Search Results

Search found 13909 results on 557 pages for 'old man'.

Page 432/557 | < Previous Page | 428 429 430 431 432 433 434 435 436 437 438 439  | Next Page >

  • Why won't dhclient use the static IP I'm telling it to request?

    - by mike
    Here's my /etc/dhcp3/dhclient.conf: request subnet-mask, broadcast-address, time-offset, routers, domain-name, domain-name-servers, domain-search, host-name, netbios-name-servers, netbios-scope, interface-mtu; timeout 60; reject 192.168.1.27; alias { interface "eth0"; fixed-address 192.168.1.222; } lease { interface "eth0"; fixed-address 192.168.1.222; option subnet-mask 255.255.255.0; option broadcast-address 255.255.255.255; option routers 192.168.1.254; option domain-name-servers 192.168.1.254; } When I run "dhclient eth0", I get this: There is already a pid file /var/run/dhclient.pid with pid 6511 killed old client process, removed PID file Internet Systems Consortium DHCP Client V3.1.1 Copyright 2004-2008 Internet Systems Consortium. All rights reserved. For info, please visit http://www.isc.org/sw/dhcp/ wmaster0: unknown hardware address type 801 wmaster0: unknown hardware address type 801 Listening on LPF/eth0/00:1c:25:97:82:20 Sending on LPF/eth0/00:1c:25:97:82:20 Sending on Socket/fallback DHCPREQUEST of 192.168.1.27 on eth0 to 255.255.255.255 port 67 DHCPACK of 192.168.1.27 from 192.168.1.254 bound to 192.168.1.27 -- renewal in 1468 seconds. I used strace to make sure that dhclient really is reading that conf file. Why isn't it paying attention to my "reject 192.168.1.27" and "fixed-address 192.168.1.222" lines?

    Read the article

  • vmdk Recovery after migration from 3.5 to 4 and fallback tentative.

    - by olgirard
    Hy, I've tryed to migrate some VM from my 3.5i environment to a brand new vSphere 4.0 U1. The two platforms are running simultaneously, sharing the same SAN. I Migrate my VM by stopping it, unregistering in vcenter (esx ver. 3.5, i call it esx3), register in vSphere (esx ver. 4, i call it esx4), and migrate upgrade virtual hardware before powering it up (First mistake). vMotion was enabled on esx4, seem to be a second mistake. After a day or so, i encountred problems joigning the esx server (esx4) and decided to unregister my server for esx4 and fallback to esx3. esx3 refused to boot, i supposed this was due to virtual hardware in Version 7 so i recreated a new VM pointing to the vmdk of the old VM. Everithing seemed fine until i log into the server and discover that i was running on the original disk ith every snapshots ignored even those created on esx3. I tried to reboot VM on esx4 but VM doesn't power up because "The parent virtual disk has been modified since the child was created". I've got a copy of a later state of the drive but generated between two snapshots (ovf generated with canverter standalone) as a backup. Do i have a chance to recover at least some files on the virtual drive or (as i tink) all is played, i've done enought mistakes for this time. Thanks for your help.

    Read the article

  • Disk Error on Boot (Possible boot sector issue)

    - by Choco
    I own a 4-5 year old Dell Dimension E510 with Windows XP: Media Center Edition. I have 2 drives installed: C Drive: Windows XP: Media Center Edition G Drive: 2 partitions: Windows 7 (beta) Windows XP (professional) That is also the order they are connected. The C Drive is my primary drive. When I attempt to boot the computer, the bios loading screen appears normally; the progress bar moves and it's fine. The very next page, however, supposed to be a boot choice. When I installed Windows 7 onto the G Drive in context of the C drive it added a boot selector to the C drive's boot sequence. It gives me the option of booting Windows 7 or Windows XP: Media Center Edition. However, my problem is now this: After the bios screen I previously mentioned, instead of a boot selector, I receive the following error: A disk read error occurred. Press CTRL+ALT+DEL to restart. The drive is spinning up normally. I hear no odd noises/clicks/scraping coming from it, even after disabling the other drive to listen to it carefully. According to me, it's a boot sector issue. I have never experienced this before, but maybe during a recent shutdown, Windows XP: MCE errored out and ruined the boot sector. Dilemma! I don't have the Windows XP: MCE disc, because it was installed by the factory. I have accessed the hidden partition on the drive before (you hit a key combination on the bios screen and it comes up with an interface to fix your drive). However, I don't want to reformat the drive (which is what the interface gives me the option to do). I want to possibly fix the boot sector. How can I achieve that?

    Read the article

  • Homegroup should be working, but doesn't

    - by Tim
    I have Win7 installed on both my PC and laptop. When I choose to make a homegroup I can go through the steps of creating, getting password, then joining it from the other computer and it says that it all connects properly. But when I go to the homegroup tab it always says no other computers connected. If I look in the settings it will say "connected to suchandsuch homegroup" but the comps won't show. Also, on my PC, when I tick the boxes in the homegroup settings on what libraries I want to share, then click on save settings, it shuts down the settings window and when I re-open it the library tick boxes are all unticked again. Yet, I have had no problems with the tick boxes stayin ticked on the laptop. I have tried cancelling and remaking the homegroup, have tried making it on both computers, and have tried disabling and re-enabling the network connectors but it still won't work. At my old house we had 3 PCs running win 7 and 2 of them could homegroup together fine but mine never could as it was getting the same problem I am getting now. I feel like I am the only one on the planet with this problem. Can anybody help?

    Read the article

  • Iptables Forwarding problem

    - by ankit
    Hi all, I had initally asked question about sertting up my linux box for natting for my home network and was given suggestions in the thread here. Did not want to clutter the old question so starting a new one here. based on the earlier suggestions, i have come up with the following rules ... :PREROUTING ACCEPT [1:48] :OUTPUT ACCEPT [12:860] :POSTROUTING ACCEPT [3:228] -A POSTROUTING -o eth0 -j MASQUERADE COMMIT *filter :INPUT DROP [3:228] :FORWARD DROP [0:0] :OUTPUT DROP [0:0] -A INPUT -i lo -j ACCEPT -A INPUT -i eth0 -p icmp -j ACCEPT -A INPUT -i eth0 -p tcp -m tcp --dport 80 -j ACCEPT -A INPUT -i eth0 -p tcp -m tcp --dport 443 -j ACCEPT -A INPUT -i eth0 -p tcp -m tcp --dport 22 -j ACCEPT -A FORWARD -i eth1 -p icmp -j ACCEPT -A FORWARD -i eth1 -p tcp -m tcp --dport 80 -j ACCEPT -A FORWARD -i eth1 -p tcp -m tcp --dport 443 -j ACCEPT -A OUTPUT -p icmp -j ACCEPT -A OUTPUT -j ACCEPT COMMIT If you notice, i do have the proper MASQURADING rule and the proper FORWARD filter rule as well. However i am facing 2 problems On the linux box itself DNS resolving is not working the lan clients connected to the linux box, are still not able to get to internet. when i ping something from them, i see the DROP count in iptables INPUT rule increasing. now my question is, when i am pinging something from the lan client, how come it is being matched by the input chain ?! should it be in the forward chain ? Chain INPUT (policy DROP 20 packets, 2314 bytes) pkts bytes target prot opt in out source destination 99 9891 ACCEPT all -- lo any anywhere anywhere 0 0 ACCEPT icmp -- eth0 any anywhere anywhere 0 0 ACCEPT tcp -- eth0 any anywhere anywhere tcp dpt:http 0 0 ACCEPT tcp -- eth0 any anywhere anywhere tcp dpt:https 122 9092 ACCEPT tcp -- eth0 any anywhere anywhere tcp dpt:ssh Thanks ankit

    Read the article

  • AWS Linux EC2: yum won't run with plugins

    - by Patrick
    Short Version: yum commands on my Amazon Linux EC2 AMI only work with --noplugins. Long Version: A couple of days ago, I ran yum update at the behest of the SSH Login MoTD telling me I had updates to install. About midway through the update (specifically while updating the kernel), the update abruptly ended (79 of 138 items completed). The website I host on EC2 got weird for a few minutes, but eventually seemed to stabilize back out (maybe EC2 restarted itself?), and I didn't have further issues (other than MySQL started running out of memory, but I think that's probably unrelated to this). Today, I went to install gcc-c++ (with yum install gcc-c++). When I did, I got the following message: Loaded plugins: priorities, security, update-motd, upgrade-helper Config error: Command "updateinfo" already defined and I get that for any command I can think to run using yum. However, If I throw in the --noplugins flag, then magically it seems to work. To be clear, when I installed a different package a week ago, it worked totally correctly, so the yum update is the only thing I can think of that changed. I could find nothing on Google with regard to "updateinfo" already defined (with and without quotes). I tried running yum update --noplugins which spit out a message telling me that I should have run yum-complete-transaction instead, but proceeded to try to update something on its own. When that completed, I tried yum-complete-transaction but that gave me a message about the transactions not lining up correctly, so it removed the old transaction (Probably since I should have completed the first transaction before trying to update again, if I had known). Based on the SF question "Linux EC2 Broken Yum", I've also tried yum clean all --noplugins (fails the same with plugins) which just gives me Cleaning repos: amzn-main amzn-updates rpmforge Cleaning up everything I also tried package-cleanup --problems Loaded plugins: priorities, update-motd, upgrade-helper No Problems Found and package-cleanup --dupes Gives a lot of dupes, so I pasted them here: http://pastebin.com/VVFQEkTT instead of inline. At this point, I'm not sure what else there even is to check.

    Read the article

  • IIS doesn't serve certain file extensions

    - by Alekc
    Hi, i have this weird issue on Win 2k3 server and IIS: Iis has several sites, in one of them i need to create a subdir and set up it as web application. I've noticed that if i create new directory and put some .js/.txt file into it, they will not be served by iis (IE gives an error Internet Explorer cannot display the webpage). If i put the same files in another old site's subdirectory it will show correctly. By sniffing traffic i've seen that iis reply connection state 200 and then drop completely any connection http://domain.com/test2/prova.txt GET /test2/prova.txt HTTP/1.1 Host: domain.com User-Agent: Mozilla/5.0 (Windows; U; Windows NT 5.1; en-US; rv:1.9.1.7) Gecko/20091221 Firefox/3.5.7 (.NET CLR 3.5.30729) Accept: text/html,application/xhtml+xml,application/xml;q=0.9,*/*;q=0.8 Accept-Language: en-us,en;q=0.5 Accept-Encoding: gzip,deflate Accept-Charset: ISO-8859-1,utf-8;q=0.7,*;q=0.7 Keep-Alive: 300 Connection: keep-alive HTTP/1.x 200 OK If i rename file prova.txt in prova.asp for example it showing without problems so it shouldn't be permissions issue. After making some researches I've found out that it can be caused by missing mime types, I've checked out .txt and .js are present and served by aspnet_isapi.dll. And here comes another weird thing: if i remove mime mapping from directory's properties it's served correctly, but the same thing doesn't work with js. I'm really beginning to be out of ideas, is there someone who have some hint? Thanks in advance.

    Read the article

  • Archiving mails with postfix: how to filter mails?

    - by Tronic
    i wanto to implement the following scenario: we use a postfix mailserver. to archive all old and new mails, i want to setup a second postfix on our fileserver and create a single mailbox "archive". then every mail gets forwarded as bcc to this mailbox automatically. now, i want to create different folders in a maildir structure and let the server move each mail to the right subfolder of the mailbox based on its sender or receiver. e.g. when we get a mail to one of our employees named "John Doe" at [email protected], the mail should be moved to "Inbox/John Doe Incoming". the same applies when john doe sends a mail, folder would be "Inbox/John Doe Outgoing". how can i implement this filter behaviour. i heard of Procmail and Maildrop. Which of the two would you prefer? Which is more easy to configure? Any out-of-box solutions here? thanks in advance!

    Read the article

  • Warning for "Reallocated Event Count" S.M.A.R.T. attribute with a new/unused drive. How serious is t

    - by Developer Art
    I've just looked at the health status of my old 2,5 inch 500 Gb Fujitsu drive with a popular "HD Tune" utility. It shows a warning for the "Reallocated Event Count" property. How serious is that? The thing is that the drive is practically new. I pulled it out of a new laptop over a year ago and never used it since. Right now it only has 53 "Power On" hours which sounds about right since I only had it running a few evenings overnight before switching it for something more performant. Does this warning indicate that the drive is likely to fail some time in the future? I'm somewhat perplexed since the drive is effectively unused. What is more, I have arranged with somebody to buy off this drive since I don't really need. It is 12,5 mm thick (with 3 plates) meaning it doesn't fit into an external enclosure which makes it quite useless to me. Can I give away the drive without having it on my conscience or better cancel the deal? In other words, can the drive be used safely for years to come or better throw it away? I'm running a sector test now to see if there are any real problems. Will post the results as soon as they're available.

    Read the article

  • Identify differences between MP3 files

    - by Thingomy
    I have 2 old similar directory trees with MP3 files in them. I am happily using tools like diff and Rsync to identify and merge the files that are only present on one side, or are identical, I'm left with a bunch of files that are bitwise different. On running diff over a pair actually different files, (with -a tag to force text analysis) it produces incomprehensible gibberish. I have listened to files from both sides, and they both seem to play fine (but at nearly 10 minutes per song, when listening to them twice each, I haven't done many) I suspect the differences are due to some player in the past "enhancing" my collection by messing about with ID3 tags, but I can't be certain. Even if I identify differences in ID3 tags, I would like to confirm that no cosmic ray or file copy error issues have damaged any of the files. One method that occurs to be is finding the byte locations of the differences, and ignoring all changes in the first ~10kb of each file, but I don't know how to do this. I have on the order of a hundred or so files that differ across the directory tree. I found How to compare mp3, flac audio data in a file, ignoring header data (ID3 tag) etc.? -- but I can't run alldup due to being Linux only, and from the sounds of it, it would only partially solve my issues anyway.

    Read the article

  • How to get multipath working for Ubuntu Server 12.04

    - by mlampi
    I'm working on a project which aims to make use of Ubuntu servers running on enterprise class hardware. In our case that means IBM HS23E blade servers, QLogic 4GB fibre channel extension cards and quite old IBM DS4500 disk array with two controllers. At the moment we have fibre channel as only boot option and Ubuntu Server 12.04 installed just fine and is able to boot without multipath. I'm not a linux professional myself but in our team we have people who will understand the technical stuff. Don't let my post confuse :) The current situation is that we have only one fibre channel connection to a single disk array controller. Real life case would be of course quite different. At minimum we should have two fibre channel ports connected to two different switches and two different controllers. However, we have no idea how to set up multipath tool. Is the DM-MPIO the right software? At minimum we should be able to boot when multiple connections are available and achieve fault tolerance when any of them should be down. Since the disk array is not the latest hardware, I managed to find RDAC driver sources only for 2.6.x kernel. And we have 3.2.x. Another issue is to build a multipath.conf. The said driver sources are from IBM support and the QLogic drivers provided to Ubuntu installer are from Ubuntu site. It seems that RHEL and SLES would have near out of the box support but that is not an option for our project. Actual questions: - What is the recommended software tool for multipath for Ubuntu Server 12.04? - Is there available pre-made configurations or templates? Does it require disk array / controller specific settings or do a more generic config work? - Do you have expriences on similar setup and like to share the knowledge? I'll provide you with any additional information you might require. Thanks in advance.

    Read the article

  • Linux DHCPD Mac-Address based Groups

    - by GruffTech
    Our Current DHCPD.conf looks like the following. subnet 10.0.32.0 netmask 255.255.255.0 { range 10.0.32.100 10.0.32.254; option subnet-mask 255.255.255.0; option broadcast-address 10.0.32.255; option domain-name-servers 208.67.222.222,208.67.220.220; option routers 10.0.32.5; host Dev-ABaird-W { hardware ethernet 00:1D:09:3E:49:13; fixed-address 10.0.32.94; } ... more static hosts .... } About as basic as it gets. The old router is 10.0.32.1, our company wanted to implement a squid proxy to better monitor web traffic while at work, and if necessary block large time-wasters, IE Facebook.com. However, we've quickly realized that this change has played a mean prank on our Polycom SIP Phones. Occasionally our phones will not ring, the end recipient hears ringing (this is artificially created by our PBX) however the handset never rings. The ONLY thing that has changed in our network is the option routers line. So, Since all Polycom MAC addresses begin with 00:04:F2 would it be possible in DHCP to say any 00:04:F2:::* MAC addresses get option routers 10.0.32.1, and anything else must talk with our Gateway?

    Read the article

  • Changes to grub in ubuntu 10

    - by jdege
    I've been running CentOS 5 for some years. I've decided to upgrade to Ubuntu, and with 10.04 just out, this seemed like a good time. I'm a tad paranoid, so I started off with a new set of drives - one to install on, one to backup to, and one as a spare. I removed my existing CentOS 5 drives, and did an install, and had no problems. I installed the server version, and used the default full-disk LVM installation. Next, I copies my backup scripts over, edited them to work with the new configuration, and did a test backup. That worked fine, as well. Then comes the real test, could I do an install of the backup onto the spare drive? (I won't put anything of importance on a system that doesn't have a reliable backup, and if I've never done a restore, it's not reliable.) I booted from a System Rescue CD (ver 1.5.3), with the spare drive as /dev/sda, and the backup drive as /dev/sdb. I had no trouble in partitioning, configuring LVM, formatting, making swap, or restoring the file systems. But when I got to restoring grub to the MBR, I ran into problems. My restore instructions from CentOS 5 said run grub, then enter two commands: root (hd0,0) setup (hd0) The first command exits with an error: "Checking if /boot/grub/stage1 exists ... no" I did some googling around, and found that the Grub2 included in recent Ubuntus is very different than the Grub 0.97 included in CentOS 5. One site suggested I use: grub-install --root-dir=/mnt/restore /dev/sda That appeared to work, but when I booted from the drive, I ended up at a grub prompt. Any ideas as to what I need to do? It seems like a simple problem, but my attempts at searching out answers on the web are being swamped by references to the old version of Grub. Help would be appreciated.

    Read the article

  • Enable CPU fan always on

    - by Gundars Meness
    I am using 3 years old overheating laptop and I want my CPU fan to be spinning 24/7 regardless of the consequences. How to make it spin? The problem is that CPU & GPU heats up to 68°C (154 F) right after boot and never goes down, because CPU fan is not spinning full throttle. It starts spinning faster when temperature goes over 70°C and stops when it reaches seventy again. When doing heavy work on databases, it gets from 70 to 90 in no-time and automatically powers off. Bios does not contain any "fan spin 100%" options, just "spin slowly all the time" and "auto" which is more useless than the first one since my fan doesn't have pwm wire. Currently I'm solving this with cooling stand (3x5V), but it isn't much of a help. I would rather use the CPU fan since it is the only fan directly responsible for cooling down CPU/GPU. But how to make it spin 100% all the time? Should I attach it's red power wire to motherboard to get constant 5V (is there such option?), or is there an option to control it via software? Laptop: Samsung R528 2.3 GHz Intel i3 with Nvidia GeForce 310M Bios: Phoenix 03KT.M003.20100622.KSJ (and that is latest update) OS: Ubuntu 12.04.2 LTS with 3.2.0.51 kernel CPU fan: Image/Description Has 5V 0,4A and only 3 pins, no pwm. P.S. Yes, I did clean everything with alcohol, freed the air vents, changed thermal paste etc; that reduced temperature by 4 degrees.

    Read the article

  • Effective backup and archive strategy for database and linked files

    - by busyspin
    I am using Postgres to store a variety of application data for a webapp. Part of the application involves storing and retrieving user uploaded files. I am storing the files in the filesystem with some associated metadata in the database. I am trying to come up with a backup and archive strategy so that I can effectively backup and archive/restore the database and the linked files. Here are the things I want to accomplish. Perform routine backups that can be used for recovery from failures and which include all DB data and the linked files. Ideally, this backup would be done while the app is running. Live backup is certainly possible with a DB but I am not sure how to keep the linked files consistent with the database during the backup process Archive chunks of data as they become "old". These chunks must includes the database data plus any linked files. It should be possible to put the archived data back into production again. It would be ideal if it were easy to determine which ranges of objects were stored in each chunk. Do you have any advice for how to accomplish these goals? If the files were in the database as BLOBS these tasks would be much easier since normal database backup and restore functionality would handle this. I am not sure how to accomplish the same thing when file data is linked to database rows.

    Read the article

  • How to run the CPU at something like 75%?

    - by Tobias Kienzler
    My notebook is too old for me to invest into a new fan (it will simply be replaced by a new one when the final heat death occurs), but when it runs on full speed I feel like sitting in front of a vacuum cleaner with integrated cooking... I'm currently using NHC, the Max Battery mode of which let's the CPU run at 50% (~800 MHz). That's fine for most applications, and both temperature and noise remain low. However, on some occasions I need a bit more speed, more around 75% maybe. Can I set the power saving settings somehow so that the CPU won't surpass 75% of it's capability so that an acceptable compromise between power and noise is achieved? I can't set the CPU frequency in the BIOS and since on rare occasions I'd like to be able to switch to 100% without much hassling, hardware solutions like setting jumpers are no option. This answer to a similar (linux!) question mentions NHC should be able to offer these options, but for me they are all greyed out: The notebook is an Asus Z9200K, I guess NHC doesn't support its chipset enough for these advanced options.

    Read the article

  • how to authenticate once for multiple servers, using only apache configs?

    - by Wang
    My problem is, I have a number of prepackaged web apps (a print system, a wiki, a bug tracker, an email archive, etc.) running on different Mac OS X Leopard (soon to be SL) servers that each need to authenticate users from the internet at large. Right now every server presents an Apache basic authentication prompt, which takes a shared login, but it's apparently enough of an inconvenience to log in repeatedly that people are sending email without checking the wiki or bug tracker or archive. In the case of the bug tracker, a user [might need to log in twice---once for apache if he hasn't used any other protected service on that server, once for the bug tracker itself so it can distinguish different people. Since the only common component to all these apps is Apache 2 itself, does it have any way of authenticating a user once, in some way that will be respected by other servers and various web apps? Looked at http://serverfault.com/questions/32421/how-is-session-stickiness-achieved-across-multiple-web-servers but it sounds like the answer is assuming that I get to write my own web app. Looked at Ian Bicking's blog but it's four years old and recommends something available only for apache 1.3, not apache 2. Sorry not to hyperlink the second site---apparently I need 10 reputation points. Edit: Shibboleth does what I need, but I should have specified that I'm looking for a really dumb, really simple solution for in-house services that need to handle all of a dozen users, probably not more than three at a time.

    Read the article

  • Should be simple: existing laptop with local user and outlook 2007 migrate on same computer to domain user with outlook 2007 emails intact

    - by bifpowell
    I have Dell Laptop with windows 7 64 bit and for the last year it's been just a machine with an account like: machine\john there are files in folders and stuff in c:\users\john and john uses outlook 2007 as a pop3 client and has identifiable local appdata pst files. Now I installed a server and want to have everything be domain-centric so I added this laptop to the domain with admin credentials and then logged in as a domain user as: domain\john.smith Now I want to duplicate machine\john (outlook emails mostly) to domain\john.smith. In the past I used the Files and Settings Xfer Wizard and done. I tried that here and it crunched away for a while, made the file, but the restore had no effect - it ran for a while, had a progress bar, but it's like nothing happened at all afterwards. I've rebooted the machine, logged in as domain administrator as the first user to log on after the restart and tried: c:\users\john xcopy c:\users\john c:\users\john.smith /V /C /F /H /K /Y /E ...and it copies some of it, but when it gets to c:\users\john.smith\appdata\local\application data it chokes "Access denied, unable to create directory" I also tried logging in as domain\john.smith and copying the entire directory that the PSTs are in from machine\john and a lot of the mail was there when I launched outlook after replacing the PSTs, but not all of them??? I got errors about files in use when doing this method, which I figure must be why not all the old emails are in the inbox?... There must be some extremely simple way to do what must be a very common requirement. Any guidance appreciated.

    Read the article

  • windows 7: Event 55 The file system structure on the disk is corrupt and unusable

    - by Radio
    Here is a real bad one! Windows 7 RTM with SP1 installed [Version 6.1.7601]. Recently tried to delete some folder on my hard drive and Windows prompted "Error 0x80070570: The file or directory is corrupted and unreadable", and at the same time placed an Event 55 describing "The file system structure on the disk is corrupt and unusable. Please run the chkdsk utility on \Device\HarddiskVolume2." Ran chkdsk, first with /f option, then with /r option. Result in both cases was: no errors found, 0 bad sectors. No problems chkdsk found at all! Went through StackExchange, Google and spent over 6 hours on this. Still cannot figure out the problem. Re-installing/Re-Formatting is not an option! What did I try: Hotfix - Windows6.1-KB982927-x64.msu - gave me an error about incompatibility with my computer, however it totally matches my system. CRC of hotfix was ok. Windows Repair Console found startup errors and fixed those, but this didn't help an issue, even by running chkdsk c: /R from it. http://support.microsoft.com/kb/246026 does not promise anything good. sfc /scannow does not help too. Replaced hard drive by cloning an old one using True Image, repeated all steps above. At the same time, some minor glitches started to appear in my Windows, like side panel and notification area settings are getting reset. Goal is to delete the folder and get rid of Event 55. Sounds like NTFS bug. Please help. This is completely ridiculous.

    Read the article

  • Small Business HP Virtualisation and iSCSI SAN Options

    - by Robin Day
    We are a small business that hosts our core product on a number of HP servers. Our core production setup is 1x HP DL380, high powered for a SQL Server Database 1x HP DL360, mid powered for our core application server 6x HP DL320, low powered for our front ends We run our training / testing / support systems on a similar setup, the servers are just older and less powerful. Unfortunately this is now causing us issues as the system has grown beyond the capabilities of these older servers. Upgrading these servers would be expensive and we believe that virtualisation is probably the way to go for the future. Locally we run a number of test / dev environments on ESXi using Direct Storoage on a couple of high powered DL360's and these are performing fairly well. We're thinking that instead of replacing all of our test servers that we can implement an iSCSI SAN and one or two high powered hosts. Hopefully looking that when it comes to replace our live servers as well that we can just expand the virual environment to cope. So my question is... Can anyone offer any advice on some suitable options? We have generally always been extremely happy with HP servers, all of our kit is currently HP, therefore our preference would be to stick with HP, however, I'm always happy to hear about other options. I'm hoping that initially a budget of around 15-25k (GBP) would be suitable, this could potentially be increased if I had confidence that the system would pave the way for a cost effective upgrade of our live systems in the future as well. I am new to SAN's and my only real experience is playing with OpenFiler on some old desktops. I think iSCSI should be suitable, but I've not done any research into how SQL server may perform. I've had a browser through HP's sites and see plenty of information about EVA, MSA, LeftHand, etc. However, from looking at all that, I don't see which options would be best and more importantly I don't know exactly what I would need to buy. Any help, links, opinions would be much appreciated. Thanks

    Read the article

  • PC powers off at random times

    - by Timo Huovinen
    Short Version After experiencing some problems with Mobo batteries my PC started to power off at random times, the power off is instant and sudden and does not restart afterwards, need help figuring out the cause. Facts: Powers off when PC is playing games Powers off when PC is idle Powers off when PC is in safe mode Powers off when PC is in BIOS Powers off when PC is booted through a Windows installation USB Replaced the motherboard battery several times Replaced the 650W PSU with a 750W PSU Replaced the RAM Swapped the RAM between slots Re-applied thermal paste to the CPU Checked if the motherboard touches the case Nothing is overclocked PC Specs PC specs: OS: Windows 7 Ultimate SP1 RAM: klingston 1333MHz 4GB stick CPU: AMD Phenom II x4 955 Mobo: Gigabyte 88GMA-UD2H rev 2.2 Motherboard battery: CR2032 3v HDD: 500GB Seagate ST3500418AS ATA Device Graphics: ATI/AMD Radeon HD 6870 Very Long version Around 10 months ago I built a brand new gaming PC. Around 6 months ago it's time setting in windows started resetting to the year 2010. I swapped the Motherboard battery for a new one of the exact same size and shape and voltage, and the problems disappeared...for around 2 weeks. Then the same problem happened again, time gets reset, I swapped the battery again, and the problem was gone for good and everything was great for about 3 months.. then another problem started happening, the PC started to power off suddenly and without warning at completely random times, sometimes the PC works for and hour, sometimes 5 minutes. So I read on the forums that it might be either the PSU or the motherboard Battery or RAM or HDD or the Graphics card or the CPU or the motherboard or the drivers or a Virus or Grounding issues, or something short circuiting, basically it can be anything... I spent some days researching, and decided to remove the possibility of a virus. I reset the CMOS, cleared all BIOS settings and reinstalled windows 7 after a full format of the HDD, but the random power off kept happening. I then disabled the restart on error option in windows and looked at the event log for error events, but they did not help me figure out the problem. Network list service depends on network location awareness the dependency group failed to start Source Kernel Power Event 41 Task Category 63 Source Disk Event ID 11 Task Category None The driver detected a controller error on device disk I took apart the PC, every little piece, re-applied some expensive thermal paste to the CPU, and double checked that none of the pieces are touching the PC case. The problem was gone, the PC no longer powered off randomly I re-attached the graphics card and all was good for 4 months... then the power off problem appeared again, but was happening at high intervals, the PC would shutdown once in 2 days on average, at random points in time, sometimes when it's idle all day long, sometimes when it's running CRYSIS 2. I checked the CPU temperature, because I know that AMD CPU's have a built in protection mechanism that switches off the PC if the CPU gets too hot, and the Temp was 50C system temp, and 45C CPU after running the PC all day long (I did not do tests to see if there are any temperature spikes, don't know how to do them) Originally the PSU that powered the PC was 650Watts and had one 4 pin cable to power the CPU, I replaced it with a new 750Watts PSU which has two 4 pin cables for the CPU, but the problem remained. I removed the graphics card and let the motherboard use the built in one, but the PC kept suddenly powering off at random times. I took apart the PC completely again, and re-applied thermal paste to the CPU, added lots of insulation, and checked for any type of short-circuit possibility again and again, but the problem remained. The problem was like that for some months. I replaced the Battery a couple of times over the time, changed lots of options in windows, and tried everything I could, but it kept powering off, so I stopped using the PC as much as I used to, just living with the random power offs from time to time, until a couple of days ago, when the power off happens almost immediately after powering on the PC. I replaced the RAM with a brand new one, but that did not help. Took apart the PC again, checked for anything anywhere that might cause it, found some small scratches on the very edge of the motherboard to the left of the PCI express x16 slot. This might cause the problem, I thought, but the scratch looks very superficial, not deep at all, and if the scratch did harm the motherboard, wouldn't it cause it to not start at all? And why did it start to power off a while ago, and then suddenly stop powering off? The scratches could not have vanished??? did chkdsk \d but it powered off when it was at 75% I removed the hard disks, the graphics card, while I fiddled with the BIOS settings, and suddenly the PC shut down while I was looking at the BIOS version. This makes me realize, it is not caused by: HDD, Windows, Drivers or the Graphics card I cleared the CMOS again, updated the BIOS from F5 to F6f beta, but that did not help, it might even seem that the PC powers off even sooner. The shutdown even happened to me while I booted through a windows 7 installation USB and was in the repair console. I removed one of the cables powering the CPU, now only one 4pin cable powers it, and it worked for 30mins after doing that, which makes me think that it's the CPU overheating, and because it gets less power, it overheats slower? The things that I am still considering: CPU overheating (does not seem to overheat, maybe false readings?) Motherboard short circuiting (faulty motherboard?) I desperately need some advice in what is faulty, is it a faulty Motherboard or an overheating CPU? or maybe something else? I have been breaking my head over this problem over a span of 6 months. I'm not sure if this is a good place to ask this question, if it is not, then tell me where I can get some experienced help. More info I have also discovered a mysterious piece that seems to have fallen out of the motherboard i119.photobucket.com/albums/o126/yurikolovsky/strangepiece.jpg What is it? Looks like each time that it powers off the datetime gets reset I also found another forum post tomshardware.co.uk/forum/… except I don't have Integrated PeripheralsUSB Keyboard Function option in BIOS :S Comments summary (asked by Random moderator) Q. tell me, if the computer restarts, is it immediately? Does it take a second and then restarts? Do you see (BSOD) or hear (PSU, short circuit) any suspicious when it happens? After reading trough it, it remains the mainboard that is faulty. – JohannesM A. Immediate power off, all the fans stop instantly, all the light turn off instantly, no sound or anything, and it remains off until I turn it back on. Thanks for the feedback, faulty motherboard is what I fear. Q. Try stress-testing the system with Prime95 and see if errors or shutdowns occur when the CPU is under full load. – speakr A. Prime95 heat stress test peaked CPU heat at 60C after 5mins, it powered off after 30mins of testing in the middle of the test with no errors, Prime95 Heat test or the stress-testing with low RAM usage (small or in-place FFTs) do not report errors while testing for 10-60 mins. The power off does not seem like it is affected by Prime95 at all Makes me wonder if it's a CPU or Motherboard issue at all. Q. I had similar random/intermittent problems with my old board. It gave one of a few different symptoms: keyboard and/or mouse would die and/or the RAM wouldn't work and/or it would shut down. It was in bad shape. One problems was that my old PSU had literally burned the connector on it (browned around the pins), another was that a broken lead inside the layers of the PCB would work sometimes if it happened to be hot or if I bent the board—by jamming a hunk of wood behind it. I managed to keep the board alive for several years, but eventually nothing I did would make it work correctly anymore. – Synetech A. I will try that as the last resort, ok? ;) Q. Have you tried a different power cord, surge protector, outlet (on a different circuit). It's worth a shot just to ensure it's not subpar wiring or a week circuit (dips in power may cause shutdown if the PSU can't pull enough juice from the wall). – Kyle A. yes, I attached the PC to an entirely different outlet on a different circuit and the problem persists. After connecting it to a different outlet after starting the PC it gave me 3 long beeps and 1 short one, then the PC immediately proceeded to boot up normally. Q. Re-check your mainboard manual and all PSU connections to your mainboard to be sure that nothing is missing (e.g. 12V ATX 4-pin/6-pin connector). If you can provoke shutdowns with Prime95, then consider buying new hardware -- a stable system should run Prime95 for 24h without any errors. Prime95 mentions errors in the log when they occur and gives a summary after the stress test was stopped manually (e.g. "0 errors, 0 warnings", if all is fine) – speakr A. Re-checked, there are no more PSU connectors that I can physically connect, except the one ATX 4-pin (there are 2 that power the CPU) that I disconnected on purpose, I have reconnected it but the problem persists. Q. With one PC I had a short curcuit. The power button on the front plate had its cables soldered, but not isolated, and the contacts were very close to the metal case. A heavier touch was enough to cause a shutdown. The PC's vibration could be enough – ott-- A. yes, it seems to switch off with even the lightest touch, I switched on the PC, then pulled out the front panel power cable that connects to the motherboard so the power button does not work anymore, after 5 mins of working like that, with the power button completely disconnected, just sitting idle, the PC powered off again, I don't think it's the power button. Q. I wonder if you dare to operate components without the case, that is remove motherboard, power, disk ( just put the motherboard on a wooden desk). Don't bend the adapters when running like that. – ott-- A. yes, I do dare to do that, but only tomorrow, too tired/late right now.

    Read the article

  • prevalent, recurring hardrive failure intel macbook from 2006/2007

    - by SimonSalman
    Hi, Long story: My MacBook's hard drive failed one year ago, just a month after its warranty ended or: a year and a month after I bought it. After about ten phone calls to Apple's service, they agreed to extend the warranty for another year, so that I got it replaced free of charge. In the mean time, I got to know that many MacBook users that experience/report hard drive failures. Every reported crash was preceded by a slowdown of system performance, an increased occurrence of the spinning beach ball wait courser, and frequent crashes of applications that used to run very robust until then. It happened (as far as I know) with MacBooks from 2006/2007. All these MacBooks additionally suffer from a recurring wearing down of their "top case". Many heavy users had to replace their HDDs three time since 2006/2007 resulting in an head crash, making it impossible to recover data (diagnosis of recovery specialists) in most but not all cases HDD was Seagate (doesn't necessarily have to be the cause, if majority of the MacBook charge contained Seagate drives) And right now (one year after my first disk crash), these symptoms are cumulating on my system, again ... Short version: prevalent hard drive failure on MacBook charge from 2006/2007 (i.e. 2.16 GHz Intel Core 2 Due) I am looking for any (preferable open source) tool for checking the hard drive condition, especially to detect the known "MacBook problem". So, that I can replace the disk on time. If any Mac user found a solution to prevent the repeated failure of heir hard drive, I would be very glad to get to known it. I really enjoy my old MacBook, but I hate to get interrupted every year by an HDD crash. BTW, the issue is already in discussion for a long time, but there seems to be no solution, so far. Thanks, Simon

    Read the article

  • Convert a cassette tape recording to digital format

    - by Electric Automation
    Has anyone been successful with transferring audio cassette tape recordings to a digital format? I would like to preserve old cassette tape recordings of my grandparents to some digital format: MP3, WAV, etc... The quality of the tapes are mediocre. I think I can handle the quality restoration but getting the audio from tape to digital is my question. Below is a list of the hardware that I can work with: Cassette Deck: I have a Technics stereo cassette deck model RS-B12. It has separate left and right IN and OUT RCA type jacks on the back. In the front it has a headphone phono jack, plus left and right mic input phono jacks. On the computer side: -I have a Windows Vista PC with no additional software other than what came with the machine from Costco. No sound editing software that I can see. There is no sound card on the PC. On the front panel there is a mini-phono mic input jack and there are several different types of in/out mini-phono jacks on the back. In addition, USB and Firewire. I also have access to a new (2009) iMac with a mini-phono input jack for a powered mic or other audio source and GarageBand that has come with the computer. In addition, USB and Firewire. What are my options for getting these cassette recordings into a digital format? Whats the best format? What sort of wires would I need and will I want to utilize the USB or Firewire or can I simply use the audio inputs on the PC (or Mac) to receive the audio stream?

    Read the article

  • Scanning website for vulnerablities

    - by Kristen
    I have found that the local school's website installed a Perl Calendar - this was years ago, it has not been used for ages, but Google has it indexed (which is how I found it) and it full of Viagra links and the like ... program was by Matt Kruse, here is details of the exploit: http://www.securiteam.com/exploits/5IP040A1QI.html I've got the school to remove that, but I think they also have MySQL installed and I'm aware that out-of-the-box there have been some exploits of Admin Tools / Login in old versions. For all I know they also have PHPBB and the like installed ... The school is just using some cheap, shared hosting; the HTTP response header I get is: Apache/1.3.29 (Unix) (Red-Hat/Linux) Chili!Soft-ASP/3.6.2 mod_ssl/2.8.14 OpenSSL/0.9.6b PHP/4.4.9 FrontPage/5.0.2.2510 I'm looking for some means of checking if they have other junk installed (quite possibly from way back, and now unused) that might put the site at risk. I'm more interested in something that can scan for things like the MySQL Admin exploit rather than open ports etc. My guess is that they have little control over the hosting space that they have - but I'm a Windows DEV, so this *nix stuff is all Greek to me. I found http://www.beyondsecurity.com/ which looks like it might do what I want (within their evaluation :) ) but I have a worry about how to find out if they are well known / honest - otherwise I will be tipping them a wink with a Domain Name that may be at risk! Many thanks.

    Read the article

  • USB drive dead after stopping copying process on Snow Leopard Server

    - by Anriëtte Combrink
    Hi there I was copying to a flash drive from our Snow Leopard server when I stopped the copying process half way through. The device then disappeared from the Desktop. So I unplugged it and plugged it right back in. The device just didn't show up. I unplugged it and plugged it into a Windows XP machine as well as a Windows 7 machine. On both machines, I right clicked "My Computer" and selected "Manage…". On both PC's, the device was located under Removable Storage, but had no size and no drive letter. It shows up in "My Computer", but when I choose "Format…" from the right-click menu (context menu), it says the drive could not be formatted. Can someone please advise me? The flash drives is about 5 mins old and should have no reason to be dead. I really can't loose this drive (I don't need the data on it, I just need it to work again), any help would be appreciated. Thanks in advance.

    Read the article

< Previous Page | 428 429 430 431 432 433 434 435 436 437 438 439  | Next Page >