Search Results

Search found 12773 results on 511 pages for 'ide controller'.

Page 431/511 | < Previous Page | 427 428 429 430 431 432 433 434 435 436 437 438  | Next Page >

  • configure a Cisco ASA to use MS-CHAP v2 for RADIUS authentication

    - by DrStalker
    Cisco ASA5505 8.2(2) Windows 2003 AD server We want to configure our ASA (10.1.1.1) to authenticate remote VPN users through RADIUS on the Windows AD controller (10.1.1.200) We have the following entry on the ASA: aaa-server SYSCON-RADIUS protocol radius aaa-server SYSCON-RADIUS (inside) host 10.1.1.200 key ***** radius-common-pw ***** When I test a login using the account COMPANY\username I see the users credentials are correct in the security log, but I get the following in the windows system logs: User COMPANY\myusername was denied access. Fully-Qualified-User-Name = company.com/CorpUsers/AU/My Name NAS-IP-Address = 10.1.1.1 NAS-Identifier = <not present> Called-Station-Identifier = <not present> Calling-Station-Identifier = <not present> Client-Friendly-Name = ASA5510 Client-IP-Address = 10.1.1.1 NAS-Port-Type = Virtual NAS-Port = 7 Proxy-Policy-Name = Use Windows authentication for all users Authentication-Provider = Windows Authentication-Server = <undetermined> Policy-Name = VPN Authentication Authentication-Type = PAP EAP-Type = <undetermined> Reason-Code = 66 Reason = The user attempted to use an authentication method that is not enabled on the matching remote access policy. My assumption is that the ASA is using PAP authentication, instead of MS-CHAP v2; the credentials are confirmed, the proper Remote Access Policy is being used, but this policy is set to only allow MS-CHAP2. What do we need to do on the ASA to make it us MS-CHAP v2? In the ADSM GUI The "Microsoft CHAP v2 compatible" tickbox is enabled, but I don't know what this corresponds to in the config.

    Read the article

  • Can't successfully run Sharepoint Foundation 2010 first time configuration

    - by Robert Koritnik
    I'm trying to run the non-GUI version of configuration wizard using power shell because I would like to set config and admin database names. GUI wizard doesn't give you all possible options for configuration. I run this command: New-SPConfigurationDatabase -DatabaseName "Sharepoint2010Config" -DatabaseServer "developer.pleiado.pri" -AdministrationContentDatabaseName "Sharepoint2010Admin" -DatabaseCredentials (Get-Credential) -Passphrase (ConvertTo-SecureString "%h4r3p0int" -AsPlainText -Force) Of course all these are in the same line. I've broken them down into separate lines to make it easier to read. When I run this command I get this error: New-SPConfigurationDatabase : Cannot connect to database master at SQL server a t developer.pleiado.pri. The database might not exist, or the current user does not have permission to connect to it. At line:1 char:28 + New-SPConfigurationDatabase <<<< -DatabaseName "Sharepoint2010Config" -Datab aseServer "developer.pleiado.pri" -AdministrationContentDatabaseName "Sharepoint 2010Admin" -DatabaseCredentials (Get-Credential) -Passphrase (ConvertTo-SecureS tring "%h4r3p0int" -AsPlainText -Force) + CategoryInfo : InvalidData: (Microsoft.Share...urationDatabase: SPCmdletNewSPConfigurationDatabase) [New-SPConfigurationDatabase], SPExcep tion + FullyQualifiedErrorId : Microsoft.SharePoint.PowerShell.SPCmdletNewSPCon figurationDatabase I created two domain accounts: SPF_DATABASE - database account SPF_ADMIN - farm account I'm running powershell console as domain administrator. I've tried to run SQL Management studio as domain admin and created a dummy database and it worked wothout a problem. I'm running: Windows 7 x64 on the machine where Sharepoint Foundation 2010 should be installed and also has preinstalled SQL Server 2008 R2 Windows Server 2008 R2 Server Core is my domain controller I've installed Sharepoint according to MS guides http://msdn.microsoft.com/en-us/library/ee554869%28office.14%29.aspx installing all additional patches that are related to my configuration. Any ideas what should I do to make it work?

    Read the article

  • System State Backups using NTbackup fail with error 0x800423f4 (relating to volume shadow copy)

    - by Paul Zimmerman
    We have a Windows Server 2003 R2 running Service Pack 2. It is a domain controller (Global Catalog) and our main internal DNS server. We run a System State backup of the machine to back up Active Directory information and save the backup to a different server. This server has a single drive (C:), and we do have Shadow Copies enabled for the volume (which are completing successfully). The System State Backup is now failing with the following listed in the backup logs: Volume shadow copy creation: Attempt 1. "Event Log Writer" has reported an error 0x800423f4. This is part of System State. The backup cannot continue. Error returned while creating the volume shadow copy:800423f4 Aborting Backup. The operation did not successfully complete. When doing a vssadmin list writers, we sometimes get the following reported for the Event Log Writer (other times it says that it is in the state of "[1] Stable" with "No error"): Writer name: 'Event Log Writer' Writer Id: {eee8c692-67ed-4250-8d86-390603070d00} Writer Instance Id: {c7194e96-868a-49e5-ba99-89b61977753c} State: [8] Failed Last error: Retryable error We have tried disabling the event log service via the registry, rebooting, deleting the event log files from the drive, then re-enabling the service via the registry and rebooting, but this didn't seem to solve the issue. We also get an error message when in the event viewer when trying to open the log for the "File Replication Service" of "Unable to complete the operation on 'File Replication Service'. The security descriptor structure is invalid." I have searched the error via Google and tried a number of different things, but nothing has seemed to help. Any suggestions on what we might try to get the Event Log Writer to behave would be greatly appreciated!

    Read the article

  • blu-ray archiving in vmware ESXi 4

    - by spacecadet77
    Hi, I need some advice about using blu-ray writer for archiving data on vmware ESXi 4. At office we have IBM System x3400 Tower server with ESXi 4 hipervisor and OpenSuse and CentOS GNU/Linux system as guests. Will blu-ray writer work in this setup, and if it will is there any particular model you can suggest. Best regards IBM System x3400 Tower server specification: 1x Intel Quad-Core Xeon E5410 2.33GHz/ 12MB/ 1333MHz (2x CPU max) Intel 5000P chipset, 2x 1GB PC2-5300 DDR2 667MHz SDRAM ECC Chipkill (32GB max) 2x4GB (2x2GB) PC2-5300 CL5 ECC DDR2 FBDIMM (x3400, x3550, x3650) SAS/SATA Hot-Swap Open Bay (0xHDD std, 4xHDD max, 8xHDD optional) ServeRAID 8K dual channel SAS/SATA controller (RAID 0,1,1E,10,5,6, 256MB, Battery Backup) Graphics ATI® RN50(ES1000) 16MB DDR, CD-RW/DVD Combo no FDD GigaEthernet, Tower with Power Supply 835W (opt Redudant) Slot 1: half-length, PCI-Express x8(x4 electrical) Slot 2: full, PCI-Express x8 Slot 3: full, PCI-Express x8 Slot 4: full, 64-bit 133MHz 3.3v PCI-X Slot 5: full, 64-bit 133MHz 3.3v PCI-X , Slot 6: half-length, 32-bit 33MHz 5.0v PCI ports: 4x USB (Vers 2.0), 2x PS/2, parallel, 2x serial (9-pin), VGA, RJ-45 (ethernet ), RJ-45 (sys mgm) HDD 4 x TB 7200rpm / Serial ATA II 3.0Gb/s / 16MB, RoHS

    Read the article

  • LDAP authentication issue with Kerio Connect

    - by djk
    We have Kerio Connect (mail server) running on a Windows Server 2003 server on a domain. In the webmail client, users are able to change their domain password. This functionality used to work fine until a user tried to change their password a few days ago, when every password they'd try would result in the webmail client claiming their password was "invalid". I spoke to Kerio about this and they claim that this error is returned by the domain controller, which supports my initial investigations. The error that the DC is logging when an attempt is made to change the password is this: "80090308: LdapErr: DSID-0C090334, comment: AcceptSecurityContext error, data 52e, vece" The "data 52e" part indicates that this is an "invalid credentials" error. I don't see how this can be as I've tried (in the Kerio Connect configuration) various accounts that have privileges to modify accounts, including my own as I am a domain admin. I have ran 'dcdiag' (all tests) on the DC and it came back passing every single one of them. I've searched high and low for an answer to this and came up empty. Does anyone have any idea why this may have suddenly started happening? Thanks! Edit: I should mention that the passwords we are changing to do comply with the complexity policy.

    Read the article

  • Server 2008 R2 - Unable to install any printer drivers

    - by toffitomek
    My problem is exactly this same as described here: Server 2008 R2 - Unable to install any printer drivers Options - google groups I have few Windows 2008 R2 (no SP1) servers in remote offices, mostly in Domain Controller, and many of them have problems installing ANY printer drivers. following errors show up in Event Log when adding printer driver under Print and Document Services/Print Management/Print Services/ /Drivers OR trying any other way to install drivers: EventID 215: Installing printer driver - failed, error code 0x57, HRESULT 0x80070057. See the event user data for context information. EventID 215: Installing printer driver Canon iR C2380/2550 PCL6 failed, error code 0x0, HRESULT 0x80070057. See the event user data for context information. EventID 215: Installing printer driver Canon iR C2380/2550 PCL6 failed, error code 0x490, HRESULT 0x80070057. See the event user data for context information. in this particular server case this is problem with Canon iRC 2380i printer with Canon Generic PCL6 Driver, but it seems to apply to any driver and any printer (tried different drivers, different versions, PCL, postscript, etc) I'm using 64 bit drivers that should be working on this platform. Any help will be appreciated.

    Read the article

  • XP machines on Domain not reporting WMI Data in a 2003 Server Environment

    - by Az
    I am running into a very quirky issue and I hope someone out there can help. We use a monitoring program for several networks we oversee that is WMI data dependent for a great deal of it's functionality. The Windows 2000 Professional workstations, as well as the 2003 servers in our network report WMI data fine, the Windows XP professional machines will not let me view them from within the WMI snap in for MMC (they return a Win32: Access Denied) error. I am of course logged in with an account with domain admin privileges on the domain controller when I attempt it. DCOM is enabled in component services, and the remote security option is set to allow as well. If we remove the machine from the domain and rejoin it, some workstations will show up as WMI enabled temporarily and then when I try to access them again later I get the access denied error again out of the blue. Hoping someone out there has had a similar problem or they have advice. I have had this problem with the firewall turned on or off. Thanks for your time! -Az

    Read the article

  • psexec: "Access is Denied"?

    - by Electrons_Ahoy
    Inspired by my previous question here, I've been experimenting with PSExec. The goal is to trip off some fairly simple scripts / programs on one WindowsXP machine from another, and as PowerShell 2 doesn't yet do remoting on XP, PSexec seems like it'll solve my problems nicely. However, I can't get anything but the "Access is Denied" error. Here's what I've tried so far: I've got a pair of WindowsXP MCE machines, networked together in a workgroup without a server or domain controller. I've turned off "simple file sharing" on both machines. Under the security policy, Network Access: Sharing and Security model for local accounts is set to Classic, not Guest for both machines. There is an Administrative user for each computer that I know the passwords to. :) With all that, a command like "> psexec \\otherComputer -u adminUser cmd" prompts for the password (like it should) and then exits with: Couldn't access otherComputer: Access is denied. So, at this point I turn to the community. What step am I missing here?

    Read the article

  • New Dell PE R710 - Storage Question

    - by rihatum
    Hi All, Dell PE R710, received from Dell in the following state : Windows Disk 0 1800GB ( Volume C & D ) Windows Disk 1 526 GB (Volume E ) Perc6i Integrated Raid Controller 6 x 500GB Nearline SAS 7200RPM HDDs Raid 5 Configuration with two Virtual Disks I have installed Dell open Manage and it shows the following : Virtual Disk 0 - State : Background Initialization ( 7% ) Virtual Disk 1 - State : Background Initialization ( 25% ) Now when I click on Virtual Disk 0 it shows me all 6 Disks and the same happens when I click on Virtual Disk 1 it displays all 6 disks. But when I click on Storage Perc6i Connector 0 I get 4 Physical disks with the following numbers : Physical Disk 0:0:0 Physical Disk 0:0:1 Physical Disk 0:0:2 Physical Disk 0:0:3 When I click on Storage Perc6i Connector 1 I get 2 Physical Disks Listed in the following way : Physical Disk 1:0:4 Physical Disk 1:0:5 I am a little confused in this description, does this 1:0:4 interprets to Controller1, Disk4. Does this integrated raid card have two controllers coming out of it ? Also, When I first switched on the machine, the boot partition was showing 1GB Available out of 40GB, now its showing 38GB available out of 40GB. Is this because the Virtual Disks are still Initializing ? Any recommendations or suggestions ? Also, this server have 6 x 500GB NearLine SAS Hard drives, what would be a good raid config ? We are planning to use it for Hyper-V with quite a few (7 or 8) virtual servers, your suggestions would be helpful. Also, while the virtual disks are in a initialization state, can I destroy and re-create the raid configuration ? I would have to do it at the BIOS CTRL-M ? Thanks and Regards

    Read the article

  • USB To Serial under OpenSuse 11.3

    - by Lars
    I have a LogiLink USB-To-Serial adapter. This has the PL2303 chip inside. When I insert the device: [26064.927083] usb 7-1: new full speed USB device using uhci_hcd and address 9 [26065.076090] usb 7-1: New USB device found, idVendor=067b, idProduct=2303 [26065.076099] usb 7-1: New USB device strings: Mfr=1, Product=2, SerialNumber=0 [26065.076105] usb 7-1: Product: USB-Serial Controller [26065.076110] usb 7-1: Manufacturer: Prolific Technology Inc. [26065.079181] pl2303 7-1:1.0: pl2303 converter detected [26065.091296] usb 7-1: pl2303 converter now attached to ttyUSB0 So the device is recognized and the converter is attached to ttyUSB0. When I do screen /dev/ttyUSB0 9600 I get the error: bash: /dev/ttyUSB0: Permission denied So I went looking in the file permissions. ls -l from the /dev folder reports: crw-rw---- 1 root dialout 188, 0 2011-04-26 15:47 ttyUSB0 I added my user lars to the dialout group. When I use the commands groups under lars it shows that I'm in the group. Though I still recieve the permissions denied error, as lars, and as root. I'm trying to connect to a console cable to configure some Cisco switches. My OS is OpenSuse 11.3 x86_64 with kernel version 2.6.34.7-0.7-desktop.

    Read the article

  • How to repair multiple KDC an Netlogon errors

    - by Keith Sirmons
    Howdy, I have several erros in the system event log of my single Windows 2003 SP2 domain controller. Multiple member computers on the domain are listed in these errors. I am seeing two similar errors for each computer one second apart in the event log. Event ID 7 Source KDC The Security Account Manager failed a KDC request in an unexpected way. The error is in the data field. The account name was [email protected] and lookup type 0x8. followed by Event ID 7 Source KDC The Security Account Manager failed a KDC request in an unexpected way. The error is in the data field. The account name was MEMBERNAME$ and lookup type 0x8. The Lookup Types are also different, I have 0x8, 0x28, 0x0, 0x20. I am also receiving other authentication errors in the same time frame as all of the KDC errors Event ID 5722 Source NETLOGON The session setup from the computer MEMBERNAME failed to authenticate. The name(s) of the account(s) referenced in the security database is MEMBERNAME$. The following error occurred: Access is denied. I have run dcdiag /v to see if there was something wrong with Active Directory, but all tests passed. I also ran netdiag /v and it appers all of those tests ran. Any ideas on where to start for this issue? Thank you, Keith

    Read the article

  • Windows Server 2008 Services won't start after patch

    - by Antitribu
    After installing the run of the mill patches today on a Windows Server 2008 (Running as an AD controller and Exchange 2007 Server) the machine came back up with "configuring updates stage 3 of 3 0% complete". The machine had been kept reasonably up to date so this likely was caused by a very recent patch. At the leaste the following patches were installed: KB973037 KB969947 KB973565 Restarting the server into safe mode and then subsequently rebooting (with no changes made) allowed the computer to restart and I can now log in normally. However none of the critical services start; including but not limited to Exchange, DNS and Terminal Services (Obviously if DNS doesn't start other things will break). I am unable to run Internet Explorer but Chrome will work. There are no meaningful errors in the event logs as to why services won't start. Under KDC I have The Key Distribution Center (KDC) cannot find a suitable certificate to use for smart card logons, or the KDC certificate could not be verified. Smart card logon may not function correctly if this problem is not resolved. To correct this problem, either verify the existing KDC certificate using certutil.exe or enroll for a new KDC certificate. This is going to be an evil one to debug and I'm kinda hoping someone has encountered it and knows the answer off hand. Thanks all.

    Read the article

  • Proliant RAID 1 Rebuild Questions

    - by Nicholas
    I have a HP Proliant ML350 G5 server that experienced a power supply failure overnight. The power supply was replaced but unfortunately it got restarted with only 1 disk in the RAID 1 set plugged in. (The raid controller is the build in E200i). The raid BIOS then said on start-up that it had entered Interim Recovery Mode. However I would have expected it to still start up with only the 1 drive. The bios however says that it cannot find a C: drive and enters a reboot loop polling the other boot devices. First question is, is this normal behaviour not to start up on 1 disk? The second drive was then plugged in (all drives are ok) and the raid bios started an automatic rebuild on that disk. This appears to be a background process as there is no progress shown. However based on the light flashing it looks like it is working. My second question is how long will this rebuild take? (36GB 15K SAS drive). I cannot see any error messages and it looks like it is rebuilding the drive ok, but the computer still will not start-up. It still says during the boot up process that the C: drive is not found. If I wait for the rebuild to finish, is it likely to fix itself and find the C: drive? Or is there some other problem here?

    Read the article

  • Dell Poweredge 2600 RAID Transfer How-to

    - by DCookie
    Help, please! Hardware: Dell Poweredge 2600 PERC 4 SCSI Drives, 1 standalone 3 in a RAID 5 configuration OS: Windows 2000 Server In other words, a fairly old system. Anyway, we are in the process of taking over support for this site. The current tech wants out and is fading from view fast, so we need to solve this problem: The standalone disk (where the OS was) failed. We've replaced the disk, installed the OS, but need to know exactly how to proceed from here. I've never worked with a RAID system before, so I don't want to touch anything without knowing what I'm doing. We are not certain if the site will want us to attempt to recover the array or wait for the old tech to become available. We have replaced the server with a temporary box, and recovered MOST of the data from an online backup service. However, the other tech failed to backup a part of the data and the only copy of it is on this RAID array. Hence, our caution. We have poked minimally around in the boot-up PERC config utility, and it seems to me that that's where we'll need to be to reclaim the array. Another possibility is that there is some Dell software for the RAID controller we need to acquire. Can anyone provide clues as to how to proceed from here? Any help GREATLY appreciated.

    Read the article

  • Debian and Multipath IO problem

    - by tearman
    Basically the situation is, I have a box running Debian, the box internally has an Intel SCSI RAID controller which is controlling 2 hard drives in RAID1 mode which is where the OS is installed. Further, I have a QLogic fiber channel adapter that connects the unit to a Fiber Channel SAN. My process of installation is I'll install Debian to the local drives, and leave the QLogic firmware out of it for the time being. Then once I get the unit online, I'll install the firmware drivers. This flops my internal drives from /dev/sda to /dev/sdc, which is a bit annoying, but recoverable. Probably should address these by UUID anyways. Once I get back online, I have to install multipath-tools (the framework is a multipath framework). However, once I reboot the machine again, it fails on boot after discovering multipath targets, saying my local drives are busy and cannot be mounted to /root. Any help in what may be the problem here? Or at least how to disable multipath until after the unit boots and then ignores the internal drives?

    Read the article

  • How can I make my PCI-E graphics card visible to Ubuntu when the motherboard has integrated graphics

    - by Norman Ramsey
    I have a Gigabyte GA-MA74GM-S2 motherboard with integrated graphics that shows up on lspci as an ATI Radeon 2100. I also bought a PCI-Express Nvidia graphics card so I could use the VDPAU feature on Linux (plays H.264 in hardware). The BIOS has three settings about which display to initialize first: Integrated graphics PCI graphics PCI-Express graphics (PEG) I set the BIOS on PEG, but I cannot get anything, not even a splash screen or POST messages, to emerge from the PCI-Express graphics card. (I'm using a DVI connector; the card also has an HDMI output.) I cannot get the kernel lspci to see the graphics card; the only VGA controller it acknowledges is the integrated one. Running dmidecode acknowledges the existence of an x16 PCI Express slot, and it says Current usage: Unknown There is an additional BIOS setting called "Internal Graphics Mode" which is normally set to "Auto" which means it is supposed to prefer a PCI Express VGA card. I set it to "Disabled" which now means I'm getting no output at all. I will soon be learning how to do a BIOS reset! Other information: The PCI-E card is a MSI N210-MD512H GeForce 210. This is a fanless card. Although there are no fans to see turning, the heat sink on the PCI-E card is definitely getting hot, so the card is getting some sort of power. It gets all its power from the PCI-E slot; there is no external power connector. The BIOS is an AMI Award BIOS. My question: how can I make the PCI Express graphics card visible to Ubuntu?

    Read the article

  • NGINX MIME TYPE

    - by justanotherprogrammer
    I have my nginx conf file so that when ever a mobile device visits my site the url gets rewritten to m.mysite.com I did it by adding the following set $mobile_rewrite do_not_perform; if ($http_user_agent ~* "android.+mobile|avantgo|bada\/|blackberry|blazer|compal|elaine|fennec|hiptop|iemobile|ip(hone|od)|iris|kindle|lge |maemo|midp|mmp|netfront|opera m(ob|in)i|palm( os)?|phone|p(ixi|re)\/|plucker|pocket|psp|symbian|treo|up\.(browser|link)|vodafone|wap|windows (ce|phone)|xda|xiino") { set $mobile_rewrite perform; } if ($http_user_agent ~* "^(1207|6310|6590|3gso|4thp|50[1-6]i|770s|802s|a wa|abac|ac(er|oo|s\-)|ai(ko|rn)|al(av|ca|co)|amoi|an(ex|ny|yw)|aptu|ar(ch|go)|as(te|us)|attw|au(di|\-m|r |s )|avan|be(ck|ll|nq)|bi(lb|rd)|bl(ac|az)|br(e|v)w|bumb|bw\-(n|u)|c55\/|capi|ccwa|cdm\-|cell|chtm|cldc|cmd\-|co(mp|nd)|craw|da(it|ll|ng)|dbte|dc\-s|devi|dica|dmob|do(c|p)o|ds(12|\-d)|el(49|ai)|em(l2|ul)|er(ic|k0)|esl8|ez([4-7]0|os|wa|ze)|fetc|fly(\-|_)|g1 u|g560|gene|gf\-5|g\-mo|go(\.w|od)|gr(ad|un)|haie|hcit|hd\-(m|p|t)|hei\-|hi(pt|ta)|hp( i|ip)|hs\-c|ht(c(\-| |_|a|g|p|s|t)|tp)|hu(aw|tc)|i\-(20|go|ma)|i230|iac( |\-|\/)|ibro|idea|ig01|ikom|im1k|inno|ipaq|iris|ja(t|v)a|jbro|jemu|jigs|kddi|keji|kgt( |\/)|klon|kpt |kwc\-|kyo(c|k)|le(no|xi)|lg( g|\/(k|l|u)|50|54|e\-|e\/|\-[a-w])|libw|lynx|m1\-w|m3ga|m50\/|ma(te|ui|xo)|mc(01|21|ca)|m\-cr|me(di|rc|ri)|mi(o8|oa|ts)|mmef|mo(01|02|bi|de|do|t(\-| |o|v)|zz)|mt(50|p1|v )|mwbp|mywa|n10[0-2]|n20[2-3]|n30(0|2)|n50(0|2|5)|n7(0(0|1)|10)|ne((c|m)\-|on|tf|wf|wg|wt)|nok(6|i)|nzph|o2im|op(ti|wv)|oran|owg1|p800|pan(a|d|t)|pdxg|pg(13|\-([1-8]|c))|phil|pire|pl(ay|uc)|pn\-2|po(ck|rt|se)|prox|psio|pt\-g|qa\-a|qc(07|12|21|32|60|\-[2-7]|i\-)|qtek|r380|r600|raks|rim9|ro(ve|zo)|s55\/|sa(ge|ma|mm|ms|ny|va)|sc(01|h\-|oo|p\-)|sdk\/|se(c(\-|0|1)|47|mc|nd|ri)|sgh\-|shar|sie(\-|m)|sk\-0|sl(45|id)|sm(al|ar|b3|it|t5)|so(ft|ny)|sp(01|h\-|v\-|v )|sy(01|mb)|t2(18|50)|t6(00|10|18)|ta(gt|lk)|tcl\-|tdg\-|tel(i|m)|tim\-|t\-mo|to(pl|sh)|ts(70|m\-|m3|m5)|tx\-9|up(\.b|g1|si)|utst|v400|v750|veri|vi(rg|te)|vk(40|5[0-3]|\-v)|vm40|voda|vulc|vx(52|53|60|61|70|80|81|83|85|98)|w3c(\-| )|webc|whit|wi(g |nc|nw)|wmlb|wonu|x700|xda(\-|2|g)|yas\-|your|zeto|zte\-)") { set $mobile_rewrite perform; } if ($mobile_rewrite = perform) { rewrite ^ http://m.mywebsite.com redirect; break; } I got it from http://detectmobilebrowsers.com/ IT WORKS.But none of my images/js/css files load only the HTML. And I know its the chunk of code I mentioned above because when I remove it and visit m.mywebsite.com from my mobile device everything loads up.So this bit of code does SOMETHING to my css/img/js MIME TYPES. I found this out through the the console error messages from safari with the user agent set to iphone. text.cssResource interpreted as stylesheet but transferred with MIME type text/html. 960_16_col.cssResource interpreted as stylesheet but transferred with MIME type text/html. design.cssResource interpreted as stylesheet but transferred with MIME type text/html. navigation_menu.cssResource interpreted as stylesheet but transferred with MIME type text/html. reset.cssResource interpreted as stylesheet but transferred with MIME type text/html. slide_down_panel.cssResource interpreted as stylesheet but transferred with MIME type text/html. myrealtorpage_view.cssResource interpreted as stylesheet but transferred with MIME type text/html. head.jsResource interpreted as script but transferred with MIME type text/html. head.js:1SyntaxError: Parse error isaac:208ReferenceError: Can't find variable: head mrp_home_icon.pngResource interpreted as image but transferred with MIME type text/html. M_1_L_289_I_499_default_thumb.jpgResource interpreted as image but transferred with MIME type text/html. M_1_L_290_I_500_default_thumb.jpgResource interpreted as image but transferred with MIME type text/html. M_1_default.jpgResource interpreted as image but transferred with MIME type text/html. default_listing_image.pngResource interpreted as image but transferred with MIME type text/html. here is my whole nginx conf file just incase... worker_processes 1; events { worker_connections 1024; } http { include mime.types; include /etc/nginx/conf/fastcgi.conf; default_type application/octet-stream; sendfile on; keepalive_timeout 65; #server1 server { listen 80; server_name mywebsite.com www.mywebsite.com ; index index.html index.htm index.php; root /srv/http/mywebsite.com/public; access_log /srv/http/mywebsite.com/logs/access.log; error_log /srv/http/mywebsite.com/logs/error.log; #---------------- For CodeIgniter ----------------# # canonicalize codeigniter url end points # if your default controller is something other than "welcome" you should change the following if ($request_uri ~* ^(/main(/index)?|/index(.php)?)/?$) { rewrite ^(.*)$ / permanent; } # removes trailing "index" from all controllers if ($request_uri ~* index/?$) { rewrite ^/(.*)/index/?$ /$1 permanent; } # removes trailing slashes (prevents SEO duplicate content issues) if (!-d $request_filename) { rewrite ^/(.+)/$ /$1 permanent; } # unless the request is for a valid file (image, js, css, etc.), send to bootstrap if (!-e $request_filename) { rewrite ^/(.*)$ /index.php?/$1 last; break; } #---------------------------------------------------# #--------------- For Mobile Devices ----------------# set $mobile_rewrite do_not_perform; if ($http_user_agent ~* "android.+mobile|avantgo|bada\/|blackberry|blazer|compal|elaine|fennec|hiptop|iemobile|ip(hone|od)|iris|kindle|lge |maemo|midp|mmp|netfront|opera m(ob|in)i|palm( os)?|phone|p(ixi|re)\/|plucker|pocket|psp|symbian|treo|up\.(browser|link)|vodafone|wap|windows (ce|phone)|xda|xiino") { set $mobile_rewrite perform; } if ($http_user_agent ~* "^(1207|6310|6590|3gso|4thp|50[1-6]i|770s|802s|a wa|abac|ac(er|oo|s\-)|ai(ko|rn)|al(av|ca|co)|amoi|an(ex|ny|yw)|aptu|ar(ch|go)|as(te|us)|attw|au(di|\-m|r |s )|avan|be(ck|ll|nq)|bi(lb|rd)|bl(ac|az)|br(e|v)w|bumb|bw\-(n|u)|c55\/|capi|ccwa|cdm\-|cell|chtm|cldc|cmd\-|co(mp|nd)|craw|da(it|ll|ng)|dbte|dc\-s|devi|dica|dmob|do(c|p)o|ds(12|\-d)|el(49|ai)|em(l2|ul)|er(ic|k0)|esl8|ez([4-7]0|os|wa|ze)|fetc|fly(\-|_)|g1 u|g560|gene|gf\-5|g\-mo|go(\.w|od)|gr(ad|un)|haie|hcit|hd\-(m|p|t)|hei\-|hi(pt|ta)|hp( i|ip)|hs\-c|ht(c(\-| |_|a|g|p|s|t)|tp)|hu(aw|tc)|i\-(20|go|ma)|i230|iac( |\-|\/)|ibro|idea|ig01|ikom|im1k|inno|ipaq|iris|ja(t|v)a|jbro|jemu|jigs|kddi|keji|kgt( |\/)|klon|kpt |kwc\-|kyo(c|k)|le(no|xi)|lg( g|\/(k|l|u)|50|54|e\-|e\/|\-[a-w])|libw|lynx|m1\-w|m3ga|m50\/|ma(te|ui|xo)|mc(01|21|ca)|m\-cr|me(di|rc|ri)|mi(o8|oa|ts)|mmef|mo(01|02|bi|de|do|t(\-| |o|v)|zz)|mt(50|p1|v )|mwbp|mywa|n10[0-2]|n20[2-3]|n30(0|2)|n50(0|2|5)|n7(0(0|1)|10)|ne((c|m)\-|on|tf|wf|wg|wt)|nok(6|i)|nzph|o2im|op(ti|wv)|oran|owg1|p800|pan(a|d|t)|pdxg|pg(13|\-([1-8]|c))|phil|pire|pl(ay|uc)|pn\-2|po(ck|rt|se)|prox|psio|pt\-g|qa\-a|qc(07|12|21|32|60|\-[2-7]|i\-)|qtek|r380|r600|raks|rim9|ro(ve|zo)|s55\/|sa(ge|ma|mm|ms|ny|va)|sc(01|h\-|oo|p\-)|sdk\/|se(c(\-|0|1)|47|mc|nd|ri)|sgh\-|shar|sie(\-|m)|sk\-0|sl(45|id)|sm(al|ar|b3|it|t5)|so(ft|ny)|sp(01|h\-|v\-|v )|sy(01|mb)|t2(18|50)|t6(00|10|18)|ta(gt|lk)|tcl\-|tdg\-|tel(i|m)|tim\-|t\-mo|to(pl|sh)|ts(70|m\-|m3|m5)|tx\-9|up(\.b|g1|si)|utst|v400|v750|veri|vi(rg|te)|vk(40|5[0-3]|\-v)|vm40|voda|vulc|vx(52|53|60|61|70|80|81|83|85|98)|w3c(\-| )|webc|whit|wi(g |nc|nw)|wmlb|wonu|x700|xda(\-|2|g)|yas\-|your|zeto|zte\-)") { set $mobile_rewrite perform; } if ($mobile_rewrite = perform) { rewrite ^ http://m.mywebsite.com redirect; #rewrite ^(.*)$ $scheme://mywebsite.com/mobile/$1; #return 301 http://m.mywebsite.com; #break; } #---------------------------------------------------# location / { index index.html index.htm index.php; } error_page 500 502 503 504 /50x.html; location = /50x.html { root html; } location ~ \.php$ { try_files $uri =404; fastcgi_pass 127.0.0.1:9000; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; fastcgi_param PATH_INFO $fastcgi_script_name; include /etc/nginx/conf/fastcgi_params; } }#sever1 #server 2 server { listen 80; server_name m.mywebsite.com; index index.html index.htm index.php; root /srv/http/mywebsite.com/public; access_log /srv/http/mywebsite.com/logs/access.log; error_log /srv/http/mywebsite.com/logs/error.log; #---------------- For CodeIgniter ----------------# # canonicalize codeigniter url end points # if your default controller is something other than "welcome" you should change the following if ($request_uri ~* ^(/main(/index)?|/index(.php)?)/?$) { rewrite ^(.*)$ / permanent; } # removes trailing "index" from all controllers if ($request_uri ~* index/?$) { rewrite ^/(.*)/index/?$ /$1 permanent; } # removes trailing slashes (prevents SEO duplicate content issues) if (!-d $request_filename) { rewrite ^/(.+)/$ /$1 permanent; } # unless the request is for a valid file (image, js, css, etc.), send to bootstrap if (!-e $request_filename) { rewrite ^/(.*)$ /index.php?/$1 last; break; } #---------------------------------------------------# location / { index index.html index.htm index.php; } error_page 500 502 503 504 /50x.html; location = /50x.html { root html; } location ~ \.php$ { try_files $uri =404; fastcgi_pass 127.0.0.1:9000; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; fastcgi_param PATH_INFO $fastcgi_script_name; include /etc/nginx/conf/fastcgi_params; } }#sever2 }#http I could just detect the mobile browsers with php or javascript but i need to make the detection at the server level so that i can use the 'm' in m.mywebsite.com as a flag in my controllers (codeigniter) to serve up the right view. I hope someone can help me! Thank you!

    Read the article

  • Recommended motherboard with hardware raid for Linux

    - by luison
    Hi. We want to setup an internal office server for testing jobs (LAMP), email and samba. Only about 5-10 users. We are also considering starting to virtualize, initially by a base Ubuntu Server with Xen or VMWare Open Source server. Our current system runs with a Linux Raid which has worked great but it's always been complicated to recover the boot sector when one the drives fail and therefore I would prefer using now a hardware raid instead, but ideally with some kind of software monitoring. For this reason and considering we don't want to spend a fortune a I would appreciate any comments on the following options. Motherboard with RAID with linux support... which could you recommend. Motherboard + Hardware Raid card... Adaptec does not seem to have great Linux suppport. 3Ware seems to have a tc soft controller which we've used on a hosting company, but hard to find here in Spain. HP Proliant type basic server, which? Dell Small Servers... any good for Linux? Thanks in advance for any feedback.

    Read the article

  • Can VMWare Server 2.0 be useful in Production for easing backups?

    - by Keith Sirmons
    Howdy, Let's run this idea by the group here. I am thinking about using VMWare Server in production to host a 2008 Domain Controller with DHCP and DNS, a 2008 member server with WSUS, some virus software, and other "management" utilities a second 2008 member server with SQL, IIS, and File Shares for a medium business of 50-100 desktops. The reason I am leaning toward Server vs ESXi is for backup purposes. Using ESXi, if I want to backup the VM's, I would need a second server in the office with enough storage availability to hold a copy of the vmdks. I am wondering if putting this virtual environment on top of a basic 2008 server install will allow for easier backups to both tape and/or to offsite storage using JungleDisk. Can a snapshot be triggered easily via a scheduled job? I know this doesn't necessarily handle file level restores, but I want to make sure in a DR situation, we can restore production servers quickly. Does this concept hold water? Would a very minimum install of the 2008 Host remove too many resources from the actual production machines? This would be a new Dell 410 server with 12 GB ram and (6) 600 GB 15K in a RAID 6, Dual Intel Xeon 2.26GHz procs.

    Read the article

  • Windows 7 install detects SSD but doesn't list it to install to

    - by Mohamed Meligy
    I'm having quite a weird problem when trying to install Windows 7 SP1 on a new Corsair Force Series 3 SSD to replace a failing HDD in my wife's laptop. When I boot to Windows install, it shows that I have no disks to install to, and tells me to find it a driver to any custom disks I may have. When I go to repair option on the first install window, and then open command prompt Window, I can see the disk using diskpart, and can partition it and format partitions, and then later access them from command prompt and copy files to them. After creating partitions, clicking the "browse" button in Windows install screen that shows no disks available to install Windows to, does show the partitions created by diskpart! So, it does detect the disk and partitions, but refuses to list them as options to install to. People on the Interwebs seem to suggest that just running diskpart "clean" solved the issue for most people, just creating an "active" "primary" partition is al most tutorials suggest. Both got me only as far as described above. The BIOS doesn't have RAID option, changing between "ATA" and "AHCI" (the only available options) didn't make any difference. Might be worth mentioning that this is on a laptop that has Sata III controller for main drive (which I connected the Sata3 SSD to), and Sata II for DVD (which I used for Windows install media). That's what googling brings at least (DELL XPS 15 L502). Any ideas? . Update: The SSD is 460 GB. I tried setting it all as one partition and creating 70-90 GB partition as well (NTFS). More importantly, Windows doesn't list the partition as one it cannot install to (which it does with disks in general when they are small for example). What happens here is different. It doesn't list anything at all. It shows empty list of drives.

    Read the article

  • Bad Blocks Exist in Virtual Device PERC H700 Integrated

    - by neoX
    I have a DELL server with PERC H700 Integrated controller. I've made RAID5 with 12 harddrives and the virtual device is in Optimal state, but I receive such errors under linux: sd 0:2:0:0: [sda] Unhandled error code sd 0:2:0:0: [sda] Result: hostbyte=0x07 driverbyte=0x00 sd 0:2:0:0: [sda] CDB: cdb[0]=0x88: 88 00 00 00 00 07 22 50 bd 98 00 00 00 08 00 00 end_request: I/O error, dev sda, sector 30640487832 sd 0:2:0:0: [sda] Unhandled error code sd 0:2:0:0: [sda] Result: hostbyte=0x07 driverbyte=0x00 sd 0:2:0:0: [sda] CDB: cdb[0]=0x88: 88 00 00 00 00 07 22 50 bd 98 00 00 00 08 00 00 end_request: I/O error, dev sda, sector 30640487832 sd 0:2:0:0: [sda] Unhandled error code sd 0:2:0:0: [sda] Result: hostbyte=0x07 driverbyte=0x00 sd 0:2:0:0: [sda] CDB: cdb[0]=0x88: 88 00 00 00 00 07 22 50 bc e0 00 00 01 00 00 00 end_request: I/O error, dev sda, sector 30640487648 But all disk are in Firmware state: Online, Spun Up. Also there is not a single ATA read or write error in any disk in the raid (I check them with smartctl -a -d sat+megaraid,N -H /dev/sda). The only strange thing is in the output in megacli: megacli -LDInfo -L0 -a0 ... Bad Blocks Exist: Yes How could there be bad blocks in a Virtual Drive, which is in optimal state and no disk is broken or even with a single error? I tried "Consistency Check", but it finished successfully and the errors are still in dmesg. Could Someone help me to figure it out what is wrong with my raid?

    Read the article

  • How to diagnose disk errors when disk appears to be ok?

    - by Kylotan
    I have a six-month-old 1TB Seagate drive formatted into 2 NTFS partitions, and the disk appeared to be failing with Windows dropping down from UDMA to PIO mode, reporting Delayed Write Errors, and hanging Explorer when browsing directories. My initial suspicion was that the disk was dying. However, on further examination it appears that Ubuntu, which doesn't write to the volume frequently like Windows does, was able to read the disk properly and retrieve all the data intact, saving me from having to use an older backup. Finally, running the Seatools DOS diagnostic reported that the disk has no problems, ie. SMART errors and no bad sectors, apparently. This, in combination with the relative youth of the disk, suggests that something else is broken. The cable? The PSU? The integrated disk controller? But what would be a good way to diagnose the problem without risking damaging the data? I intend to extract the disk and try it in an external eSATA enclosure and see if the write errors cease, but in the event of the disk appearing to be fine, I would like to be able to confirm what part of the hardware is actually broken here in order to know just what needs replacing. Are there any good ways to go about this?

    Read the article

  • How to diagnose disk errors when disk appears to be ok?

    - by Kylotan
    I have a six-month-old 1TB Seagate drive formatted into 2 NTFS partitions, and the disk appeared to be failing with Windows dropping down from UDMA to PIO mode, reporting Delayed Write Errors, and hanging Explorer when browsing directories. My initial suspicion was that the disk was dying. However, on further examination it appears that Ubuntu, which doesn't write to the volume frequently like Windows does, was able to read the disk properly and retrieve all the data intact, saving me from having to use an older backup. Finally, running the Seatools DOS diagnostic reported that the disk has no problems, ie. SMART errors and no bad sectors, apparently. This, in combination with the relative youth of the disk, suggests that something else is broken. The cable? The PSU? The integrated disk controller? But what would be a good way to diagnose the problem without risking damaging the data? I intend to extract the disk and try it in an external eSATA enclosure and see if the write errors cease, but in the event of the disk appearing to be fine, I would like to be able to confirm what part of the hardware is actually broken here in order to know just what needs replacing. Are there any good ways to go about this?

    Read the article

  • Cannot connect to local network shares when connected to VPN. Error: "the user name could not be found"

    - by Nick G
    I keep finding that on our small company LAN (7 users, 3 servers) that some servers keep becoming "not accessible" for the purposes of file sharing. They display the message "\SERVER is not accessible. You might not have permission to use this network resource. The user name could not be found". But I don't know why "the user name could not be found" as all the machines are on the same domain and the PDC and BDC seem to be behaving OK. EDIT: VPN seems to be the cause: It turns out I can see the server if I use the IP address (\\1.2.3.4\ etc) or the FQ active directory name (eg \server.domainname.local) but not if I use the server name on its own or a mapped network drive originally created from the "short" name. Oddly though, my machine has no issue resolving the server's DNS name as I can ping the machine name OK and it immediately comes back with the IP, however nslookup seems to fail. It seems to be a problem with how Windows looks up machine names when connected to VPNs. When I'm connected to a VPN, windows seems to use the DNS assocated with the VPN and not the one on the domain controller. This behavior to me, seems incorrect as surely that would mean connecting to any VPN would break any ability to lookup local machine names for servers and printers etc. So I guess the real question now is, how can I make my machine still search the local Active Directory DNS (the PDC) even when connected to a VPN? More info in my comments below.

    Read the article

  • Server 2003, XP Clients, DNS issues

    - by ron
    Hello, Im having DNS issues on my network. My DC is my DNS server 10.76.4.11 and recently I configured a forwarder to 10.4.36.10. My workstations are not working because they cannot resolve the domain controller name because of DNS. an ipconfig /all reveals that they know the IP of the DNS server is 10.76.4.11, but if I nslookup 10.76.4.11 it forwards the request to 10.4.36.10 and goes nowhere. I have since removed the forwarder, but still any nslookup requests on workstations are going to 10.4.36.10. If I nslookup 10.76.4.11 on the server it can resolve its name, but for some reason when it receives the same request from workstations it doesnt know what to do. All the A, CNAME records etc are correct. DHCP's DNS is set correctly, GPOs are correct (even though they cant refresh cos of this problem!), the servers network adapter has its DNS set to 10.76.4.11. Just don't know. Very confused.

    Read the article

< Previous Page | 427 428 429 430 431 432 433 434 435 436 437 438  | Next Page >