Search Results

Search found 5169 results on 207 pages for 'sos dll'.

Page 45/207 | < Previous Page | 41 42 43 44 45 46 47 48 49 50 51 52  | Next Page >

  • How do I solve the .NET CF exception "Can't find PInvoke DLL"?

    - by Ignas Limanauskas
    This is to all the C# gurus. I have been banging my head on this for some time already, tried all kinds of advice on the net with no avail. The action is happening in Windows Mobile 5.0. I have a DLL named MyDll.dll. In the MyDll.h I have: extern "C" __declspec(dllexport) int MyDllFunction(int one, int two); The definition of MyDllFunction in MyDll.cpp is: int MyDllFunction(int one, int two) { return one + two; } The C# class contains the following declaration: [DllImport("MyDll.dll")] extern public static int MyDllFunction(int one, int two); In the same class I am calling MyDllFunction the following way: int res = MyDllFunction(10, 10); And this is where the bloody thing keeps giving me "Can't find PInvoke DLL 'MyDll.dll'". I have verified that I can actually do the PInvoke on system calls, such as "GetAsyncKeyState(1)", declared as: [DllImport("coredll.dll")] protected static extern short GetAsyncKeyState(int vKey); The MyDll.dll is in the same folder as the executable, and I have also tried putting it into the /Windows folder with no changes nor success. Any advice or solutions are greatly appreciated.

    Read the article

  • Need help converting a C++ header file to delphi

    - by grzegorz1
    I need help with converting c++ header file to delphi. I spent several days on this problem without success. Below is the original header file and my Delphi translation. ///////////////////////// C++ header file //////////////////////////////////// if _MSC_VER 1000 pragma once endif // _MSC_VER 1000 ifdef DVP7010BDLL_EXPORTS define DVP7010BDLL_API __declspec(dllexport) else define DVP7010BDLL_API __declspec(dllimport) endif define MAXBOARDS 4 define MAXDEVS 4 define ID_NEW_FRAME 37810 define ID_MUX0_NEW_FRAME 37800 define ID_MUX1_NEW_FRAME 37801 define ID_MUX2_NEW_FRAME 37802 define ID_MUX3_NEW_FRAME 37803 typedef enum { SUCCEEDED = 1, FAILED = 0, SDKINITFAILED = -1, PARAMERROR = -2, NODEVICES = -3, NOSAMPLE = -4, DEVICENUMERROR = -5, INPUTERROR = -6, // VERIFYHWERROR = -7 } Res; typedef enum tagAnalogVideoFormat { Video_None = 0x00000000, Video_NTSC_M = 0x00000001, Video_NTSC_M_J = 0x00000002, Video_PAL_B = 0x00000010, Video_PAL_M = 0x00000200, Video_PAL_N = 0x00000400, Video_SECAM_B = 0x00001000 } AnalogVideoFormat; typedef enum { SIZEFULLPAL=0, SIZED1, SIZEVGA, SIZEQVGA, SIZESUBQVGA } VideoSize; typedef enum { STOPPED = 1, RUNNING = 2, UNINITIALIZED = -1, UNKNOWNSTATE = -2 } CapState; class IDVP7010BDLL { public: int AdvDVP_CreateSDKInstence(void **pp); virtual int AdvDVP_InitSDK() PURE; virtual int AdvDVP_CloseSDK() PURE; virtual int AdvDVP_GetNoOfDevices(int *pNoOfDevs) PURE; virtual int AdvDVP_Start(int nDevNum, int SwitchingChans, HWND Main, HWND hwndPreview) PURE; virtual int AdvDVP_Stop(int nDevNum) PURE; virtual int AdvDVP_GetCapState(int nDevNum) PURE; virtual int AdvDVP_IsVideoPresent(int nDevNum, BOOL* VPresent) PURE; virtual int AdvDVP_GetCurFrameBuffer(int nDevNum, int VMux, long* bufSize, BYTE* buf) PURE; virtual int AdvDVP_SetNewFrameCallback(int nDevNum, int callback) PURE; virtual int AdvDVP_GetVideoFormat(int nDevNum, AnalogVideoFormat* vFormat) PURE; virtual int AdvDVP_SetVideoFormat(int nDevNum, AnalogVideoFormat vFormat) PURE; virtual int AdvDVP_GetFrameRate(int nDevNum, int *nFrameRate) PURE; virtual int AdvDVP_SetFrameRate(int nDevNum, int SwitchingChans, int nFrameRate) PURE; virtual int AdvDVP_GetResolution(int nDevNum, VideoSize *Size) PURE; virtual int AdvDVP_SetResolution(int nDevNum, VideoSize Size) PURE; virtual int AdvDVP_GetVideoInput(int nDevNum, int* input) PURE; virtual int AdvDVP_SetVideoInput(int nDevNum, int input) PURE; virtual int AdvDVP_GetBrightness(int nDevNum, int input, long *pnValue) PURE; virtual int AdvDVP_SetBrightness(int nDevNum, int input, long nValue) PURE; virtual int AdvDVP_GetContrast(int nDevNum, int input, long *pnValue) PURE; virtual int AdvDVP_SetContrast(int nDevNum, int input, long nValue) PURE; virtual int AdvDVP_GetHue(int nDevNum, int input, long *pnValue) PURE; virtual int AdvDVP_SetHue(int nDevNum, int input, long nValue) PURE; virtual int AdvDVP_GetSaturation(int nDevNum, int input, long *pnValue) PURE; virtual int AdvDVP_SetSaturation(int nDevNum, int input, long nValue) PURE; virtual int AdvDVP_GPIOGetData(int nDevNum, int DINum, BOOL* value) PURE; virtual int AdvDVP_GPIOSetData(int nDevNum, int DONum, BOOL value) PURE; }; /////////////////// delphi /////////////////////////////////////// unit IDVP7010BDLL_h; interface uses Windows, Messages, SysUtils, Classes; //{$if _MSC_VER 1000} //pragma once //{$endif} // _MSC_VER 1000 {$ifdef DVP7010BDLL_EXPORTS} //const DVP7010BDLL_API = __declspec(dllexport); {$else} //const DVP7010BDLL_API = __declspec(dllimport); {$endif} const MAXDEVS = 4; MAXMUXS = 4; ID_NEW_FRAME = 37810; ID_MUX0_NEW_FRAME = 37800; ID_MUX1_NEW_FRAME = 37801; ID_MUX2_NEW_FRAME = 37802; ID_MUX3_NEW_FRAME = 37803; // TRec SUCCEEDED = 1; FAILED = 0; SDKINITFAILED = -1; PARAMERROR = -2; NODEVICES = -3; NOSAMPLE = -4; DEVICENUMERROR = -5; INPUTERROR = -6; // TRec // TAnalogVideoFormat Video_None = $00000000; Video_NTSC_M = $00000001; Video_NTSC_M_J = $00000002; Video_PAL_B = $00000010; Video_PAL_M = $00000200; Video_PAL_N = $00000400; Video_SECAM_B = $00001000; // TAnalogVideoFormat // TCapState STOPPED = 1; RUNNING = 2; UNINITIALIZED = -1; UNKNOWNSTATE = -2; // TCapState type TCapState = Longint; TRes = Longint; TtagAnalogVideoFormat = DWORD; TAnalogVideoFormat = TtagAnalogVideoFormat; PAnalogVideoFormat = ^TAnalogVideoFormat; TVideoSize = ( SIZEFULLPAL, SIZED1, SIZEVGA, SIZEQVGA, SIZESUBQVGA); PVideoSize = ^TVideoSize; P_Pointer = ^Pointer; TIDVP7010BDLL = class function AdvDVP_CreateSDKInstence(pp: P_Pointer): integer; virtual; stdcall; abstract; function AdvDVP_InitSDK():Integer; virtual; stdcall; abstract; function AdvDVP_CloseSDK():Integer; virtual; stdcall; abstract; function AdvDVP_GetNoOfDevices(pNoOfDevs : PInteger) :Integer; virtual; stdcall; abstract; function AdvDVP_Start(nDevNum : Integer; SwitchingChans : Integer; Main : HWND; hwndPreview: HWND ) :Integer; virtual; stdcall; abstract; function AdvDVP_Stop(nDevNum : Integer ):Integer; virtual; stdcall; abstract; function AdvDVP_GetCapState(nDevNum : Integer ):Integer; virtual; stdcall; abstract; function AdvDVP_IsVideoPresent(nDevNum : Integer; VPresent : PBool) :Integer; virtual; stdcall; abstract; function AdvDVP_GetCurFrameBuffer(nDevNum : Integer; VMux : Integer; bufSize : PLongInt; buf : PByte) :Integer; virtual; stdcall; abstract; function AdvDVP_SetNewFrameCallback(nDevNum : Integer; callback : Integer ) :Integer; virtual; stdcall; abstract; function AdvDVP_GetVideoFormat(nDevNum : Integer; vFormat : PAnalogVideoFormat) :Integer; virtual; stdcall; abstract; function AdvDVP_SetVideoFormat(nDevNum : Integer; vFormat : TAnalogVideoFormat ) :Integer; virtual; stdcall; abstract; function AdvDVP_GetFrameRate(nDevNum : Integer; nFrameRate : Integer) :Integer; virtual; stdcall; abstract; function AdvDVP_SetFrameRate(nDevNum : Integer; SwitchingChans : Integer; nFrameRate : Integer) :Integer; virtual; stdcall; abstract; function AdvDVP_GetResolution(nDevNum : Integer; Size : PVideoSize) :Integer; virtual; stdcall; abstract; function AdvDVP_SetResolution(nDevNum : Integer; Size : TVideoSize ) :Integer; virtual; stdcall; abstract; function AdvDVP_GetVideoInput(nDevNum : Integer; input : PInteger) :Integer; virtual; stdcall; abstract; function AdvDVP_SetVideoInput(nDevNum : Integer; input : Integer) :Integer; virtual; stdcall; abstract; function AdvDVP_GetBrightness(nDevNum : Integer; input: Integer; pnValue : PLongInt) :Integer; virtual; stdcall; abstract; function AdvDVP_SetBrightness(nDevNum : Integer; input: Integer; nValue : LongInt) :Integer; virtual; stdcall; abstract; function AdvDVP_GetContrast(nDevNum : Integer; input: Integer; pnValue : PLongInt) :Integer; virtual; stdcall; abstract; function AdvDVP_SetContrast(nDevNum : Integer; input: Integer; nValue : LongInt) :Integer; virtual; stdcall; abstract; function AdvDVP_GetHue(nDevNum : Integer; input: Integer; pnValue : PLongInt) :Integer; virtual; stdcall; abstract; function AdvDVP_SetHue(nDevNum : Integer; input: Integer; nValue : LongInt) :Integer; virtual; stdcall; abstract; function AdvDVP_GetSaturation(nDevNum : Integer; input: Integer; pnValue : PLongInt) :Integer; virtual; stdcall; abstract; function AdvDVP_SetSaturation(nDevNum : Integer; input: Integer; nValue : LongInt) :Integer; virtual; stdcall; abstract; function AdvDVP_GPIOGetData(nDevNum : Integer; DINum:Integer; value : PBool) :Integer; virtual; stdcall; abstract; function AdvDVP_GPIOSetData(nDevNum : Integer; DONum:Integer; value : Boolean) :Integer; virtual; stdcall; abstract; end; function IDVP7010BDLL : TIDVP7010BDLL ; stdcall; implementation function IDVP7010BDLL; external 'DVP7010B.dll'; end.

    Read the article

  • Wildcard mapping in IIS 7.0 not working

    - by jmoney
    I can't seem to get the ASP.NET engine to handle ALL wildcard mapping. When I try to make a request that is supposed to be handled by the asp.net engine, i get a 404 error from the StaticFile handler Here is the content of my web.config file. You will notice that the last entry contains the wildcard mapping rules. <handlers> <clear /> <add name="LanapCaptchaHandler" path="LanapCaptcha.aspx" verb="*" type="Lanap.BotDetect.CaptchaHandler, Lanap.BotDetect" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="ScriptHandlerFactory" path="*.asmx" verb="*" type="System.Web.Script.Services.ScriptHandlerFactory, System.Web.Extensions, Version=3.5.0.0, Culture=neutral, PublicKeyToken=31BF3856AD364E35" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="ScriptHandlerFactoryAppServices" path="*_AppService.axd" verb="*" type="System.Web.Script.Services.ScriptHandlerFactory, System.Web.Extensions, Version=3.5.0.0, Culture=neutral, PublicKeyToken=31BF3856AD364E35" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="ScriptResource" path="ScriptResource.axd" verb="GET,HEAD" type="System.Web.Handlers.ScriptResourceHandler, System.Web.Extensions, Version=3.5.0.0, Culture=neutral, PublicKeyToken=31BF3856AD364E35" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="PHP5" path="*.php" verb="*" type="" modules="IsapiModule" scriptProcessor="C:\php\php5isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="bitness32" responseBufferLimit="4194304" /> <add name="rules-Integrated" path="*.rules" verb="*" type="System.ServiceModel.Activation.HttpHandler, System.ServiceModel, Version=3.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="rules-ISAPI-2.0" path="*.rules" verb="*" type="" modules="IsapiModule" scriptProcessor="C:\Windows\Microsoft.NET\Framework\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness32" responseBufferLimit="4194304" /> <add name="rules-64-ISAPI-2.0" path="*.rules" verb="*" type="" modules="IsapiModule" scriptProcessor="C:\Windows\Microsoft.NET\Framework64\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness64" responseBufferLimit="4194304" /> <add name="xoml-Integrated" path="*.xoml" verb="*" type="System.ServiceModel.Activation.HttpHandler, System.ServiceModel, Version=3.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="xoml-ISAPI-2.0" path="*.xoml" verb="*" type="" modules="IsapiModule" scriptProcessor="C:\Windows\Microsoft.NET\Framework\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness32" responseBufferLimit="4194304" /> <add name="xoml-64-ISAPI-2.0" path="*.xoml" verb="*" type="" modules="IsapiModule" scriptProcessor="C:\Windows\Microsoft.NET\Framework64\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness64" responseBufferLimit="4194304" /> <add name="svc-ISAPI-2.0-64" path="*.svc" verb="*" type="" modules="IsapiModule" scriptProcessor="%SystemRoot%\Microsoft.NET\Framework64\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness64" responseBufferLimit="4194304" /> <add name="svc-ISAPI-2.0" path="*.svc" verb="*" type="" modules="IsapiModule" scriptProcessor="%SystemRoot%\Microsoft.NET\Framework\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness32" responseBufferLimit="4194304" /> <add name="svc-Integrated" path="*.svc" verb="*" type="System.ServiceModel.Activation.HttpHandler, System.ServiceModel, Version=3.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="ASPClassic" path="*.asp" verb="GET,HEAD,POST" type="" modules="IsapiModule" scriptProcessor="%windir%\system32\inetsrv\asp.dll" resourceType="File" requireAccess="Script" allowPathInfo="false" preCondition="" responseBufferLimit="4194304" /> <add name="SecurityCertificate" path="*.cer" verb="GET,HEAD,POST" type="" modules="IsapiModule" scriptProcessor="%windir%\system32\inetsrv\asp.dll" resourceType="File" requireAccess="Script" allowPathInfo="false" preCondition="" responseBufferLimit="4194304" /> <add name="ISAPI-dll" path="*.dll" verb="*" type="" modules="IsapiModule" scriptProcessor="" resourceType="File" requireAccess="Execute" allowPathInfo="true" preCondition="" responseBufferLimit="4194304" /> <add name="TraceHandler-Integrated" path="trace.axd" verb="GET,HEAD,POST,DEBUG" type="System.Web.Handlers.TraceHandler" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="WebAdminHandler-Integrated" path="WebAdmin.axd" verb="GET,DEBUG" type="System.Web.Handlers.WebAdminHandler" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="AssemblyResourceLoader-Integrated" path="WebResource.axd" verb="GET,DEBUG" type="System.Web.Handlers.AssemblyResourceLoader" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="PageHandlerFactory-Integrated" path="*.aspx" verb="GET,HEAD,POST,DEBUG" type="System.Web.UI.PageHandlerFactory" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="SimpleHandlerFactory-Integrated" path="*.ashx" verb="GET,HEAD,POST,DEBUG" type="System.Web.UI.SimpleHandlerFactory" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="HttpRemotingHandlerFactory-rem-Integrated" path="*.rem" verb="GET,HEAD,POST,DEBUG" type="System.Runtime.Remoting.Channels.Http.HttpRemotingHandlerFactory, System.Runtime.Remoting, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="HttpRemotingHandlerFactory-soap-Integrated" path="*.soap" verb="GET,HEAD,POST,DEBUG" type="System.Runtime.Remoting.Channels.Http.HttpRemotingHandlerFactory, System.Runtime.Remoting, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" modules="ManagedPipelineHandler" scriptProcessor="" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="integratedMode" responseBufferLimit="4194304" /> <add name="AXD-ISAPI-2.0-64" path="*.axd" verb="GET,HEAD,POST,DEBUG" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework64\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness64" responseBufferLimit="0" /> <add name="PageHandlerFactory-ISAPI-2.0-64" path="*.aspx" verb="GET,HEAD,POST,DEBUG" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework64\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness64" responseBufferLimit="0" /> <add name="SimpleHandlerFactory-ISAPI-2.0-64" path="*.ashx" verb="GET,HEAD,POST,DEBUG" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework64\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness64" responseBufferLimit="0" /> <add name="WebServiceHandlerFactory-ISAPI-2.0-64" path="*.asmx" verb="GET,HEAD,POST,DEBUG" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework64\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness64" responseBufferLimit="0" /> <add name="HttpRemotingHandlerFactory-rem-ISAPI-2.0-64" path="*.rem" verb="GET,HEAD,POST,DEBUG" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework64\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness64" responseBufferLimit="0" /> <add name="HttpRemotingHandlerFactory-soap-ISAPI-2.0-64" path="*.soap" verb="GET,HEAD,POST,DEBUG" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework64\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness64" responseBufferLimit="0" /> <add name="AXD-ISAPI-2.0" path="*.axd" verb="GET,HEAD,POST,DEBUG" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness32" responseBufferLimit="0" /> <add name="PageHandlerFactory-ISAPI-2.0" path="*.aspx" verb="GET,HEAD,POST,DEBUG" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness32" responseBufferLimit="0" /> <add name="SimpleHandlerFactory-ISAPI-2.0" path="*.ashx" verb="GET,HEAD,POST,DEBUG" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness32" responseBufferLimit="0" /> <add name="WebServiceHandlerFactory-ISAPI-2.0" path="*.asmx" verb="GET,HEAD,POST,DEBUG" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness32" responseBufferLimit="0" /> <add name="HttpRemotingHandlerFactory-rem-ISAPI-2.0" path="*.rem" verb="GET,HEAD,POST,DEBUG" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness32" responseBufferLimit="0" /> <add name="HttpRemotingHandlerFactory-soap-ISAPI-2.0" path="*.soap" verb="GET,HEAD,POST,DEBUG" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="Script" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness32" responseBufferLimit="0" /> <add name="CGI-exe" path="*.exe" verb="*" type="" modules="CgiModule" scriptProcessor="" resourceType="File" requireAccess="Execute" allowPathInfo="true" preCondition="" responseBufferLimit="4194304" /> <add name="TRACEVerbHandler" path="*" verb="TRACE" type="" modules="ProtocolSupportModule" scriptProcessor="" resourceType="Unspecified" requireAccess="None" allowPathInfo="false" preCondition="" responseBufferLimit="4194304" /> <add name="OPTIONSVerbHandler" path="*" verb="OPTIONS" type="" modules="ProtocolSupportModule" scriptProcessor="" resourceType="Unspecified" requireAccess="None" allowPathInfo="false" preCondition="" responseBufferLimit="4194304" /> <add name="StaticFile" path="*" verb="*" type="" modules="StaticFileModule,DefaultDocumentModule,DirectoryListingModule" scriptProcessor="" resourceType="Either" requireAccess="Read" allowPathInfo="false" preCondition="" responseBufferLimit="4194304" /> <add name="WILDCARD MAPPING 32 BIT" path="*" verb="*" type="" modules="IsapiModule" scriptProcessor="%windir%\Microsoft.NET\Framework\v2.0.50727\aspnet_isapi.dll" resourceType="Unspecified" requireAccess="None" allowPathInfo="false" preCondition="classicMode,runtimeVersionv2.0,bitness32" responseBufferLimit="4194304" /> </handlers>

    Read the article

  • Strong Signing, and Updating A Referencing Assembly

    - by Alan
    Hi, I have two, third party assemblies: Foo.dll and ReferencesFoo.dll As noted, ReferencesFoo.dll is an assembly that has a reference to Foo.dll For my application, I need to resign these assemblies. I use ildasm/ilasm in combination along with a signing key to resign them, however, ReferencesFoo.dll still contains (in it's manifest?) the reference to the Foo.dll old public key and public key token. So, how do I sign both dll's with my key, and update the references in ReferencesFoo.dll without getting the source code and recompiling?

    Read the article

  • Why are those modules being loaded in an ASP.NET project (not website)

    - by petergmagid
    I have an ASP.NET 3.5 Project (not website) and I don't understand why all these modules are being created and loaded. I thought that with a web project it would all compile to a single .DLL 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_fwtnlvuq.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_vb8hmtmg.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_v-nkuwgl.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_wn_uucrw.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_ngd_8nhu.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_8keebrhe.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_ohg9e50r.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_yhmgvhum.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_4qltywkk.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_1nml5ezc.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_cdju8bdk.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_xhugloto.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_rkqqzc0u.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_-vfyn7ik.dll', Symbols loaded. 'WebDev.WebServer.EXE' (Managed): Loaded 'C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\reviewstat_20\c147e006\64781866\App_Web_cthyzgij.dll', Symbols loaded.

    Read the article

  • How can i use a C# dll in a Win32 C++ project ?

    - by Agito
    I am working on a solution, most of its core engine is developed as Win32 C++ (and is Platform independent and is also used on OS X), some time ago we needed to call C++ dll's of core engine from C# and I was able to Load main solution's DLL in C# (by the help of some threads here on SO). but now we have certain things implemented in Managed C# dll and need to use it in Win32 C++ project? (and just function definitions and dll are provided)

    Read the article

  • How can i Import a Managed C# dll into a Win32 C++ project ?

    - by Agito
    I am working on a solution, most of its core engine is developed as Win32 C++ (and is Platform independent and is also used on OS X), some time ago we needed to call C++ dll's of core engine from C# and I was able to Load main solution's DLL in C# (by the help of some threads here on SO). but now we have certain things implemented in Managed C# dll and need to use it in Win32 C++ project? (and just function definitions and dll are provided)

    Read the article

  • why winform using external dll(VC) and ocx(VC) control can only import one?

    - by jack
    we have a .net framework application with a vc dll and a vc ocx, and now if we only import one dll ,it is ok, but when we import both, it will pop a messagebox saying: Debug Assertion Failed! and i studied the child module of our application that import the vc dll, i found after the framework import vc ocx and initialize , then the function LoadLibrary in our module importing the vc dll would return 0, that means memory limited or call improperly, i use getlasterror() the error code is 1114. so it is very frustrated ,hope someone can help me.

    Read the article

  • Programmatically add an ISAPI extension dll in IIS 7 using ADSI?

    - by fretje
    I apologize beforehand, this is a cross post of this SO question. I thought I'd ask it there first, but apparently it doesn't harvest any answers there. I hope it will get more attention here. When I have an answer somewhere, I'll delete the other one. I'm trying to programmatically add an ISAPI extension dll in IIS using ADSI. This has been working for ages on previous versions of IIS, but it seems to fail on IIS 7. I am using similar code like shown in this question: var web = GetObject("IIS://localhost/W3SVC/1/ROOT/specificVirtualDirectory"); var maps = web.ScriptMaps.toArray(); map[maps.length] = ".aaa,c:\\path\\to\\isapi\\extension.dll,1,GET,POST"; web.ScriptMaps = maps.asDictionary(); web.SetInfo(); After executing that code, I do see an "AboMapperCustom-12345678" entry for that specific dll in the "Handler mappings" of the specific virtual directory in which I added the script map. But when I try to use that extension in a browser, I always get HTTP Error 404.2 Not Found The page you are requesting cannot be served because of the ISAPI and CGI Restriction list settings on the Web server. Even after adding an entry to allow that specific dll in the "ISAPI and CGI restrictions", I keep getting that error. To make it actually work, I first have to undo these steps (encountering the same issue like the OP of the question mentioned above: after deleting the script map entry from the IIS manager GUI, I also have to programmatically delete it using ADSI before it's actually gone from the metabase). And then manually add an entry like this: inetmgr - webserver - website - virtual directory - handler mappings - add script map... path = *.dll, executable = <path to dll>, name = <doesn't matter, but it's mandatory> click "yes" on the question "do you want to allow this ISAPI extension?" When I compare the 2 entries, they are exactly the same, except for the "Entry Type" which seems to be "Inherited" for the programmatically added one and "Local" for the one added manually. The strange thing is, even though it says "Inherited", I don't see it anywhere in IIS on a higher level. Where is it inheriting from? In my code, I do add the script map to the specific virtual directory so it should be "Local" as well. Maybe there is the problem, but I don't know how to add a "Local" Script Map using ADSI. I really would like to keep using the ADSI method, as otherwise I will have to use different methods in our setup when working with IIS 7 or previous versions, and I would like to avoid that. To recap: How can I programmatically add a script map entry and its companion CGI and ISAPI restrictions entry to IIS 7 using ADSI? Anybody who can shed some light on this? Any help appreciated.

    Read the article

  • PHP Warning: PHP Startup: Unable to load dynamic library php_mysql.dll, Mac 10.6, Apache 2.2, php 5

    - by munchybunch
    I'm trying to use the PHP CLI, and when I enter something like php test.php in the command line it returns: PHP Warning: PHP Startup: Unable to load dynamic library '/usr/lib/php/extensions/no-debug-non-zts-20090626/php_mysql.dll' - dlopen(/usr/lib/php/extensions/no-debug-non-zts-20090626/php_mysql.dll, 9): image not found in Unknown on line 0 something test.php contains: <?php echo 'something'; ?> I checked /usr/lib/php/extensions/no-debug-non-zts-20090626/, and as expected the .dll file isn't there. I'm a complete beginner when it comes to this - what is happening, and how can I fix it? A search of my system for "php_msyql.dll" reveals nothing. Does it have to do with how I compiled it? I don't have the original version of php that came with the mac, I think - I may have reinstalled it somewhere along the way. Any help would be appreciated!

    Read the article

  • How to update a keyboard layout DLL on Windows?

    - by user87690
    Information about keyboard layout is stored in keyboard layout DLLs on Windows. One can make a custom layout using a tool like Microsoft Keyboard Layout Creator (http://msdn.microsoft.com/en-us/goglobal/bb964665.aspx). It creates the dynamical library and also an installer which places the DLL at a right place and also puts necessary information to registry so the layout can be used. Now my question. How can one update his custom layout? One could uninstall the layout and install the new version which effectively replaces the DLL file. However this alone doesn't work because it seems that the old copy of the DLL stays loaded somewhere and is used when one sets the layout instead of loading new version. So is there a way how to tell the system that its “keyboard layout cache” is invalid? Of course I could reboot the whole system but I'd like to avoid it as it's annoying and seems to be poor design to reboot whole system just to reload a DLL.

    Read the article

  • N-Tier Architecture - Structure with multiple projects in VB.NET

    - by focus.nz
    I would like some advice on the best approach to use in the following situation... I will have a Windows Application and a Web Application (presentation layers), these will both access a common business layer. The business layer will look at a configuration file to find the name of the dll (data layer) which it will create a reference to at runtime (is this the best approach?). The reason for creating the reference at runtime to the data access layer is because the application will interface with a different 3rd party accounting system depending on what the client is using. So I would have a separate data access layer to support each accounting system. These could be separate setup projects, each client would use one or the other, they wouldn't need to switch between the two. Projects: MyCompany.Common.dll - Contains interfaces, all other projects have a reference to this one. MyCompany.Windows.dll - Windows Forms Project, references MyCompany.Business.dll MyCompany.Web.dll - Website project, references MyCompany.Business.dll MyCompany.Busniess.dll - Business Layer, references MyCompany.Data.* (at runtime) MyCompany.Data.AccountingSys1.dll - Data layer for accounting system 1 MyCompany.Data.AccountingSys2.dll - Data layer for accounting system 2 The project MyCompany.Common.dll would contain all the interfaces, each other project would have a reference to this one. Public Interface ICompany ReadOnly Property Id() as Integer Property Name() as String Sub Save() End Interface Public Interface ICompanyFactory Function CreateCompany() as ICompany End Interface The project MyCompany.Data.AccountingSys1.dll and MyCompany.Data.AccountingSys2.dll would contain the classes like the following: Public Class Company Implements ICompany Protected _id As Integer Protected _name As String Public ReadOnly Property Id As Integer Implements MyCompany.Common.ICompany.Id Get Return _id End Get End Property Public Property Name As String Implements MyCompany.Common.ICompany.Name Get Return _name End Get Set(ByVal value as String) _name = value End Set End Property Public Sub Save() Implements MyCompany.Common.ICompany.Save Throw New NotImplementedException() End Sub End Class Public Class CompanyFactory Implements ICompanyFactory Public Function CreateCompany() As ICompany Implements MyCompany.Common.ICompanyFactory.CreateCompany Return New Company() End Function End Class The project MyCompany.Business.dll would provide the business rules and retrieve data form the data layer: Public Class Companies Public Shared Function CreateCompany() As ICompany Dim factory as New MyCompany.Data.CompanyFactory Return factory.CreateCompany() End Function End Class Any opinions/suggestions would be greatly appreciated.

    Read the article

  • Locate modules by stack address

    - by PaulH
    I have a Winodws Mobile 6.1 application running on an ARMV4I processor. Given a stack address (from unwinding an exception), I like to determine what module owns that address. Using the ToolHelpAPI, I'm able to determine most modules using the following method: HANDLE snapshot = ::CreateToolhelp32Snapshot( TH32CS_SNAPMODULE | TH32CS_GETALLMODS, 0 ); if( INVALID_HANDLE_VALUE != snapshot ) { MODULEENTRY32 mod = { 0 }; mod.dwSize = sizeof( mod ); if( ::Module32First( snapshot, &mod ) ) { do { if( stack_address > (DWORD)mod.modBaseAddr && stack_address < (DWORD)( mod.modBaseAddr + mod.modBaseSize ) ) { // Found the module! // offset = stack_address - mod.modBaseAddr break; } } while( ::Module32Next( snapshot, &mod ) ); } ::CloseToolhelp32Snapshot( snapshot ); } But, I don't always seem to be able to find a module that matches an address. For example: stack address module offset 0x03f65bd8 coredll.dll + 0x0001bbd8 0x785cab1c mylib.dll + 0x0002ab1c 0x785ca9e8 mylib.dll + 0x0002a9e8 0x785ca0a0 mylib.dll + 0x0002a0a0 0x785c8144 mylib.dll + 0x00028144 0x3001d95c ??? 0x3001dd44 ??? 0x3001db90 ??? 0x03f88030 coredll.dll + 0x0003e030 0x03f8e46c coredll.dll + 0x0004446c 0x801087c4 ??? 0x801367b4 ??? 0x8010ce78 ??? 0x801086dc ??? 0x03f8e588 coredll.dll + 0x00044588 0x785a56a4 mylib.dll + 0x000056a4 0x785bdd60 mylib.dll + 0x0001dd60 0x785bbd0c mylib.dll + 0x0001bd0c 0x785bdb38 mylib.dll + 0x0001db38 0x3001db20 ??? 0x3001dc40 ??? 0x3001a8a4 ??? 0x3001a79c ??? 0x03f67348 coredll.dll + 0x0001d348 Where do I find those stack addresses that are missing? Any suggestions? Thanks, PaulH

    Read the article

  • 32 bit dllimport generating incorrect format error (0x8007000b) on win7 x64 platform

    - by DFP
    Hello, I'm trying to install and run a 32 bit application on a Win7 x64 machine. The application is built as a Win32 app. It runs fine on 32 bit platforms. On the x64 machine it installs correctly in the Programs(x86) directory and runs fine until I make a call into a 32 bit dll. At that time I get the incorrect format error (0x8007000b) indicating it is trying to load the dll of the wrong bitness. Indeed it is trying to load the 64 bit dll from the System32 directory rather than the 32 bit version in the SystemWOW64 directory. Another 32 bit application provided by the dll vendor runs correctly and it does load the 32 bit dll from the SystemWOW64 directory. I do not have source to their application to see how they are accessing the DLL. I'm using the DllImport function as shown below to access the dll. Is there a way to decorate the DllImport calls to force it to load the 32 bit version? Any thoughts appreciated. Thanks, DP public static class Micronas { [DllImport(@"UAC2.DLL")] public static extern short UacBuildDeviceList(uint uFlags); [DllImport(@"UAC2.DLL")] public static extern short UacGetNumberOfDevices(); [DllImport(@"UAC2.DLL")] public static extern uint UacGetFirstDevice(); [DllImport(@"UAC2.DLL")] public static extern uint UacGetNextDevice(uint handle); [DllImport(@"UAC2.DLL")] public static extern uint UacSetXDFP(uint handle, short adr, uint data); [DllImport(@"UAC2.DLL")] public unsafe static extern uint UacGetXDFP(uint handle, short adr, IntPtr data); }

    Read the article

  • C# debugging issue: No symbols are loaded for any call stack frame.

    - by Ciaran Bruen
    Hi - I'm trying to step into a method referenced in an external dll from a C# web service dll. I'm developing the web service code and can step into it from my Winforms app. The dll I'm trying to step into from the web service was developed by someone else, and I have the dll and pdb files. When I try to step into it I'm getting the message below: 'No symbols are loaded for any call stack frame. The source code cannot be displayed'. Here is my project setup: .NET 3.5, VS 2008 Professional, IIS 7 running on Vista Ultimate Winforms app WF1.exe, referencing web service dll WS1.dll, in 1 solution on my machine Database access dll DA1.dll compiled by another developer, referenced by WS1.dll DA1.dll and DA1.pdb files located in root directory of WS1 web service project WS1 web service compiled and published to my local IIS, DA1.dll and DA1.pdb files get copied to the IIS WS1 bin directory So far so good and everything works to a point. I break and step into WF1.exe then break and step into a method on WS1.dll no problems. However when I try to step into a method on DA1.dll the error occurs. Any help appreciated. Cheers, Ciaran

    Read the article

  • Crash using WscRegisterForChanges.

    - by user335126
    I'm trying to use the WscRegisterForChanges with C++ function in Windows 7. Documentation located here: http://msdn.microsoft.com/en-us/library/bb432507(v=VS.85).aspx My problem is that even though the callback properly executes, the code crashes when it gets to the end of the callback's execution. Here's the code in question. It's very simple, so I'm not sure why it's crashing: #include #include #include void SecurityCenterChangeOccurred(void *param) { printf("Change occurred!\n"); } int main() { HRESULT result = S_OK; HANDLE callbackRegistration = NULL; result = WscRegisterForChanges( NULL, &callbackRegistration, (LPTHREAD_START_ROUTINE)SecurityCenterChangeOccurred, NULL); while(1) { Sleep(100); } return 0; } My call stack looks like this when the crash occurs: 00faf6e8() ntdll.dll!_TppWorkerThread@4() + 0x1293 bytes kernel32.dll!@BaseThreadInitThunk@12() + 0x12 bytes ntdll.dll!___RtlUserThreadStart@8() + 0x27 bytes ntdll.dll!__RtlUserThreadStart@8() + 0x1b bytes If I add ExitThread(0); to the end of SecurityCenterChangeOccurred, I get an error and the following trace (So I don't think I should be using ExitThread): Unhandled exception at 0x7799852b (ntdll.dll) in WscRegisterForChangesCrash.exe: 0xC000071C: An invalid thread, handle %p, is specified for this operation. Possibly, a threadpool worker thread was specified. ntdll.dll!_TpCheckTerminateWorker@4() + 0x3ca2f bytes ntdll.dll!_RtlExitUserThread@4() + 0x30 bytes WscRegisterForChangesCrash.exe!SecurityCenterChangeOccurred(void * param=0x00000000) Line 8 + 0xa bytes C++ wscapi.dll!WorkItemWrapper() + 0x19 bytes ntdll.dll!_RtlpTpWorkCallback@8() + 0xdf bytes ntdll.dll!_TppWorkerThread@4() + 0x1293 bytes kernel32.dll!@BaseThreadInitThunk@12() + 0x12 bytes ntdll.dll!___RtlUserThreadStart@8() + 0x27 bytes ntdll.dll!__RtlUserThreadStart@8() + 0x1b bytes Does anyone have any ideas why this might be happening? To trigger the crash run the program and turn the firewall on or off.

    Read the article

  • How to diagnose cause, fix, or work around Adobe ActiveX / COM related error 0x80004005 progmaticall

    - by Streamline
    I've built a C# .NET app that uses the Adobe ActiveX control to display a PDF. It relies on a couple DLLs that get shipped with the application. These DLLs interact with the locally installed Adobe Acrobat or Adobe Acrobat Reader installed on the machine. This app is being used by some customer already and works great for nearly all users ( I check to see that the local machine is running at least version 9 of either Acrobat or Reader already ). I've found 3 cases where the app returns the error message "Error HRESULT E_FAIL has been returned from a call to a COM component" when trying to load (when the activex control is loading). I've checked one of these user's machines and he has Acrobat 9 installed and is using it frequently with no problems. It does appear that Acrobat 7 and 8 were installed at one time since there are entries for them in the registry along with Acrobat 9. I can't reproduce this problem locally, so I am not sure exactly which direction to go. The error at the top of the stacktrace is: System.Runtime.InteropServices.COMException (0x80004005): Error HRESULT E_FAIL has been returned from a call to a COM component. Some research into this error indicates it is a registry problem. Does anyone have a clue as to how to fix or work around this problem, or determine how to get to the core root of the problem? The full content of the error message is this: System.Runtime.InteropServices.COMException (0x80004005): Error HRESULT E_FAIL has been returned from a call to a COM component.    at System.Windows.Forms.UnsafeNativeMethods.CoCreateInstance(Guid& clsid, Object punkOuter, Int32 context, Guid& iid)    at System.Windows.Forms.AxHost.CreateWithoutLicense(Guid clsid)    at System.Windows.Forms.AxHost.CreateWithLicense(String license, Guid clsid)    at System.Windows.Forms.AxHost.CreateInstanceCore(Guid clsid)    at System.Windows.Forms.AxHost.CreateInstance()    at System.Windows.Forms.AxHost.GetOcxCreate()    at System.Windows.Forms.AxHost.TransitionUpTo(Int32 state)    at System.Windows.Forms.AxHost.CreateHandle()    at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible)    at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible)    at System.Windows.Forms.AxHost.EndInit()    at AcrobatChecker.Viewer.InitializeComponent()    at AcrobatChecker.Viewer..ctor()    at AcrobatChecker.Form1.btnViewer_Click(Object sender, EventArgs e)    at System.Windows.Forms.Control.OnClick(EventArgs e)    at System.Windows.Forms.Button.OnClick(EventArgs e)    at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent)    at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks)    at System.Windows.Forms.Control.WndProc(Message& m)    at System.Windows.Forms.ButtonBase.WndProc(Message& m)    at System.Windows.Forms.Button.WndProc(Message& m)    at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)    at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)    at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)

    Read the article

  • asp.net mvc paging with MvcPaging dll

    - by kusanagi
    i using MvcPaging. it work perfect, but when i call page like methodName/?param1=param1 MvcPaging not render this parameter in page numbers. for example i get urls like Consalting?pageId=0&CategoryID=&sort=&myType=&search=&StatusID= without param1=param1 how can i add this parameter?

    Read the article

  • Load ActiveX DLL in Internet Explorer with elevated privileges

    - by adum
    I have an ActiveX control that I'm loading with JavaScript in Internet Explorer. It needs to run as medium integrity under UAC in Vista and Win7. This is written in C/C++, compiled in Visual Studio. One way to elevate privileges is to create a broker process that can request a medium integrity level. However, for this project, this is not a practical solution. I really need the ActiveX control itself to run elevated. My question is: what's the easiest way to do this? Can I change the build options on the project to be an exe, and use the COM interprocess connect system to automatically handle the communications, or do I need to be more sophisticated? Do I need to do anything complicated like manually call CreateProcess and make some kind of broker, or can it just work as an ActiveX exe that elevates itself?

    Read the article

  • Using ILDASM with Visual Studio 2008

    - by pianoman
    I just installed Visual Studio 2008, and am looking to use the Microsoft Intermediate Language Disassembler (ILDASM.exe) to look at some DLLs. Problem is, "ildasm" is not recognized on the command line, and I cannot find ildasm.exe anywhere in my VS 2008 install directory (e.g. c:\programs\Visual_Studio_9.0\). Any ideas? UPDATE: Found it! At C:\Program Files\Microsoft SDKs\Windows\v6.0A\bin This answer helped.

    Read the article

< Previous Page | 41 42 43 44 45 46 47 48 49 50 51 52  | Next Page >