Search Results

Search found 5221 results on 209 pages for 'low latency'.

Page 46/209 | < Previous Page | 42 43 44 45 46 47 48 49 50 51 52 53  | Next Page >

  • Does any Certificate Authority support both SAN and wildcards?

    - by nicholas a. evans
    My basic quandry is that wildcard certificates don't support subdomains of subdomains, nor do they help with alternate domain names. Basically, if my CN is example.com, I want a Subject Alternative Name field that looks roughly like so: DNS:example.com DNS*.example.com DNS:*.beta.example.com DNS:example.net DNS:*.example.net DNS:*.beta.example.net Using a self-signed cert, I verified that the browsers will work just fine with this. Unfortunately, none of the Certificate Authorities that I looked into (Thawte, GoDaddy, Verisign, Digicert) seemed to support both wildcard certs and Subject Alternative Name (sometimes referred to as "Multiple Domain UCC"). I even called up GoDaddy tech support to confirm. Is there a CA (trusted by 99% of browsers) that supports wildcards for the Subject Alternative Name? One little restriction: I'm saddled with Amazon EC2's single Elastic IP per instance limitation. Here are what I see as my backup plans: set up three extra EC2 instances, each configured for a different IP address and cert, and nginx reverse proxy from three of them into the app server(s) introduces latency(?), and even the cheapest EC2 instance isn't that cheap instead of dedicated reverse proxy instances, setup the four or more almost identical EC2 app servers, with nginx using the port to determine which cert to deliver, and use haproxy to distribute the traffic amongst themselves. complicated to configure and manage? I'm not using the cheapest EC2 instance type for my app servers. If I don't need 4+ app servers for the load, it raises the cost. set up an external server (outside of EC2) that doesn't have EC2's Elastic IP address restrictions, setup all of the alternate IP addresses and certificates on that server, and nginx reverse proxy from that server into the EC2 app servers. extra IP addresses are almost free (still need to pay for the server of course), but don't come with the robust "elasticity" that Amazon's Elastic IPs provide. even more latency than in the first scenario. Are these approaches crazy or reasonable? Do you have another one to suggest?

    Read the article

  • Problem setting command-line console resolution. vbeinfo in grub2 does not report all resolutions

    - by Kent
    I have a Asus EEE PC 1005P which I installed a Command-line system on using the Alternate Installer CD of Ubuntu Lucid Lynx. Altough I think this is a general linux and grub2 question. I do not have (or want) the X Window System installed. I want to change my console screen resolution (not inside X) to 1024x600. But it isn't reported when I use vbeinfo inside grub: grub> vbeinfo VBE info: version: 3.0 OEM software rev: 1.0 total memory: 8128 KiB List of compatible video modes: Legend: P=Packed pixel, D=Direct color, mask/pos=R/G/B/reserved 0x112: 640 x 480 x 32 Direct, mask: 8/8/8/8 pos: 16/8/0/24 0x114: 800 x 600 x 16 Direct, mask: 5/6/5/0 pos: 11/5/0/0 0x115: 800 x 600 x 32 Direct, mask: 8/8/8/8 pos: 16/8/0/24 0x101: 640 x 480 x 8 Packed 0x103: 800 x 600 x 8 Packed 0x111: 640 x 480 x 16 Direct, mask: 5/6/5/0 pos: 11/5/0/0 Configured VBE mode (vbe_mode) = ox101 grub> Relevant parts of sudo lspci -v: ... ... 00:02.0 VGA compatible controller: Intel Corporation N10 Family Integrated Graphics Controller Subsystem: ASUSTeK Computer Inc. Device 83ac Flags: bus master, fast devsel, latency 0, IRQ 28 ... Kernel driver in use: i915 Kernel modules: i915 00:02.1 Display controller: Intel Corporation N10 Family Integrated Graphics Controller Subsystem: ASUSTeK Computer Inc. Device 83ac Flags: bus master, fast devsel, latency 0, IRQ 28 ... ... ... Any ideas on how I can set the console resultion like I want it?

    Read the article

  • different nmap results

    - by aasasas
    Hello I have a scan on my server form outside and from inside, why results are different? [root@xxx ~]# nmap -sV -p 0-65535 localhost Starting Nmap 5.51 ( http://nmap.org ) at 2011-02-16 07:59 MSK Nmap scan report for localhost (127.0.0.1) Host is up (0.000015s latency). rDNS record for 127.0.0.1: localhost.localdomain Not shown: 65534 closed ports PORT STATE SERVICE VERSION 22/tcp open ssh OpenSSH 4.3 (protocol 2.0) 80/tcp open http Apache httpd 2.2.3 ((CentOS)) Service detection performed. Please report any incorrect results at http://nmap.org/submit/ . Nmap done: 1 IP address (1 host up) scanned in 7.99 seconds AND sh-3.2# nmap -sV -p 0-65535 xxx.com Starting Nmap 5.51 ( http://nmap.org ) at 2011-02-16 00:01 EST Warning: Unable to open interface vmnet1 -- skipping it. Warning: Unable to open interface vmnet8 -- skipping it. Stats: 0:07:49 elapsed; 0 hosts completed (1 up), 1 undergoing SYN Stealth Scan SYN Stealth Scan Timing: About 36.92% done; ETC: 00:22 (0:13:21 remaining) Stats: 0:22:05 elapsed; 0 hosts completed (1 up), 1 undergoing Service Scan Service scan Timing: About 75.00% done; ETC: 00:23 (0:00:02 remaining) Nmap scan report for xxx.com (x.x.x.x) Host is up (0.22s latency). Not shown: 65528 closed ports PORT STATE SERVICE VERSION 21/tcp open tcpwrapped 22/tcp open ssh OpenSSH 4.3 (protocol 2.0) 25/tcp open tcpwrapped 80/tcp open http Apache httpd 2.2.3 ((CentOS)) 110/tcp open tcpwrapped 143/tcp open tcpwrapped 443/tcp open tcpwrapped 8080/tcp open http-proxy?

    Read the article

  • Rails/Mongo across multiple different geo-regions

    - by wmarbut
    I have a system that by necessity requires physical presence in three or more different locations and I need advice on structuring in such a way that my database stays replicated in a timely manner without horrible latency. I've seen mysql access and replication be incredibly slow when the application server was trying to talk to a node that wasn't physically collocated. In this case I am using mongodb. The stack is linux/passenger/ruby/rails/mongodb. The database is write heavy and read light. The infrastructure is Amazon EC2 The application layer must be physically located in 3 or more different locations. I can't justify this requirement further than it is a requirement. The database, however needn't be located in more than one location if it can be written to quickly from other locations. From reading mongo's documentation, mongo replication seems like more of a candidate than sharding b/c my datastore is not huge. However I don't see anything that addresses the issue of speed for servers communicating across large distances with potentially high latency.

    Read the article

  • Filtered Router Interface

    - by jviotti
    I'm having some problems with a Scientific-Atlanta DPR2320R2. In specific with the WIFI. A few months ago I changed its password and username and now I can't remember. So I tried cracking it with Hydra but it drove things worse. Content of webadmin was rendered partial, and threw lot of errors. I then reseted the router. I found myself abled to browse the web with ethernet-connected pc. Wifi is configured by registering the device's MAC Address, and indeed the router has been reseted and register MAC address were lost. No device could connect to wifi. In fact, the device does not even recognize the network. I tried the pointing to 192.168.0.1 to restablish the MAC's. But I couldn't connect to the router access point. Tried listing up hosts: $ nmap -sP 192.168.0.0/24 Starting Nmap 5.00 ( http://nmap.org ) at 2012-12-11 01:18 ART Host 192.168.0.1 is up (0.0018s latency). Host 192.168.0.11 is up (0.00025s latency). Nmap done: 256 IP addresses (2 hosts up) scanned in 59.62 seconds Then checked 192.168.0.1 was really up by sending pings. It responded to all my pings. I quick-scanned the access point: $ nmap 192.168.0.1 Starting Nmap 5.00 ( http://nmap.org ) at 2012-12-11 01:08 ART Interesting ports on 192.168.0.1: Not shown: 999 closed ports PORT STATE SERVICE 80/tcp filtered http Nmap done: 1 IP address (1 host up) scanned in 6.73 seconds Look the state of the port 80: FILTERED. I'm pretty confused now. Any suggestion would be appreciated. Thanks in advance.

    Read the article

  • Basic multicast network performance problems

    - by davedavedave
    I've been using mpong from 29west's mtools package to get some basic idea of multicast latency across various Cisco switches: 1Gb 2960G, 10Gb 4900M and 10Gb Nexus N5548P. The 1Gb is just for comparison. I have the following results for ~400 runs of mpong on each switch (sending 65536 "ping"-like messages to a receiver which then sends back -- all over multicast). Numbers are latencies measured in microseconds. Switch Average StdDev Min Max 2960 (1Gb) 109.68463 0.092816 109.4328 109.9464 4900M (10Gb) 705.52359 1.607976 703.7693 722.1514 NX 5548(10Gb) 58.563774 0.328242 57.77603 59.32207 The result for 4900M is very surprising. I've tried unicast ping and I see the 4900 has ~10us higher latency than the N5548P (average 73us vs 64us). Iperf (with no attempt to tune it) shows both 10Gb switches give me 9.4Gbps line speed. The two machines are connected to the same switch and we're not doing any multicast routing. OS is RHEL 6. 10Gb NICs are HP 10GbE PCI-E G2 Dual-port NICs (I believe they are rebranded Mellanox cards). The 4900 switch is used in a project with tight access control so I'm waiting for approval before I can access it and check the config. The other two I have full access to configure. I've looked at the Cisco document[2] detailing differences between NX-OS and IOS w.r.t multicast so I've got some ideas to try out but this isn't an area where I have much expertise. Does anyone have any idea what I should be looking at once I get access to the switch? [1] http://docwiki.cisco.com/wiki/Cisco_NX-OS/IOS_Multicast_Comparison

    Read the article

  • Using Round Robin DNS on simple VPN setup

    - by dannymcc
    We have two internet connections which are load balanced to share the load between the two. We set this up after one of the internet provider proved to be less than reliable but great speed and latency wise when it is working. We'd rather utilise both connections as much as possible rather than leave one idle until the other drops out. We have a number of remote workers who occasionally need to connect via VPN from their laptops or iPads, we also have a small number of permanent LAN to LAN tunnels running from smaller branches. Originally we only had one internet connection and used one of our static IP addresses for all VPN users. Now that we have two internet connections running all of the time I am trying to make sure that the VPN is available to our team regardless of which connection drops. So my solution is to create two A records for our domain name with a value of vpn. and the two static IP addresses from each peer. Is this a sensible way of achieving this? Should I expect higher latency due to packets being lost if one peer fails and some packets still get routed to it anyway? A brief mockup of the setup I have:

    Read the article

  • Feasibility of Windows Server 2008 DFS replication over WAN link

    - by CesarGon
    We have just set up a WAN link that connects two buildings in our organisation. The link is provided by a 100-Mbps point to point line. We have a Windows Server 2008 R2 domain controller on each side of the link. Now we are planning to set up DFS for file services across the organisation. The estimated data volume is over 2 TB, and will grow at approximately 20% annually. My idea is to set up a file server in each building and install DFS so that all the contents stay replicated over the 100-Mbps link. I hope that this will ensure that any user will be directed to the closest (and fastest) server when requesting a file from the DFS folders. My concern is whether a 100-Mbps WAN link is good enough to guarantee DFS replication. I've no experience with DFS, so any solid advice is welcome. The line is reliable (i.e. it doesn't crash often) and our data transfer tests show that a 5 MB/sec transfer rate is easily achieved. This is approximately 40% of the nominal bandwidth. I am also concerned about the latency. I mean, how long will users need to wait to see one change on one side of the link after the change has been made on the other side. My questions are: Is this link between networks a reliable infrastructure on which to set up DFS replication? What latency times would be typical (seconds, minutes, hours, days)? Would you recommend that we go for DFS in this scenario, or is there a better alternative? Many thanks.

    Read the article

  • Nagios check_host_alive and check_ping not showing host as down

    - by Kyle
    I am using the check_host_alive command to send 5 packets every minute to all my routers at remote locations. I noticed today I received a notification from The AT&T Global Client Support Center that a router was down (which can take 5-30 minutes to send these notices out) and never received a notice from Nagios. I went onto Nagios and it is was showing the host as alive with a latency of 0ms. This tells me it is seeing the automated response from my router in the data center that, "TTL expired in transit" as a reply from the remote router. Is there anyway for me to tell nagios to check where the reply is comming from? I feel like other people have to of had this issue... I tested it with the check_ping command and it produced the same results. I have the command defined has %hostname% and the proper IP in the host definition, and it works fine for telling me the latency is high. Any ideas are welcome, I have already exercised my Google skills with no results. EDIT: root@IM-UBTU:/# /usr/local/nagios/libexec/check_ping -H 192.168.250.1 -w 100.0,10% -c 200.0,20% -vvv CMD: /bin/ping -n -U -w 10 -c 5 192.168.250.1 Output: PING 192.168.250.1 (192.168.250.1) 56(84) bytes of data. Output: From 10.69.10.2 icmp_seq=1 Time to live exceeded It knows something is wrong why doesn't it give me a warning?

    Read the article

  • Bad Mumble control channel performance in KVM guest

    - by aef
    I'm running a Mumble server (Murmur) on a Debian Wheezy Beta 4 KVM guest which runs on a Debian Wheezy Beta 4 KVM hypervisor. The guest machines are attached to a bridge device on the hypervisor system through Virtio network interfaces. The Hypervisor is attached to a 100Mbit/s uplink and does IP-routing between the guest machines and the remaining Internet. In this setup we're experiencing a clearly recognizable lag between double-clicking a channel in the client and the channel joining action happening. This happens with a lot of different clients between 1.2.3 and 1.2.4 on Linux and Windows systems. Voice quality and latency seems to be completely unaffected by this. Most of the times the client's information dialog states a 16ms latency for both the voice and control channel. The deviation for the control channels mostly is a lot higher than the one of the voice channels. In some situations the control channel is displayed with a 100ms ping and about 1000 deviation. It seems the TCP performance is a problem here. We had no problems on an earlier setup which was in principle quite like the new one. We used Debian Lenny based Xen hypervisor and a soft-virtualised guest machine instead and an earlier version of the Mumble 1.2.3 series. The current murmurd --version says: 1.2.3-349-g315b5f5-2.1

    Read the article

  • What to look for in a switch with LAN/WAN verses an iSCSI SAN?

    - by Luke
    I'm setting up a VMWare ESXi 5 environment with 3 server nodes. Dell recommended 2x Force10 S60 switches shared (iSCSI SAN, LAN/WAN). The S60 switches are extremely powerful. They have 1.25 GB of buffer cache, < 9us latency. But they are very expensive (online price ~$15k per switch, actual quote a little less). I've been told that "by the book" you should at least have 2 internal switches for SAN, and 2 switches for LAN/WAN (each with a redundant). I know some of the pros and cons of each approach. What I'm wondering is, would it be more cost effective to disjoin the SAN from LAN with less expensive switches? The answer to this question highlights what I should be looking for in a switch for the SAN. What should I be looking for in a LAN/WAN switch, in comparison to the SAN? With the above linked question for the SAN: How is buffer latency measured? When you see 36 MB of buffer cache, is that shared or per port? So 36 MB would be 768kb or 36MB per port? With 3 to 6 servers how much buffer cache do you really need? What else should I be looking at? Our application will be heavily using HTML5 websockets (high number of persistent connections). The amount of data being sent is small; Data sent between client <- server isn't broadcasted (not a chat/IM service). We will be doing some database reporting too (csv export, sums, some joins). We are a small business and on a budget. We'd probably only be able to spend no more than $20k on switches total (2 or 4).

    Read the article

  • How to prevent asymmetric routing with multiple eBGP routers?

    - by Andy Shinn
    I have 2 routers announcing a /22 subnet to different providers (one providers connects to each of the 2 routers). I have split the /22 in two /23 to announce one /23 on each of the routers plus the /22 (the providers will take the more specific route). This allows me to fail over and keep traffic inside the /23 in and out the same provider. What are other ways in which I could announce just the /22 with both routers and have packets from servers on the network behind the routers go back out the same router in which they came in from? EDIT: The main problem I come across, which end users and clients complain about the most, is that the least hop route is sometimes not the "optimal" route. In my case, I know that Provider B may have better latency to X nation. But when packets come in from provider B, they may go out Provider A or provider B. The reverse is also true. If I send a packet to X nation out provider A, even though it may have more hops back, the packet will likely come in from Provider B (which may have higher latency, packet loss, etc. to this nation)

    Read the article

  • Netgear CG3000D new Modem/Router - Random High Ping

    - by justin.chmura
    Cox just recently came out and looked at my internet and decided that the modem I had was causing high latency issue. The speed was fine but the ping would spike to around 100 and over when gaming or putting a load more than browsing on the line. After they replaced it, it seems like I get better latency, but when it spikes, I get upwards of over 300 ping with like 500 jitter. I figured I would hit the serverfault universe before sending another email to Cox. I opted not to do the Cox setup as it was an extra $20 which I thought would have just setup the wireless (which I can handle). Is it a setting or something that I missed that needs to be setup? The firmware for the CG3000D is awful and not fun to use. I did change some hidden settings on the RgServices.asp page (I'll attach a screenshot). I've also heard that the Router/Modem combos are awful and that I should go back and just ask for a modem stand-alone. Any input is helpful. All screenshots: http://imgur.com/a/JX6qu#0

    Read the article

  • To what extent is size a factor in SSD performance?

    - by artif
    To what extent is the size of an SSD a factor in its performance? In my mind, correct me if I'm wrong, a bigger SSD should be, everything else being equal, faster than a smaller one. A bigger SSD would have more erase blocks and thus more leeway for the FTL (flash translation layer) to do garbage collection optimization. Also there would be more time before TRIM became necessary. I see on Wikipedia that it remarks that "The performance of the SSD can scale with the number of parallel NAND flash chips used in the device" so it seems throughput also increases significantly. Also many SSDs contain internal caches of some sort and presumably those caches are larger for correspondingly large SSDs. But supposing this effect exists, I would like a quantitative analysis. Does throughput increase linearly? How much is garbage collection impacted, if at all? Does latency stay the same? And so on. Would the performance of a 8 GB SSD be significantly different from, for example, an 80 GB SSD assuming both used high quality chips, controllers, etc? Are there any resources (webpages, research papers, presentations, books, etc) that discuss correlations between SSD performance (4 KB random write speed, latency, maximum sequential throughput, etc) and size? I realize this does not really sound like a programming question but it is relevant for what I'm working on (using flash for caching hard drive data) which does involve programming. If there is a better place to ask this question, eg a more hardware oriented site, what would that be? Something like the equivalent of stack overflow (or perhaps a forum) for in-depth questions on hardware interfaces, internals, etc would be appreciated.

    Read the article

  • Ubuntu 10.04 network manager issues

    - by Shark
    I was using the default network manager to connect to my wi-fi network, but if the connection is dropped or router restarted the network manager wont reconnect automatically after i guess a couple of tries and just gives a pop-up to connect manually . To avoid this annoyance I installed WICD but though it does try to reconnect to the network after a drop in connection it is unable to resolve the ip address and i am left with an even bigger annoyance . 1. Is there a way to counter either of these issues ? 2. Something like a background process that will check network status periodically and then try to connect to a favored network ? Edit- out put of lshw -C network *-network description: Wireless interface product: Broadcom Corporation vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:12:00.0 logical name: eth1 version: 01 serial: c0:cb:38:18:9b:7f width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=wl0 driverversion=5.60.48.36 ip=192.168.11.2 latency=0 multicast=yes wireless=IEEE 802.11 resources: irq:17 memory:fbc00000-fbc03fff *-network description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:13:00.0 logical name: eth0 version: 02 serial: f0:4d:a2:94:2d:74 size: 10MB/s capacity: 100MB/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10MB/s resources: irq:29 ioport:e000(size=256) memory:d0b10000-d0b10fff(prefetchable) memory:d0b00000-d0b0ffff(prefetchable) memory:fb200000-fb21ffff(prefetchable)

    Read the article

  • Bonnie does not provide speed for Sequential Input / Block

    - by Lqp1
    I'm using ProxmoxVE and I would like to run some benchmarks regarding performances of this product. One of these benchmarks is bonnie++ ; it runs very well in a VM (qemu-kvm) but when I run it in a conainer (openVZ), it does not provide me reading speed (only writing). I don't understand why... Does anyone know what's happenning ? VMs ans Containers are Debian 7.4. Here's the output of bonnie in the container: root@ct2:/# bonnie++ -u root Using uid:0, gid:0. Writing a byte at a time...done Writing intelligently...done Rewriting...done Reading a byte at a time...done Reading intelligently...done start 'em...done...done...done...done...done... Create files in sequential order...done. Stat files in sequential order...done. Delete files in sequential order...done. Create files in random order...done. Stat files in random order...done. Delete files in random order...done. Version 1.96 ------Sequential Output------ --Sequential Input- --Random- Concurrency 1 -Per Chr- --Block-- -Rewrite- -Per Chr- --Block-- --Seeks-- Machine Size K/sec %CP K/sec %CP K/sec %CP K/sec %CP K/sec %CP /sec %CP ct2 1G 843 99 59116 8 60351 4 4966 99 +++++ +++ 2745 8 Latency 9558us 3582ms 527ms 1672us 936us 5248us Version 1.96 ------Sequential Create------ --------Random Create-------- ct2 -Create-- --Read--- -Delete-- -Create-- --Read--- -Delete-- files /sec %CP /sec %CP /sec %CP /sec %CP /sec %CP /sec %CP 16 +++++ +++ +++++ +++ +++++ +++ +++++ +++ +++++ +++ +++++ +++ Latency 19567us 358us 368us 107us 59us 25us 1.96,1.96,ct2,1,1401810323,1G,,843,99,59116,8,60351,4,4966,99,+++++,+++,2745,8,16,,,,,+++++,+++,+++++,+++,+++++,+++,+++++,+++,+++++,+++,+++++,+++,9558us,3582ms,527ms,1672us,936us,5248us,19567us,358us,368us,107us,59us,25us The filesystem for / is of type "simfs", which is a pseudo filesystem for openVZ. Maybe it's related to this issue but I can't find anyone with the same issue with bonnie and openVZ... Thanks for your help. Regards, Thomas.

    Read the article

  • Measuring performance indicators on a cluster

    - by Aditya Singh
    My architecture is based on Amazon. A ELB load balancer balances POST requests among m1.large instances. Every instance has a nginx server on port 80 which distributes the requests to 4 python-tornado servers on backend which handle the request. These tornado servers are taking about 5 - 10ms to respond to one request but this is the internal compute time of every request. I want to put this thing on test and i want to measure the response time from ELB to upstream and back and how does it vary when the QPS throughput is increased and plot a graph of Time vs. QPS vs. Latency and other factors like CPU and Memory. Is there a software to do that or should i log everything somewhere with latency checks and then analyze the whole log to get the stuff out. I would also need to write a self-monitor which keeps checking the whole response time. Is it possible to do it with a script from within the server. If so, will it be accurate ?

    Read the article

  • Not able to connect to port different than 22 - OpenVPN

    - by t8h7gu
    I have OpenVPN network with 5 clients. Computer with Arch Linux which hosts OpenVPN server, It also hosts virtual machine with Computer with CentOS which is also connnected to OpenVPN subnet. Windows 8 which hosts virtual machine with CentOS. Both of them are connected to OpenVPN. Last one machine is virtual machine with CentOS which is hosted by computer with Ubuntu 14( which is not connected to OpenVPN. All machines in OpenVPN subnet are bolded. All phisical computers are in different networks. The problem is that when I use nmap to scan Windows and it's guest virtual machine it's saids that host seems down. When I force namp to scan specific port it shows filtered state: nmap -Pn -p 50010 n3 Starting Nmap 6.46 ( http://nmap.org ) at 2014-06-07 19:49 CEST Nmap scan report for n3 (10.8.0.3) Host is up (0.11s latency). rDNS record for 10.8.0.3: node3.com PORT STATE SERVICE 50010/tcp filtered unknown Telnet also cannot connect to this port telnet n3 50010 Trying 10.8.0.3... telnet: Unable to connect to remote host: No route to host But ss on this host show's proper state of this port ss -anp | grep 50010 LISTEN 0 50 10.8.0.3:50010 *:* users:(("java",12310,271)) What might be possible reason of that and how to fix it? EDIT I've found that I am able to connect via telnet to ssh port: telnet n3 22 Trying 10.8.0.3... Connected to n3. Escape character is '^]'. SSH-2.0-OpenSSH_5.3 So it seems that it's not problem with Windows firewall. But I have no idea what it might be. Also nmap result for first thousand ports: nmap -Pn -p 1-1000 n3 Starting Nmap 6.46 ( http://nmap.org ) at 2014-06-07 20:08 CEST Nmap scan report for n3 (10.8.0.3) Host is up (0.49s latency). rDNS record for 10.8.0.3: node3.com Not shown: 999 filtered ports PORT STATE SERVICE 22/tcp open ssh Nmap done: 1 IP address (1 host up) scanned in 77.87 seconds

    Read the article

  • What differences are there between "home" switches and "professional" switches?

    - by pjreddie
    Our radio station uses a PtP wireless system to stream our radio and TV signals from our studio up a hill to our transmitter. We have been having problems with warbly sound and drop outs that come from some point in this system. An engineer that occasionally visits the station thinks it could be the switches we use on each side of the PtP wireless system to connect the PtP devices to the encoders and decoders and wants us to get two of these switches: http://www.amazon.com/Netgear-JGS516-ProSafe-16-Port-Ethernet/dp/B0002CWPOK/ref=dp_return_1 The encoder/decoder setup only streams 8Mbps total so it seems like the switches we have should not be stressed out, unless they are causing sufficient latency to degrade the performance of the encoder/decoder. At each end of the connection we only have 4 connections, is there any reason we couldn't get a cheaper, "home" quality switch like this: http://www.amazon.com/D-Link-DGS-1005G-5-Port-Gigabit-Desktop/dp/tech-data/B003X7TRWE/ref=de_a_smtd Is there a significant difference that we would notice in terms of latency between these two switches? How much does the quality of the switch actually matter in this scenario? Any help is appreciated, feel free to ask questions if anything needs clarification. Thanks

    Read the article

  • Can not connect remotely to MySQL Server on Ubuntu 10.10

    - by BobFranz
    Ok I have searched google for two days trying to get this to work. Here are the steps I have taken so far: Clean install of Ubuntu 10.10 Install mysql 5.1 as well as admin Comment out the bind address in the config file Create a new database Create a new user that is username@% to allow remote connections Grant all access to this user to the new database EXCEPT the grant option Login on the server is ok using this new user and database on the localhost Login on the server is ok using this new user and database on the server internal network ip Login from a remote computer is ok using this new user and database using the internal network ip Login is not working when logging in with this username and database using the external ip address from the server or the remote computer. I have port forwarding enabled for this port and it is viewable from outside as confirmed by canyouseeme.org I have nmap'd using the following command on the internal ip and get the below result: nmap -PN -p 3306 192.168.1.73 Starting Nmap 5.21 ( http://nmap.org ) at 2011-02-19 13:41 PST Nmap scan report for computername-System-Name (192.168.1.73) Host is up (0.00064s latency). PORT STATE SERVICE 3306/tcp open mysql Nmap done: 1 IP address (1 host up) scanned in 0.23 seconds I have nmap'd using the following command on the internal ip and get the below result(I have hidden ip for obvious reasons): nmap -PN -p 3306 xxx.xxx.xx.xxx Starting Nmap 5.21 ( http://nmap.org ) at 2011-02-19 13:42 PST Nmap scan report for HOSTNAME (xxx.xxx.xx.xxx) Host is up (0.00056s latency). PORT STATE SERVICE 3306/tcp closed mysql Nmap done: 1 IP address (1 host up) scanned in 0.21 seconds I am completely stuck here and need some help. I have tried everything under the moon and still can not connect from a remote external ip address. Any help is greatly appreciated and I need to do anything to help find the problem let me know and I will post the results here.

    Read the article

  • Can't connect to wi-fi hotspot in Ubuntu 11.10

    - by ht3t
    I'm new to Ubuntu. I'm having a wireless network problem in Ubuntu 11.10. I made a hotspot using Connectify from a computer which is running Windows 7. I can access it in Windows 7 but not in Ubuntu 11.10. Every time I access it,I get a message "disconnected". I'm using msi fx 400 notebook with Intel Centrino wireless -N 1000 wireless card. Ubuntu version is 11.10 with KDE desktop. $ sudo lshw -c network [sudo] password for ht3t: *-network description: Wireless interface product: Centrino Wireless-N 1000 vendor: Intel Corporation physical id: 0 bus info: pci@0000:06:00.0 logical name: wlan0 version: 00 serial: 00:26:c7:56:b8:f0 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=iwlagn driverversion=3.0.0-12-generic firmware=39.31.5.1 build 35138 latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:44 memory:e7400000-e7401fff *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:07:00.0 logical name: eth0 version: 06 serial: 40:61:86:b6:b1:a2 size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl_nic/rtl8168e-2.fw IP=192.168.21.107 latency=0 link=yes multicast=yes port=MII speed=100Mbit/s resources: irq:41 ioport:9000(size=256) memory:e6004000-e6004fff memory:e6000000-e6003fff I can't do anything without internet connection. How can I fix this?

    Read the article

  • Integrating external computer into a domain - some recommendations please

    - by TomTom
    Given: * A multi loation company. Every office has local routers that connect to a central VPN capable rouer in a data center. All fine so far. We now need to move a computer off site into a hosting center across the globe, to get it closer to some supplier computers we work for. it will run limited logic but latency is important, and our latency so far is too large. This computer will be in a data center and does no require incoming connections except for adminsitrative purposes, although it needs outgoing connetions. I have no real chance to put one of my VPN routers there, sadly - otherwise I would have no problem. Usage of RRAs is not recommended (we had various probblems there over time). I could deal with it. The computer MUSt integrate into the corporate structure via VPN and join the domain and be fully "tracked" (controlled for performance). What is the best suggestion? So far it looks like my best bets woudl be to log in via RRAS and deal with whatever issues arise there plus uise the local firewall the limit incoming connections to this computer to what is needed (which runs down to an emergency RDP connection allowance). Anyone a better idea?

    Read the article

  • Where to find new Micro-BTX (uBTX) motherboards? Or should I just replace the box?

    - by John Rudy
    OK, so I'm guessing that it's dead. It's not my machine, and the owner is on a very fixed (IE, none) income. I'm generous, but I'm not that generous, since I already gave him what (at the time) was a fully functional and fairly well-equipped machine. (Aside from the mobo and proc, almost nothing else in it was stock. I'd taken it up to 3GB of RAM, upgraded the hard drive, added a decent video card, installed a wireless adapter, running Vista, etc.) According to further research, the machine uses a Micro-BTX (uBTX) motherboard, and since it's an AMD Athlon64, the AM2 socket. So I'm looking at a few options, and am wondering what's the best route to take? Find an AM2 socket uBTX mobo. I can't find them new online anywhere, leading me to believe that this is an obsolete form factor/chip combination. I don't want a refurb or a system pull because, quite honestly, once I deal with this mess, I don't want to go through it again in another year or two. Find an Intel uBTX mobo and a (relatively -- hah, I still want at least a dual-core) inexpensive Intel CPU. At this point, the only things stock in the machine would be the case and the PSU. :) Buy a bare-bones kit (mobo/proc/PSU/case, sometimes even RAM) from somewhere like CompUSA/TigerDirect or Fry's and move all of the other hardware over. This makes life difficult because the copy of Vista is an upgrade, tied to the copy of XP which shipped on the Gateway, which is OEM and won't install on the new box. :) If I change the CPU brand (AMD to Intel), will I need to reinstall Windows, or can it just be reactivated? Where can I actually find a new, in-box, not system pull, not refurb AM2 uBTX mobo? Do they even exist anymore? What kind of money are we talking (US dollars)? The end goal is to get the machine functional again as cheaply as humanly possible. If it were my own machine, I wouldn't even be asking this, I'd be custom-building a new one. However, it's not mine, I'm shelling out of pocket for the fix (plus the work), and thus want to keep that end price low-low-low.

    Read the article

  • Running out of LowMem with Ubuntu PAE Kernel and 32GB of RAM

    - by magneticMonster
    I'm running a Java data import process on a 32-bit Ubuntu 10 PAE kernel machine. After running the process for a while, the oom-killer zaps my Java process. After some Googling and digging through docs, it looks like the system is running out of LowMem. I started the process for the third time and am watching free -lm show me Low: 464 386 77 with the free value (77MB) slowly decreasing. Why am I running out of lowmem and how do I increase it? Some details: $ cat /proc/sys/vm/lowmem_reserve_ratio 256 256 32 $ free -lm total used free shared buffers cached Mem: 32086 24611 7475 0 0 24012 Low: 464 407 57 High: 31621 24204 7417 -/+ buffers/cache: 598 31487 Swap: 2047 0 2047

    Read the article

  • Remote Desktop closes with Fatal Error (Error Code: 5)

    - by Swinders
    We have one PC (Windows XP SP3) that we can not log onto using a Remote Desktop session. Logging on to the PC directly (sitting in front of it using the connected keyboard and monitor) work fine. From a second PC (tried a number of different ones but all Windows XP SP3) I run 'mstsc' and type in PC name to connect to. This shows the login box which we can enter the correct login details and click OK. Within a few second we get an error: Title: Fatal Error (Error Code:5) Error: Your Remote Desktop session is about to end. This computer might be low on virtual memory. Close your other programs, and then try connecting to the remote computer again. If the problem continues, contact your network administrator or technical support. None of the computers we are using are low on memory (2Gb+) and we let windows manage the virtual memory side of things. We do not see this with any other PC and do use Remote Desktop in meeting rooms to connect to user PCs with no problems.

    Read the article

< Previous Page | 42 43 44 45 46 47 48 49 50 51 52 53  | Next Page >