses 7:0:0:1: Attached Enclosure device [14606.090024] XFS (sdc3): Mounting Filesystem [14612.048343] XFS (sdc3): Starting recovery (logdev: internal) [14620.697636] XFS (sdc3): Ending recovery (logdev: internal) [14748.120957] e1000e: eth0 NIC Link is Up 100 Mbps Full Duplex, Flow Control: Rx/Tx [14748.120963] e1000e 0000:00:19.0: eth0: 10/100 speed: disabling TSO [14752.568382] uhci_hcd 0000:00:1a.0: PCI INT A disabled [14752.568579] uhci_hcd 0000:00:1a.1: PCI INT B disabled [14752.568738] ehci_hcd 0000:00:1a.7: PCI INT C disabled [14752.568779] ehci_hcd 0000:00:1a.7: PME# enabled [14752.584526] uhci_hcd 0000:00:1d.1: PCI INT B disabled [14752.584689] uhci_hcd 0000:00:1d.2: PCI INT C disabled [14752.680079] ehci_hcd 0000:00:1a.7: BAR 0: set to [mem 0xe4641000-0xe46413ff] (PCI address [0xe4641000-0xe46413ff]) [14752.680104] ehci_hcd 0000:00:1a.7: restoring config space at offset 0xf (was 0x300, writing 0x30b) [14752.680136] ehci_hcd 0000:00:1a.7: restoring config space at offset 0x1 (was 0x2900000, writing 0x2900002) [14752.680170] ehci_hcd 0000:00:1a.7: PME# disabled [14752.680182] ehci_hcd 0000:00:1a.7: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [14752.680190] ehci_hcd 0000:00:1a.7: setting latency timer to 64 [14752.710334] uhci_hcd 0000:00:1a.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [14752.710342] uhci_hcd 0000:00:1a.0: setting latency timer to 64 [14752.749186] uhci_hcd 0000:00:1a.1: PCI INT B -> GSI 17 (level, low) -> IRQ 17 [14752.749194] uhci_hcd 0000:00:1a.1: setting latency timer to 64 [14752.790231] uhci_hcd 0000:00:1d.1: PCI INT B -> GSI 22 (level, low) -> IRQ 22 [14752.790239] uhci_hcd 0000:00:1d.1: setting latency timer to 64 [14752.829170] uhci_hcd 0000:00:1d.2: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [14752.829178] uhci_hcd 0000:00:1d.2: setting latency timer to 64

    Read the article

  • Event on SQL Server 2008 Disk IO and the new Complex Event Processing (StreamInsight) feature in R2

    - by tonyrogerson
    Allan Mitchell and myself are doing a double act, Allan is becoming one of the leading guys in the UK on StreamInsight and will give an introduction to this new exciting technology; on top of that I'll being talking about SQL Server Disk IO - well, "Disk" might not be relevant anymore because I'll be talking about SSD and IOFusion - basically I'll be talking about the underpinnings - making sure you understand and get it right, how to monitor etc... If you've any specific problems or questions just ping me an email [email protected]. To register for the event see: http://sqlserverfaq.com/events/217/SQL-Server-and-Disk-IO-File-GroupsFiles-SSDs-FusionIO-InRAM-DBs-Fragmentation-Tony-Rogerson-Complex-Event-Processing-Allan-Mitchell.aspx 18:15 SQL Server and Disk IOTony Rogerson, SQL Server MVPTony's Blog; Tony on TwitterIn this session Tony will talk about RAID levels, how SQL server writes to and reads from disk, the effect SSD has and will talk about other options for throughput enhancement like Fusion IO. He will look at the effect fragmentation has and how to minimise the impact, he will look at the File structure of a database and talk about what benefits multiple files and file groups bring. We will also touch on Database Mirroring and the effect that has on throughput, how to get a feeling for the throughput you should expect.19:15 Break19:45 Complex Event Processing (CEP)Allan Mitchell, SQL Server MVPhttp://sqlis.com/sqlisStreamInsight is Microsoft’s first foray into the world of Complex Event Processing (CEP) and Event Stream Processing (ESP).  In this session I want to show an introduction to this technology.  I will show how and why it is useful.  I will get us used to some new terminology but best of all I will show just how easy it is to start building your first CEP/ESP application.

    Read the article

< Previous Page | 38 39 40 41 42 43 44 45 46 47 48 49  | Next Page >