  • VMware vSphere Hypervisor 5 with Intel SPL 5000 in Raid 0 no boot from DVD?

    - by Richard
    I hope this is the correct StackExchange, since I am only using StackOverflow for Web development, but need some help with my server configuration. I would like to install VMware vSphere Hypervisor 5 on my server here at home and run a view machines on it such as Windows Server 2008 and Red Hat. I used to have either OpenSuse or Windows Server 2008 installed but I would like to get into VMWare Hypervisor. My hardware configuration: - Intel S5000PSL with bios version S5000.86B.10.60.0091 build date 10/09/2008 as of read out of bios - E5420 @ 2.5GHz Intel Xeon CPU The Intel Virtualization Technology is enabled in the BIOS - DVD DH20A4P DVD Writer - 8GB ECC Ram I have configured a RAID 0 on my 2 WD 2TB SATA drives I have burned the Hypervisor 5 on an empty DVD and it is bootable, I tested it on my client PC. The main problem here is basically, that I cannot boot the DVD on my server. I have set the Boot Option to the DVD drive. I have booted from the BIOS straight in the DVD drive and it does not work. I do not see any error messages. The only thing I see are the PXE error messages when it tries booting from the network and other devices, obviously without any result. Does anybody know why I cannot boot the DVD? What could cause the problem? I have sucessfully installed Windows Server 2008 via original DVD about 1 year ago, so the DVD drive can read and does work. The DVD drive is available in the BIOS and I have checked all cables and none of them is loose in any way. I even see the light flashing but it does not want to boot from the DVD. I am looking forward to suggestions and things that I should check. Thank you very much

    Read the article

  • Is my HDD dead forever?

    - by Roberto
    Yesterday I turned on my computer and it couldn't boot. I found out the hd (320GB SATA Seagate Momentus 7200.3 for notebook) was broken and it couldn't be recognized by the BIOS. I have another of the same hard drive, so I exchanged the boards. I found out that there is a problem on its board since my good hard drive didn't work. But the broken hard drive doesn't work with the good board as well: it can be recognized but when I insert a Windows Instalation DVD it says the hard drive is 0GB. I put it in a case and use it in another computer via USB, and but it doesn't show up in the "My Computer". I used a software to recover files called "GetDataBack for NTFS", it recognized the hard drive but with the wrong size (2TB). I try to make it read the hard drive but it got an I/O error reading sector. It tries to read, the hard drive spins up. So, since I'm using a good board on it, the problem seems to be internal. Is there anything someone could do to recover the files from it?

    Read the article

  • New Computer freezing up at random

    - by Benjamin Frost
    Since I built my system about 4 weeks ago I'v been getting random freezes, Sometimes it can happen directly after startup and sometimes it wont freeze up for 3-4 days of 24/7 running. It seems to be happening under all stress loads but mainly when the CPU is under 10% load. It doesn't give me a BSOD or anything, it simply just freezes and repeats the last sound before the freeze until I shut it down by the power button. I'v re-seated everything in the system except the CPU, Cleaned the RAM sockets and gold fittings. None of the components have been clocked above their factory settings as of yet, don't want to overclock them until I sort out these freezes. Temps are all well under the rated max temps, the highest the temps have been are below CPU: Low load: 16-21°C Full Load (100%) 40-43°C *(From HWMonitor by CPUID) GPU 1: Low Load: 25-30°C Full Load (100%): 45-50°C GPU 2: Low Load: 23-27°C Full Load (100%): 45-50°C *(GPU Temps from Catalyst Control Center) General Case temps Rear: 18-20°C Mid: 20-21°C Front (HDD/SSD Bays): 14-19°C (Case temps may be a little off as it's from the Kaze master pro fan controller) I have Un-installed EVERY driver for Motherboard, GPU & Soundcard and Re-installed twice. Windows is all up to date. To date i'v tried the following Running Memtest for 24 hrs straight, No errors Running Memtest on each individual RAM modules, No errors Reseated everything except the CPU Cleaned DIMM Sockets and Gold inputs Tested the Graphics cards 1 at a time Re-arranged all the SATA devices to run on Chipset controlled ports Re-installing all drivers OS: Win7 Professional 64bit Motherboard: ASRock X79 Extreme9 CPU: i7 3930k 3.2GHz GPU: Sapphire 7950 OC Edition V2 (2 card Crossfire) RAM: G.Skill Ripjaws Z F3-17000CL11Q-16GBZL 16GB (4x4GB) DDR3 Boot Drive: OCZ Agility 4 128GB Data Drive 1: Western Digital Black 2TB Data Drive 2: Western Digital Black 2TB Data Drive 3: Western Digital Green 3TB Power Supply: Corsair AX1200 Gold

    Read the article

  • High Apache CPU usage, but low nginx - Configured correctly?

    - by Buckers
    We've just moved a website of ours over to a brand new high-spec Linux server (1x Intel Xeon E3-1230 v2 @ 3.30GHz, 8GB DDR3 ECC, 2x 128GB SATA SSD RAID1). The server has been configured to use nginx but we're not sure if its working correctly. The site always loads very fast to us (http://www.onedirection.net), but Plesk often sends us reports that the Apache CPU usage percentage reaches high leves, yet when we look at the nginx percentage it's always very low. We've come from a Windows background so are very new to Linux, but shouldn't nginx run INSTEAD of apache? Here's a screenshot from Plesk showing the CPU usage: http://www.pixelkicks.co.uk/_download/plesk.JPG The website gets around 20,000 visitors per day, and we use W3 Total Cache to get it running as fast as possible. MySQL has been optimised well. Memory usage is only running at 2GB of the 8GB. Does this look right? How can we tell that nginx is doing most of the work? Thanks, Chris.

    Read the article

  • Increasing SQL Server / Sage performance with SSD? (Dell PE T410)

    - by Anthony
    I have a client wanting better performance of their Sage (Accpac & CRM) server (v5.5, soon to be v7). It's running on 1 of 2 Hyper-V VMs (Svr2008) on a Dell PE T410 server with 24GB of RAM (1333MHz) & dual quad-core, and both VMs (only their C: drives) are on a single RAID5 array. All clients connect via 1Gb ethernet. The 2nd VM is SBS2008 with 9GB RAM (& all SBS dbs & company data are on a separate RAID5 array), & 3GB RAM for the Svr2008 hypervisor. I've given the Sage/SQL Server VM all the RAM I can (12GB) & SQL Server RAM caching (~8GB, never exceeds ~7.5GB, eg. entire db can now be cached in RAM) and that's helped significantly. Upgrading the Hypervisor to Svr2012 is an obvious step, but probably not a dramatic improvement? What about an SSD for this Sage/SQL Server VM (VM = 100GB, <10GB for the actual live DB) ? Can SSDs be put into the SAS hot-swap bays? Or will I have to use the mobo SATA(3Gbps?) ports, or PCI-E SSD card? Should SSDs be RAIDed for this situation? Or is SSD's higher reliability offsetting the need for RAID1/5/10? (I have nightly full disk backups) New territory for me, would appreciate some feedback. Thanks, Anthony.

    Read the article

  • Windows 7 - "A disk read error occured. Press Ctrl + Alt + Del to restart"

    - by Senthil
    Problem: When I switch on my PC, after BIOS POST, a cursor is blinking for about 5 seconds and then I am getting this error message: A disk read error occurred. Press Ctrl + Alt + Del to restart. I am able to go into BIOS. But Windows loader doesn't even start. This message is shown after my motherboard logo comes and goes. Symptoms: I DID notice my system freezing for minutes at a time for past two days. Also, in the past two days, it stopped half way through the Window booting process. I had to do hard reset couple of times to get it working. But since today morning, I only get this error message. Configuration: Operating System: Windows 7 Ultimate 32-bit only. Hard disk: 1 Physical Disk - 80GB SATA Partitions: Two (2) - C: and D: File System: NTFS No drive encryption or compression is turned on. After I searched on the net, I have found people mentioning these possible causes: Hard Disk is physically failing Corrupt MBR Bad Sector I am planning to buy a new hard disk, install Windows on it and continue. But I need data from the old hard disk. The data I want is in D: drive, outside any Windows user folder, is not encrypted or compressed or protected in anyway. I think if someone/something can get the disk working again and knows NTFS, the data can be hopefully read. What steps should I follow to recover files from the defective disk? Update: I bought a new disk, installed windows on it and added the defective one as a slave. Then I was able to read the data from the defective hard disk. Though chkdsk found lots of errors, the files I wanted were not affected and I got them back :) I am not using that hard disk anymore though it seems to be working at the moment.

    Read the article

  • Server 2003 crashing intermittently, want to transfer function to other DC

    - by user1305332
    I have a Win2003R2 server that is intermittently crashing after some virus were introduced. I'm sure all virus have been cleaned thanks to Malwarebytes (were using McAfee - useless). When it crashes you can't login (local or remote) but can still access files remotely and ping it. After a while even file sharing stops and have to kill power to restart it (no BSOD) I need to either fix it (tried to reinstall SP2 and I tried to reinstall windows in repair mode but the repair option was not available when I booted from installation disks) or move it's functionality to another DC (another 2003R2 server). The server that's crashing is old with SCSI drives while the new server uses SATA drives and faster so it seems like a good idea to just transfer roles and ditch the old box. Finding replacement SCSI drives looks expensive if they ever fail. What would I need to transfer roles. If I just move the 5 FSMO roles and copy over the file shares. Would the new server have enough to run without the old server? Never done something like this, just want some tips. Thanks.

    Read the article

  • Increasing MSSQL/Sage performance with SSD? (Dell PE T410)

    - by Anthony
    I have a client wanting better performance of their Sage (Accpac & CRM) server (v5.5, soon to be v7). It's running on 1 of 2 Hyper-V VMs (Svr2008) on a Dell PE T410 server with 24GB of RAM (1333MHz) & dual quad-core, and both VMs (only their C: drives) are on a single RAID5 array. All clients connect via 1Gb ethernet. The 2nd VM is SBS2008 with 9GB RAM (& all SBS dbs & company data are on a separate RAID5 array), & 3GB RAM for the Svr2008 hypervisor. I've given the Sage/MSSQL VM all the RAM I can (12GB) & SQL RAM caching (~8GB, never exceeds ~7.5GB, eg. entire db can now be cached in RAM) and that's helped significantly. Upgrading the Hypervisor to Svr2012 is an obvious step, but probably not a dramatic improvement? What about an SSD for this Sage/SQL VM (VM = 100GB, <10GB for the actual live DB) ? Can SSDs be put into the SAS hot-swap bays? Or will I have to use the mobo SATA(3Gbps?) ports, or PCI-E SSD card? Should SSDs be RAIDed for this situation? Or is SSD's higher reliability offsetting the need for RAID1/5/10? (I have nightly full disk backups) New territory for me, would appreciate some feedback. Thanks, Anthony.

    Read the article

  • I keep losing wireless connection

    - by posfan12
    I have a WRT54GL v1.1 wireless router and a WUSB54G v4 wireless adapter, both made by Linksys. The router is in the living room by the TV and the my computer is in the bedroom. My ISP is Brighthouse. Operating System Microsoft Windows 7 Home Premium 64-bit SP1 CPU Intel Core 2 Duo E6600 @ 2.40GHz 36 °C Conroe 65nm Technology RAM 3.00GB Single-Channel DDR2 @ 333MHz (5-4-4-14) Motherboard eMachines EMCP73VT-PM (CPU 1) 26 °C Graphics ASUS VS247 (1920x1080@60Hz) 767MB GeForce GTX 460 (nVidia) 43 °C Hard Drives 466GB Seagate ST350041 8AS SCSI Disk Device (SATA) 35 °C Optical Drives HL-DT-ST DVDRAM GH41N SCSI CdRom Device Audio High Definition Audio Device The problem is that my Internet connection will work fine for 15 minutes or so. Then the data will just stop flowing. Windows says I am still connected, and the systray icon still shows five bars. But Comodo Firewall will stop showing up and down traffic, and another of my systray applications complains about a lack of connection. What I usually do is either disconnect from the network manually, or unplug and re-plug the USB adapter. At which point the connection will work properly for another 15 minutes. I've tried unplugging my router for 30 seconds and letting it reboot. I've also tried looking for a newer driver for my adapter but I seem to have the latest version 3.1.3.0. This is a recent problem starting about a week ago. For the previous several months things were working just fine. I haven't made any changes to my system that I am aware of. The only thing I did was open my case to blow the dust out of it, then put everything back together. How do I fix this issue?

    Read the article

  • Setting up a Pagefile and Partition in Server 2008

    - by Brett Powell
    I am setting up 18 new machines for our company, and I have instructions from my new boss on setting up a Pagefile and Partition. I have looked at their existing machines to base the new setups off of, but there is no consistency between any 2 machines, which has left me extremely frustrated to say the least. My instructions are... 1) Set a static pagefile (use recommended value as max/min), set it on SSD if SSD available. 2) Make 3 partitions: C: is used for OS and install files D: is used for backups on machines with a SSD. On machines without SSD create a D: partition for pagefile (2*installed RAM for partition size) E: must be the partition hosting user files I have never messed with Pagefiles before, and looking at their existing machines is offering no help. My questions are... 1) As the machines I am setting up have no SSD (just 2 SATA drives) does it sound like the Pagefile should be setup on the C: (primary) drive or the D:? The instructions are vague so I have no idea. 2) As C: and D: are both Physical drives, does it sound like C: should be partitioned out to create the E: drive or D:? Thanks for any help I can get. I am extremely stressed out under a massive workload right now, and these vague instructions are quite infuriating.

    Read the article

  • Fedora 9 not reconizing hard drive

    - by Andrew Jones
    I am installing Fedora 9 to a PC (specifications at the bottom) and have had a lot of trouble with it recognising the hard drive. To get the Fedora installer to recognize it in the first place I had to pass "ata_generic.all_generic_ide=1 pci=nomsi" to the kernel, after which it installed OK. However, now when I boot the installed OS, I get a "could not find filesystem '/dev/root'" error. I tried passing the same arguments to the kernel at boot as I did when installing but to no avail. I have tried using the default LVM layout and defining manual ones but it made no difference. There is no option in the BIOS to enable AHCI or anything like that, in fact the BIOS is very limited in most respects. I can get into the system by using the installation CD in rescue mode (with those extra kernal parameters) but I'm not sure what to do once in there... Unfortunately using a more recent version of Fedora or even another Linux distribution altogether isn't an option becuase of outside constraints - which is annoying since I know for a fact Ubuntu works fine on this setup. I have not been using Linux that long, so treat me like an idiot - I am one. Any help would be greatly appreciated, thanks! System spec: Intel Atom Z530 CPU @ 1.6 GHz Intel US15W chipset 1 GB DDR2 160 GB SATA harddisk (Samsung HM16HI) 1000 Mbit/s Ethernet port Phoenix BIOS

    Read the article

  • New SSD freezing on older motherboard (intel G31)

    - by DJM
    I have an ECS G31T-M motherboard running a Core2 Quad processor, 4gb RAM, Windows 7 32bit, Geforce 9600GT. Bought a Sandisk Extreme III 120GB (SDSSDX-120G-G25) and installed today. I'm outputting this from my 9600GT with included TV-out adapter to Component video (to my HDTV). This motherboard is SATA 2 and from what I can tell, SSDs run on the IDE controller and there is nothing fancy to set up advanced features of SSDs. I've noticed on other forums (but not verifying with ECS) this board does not support AHCI. I have two versions of Windows 7 installed on two drives, the SSD and an old 500G disc drive. When booted from my older 500G HDD, video plays fine on the HDTV. When booting the SSD windows 7 install, I am freezing constantly, as in, video plays OK for a minute, then picture freezes for 1-3 minutes (sometimes as audio continues playing) and returns for 20-30 seconds before doing the same thing again. Other tasks such as basic maneuvering through file folders seems to be no problem. Please help!! Do I need a new system for this thing to work, or could there be other fixes? I updated firmware to R201 to no avail. DJM

    Read the article

  • I flashed my DS4700 with a 7 series firmware, now my DS4300 cannot read the disks I moved to that lo

    - by Daniel Hoeving
    In preparation for adding a number of 1Tb SATA disks to our DS4700 I flashed the controller firmware from a 6 series (which only supports up to 2Tb logical drives) to a 7 series (which supports larger than 2Tb logical drives). Attached to this DS4700 was a EXP710 expansion drawer that we had planned to migrate out to our co-location to allieviate the storage issues we were having there. Unfortunately these two projects were planned in isolation to one another so I was at the time unaware of the issue that this would cause. Prior to migrating the drawer I was reading the "IBM TotalStorage DS4000 EXP700 and EXP710 Storage Expansion EnclosuresInstallation, User’s, and Maintenance Guide" and discovered this: Controller firmware 6.xx or earlier has a different metadata (DACstore) data structure than controller firmware 7.xx.xx.xx. Metadata consists of the array and logical drive configuration data. These two metadata data structures are not interchangeable. When powered up and in Optimal state, the storage subsystem with controller firmware level 7.xx.xx.xx can convert the metadata from the drives configured in storage subsystems with controller firmware level 6.xx or earlier to controller firmware level 7.xx.xx.xx metadata data structure. However, the storage subsystem with controller firmware level 6.xx or earlier cannot read the metadata from the drives configured in storage subsystems with controller firmware level 7.xx.xx.xx or later. I had assumed that if I deleted the logical drives and array information on the EXP710 prior to migrating it to the DS4300 (6.60.22 firmware) this would satisfy the above, unfortunately I was wrong. So my question is a) Is it possible to restore the DAC information to its factory settings, b) What tool(s) would I use to accomplish this, or c) is this a lost cause? Daniel.

    Read the article

  • Dell Poweredge 1950 with Perc 5i keeps losing raid config -> "Foreign Configuration Found"

    - by nosage
    The quick and dirty: the machine is a Dell Poweredge 1950, dual xeon quad cores, 8GB of ram, 2 2TB seagate SATAs in (supposed to be raid1) using a Perc 5i raid card. They are hot-swappable with a back-plane. I can build the raid fine and after a little while an install of server 08 r2 will blue screen and restart. When it comes up the raid controller says "Foreign Configuration Found." When I go into the raid configuration panel there is no raid listed but I can import the "foreign config", and the OS will boot up fine, until it blue screens again after a little while. The issue is OS independent. I have tried swapping raid cards, swapping the RAM module on the raid card and swapping the raid battery, all to no avail. Its almost as if there is a loose connection from the raid card to the back plane and both of disks get lost and the raid card drops the config. But it sees the disks fine when it boots back up. The raid card uses a SCSI SAS cable to connect to the back-plane so I guess the next step is to replace that, but... then I might as well replace the back-plane with a SCSI SAS to sata breakout cable, but... then I need a way to power the disks. Sorry for the wall of txt but it would be great to get some thoughts from people who worked with perc raid cards or poweredge servers with this type of issue before. Ironically I want to get this system up and running so I can work on MCITP labs. Thank you for any/all help and feel free to ask questions!

    Read the article

  • Windows won't sleep after booting from grub

    - by mkasberg
    I recently added a second hard drive to my computer and I am using it do dual-boot Linux (Ubuntu 12.04) with Windows 7. Both hard drives are SATA. I am using the default grub bootloader on my second hard drive. The windows drive is unmodified. To get to grub, I changed the hard disk boot priority in my BIOS (P35-DS3L) to boot from the second drive. The problem I'm having is that when I boot to Windows 7 (on sda) from grub (on sdb), Windows 7 will not go to sleep (from the start menu). The display shuts off momentarily as if its going to sleep, then comes back on and displays the switch-user screen. Powercfg -lastwake does not show anything. I am sure that this is related to booting from grub on sdb because when I change the hard disk boot priority in the BIOS to boot from my (unmodified) Windows hard disk, the computer goes to sleep fine. It occurred to me that installing grub on sda might solve the problem, but I'd rather not since I like to have my windows hard disk unmodified so that booting to it from the BIOS boots directly to windows. A possible work around is to use the BIOS as a bootloader, by pressing F8 to select the boot device. Still, I'd like to know why the problem is happening in the first place.

    Read the article

  • Intel Rapid Storage Technology (pre-OS) driver installation

    - by Nero theZero
    My desktop machine is built on Gigabyte GA-Z87-UD3H and Gigabyte provides the latest driver for Intel Rapid Storage Technology (IRST), which I installed after installing the OS. Same goes for my Lenovo Thinkpad-T420. And for both machine, checking the controller device under the IDE ATA/ATAPI Controllers section in Device Manager I see the driver has been updated to the latest version. I set the SATA controller to AHCI from BIOS On the desktop machine I have one WD 2TB BLACK & one WD 3TB Green I don’t use RAID, & no chance of using in near future, but according to Intel IRST improves performance in single disk scenario too. Now I have the following questions – What is the actual purpose of IRST (pre-OS install) driver that doesn’t get served with a post-OS driver that I installed? There must be some difference, otherwise there wouldn’t be a pre-OS version of the driver. Right? In the pre-OS procedure (loading the drivers at OS-installation time) after successfully completing the OS installation, do I need that post-OS driver? Because after installing from that one I got a quick launch icon that runs the IRST configuration application. Where do get that after installing the pre-OS driver? As it is “pre-OS”, when I load it at OS-installation time, does it updates anything at BIOS level or anywhere other than HDD? That’s because I’m going to dual boot Windows 7 with Windows 8.1, and after installing Windows 7 when I install Windows 8.1 & load the IRST driver for that, is there any chance of any “overwriting” or OS-incompatibility? In short, is there anything specific to follow while installing the second OS?

    Read the article

  • does my machine configuration make sense?

    - by user1227914
    i couldn't think of a better place to ask this question, so here it goes. we're putting together a dedicated server for a website that will initially host the web server and the mysql database. as the website grows, we'll move the database to a different server and this machine will eventually only server the actual website. so the question is ...does my configuration look okay? it's the first time i'm building a server from scratch so i want to make sure i don't combine components that don't fit or something. things like ..do the drives i picked work for the hot swap ..etc. what do you guys think? am i good to go with this configuration? :) Chassis: Supermicro SuperServer 6016T-MTHF (6x DDR3 SDRAM - ECC DIMM 240-pin, 2x LGA1366 Socket, Power Provided: 600 Watt, 4 (free) x hot-swap - 3.5") CPU: Intel BX80614E5620 Xeon E5620 Processor - 4 Core, 2.40GHz, LGA 1366, 5.86GT/s QPI 12MB Cache, 64-Bit, 80W, HyperThreading Memory: Crucial CT51272BB1339 4GB PC10600 DDR3 Memory - 1333MHz, ECC, Registered, 1x4096MB (possibly 3 or 4 of them) Hard Drives: Western Digital WD2002FAEX Caviar Black Hard Drive - 2TB, 3.5", SATA 6Gbps, 7200 RPM, 64MB (possibly 2 or 3). thank you very much for any professional advice :)

    Read the article

  • NTBackup Error: C: is not a valid drive

    - by Chris
    I'm trying to use NtBackup to back up the C: Drive on a Microsoft Windows Small Business Server 2003 machine and get the following error in the log file: Backup Status Operation: Backup Active backup destination: 4mm DDS Media name: "Media created 04/02/2011 at 21:56" Error: The device reported an error on a request to read data from media. Error reported: Invalid command. There may be a hardware or media problem. Please check the system event log for relevant failures. Error: C: is not a valid drive, or you do not have access. The operation did not successfully complete. I'm using a brand new SATA Quantum Dat-72 drive with a brand new tape (tried a couple of tapes). I carry out the following: Open NTBackup Select Backup Tab Tick the box next to C: Ensure Destination is 4mm DDS Media is set to New Press Start Backup Choose Replace the data on the media and press Start Backup NTBackup tries to mount the media Error Message shows: The device reported an error on a request to read data from media. Error reported: INvalid command. There may be a hardware or media problem. Please check the system event log for relevant failures. On checking the log I find the following: Event Type: Information Event Source: NTBackup Event Category: None Event ID: 8018 Date: 04/02/2011 Time: 22:02:02 User: N/A Computer: SERVER Description: Begin Operation For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. and then; Event Type: Information Event Source: NTBackup Event Category: None Event ID: 8019 Date: 04/02/2011 Time: 22:02:59 User: N/A Computer: SERVER Description: End Operation: The operation was successfully completed. Consult the backup report for more details. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.

    Read the article

  • How do I install a different OS on a Compaq Presario cq56 with preinstalled SuSE 11?

    - by McCoy
    Thing is, I don't have a clue of Linux systems, I usually use WinXP. Bought a notebook with SuSE 11 on it, because I have my XP licence and thought I could install that if I found the chipset drivers for the hardware (which I'm not completely sure I have the right versions of). Then I thought I'd give it a shot with the SuSE, looked nice enough. But I can't get my external hd to work (tried force mount) and the banshee doesn't do anything like playing video. Since that is one of the two main purposes of this notebook, I need to get that to work. Tried downloading VLC player, but that only works with SuSE 11.1 upwards. So I downloaded a SuSE 11.3 and burned the iso. But surprise, no way the notebook would boot from cd. Same with the XP cd (considered setting up a dual boot). And no, I can't get to BIOS to reset to default, either. So I can basically do nothing else than going online with this thing and that's not enough for me (gamer in withdrawal, yikes!). I need at least to get to my firefox profile on the external hd and be able to watch video. Can somebody please help me? I think at this point I'd prefer to install XP and MAYBE the SuSE 11.3 after that. I'm not a native speaker, so please speak plainly, thanks. :) Edit: if this is impossible, could someone please help me with the external hd mount and video playback? Edit: Found out how to boot from cd by now. But still no XP, because I get bluescreen after bluescreen while setup is loading files. I guess it's the missing SATA drivers...

    Read the article

  • How to disable auto insert notification in Windows 7?

    - by White Phoenix
    Alright, here's the problem. My hard drive activity light on my custom built PC is blinking exactly once every second. Microsoft has this to say on the issue: http://support.microsoft.com/kb/138598 There has been discussion on this issue several months ago: Why does my hard drive LED light blink every second? The problem seems to stem from primarily Windows 7 polling the CD-ROM/DVD drive every second to see if something is inserted. The Windows 7 users in the thread that was linked in the superuser question, https://social.technet.microsoft.com/Forums/fi-FI/w7itprohardware/thread/4f6f63b3-4b58-4154-9298-1566100f9d00, have confirmed that this IS a known issue with Windows 7. Some people point at the motherboard circuitry causing the CD-ROM and SATA activity to both be linked to that hard drive activity, but whatever the case, the temporary solution seems to be to disable the CD/DVD-ROM drive in Device Manager. In fact, disabling the CD/DVD-ROM does stop the blinking, but of course this solution is counterproductive, because I shouldn't have to entirely disable a device to fix this problem. I've done the following suggestions in that thread: Change the autorun registry entry to 0 Completely disable autoplay in the autoplay control panel Disable autoplay in the Local Group Policy Editor. None of these stop the blinking from happening - apparently these solutions work for both XP and Vista, but it seems to be different in Windows 7. So I'm wondering if anyone has found out how to completely disable the polling in Windows 7, or if this will just have to be an issue we will have to deal with. There's no option to disable the auto insert notification when you go to the device within device manager (there was in XP), so I got no idea where this option is hidden, or if there's a registry key entry I could change to stop the polling. Anyone have any idea?

    Read the article

  • New XPC: No video, no ethernet link, but drive spins

    - by Mike Pennington
    I bought a Shuttle XPC SH67H3 with integrated video. I installed: An Intel i5 2450P 16GB DDR3 RAM A SATA hard drive from my old linux server that still is bootable I have both power connectors plugged into the motherboard. I realize that the Intel i5-2450P doesn't have video capabilities; however, the drive spins like it's doing something useful. It seems like I should get an ethernet link light when I fire this up. I plan to run this headless anyway, so it would be really nice if I could figure out how to run this without a video card at all. I know the IP address and login info for the linux install on the disk. I plugged in speakers, but get no bios beeps when I power it up. Shuttle's bios manual has nothing in there that indicates I should have problems in this configuration. My questions: Is there a reason that the missing video card would block usage of the ethernet port? Are there settings on the motherboard / bios I can change to get this working?

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • How do I know what hardware to buy to meet my needs?

    - by Darth Android
    While Stack Exchange does not permit shopping recommendations, it doesn't provide any general advice to consider when buying hardware. So, instead of just telling those that ask what to buy that it's not allowed, let's tell them how to figure out what they need. When looking forward to build a computer, how do I know what to buy? How do I find out if a given CPU will be enough for a certain game or application that I want to run? How do I find out if a given graphics card will be enough for a certain game or application? What is important when looking at motherboards? How much memory do I need? How do I know how much wattage I need for a power supply? What size case do I need? What relevant standards do I need to read up on and be aware of? PCI, PCIe, SATA, USB 2.0, USB 3.0, etc... What "gotchas" do I need to be on the lookout for? Please keep responses generation-agnostic to ensure they will be helpful to our future users. :)

    Read the article

  • How do I configure nVidia drivers on a Portable Ubuntu setup?

    - by Nicholas Flynt
    I've been pulling my hair out over this one for a couple of days now, google is no help. I've created a wonderful (until this issue) portable copy of Ubuntu linux that will boot on mostly anything by using a USB enclosure for my laptop's 80GB SATA drive. So far so good, it boots and runs on everything, and on non-nVidia card setups was even detecting the drivers, or letting me install the required drivers for hardware acceleration and compiz. Because you know, the wobble windows are the most awesome thing ever. Anyway, my desktop machine had an nVidia card, so I'm thinking, sure, I'll just install the nVidia drivers like before and everything will work happily. Not so-- now the desktop and any other nVidia cards work great, but it seems to have completely disabled any other graphics cards. When the kernel module detects that an nVidia card isn't present, it shoots up this nasty little dialog box giving me the option to boot into "low graphics" mode, which doesn't even allow me to use the correct screen resolution, much less see the installed graphics card and try to configure a driver for it. Is there any way to configure Ubuntu (with the dreaded nVidia kernel module) so that it can use nVidia's drivers when an nVidia card is present, and default to the normal (not low-graphics) setup in other cases, so that it has a fair chance of using what's actually present? I'm not afraid to much with config files, I just don't know the underlying system well enough to feel comfortable diving in without a push in the right direction. Thanks guys!

    Read the article

  • Dedicated server with a lot of storage and good support - and cost-effective

    - by Martin Burger
    Hello, I am from Germany and looking for a dedicated server located in the US with a lot of storage: 750 - 1500 GB. CPU speed and amount of memory are secondary, the server will host large amounts of media files via http and ftp - the basic task is to help people exchange media files. In Germany, there are some good offers, like "Root Server EQ6" at www.hetzner.de. For example, that company provides support of high quality, and their plans are very cost-effective. The plan mentioned above costs about $90 per month and provides two 1500 GB SATA-II HDDs (Software-RAID 1). In the US, I found (amongst others) Go Daddy and rackspace. Go Daddy offers some "Storage Monster" plans that include 2 x 1,000 GB hard drives for about $180 per month - already twice as much as Hetzner above. However, I found some blog and forum entries that complain about the support provided by Go Daddy. Rackspace seems to provide decent support, but they are very "upscale". Their dedicated servers are customizable and start at $419 - thus, about 4.5 times as much as Hetzner. Can anybody recommend a solution / plan that is comparable to the one by Hetzner? Or are prices for dedicated servers in general much higher than in Germany? Regards, Martin

    Read the article